Municipal Corporation Tender

View complete overview of Chandigarh Municipal Corporation Tender

Municipal Corporation Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Jan 2025
Closing Soon21 Jan 2025
Tender Amount₹ 13,61,338 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply,Installation, Testing and Commissionng of good quality misting machine for water spray cooling system for wall fans including 3HP motor of make Crompton/Havells/abb/cg, MS Frame, MS Top nad water pump (8LTR/MIN) of make- Italy pulley and belt system and water filter etc. The job includes cost of abour/ installation charges and petty material required to complete the work to the entire satisfaction of Engineer-in-charge.

1

85706

85706

... More
Supply and Installation of PE pipe of size 9.5 mm outer diameter 2m thickness for wall fan misting system including labour and installation charges.The work shall be executed to the entire satisfaction of Engineer in charge.

320

116

37120

... More
Supply & Erection of 1x18 watt retrofit LED tube rod with batten Supply & Erection of 1x18 watt retrofit LED tube rod alongwith batten for housing the tube rods of make PHILIPS, Wipro, Bajaj, Havells,Twinkle. The fitting should be installed on existing surface. The job includes carriage, erection, making connections, testing and commissioning of the fitting.The cost includes all labour and material required to the entire satisfaction of Engineer-in-charge.Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations.

17

881

14977

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required.

40

106

4240

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface I recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C

40

876

35040

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
3 x 1.5 sq. mm

100

49

4900

... More
3 x 2.5 sq. Mm

200

69

13800

... More
S/F Piano type switch/socket: Supplying and fixing following piano type switch /socket on the existing switch box/cover including connections etc. as required.

-

-

-

... More
5/6Amp switch

50

38

1900

... More
3 Pin 5/6Amp socket outlet

20

50

1000

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
25 mm

180

76

13680

80

77

6160

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door

2

3484

6968

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole

36

180

6480

... More
Supply and fixing of three phase MCB TPN 63 Amp complete to the entire satisfaction of engineer-in-charge. The MCB TPN is to be fixed inside the existing Distribution Box. Make: HavellS/ Standard/ ABB.

4

2561

10244

... More
Supply and Fixing Four Pole 150 Amps ,Ics=100% , Icu at 415 V 20 KA MCCB Complete With Connections Testing and Commissioning Etc complete to the entire satisfaction of Engineer-in-charge. The MCCB is to be fixed inside the existing Distribution Box. Make: ABB/ Schneider/L&T.

1

12045

12045

... More
Supply and Erection of Three Phase Copper Bus Bar of rating 200 amp. To be fixed in main incoming panel complete in all respects.The work shall be executed to the entire satisfaction of Engineer-in-charge.

6

8010

48060

... More
Supply & laying of ISI marked 4 core 16 mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:- Supply & laying of ISI marked 4 core 16 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.1 MV CBPIP (external). The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. The specification of the cable as below:- i) Conductor – Aluminum ii) Core – 4 iii) Working Voltage – 1100 V iv) Nominal Cross Section – 16mm2 v) Minimum No. of Wire – 7/6 vi) Insulation Thickness – 1.0mm (Nominal) vii) Inner Sheath Minimum Thickness – 0.3mm viii) Outer Sheath Minimum Thickness – 1.40mm ix) Nominal size of Armoured Wire/Strip – 4x0.8mm x) Approximate O.D. – 22mm Maximum d.c. Resistance at 20 Deg. C – 1.91 ohm/km The work shall be executed to the entire satisfaction of Engineer-in-Charge.

250

295

73750

... More
Supplying and laying of following size 50/63 DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing and DWC pipe to be fixed on surface with suitable M.S. clamps etc. complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)

30

103

3090

... More
Supply & Erection of DWC pipe 50/63mm with hand bockey:- Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, anti rodent, inflammable & good weathering resistance, conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct/Gemini. The pipe should be laid 3 feet below ground/road level with hand bockey without cutting of road for laying cables etc. including cost of digging and refilling of pits complete in all respects to the entire satisfaction of Engineer-in-Charge.

50

395

19750

... More
Supply & Laying of DWC pipe 50/63mm with out hand bockey:- Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct /mini.. The pipe should be laid 3 feet below ground/road level by digging the ground upto 3 feet or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work.

200

204

40800

... More
Supply & erection of steel tubular 7.5 mtr pole 410 SP-6 conforming to IS-2713-1980, (Part-I & II) having over all length of 7.5 Meter and welded in 3 steps and having approximate Wt. 93 Kgs. with the following specifications:- a) The poll shall have cross-sectional length of 4.5, 1.5, 1.5 Mtrs. b) The outside dia and thickness shall be114.3x5.40mm, 88.9x4.85mm and 76.1x3.25mm. c.) The pole shall be erected 1.25mtrs. Below the ground level in 8” internal ready made RCC muff. d.) The gap between the pole and the muff shall be filled with the cement concrete 1:2:4.The cost includes all labour and material including carriage to the site of work. The bottom portion of the pole shall be painted with two coats of black paint after removing the dust/rust. The work shall be executed to the entire satisfaction of Engineer-in-Charge.

2

10840

21680

... More
S/E of Collars of CC Collars including following:- a) The box shall be enclosed in a cement collar made form cement concrete 1:2:4 with outside dia. 16”. b) The collar shall be embedded in the ground up to 6” shall stand 9” above ground shall have housed 10” high SMC Box and 6” top over the box. c) The collar shall be provided with 2 PVC Pipes of 40mm dia. and 45cm long to facilitate entry of cables in the Jn.Box. d)n The collar shall be plastered properly finished, curing and painted with 2 coats of snowcem of superior quality. (e) Providing and Fing Junction box of size 250x200x100mm inside dimensions of thermosetting sheet moulding compound material of robust construction with double hinge, side clamp locking arrangement, provision for MCB/Kit installatin provision alongwith connector strip of 30 amps rating suitable for minimum 4x16 sq.mm aluminium cable termination. The junction box should have two numbers PVC Glands with sufficient space for cable entry and loose wires complete in all respect to the best satisfaction of Engg.in.charge.

2

2790

5580

... More
PAINTING & NUMBERING OF POLES 4.5 Mtr. LONG - 6 M Long: - Painting of poles above ground level with two coats of Al paint of Nerolec/Asian/ICI duly approved by the Engineer-in-charge. The pole surface should be cleaned well by removing dust/rust & other depositions & smoothened with the sand paper/Iron brush & proper filling be made before painting. For numbering of poles, the base should be painted with yellow and the number should be written in black letters of 3” in length.The Cement collar around the pole should be painted with two coats of good quality white coloredsnowcem. The job includes the cost of paint of existing Junction box cover with Red paint and any other petty material require to complete the job to the entire satisfaction of Engineer-in-charge

10

180

1800

... More
G.I. Earth pipe electrode with salt/ Charcoal:-Supply and laying of earth electrode made out of ISI marked 'B' class G.I. pipe 4.5 Mtr. long 40 mm dia including accessories. GI pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom. The earth electode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the engineer-in-charge.

5

4822

24110

... More
P/F 6 SWG GI earth wire in pipe: Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required.

10

173

1730

... More
Supply and laying of insulated 2 core x 10mm2 aluminium multi conductor twin core flat unarmoured cable to fixed on the suitable clamps and nuts /bolts etc make finolex/ lapp/ polycab/ havell's or its equivalent of ISI marked. The work shall be executed to the entire satisfaction of engineer-in-charge.

350

93

32550

... More
Supply and erection of round shape bracket made out of G.I. pipe 40mm dia as per drawing i.e. inner dia of the round bracket should be 1.5 meters. The pipe ring shall be supported with four No G.I pipe supports welded at the centre with a conopy shaped pipe of size 5” dia and 0.45 mtr long to be erected on the top of the pole for supporting the fittings. The round Bracket and conopy shall be joined together in such a way that it shall give a symmetrical look. The job includes the drilling of sufficient number of holes in the bracket to erect the fittings and all material i.e. painting, grinding, welding, fabrication, drilling, nuts and boalts etc to complete the job to the entire satisfaction of Engineer-in-charge.

1

3805

3805

... More
Erection of fitting to be done in all respect to the entire satisfaction of Engineer-in-charge.

10

147

1470

... More
Supply of high power120 Watt LED Flood Light luminaries: High-brightness White LEDs sources with high transmittance LENS on each LEDs, system lumen output of system luminous efficacy of 100 lm/W, 4000 K to 6000 K color temperature & CRI70 value for ensuring good quality light output. Life of at least 50,000 hours & LED driver efficiency 95% Power factor greater than 0.90, THD15% & min 6KV surge protection with operating voltage range from 120-270 V for ensuring lifelong high performance of luminaire, having in built protection against short circuit, over voltage protection, the fixture is made of LM-6 Pressure die-cast aluminum with engraved company name & have IK05 & IP66 Class I protection with NABL Accredited LM-79 & LM-80 Report. The fixture should be comprehensively warranted to be repaired or replaced for any defect within 5 years of installations. The luminary should not be over power derived. The fitting shall be mounted on the plate bracket on existing pole including making connection, testing & energizing complete in all respect to the entire satisfaction of Engineer-in-charge. The LED Street Light Fixture shall be installed on 7.5/9 mtr long pole. The luminary should be make Philips/ Crompton/ Havells/ Surya/ Wipro/HQ Lamps.The detailed specification for supply of LED Street light luminaries is as under (with 05 years warranty). 1. Thermal Management system Good Thermal Management system Management of LED should be provided and LED must be Mounted on heat sink conductive Aluminum with suitable large area Surface by means of fins to disciple Heat to ambient air. 2. Applicable standard The fixture should confirm to Application BIS/IES standard/ IESNA LM 20.

10

4397

43970

... More
Supply Installation Testing and commissioning of 2 MP Bullet Camera with following specifications: • Image Sensor: 1/2.7” Progressve Scan CMOS • Min. Illumination: Color: 0.005 Lux @ ( F1.6, AGC ON), B/W: O Lux with IR • Shutter Time: 1/3s To 1/100, 000 s, Support slow shutter • WDR: Camera should support True WDR (120 dB) • Lens: 4mm • IR Range: Night vision IR range shall be upto 40 mtr or more • Day/Night Switch: Day, Night, Auto, Schedule • Image Enhancement: BLC, HLC, 3D DNR • Image Settings: Saturation, Brightness, Contrast, Sharpness, Gain, White Balance adjustable by client software or web browser. • Max. Resolution: 1920x1080 • Video Streams: Main Stream: 50Hz: 25fps (1920X1080, 1280X720) Second Stream: 50Hz: 25fps (640x480, 640x360, 320x240) Third Stream: 50Hz: 1fps (1280x 720) • Video Compression: H.265/H.264/H.264+/H.265+ • Region of Interest (ROI): 1 fixed regions for main stream and sub stream • Protocols: TCP/IP, ICMP, HTTP. FTP, DHCP, DNS, DDNS, RTP, RTSP, NTP, UPnP, SMTP, IGMP, 802.IX, QoS, UDP, SSL/TLS, PPPoE, ISUP • User: Up to 32 users, 3 levels: administrator, operator and user. • API: ONVIF • Basic Event: Motion detection, video tampering alarm, exception ( network disconnected, IP address conflict, illegal login, HDD full, HDD error) • Smart Event: Line crossing detection, intrusion detection • Linkage: Upload to FTP, notify surveillance center, send email, trigger capture • Communication Interface: 1 RJ45 10M/100M self- adaptive Ethernet port • Storage Conditions: -30ºC to 60ºc (-22ºF to 140ºF). Humidity 95 • Power supply: 12VDC ±25% PoE: 802.3at • Protection: IP67 • Certification: BIS/UL, CE, FCC • Make: HIKVISION,CP PLUS, HONEYWELL • Warranty: The installed CCTV cameras will be under warranty for one year. The work shall be executed to the entire satisfaction of Engineer-in-charge.

16

8411

134576

... More
Supply Installation Testing and commissioning of 16 channel Network Video Recorder with following specifications: • IP video input: 16 channel • Incoming bandwidth: 160Mbps • Outgoing bandwidth: 80Mbps • HDMI output resolution: 1-ch, 4K (4096x2160)/ 30Hz, 4K (3840x2160)/ 30Hz, 2K (2560x 1440)/ 60Hz, (1920x1080) 60Hz, (1600 x 1200)/ 60Hz,(1280x 1024)/ 60Hz, (1280x 720)/ 60Hz • VGA output resolution: 1-ch, (1920x1080) 60Hz, (1280x 1024)/ 60Hz, (1280x 720)/ 60Hz • Video output mode: HDMI/VGA simultaneous output • Audio output: 1ch, RCA • Decoding format: H.265/H.265+/H.264/H.264+/MPEG4 • Recordingresolution:8MP/6MP/5MP/4MP/3P/1080p/UXGA/720p/VGA/4CIF/DCIF/2CIF/CIF/QCIF • Synchronous playback: 16-ch • Capability: 2-ch @ 8MP (25fps)/ 5-ch @ 1080p (30fps) • Network protocols: TCP/IP, DHCP, IPv4, IPv6, DNS, DDNS, NTP, RTSP, SMTP, SNMP, NFS, iSCSI, ISUP, UPnP, HTTP, HTTPS • SATA: 2 SATA interfaces • Capacity: upto 8TB capacity for each HDD • Two- way audio: 1-ch, RCA (2.0 Vp-p, 1KΩ) • Network Interface: 1RJ-45 10/100/1000 Mpbps self-adaptive Ethernet interface • USB interface: Front panel: 1xUSB 2.0; Rear panel: 1x USB 3.0 • Working Temperature: -10ºC to 55ºc (14 to 131ºF). • Working Humidity:10 to 90% • Power supply: 12VDC • Certification: BIS/UL, CE, FCC.

1

29800

29800

... More
S/I/T/C of surveillance hard disk of 4 TB Make Seagate/ WD.

2

9810

19620

... More
S/I/T/C of 8-Ports 10/100/1000Mbps PoE + 2-Ports SFP 100/1000Mbps Layer 2 Switch, 130Watts

3

6038

18114

... More
S/I/T/C of Indoor Wall Rack 15U Approved Make : D-Link, Rittal ,President/ Comrack

1

15490

15490

... More
S/I/T/C of IP 55 Indoor Wall Rack 4U Approved Make : D-Link, Rittal ,President, Comrack

2

1448

2896

... More
S/I/T/C of Solid Cable Cat 6, 4 pair, UTP, LSZH 305m Approved Make : Panduit ,Finolex, D-Link, Molex

530

44

23320

... More
S/I/T/C of 3 Core 2.5 Sq. mm Wire make Finolex/ Havells/ Kalinga

100

69

6900

... More
S/I/T/C of COMMERCIAL LED TV 43” makes Samsung/LG/ Panasonic

1

45060

45060

... More
S/I/T/C of PVC pipe 25mm make Diplast/ Polyplast

300

76

22800

... More
S/I/T/C of 1 Kva online ups with 90 Min battery backup with Battery bank and Battery Stand with 2340VAH with Isolation make Exide/ Amaron/APC/ Emerson/Numeric.

1

74499

74499

... More
Supply and Erection of Wall Speaker 10 watt for indoor/outdoor and weather resistance for use under roof eaves. Mounting clump and hardware supply (SCM-15T 10 WATT)

8

1820

14560

... More
Supply and erection of Amplifer along with bluetooth/ AUX and also used from the phone.Make Ahuja PA Mixer Amplifier Model No. SSB/120 DP)

1

14895

14895

... More
Supply and erection of PVC wire 2 core 1sq mm copper wire 90 mtr. Roll medium for supply to speaker and amplifier. Make Ahuja

6

5000

30000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.