Chandigarh Administration Tender
View complete overview of Chandigarh Chandigarh Administration Tender
Chandigarh Administration Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Jul 2024
Closing Date12 Jul 2024
Tender Amount₹ 14,23,431
Costs
EMD
₹ 28,469Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CHD_81120_1Bid Award Id
ViewTender No
PH8/2024/1631811/82Tender Authority
Chandigarh Administration ViewPurchaser Address
-Website
http://http://chandigarh.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PITC and Handing Over of VRV/ VRF Air Conditioning system in VC Studios in the Model Jail Sector 51 UT Chandigarh
BOQ Items
... More
Supply, installation, testing & commissioning of Modular type outdoor units equipped with highly efficient multiple scroll/ DC twin rotary compressors fully inverter controlled (individual inverter for each compressor) i.e. changes its speed in accordance to the variation in cooling loads, special heat exchanger, low noise condenser fan, auto check function for connection error, auto address setting and capacity as mentioned below including all hardware & accessories & including full charging of R-410A refrigerant gas complete i/c powder coating complete as per specifications. The units should be with necessary weather protection coating. The coating should be done before bringing the units to site. Out door units shall be provided with MS stand of suitable size duly painted with corrosion resistant paint suitable for outdoor application.
-
-
-
... More
All the units shall be provided with built-in microprocessor control panel, for automatic operation and capacity control, Refrigerant Cooled PCB, Automatic Refrigerant charge function
-
-
-
... More
All compressor shall have inverter technology i.e. outdoor units shall have all inverter based compressor .
-
-
-
... More
All Bidders has to submit the test certificates along with the delivery of VRF/VRV Units at site. A draft Format of the same need to be submitted along with in the Technical Bid
-
-
-
... More
Variable refrigerant flow modular type air- conditioning system suitable for Cooling/Heating by inverter driven capacity control compressor Outdoor unit having minimum COP 3.5 at 100% and minimum 6.5 at 50% Load, at 35 deg C ambient temperature in cooling conditions (To crosscheck COP orginal data sheet to be provided from OEM )
-
-
-
... More
Insurance of Units ,Unloading at site, placement of Outdoor Units on the foundation,stands, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned VRF/VRV by OEM.
-
-
-
... More
Note: The civil foundations reqd shall be made by the Vendor/Contractor
-
-
-
... More
5.0 HP (Heating and Cooling mode of single phase machine)
-
-
-
... More
THE ENTIRE EQUIPMENT INCLUDING INSTALLATION & GAS CHARGING ETC. SHALL CARRY A WARRANTY OF 2 YEARS FROM THE DATE OF COMMISIONING AND HANDING OVER FOR COMPLETE RUNNING OF THE SYSTEM
-
-
-
... More
Make:As per make List
-
-
-
... More
VRV/VRF Indoor UnitsNSR
-
-
-
... More
Supply, installation, testing and commissioning of following minimum capacity of VRV/VRF Hi Wall Units equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor or as per OEM, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less/Corded remote control, etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature
-
-
-
... More
Note : All indoor units should be of same make as of outdoor units
-
-
-
... More
Hi Wall Units
-
-
-
... More
0.6 TR
28
613088
21896
... More
Refnet / T / Y- JointsNSR
-
-
-
... More
Supply Installation, Testing and commissioning of fittings Pair of Ref Net / T / Y-joints etc. as per specifications.
23
99107
4309
... More
PIPINGNSR
-
-
-
... More
Refrigerant Piping
-
-
-
... More
Supply and Installation of Interconnecting Refrigerant Piping of various sizes as required for the full functionality of the VRF system including refnet joints etc. complete in all respects duly insulated with closed cell nitrile rubber class 'O' of K-Flex,Armacell,A-Flex with UV barrier film as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the department/hvac consultant in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. all piping shall be run in cable trays in interior and for exterior there shall be a cable tray both at the bottom and the top. all support system required for the installation of cable trays in interior or exterior shall be in the scope of the HVAC contarctor and nothing extra shall be paid for it. All HVAC piping , drainage and Cabling etc shall run at a height of 6 inches below RCC slab or as per site requirment on continuous cable tray of appropriate sizes. all beams shall be core cut to allow for passage of pipes etc & filled back with expanded polyurethene foam or any cement or plaster. rates quoted are inclusive of core cutting and cable tray etc complete in
-
-
-
... More
all all respects including painting in desired colour. on exterior side the cable tray shall be mounted on top & bottom side for added protection. Refrigerant Copper Pipe Make : Totaline/Mandav/Rajco/Daikin brand/Hariom
-
-
-
... More
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation
40
14160
354
... More
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation
20
10760
538
... More
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation
40
29040
726
... More
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 13 mm thick insulation
30
27660
922
... More
19.0 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 13 mm thick insulation
15
16740
1116
... More
P/F Insulation min.2 layer coating of Glass cloth ( 7 mill ) with star bond or equivalent adhesive UV stablized on liquid and gas copper pipe line separately on each pipe for outside building/open to sky .dia upto 80 mm (Note : Rate is quated for both liquid and gas pipe)NSR
15
5955
397
... More
Providing of Split Type Invertor Air Conditioner variable speed 1.0 TR capacity with Rotary Compressor (R-410 R-32 Refrigerant) Nominal Cooling Capacity 3000 Kcal/hr tolerance +- 10% with 5 star rating and additional parameter as given suitable for operation on 230 Volts, 50 HZ single phase AC supply capable of performing the following operations: (i) Cooling, (ii) Dehumidifying (ii) Air Circulation, (iv) Filtering, including installation charges, and cost of copper pipe upto 3 mtr. i.e. piping for suction and discharge and upto 3.0 Mtr. power wiring between indoor and outdoor 100% copper to the entire satisfaction of E.I.C. complete with copper tubing indoor/ outdoor and condensor unit with copper connection to compressor.
Make: Blue Star, Voltas, Carrier, Hitachi & Toshiba, Mitshubishi, Daikain (Basic Rate taken on Gem Portal)NSR
1
41877
41877
... More
Providing & Fixing of Powder coated ready made heavy duty out door stand for Split out door as per site requirement to the entire satisfaction of Engineer- in Charge. NSR
1
668
668
... More
Providing and Fixing of PVC Rigid drain Pipe complete in all respects from indoor unit to Disposal Points as directed by the E.I.C. Size ¾” including specials Diplast Or Equalivent. NSR
40
4400
110
... More
Referigerent Piping for Split AcsNSR
-
-
-
... More
Providing and Fixing of 22 gauge soft copper piping of size 3/8" / 5/8" or as per original manufacturer technical specification for A/C size, for Liquid & Suction sides, between indoor & outdoor units with 6 mm thick nitrile rubber insulation & protective covering for exposed whether/chasing including cost of chasing brick wall/RCC wall & repairing to original condition. The rate per meter includes cost of 1 meter No's of both 3/8” & 5/8” with insulation. Make Rajco., Mandev, Totaline.
2
1750
875
... More
Electrical Work
-
-
-
... More
Power Cabling and EarthingNSR
-
-
-
... More
Supply, installation, testing & commisioning of Aluminum/Copper conductor cables PVC sheathed, armoured cables of 1.1 KV grade with termination glands and GI earthing, identification tags, clamps and saddles etc.
-
-
-
... More
4.0Cx4 Sqmm Copper Armoured
20
9840
492
... More
4Cx2.5 Sqmm (flexible Cu Conductor)
40
7320
183
... More
Make : Havell's,Eko,Finolex,Polycab
-
-
-
... More
Control Cabling
-
-
-
... More
Providing & fixing control cum transmission wiring of 2 core x 1.5 mm shielded copper in suitable conduits to be placed on cable tray between indoor and out door unit & indoor unit & its remote controller and all other control wiring required for the full functioning of the HAVC system complate in all all respects
50
6550
131
... More
Make : Havell's,Eko,Finolex,Polycab
-
-
-
... More
Make :ABB/ Siemens/Schneider
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements