Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_644851_1Bid Award Id
ViewTender No
GE(AF)/CHD/T-66/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for PCC (1:2:4) type B-0 using graded crushed stone aggregates as in roof kerb or mud stops mixed with acrylic base liquid water proofing compound including all necessary formwork complete all as specified and directed. Note:-Supply only of water proofing compound shall be measured and paid for separately.
5
-
-
M&L for 75mm thick (average thickness) plain cement concrete (1:2:4) type B-1 using graded crushed stone aggregate mixed with water proofing compound as per manufacturer’s instructions as in roof padding finished the surface even and smooth without using extra cement complete all as specified and as directed. Note:- Supply only of water proofing liquid shall be measured and paid separately.
2450
-
-
M&L for rendering 10mm thick in cement mortar (1:3) mixed with liquid water proofing compound as per manufacturer’s instructions on concrete/ brick surfaces finished even and smooth without using extra cement complete all as specified and as directed. Note:- Supply only of water proofing liquid shall be measured and paid separately.
2597
-
-
M&L for water proofing treatment of roof consisting as under complete all as specified and directed:-
(a) Applying bituminous primer @ 0.30 litre per sqm over cleaned and dry roof surface including parapet. (b) Applying a coat of blown bitumen 85/ 25 grade @ 1.20 kg per sqm over priming coat of roof. (c) Providing and laying 3mm thick APP modified polyester reinforced water proofing membrane with minimum weight of 3.60 kg/ sqm as specified. The APP membrane shall be laid using torch-on application with minimum 10cm side overlap and 15cm end overlap. The APP membrane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant. The rain water gutter portion shall be finished with cement mortar (1:4) to provide requisite slope towards rain water pipe outlet. Make of APP membrane: Pidilite Industries/ STP/ IWL/ Torch Tar as approved by GE.
Note: The quoted rate by contractor shall be deemed to include necessary scaffolding and form work as required upto 15.00 Mtr high buildings.
2597
-
-
M&L for 25cm x 25cm x 22mm thick machine pressed cement concrete tiles; set jointed and pointed in neat cement slurry in floors and cut and polished with grey cement and no pigments over and including 20mm thick screed or bedding layer in cement mortar (1:4) complete all as specified and as directed.
2450
-
-
M&L for cutting out existing cracks to V-section in roofs or terracing, cleaning out, wetting, grouting with cement mortar (1:3) complete all as specified and directed.
100
-
-
Supply only liquid water proofing compound all as specified and directed.
450
-
-
Disconnecting existing water tanks of capacity exceeding 250 ltrs but not exceeding 500 ltrs, draining out of water, setting aside (or lowering if required) for repair/ cleaning and removing accumulated sludge/ dirt scales from tank bottom, side and from mouths of circulating pipes of service tanks located on roof of building and disinfecting the tank using bleaching powder to make the tank bacteria free, writing date of cleaning of tank by stencil with white synthetic enamel paint on black ground; height of words 100mm, and hoisting if required, re-fixing and reconnecting in position after cleaning complete all as specified and directed.
50
-
-
Disconnecting existing water tanks of capacity exceeding 500 ltrs but not exceeding 1000 ltrs, draining out of water, setting aside (or lowering if required) for repair/ cleaning and removing accumulated sludge/ dirt scales from tank bottom, side and from mouths of circulating pipes of service tanks located on roof of building and disinfecting the tank using bleaching powder to make the tank bacteria free, writing date of cleaning of tank by stencil with white synthetic enamel paint on black ground; height of words 100mm, and hoisting if required, re-fixing and reconnecting in position after cleaning complete all as specified and directed.
10
-
-
Supply and fixing/ hoisting, rotational moulded polyethylene (HDPE) water storage tanks (cylindrical vertical with closed top) 500 litre capacity ‘double layered’, hoisted and fixed in position including inlet, outlet and drain pipe with plug including dismantling existing tank complete all as specified and directed.
15
-
-
Supply and fixing/ hoisting, rotational moulded polyethylene (HDPE) water storage tanks (cylindrical vertical with closed top) 1000 litre capacity ‘double layered’, hoisted and fixed in position including inlet, outlet and drain pipe with plug including dismantling existing tank complete all as specified and directed.
2
-
-
S&F PTMT ball valve high pressure with epoxy coated aluminium rod and high density plastic ball, screwed suitable for 20mm borer iron pipe having minimum weight 210gms complete all as specified and as directed.
17
-
-
S&F in repairs PTMT ball valve high pressure with epoxy coated aluminium rod and high density plastic ball, screwed suitable for 20mm borer iron pipe having minimum weight 210gms complete all as specified and as directed.
12
-
-
S&F 110mm dia PVC (SWR) pipes, single socketed in any length, with rubber ring joints, fixed to wall and making good the mouth of rain water pipe in PCC (1:2:4) type B-0 using graded crushed stone aggregate including taking down old unserviceable PVC pipe and fitting etc complete all as specified and directed.
230
-
-
S&F 110mm dia PVC (SWR) bends any radius, fixed to pipes with adhesive complete all as specified and directed.
45
-
-
S&F in repairs 100mm bore of pipe stack clamps out of 50 mm x 5 mm flat iron suitable for 100mm dia pipe and 16mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roof complete in cement mortar (1:3) complete all as specified and as directed.
45
-
-
S&F galvanised steel water tubing 15mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls including clamps, concealed/ fixed on walls/ ceilings or laid in floors etc, including taking up or down the existing GI tubing complete all as specified and directed.
200
-
-
S&F galvanised steel water tubing 20mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls including clamps, concealed/ fixed on walls/ ceilings or laid in floors etc, including taking up or down the existing GI tubing complete all as specified and directed.
300
-
-
Taking up or down the existing GI water tubing 15mm bore medium grade and re-fixing in same or other location using new fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls including clamps, concealed in walls/ ceilings or laid in floors etc. complete all as specified and directed.
100
-
-
Taking up or down the existing GI water tubing 20mm bore medium grade and re-fixing in same or other location using new fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls including clamps, concealed in walls/ ceilings or laid in floors etc. complete all as specified and directed.
80
-
-
M&L for uprooting completely natural vegetation/ plants, stems of trees (upto 30cm girth) grown up on walls, parapets or in roof and making good the damaged/ disturbed portion and filling holes in cement mortar (1:3) or PCC (1:2:4) type B-0 using graded crushed stone aggregate to match with the existing surface complete all as specified directed.
50
-
-
M&L for brick work with old size sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6) in and including demolition of brick masonry built in cement mortar including all quions, arches, pillars etc. but excluding ashlars facings, dressed stone work, precast concrete articles and disposing off the rubbish debris to place as approved by civic body complete all as specified and directed.
28
-
-
All as per item No. 25.00 above but except bricks.
Note: Old re-usable bricks retrieved from dismantling shall be re-used after cleaning etc. and quoted rate shall be deemed to include for the same.
14
-
-
Taking down cement plaster on brick or stone walls or concrete surfaces etc. of any description including raking out joints, hacking for key, scrubbing down with water etc. and removal of rubbish to as place as marked by civic body complete all as specified and directed. Note: The rate quoted by contractor shall be deemed to include for necessary scaffolding and formwork as required upto 15.00 Metre high buildings.
1050
-
-
M&L for rendering 15mm thick in cement mortar (1:4) on brick or concrete surface finished even and smooth without using extra cement, complete all as specified and directed. Notes: 1. The quoted rate shall be deemed to include for necessary scaffolding and form work as required upto 15.00m high building. 2. No extra payment made to contractor for work in small patches as required at site/as directed.
650
-
-
M&L for rendering 10mm thick in cement mortar (1:3) mixed with WPC as per manufacturer's instructions @ 3% by weight of cement as on concrete surfaces (such as top & sides of chajjas, beams, balcony ceiling etc.) and finishing the surface even and smooth without using extra cement complete all as specified and directed. (WPC shall be measured and paid separately). Note: The rate quoted by contractor shall be deemed to include for necessary scaffolding and formwork as required upto 15.00 Metre high buildings.
150
-
-
M&L for rendering 15mm thick in cement mortar (1:6) on brick or concrete surface finished even and smooth without using extra cement, complete all as specified and directed.
Notes: 1. The quoted rate shall be deemed to include for necessary scaffolding and form work as required upto 158.00m high building. 2. No extra payment made to contractor for work in small patches as required at site/as directed.
250
-
-
M&L for roughening of surfaces of old concrete slab by wire brushing, sweeping, cleaning and washing down to removal all loose dust etc. and brushing neat cement slurry @ 3.00 kg/Sqm on roof surfaces complete all as specified and directed. Note: The rate quoted by contractor shall be deemed to include for necessary scaffolding and formwork as required upto 15.00 Metre high buildings.
80
-
-
M&L for raking out joints of old cement concrete tiles/ brick tiles built in cement mortar, laid on roof average 10mm deep and cleaning with wire brush and re-grouting and flush pointing the joints in cement mortar (1:3) mixed with 5% crude oil by weight of cement to make it leak proof complete all as specified. Note: The rate quoted by contractor shall be deemed to include for necessary scaffolding and formwork as required upto 15.00 Metre high buildings.
8
-
-
M&L for preparation of new wall surface plastered or un-plastered and applying two coats of cement base paint complete all as specified and directed.
Note: The rate quoted by contractor shall be deemed to include for necessary scaffolding and formwork as required upto 15.00 Metre high buildings.
770
-
-
M&L for complete removal of existing surfaces of old painted walls & applying two coats of cement base paint all as specified. Note: The rate quoted by contractor shall be deemed to include for necessary scaffolding and formwork as required upto 15.00 Metre high buildings.
1200
-
-
M&L for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty complete all as specified and directed. Make of wall care putty: JK PUTTY/ BIRLA PUTTY/ ASIAN PUTTY.
250
-
-
M&L for applying three coats of white wash on ceilings including preparation of newly plastered surfaces complete all as specified and directed.
30
-
-
M&L preparation of old treated steel surface of any description not otherwise described over 10cm girth or width and applying one coat of synthetic enamel paint complete all as specified and directed. Note: The rate quoted by contractor shall be deemed to include for necessary scaffolding and formwork as required upto 15.00 Metre high buildings.
500
-
-
S&F in repairs gun-metal, globe or gate valves with iron wheel head, screwed both ends for 15mm bore iron pipe complete all as specified and as directed.
5
-
-
S&F in repairs gun-metal, globe or gate valves with iron wheel head, screwed both ends for 20mm bore iron pipe complete all as specified and as directed.
10
-
-
S&F in repairs 1mm mild steel, plain, black sheet in hearths, covering to door shutters, covering to door chowkats (frames), chullah hoods, water tanks, water troughs, ducts, urinal troughs and funnels etc. cut to size, edges beaded if directed, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required, complete all as specified and directed.
15
-
-
S&F framed work as in doors/ chowkhats or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing in and including dismantling structural steel work including doors, gates ,post etc but excluding framed truss etc. ,complete all as specified and directed
475
-
-
M&L reinforced cement concrete (1:1½:3) type A-1 (using 20mm graded crushed stone aggregates) as in lintel beams, roof beams, lintel bands, chajjas and the like including drilling into exsting RCC work and inserting/embedding TMT bar in Old RCC work and binding with existing reinforcment of beam/column/chajja etc of any type in and including demolition of cement concrete (reinforced) (reinforcement cut as required to facilitate demolition) of any description and in any position (below or above ground level), any thickness and any length, including removal of rubbish outside MoD land upto 15 metre building height complete all as specified and directed.complete all as specified and directed.
1.5
-
-
S&F mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending etc. and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
230
-
-
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels beam, lintel bands, cantilevers, shelves, tank platform, chajja, balconies, facia including supports, overhangs, etc. also splays between floors and beams, etc with flat rough finished surfaces of concrete, complete all as specified and directed.
25
-
-
M&L welding in repairs exceeding 2.5cm but not exceeding 5.00cm in length and thickness of metal to be welded not exceeding 6mm including cleaning, preparing the surfaces and holding the member in true position for maintenance of steel items such as gates, grills, doors, window etc. complete all as specified and directed.
35
-
-
S&F Pre-painted galvalume aluminium zink coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength 550Mpa as in roof covering fixed with self tapping screws as per manufacturer’s instruction in and including dismantling plain or corrugated steel/ fibre sheeting any gauge and thickness including Nainital or similar pattern roof covering all as specified and directed.
40
-
-
S&F fibre glass reinforced translucent corrugated sheeting 2mm thick fixed with coach screws and washers with two corrugations side lap as in roof, wall etc. in and including dismantling plain or corrugated steel/ fibre sheeting any gauge and thickness including Nainital or similar pattern roof covering all as specified and directed.
30
-
-
M&L for preparation of new surfaces of steel of any description, not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
30
-
-