Military Engineer Services Tender
View complete overview of Chandigarh MES Tender
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Feb 2025
Closing Date5 Mar 2025
Tender Amount₹ 35,00,000
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_697824_1Tender No
GE(AF)/CHD/T-55/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply only constant current LED driver 60 watts IP 65 of following specifications:-
(a) Operating voltage Range- V (in) 100 to 265 Volts AC.
(b) Frequency- 50/ 60 Hz.
(c) PF- 0.98.
(d) V out- 30 to 42 V DC.
(e) I out- 350 mA.
35
-
-
... More
Supply only constant current LED driver 90 watts IP 65 of following specifications:-
(a) Operating voltage Range- V (in) 120 to 277 Volts AC.
(b) Frequency- 50/ 60 Hz.
(c) PF- 0.98.
(d) V out- 64 to 143 V DC.
(e) I out- 700 mA.
120
-
-
... More
Supply only constant current LED driver 120/ 150 watts IP 65 of following specifications:-
(a) Operating voltage Range- V (in) 120 to 277 Volts AC.
(b) Frequency- 50/ 60 Hz.
(c) PF- 0.98.
(d) V out- 64 to 140 V DC.
(e) I out- 1050 mA.
40
-
-
... More
Supply only constant current LED driver 200 watts IP 65 of following specifications:-
(a) Operating voltage Range- V (in) 198 to 264 Volts AC.
(b) Frequency- 50/ 60 Hz.
(c) PF- 0.98.
(d) V out- 71 to 21 V DC.
(e) I out- 2800 mA.
30
-
-
... More
LED surge protection device having maximum discharge surge current (Imax)- 10kA (8/20 µs), Nominal discharge surge current (In)- 5kA (8/20 µs) and protection level (Up) upto 5KV upto 200 watt security light/ flood light fitting fixe d as as in replacment , complete all as specified and directed by Engineer-in- Charge.
120
-
-
... More
Energy saving LED street light 60 watt capacity high pressure die cast aluminium housing with seal toughened glass cover, light source should be multi LED SMD array with individual secondary lenses, colour temperature 6000K, 500(±) system efficiency should be minimum 100 lumen/ watt and minimum system lumen package of 6000 lumen as LM 79 operating voltage range 120-180 volts IP-66 THD less than 10%, surge protection minimum 5 KV with flash indication, driver should be potted/ CE certified/ R certified and driver efficiency 85% including making connection fixed as as in replacment , complete all as specified and directed by Engineer-in- Charge.
25
-
-
... More
Energy saving LED street light 90 watt capacity high pressure die cast aluminium housing with seal toughened glass cover, light source should be multi LED SMD array with individual secondary lenses, colour temperature 9000K, 500(±) system efficiency should be minimum 100 lumen/ watt and minimum system lumen package of 6000 lumen as LM 79 operating voltage range 120-180 volts IP-66 THD less than 10%, surge protection minimum 5 KV with flash indication, driver should be potted/ CE certified/ R certified and driver efficiency 85% including making connection fixed as as in replacment , complete all as specified and directed by Engineer-in- Charge.
70
-
-
... More
Energy saving LED flood light 50 watt capacity high pressure die cast aluminium housing with seal toughened glass cover, light source should be multi LED SMD array with individual secondary lenses, colour temperature 5000K, 500(±) system efficiency should be minimum 110 lumen/ watt and minimum system lumen package of 5000 lumen as LM 79 operating voltage range 120-180 volts IP-66 THD less than 10%, surge protection minimum 5 KV with flash indication, driver should be potted/ CE certified/ R certified and driver efficiency 85% including making connection fixed as as in replacment , complete all as specified and directed by Engineer-in- Charge.
22
-
-
... More
Energy saving LED flood light 200 watt capacity high pressure die cast aluminium housing with seal toughened glass cover, light source should be multi LED SMD array with individual secondary lenses, colour temperature 6000K, 500(±) system efficiency should be minimum 110 lumen/ watt and minimum system lumen package of 6000 lumen as LM 79 operating voltage range 120-180 volts IP-66 THD less than 10%, surge protection minimum 5 KV with flash indication, driver should be potted/ CE certified/ R certified and driver efficiency 85% including making connection fixed as as in replacment , complete all as specified and directed by Engineer-in- Charge.
27
-
-
... More
Flat twin core10sqmm heavy duty cable 1100 volts grade PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire including taking down existing cable , complete all as specified and directed by Engineer-in- Charge.
500
-
-
... More
LT electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 35 sqmm cross sectional area, 3.5 core ,laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing in and including taking out unserviceable cable of any size from trenches, pipes, on pole, etc., , complete all as specified and directed by Engineer-in- Charge. Note : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
970
-
-
... More
All as per item No 13 here-in-before but size 25 sqmm 3.5 core , complete all as specified and as directed by Engineer-in- Charge. .
150
-
-
... More
All as per item No 13 here-in-before but size 25 sqmm 4.0 core , complete all as specified and as directed by Engineer-in- Charge. .
650
-
-
... More
All as per item No 13 here-in-before but size 16 sqmm 4.0 core , complete all as specified and as directed by Engineer-in- Charge. .
100
-
-
... More
All as per item No 13 here-in-before but size 10 sqmm 2.0 core , complete all as specified and as directed by Engineer-in- Charge. .
100
-
-
... More
Steel water tubing, 40 mm bore light grade ISI marked galvanized with all fittings laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc fixed as in replacment of old unservicable pipe,compllete all as specified and as directed by Engineer-in-Charge.
30
-
-
... More
Water proof ABS electric distribution box, weather proof IP-65 protection suitable for outdoor use, pole mounted, factory made of size 300mm x 250mm x 150mm comprising one No. MCB SP 6 Amps, 240 volts TPN bus bar not less than 25mm x 5mm aluminium strip and fixing clamps of size 25mm x 5mm two nos including necessary nuts, bolts and locking arrangement with lock, pressure type, four Nos connection holes in each bus bar with nuts, bolts and washers made of galvanized iron and connection thimble etc. fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
30
-
-
... More
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding techique and necessary machine including HDPE pipe of up to 150mm dia suitable for 0.4 mpa working pressure , complete all as specified and directed by Engineer-in- Charge.
15
-
-
... More
Excavation in trenches in any type of soil n. exc. 1.5m deep and n. exc. 1.5m in width and getting out including forming bottom surface to required slope/ gradient for laying cables/ pipes etc. , complete all as specified and directed by Engineer-in- Charge. Notes: (i) Excavation shall be done carefully to avoid damage of existing cables and protection covers.
(ii) Excavation work may be got carried out in short lengths for locating fault in underground cables at different locations.
294
-
-
... More
Excavation in trenches in any type of soil exc. 1.50 m deep and n. exc. 3.0 m in width and getting out including forming bottom surface to required slope/ gradient for laying cables/ pipes etc. , complete all as specified and directed by Engineer-in- Charge. Notes: (i) Excavation shall be done carefully to avoid damage of existing cables and protection covers.
(ii) Excavation work may be got carried out in short lengths for locating fault in underground cables at different locations.
2
-
-
... More
Returning filling in excavated soil including spreading, levelling, watering and well ramming in layers, each layer not exceeding 25mm thick in soft/ loose soil , complete all as specified and directed by Engineer-in- Charge.
167
-
-
... More
Removing excavated spoil n. exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point , complete all as specified and directed by Engineer-in- Charge.
131
-
-
... More
Sand cushioning to under ground cable with clean dry river sand in layer of sand 8cm thick before laying of cable and 15 cm after laying of cable, complete all as specified and directed by Engineer-in-Charge.
Note- For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR Part-I.
99
-
-
... More
Protection of cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks, complete all as specified and as directed by Engineer-in-Charge.
11770
-
-
... More
Preparation old painted surfaces of LT steel poles 9.00m long and painting applying one coat of synthetic enamel paint in 30cm wide strips alternate in black and yellow colour upto 1.5 mtr height above muff and the remaining portion with one coat of aluminium paint and writing pole no on pole with white paint , complete all as specified and as directed by Engineer-in-Charge.
100
-
-
... More
Aluminium cable lugs suitable for 10 Sqmm to 25 Sqmm size cable fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
100
-
-
... More
Aluminium cable lugs suitable for 35 Sqmm to 50 Sqmm size cable fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
100
-
-
... More
Bollard light pressure die cast powder coated housing with PC diffuser efficient high output LED with IP65 protection including PCC foundation of suitable size fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
20
-
-
... More
Post of lartern for 360 degree indirect light with IP65 protection, resistant to impact and corrosion, glarefare fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
12
-
-
... More
Sub main wiring with single core 2.5 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including 32 mm dia rigid non metallic PVC conduit and conduit accessories including one single core 2.5 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully wiring for security light connection from junction box to security light in and including taking down old unservicable wiring,complete all as specified and directed by Engineer-in-Charge. Note : (i) 1 run of 2.5 Sqmm ,1 run of PVC conduit & 1 run of 2.5 Sqmm cable will be measured as single run.
(ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
400
-
-
... More
Street light bracket made out of 40mm dia medium grade GI tubing 1.5 m long , fabricated to required shape and angle as per site requirement with and including MS clamps sizee 30mm x 6mm with nuts, bolts, washers etc fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
20
-
-
... More
MCCB four pole, 63 Amps, 415 volts, 16kA breaking capacity with adjustable thermal setting having Ics= 100% Icu including commissioning and testing in and including taking down the existing one ,complete all as specified and directed by Engineer-in- Charge.
8
-
-
... More
MCCB four pole, 100 Amps, 415 volts, 25kA breaking capacity with adjustable thermal setting having Ics = 75% Icu in and including taking down the existing one , complete all as specified and directed by Engineer-in- Charge.
4
-
-
... More
MCB, SPN, 230V, 6 Amps AC, 10 KA, 'C' series and 50Hz including commissioning and testing in and including taking down the existing one ,complete all as specified and directed by Engineer-in- Charge.
14
-
-
... More
MCB, SPN, 230V, 6 to 32 Amps AC, 10 KA, 'C' series and 50Hz including commissioning and testing in and including taking down the existing one ,complete all as specified and directed by Engineer-in- Charge.
4
-
-
... More
Door hinges and door locks of LT panel board/ feeder pillar box of any size any description including scrubbing/ scratching of old rusted paint by burning through blow lamps and painting the complete of LT panel board/ feeder pillar box externally and internally with 02 coats of approved colour superior quality synthetic enamel paint over a coat of red oxide primer fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
10
-
-
... More
Site clearance including cutting of grass/ trimming of all bushes/ small trees upto a height of 10 feet in surrounding areas of perimeter security lights, E/M installations, panels, bus bar chambers etc. including sprinkling of herbicide solution as per manufacturer's instructions , complete all as specified and directed by Engineer-in- Charge.
600
-
-
... More
Earthing complete with galvanised steel earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to galvanised iron strip of size 25mm x 4mm by means of bolts, nut check nuts and washers earth strip protected by galvanized steel pipe 40mm bore (light grade) connected to test point all as shown in electrical plate No. 3 of SSR 2009 (Part-I) and including necessary excavation and earth work in any type of soil, 20mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1;2:4), type B-1 reinforced XPM of weight not less than 4 Kg/ Sqm and MS frame etc. complete & connected to earthing test point all as specified or indicated including brazing/ testing on completion in and including taking down old unservicable earthing , complete all as specified and directed by Engineer-in- Charge. Notes:-
(i) The unit rate includes galvanised Iron strip and protection pipe upto (maximum 7.5m from earth plate) earth point/ test point.Qty required beyond 7.5 mtrs shall be measured and paid separaely under respective item.
(ii) Excavation & earth work, PCC pit and cover , funnel with wire mesh , 20 mm dia watering pipe , test point terminal and 40 mm dia GI protetion pipe shall be included in the quoted rate of above item nothing extra will be admissible (iii) The complete earth system shall be guaranteed to give result less than 2 ohm resistance.
(iv) Complete earthing will be redone at no extra cost to department, if result is not found less than 3 ohm.
14
-
-
... More
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25 x 4 mm thickness GI strip ,complete all as specified and directed by Engineer-in- Charge.
10
-
-
... More
LED flood light fittings of 250 watt made up of pressure die cast aluminium housing with toughened glass and high power LED's and secondary lenses with IP 66 protection; system efficiency 110/ 125/ 135 LPW, 10 KV SPD fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge.
20
-
-
... More
Light sensitve control unit for street light control panel as pole/wall mounted enclouser consisting of natural switch power contractor rating of 40 Amps (AC3) and 63 Amps MCB and terminal blocks. The enclosure comes complete with mounting bracket on wall /pole with clamps, openable door with lock and key. The enclousure shall be made of UV stablized FR grade special moulding compound to provide a rust proof, electric shock proof, termite proof outdoor mountable electrically insulating body capable of enduring solar radiation in the outdoor fixed as in replacment ,complete all as specified and directed by Engineer-in- Charge. .
Specification of light sensitive control unit shall be as under: (i) Operating Voltage : 230 Volt 50 Hz + 20% (ii) Switching Endurance : Minium 5000 Cycles (iii) Operating illuminume levels : (a) For switching ON - 60 Lux for 30Sec (b) For Switching OFF - 10 Lux for 30 Sec (iv) Auto voltage Trip levels : (a) High Volatge Trip /Auto reset : 285 VAC,270 VAC (b) Low Voltage Trip /Auto reset : 150 VAC,165 VAC (v) Oprating state indication : Through LED (vi) Duration based Switch OFF option : 04 to 08 Hrs With a resolution of ½ hour
(vii) Over ride option : Control ON and Control OFF
Make SWADEEP Model SWADEEP-02EC12kW3P or equivalent in performance in make L&T/ GE Lighting / Indoasian as approved by GE or makes as mentioned in Appendix of Makes .
3
-
-
... More
Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete swan neck type with cast iron base plate, final, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D-2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block /coping etc including finishing the exposed surfraces even and smooth without using extra cement and necssary form work, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint in and inclusing taking down of old unservicable pole ,complete all as specified and as directed by Engineer in charge.
Notes : (i) Cost of Transportation of Pole at location shall deemed to be included in the rate quoted by contractor against this item and nothing extra shall be admissible on this account .
(ii) Quoted rate of this item is deemed to inclusive cost of all the itmes mentioned therein such as earth work, PCC ,Form work ,finishes including painting etc and nothing extra shall be admissible on this account .
11
-
-
... More
Hot dip galvanised Octagonal pole 7 metre long ,top dia 70 mm, bottom dia 130mnm having sheet thickness 3 mm , base plate 200mmx200mmx12 xx (LxBxT) including foundation bolt of size 4x20 mm dia ,200 mm pitch circle dia, 600 mm bolt length, 100 mm projected bolt length, having door opening of size 90x500 mm above GL and having hot dip galvansied single arm plane bracket 1000 mm long for pole having top 70 mm dia for mounting street light fitting fixed on top with nut ,bolts and washersetc including provision of cable 2.5 sqmm, 3 core and cable connector for three phase supply and one no MCB SP of 0.6 Amp to 6 Amp including necessary excavation and earth work including disposal of surplus soil to a distance not exceeding 50 m, PCC 1:3:6 type C-1 and iron works complete all as per the instructions of the manufacturer in and including taking down of old unservicable pole ,complete all as specified and as directed by Engineer in charge.
Make : Bajaj Model No. BOP-7030 or equivalent make of Surya/HPL or makes mentioned in Appendix of Makes as approved by GE .
Notes : (i) Cost of Transportation of Pole at location shall deemed to be included in the rate quoted by contractor against this item and nothing extra shall be admissible on this account .
(ii) Quoted rate of this item is deemed to inclusive cost of all the itmes mentioned therein such as earth work, PCC ,Iron work etc etc and nothing extra shall be admissible on this account .
10
-
-
... More
Supply, installation, connecting, testing and commissioning in replacement of LT cubical panel (CPRI Approved) of suitable size factory made, compartment type, dust and vermin proof (IP-65) duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm MS Sheet on 50mm X 50mm X 6mm angle iron frame, 120 cm long angle iron legs for grouting in floor with cement concrete PCC foundation of suitable size in 1:2:4 and front & rear double door type inclusive locking arrangement & two coat of supper enameled first grade quality over red oxide primer with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable all as specified in and including taking down of old unservicable LT panel ,complete all as specified and as directed by Engineer in charge.and comprising the following:- (a) LT bus bar aluminum 400 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on insulators=1 Set Incomer : (b) Digital MCCB AC, 4 pole, 200 Amps,25 KA, 50 Hz, 415 Volts with Micro processcessor release capacity (ICs=75% of ICu)=01 No. Outgoing : (c) Digital MCCB AC, 4 pole,100 Amps,16 KA, 50 Hz, 415 Volts with Micro processcessor release capacity (ICs = 100% of ICu)= 03 Nos. (d) Digital MCCB AC, 4 pole,63 Amps,10 KA, 50 Hz, 415 Volts with Micro processcessor release capacity (ICs = 100% of ICu)= 01 Nos (e) Digital LED Amps meter with CT’s 400/5 amps and selector switch=01 Set.
(f) Digital LED Voltmeter 0-500 volts with selector switch =1Set.
(g) Phase indicator lamps RYB =01 Set (h) Internal connections with colour code copper cable multistranded of suitable size copper thimbles etc as per manufacturers design and spec. (j) Danger notice plate 440 V with conventional skull and bones in red signal colour-01No (k) Spare space for mounting MCCB-01 No
2
-
-
... More
Supply, installation, connecting, testing and commissioning in replacement of LT cubical panel (CPRI Approved) of suitable size factory made, compartment type, dust and vermin proof (IP-65) duly powder coated outdoor type suitable for 1100 volts grade, 3 phase, 4 wire supply, floor mounted fabricated out 3.15 mm MS Sheet on 50mm X 50mm X 6mm angle iron frame, 120 cm long angle iron legs for grouting in floor with cement concrete PCC foundation of suitable size in 1:2:4 and front & rear double door type inclusive locking arrangement & two coat of supper enameled first grade quality over red oxide primer with provision of all incoming/outgoing cable entries along with suitable size of double compression type cable gland for incomming & out going cable in and including taking down of old unservicable LT panel ,complete all as specified and as directed by Engineer in charge.and comprising the following:- (a) LT bus bar aluminum 400 Amps, 4 strips, duly sleeved with relevant colored insulation heavy duly mounted on insulators =1 Set Incomer :(b) Digital MCCB AC, 4 pole, 400 Amps,25 KA, 50 Hz, 415 Volts with Micro processcessor release capacity (ICs = 75% of ICu)= 01 No. Outgoing : (c )Digital MCCB AC, 4 pole,160 Amps,16 KA, 50 Hz, 415 Volts with Micro processcessor release capacity (ICs = 100% of ICu)= 03 Nos. (d )Digital MCCB AC, 4 pole, 100 Amps,10 KA, 50 Hz, 415 Volts with Micro processcessor release capacity (ICs = 100% of ICu)= 01 Nos (e) Digital LED Amps meter with CT’s 400/5 amps and selector switch=01 Set.
(f) Digital LED Voltmeter 0-500 volts with selector switch =1Set.
(g) Phase indicator lamps RYB =01 Set (h) Internal connections with colour code copper cable multistranded of suitable size copper thimbles etc as per manufacturers design and spec. (j) Danger notice plate 440 V with conventional skull and bones in red signal colour - 01 No (k) Spare space for mounting MCCB-01 No
2
-
-
... More
Energy saving rectangular LED flood light fitting 150 Watts, 240 volts AC, cool white colour, CCT 5700°K, CRI70, THD10%, system lumens not less than 100lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories fixed as as in replacment , complete all as specified and directed by Engineer-in- Charge.
15
-
-
... More
Energy saving rectangular LED flood light fitting 250 Watts, 240 volts AC, cool white colour, CCT 5700°K, CRI70, THD10%, system lumens not less than 100lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories fixed as as in replacment , complete all as specified and directed by Engineer-in- Charge.
16
-
-
... More
Energy saving rectangular LED flood light fitting 400 Watts, 240 volts AC, cool white colour, CCT 5700°K, CRI70, THD10%, system lumens not less than 100lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, aluminium die cast housing, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories fixed as as in replacment , complete all as specified and directed by Engineer-in- Charge.
15
-
-
... More
Disconnecting the all connections and lowering the flood light holding arrangement of high mast tower 16 to 20 mtr height and removing bolts and nuts at the bottom with the help of crane/motor and removing the worn out /cut stainless steel GI wire unservicable pulley,shafts checknuts etc including fixing new spares,applying grease, checking and rectifying mechanical and electrical connections and re-erecting the same after making functional of all components , complete all as specified and directed by Engineer-in- Charge. Note:(i) Necessary Spares shall be measured and paid separately under relevant item/items of the schedule as supply and fixing. The rate for minor spares necessary for carryingout the repair work which are all not covered under the schedule shall also deemed to be included the quoted rate.
(ii) The rate quoted deemed to be included the rate of all manpower including technicians, crane operator etc. and all tools and plants including crane/motor required to carryout above work.
(iii) The light assembly shall also be checked twice in the contract period other than the repairing time by taking down the light assembly from top to bottom and taking up to the original position (i.e. from bottom to top) after completing the repair work if any including checking the serviceability of high mast operating mechanism.
22
-
-
... More
Reverse forward switch suitable for existing high mast light tower 15 mtr to 20 Mtr height , complete all as specified and as directed by Engineer-in- Charge. .
5
-
-
... More
Galvanised steel wire rope 8 mm dia 30 mtr long suitable for existing high mast light tower 15 mtr to 20 Mtr height , complete all as specified and as directed by Engineer-in- Charge. .
60
-
-
... More
Pulley for geared motor of suitable size for existing high mast light tower 15 mtr to 20 Mtr height , complete all as specified and as directed by Engineer-in- Charge. .
4
-
-
... More
Sprocket for geared motor of suitable size for existing high mast light tower 15 mtr to 20 Mtr height , complete all as specified and as directed by Engineer-in- Charge. .
5
-
-
... More
Pour gear box oil suitable for geared motor after cleanig all geared surface of high mast gear box including draining out of old unusable oil , complete all as specified and as directed by Engineer-in- Charge. .
15
-
-
... More
PVC insulated flexible and PVC sheathed copper cable of size 10 sqmm, 4core of 1100 volts in and including taking down existing cable , complete all as specified and directed by Engineer-in- Charge.
50
-
-
... More
LT panel board totally enclosed floor mounted outdoor type vermin proof,dust proof made out of 3.15 mm thichk MS sheet of suitable size with door locking arrangement, door rubber beading duly painted with powder coated two coats of shynetic enamel paint over a coat of red oxide primer including panel wiring necessary civil work for fixing of panel board n and including taking down of old unservicable LT panel ,complete all as specified and as directed by Engineer in charge.and comprising the following:- (a) MCCB 4 pole 63 Amps, 16 KA,415 Volts, 50Hz with adjustable thermal and magnetic setting-01 No
(b) MCB TPN 63 Amps 10KA, 415 Volts, C Curve - 02 Nos outgoing
(c) Digital voltmeter with selector switch 0-500 Volts-01 No
(d) Digital Ammeter with selector switches 0-100 Amps-01 No
(e) Indicator lamps LED type (RYB)-01 Set
(f) Complete internal wiring with suitable PVC insulated copper conductor cable including lugs and connections.
1
-
-
... More
Disconnecting all electric connections from Motor, dismantling Rewinding of 1 to 3 HP, 3 phase, 415Volt, 50 HZ, motor and taking out the defective motor to suitable workshop and taking out the complete copper windings and rewinding with super enamelled copper winding wire, varnishing, heating, replacement of ball bearings, re-assembling and fixing at site, reconnection of all electrical connections and testing, complete all as specified and directed by Engineer-in-Charge
5
-
-
... More
Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor /Outdoor type in and including disconnecting and taking down burnt joint, complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Analog time switch of 24 hours control and save energy capable of switching loads automatically as per real time and replacement of contractor MNX 32 Amps MNX A2 amps complete all as specified and directedin and including disconnecting and taking down of old unservicable time switch, complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Note :Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documentse.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%