Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SITC of MS C Class pipes of required lengths with all welded joints providing and fixing in position with necessary fittings like clamps, vibration isolaters, bends, elbows, tees, reducer, mating flanges & sockets etc. complete with nitrile insulation of 19 MM thickness with suitable adhesive and finaly wraping with 26 G Aluminium cladding on following nominal sizes of chilled plumbing pipes. Make : Tata/Jindal/Sail (4.1 ) 65 mm dia MS pipes

6

-

-

... More
(4.2) 80 mm dia MS pipes

6

-

-

... More
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. (5.1 ) 40 mm ( 19 mm thick insulation)

5

-

-

... More
32 mm (19 mm thick insulation)

10

-

-

... More
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified . ( L&T /ADVANCE/ AUDCO). (6.1 ) 80 mm

2

-

-

... More
(6.2 ) 65 mm

2

-

-

... More
Providing and fixing in position the industrial type pressure gauges with gun metal/brass valves (Make : H.GURU/FRISBEE)

2

-

-

... More
Providing and fixing in position the mercury-in-glass industrial type Thermometers. (Make : H.GURU/FRISBEE)

2

-

-

... More
Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supply, Installation, Testing and Commissioning of following sizes electronic, self-balancing, pressure independent type dynamic balancing valve with integrated 3 way modualating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum. ( HONEYWELL/SIEMENS MAKE ). (9.1) 65 mm

1

-

-

... More
(9.2) 40 mm

1

-

-

... More
(9.3) 32 mm

3

-

-

... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet

12

-

-

... More
SITC of GI volume control damper complete with neoprene rubber gasket, nuts, bolts, screws linkages, flanges etc. as per standard specifications. Size of GI (18 gauge ) damper shall be matching with opening of existing duct .

1.5

-

-

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. ( 12.1) Fire Damper

1.5

-

-

... More
( 12.2) Actuator

1

-

-

... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19 mm

12

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 50 mm dia nominal bore

10

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :Leader / Sant/ Zoloto ISI mark . 20 mm nominal bore

2

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated cable in the existing surface/recessed steel/ PVC conduit as required. (16.1) 3 Core , 25 SQMM copper cable , Armoured

20

-

-

... More
(16.2 ) 3 Core , 1.5 SQMM copper cable , Unarmoured

6

-

-

... More
SITC of canvas for connection of AHUs and ducts complete as per the direction of Engineer-in-Charge.

1

-

-

... More
Commissioning of 32 mm - 3 Nos, 40 mm - 1 Nos) 3 way modulating valves with actuator ( as per item no 9 -(ii) & (iii) and integrating the same with existing Siemens BMS already installed at site

1

-

-

... More
Credit for old existing dismantled AHU's of different capacity (received against above Item No.1 23800CHM/ 14000 CFM

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.