Municipal Corporation Tender
View complete overview of Chandigarh Municipal Corporation Tender
Municipal Corporation Tender
Civil And Construction
Building Construction
Eprocure
Opening Date17 Feb 2024
Closing Date26 Feb 2024
Tender Amount₹ 12,17,342
Costs
EMD
₹ 24,347Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MCC_79407_1Bid Award Id
ViewTender No
MCC/ROADS-I/2024/02-02Tender Authority
Municipal Corporation ViewPurchaser Address
-Website
http://etenders.chd.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand). DSR 6.1.1
6.21
37079
5971
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.4.1
7.74
55813
7211
Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ). DSR 5.9.4
19.52
11946
612
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) DSR 4.1.2
1.87
12083
6462
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 5.22.6
187
21505
115
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete DSR 10.2
1578.48
200467
127
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work DSR 13.61.1
102.18
11239
110
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. DSR 12.50
115.99
114018
983
Kota stone slab flooring over 20mm (average) thick base laid over slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1:4 (1 cement:4 coarse sand) 25mm thick (DSR 11.26.1)
77.32
114124
1476
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.DSR 8.31
44.05
44270
1005
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. DSR 11.32
25.61
665
26
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite stone slab colour black, Cherry/Ruby red: Area of slab over 0.50 sqm DSR 8.2.2.2
49.95
202597
4056
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge: Granite work. DSR 8.3.2
53.66
18727
349
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. DSR 16.68
91.82
61886
674
Providing and fixing PCC kerbs of size 1’-0” x 1'-0” having 4” thickness at bottom and 3” thickness at top and made of plain cement concrete 1:2:4 duly vibrated and compacted. The rates also includes fixing in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5 mm), including making drainage opening wherever required etc. complete as per direction of Engineer-in-charge. Length of finished kerb edging shall be measured for payment.
84.45
20183
239
PUBLIC HEALTH WORK
-
-
-
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil : Pipes, cables etc, exceeding 80 mm dia. but not exceeding 300 mm dia. DSR 2.10.1.2
15.43
4953
321
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter. DSR 19.1.2
15.43
8131
527
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe. DSR 19.2.2
15.43
12050
781
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter. DSR 19.21.1
1
518
518
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180 x 150 mm size P type : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 DSR 19.4.3.1
1
2286
2286
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 DSR 19.27.1
1
4711
4711
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20 mm dia nominal bore DSR 18.12.2
15.43
4382
284
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore. DSR 18.17.1A
2
1086
543
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore. DSR 18.18.2
1
403
403
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. DSR 18.48
5000
50000
10
Cutting Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour : 20 mm nominal bore, weighing not less than 40 gm . DSR 18.75.2
3
345
115
Providing and fixing brass bib cock of approved quality : 20 mm nominal bore. DSR 18.15.2
3
996
332
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) DSR 6.4.1
0.38
2737
7205
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). DSR 5.3
0.51
4423
8674
Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ). DSR 5.9.4
3.35
2050
612
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 5.22A.6
51
5865
115
ELECTRICAL WORK
-
-
-
Supply & Erection of 1x18/20 watt retrofit LED tube rod Supply & Erection of 1x18 watt retrofit LED tube rod made of aluminium housing with PC diffuser or its equivalent specification Lumen out put should be more than 100 lumens per watt (1800 LUM) with LM 79 report from NABL. The make of the fittings should be Panasonic/ Phillips/ Wipro/ Osram/ Surya/ Twinkle. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
6
6060
1010
Point wiring in PVC conduit, with modular type switch: Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulted copper conductor single core cable in surface/ recessed PVC Conduit with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. Group-C
2
1780
890
S/E of Ceiling Fans 1200mm sweep without fan regulator including M.S. pipe as per site requirement and wiring complete in all respect Make Panasonic- Captor Kraft/ Havell's/ Bajaj/ Philips/ Crompton/ Orient including making connection with 23/.076' flexible wire to be adjacent fan point with regulator. The work shall be executed to the entire satisfaction of Engineer in charge.
2
4566
2283
Supply & Erection of Exhaust Fan (450mm) 900 RPM of Panasonic/ Havell’s/ Bajaj/ Philips/ Crompton make complete with motor blades along with louver to be installed on existing hole in wall/ glazing with suitable arrangement. The rate includes cost of all labour, carriage to site, testing, commissioning of Exhaust fan & connection to existing light panel. The job shall be executed to the entire satisfaction of Engineer-in-charge.
2
12442
6221
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door Make of Panasonic, Anchor, Havells, Legrand, ABB, L&T. The work shall be executed to the entire satisfaction of Engineer in charge.
1
4615
4615
S/F’C series, SP MCB Supply and fixing 5 amps to 32 amps rating, 240 volts ‘C’ series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB Complete with connections testing and commissioning etc as required. Single pole 16 Amps “C” series Make of Anchor, Havells, Legrand, ABB, Siemens, L&T. The work shall be executed to the entire satisfaction of Engineer in charge.
4
764
191
S/F TPN MCB Supply and Fixing following rating, four pole, 415 volts, MCB TPN with box complete with connections testing and commissioning etc as required. Make of Anchor, Havell's, Legrand, ABB, L&T, Siemens, Panasonic, Schenider. The work shall be executed to the entire satisfaction of Engineer in charge. 40 Amps
1
822
822
Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
3
1128
376
Supplying and fixing suitable size G.I. box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
3
1401
467
Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminium armoured cable loose in trench/pipe:-Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminum conductor armoured cable (PVC Sheated) of make Havells/ Finolex/ Cirtina/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.1/2018 MV CB PIP-25 Part-II (External). Material Testing report to be submitted and material to be supplied at site after confirmation from Engineer-in-charge. The specification of the cable as below:- i) Conductor – Aluminum ii) Core – 4 iii) Working Voltage – 1100 V
iv) Nominal Cross Section – 16mm2 v) Minimum No. of Wire – 7/6 vi) Insulation Thickness – 1.0mm (Nominal)
vii) Inner Sheath Minimum Thickness – 0.3mm viii) Outer Sheath Minimum Thickness – 1.40mm
ix) Nominal size of Armoured Wire/Strip – 4x0.8mm x) Approximate O.D. – 22mm
Maximum d.c. Resistance at 20 Deg. C – 1.91 ohm/km
The work shall be executed to the entire satisfaction of Engineer-in-Charge.
40
9720
243
Supply & Laying of DWC pipe 51/63mm with hand bockey:- Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) With Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930/ IS 16205 part ii complete with fitting and cutting, jointing etc.direct in ground (depth as per the direction of Engineer in charge or upto 75 cm below ground level or cutting the road & laying) including excavation and refilling the trench but including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Rex, Duraline. The entire satisfaction of Engineer-in-Charge of work.
20
5360
268
PVCCON S/F PVC Conduit:
Supplying & Fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. The work shall be executed to the entire satisfaction of Engineer in charge. 25 mm
60
4860
81
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. The work shall be executed to the entire satisfaction of Engineer in charge. Make: Havell's/ Panasonic/ Polycab/ Ecko/ KEI 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
100
13200
132
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. The work shall be executed to the entire satisfaction of Engineer in charge. Make: Havell's/ Panasonic/ Polycab/ Ecko/ KEI 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
40
5760
144
S/F modular boxes, base & cover plate: Supplying and fixing following size/modules, G.I. box alongwith modular base & cover plate for modular switches Anchor/ Havell's/ Panasonic/ Philips or it's terminal equivalent make in recess etc as required.
-
-
-
8 Module (125mm x125mm)
1
405
405
S/F modular type switch/socket: Supplying and fixing following modular switch /socket on the exisiting modular plate & switch box including connections but excluding modular plate Anchor/ Havell's/ Panasonic/ Philips or it's terminal equivalent make in recess etc as required.
-
-
-
15/16 Amp switch
1
125
125
6 pin 15/16 Amp socket outlet
1
169
169
3 pin 5/6 Amp socket outlet
1
107
107
5/6 Amp switch
1
78
78
S/F Ceiling rose:
Supplying and fixing 3 pin, 5Amp ceiling rose on the existing Junction box/wooden block including connection etc as required.
4
228
57
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. Group C
2
992
496
Supplying and fixing of modular type electronics fan regulator:-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2
672
336
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements