Municipal Corporation Tender
View complete overview of Chandigarh Municipal Corporation Tender
Municipal Corporation Tender
Civil And Construction
Building Construction
Eprocure
Opening Date2 Aug 2024
Closing Date9 Aug 2024
Tender Amount₹ 6,08,836
Costs
EMD
₹ 12,177Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MCC_81614_1Bid Award Id
ViewTender No
67/E/MCC/2024Tender Authority
Municipal Corporation ViewPurchaser Address
-Website
http://http://mcchandigarh.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
3 Core 4 Sq. mm Wire
40
4560
114
Wiring for group controlled light point/ fan point/ exhaust fan point (without independent switch etc.) with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable in recessed medium class PVC conduit and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. complete as required.Make: Finolex/Polycab/Havells/KEIGroup - C
72
35712
496
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. ISI approved.
24
13440
560
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the
socket out let and complete with connections, testing and commissioning etc. as
required.
4
4696
1174
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. ISI approved.
-
-
-
25 MM
30
2430
81
32 MM
40
3280
82
Supply & laying of ISI marked 4 core 10 mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-
Supply & laying of ISI marked 4 core 10 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.1 MV CBPIP (external). The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. The specification of the cable as below:-
i) Conductor – Aluminum
ii) Core – 4
iii) Working Voltage – 1100 V
iv) Nominal Cross Section – 16mm2 v) Minimum No. of Wire – 7/6
vi) Insulation Thickness – 1.0mm (Nominal) vii) Inner Sheath Minimum Thickness – 0.3mm viii) Outer Sheath Minimum Thickness – 1.40mm ix) Nominal size of Armoured Wire/Strip – 4x0.8mm x) Approximate O.D. – 22mm Maximum d.c. Resistance at 20 Deg. C – 1.91 ohm/km The work shall be executed to the entire satisfaction of Engineer-in-Charge.
160
40480
253
Supply & Laying of DWC pipe 50/63mm with hand bockey:-
Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Gemini/Mohindra eco/Supreme. The pipe should be laid 3 feet below ground/road level with hand bockey without cutting of road for laying cables etc. including cost of digging and refilling of pits complete in all respects to the entire satisfaction of Engineer-in-Charge.
20
8380
419
Supply & Laying of DWC pipe 50/63mm with out hand bockey:-
Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Gemini/Mohindra eco/Supreme.. The pipe should be laid 3 feet below ground/road level by digging the ground upto 3 feet or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work.
110
15510
141
G.I. Earth pipe electrode with salt/ Charcoal: Supply and laying of earth electrode made out of ISI marked 'B' class G.I. pipe 4.5 Mtr. long 40 mm dia including accessories. GI pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom. The earth electrode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the engineer-in-charge.
10
25450
2545
P/F 6 SWG GI earth wire in pipe: Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
20
3660
183
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,
miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole of make L&T/Havells/Schneider/ABB Make.
22
4202
191
P/F of LED luminarie of size 2'x2' of 30-36 watt (595x595 mm) recess/ surface type including driver with system Lumens 3600-4000 Im having efficacy of minimum 100 lm/W. THD 10%, PF 0.95, Having coloured temperature 4000-6500 K recess type suitable to be fixed in Armstrong/ grid ceiling. The fitting should provides soft light and glare free symmetrical illumination and is to be fixed in the existing false ceiling frame or surface of make Havells/Surya/Bajaj/Philips/Wipro/ Twinkle alongwith connection, testing and commissioning erc. This job also includes all petty material required to be entire satisfaction of Engineer-in-charge. Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 5 years of installations.
98
305074
3113
Supply & Erection of 1x18 watt retrofit LED tube rod with Channel/batten Supply & Erection of 1x18 watt retrofit LED tube rod with Channel/batten made of aluminium housing with PC diffuser Lumen out put should be more than 100 lumens per watt (1800 LUM) with LM 79 report from NABL. The make of the fittings should be HavellsPhillips/Wipro/Surya/ Bajaj/Twinkle. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
18
15858
881
S/E of Ceiling Fans 1400mm sweep without fan regulator including M.S. pipe as per site requirement and wiring complete in all respect Make Crompton/ Usha/ Bajaj/ Khaitan/Havells including making connection with 23/.076' flexible wire to be adjacent fan point with regulator . The work shall be executed to the entire satisfaction of Engineer in charge.
12
27552
2296
Supply & erection of Exhaust Fan (heavy duty12” sweep (300mm) 900 RPM of Bajaj/Usha/Khaitan/Havells/crompton make complete with motor blades along with louver to be installed on existing hole in wall/glazing with suitable arrangement. The rate includes cost of all labour,carriage to site, testing, commissioning of Exhaust fan & connection to existing light panel. The job shall be executed to the entire satisfaction of Engineer-in-charge.
4
11168
2792
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
-
-
-
6 Module
7
1106
158
12 Module
6
1212
202
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
15/16 amps switch
14
1750
125
3 pin 5/6 amp socket outlet
12
1284
107
15/16 amps socket outlet
14
2366
169
3 pin 5/6 amp switch
34
2652
78
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
6 Module (200mmX75mm)
1
312
312
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate as per existing model switch box including connections but excluding modular plate etc.as required. ISI marked
28
9408
336
Supplying and fixing brass batten/ angle holder including connection etc. as required.
5
535
107
Supply & erection of 3 MM bakelite sheet
1200
2568
2.14
Providing and fixing three pole 250 A, 36 KA rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board
including drilling holes in cubicle panel, making connections, etc. as required. of make Havell's/ Schneider/ABB/ L&T
1
11217
11217
Providing and fixing three pole 100 A, 36 KA rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board
including drilling holes in cubicle panel, making connections, etc. as required. of make Havell's/ Schneider/ABB/ L&T
2
14922
7461
P/F of Air circulator Wall Fans of size 450 mm heavy duty of Make Crompton/ Havells/ Phillips/Bajaj/Khaitan including petty material reqd. making connection with flexible wire to be adjacent/nearest fan point. The work shall be executed to the entire satisfaction of Engineer in charge.
6
28002
4667