Chandigarh Industrial And Tourism Development Corporation Limited Tender
View complete overview of Chandigarh CITCO Tender
Chandigarh Industrial And Tourism Development Corporation Limited - CITCO Tender
Security and Emergency Services
Eprocure
Opening Date4 Jul 2024
Closing Date22 Jul 2024
Tender AmountRefer Documents
Costs
EMD
₹ 6,300Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Providing And Fixing Of Fire Fighting System In Citco Petrol Station Sector-9 Chandigarh
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CITCO_81037_1Tender No
CITCO/EE/2023/11Tender Authority
Chandigarh Industrial And Tourism Development Corporation Limited ViewPurchaser Address
-Website
http://https://citcochandigarh.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Steel Reinforcement For R.C.C work i/c straightening, cutting, bending placing in position and binding all complete upto plinth level.
-
-
-
Thermo-Mechanically Treated Bars of grade Fe-500D or more. (DSR No. 5.22.6)
50
4850
97
Reinforced Cement Concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size). (DSR No. 5.3)
0.45
4251
9448
Providing and fixing in position 5000 Litres Triple Layer Water Storage Tank, IS: 12701 marked with cover and suitable locking arrangement i/c making holes for inlet, outlet and overflow pipes with fittings like 25 mm brass ball cock with ball, tank nipple 25 mm at inlet, 75 mm tank nipple at outlet with flange etc. i/c cost of hoisting at a height of 12’-0” complete in all respects. (M.R)
1
77776
77776
Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required
-
-
-
25 mm dia. (DSR No. 8.1 of Wet Riser & Sprinkler system)
9
4050
450
Providing, laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 3589/ IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:
-
-
-
80 mm dia.(DSR no.7.6 of Wet Riser & Sprinkler system)
0.9
1485
1651
100 mm dia. (DSR no. 7.7 of Wet Riser & Sprinkler system)
18.25
43526
2385
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS : 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required.
-
-
-
80 mm dia. (DSR No. 14.4 of Wet Riser & Sprinkler system)
1
6600
6600
Providing, installation, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/ gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizesas required :
-
-
-
80 mm dia . (DSR No.11.4 of Wet Riser & Sprinkler system)
1
3750
3750
Providing, fixing and testing of first aid hose reel with MS construction spray painted in post office conforming to IS 884 complete complete with the following as required. a) 30 Mtr. Long 20 mm (Nominal Internal dia water hose Thermoplastic (Textile reinforced) type-2 as per IS: 12585. b) 20 mm (Nominal Internal Dia) gun metal globe valve & nozzle. c) Drum and brackets for fixing the equipments on wall. d) Connections from riser with 25mm Dia stop / ball valve (Gun Metal or Brass), M.S Pipe & including pressure reducing valve. (DSR No.17.1 of Wet Riser & Sprinkler system)
1
7285
7285
Providing and fixing of hose cabinet of Size : (600mm x 600mm x 450mm) made of 16 gauge MS sheet with 4mm thick glazed glass door i/c necessary locking arrangement suitable to accommodate 15 mtr. long hose reel pipe & branch pipe mounted on wall or raised on brick masonry platform & duly painted with Post office red externally and white internally with synthetic enamel paint complete in all respect as required. (M.R)
1
4580
4580
Supplying and fixing single headed internal hydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Stainless Steel cap and chain as required. (DSR No. 9.2 of Wet Riser & Sprinkler system))
1
5425
5425
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required. Stainless Steel (Grade 304) (DSR No. 16.2 of Wet Riser & Sprinkler system)
1
5230
5230
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous
connection to interconnect hose pipe coupling as required :
-
-
-
Stainless steel (Grade 304). (DSR No. 18.2 of Wet Riser & Sprinkler system)
1
1805
1805
Providing, fixing and Testing of 2 way fire brigade inlet connection of cast iron body with 2 No.'s, SS male instantaneous inlet coupling complete with cap and chain as required for 150 mm dia MS pipe connection, conforming to IS 904 as required.
-
-
-
2 way-100 mm dia M.S. Pipe. (DSR No. 19.1 of Wet Riser & Sprinkler system)
1
3927
3927
Providing & fixing in position Photo – Luminescent (Glow-in-Dark) signage made out of 3mm thick Acrylic sheet with Photo – Luminescent non-coated rigid polyester film reading ‘EXIT’ with Directional signage of approx. size 1’-6” x 1’-0” complete in all respects. (M.R)
2
4000
2000
Supply, Installation, Testing and commissioning of mono-block centrifugal pump-set with motor of 5 HP capacity 3 phase i/c suitable MS frame work with nuts, bolts etc. & other required electrical accessories complete in all respects. (M.R)
1
47000
47000
Providing and fixing Ball Valve of approved quality (screwed end) 25 mm nominal bore. (DSR no. 18.17.1)
2
1758
879
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 25 mm nominal bore. (DSR no. 18.46.3)
2
848
424