Chandigarh Administration Tender

View complete overview of Chandigarh Chandigarh Administration Tender

Chandigarh Administration Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date16 Jan 2024
Closing Date29 Jan 2024
Tender Amount₹ 75,43,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

2

16048

8024.18

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

10

3082

308.21

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

10

2620

262.03

... More
Foundation for DG Set

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth 1.5m in width as well as 10sqmm (on plan) including disposal of excavated earth, lead up to 50m and lift upto 1.5m disposal earth to be leveled and neatly dressed.

-

-

-

... More
All kind of soil.

6.64

1178

177.5

... More
Supplying and filling in plinth with jamuna sand under floors including, watering, ramming consolidating and dressing complete.

3.89

8261

2123.75

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level.

-

-

-

... More
1:5:10 (1 cement: 5 coarse sand (Zone-III): 10 graded stone aggregate 40 mm nominal size).

2.21

14406

6518.6

... More
Steel Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.

-

-

-

... More
Thermo-mechanically treated bars

1070.85

115491

107.85

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :

-

-

-

... More
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)

9.73

83516

8583.4

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:

-

-

-

... More
Cement mortar 1:4 (1 cement :4 coarse sand)

4.01

29556

7370.75

... More
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.

25.55

9785

383

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :

-

-

-

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

11.08

9334

842.5

... More
Supply and laying of XLPE insulated PVC sheathed Aluminum conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be in existing trench/pipe. The job include the cost of making connections with suitable size of Al. Lugs/ thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. Make should be of Polycab/ KEI/ RPG/ Havells/ Finolex/ R.R. Kabel only.

-

-

-

... More
Size 300 Sq.mm 3.5 Core PVC Al. Arm. Cond. Cable

110

223850

2035

... More
Supply, Erection, Commissioning and Testing of 3 Phase 415V, 400 KVA Silent Diesel, Gen Set of 1500 RPM, PF 0.8 Lagging directly coupled to alternator mounted on a common base frame by making required foundation (The DG Set should comply with CPCB-IV). The Engine should be of Turbo charged air cooled/ water cooled with radiator. The set should be complete with control panel fuel tank air cleaner blower fan fuel pump variable speed with Electronic governor fuel filter lube oil filter and pump, battery charger, 24 V D.C. battery alongwith battery leads of compatible capacity & instrument panel comprising of switches with key, lube oil pressure gauge, water temperature gauge, battery charger, volt meter, safety control for low lube oil pressure over speed and high cooling water temperature with tripping etc. The gen set shall be provided with acoustic canopy as per technical specification. The set must be supplied completely assembled. The job includes making necessary connection of existing cable with lugs / thimble upto control panel. The DG set should be OEM/ OEA manufactured only.

-

-

-

... More
The work is to be completed to the entire satisfaction of the Engineer-In-Charge of the work. A. Engine: 6 Cylinder minimum 303 BHP 4 stroke 1500 RPM Water cooled engine of Cummins/ KOEL/ Volvo Penta/ Greaves Crompton make, capacity taking 10% over load for one hour in any ten hours running & complete with fly wheel starter motor with following parts as under: a) Radiator cooling systems b) Fly wheel to suite flexible / rigid coupling c) Fly wheel housing complete with starter gearing and coupling d) Fuel hoses e) Electronic/ Mechanical Governor with Mechanical fuel injector f) Air cleaner with vacuum indicator g) Fuel and lubricant oil filter. h) By pass filter i) Fuel pump j) Gear Driven water pump k) Lubricant Oil pump l) Electric starter 12 V DC m) Battery charging alternator with build in regulator n) Residential silencer o) Vibration damper p) Engine mounted anti vibration pads q) Flexible bellow for silencer

-

-

-

... More
B Alternator: The alternator shall be KOEL Green / Stamford / Leroy Somer/ Crompton Greaves G1R 315 SA, self-excited, self-regulated brushless and continuously rated for 400 KVA at 0.8 PF (lag) with IP23 protection. 50 Hz, 3 Phase 415 V 50 Cycle 4 wire system and shall be provided with static excitation unit alternator insulation shall be class H suitable to with stand tropical conditions and shall generally comply with BS: 2613/5514 and IS 4722 including day fuel tank as required for 400 KVA Diesel Generating set. C The generator should have following features / safeties on engine controller/ AMF panel. a) Over current (Shutdown) b) Short Circuit c) Over Voltage d) Under Voltage e) Under Frequency g) Reverse Power KW & KVAR h) Loss of Excitation i) Single Phase Fault Protection j) Alt. Thermal Damage Protection

-

-

-

... More
D Other Feature / Protections on Engine Side a) Low loop oil pressure Warning and shut down b) HWT Warning c) Low Coolant Temperature d) Low coolant level e) Fail to crank shut down f) Over crank shut down g) Over speed shut down h) Magnetic pickup failure shutdown i) Emergency stop shut down E Base frame Suitable base frame of Sturdy deign made of MS / banded channel as per OEM design with necessary re-enforcement take the load of engine and alternator pre-drilled holes for permanent installation on pre-cast foundation with AVM pad including cost of the same. F Fuel Tank Daily service fuel tanks of size 14 gauge having in built capacity as per OEM design with drain air vent inlet and out let connection along with arrangement for fixing the same.

-

-

-

... More
G Battery 2 Nos. battery of 12 V suitable size (Maintenance free Dry type battery) of Exide/ Amron/ Cummins Gen Power/ Koel Green with battery lead for electrical starting. H Canopy The Acoustic canopy sound proof enclosure for installation of 400 KVA DG set with following specification. (a) Outer Enclosure. The outer enclosure is fabricated from CRCA 16 GMS Sheet powder coated paint. These sheets are first cleaned with a special chemical by giving anti rust anti grease and phosphate treatment. (b) Insulation For sound alteration a high quality insulation material is used on all five sides and the material is supported by MS/ Al. perforated sheets. (c) Forced/ Natural ventilation The enclosure shall have natural ventilation/ forced ventilation system to maintain temperature as per manufacturer design.

-

-

-

... More
(d) Silencer The enclosure is fitted with a special residential silencer to minimize back pressure on the engine and to give max sound suppression of the exhaust gases. (e) The enclosure is corrosion resistance weather proof and suitable for outdoor installation. The enclosure can be placed on the RCC foundation without bolting the platform should have enough space to house panel, battery, fuel tank inside canopy. Heavy duty sturdy steel base frame for placement of D.G. Set with AVM Pads. The provision for air exhaust silencer for preventive leakage of sound. Maximum number of open-able door for access to virtually every part of DG set for complete maintenance foam of 45mm thickness/ Rock wool 100mm thick (min.) and 96 Kg cubic meter shall be used as acoustic material. The canopy should be manufactured by engine manufacturer/ OEM duly approved by ARAI (Automotive Research Association of India) CPCB for 75 dB(A) @1 Mtr. at 75% load under free field condition. The maximum permissible temperature rise above ambient shall be 5 degree Celsius to 7 degree Celsius inside canopy.

-

-

-

... More
I Supply, Erection, Testing and Commissioning of AMF panel suitable for 400 KVA Gen Set. The AMF panel is so designed that the Gen set starts automatically on complete failure of mains supply or fall of voltage and / or frequency below a preset value and takes over load. On restoration of mains supply the load is automatically transferred back. On a three phase main supply. The set starts automatically on failure of one or more phases. The AMF panel should be cubical type construction and fabricated from 14 GMS sheet outdoor IP-54 double door. The panel should be cleaned degreased and phosphate before Priming/ painting the body with 2 coats of enamel paints. The panel should be suitable for free standing floor mounting for outdoor installation. The panel should be provided rubber gaskets between all joints and opening to make it dust and vermin proof.

-

-

-

... More
The internal wiring of the control panel/ AMF panel should be completed with the followings. - AC voltmeter mounting type rating 0-500 V make AE/ UE/ Schneider. - Voltmeter selector switch - Frequency meter, KWH meter make AE/UE/ Schneider - KW meter, - PF meter, - Ammeter of suitable rating flush mounting Conzerv (Schneider)/ Rishab make with C.Ts of suitable rating - MCCB suitable rating - Variable overload short circuit earth fault protection relays of L&T/GE make - main supply voltage monitor set up - DC control relays of timers - Set of push buttons, start, stop ACRNOL edge, Re-set mains, breakers close trip, Alternator/ Breaker/ Close/ Trip - Set of indicator lamps of the following load, set on mains load on set, set fails to start, low oil pressure - High water temp meter (trip) auto-alarm hooter.

-

-

-

... More
The AMF panel should be complete with MCCB, battery charger, wiring etc. AMF should also be provided with facility to bypass A.M.F. if required at any stage. The AMF panel must be of same make of D.G. Set/ OEM manufacturer only. J Testing The complete Gen set shall be tested as per relevant IS provisions. Following test shall be carried out. i) Continuous running of Gen. set at full load for 8 hours for which cost of lubricating oil and HSD shall be borne by the firm. ii) Routine testing as per IS provision iii) Measurement of fuel oil consumption and lubricating oil consumption at 75% of full load. iv) Alternator efficiency at 75% & 100% load. v) The measurement of noise level at 75% load.

1

6758129

6758129

... More
Providing and fixing Exhaust pipe for Extension of Silencer for making the stack height 10' above height of the building of smoke exhaust for 200/250 KVA DG Set as required at site as per norms of local Pollution Department

-

-

-

... More
Supply & Fixing of 200mm Dia of MS iron pipe C Class of ISI marked, length of the pipe should be to make the stack height of the exhaust as per CPCB norms, including transportation at site cutting, welding, grinding

8

10768

1346

... More
Supply & Fixing of 150mm Dia of MS iron pipe C Class of ISI marked, length of the pipe should be to make the stack height of the exhaust as per CPCB norms, including transportation at site cutting, welding, grinding

8

10016

1252

... More
Supply & filling the glass wool/ mineral wool 50 mm thick along with wire mesh for coverage the exhaust pipe as required including transportation at site

16

15648

978

... More
Providing & fixing of wire mesh over the glass wool/mineral wool 50 mm thick for holding the glass wool on pipe for coverage of the exhaust pipe as required at site including transportation at site

16

2352

147

... More
Cladding of existing pipe and wool bonded with wire mesh with fabrication, supply and fixing of Aluminum sheet of suitable size around the MS pipe on already filled mineral wool/glass wool around exhaust pipe of Gen Set as required at site including transportation at site

16

4672

292

... More
Making Testing/ Inspection chambers in each exhaust pipe for sampling and testing the smoke of DG set as required at site, including transportation at site

1

1716

1716

... More
Fabrication, Supply, Erection of bends as per site requirement, including transportation at site.

2

5148

2574

... More
Fabrication, Supply, Erection of flange as per site requirement for coupling the silencer with exhaust pipe including transportation at site.

2

6862

3431

... More
Providing and fixing following rating MCCB 4 pole 415 Volt (Thermal magnetic/ microprocessor release) without MS enclosure for Over load and short circuit protection, 50 KA Breaking capacity (Ics=100% Icu) with positive isolation. The overload & short circuit release shall be of adjustable type, suitable for isolation The MCCB is to be installed in existing cubicle panel / angle iron board/ VTPN BDB / MCCB enclosure including drilling holes in cubicle panel / angle iron board, making connections with suitable rating of copper wire / copper strip etc. as required. The job includes the cost of spreaders terminal links etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The MCCB should be of L&T/ Siemens/ Schneider/ Legrand/ ABB make only.

-

-

-

... More
630 Amp 4 Pole MCCB (Micro Processor release). (01 no. for fixing and 01 no. standby)

2

105570

52785

... More
Supply and erection of on load Change over switch with Enclosure of following ratings installed in existing switchboard with nuts & bolts of requisite size after making boles etc. The job includes making all necessary connection with New Change Over switch testing, commissioning & labour required to complete the job. The job includes the cost of to making inter connection of requisite size capable of carrying full load current with copper wire / solid connections with copper strips to the entire satisfaction of Engineer in Charge.

-

-

-

... More
Change Over Switch 630 Amp 415 Volt 4 Pole

1

33381

33381



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.