Chandigarh Administration Tender
View complete overview of Chandigarh Chandigarh Administration Tender
Chandigarh Administration Tender
Electrical and Electronics
Eprocure
Opening Date17 Feb 2025
Closing Date10 Mar 2025
Tender Amount₹ 35,63,516
Costs
EMD
₹ 71,270Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_CHD_84715_1Bid Award Id
ViewTender No
E2/24/175Tender Authority
Chandigarh Administration ViewPurchaser Address
-Website
http://http://chandigarh.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
DSR 2.27 (Civil) Supplying and filling in plinth with jamuna sand under floors including, watering, ramming consolidating and dressing complete.
1.38
2066
2851.08
... More
DSR item No. 4.1.11 (Civil) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level.
1:5:10 (1 cement: 5 fine sand derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources).
2.77
6023
16683.71
... More
DSR 5.22(Civil) Steel Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.
Thermo-mechanically treated bars of grade Fe-500D or more.
202
105
21210
... More
DSR 5.1 (Civil) Providing and laying in position specified grade of reinforced cement concret, excluding the cost of centering, shuttering, finishing and reinforcement- All work upto plinth level:
1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural source: 4 graded stone aggregate 20 mm nominal size derived from natural sources) .
1.84
8352
15367.68
... More
DSR 13.1.1 (Civil) 12 mm cement plaster of mix: 13.1.1 1:4 (1 cement: 4 fine sand)
11.84
338
4001.92
... More
DSR Item No. 5.9.1 (Civil) Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, basis of columns, etc. for mass concrete.
8.45
382
3227.9
... More
DSR 10.25.2 (Civil) Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
250
168
42000
... More
DSR 12.1.1 (Civil) Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
-
-
-
... More
1.00 mm thick with zinc coating not less than 275 gm/m²
15
1418
21270
... More
DSR Item No.1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
150
788
118200
... More
DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator).
-
-
-
... More
4 way (4 + 12) Double door
27
4275
115425
... More
DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
Single pole
420
268
112560
... More
Triple pole
27
1052
28404
... More
Triple pole and neutral
27
1283
34641
... More
DSR item No.5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
4
7808
31232
... More
DSR item No.5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
14461
28922
... More
DSR item No.5.8 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
20
1016
20320
... More
DSR item No.5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
40
150
6000
... More
DSR Item No. 9.1Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
... More
3½ X 185 sq. mm (57mm)
6
914
5484
... More
4 X 16sq. mm (28mm)
16
323
5168
... More
DSR 14.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
-
-
-
... More
63 mm dia (OD-63 mm & ID-51 mm nominal)
780
258
201240
... More
120 mm dia (OD-120 mm & ID-103 mm nominal)
220
385
84700
... More
Supply and laying of XLPE/PVC insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing RCC/HUME/METAL/DWC pipe as required at site. The job includes labour charges of laying the cable and making connections etc. The cable should be of Polycab/ Havells / RR Kabel/ KEI/ Grandlay/Finolex make only.
-
-
-
... More
Size 16 Sq. mm 4 core
880
278
244640
... More
Size 185 Sq. mm. 3.5 Core
250
1484
371000
... More
Providing and fixing following rating MCCB 4 pole 415 Volt (Thermal magnetic / microprocessor release) for Over load and short circuit protection, 36 KA Breaking capacity (Ics=100% Icu) with positive isolation. The overload & short circuit release shall be of adjustable type, suitable for isolation The MCCB is to be installed in existing cubicle panel / angle iron board/ VTPN BDB / MCCB enclosure including drilling holes in cubicle panel / angle iron board, making connections with suitable rating of copper wire / copper strip etc. as required. The job includes the cost of spreaders terminal links. The job also includes cost of MS enclosure or direct/ extended rotary handle etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The MCCB should be of Lauritz Knudsen/ Siemens/ Schneider/ Legrand/ ABB/Hager make only.
-
-
-
... More
100 Amp 4 Pole MCCB (Thermal Magnetic release).
5
10930
54650
... More
250 Amp 4 Pole MCCB (Thermal Magnetic release).
1
24750
24750
... More
S/E of following way 100 amp. rated vertical type three pole and neutral sheet steel, IP43, MCB distribution board 415 volt in recess complete with 4 pole 100 amp. MCCB breaking capacity 25 KA (min), MCB SP tinned copper bus bar, neutral bus bar, din bar inter connections, power pointed including earthing etc as required. The vertical TPN distribution board should be of Hager (Novello+) / Legrand (Ekinox3) / Schnieder (Acti 9) / Siemens (Betagard) / ABB (Elegance) / Lauritz Knudsen (Exora) make only. The 4 pole 100 amp. 415-volt MCCB should be of Hager /ABB / Lauritz Knudsen / Schneider / Legrand / Siemens make only. The MCCB should have adjustable thermal and fixed magnetic release for over load and short circuit protections.
-
-
-
... More
8 way (4+24) Double door complete with 1 No. 100 Amp. MCCB as incomer and having space for 24 nos. MCB single pole, 100 Amp insulated Copper busbar arrangement for each phase.
8
17525
140200
... More
Fabrication, Supplying, Installation, Testing and Commissioning of Indoor type cubicle type fully enclosed compartmentalized Electric Panel of suitable size (300mm-900mm) deep as required at site suitable for three phase 50 Hz 415 volt AC supply system made out of 1.6 mm thick CRCA sheet duly strong thread with suitable size of MS channel members and base weather proof dust and vermin proof, ventilated with louvers at sides removable gland plates at the bottom, earthing studs at both ends duly painted with powder coated finish of approved shade and two coats of anticorrosion paint including providing and fixing of four strip main and auxiliary aluminium bus bars of rating (100 Amp. to 300 amp.) as required at site, multifunction meter, LT phase indicator lamp for each incomer/ outgoing, MCB distribution board metering unit and having space for accommodating various MCCB’s, MCB SP/ DP/TPN and energy meter etc as per site requirement. The manufacturer/ fabricator of LT panel should posse’s type test certificate/ reports w.r.t. construction/ manufacturing of LT panel confirming to IEC 61439 Part 1 &2 with breaking capacity 50KA (minimum) & Degree of protection IP42 (minimum) from CPRI /ERDA approved Lab.
1.25
30400
38000
... More
Supply & erection MCB 3 Pole 63 Amp 415 Volt 10KA Breaking Capacity ‘C’ curve without enclosure. The job includes the labour charges and other petty material required to complete the job. The MCB should be of Lauritz Knudsen (Exora)/ Legrand (DX3)/ Schneider (Acti-9)/ ABB (SB200M)/ Siemens (Betagard) make only.
4
1600
6400
... More
Making of Haudi of following size for drawing of underground cable etc. constructed with bricks wall 4½” thick and plastered from the inner side with cement, sand, mixture 1:5. The RCC cover moulded in an angle frame of size 35mm x 35mm x 5mm should be provided above the Haudi which should rest on 40mm x 40mm x 5mm angle iron frame fixed on the upper portion of the Haudi. The cover should be provided with lifting arrangement. The rate includes all labour and material to complete the job with 1:4 CC mixture.
-
-
-
... More
Size 2’x2’x2’ deep
11
3850
42350
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements