Institute Of Microbial Technology Tender
View complete overview of Chandigarh IMT Tender
Institute Of Microbial Technology - IMT Tender
Eprocure
Opening Date27 Jul 2018
Closing Date6 Aug 2018
Tender Amount₹ 58,64,827
Costs
EMD
₹ 1,17,300Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_CSIR_13356_1Bid Award Id
ViewTender No
CSIR/IMTECH/WORKS/18-19/001Tender Authority
Institute Of Microbial Technology ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) , including filling / grouting and finishing complete as per direction of Engineer-in-charge
.
-
-
-
Size of Tile 600x600 mm
825
-
-
Providing and laying Vitrified tiles ( Double Charged ) in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622 , of approved brand & manufacturer,(Kajaria , Nitco,RAK make) in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
-
-
-
Size of Tile 600x600 mm
800
-
-
Taking out of doors, windows and clerestory windows ( steel ,wood , Aluminium) shutters including stacking within 50 metres lead:
-
-
-
of area 3.0 sqm. and below
18
-
-
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including removing of glass panes and laminated board from door shutters and disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
850
-
-
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
20
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make confirming to IS: 733 and IS :1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereever required including cleat angle, aluminium snap beeding for glazing/ panelling, C.P. Brass/ Stainless steel screws, all complete as per architectural drawings and directions of Engineer-in-charge.(Glazing and panelling to be paid for seperately).
-
-
-
for fixed portion
-
-
-
Powder coated aluminium ( of any approved colour) (minimum thickness of powder coating 50 micron)
920
-
-
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/Neoprene gasket required(Fittings shall be paid for seperately)
-
-
-
Bronze Anodised Aluminium (Anodised transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC15)
160
-
-
Powder coated aluminium ( of any approved colour) (minimum thickness of powder coating 50 micron)
200
-
-
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board confirming to IS: 12823 grade -I Type-II, in panelling fixed in aluminium doors, window shutters and partition frames with C.P. Brass/ Stainless steel screws, all complete as per architectural drawings and directions of Engineer-in-charge.
-
-
-
Pre-laminated particle board with decorative lamination on both sides
5
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc with EPDM Rubber/Neoprene gasket etc.complete as per architectural drawings and directions of Engineer-in-charge.(Cost of aluminium snap beading shall be paid in the basic item):
-
-
-
With float glass ( Saint Gobain ,Modi guard make) panes of 6.0 mm thickness.
185
-
-
Providing and fixing 100mm brass locks (best make of approved quality) (Godrej,Doorset) for aluminium doors including necessary cutting and making good etc. complete.
15
-
-
Providing and fixing mineral fibre false ceiling tiles ( Armstong make) at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be prepainted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
-
-
-
With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6)
850
-
-
Providing and fixing vertical blinds (Make: VISTA , Neha's) of different shades, combination of design complete in all respect as approved by the Engineer-in-Charge.
140
-
-
Providing & Fixing of 12 mm Plain toughened glass with DORMA Crown Series wall connecting profile (N/S version ) consisting of aluminium profiles , clamps & S.S. finish cover with all necessary accessories ,screws etc. complete in all respect as per the directions of Engineer-in-Charge.
16
-
-
Providing and fixing of framless glass door consisting of 12 mm thick clear toughned glass Dorma Make standard fittings , Patch door set with double action floor spring BTS75V and S.S finish D / H shape pull handle 450 mm x25 mm inclushive of top pivot ( PT 24) , top patch ( PT20) , bottom patch (PT10) , corner / centre lock with EPC (US10), lock keeper plate , ( all fittings of DORMA )ake) and 12 mm thick plain toughened glass (of sizes upto 4' x 8.0') complete in all respect as per the direction of Engineer-in-Charge.
35
-
-
Removal of existing P.V.C. flooring and repairing of floor complete in all respect as per the direction of Engineer-in-charge.
850
-
-
Providing and fixing of sun control film of reflective type (of Garware make).
100
-
-
Providing and fixing of Sparkle film/ decorative tape on the existing glass doors / ventilators (of 3M make) including making required pattern and letters by cutting complete in all respect as per the direction of Engineer -in- Charge .
100
-
-
Providing and laying in position cement concrete of specified grade for making the base in level for tiling in depressions etc at all levels as per the directions of Engineer-In-Charge.
-
-
-
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregateof size 6 mm to 12 mm nominal size)
3
-
-
Credit for old existing dismantled Aluminium Partition, Wooden Partition (if any), False Ceiling etc. including dismantling , labour, carrige for disposal from site complete in all respect as per the direction of Engineer-in-Charge. ( Rate should be in minus )
2000
-
-
Total of (A) CIVIL Work
-
-
-
Wiring for circuit/ submain wiring ( Ecko , Finolax , Polycab)alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit ( Diplast , Polyplast ) as required.
-
-
-
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
810
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
200
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
750
-
-
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
1 Pair
250
-
-
2 Pair
350
-
-
4 Pair
150
-
-
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
100
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess in surface / recess including cutting the wall / floor/roof and making good the same in case of recessed conduit ( Diplast , Polyplast) as required.
-
-
-
20 mm
100
-
-
25 mm
1250
-
-
Supplying and fixing following modular switch/ socket ( L&T , Legrand ) on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
5/6 A switch
200
-
-
2 way 5/6 A switch
5
-
-
15/16 A switch
30
-
-
3 pin 5/6 A socket outlet
60
-
-
6 pin 15/16 A socket outlet
30
-
-
Telephone socket outlet
50
-
-
TV antenna socket outlet
2
-
-
Bell push
6
-
-
Supplying and fixing modular blanking plate ( L&T , Legrand ) on the existing modular plate & switch box excluding modular plate as required.
30
-
-
Supplying and fixing following size/ modules, GI box ( National make )alongwith modular base & cover plate for modular switches in recess etc. as required.
-
-
-
1 or 2 Module (75 mmX75 mm)
12
-
-
3 Module (100 mmX75 mm)
4
-
-
4 Module (125 mmX75 mm)
12
-
-
6 Module (200 mmX75 mm)
18
-
-
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240V"C" curve DP MCB ( L&T , Legrand) complete with connections , testing and commissioning etc. as required.
1
-
-
Providing and fixing ceiling lights as per the direction of Engineer -in-Charge . (Make: Philips & Wipro).( Quotation enclosed)
-
-
-
Size 600x600 mm Code No. RC-375 (36 Watt)
90
-
-
COB 7 WTS philips make (7 Watt) Focus Light
10
-
-
AURA led slim downlighter philips make (15 Watt)
10
-
-
Total of (B) ELECTRICAL Work
-
-
-
Supply,Fabrication,Installation and testing of sheet metal ducts 24 G site fabrication in accordance with the approved shop drawings complete with all accessories like vanes,flanges,suspension rods , anchor bolts , GI bolts & nuts etc. complete as per the direction of Engineer-in-Charge.
100
-
-
Providing and fixing 9 mm thick plain Nitrile rubber insulation over GI ducting with the help of SR 505 ahhesive and BOPP. complete as per the direction of Engineer-in-Charge.
150
-
-
Supply,Installation ,testing and balancing of powder coated Extruded aluminium ,supply air deffusers with removable core in accordance with approved shop drawings and specification to fit in the tile size of 600 x 600m. complete as per the direction of Engineer-in-Charge.
20
-
-
Supply,Installation ,testing and balancing of powder coated Extruded aluminium ,return air deffusers with removable core in accordance with approved shop drawings and specification to fit in the tile size of 600 x 600m complete as per the direction of Engineer-in-Charge.
20
-
-
Total of (C)Air Conditioning Work
-
-
-
TOTAL: ( A+B+C)
-
-
-
( All the rates are inclusive of all taxes)
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements