Chandigarh Administration Tender

View complete overview of Chandigarh Chandigarh Administration Tender

Chandigarh Administration Tender

Works
Telecommunication Services
Eprocure
Opening Date1 Mar 2024
Closing Date11 Mar 2024
Tender Amount₹ 37,57,498 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Installation, Testing and Commissioning of SFP+ 10000 Base LX Fiber Module. Make: Cisco / HPE/Juniper/Netgear only.

12

218748

18229

... More
6 PORT FIBER LIU: Supply, Installation, testing and Commissioning of 6 Port Fiber LIU which have sufficient slots to accommodate 24/12 Duplex LC/SC Ports ,Should have fiber management provision inside with splice tray and other accessories, Should be rack mountable 1U, Should have Splice holder for minimum 24 Fiber cores, Should be made of Cold Rolled Steel, Material Should steel: 1.5 mm, powder-coated The enclosure/LIU should have locks to secure all the fiber terminations & must have front cable management to properly route patch cords. Make: R&M / Siemon / Systimax / Molex only.

6

35100

5850

... More
OPTICAL FIBER PIGTAILS: Supply, Installation, testing and Commissioning of OPTICAL FIBER PIGTAILS, 1.5 MTR SM OS2. Precision ferrule end face geometry SC Type SM. Factory polished tested and serialized. Buffer Diameter: 900um tight buffer. Minimum bend radius: install: 30 mm. Retention Strength: 100N. Cable: 900um Buffered. Sheath: LSZH. Make: R&M/ Systimax/ Siemon / Molex only.

35

11760

336

... More
OFC CORDS: Supply, Installation, testing and Commissioning of OPTICAL FIBER EQUIPMENT CORDS (MINIMUM 2 METER) SC-LC /SC -SC. All optical fiber patch leads shall comprise of Single-mode 9/125μm fiber OS2. Jacket should be anti-rodent and outer metal spiral sheath protection, Sheath: LSZH. Make: R&M / Systimax / Siemon / Molex only.

14

4704

336

... More
OPTICAL FIBER: Supply, Installation, testing and Commissioning of Optical Fiber cable Armoured outdoor SINGLE MODE 6/12 CORE - OS2. Should be ISO.IEC 11801 - 2nd Edition, type OS2 and ITU-T REC G 652D. Tube Identification: Single tube/Multiple tube. Fibre protection (Tube): Polybutylene Terephthalate (PBT). Water Blocking: Thixotropic Gel (Tube) and Petroleum Jelly (Interstices). Core Wrapping: Polyethylene Terephthalate. Armouring: Corrugated Steel Tape Armour (ECCS Tape). Strength Member: Two Steel wires on periphery/Two FRP rods on periphery /Central Strength Member FRP. Sheath: UV Stabilized Polyethylene (HDPE). Maximum. Tensile Strength-Short Term: 1500N or better. Mass (Nominal): minimum 95 kg/km, Operating Temperature range should be -40°C ±70°C Make: R&M / Siemon / Systimax / Molex / Legrand only.

3100

254200

82

... More
JACK PANEL: Supply, Installation, testing and Commissioning of 8-port 19" 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19" 1U straight Patch Panel, 8-port,Should have integral cable management Metal shelf, Should accept Shielded as well as Unshielded jacks, Should have rear cable management shelf metallic powder coated. Make: R&M / Systimax / Siemon /Molex only.

32

267520

8360

... More
DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

1050

257250

245

... More
DSR item No.14.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal).

200

53000

265

... More
DSR Item No.1.53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.

-

-

-

... More
1 run of cable

700

42700

61

... More
DSR 1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.

-

-

-

... More
3 Module (100 mm x 75 mm)

32

11232

351

... More
Supply & fixing of RJ 45 SOCKET with Shutter for CAT 6 LAN cable (one module) including making connection as required completing the job to the entire satisfaction of EIC. The RJ 45 Socket should be of L&T (Oris)/ ABB (Ivie)/ Legrand (Arteor)/ Crabtree (Athena) only.

96

57600

600

... More
6U INDOOR RACK Supply, Installation, testing and Commissioning of 6U indoor rack with pole mount bracket and side fan for air perforation and water proof design. Rack should be certified IP-55 as per outdoor environment. Rack should contain 3 sockets PDU. Make: Rittal / Netrack / Valrack / Dlink only.

32

167264

5227

... More
9U INDOOR RACK Supply, Installation, testing and Commissioning of 9U indoor rack with extra depth & pole mount bracket and side fan for air perforation and water proof design. Rack should be certified IP-55 as per outdoor environment. Rack should contain 3 sockets PDU. Make: Rittal / Netrack / Valrack / Dlink only.

1

10000

10000

... More
PATCH CORDS CAT 6, 1MTR: Supply, Installation, Testing and Commissioning of CAT6 UTP LSZH 24 AWG Patch Cord - 1 Mtr with cross separator, Manufactured from stranded wires for longer flex-life, Minimum length of 1m, and maximum length of 5m conforming to the following standards like EN 50173, ISO/IEC 60603-7 & 11801/IEC 60332-1, EN 50173-1:2011 Class E,ETL Verified AS/CA S008:2020. Make: R&M / Siemon / Systimax / Molex / Legrand only.

256

98048

383

... More
24 PORT FIBER LIU: Supply, Installation, testing and Commissioning of 24 Port Fiber LIU which have sufficient slots to accommodate 24/12 Duplex LC/SC Ports ,Should have fiber management provision inside with splice tray and other accessories, Should be rack mountable 1U, Should have Splice holder for minimum 24 Fiber cores, Should be made of Cold Rolled Steel, Material Should steel: 1.5 mm, powder-coated The enclosure/LIU should have locks to secure all the fiber terminations & must have front cable management to properly route patch cords. No of fiber ports should be upgradable up 96 ports LC/SC Style. Make: R&M / Siemon / Systimax / Molex only.

1

11831

11831



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.