Chandigarh Administration Tender
View complete overview of Chandigarh Chandigarh Administration Tender
Chandigarh Administration Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date6 Feb 2024
Closing Date14 Feb 2024
Tender Amount₹ 1,34,028
Costs
EMD
₹ 2,700Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CHD_79129_1Bid Award Id
ViewTender No
E3/47W/221Tender Authority
Chandigarh Administration ViewPurchaser Address
-Website
http://http://chandigarh.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
MAINTENANCE OF E.I. IN NON RESIDENTIAL BUILDING AT CHANDIGARH (REPAIR/ SERVICING OF HT VCB AND SERVICING OF 500 KVA TRANSFORMER IN 11 KV SUB STATION AT POST GRADUATE GOVT. COLLEGE (CO-ED), SECTOR-11, U.T. CHANDIGARH).
MAINTENANCE OF E.I. IN NON RESIDENTIAL BUILDING AT CHANDIGARH (REPAIR/ SERVICING OF HT VCB AND SERVICING OF 500 KVA TRANSFORMER IN 11 KV SUB STATION AT POST GRADUATE GOVT. COLLEGE (CO-ED), SECTOR-11, U.T. CHANDIGARH).
BOQ Items
... More
DSR 2.22 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2
628
314
... More
Supply and filling of transformer oil (Dehydrate oil) in the existing transformer. The job includes the cost of all petty material require to complete the job.
35
4200
120
... More
Dehydration of Transformer oil. The job includes the cost of labour and material required to complete the job.
915
10980
12
... More
Drain out of transformer oil, opening of transformer part and replacement of gasket, oil seal and silica gel, breather of 500 KVA transformer to stop of the leakage of oil as required at site, refilling of oil after complete the job to the entire satisfaction of Engineer-in-charge.
1
8000
8000
... More
Supply and Erection rubber mat of size 6’x3’x12 mm thick (ISI mark) wide of superior quality of approved make as approved by the Engineer-in-charge to be laid on floor in HT room in front of panels and transformers.
5
10000
2000
... More
Repairing & Servicing of various type of ACB’s of various ratio from 400 Amp. to 1600 Amp. of various types of make. The job includes dismantling of ACB’s from L.T. panel, re-installation of the same after servicing in the LT control panel unit. The cost also includes lubrication of movable parts, replacement of minor parts during the serving job being done at site. The job includes doing the repair of U/V coil, Shunt coil etc.
-
-
-
... More
Servicing of LT ACB’s 400 Amp. to 1600 Amp.
2
10000
5000
... More
Repairing & serving of 11 KV H.T. VCB of 800 Amp. to 1600 Amp. Of Crompton/Schneider/L & T/ Kirlosker make. The job includes the dismantling of job’s & reinstallation of the same in the control panel unit. The cost also includes cleaning the 11 KV contacts on H.T. VCB lubrication of movable parts of mechanisms of the panel units replacement of minor parts during the servicing job being done at site. The job includes servicing and the costs of minor parts & other petty material required to complete the job i.e. The job includes doing the repair of U/V coil, Shunt coil etc.
1
8000
8000
... More
Supply, erection, testing & commissioning of batteries of the following capacities in existing UPS after dismantling the old/ defective batteries from the Site. The job includes connection of all batteries and replaced burnt out wires as required at site with the cost of material & any other petty items as required at site to complete the job to the satisfaction of the EIC of the work. Make Exide/ Amron/ Luminous only.
-
-
-
... More
Sealed Mtc. free batteries 12 V 42 AH Capacity
2
8700
4350
... More
S/I/T/C of modular type ABC powder based fire extinguisher ceiling mount with required accessories as per site requirement. The job includes cost of other petty material and labour etc as required to complete the job to the entire satisfaction of Engineer-in-charge.
-
-
-
... More
10kg modular type ABC powder based fire extinguisher.
1
4956
4956
... More
Dismantling, refilling & re-erection of CO2 type of 9 kg capacity Fire Extinguishers ISI marked duly erected/ hung on wall with hooks including the cost of hooks with all material & labour required to complete. The job includes cost of other petty material and labour etc as required to complete the job to the entire satisfaction of Engineer-in-charge.
6
3600
600
... More
Supply and Erection of shocks treatment chart written in Hindi English and local language duly framed in wood frame with glass complete as required. The job includes cost of other petty material and labour etc as required to complete the job to the entire satisfaction of Engineer-in-charge.
1
100
100
... More
Supply and Erection medium size first aid box made of 16 gauge MS sheet of size 14’’x7’’x5’’ with 6 wound dressing 3 burns dressing 13 gms absorbent cotton wool one dressing scissor one bottle of sprit of sal volatile 1 tube of burn ointment.
1
1440
1440
... More
Supply and Erection of 4 nos. sand buckets of 10 ltr. Capacity each made out of 24 gauge G.I. pipe sheet the bucket with sand shall be reacted on suitable size of angle iron stand fabricated out 1 ½ x 1 ½ x 1/8’’ angle iron having hooks for hanging the buckets in two rows.
1
2090
2090
... More
Supply and Erection of Digital type meter suitable for three phase AC supply 50 Hz for the reading of each phase. The capacity making should be suitable for 0-300 amp for amp meter and 0-500 Volts for voltmeter. The meter is of schenider make. The job includes cost of copper wire of suitable size as required for interconnection, selector switch and indicating Lamps to complete the job to the entire satisfaction of engineer in charge.
-
-
-
... More
Volt Meter
2
5000
2500
... More
Amp Meter
2
5000
2500
... More
Supply and Erection of indicators 110 to 220 Volt indicator should be ABB/L&T/OZO make only.
6
1200
200
... More
Supply and carriage of aluminium ladder 20 feet Light Duty Self Supporting Stool with Platform of the finest quality and durability. The job includes cost of Labour and other petty material charges required to complete the job to the entire satisfaction of Engineer-in-charge of work.
1
15000
15000