Haryana Police Housing Corporation Tender

View complete overview of Chandigarh HPHC Tender

Haryana Police Housing Corporation - HPHC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date27 Jan 2025
Closing Date6 Feb 2025
Tender Amount₹ 76,33,387 
Notes
Download

Costs

  • EMD

    ₹ 1,52,000
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 1,180

Summary

Special Repair Of Commando Barracks At Cm Residence Sector 2, Chandigarh

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
HSR 9.32 SHEET ROOFING Providing and fixing UV stabilised fibreglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated `J` or `L` hooks, bolts and nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2. 2 mm thick flat

156.6

794

124340.4

... More
HSR 9.34:- SHEET ROOFING Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm ( plus 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : 1. Ridges plain (500 - 600mm)

69.01

311

21462.11

... More
HSR 9.34:- SHEET ROOFING Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm ( plus 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : 2. Flashings/ Aprons.( Up to 600 mm)

302.79

295

89323.05

... More
HSR 4.14:- Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil.

20.28

83

1683.24

... More
HSR 9.47:- CEILING Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 4. 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with centre borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.

444.38

677

300845.26

... More
HSR 9.58:- RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 1.1. Coupler 75 mm

13

49

637

... More
HSR 9.58:- RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 2.2. Single push fit Coupler 110 mm

13

74

962

... More
HSR 9.58:- RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 3.1. Single tee with door 75x75x75 mm

13

104

1352

... More
HSR 9.58:- RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 3.2. Single tee with door 110x110x110 mm

7

155

1085

... More
HSR 9.58 :- RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 3.3. Single tee with door 150x150x150 mm

17

210

3570

... More
HSR 9.58:- RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.1. Bend 87.5° 75 mm bend

13

59

767

... More
HSR 9.58:- RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.2. Bend 87.5° 110 mm bend

13

93

1209

... More
HSR 9.58:- RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 5.3. Bend 87.5° 150 mm bend

4

129

516

... More
HSR 9.58:- RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 6.1. Shoe (Plain) 75 mm Shoe

8

50

400

... More
HSR 9.58:- RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 6.2. Shoe (Plain) 110 mm Shoe

8

79

632

... More
HSR 9.58:- RAIN WATER SPOUTS AND PIPES Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 6.3. Shoe (Plain) 150 mm Shoe

4

113

452

... More
HSR 4.19:- Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth up to 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : 1.1. Ordinary rock : Pipes, cables etc. not exceeding 80 mm dia

64.8

87

5637.6

... More
HSR 5.11:- Demolishing mud phaska in terracing and disposal of material within 50 metres lead.

30.44

185

5631.4

... More
HSR 5.14:- Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.

202.91

35

7101.85

... More
HSR 5.15:-Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: 2. Asbestos Cement sheet

507.56

20

10151.2

... More
HSR 8.26:- KITCHEN PLATEFORMS/ WINDOW SILLS/ URINAL PARTITIONS Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shade Area of slab over 0.50 sqm

2.1

2776

5829.6

... More
HSR 5.23:- Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 2. Nominal concrete 1:2:4 or leaner mix (i/c equivalent design mix)

37.07

1149

42593.43

... More
HSR 5.29:- Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 1. Of area 3 sq. metres and below

79

108

8532

... More
HSR 5.43:- Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 1. For thickness of tiles 10 mm to 25 mm

117.05

22

2575.1

... More
HSR 5.45:- Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.

225.03

33

7425.99

... More
HSR 5.49:- Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.

444.38

15

6665.7

... More
HSR 10.1:- CEMENT CONCRETE FLOORING Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. 1.1. Re-compacting excavated soil in plinth under floors, including watering, ramming, consolidating and dressing complete.

64.04

73

4674.92

... More
HSR 10.7:- CEMENT CONCRETE FLOORING Providing and laying of conglomerate floor 50mm thick cement concrete topping 1:2:4

25

216

5400

... More
HSR 10.14:- CEMENT CONCRETE FLOORING Providing a floating coat of 1.50 mm thick neat cement laid in one operation to the topping.

357.39

29

10364.31

... More
HSR 11.5:- CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix : 4. 1:6 (1 cement: 6 fine sand)

116.7

104

12136.8

... More
HSR 13.3:- STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 1.1. Profile B Fixing with adjustable lugs with split end tail to each jamb

106.9

341

36452.9

... More
HSR 11.6:- CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1. 1:4 (1 cement: 4 fine sand)

79.49

138

10969.62

... More
HSR 13.10:- STEEL DOOR/ WINDOW FRAMES AND SHUTTERS Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1. 4.0 mm thick glass panes

54.56

539

29407.84

... More
HSR 10.58:- CERAMIC GLAZED TILES Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

322.83

538

173682.54

... More
HSR 10.67:- VITRIFIED FLOOR TILES Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. complete. 2. Size of Tile 600x600 mm

265.46

1004

266521.84

... More
HSR 10.70:- VITRIFIED FLOOR TILES Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 2. Size of Tile 600x600 mm

265.46

140

37164.4

... More
HSR 13.28:- SIGLE/BUILT-UP STEEL/TUBULAR SECTIONS Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

3500

75

262500

... More
HSR 11.58:- INTERIOR FINISHING Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete

2654.38

32

84940.16

... More
HSR 11.60:- INTERIOR FINISHING Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

196.18

59

11574.62

... More
HSR 11.64:- INTERIOR FINISHING Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer

1378.86

45

62048.7

... More
HSR 10.106:- OTHER MISCELLANEOUS ITEMS USED FOR FLOORING 0 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 0 0 0

84.5

966

81627

... More
HSR 11.76:- INTERIOR FINISHING Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete.

557.87

37

20641.19

... More
HSR 11.77:- INTERIOR FINISHING Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc.

557.88

19

10599.72

... More
HSR 11.78:- INTERIOR FINISHING Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade.

557.88

31

17294.28

... More
HSR 11.95:- EXTERIOR FINISHING WALL AND ROOF SURFACES Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

1471.82

88

129520.16

... More
HSR 12.36:- FLUSH DOOR SHUTTERS Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 2. 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

45.88

2154

98825.52

... More
HSR 12.61:- COPPER OXIDISED MILD STEEL FITTINGS (COPPER OXIDISED AS PER IS: 1378) Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws etc. complete. 2. 100x58x1.90 mm

90

26

2340

... More
HSR 12.70:- COPPER OXIDISED MILD STEEL FITTINGS (COPPER OXIDISED AS PER IS: 1378) Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : 2. 115 mm

122

19

2318

... More
HSR 12.71:- COPPER OXIDISED MILD STEEL FITTINGS (COPPER OXIDISED AS PER IS: 1378) Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 3. 200 mm weighing not less than 120 gms

140

35

4900

... More
HSR 12.88:- HYDRAULIC DOOR CLOSERS Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 35 kg and door width up to 700 mm), with necessary accessories and screws etc. complete.

14

832

11648

... More
HSR 12.98:- ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 2. 250x16 mm

28

179

5012

... More
HSR 12.99:- ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 3. 200x10 mm

54

72

3888

... More
HSR 12.99:- ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 4. 150x10 mm

298

62

18476

... More
HSR 12.102:- ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1. 125 mm

312

49

15288

... More
HSR 12.103:- ANODISED ALUMINIUM FITTINGS (ALL FITTINGS SHALL BE ISI MARKED) Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 2. Twin rubber stopper

30

52

1560

... More
HSR 12.157:- C ALUMINIUM WORK Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 1.2. For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)

50

350

17500

... More
HSR 12.157 :- C ALUMINIUM WORK Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 2.2. For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)

70

403

28210

... More
HSR12.158:- C ALUMINIUM WORK Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 2. Pre-laminated particle board with decorative lamination on both sides

2.8

789

2209.2

... More
HSR 12.159:- C ALUMINIUM WORK Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 1. With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)

4.32

667

2881.44

... More
HSR22.1:- WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1. White vitreous chinaware Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

8

2027

16216

... More
HSR 22.5WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing white vitreous chinaware pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.

8

1104

8832

... More
HSR 22.10WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 2.1. Kitchen sink without drain board 610x510 mm bowl depth 200 mm

4

2620

10480

... More
HSR 22.14WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 2.1. Flexible pipe 32 mm dia

12

57

684

... More
HSR 22.22 WCs, URINALS AND URINAL PARTITIONS Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1. White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

5

3493

17465

... More
HSR 22.25:- WCs, URINALS AND URINAL PARTITIONS Providing and fixing white vitreous chinaware flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 2. One urinal basin with manually operated 5 litres PVC cistern and manually operated stop cock/ angle valve

2

2845

5690

... More
HSR 22.34 :- WCs, URINALS AND URINAL PARTITIONS Providing and fixing floor mounted, white vitreous chinaware single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous chinaware cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.

2

12200

24400

... More
HSR22.50:- WCs, URINALS AND URINAL PARTITIONS Providing and fixing partitions for different type of urinals. 1.2.1. Vitreous Chinaware Partition plate. Large size 835mm x 355 mm White

2

1178

2356

... More
HSR 7.21:- B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand)

11.62

4128

47967.36

... More
HSR 7.22 :- B BRICK WORK Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 2. Cement mortar 1:6 (1 cement : 6 coarse sand)

25.35

4488

113770.8

... More
HSR 22.86 C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes

50

264

13200

... More
HSR 22.86 C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes

20

333

6660

... More
HSR 22.86 :- C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 4. 32 mm nominal outer dia Pipes

15

429

6435

... More
HSR 22.98:- BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 1. 25 mm nominal bore

8

414

3312

... More
HSR22.98 :- BRASS FITTINGS Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 3. 32 mm nominal bore.

4

485

1940

... More
HSR22.101:- BRASS FITTINGS Providing and fixing Unplasticised PVC connection pipe with brass unions : 2.1. 45 cm length 15 mm nominal bore

39

51

1989

... More
HSR 22.103:- BRASS FITTINGS Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 2. 20 mm nominal bore

4

294

1176

... More
HSR 22.104:- C.P. BRASS FITTINGS Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore

7

346

2422

... More
HSR 22.106:- C.P. BRASS FITTINGS Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 1. 15 mm nominal bore

24

457

10968

... More
HSR22.107:- C.P. BRASS FITTINGS Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore

40

508

20320

... More
HSR 22.109 C.P. BRASS FITTINGS Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.

110

49

5390

... More
HSR 22.1117 :- PTMT FITTINGS Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.

8

127

1016

... More
HSR 22.118:- PTMT FITTINGS Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

10

167

1670

... More
HSR 22.119:- PTMT FITTINGS Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 2. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

8

360

2880

... More
HSR 22.123 PTMT FITTINGS Providing and fixing PTMT grating of approved quality and colour. 1.2. Circular type 125 mm nominal dia with 25 mm waste hole

36

38

1368

... More
HSR 30.16:- FINISHING WORKS Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 1. With cement mortar 1:4 (1 cement : 4 fine sand)

167.45

176

29471.2

... More
HSR 30.18:- FINISHING WORKS Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.

357.39

1

357.39

... More
HSR 30.22:- FINISHING WORKS Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.

2654.91

10

26549.1

... More
HSR 30.28:- FINISHING WORKS Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 1. One or more coats on old work

631.7

38

24004.6

... More
HSR 30.53:- WOOD WORKS Replacing and fixing 25 mm thick shutters for cup board etc i/c disposal of dismantled shutters, if any: 1.2. Panelled or panelled & glazed shutters : Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws.

167.45

2658

445082.1

... More
HSR 30.58:- WOOD WORKS Renewal of old putty of glass panes (length)

186

17

3162

... More
HSR 30.59:- WOOD WORKS Refixing old glass panes with putty and nails

27.28

227

6192.56

... More
HSR 30.74:- STEEL AND IRON WORKS Replacing and fixing bright finished brass casement window fasteners or peg stays to windows/ ventilators with necessary welding and machine screws etc. complete.

150

312

46800

... More
HSR 30.91:- WATER SUPPLY, SEWERAGE AND DRAINAGE WORKS Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia up to 300mm

120

92

11040

... More
HSR 22.166:- STONE WARE PIPES AND FITTINGS Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 1.1. 100x100 mm size P type With common burnt clay non-modular bricks of class designation 7.5

10

1457

14570

... More
HSR 22.179 MASONRY CHAMBERS Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 1.1. Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay non-modular bricks of class designation 7.5

8

3794

30352

... More
HSR 22.181:- LOFT AND TERRACE WATER TANKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

6000

7

42000

... More
HSR 22.210:- BATHROOM ACCESSORIES Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 2. Rectangular shape 453x357 mm

8

698

5584

... More
HSR 22.222:- HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete

120

534

64080

... More
HSR 22.222:- HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.2. Single Socket Type B 110mm o/d SWR UPVC pipe lines laid complete

20

322

6440

... More
HSR 22.222:- HDPE pipes for Drainage Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.4. Single Socket Type B 75mm o/d SWR UPVC pipe lines laid complete

20

242

4840

... More
HSR 6.1:- A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)

104.66

3975

416023.5

... More
HSR 6.1:- A CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 6. 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

14.18

2442

34627.56

... More
HSR 23.4:- COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.1. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A

200

520

104000

... More
HSR 23.4:- COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 3.1. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group A

25

225

5625

... More
HSR 23.4:- COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.1. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group A

65

725

47125

... More
HSR 23.4:- COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.1. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A

44

999

43956

... More
HSR 24.1:- EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.

6

2721

16326

... More
HSR 24.1:- EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.

6

652

3912

... More
HSR 24.1:- EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.

50

96

4800

... More
HSR 23.5:- COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm)

1500

53

79500

... More
HSR 23.5:- COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm)

1000

109

109000

... More
HSR 23.7:- PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia.

1150

32

36800

... More
HSR 23.8:- FITTING AND ACCESSORIES 10.4. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 6 Modules

110

186

20460

... More
HSR 23.8:- FITTING AND ACCESSORIES 10.6. Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 12 Modules

30

282

8460

... More
HSR 23.8:- FITTING AND ACCESSORIES 11.1. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch

108

41

4428

... More
HSR 23.8:- FITTING AND ACCESSORIES 11.3. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 1 way switch

50

82

4100

... More
HSR 23.8:- FITTING AND ACCESSORIES 11.4. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp Socket

108

82

8856

... More
HSR 23.8:- FITTING AND ACCESSORIES 11.5. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 15 amp 6 pin Socket

50

124

6200

... More
HSR 23.8:- FITTING AND ACCESSORIES 11.7. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt

39

257

10023

... More
HSR 23.8:- FITTING AND ACCESSORIES 11.10. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. Blanking plate

60

18

1080

... More
HSR 23.20:- Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required

141

67

9447

... More
HSR 23.22:- MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.4. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA

1

5249

5249

... More
HSR 23.22:- MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA

1

6695

6695

... More
HSR 23.22:- MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.3. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 12 way ( 2 incoming and 10 outgoing)

6

1706

10236

... More
HSR 23.22:- MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.9. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing)

1

6088

6088

... More
HSR 23.22:- MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole

100

145

14500

... More
HSR 23.22:- MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.2. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Single Pole

8

308

2464

... More
HSR 23.22:- MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole

8

677

5416

... More
HSR 23.24:- MS STAND, BUS BAR CHAMBER AND PANELS 3.2. Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S. sheet and fixing with rag bolts on wall or on existing pedestal/angle iron frame including bonding, detachable top and bottom including painting and necessary connection etc. (Aluminium bars). 100 amp 4 bars of 55 cm each (cross section 25 mm x6 mm) chamber over all size 60 cm x 45 cm x 18cm

1

3101

3101

... More
HSR 23.25:- DISMANTLING 1.1. Dismantling old wiring points ( surface wiring system ) including necessary repairs to wall etc. Light, fan or call bell Point including circuit/sub main wiring

250

21

5250

... More
HSR 23.25:- DISMANTLING 1.2. Dismantling old wiring points ( surface wiring system ) including necessary repairs to wall etc. Wall socket point including circuit/submain wiring

40

21

840

... More
HSR 22.106:- BATHROOM ACCESSORIES Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-in-charge. 5. 50 Litres capacity

4

12724

50896

... More
HSR 20.71:- CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48" (1200mm)

39

2054

80106

... More
HSR 20.72:- CEILING FAN/ EXHAUST FAN Supplying, errection, testing of Exhaust fan (as per IS code 374) having a capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge.

6

1339

8034

... More
HSR 24.13:- LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 13. 10 Sq mm 2 core (UnArm.)

200

89

17800

... More
HSR 24.13:- LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 30. 25 Sq mm 3.5 core (Arm.)

150

205

30750

... More
HSR 24.13:- LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 36. 35 Sq mm 3 core (Arm.)

100

228

22800

... More
Supply and fixing of 70/40mm PUF Insulated Roof Panel with 0.50mm thick corrugated profile sheet from outside and micro ribbed 0.50mm thick PPGI (Make-JSW) inside infill with fire retardent Grade PUF Density 42kg/m3 plus 5% with proper overlapping to prevent the water leakage and projections on all sides. free and ozone friendly.( Pentane Based). Installation of Roof Panels with complete hardware and silicon sealant.

733.67

2197

1611872.99

... More
Supply and erection of copper refrigerant pipe with insulation with labour etc.

15

578

8670

... More
Supply and Erection of PVC hard Drain Pipe of 25 mm dia including PVC Tee, Elbow, Etc.

15

87

1305

... More
Supply of exhaust fan 300mm sweep suitable for operation on 230 volts 50 Hz A.C supply complete in all respect.

6

2525

15150

... More
Supply and erection of RO 50 LPH with all necessary material required to complete the job in all respect. Make Aquaguard

1

40295

40295

... More
Supply and erection of water cooler fully stainless steel body with 150/ 150 litre storage capacity ISI mark with Non CFC refrigerant with all labour required to complete the job in all respect.Make Coolstar Climatrol

1

49889

49889

... More
Supply and erection of commercial Room air Cooler 125 Ltr i/c necessary material complete in all respect. Make Symphony (Movicool 125 Ltr)

30

19747

592410

... More
Supply and erection of wall fan of size 400mm complete in all respect. Make as per aproved brand list of HPHC

34

4711

160174

... More
Supply of LT unarmoured cable of following 1100 Volt and complete with making necessary connection of cable on both ends including loading, unloading and carriage with all labour and petty material required to complete the job upto the entire satisfaction of Engineer-in-Chargre of the work. 1) LT unarmoured cable of size 10sqmm 2 core

200

102

20400

... More
Supply of surface mounting LED batten fitting 1 x 18 /20 watt, (4 feet long), made of high grade polycarbonate body provided for efficient heat dissipation and Integrated electronic driver suitable for single phase A.C. 230 Volts, 50 Hz supply, complete in all respect.

89

191

16999

... More
Supply and Erection of 100 watt LED Flood light suitable for operation on 230V ,50Hz complete the job in all respect . Make as per HPHC approved brands (NS).

10

3038

30380

... More
Supply of new generation energy saving and environmental friendly long life 45/50 watt LED street light with IP-66 Protection Make havells or equivalent as per HPHC Brand list

6

2531

15186

... More
Supply of 32/34/36 watt 6000k LED Surface/recess Mount fitting, slim type, M.S body 2`x2` size suitable for operation on 230V 50Hz AC Supply Make Havells or as per HPHC approved brand list WITHOUT GST (NS).

52

2081

108212

... More
Supply and erection of FRLS, PVC insulated unsheathed single core and PVC round sheathed multicore flexible copper cable for working voltage upto and including 1100 volts to is : 694/2010 – ISI marked complete in all respect. 1) 1.5sqmm

2100

17

35700

... More
Supply and erection of FRLS, PVC insulated unsheathed single core and PVC round sheathed multicore flexible copper cable for working voltage upto and including 1100 volts to is : 694/2010 – ISI marked complete in all respect. 1) 4 sqmm

1000

38

38000

... More
SITC of 1.5 Ton inverter type 5 Star rating Split AC with suitable MS Stand for outdoor, outdoor unit with compressor gas, 3 mtr copper refrigerent pipe including all required accessories like nut bolts etc. complete with making necessary connection in all respect and as satisfaction of Engineer - in - charge.

6

43850

263100



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.