Chandigarh Administration Tender

View complete overview of Chandigarh Chandigarh Administration Tender

Chandigarh Administration Tender

Works
Civil And Construction
Electronics Equipment
Civil Works Others
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Oct 2024
Closing Date18 Nov 2024
Tender Amount₹ 42,14,62,779 
Notes
Download

Costs

Summary

Up-gradation Of Civil, Electrical And Public Health Work For Multipurpose Hall At Post Graduate Govt. College, Sector 46, Post Graduate Govt. College, Sector

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender Notice and Conditons
Components (Civil, P.H., Electrical)
UP-GRADATION OF CIVIL, ELECTRICAL AND PUBLIC HEALTH WORK FOR MULTIPURPOSE HALL AT POST GRADUATE GOVT. COLLEGE, SECTOR 46, POST GRADUATE GOVT. COLLEGE, SECTOR 11 AND POST GRADUATE GOVT. COLLEGE FOR GIRLS, SECTOR 11 AND GOVT. COLLEGE FOR HOME SCIENCE,
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All Kinds of Soil (DSR 2.6.1)

135.68

172

23433.29

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia (DSR 2.10.1.2)

360

342

123350.4

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (DSR 2.25A)

75.91

681

51739.5

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.8)

53.33

6628

353475.51

... More
CEMENT PLASTER

-

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand) (DSR 13.2.1)

940.03

388

365352.06

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent (DSR 11.56.1)

2138.22

4360

9323280.67

... More
Extra For Cutting Polished Granite stone strips of 50mm and fixng on the ramps to make ramp anti skid by palcing them angualrly as per direction/ satisfaction of EIC. (NS)

182.55

304

55595.6

... More
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622, of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. (DSR 16.90)

90.9

1963

178447.61

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm (DSR 8.2.2.2)

18.63

4997

93105.66

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR 8.5)

40

952

38091.2

... More
Providing and fixing machine cut, Italian Marble shade slab / tile (Statuario) of size 2398 x 1198mm for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by theEngineer-in-Charge. (NS)

837.36

5613

4700302.65

... More
Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge: (DSR 15.53)

44.64

3786

169011.06

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately): Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.2.3)

929.88

626

582179.27

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) (DSR 21.3.2)

34.36

1464

50324

... More
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). (DSR 9.12)

34.36

171

5897.55

... More
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. (DSR 21.1)

36.97

4862

179776.24

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR 10.28)

1043.52

751

784257.46

... More
Providing and fixing Aluminium frame work (at all heights of wall) 600mm c/c bothways for wall panelling as per design drawing consisting of aluminium tubular sections of size 50x38mm having thickness not less than 2mm. The framework to be filled with 50mm 1200GSM non-woven thermal bonded polyester wadding ( Make Nowofill / Himalaya / Gyptech) held in position with 18 mm GI chicken mesh of 24SWG with SDS screws and oversize washers.The frame to be fixed to the walls by means of angle holdfasts of suitable length out of 35x35x4mm MS angle duly given redoxide and paint complete with expandable anchor fasteners of 65x10mm dia fixed o @1200mm C/C bothways.The frame work shall be executed as per drawings ,specifications & instructions of engineer in charge. (NS)

2979.78

3841

11446526.89

... More
Providing and laying of 50mm thick 1000GSM Non woven thremal bonded polyester wadding to be laid in cavity behind wall panelling including fixing 24Guage chicken mesh jali complete in all respect and to the entire satisfaction of the Engineer-in- charge. ( Note: The Contractor to submit Manufacturing Test Certificate) (NS)

2115.63

1283

2715178.39

... More
Providing & fixing false ceiling at all heights with 25mm thick 450kg / cum density wood fibre board factory painted dark grey laid over the existing suspension grid.. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. (NS)

242.16

2647

641125.86

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recomme-nded jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:

-

-

-

... More
12.5 mm thick tapered edge Gypsum Board mositure resistant board (DSR 12.45.3)

1579.6

1487

2350144.68

... More
Providing and fixing glass wool ceiling tiles (NRC =0.9) at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. (NS)

240.24

3124

750581.83

... More
Providing and fixing 2nd class teak wood plain lining tongued and grooved skirting, including wooden plugs complete with necessary screws and priming coat on unexposed surface.25 mm thick. The work shall be executed as per drawings ,specifications & instructions of engineer in charge. (NS)

91.51

5504

503694.83

... More
Providing and fixing 12mm premium grade fire retardent ply for wall lining with necessary screw, priming coat on un-exposed surface complete as per drawing and direction of Engineer-in-Charge. Recomended Make : Duro , Century , Merino, Green . The ply to be fixed to the existing GI frameowrks ( Frameworks to be paid separately in item no6) at all heights. 12mm thick ply . The work shall be executed as per drawings ,specifications & instructions of engineer in charge. Including coat of Fire retrdaer coating at rear side of the plyThe work shall be executed as per drawings ,specifications & instructions of engineer in charge. (NS)

2664.07

2074

5526453.37

... More
Extra for 18-21% perforations of size 8mm & 12mm or 12mm x 50mm slits made through CNC / drill machine as per design drawings and direction/ satisfaction of EIC. (NS)

983.26

313

308065.19

... More
Providing & Fixing decorative Wood Veneer at all heights of walls, 4mm glued over the exisitng ply fixed over the framework and complete as per engineer in charge. (NS)

1500.34

3696

5545901.79

... More
Providing & fixing of the Acoustical panels (at all height) of 9mm thickness with square or beveled edge manufactured from 100% Polyethylene Terephthalate (PET) having density of 100 ( the panel shall have 60% recycled content) , Kgs/m3, Manufactured panels should be fire resistant as per B1 Class A (make Himalaya/ Nowofill/ Gyptech). The panel is to be glued over existing framework and perforated ply (Ply & GI framework paid separetely in item no. 21 & 27). The work to be done complete as per the design & instructions of engineer in charge including accessories as required. (NS)

1000.07

5080

5080385.6

... More
Providing & fixing of stretch Fabric Acoustic Panelling at all height with Inherently Fire retardant fabric The fabric is to be stretched using UPVC grippers provided @ 1200mmc/c or wherever required as per the design drawing complete with top , bottom & End. The Gripper to be fixed over 12mm FR ply. The Fabric to be gapped with Fire Retrdant Melamin Foam ( Supreme) .The foam to be glued over the perforated 12mm FR ply fixed over GI framework (Ply & GI framework paid separately in item 21 & 27) T Including finsihing the edges as required. The work to be done complete as per the design & instructions of engineer in charge including accessories as required. (NS)

464.03

5636

2615546.86

... More
Providing and fixing in position wall acoustic panelling made from Rubber Wood Slats of various width and 12 mm thick over already existing GI/Al frame on wall including cost of required cut-outs as per architectural-acoustical design and drawing etc. complete in all aspects and as per directions of Engineer-in-charge/architect. (Make:Euro,Satyam). The panels to be fixed on the I framework with impalers / as per manufacturers recommendations (The framework to be payable in item no 21). The work to be done complete a per specifications & instructions of engineer in charge. (NS)

314.06

4549

1428894.49

... More
Providing & fixing of at all heights 12mm thick 16-21% open area jali as per the pattern in deisgn drawings . The Jali is to be out of Corian ( Solid acrylic surface of Hanex/ Dupont) ( Colour N White)with edge jointing wherever required in the design as desired by the Architect. The jali is to be backed with IFR Crape fabric (Nexgen / RSWM ) fixed as per drawing over a Aluminium gyp steel framework ( framework to be paid for seperetly item no.21). Including the cost of SS spacers of SS of required size. The work shall be executed as per drawings ,specifications & instructions of engineer in charge. (NS)

88.42

16240

1435970.86

... More
Providing and fixing first class steam beech wood lipping/moulded beading or taj beading of size 70x50mm fixed with wooden adhesive of approved quality and screws/nail on external edges of stage .The work shall be executed as per drawings ,specifications & instructions of engineer in charge. (NS)

68.27

609

41583.26

... More
Providing and fixing 600x450x1100 mm podium top made out of 19mm block board complete with 1mm laminate on top & bottom. The table to have moldings & margin of teak at edges as per design drawings which are to be duly polished in required shade. The inner side of furniture to be given melamine polish in black colour after making base complete. i/c of all hardware fittings and accessories as required by the Engineer-in-charge. (NS)

8

20865

166927.92

... More
Providing and fixing glass panel front for the podium in 12mm thick glass with etching of the logo of the institution. i/c LED lighting Aluminium profile 8mm stip Complete with connector and transformer as per direction satisfaction of EIC. (NS)

8

10433

83467.84

... More
providing and fixing wooden cabinet of 2'0'' deep and 3'0'' height with openable shutter consisting of 18mm thick both side prelaminated particle board with one side decorative flat pressed 3 layer abd grade medium density ) grade I, type II conforming to IS 12823 ( exterior grade) lipped with hard wood lipping of size 18mm on exposed edges include cost of piano hinges and handle magnetic catcher, nail, screws, synthetic adhesives etc. and fixed in position with help of wooden gutties at wall complete in all respect to the entire satifaction of Engineer in charge. (NS)

25.83

8630

222926.07

... More
Providing and fixing of the sound acoustic baffle (at all height) consisting of high density 1.8 mm thick layer of polymer based visco elastic synthetic acoustic membrane asphalt free having a density of 2000 kg /cum infused in 20mm thick 450 kg /cumtr density wood wool board with cement platered surfaces. The joints to be fianlly sealed with manufacturer approved putty. Complete as per drawings and instructions of engineer in charge. (NS)

3543.7

5923

20991532.19

... More
Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) (DSR 13.116)

2194.99

2967

6513632.82

... More
Providing and fixing of the ceiling hung toilet cubicles for consisting of HPL 12mm panels to be suitably hung from the ceiling with all accessories like rails etc complete with door knobs etc. Make Merino ( Titan Series) or equivalent of Greenlam. Complete as per direction of EIC. (NS)

25

71516

1787911.75

... More
Providing and fixing Vertical lineal baffle ceiling (at all height) 100x50mm in wood grain finish made out of GI metal. The baffle balde shall be in size of 100x50x2440mm . The baffle balde shall be suspended using slotted U profile at on-centre spacing in multiples of 150mm longer lenth to be connected with joiners and the baffle to be closed with end caps wherever required. The U profile to be suspended from the ceiling @ 1200mmc/c with 6mm threaded rod and anchor fastner . U profile splice to be used to join more than one U profiles. Complete as required as per the drawings and instructions of engineer in charge. (NS)

1763.74

9180

16191591.77

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters :35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. (DSR 9.21.1)

120.57

2328

280692.99

... More
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :50 x 20 mm (DSR 9.40.1.2)

217.14

264

57413.99

... More
Supply & fixing of 83mm thick, having STC 40 Characteristics acoustic cum fire check door shutters, having Fire rating 120 Minutes minimum, including door frame of section 145mm x 75mm marrrantti wood fixed to the door jambs with anchor fastners as required, having infill of 47mm thick resin bonded glasswool of 24kg/cum density coated with FR Acrylic Sealant Sandwitched between two 9 mm thick calcium silicate boards (Starpan or equivalent) 100% without asbestos, Brucite and Meerschaum having a density not more than 1150kg/cum and thermal conductivity 0.14 W/M*K faced with 8mm thick commericial ply (green/merino/century) with heat activated intumescent fire seal strip of size 10mm x 4mm mounted in the grooves having hardwood lipping of size 15mm x 70mm and fire retradant 1mm thick laminate (merino/century/greenlam) facing on both sides in desired shade and colour. The door to be complete with all acoustic seals RP 24,16 & 38 (Lorient/ Astroflame U.K./Raven/Marshall) . The work shall be executed as per drawings ,specifications & instructions of engineer in charge. ( Note:Contractor to submit shop drawing & Test certificates from manufacturer ( The Manufacturers should already have a test report with complete Seals tested from CBRI Roorkee for the total design including door closers and panic bar) for approval of the Engineer incharge) . Recomended Make : Shakti Horman / Navair or equivalentas approved by engineer in charge. (NS)

147.34

33385

4919031.36

... More
Supply & fixing of 304 grade stainless steel ball bearing hinges from Marshall/Assa Abloy/IngersollRand of size 100x100x3mm thick complete .The work shall be executed as per drawings ,specifications & instructions of engineer in charge. (NS)

274

830

227677.56

... More
HEAVY DUTY DOOR CLOSER : Providing & fixing of Dorma's TS 93 , Brition's LCN1460 and Marshall MH-DC-S-14016 (3-4) exturded aluminimum body heavy duty 2 hrs fire rated door closer tested from CBRI Roorkee as per IS : 3614 Part -II and BS : 476 Part 20& 22 from CBRI Roorkee alongwith wooden /glazed / metal fire doors. The door closer shall be of type 3-4 , non handed having back check function , ANSI/BHIMA certified , and comples with EN 1154 for 100000 cycles.The door closer shall have a 10 year mechanical guarranty / warranty from the manufacturer and the same shall be submitted to the Engineer -in-charge . (NS)

77

36168

2784963.72

... More
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete. For Double door. Make Enox / Hafele/ Dorma / Briton:Double Leaf ( for all exits ) . Complete as per direction of EIC. (NS)

59

22953

1354231.13

... More
OUTSIDE ACCESS DEVICE (TRIM): Providing & fixing 304 grade external trim ( Latch & Lock) with 3 keys for providing outside access for panic bar of approved make Marshall MH-PB- SS- 11002 SS / Dorma 's PHX 03 / Von Duprin's CX 98 series for wooden /glazed / metal fire doors. all complete as per manufacturer's specifications, approved drawing and direction of the Engineer- in- charge. ( for all exits ) (NS)

58

6676

387250.34

... More
Providing and fixing 25mm dia & 400 mm long brushed steel finish pull handles with with long bolt and cap for fxing from outside only as per design approved by engineer in charge of Make Dorset , Dorma , Golden, Hettich ,Haffelle. (NS)

103

6609

680787.77

... More
Providing & Fixing of Flocked floor covering rolls or equivalent having a density of 70 million fibres of nylon 6.6 per M2, Appearence Retention Hexapod ISO 140-8, Friction Slip Resistance Test EN 14041 Class DS, sanitized anti-microbial treatment with resilient waterproof backing ,anti allergic cetrtified by British allergy foundation, anti static, thickness 4.3 mm and approximate weight of 1.8 k.g./sqm of roll form. The reaction to fire should be as per EN 13501-1: Bfl-s1. shade as approved by client and installed by approved applicator of manufacturer. Flocked flooring should be installed over cement based compound available within India. (NS)

1812.48

5895

10685312.72

... More
Providing and fixing in Position Solid Hardwood flooring with plank thickness of not less than 22 mm, width not less than 120mm and length not less than 1830 mm(Except at wall end) from reputed manufacturer. The flooring shall be fixed with tongue and groove interlocking system with clip method/(Synthetic adhesive).Two planks are joined with help of stainless steel clip/(Synthetic adhesive) to ensure control of expansion during climatic changes. Installation is done over 4 mm thick expanded polyethylene foam sheets to give cushioning effect, over prepared surface with necessary skirting of same material as of flooring . The Aluminum Anodised matching Color Transition profiles and Nosing's to be fixed where ever required. The planks are factory polished in laquer. A uniform gap of 12 mm is to be maintained all around the wooden flooring to allow for expansion due to climatic changeThe Flooring should have Environmental Friendly certification of Forest Steward council (FSC). The moisture content shall not exceeding B 0,6 and Fire classification shall be Cfl-S1 Category (DIN EN 13501-1), all complete as per direction of the Engineer in charge. (JUNKERS, DENMARK / BARBOSA PORTUGAL / CASTRO, EUROPE) (NS)

584.18

14995

8760293.18

... More
Providing & fixing of 2 No. staggered layers 12mm thick marine ply of approved make like century, Duro, Green Merino, fixed to Sal wood frame work of size 600 mm c/c both ways (Frame work to be Paid separately). The sal wood framework to be supported on 150x150x5mm held inposition with cleats and anchor fastners @ 900x600mm c/c Complete as per direction of EIC. (NS)

584.18

4432

2589097.44

... More
Providing and fixing of the woodwork in the frames out of the Salwood as per the design drawings complete as required including a coat of the anti termite treament (Chloropyriophos 20%) over it. (NS)

6.08

110830

673849.68

... More
Supply Installation Testing & commissioning of 535 mm c/c (Arm to Arm) Fire Retardant fabric upholstered chair conforming to BIFMA standards. The chair to have tipup mechanism with back rocking / flexi back feature. The chair to have MS tubular framework welded together with continuous arc welding having minimum 2.5 mm thickness and suitably capped by polypropylene capping with groves specificaly designed for this purpose. The chair shall have powder coating of minimum 65 microns on all of the MS tubular framework . The seat shall have Polyurethane foam of density 55 ± 3 KG/Cum & Back to have density of 55 ± 3 Kg/Cum. The height of the back to be 900-1000 mm from the ground to top of back & for Seat to be 400-450 mm from the ground. The width of back rest to be minimum 450 mm and heighet of the back to be minimum 500 mm the width of the seat to the mimimum 450 mm and the depth minimum 460 mm. The rear of back shell & bottom of seat shell to be Polypropylene plastic in black colour Polypropylene plastic cover. The fabric of the chair should be 100% polyester of minimum 290 GSM. The wooden armrest to be of 80 mm, 400 mm length and 25mm thickness with melamie polished in black/ walnut colour. The armrest between two chairs in a row to be shared & at the both ends to be individual only. OEM of the product should have ISO 9001, 14001, 45001 certification. Including cost of suitable chemical expansion fastners as required of Hilti/Fischer make. Make Penworkers/ Featherlite /Godrej. Complete as per entire satisfaction of Engineer-in-Charge. (NS)

1608

17307

27830813.76

... More
Providing & Fixing 3M Etching LUMAR FILM including Plotter cutting. (Scotchcal™ ElectroCut™ Graphic Film Series 7725SE-400, Fluorescent Film) . Complete as per entire satisfaction of engineer-in-charge. (NS)

25.92

2092

54248.49

... More
Roller Blinds:- Roller Blinds: Providing and fixing roller blinds of approved make (Win Tree, Vista), shade and colour as approved by Engineer in Charge having blinds shall be Spring loaded resin operated media of polyesterable to limit the rays allowing natural illumination. Spring loaded resin mounting part made up of MS zinc coated of thickness of 2mm molded in PVC. The Idler pin made of zinc plated MS of 9mm outer dia surrounded by bearing balls to support blinds at other end. This bidirectional blind shall be operational by assistance of polyester cord. This polyester cord should be molded inside PVC beads of 4.5mm outer dia. The blinds shall be operational without any hindreace. (As per approved sample to the entire satisfaction of Engineer-in-Charge.) (NS)

45.6

2870

130887.96

... More
Providing and fixing vinyl or Polyster Textile wallpaper coverings with approved adhesive on existing plastered surface finished with putty , to give bubble free uniform surface. Any unevenness of the base surface shall be removed before fixing the wallcovering, all complete as per direction of Engineer-in-charge. (NS)

123.3

2906

358352.95

... More
Providing and fixing of 6mm thick annealed SGG Planilaque Evolution (premium GRIHA rated lacquered glass from Saint-Gobain) of approved color by Architect/ Client / Customer, fixed with SGG Glassmate Ultrafix (compatible neutral core silicon / double sided tape) on a perfectly leveled 12mm thick water proof marine plywood / MDF / Mineral fibre board which is mounted on the RCC wall/any other structure. Lacquered glass must be made industrially (via curtain coating process); opaque (if viewed against a support wall), coated with PU lacquer ; color consistency (measured by Minolta spectrophotometer CM5081); highly durable (passes PERSOZ hardness test for minimum 220 oscillatios); humid resistant (conforms to BS EN 1036 1999); environmentally friendly (no lead, no arsenic, no copper, noformaldehyde); appropriate recycled content (12% post industrial / 6% post consumer); compressive strenght (1000 MPa) & tensile strenght (40 MPa),same as float glass. all complete as per direction of Engineer-in-Charge. (NS)

96.82

9606

930094.55

... More
Providing & fixing of 5mm mirror glued with GE or equivalent silicon adhesive over 12mm BWR IS303 ply of make green ply, duro, century, fixed to walls with nylon sleeves on a framing. Complete as per direction of EIC. (NS)

56.04

5061

283649.26

... More
Wall / Ceiling painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. ( Two Coats) (DSR 13.83.2)

1945.74

138

270341.12

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80)

1945.74

151

295441.16

... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre (DSR 13.85.3)

1945.74

71

139995.99

... More
Providing & applying Parlina Texture Paint including base preparation and 2 coats of ultima as per manufacturer's specification and Complete in all respects and the entire satisfaction of engineer-in-charge. (NS)

2329.79

994

2316766.47

... More
Providing and fixing Brick tile cladding 9"x3" laid over 12mm to 15mm thick cement plaster including the cost of cement slurry laid at upto level V including the cost of scaffolding complete as per architectural drawings to the entire satisfaction of engineer in charge. (NS)

181.44

1217

220852.4

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.(DSR 22.5)

270.16

600

162201.36

... More
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:

-

-

-

... More
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2.35.3.1)

235.32

301

70991.34

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming ]coat of approved steel primer all complete. (DSR 10.2)

169171.45

130

22007513.93

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.

-

-

-

... More
Hot Finished welded types tube (DSR 10.16.1)

53367.58

189

10094477.76

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.

-

-

-

... More
On steel work. (DSR 13.52.1)

1014.74

235

238687.14

... More
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately):

-

-

-

... More
Flat Surface (DSR 12.31.1)

123.3

1672

206224.18

... More
Providing and fixing frame work of galvanized iron for ceiling curved in plan / section / as well as plain ceiling for suspended false ceiling which includes galvanised iron perimeter chanels of size 27 mm & 0.5 mm thick having one flange of 20 mm and another of 30 mm along with perimeter of the ceiling, fixing in brick wall / R.C.C. / partition with the help of rawal plugs and screws, suspending galvanized iron intermediate chanels of size 45 mm and 0.9 mm thick with two flanges of 15 mm each from the soffit at 1200 mm centers with steel galvanized iron hanger of size 25 mm x 25mm with fasteners, ceiling section of 0.5 mm thickness having size of 80 x 25 x 51 mm and made from hot deep galvanized sheet fixed to the intermediate chanel with the help of connecting clips and direction perpendicular to the intermediate channels at 450 mm centers. 12.5 mm dry walls screws at 230 mm centers, fixing screws mechanically either with screw diver or drilling machine with suitable attachement including scaffolding at all heights etc. completed as per directions of Engineer-in-charge. Including MS Pipe Cup Scaffolding upto any height including material cost & cost of erection meant for false ceiling a as per the profile of the ceiling complete in all respect.(Make: India Gypsum, Saint Gobain, Boral) (NS)

1929.77

571

1102188.14

... More
Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. (DSR 15.26)

520.05

102

53310.33

... More
Demolishing mud phaska in terracing and disposal of material within 50 metres lead. (DSR 15.27)

52.01

889

46268.62

... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR 15.60)

52.01

256

13357.21

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:

-

-

-

... More
With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (DSR 22.7.1)

520.06

1639

852440.75

... More
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. (DSR 12.55)

520.06

1657

862228.28

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.2.2)

25.57

10559

270017.15

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR 5.9.2)

135.78

819

111305.66

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6)

3835.46

104

402493.17

... More
Providing and fixing Unistone Da vinci series Cladding of the size 230x75 of Belgium brick / roman brick / London Brick made out of cultured stone. The thicknes of tile range from 20-25mm with deep grooves on back for adhesion. The tile sholuld have compresive strength of M-40. The top surface to be sealed wth acrylic laquer so that surface water absoeptionis less than 1%. The tiles to be fixed over rough cement mortar ( 1:3 i.e 1 cement 3 fine sand) with PU adhesive of PUA 21 of MYK Laticrete Rate is all inclusive. Complete item as per direction and satifaction of EIC. (NS)

81.6

8332

679954.03

... More
Providing and applying polyester based geo-textile protection fleece and 1.2mm thick Sika Sarnafil S-327-12L or equivalent with complete laying by Loosing laid – mechanically fastened method as per manufacturers method statement including overlapping, seam welding, detailing. It should be In rolls of 2x20 m and manufactured by spread coating process formulated for direct exposer to sunligh. it should include all types of coats of U bar termination along perimeter, termination bar along wall junctions and KTL washer's certificate for of life expectancy of 30 years and guarantee for 5 years. The item incudes the rates for all the required safety measures as per site requirement for fixing the sheet at the site of work. The work shall be got executed through authorised applicator of the product and the agency shall give guarantee of 5 years for the product.The agency shall make all the required safety measures for the workers, complete in all respects in all respects and to the entire satisfaction of the Engineer in charge. Note:- For the above item the contractual agency shall be required to submit waranttee certificate for a period of 05 years for the whole water proofing treatment. (NS)

319.1

3933

1255288.34

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. (DSR 12.52.1)

123.42

1851

228520.77

... More
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.

-

-

-

... More
10 x 80 mm (DSR 10.27.2)

536

133

71786.48

... More
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. (DSR 6.38)

21.44

9920

212688.44

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick (DSR 11.26.1)

973.24

1895

1844922.41

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.

-

-

-

... More
Size of Tile 600x600 mm (DSR 11.41.2)

265.77

1511

401714.01

... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.

-

-

-

... More
Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm (DSR 11.41A.3.1)

74.8

1425

106612.44

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 5.3)

0.99

11194

11082.9

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in

-

-

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2)

33.86

8860

300002.65

... More
Providing gola 75 x 75mm in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design

-

-

-

... More
In 75 mm x 75 mm deep chase (DSR 12.21.1)

270.08

296

80189.45

... More
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. (For the purpose of measurement the entire treated surface will be measured.) (DSR 22.6)

1235.5

670

828155.65

... More
Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat:

-

-

-

... More
With common burnt clay F.P.S. (non modular) brick tiles of class designation 10 (DSR 12.19.1)

1271.28

591

751326.48

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.

-

-

-

... More
For thickness of tiles 10 mm to 25 mm (DSR 15.23.1)

1271.28

71

90794.82

... More
Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. (DSR 16.92)

99.79

2130

212556.69

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.

-

-

-

... More
Size of Tile 1000x1000 mm (DSR 11.46.4)

164.38

2104

345890.04

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.

-

-

-

... More
In cement mortar (DSR 15.7.4)

2.51

2004

5031.47

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :

-

-

-

... More
Of area 3 sq. metres and below (DSR 15.12.1)

20.88

357

7460.22

... More
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.

-

-

-

... More
All kind of soil (DSR 2.28.1)

950.4

33

31581.79

... More
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (DSR 16.68)

472.5

945

446871.6

... More
Dismantling C.I or asbestos rain water pipe with fittings and clamps including stacking the material with in 50 metres lead : 100mm dia pipe (DSR 15.42.2)

18

75

1366.02

... More
PUBLIC HEALTH SERVICES

-

-

-

... More
1. Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 min width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (DSR 2.8)

-

-

-

... More
All kinds of Soil. (DSR 2.8.1)

59

253

14942.93

... More
2. Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : (2.10)

-

-

-

... More
All kinds of soil (2.10.1)

-

-

-

... More
Pipes, cables etc, not exceeding 80 mm dia. (2.10.1.1)

87

209

18250.86

... More
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia (2.10.1.2)

367.54

342

125933.91

... More
3. Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level : (DSR 4.1)

-

-

-

... More
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size (DSR 4.1.3)

17.04

7665

130624.89

... More
4. Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4)

-

-

-

... More
Cement mortar 1:4 (1 cement : 4 coarse sand) : (DSR 6.4.1)

4.76

9092

43278.16

... More
5. 12 mm cement plaster of mix : (DSR 13.1)

-

-

-

... More
1:4 (1 cement: 4 fine sand) (DSR 13.1.1)

51.64

337

17437.8

... More
6. Providing and fixing soil, waste and vent pipes : (DSR 17.35)

-

-

-

... More
100 mm dia (DSR 17.35.1)

-

-

-

... More
Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 (DSR 17.35.1.2)

335

1148

384871.45

... More
75mm diameter (DSR 17.35.2)

-

-

-

... More
Centrifugally cast (spun) iron socketed pipe as per IS: 3989 (DSR 17.35.2.2)

186

1153

214640.28

... More
7. Providing and fixing plain bend of required degree. DSR 17.39

-

-

-

... More
100 mm dia as per DSR No. 17.39.1

-

-

-

... More
Sand Cast Iron (S&S) pipe as per IS 3989 (DSR 17.39.1.2)

51

554

28287.66

... More
8. Providing and fixing heel rest sanitary bend (DSR17.40)

-

-

-

... More
100 mm dia (DSR 17.40.1)

-

-

-

... More
Sand cast iron S&S as per IS - 3989 (DSR 17.40.1.2)

54

533

28830.06

... More
9. Providing and fixing collar : (DSR17.57)

-

-

-

... More
100 mm (DSR17.57.1)

-

-

-

... More
Sand cast iron S&S pipe as per IS: 3989 (DSR 17.57.1.2)

89

499

44436.81

... More
75 mm (DSR 17.57.2)

-

-

-

... More
Sand cast iron S&S pipe as per IS: 3989 (DSR 17.57.2.2)

85

352

29942.95

... More
10. Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : (DSR 17.58)

-

-

-

... More
100 mm (DSR 17.58.1)

249

605

150707.25

... More
75 mm (DSR 17.58.2)

208

512

106504.32

... More
11. Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors (DSR 17.60)

-

-

-

... More
100 mm inlet and 75 mm outlet (DSR 17.60.2)

-

-

-

... More
Sand Cast Iron S&S as per IS- 3989 (DSR 17.60.2.1)

60

1921

115309.2

... More
12. Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 , including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : (DSR 17.61)

-

-

-

... More
100 mm dia (DSR 17.61.1)

34

693

23593.96

... More
75 mm dia (DSR 17.61.2)

18

499

8989.02

... More
13. Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, including cutting chases and making good the walls etc. (DSR 18.10)

-

-

-

... More
15 mm dia nominal bore (DSR 18.10.1)

50

356

17825.5

... More
20 mm dia nominal bore (DSR 18.10.2)

140

425

59568.6

... More
25 mm dia nominal bore (DSR 18.10.3)

225

536

120780

... More
32 mm dia nominal bore (DSR 18.10.4)

65

648

42184.35

... More
40 mm dia nominal bore (DSR 18.10.5)

195

789

154046.1

... More
14. Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe including painting with anticorrosive bitumastic paint, cutting chases and making good the wall: (DSR 18.11)

-

-

-

... More
15 mm dia nominal bore (DSR 18.11.1)

120

564

67773.6

... More
20 mm dia nominal bore (DSR 18.11.2)

200

618

123610

... More
15. Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17)

-

-

-

... More
20 dia nominal bore (18.17.1A)

35

525

18387.95

... More
25 dia nominal bore (DSR 18.17.1)

14

605

8478.4

... More
40 dia nominal bore (DSR 18.17.4)

14

803

11253.2

... More
16. Providing & fixing of ball valve (brass) of approved quality High or low Pressure, with plastic floats complete; (DSR 18.18)

-

-

-

... More
20mm dia nominal bore (DSR 18.18.2)

12

450

5400.12

... More
17. Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21)

-

-

-

... More
45 cm length (DSR 18.21.2)

-

-

-

... More
15 mm nominal bore (DSR 18.21.2.1)

29

95

2758.19

... More
18. Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : (DSR 18.46)

-

-

-

... More
20 mm dia nominal bore (DSR 18.46.2)

55

337

18559.2

... More
25 mm dia nominal bore (DSR 18.46.3)

22

427

9402.58

... More
40 mm dia nominal bore (DSR 18.46.5)

22

614

13513.5

... More
19. Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR 18.48)

34000

10

363800

... More
20. Providing and fixing C.P. Brass extension nipple (size 15mm x 50mm) of approved make and quality as per direction of Engineer-in-charge. (DSR 18.53A)

70

72

5094.6

... More
21. Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : (DSR 19.1)

-

-

-

... More
150 mm diameter (DSR 19.1.2)

92.06

677

62325.54

... More
200 mm diameter (DSR 19.1.3)

74.23

944

70084.25

... More
22. Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design (DSR 19.2)

-

-

-

... More
150 mm diameter S.W. pipe (DSR 19.2.2)

92.06

1147

105683.96

... More
200 mm diameter S.W. pipe (DSR 19.2.3)

79.23

1338

106034.3

... More
23. Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: (DSR 19.4)

-

-

-

... More
100x100mm size P Type (DSR 19.4.1)

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.4.1.1)

13

2634

34249.02

... More
24. Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: (DSR 19.30)

-

-

-

... More
Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : (DSR 19.30.3)

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.30.3.1)

19

9335

177370.7

... More
25. Providing and fixing of Wall Hung WC with PP soft close seat cover, Hinges, Accessories Set, Size: 370x540x410 mm. Make - Jaguar Model - CNS-WHT-959SPP or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge (NSR)

30

10722

321673.8

... More
26. Providing and fixing of Concealed Cistern Single Piece Slim Concealed Cistern Body with Installations Kit & “S-Type” drain pipe connection set for Wall Hung WC. Make - Jaguar Model -JCS-WHT-2400S or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

30

7120

213612.3

... More
27. Providing and fixing of Control Flush plate for concelaed cistern of wall hung WC. Make - Jaguar Model JCP-CHR-392415 or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in- Charge (NSR)

30

1913

57416.7

... More
28. Providing and fixing CP Hand Shower (Health Faucet) with 1 Meter Long Easy Flex Tube in Chrome Finish & Wall Hook Make - Jaguar Model ALD-565 or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

30

1415

42471.6

... More
29. Providing and fixing Regular body of Concealed Stop Cock Regular Body of Concealed Stop Cock Suitable for 15 mm Pipe Line with Protection Cap Model ALD-083 with Exposed Parts Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange with Seal Model ALD-083 & ALD-089) or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

30

1883

56511.9

... More
30. Providing and fixing Thin Rim Table Top Basin, Shape - Rectangular, Size: 530x420x140 mm Jaguar Model JDS-WHT-25907N or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

28

7461

208934.32

... More
31. Providing and fixing of Wall hung wash basin with full pedestal complete with C.I./MS brackets 32mm C.P. brass waste as per standard pattern including cutting and painting of brackets and making good the walls Make Cera Model CONCORD( Basin - 1022 or equivalent model of any other approved make. (NSR)

4

6577

26309.92

... More
32. Providing and fixing CP Brass Pressmatic Auto Close type Pillar Cock Jaguar Model PRS-031 or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

30

2795

83862.9

... More
33. Providing and fixing C.P. angle valve with wall flange of Make Jaguar Model KUP-35053PM or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

60

1721

103274.4

... More
34. Providing and fixing 1 mm thick stainless steel grating with frame for floor traps or drains of required pattern including cutting and making good the floors complete in all respect as per Makes approved by EIC. (NSR)

74

157

11664.62

... More
35. Providing and fixing C.P. brass toilet roll Holder with S.S Flap Make Jaguar Model AKP-35753PS or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

29

1873

54317.87

... More
36. Providing and fixing of C.P Brass towel ring Make Jaguar Model ACN-1121BN or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

26

1119

29117.92

... More
37. Providing and fixing soap dispensor 200ml with C.P. screw Make Jaguar Model ACN-1135N or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

28

1547

43317.96

... More
38. Providing and fixing superior quality mirror complete with studs including drilling holes or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

20.35

3488

70989.55

... More
39. Providing and fixing CP Bottle Trap (with Internal Partition) 32mm Size with 250mm & 190mm Long Wall Connection Pipes & Wall Flange Make Jaguar Model ALD-769L250x190 or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

36

1989

71632.44

... More
40. Providing and fixing C.P Long Body bib Cock with wall flange Make Jaguar Model CON-107KN or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

13

1671

21730.93

... More
41. Providing and fixing M.S girder of size 200x 100 mm for making a platform for placing PVC water storage tanks on terrace and painting the same with 1 coat of red oxide primer and 2 coats of black enamel paint complete in all respects. (NSR)

5000

105

525400

... More
42. Providing and fixing MS sheet 5 mm thick for supporting PVC overhead water storage tank on terrace and painting the same with 1 coat of red oxide primer and 2 coats of black enamel paint complete in all respects. (NSR)

1896

120

228752.4

... More
43. Dismantling of G.I/ C.I Pipe up to 20 mm dia in open or in chase including stacking the dismantled pipe and disposal of malba complete. (NSR)

160

48

7784

... More
44. Providing and fixing of Urinal white in colour with Jaguar Model URS-WHT-13261 or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

10

4792

47927.7

... More
45. Providing and fixing of Urinal Sensor with flushing valve with Jaguar Model SNR-STL-51093N or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

10

13802

138024.4

... More
46. Providing and fixing of Division Plates size of frosted glass in shape curved or rectangular, glass 8 mm Model - JSE-CHR-810 UC450 Make - Jaguar equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

8

5785

46283.68

... More
47. Providing and fixing of towel rail of Stainless Steel , 600 mm long Make Jaguar Model ACN-1111BSM or equivalent approved make in the same range of AOR complete in all respect and to the entire satisfaction of the Engineer-in-Charge. (NSR)

4

1564

6258.32

... More
48. Providing and fixing Stainless steel grab rail 32 mm round in shape complete in all respect as per Makes approved by EIC. (NSR)

16

1312

21001.28

... More
49. Providing and fixing P Trap complete in all respect. (NSR)

12

951

11419.08

-

-

-

... More
1. EQUIPMENT

-

-

-

... More
AIR COOLED SCROLL CHILLER

-

-

-

... More
Supply,Installation, Testing and commissioning of factory designed and pre-fabricated Vapor Compression refrigeration Air cooled chilling machines including one or more semihermetic / Hermatic compressors , of Scroll type , equipped with Air cooled condenser , meeting international standards like ECBC( test standard ARI 550/590-1998) and ASHRAE 90.1 2010 Standards - . Unit need to be mounted on steel frame as per specifications. Refrigerant shall be environmentally friendly R134A refrigerant. Chiller should be capable of unloading from 100 to 25% The compressor motor shall be suitable for operations on 415 +/- 10% Volts , 3 Phase , 50 Hz., and shall be direct coupled type . Cooling of the motor shall be effected by the refrigerant return.The chiller shall be DX type complete insulated with approved insulating material , Refrigerant piping shall be factory assembled as per the specifications detailed in the related section , or as per the specifications of the approved vendor , whichever is more stringent.The chiller assembly will be delivered with the initail charge of the refrigerant and compressor oil , Gauge panel, drive package , control panel and associated wiring , and all other accessories to make the chiller package ready for hook-up/commissioning. Chiller shall come with complete first charge of refrigerant and oil. (Either factory charged /site charged)

-

-

-

... More
The various other parameters governing the selection and capacity computations of the chiller package are as follows:

-

-

-

... More
Chilled water in : 12.22 Deg C , Chilled water out : 6.67 Deg C , Chiller Fouling factor :0.017600 M2 K/KW , Max Operating Pressure 150 psig (water side)

-

-

-

... More
Supply,Installation, Testing and commissioning of factory designed and pre-fabricated Vapor Compression refrigeration Air cooled water chilling machines of following actual capacity as described above and in the specifications.

-

-

-

... More
22 TR Nominal Capacity Air cooler scroll chiller as described above and in the specifications.

6

641497

3848987.58

... More
33 TR Nominal Capacity Air cooler scroll chiller as described above and in the specifications.

3

927027

2781083.1

... More
44 TR Nominal Capacity Air cooler scroll chiller as described above and in the specifications.

3

1188658

3565975.92

... More
1.2 CHILLED WATER PUMPS

-

-

-

... More
End suction

-

-

-

... More
Supply,installation,testing and commissioning of End suction split casing centrifugal pumps insulated for chilled water recirculation , complete with TEFC squirrel cage motors ( Insulation Class F) . The motor selected shall be energy efficient having efficiency (IE-2) at full load ranging between 91.5% to 94% in accordance with motor rating as per specification. The pump should be complete with the base plate, and all necessary accessories such as vibration isolators (VI pads ) , mechanical seals,gland drain connections mechanical coupling, coupling guards etc.Capacity of pump sets , nett head is as given below:All the pumps mentioned below shall be suitable for operation on 415+/- 15 % Volts , 50 Hz , 3 Phase AC power supply. & the minimum efficiency of pump shall be 75%)

-

-

-

... More
52.8 USGPM * 30 M head, PN-10 rated ;

6

114300

685801.56

... More
79.2 USGPM * 30 M head, PN-10 rated ;

3

114300

342900.78

... More
105 USGPM * 30 M head, PN-10 rated ;

3

122795

368386.56

... More
1.3 ELECTRICAL HOT WATER GENERATOR

-

-

-

... More
Supply,installation,testing and commissioning of Hot water generator complete as per specs.

-

-

-

... More
30 Kw ( Minimum 2 banks )

2

116184

232369.92

... More
35 Kw ( Minimum 2 banks )

2

116184

232369.92

... More
45 Kw ( Minimum 2 banks )

2

124791

249582.28

... More
65 Kw ( Minimum 2 banks )

2

124791

249582.28

... More
1.4 AIR HANDLERS

-

-

-

... More
Suppy, loading, unloading, lifting, shifting, storing, Installation ,Testing and commissioning of sheet metal sectionalised construction double skin AHU , each complete with all sections, coils, dampers and filters , and also complete with CHW Coils coils of copper tube and aluminum fins construction VSD compatible squirrel cage induction motor suitable for 415 ± 10% volts, 50 Hz, AC supply meeting criterion as per ASHRAE standard 90.1-2010 and high efficiency. DIDW centrifugal fan , belt drive package and vibration isolation (spring mounted).

-

-

-

... More
Include cost on account of all allied works such as Supply and Installation of 19 mm thick Neoprene Rubber Waffle Type Pads to be installed between the floor and the Air Handling Units. The neoprene pads shall be in accordance with the manufacturer's instructions for the size and weight distribution of the equipment supported.& Supply and Installation of additional Fire Resistant Fabric Flexible Connection to be installed outside betweeen the Fans outlet and the ducting to provide flexibilty of movement in case of a seismic event and to prevent transmission of vibration from the unit to the duct. The fabric should be of glassfiber with a silicon coating and extruded metal flanges. The fabric should conform to BS 476 Part 7 Class 1 and NFPA 701.

-

-

-

... More
11 TR / 4000 CFM Double skin floor mounted Horizontal AHU with, DIDW Forward/Backward curved centrifugal fan, 60 mm SP WG, 6 row deep chilled water coil, filters drier etc . MERV-8 , 3 phase motor (VFD compatible )-IP 55, drive set , mixing box and thermal break profile , weather proof canopy. ( Panel thickness 50 mm , Sheet 0.8 mm inner and outer )

2

228014

456029.54

... More
12 TR / 5000 CFM Double skin floor mounted Horizontal AHU with, DIDW Forward/Backward curved centrifugal fan, 60 mm SP WG, 6 row deep chilled water coil, filters drier etc . MERV-8 , 3 phase motor (VFD compatible )-IP 55, drive set , mixing box and thermal break profile , weather proof canopy. ( Panel thickness 50 mm , Sheet 0.8 mm inner and outer )

1

272105

272105.29

... More
14 TR / 6000 CFM Double skin floor mounted Horizontal AHU with, DIDW Forward/Backward curved centrifugal fan, 60 mm SP WG, 6 row deep chilled water coil, filters drier etc . MERV-8 , 3 phase motor (VFD compatible )-IP 55, drive set , mixing box and thermal break profile , weather proof canopy. ( Panel thickness 50 mm , Sheet 0.8 mm inner and outer )

1

304372

304372.89

... More
30 TR / 9000 CFM Double skin floor mounted Horizontal AHU with, DIDW Forward/Backward curved centrifugal fan, 60 mm SP WG, 6 row deep chilled water coil, filters drier etc . MERV-8 , 3 phase motor (VFD compatible )-IP 55, drive set , mixing box and thermal break profile , weather proof canopy. ( Panel thickness 50 mm , Sheet 0.8 mm inner and outer )

1

414400

414400.7

... More
30 TR / 9500 CFM Double skin floor mounted Horizontal AHU with, DIDW Forward/Backward curved centrifugal fan, 60 mm SP WG, 6 row deep chilled water coil, filters drier etc . MERV-8 , 3 phase motor (VFD compatible )-IP 55, drive set , mixing box and thermal break profile , weather proof canopy. ( Panel thickness 50 mm , Sheet 0.8 mm inner and outer )

1

423920

423920.53

... More
32 TR / 11000 CFM Double skin floor mounted Horizontal AHU with, DIDW Forward/Backward curved centrifugal fan, 60 mm SP WG, 6 row deep chilled water coil, filters drier etc . MERV-8 , 3 phase motor (VFD compatible )-IP 55, drive set , mixing box and thermal break profile , weather proof canopy. ( Panel thickness 50 mm , Sheet 0.8 mm inner and outer )

1

486750

486750.06

... More
33 TR / 11500 CFM Double skin floor mounted Horizontal AHU with, DIDW Forward/Backward curved centrifugal fan, 60 mm SP WG, 6 row deep chilled water coil, filters drier etc . MERV-8 , 3 phase motor (VFD compatible )-IP 55, drive set , mixing box and thermal break profile , weather proof canopy. ( Panel thickness 50 mm , Sheet 0.8 mm inner and outer )

2

501781

1003563.88

... More
Ceiling Suspended

-

-

-

... More
1.4.3 - 10 TR / 4500 CFM Double skin Ceiling suspended AHU with, DIDW Forward/Backward curved centrifugal fan, 40 mm SP WG, 6 row deep chilled water coil, filters drier etc . MERV-8 , 3 phase motor (VFD compatible )-IP 55, drive set ,

1

167689

167689.74

... More
1.5 Hiwall type Split AC

-

-

-

... More
Supply ,installation ,testing ,commissioning and handing over of Split type air-conditioning unit, each comprising of an outdoor unit and a single hiwall type indoor unit. Outdoor condensing unit shall comprise of compressors & air cooled condenser with fan. Evaporating unit shall consist of a centrifugal fan , multirows deep copper cooling coil with aluminium fins, thermostatic expansion valve etc.

-

-

-

... More
The enclosure shall be factory painted to a smooth finish. Refrigerant shallbe be R-410/R-407c/R32

-

-

-

... More
The units shall be suitable for 220V±10%, or 415V±10%, 50 Hz. Cost of single / three phase ( DP N / TP N) isolator at each indoor unit shall be included

-

-

-

... More
The equipment rate shall be inclusive of the installation of out door unit on MS frame duly painted and complete in all respect.

-

-

-

... More
1.5.1 -1.0 TR Hiwall type Split AC with Corded remote controller

9

32590

293315.76

... More
1.5 TR Hiwall type Split AC with Corded remote controller

4

39660

158641.8

... More
2.0 TR Hiwall type Split AC with Corded remote controller

2

47467

94935.62

... More
1.6 Refrigerant Piping

-

-

-

... More
Supply, installation, testing & commissioning of refrigerant grade copper tubing in ceiling / wall with support interconnecting outdoor and indoor units duly insulated with 19 / 13 mm thick elastomeric nitrile rubber tubing to prevent any heat loss, class 'O' covered with 7 miles thick glass cloth & finaly finished with UV coating, suitable sizes including chase cutting making good & clamping etc. :

-

-

-

... More
1.0 TR Hiwall unit ( liquid and suction line)

145

1017

147575.2

... More
1.5 TR Hiwall unit ( liquid and suction line)

75

1017

76332

... More
2.0 TR Hiwall unit ( liquid and suction line)

35

1174

41104.35

... More
1.7 Control and power wiring

-

-

-

... More
Supply, installation, testing & commissioning of contro and powerl cables MS counduiting duly complete with all fittings as per specification of suitable sizes from indoor units to outdoor units for the different capacities of split type air-conditioning .The wiring/cabling shall be as per the manufacturer's recommendations. All civil work like chase cutting of wall, floor and repair etc. shall be done by HVAC contractor.

-

-

-

... More
1.0 TR Hiwall unit

145

156

22714.25

... More
1.5 TR Hiwall unit

75

156

11748.75

... More
2.0 TR Hiwall unit

35

156

5482.75

... More
1.6 Tube Axial/Vane Flow Fan

-

-

-

... More
Supply of approved make of AMCA certified for sound and air, Long case Tube Axial/Vane fan long casing ,impeller, pressure casted almunium adjustable pith blades, motor suitable for maximum 1400 RPM, suitable for operating on 3 phase electric supply, 415+/-10% volts, 50 Hz cycles. The fan shall be including mounting bracket/mounting feet, spring isolator, one side Bird Screen, suitable for wall mounted / ceiling suspended installation, for ventilation , smoke Spill or pressurization duty. The fan shall be supplied with a suitable 3 phase, 4/6/8 Pole IP55 motor, Refer General Terms and Conditions, Technical Specifications and List of Makes Respectively.

-

-

-

... More
All exhaust Fans and fan motors used in normal as well in smoke extraction mode shall be suitably rated to handle high temperature ( 250 Deg C, for 2 Hrs. as per BSEN12101 standard)

-

-

-

... More
Fan out let velocity shall not exceed 18m/s.

-

-

-

... More
Sound power shall not be more than 85 DBA at 3 meter from fan & .

-

-

-

... More
Fan efficeincy shall not be less than 60%

-

-

-

... More
1.6.1 Smoke Extraction fans (IE-2, Class-H motor, with minimum efficiency criterion of fan as specified above)

-

-

-

... More
15000 CFM , 30 mm SP WG

2

78073

156147.04

... More
13000 CFM , 30 mm SP WG

1

71021

71021.22

... More
13500 CFM , 30 mm SP WG

1

71021

71021.22

... More
11500 CFM , 30 mm SP WG

1

63746

63746.1

... More
5100 CFM , 30 mm SP WG

1

52064

52064.26

... More
7000 CFM , 30 mm SP WG

1

53277

53277.59

... More
5000 CFM , 30 mm SP WG

1

45121

45121.9

... More
4600 CFM , 30 mm SP WG

1

45119

45119.96

... More
1.6.2 Replenishment air fans (IE-2, Class-F motor, with minimum efficiency criterion of fan as specified above)

-

-

-

... More
15000 CFM , 30 mm SP WG

2

70802

141604.58

... More
13000 CFM , 30 mm SP WG

1

63749

63749.01

... More
13500 CFM , 30 mm SP WG

1

63748

63748.04

... More
11500 CFM , 30 mm SP WG

1

58898

58898.61

... More
7000 CFM , 30 mm SP WG

1

48430

48430.1

... More
5100 CFM , 30 mm SP WG

1

47216

47216.77

... More
5000 CFM , 30 mm SP WG

1

41485

41485.8

... More
4600 CFM , 30 mm SP WG

1

41483

41483.86

... More
1.7 Propeller fan

-

-

-

... More
Suppy, loading, unloading, lifting, shifting, storing,,installation,testing and commissioning of Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with GI gravity louver , bird screen & speed Regulator

-

-

-

... More
1.7.1- 150 mm dia fan suitable for 220±5% volts 50 Hz cycles, 1 phase AC supply.

8

1459

11676

... More
1.8 Inline fan

-

-

-

... More
Suppy, loading, unloading, lifting, shifting, storing,,installation,testing and commissioning of Inline fan of the following capacity of approved make and specification. Fan shall be supplied with GI gravity louver , bird screen & speed Regulator

-

-

-

... More
75 CFM, 10 mm SP WG , fan suitable for 220±5% volts 50 Hz cycles, 1 phase AC supply.

1

7314

7314.04

... More
400 CFM, 10 mm SP WG , fan suitable for 220±5% volts 50 Hz cycles, 1 phase AC supply.

2

9737

19475.56

... More
500 CFM, 10 mm SP WG , fan suitable for 220±5% volts 50 Hz cycles, 1 phase AC supply.

2

9737

19475.56

... More
550 CFM, 10 mm SP WG , fan suitable for 220±5% volts 50 Hz cycles, 1 phase AC supply.

1

9737

9737.78

... More
650 CFM, 10 mm SP WG , fan suitable for 220±5% volts 50 Hz cycles, 1 phase AC supply.

1

10840

10840.19

... More
700 CFM, 15 mm SP WG , fan suitable for 220±5% volts 50 Hz cycles, 1 phase AC supply.

1

10840

10840.19

... More
850 CFM, 15 mm SP WG , fan suitable for 220±5% volts 50 Hz cycles, 1 phase AC supply.

1

13043

13043.07

... More
1.10 VARIABLE SPEED ( FREQUENCY) DRIVE PACKAGES

-

-

-

... More
Supply, Installation, Testing & Commissioning of following HVAC dedicated VFDs with IP 21 enclosures , complying with the tender specifications and having: 1. without active Harmonic filters THDi & THDv shall not be more than 405% 2. built-in EMC Filters (electromagnetic compatibility filters) for for VFDs for restriction of conducted emissions to comply with IEC61800: 3 (unrestricted distribution):2004 Category C 3, 3. Two-feedback PID controller having capability to simultaneously accept 3 feedback signals from PLC panel or CO2 sensors for process optimization and accordingly regulate the speed of the AHUs or pumps. 4. Provision for additional 2 PID controllers to control external devices such as chilled water modulating valve, fresh air damper, etc. thus reducing the number of I/Os in DDC Controllers & improving system reliability. 5. Automatic Energy Optimization / Load dependent flux optimization functionality for maximum energy savings. 6. MODBUS RTU as the communication protocol between BMS & VFDs. 7. VFDs not meeting above requirements shall provide external disconnect, external harmonic filters, additional external EMC Filters to comply with IEC61800: 3 (unrestricted distribution):2004 Category C 1 (50 m), external PLCs / DDCs to achieve 3 Feedback PID Controller functionality and external devices controlling capabilities.

-

-

-

... More
Variable Speed Drive package as described above and in specifications , suitable for 2.2 kW motor rating as per the specifications (3 Phase variable frequency output for AHU's blowers).

1

21311

21311.62

... More
Variable Speed Drive package as described above and in specifications , suitable for 3.0 kW motor rating as per the specifications (3 Phase variable frequency output for AHU's blowers).

4

26643

106574.64

... More
Variable Speed Drive package as described above and in specifications , suitable for 5.5 kW motor rating as per the specifications (3 Phase variable frequency output for AHU's blowers).

5

30903

154517.25

... More
1.11 Covered Cable tray

-

-

-

... More
Supplying and installing following size of perforated painted with powder coating M.S cable trays with perforation more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with M.S suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
150mm width X 50 mm depth X 1.6 mm thickness (DSR 4.1.2)

125

631

78897.5

... More
1.12 IAQ management system : Demand controlled ventilation package

-

-

-

... More
1.12.1 Supply, installation, Testing & Commissioning of Pressure independent IAeQ device consists airflow measuring console consisting of honey-comb pattern airflow straightner of thickness of minimum 60 microns and rapid average pitot tube for accurate airflow measurement. The console has framework of heavy guage extruded aluminium. The console is followed by Low leak extruded airfoil multiblade Volume Control Dampers. Made out of heavy gauge extruded aluminium airfoil blades and C type 115 mm deep frame with flange of 25 mm, complete with exposed gear drive, EPDM blade seal, with extended shaft suitable for Actuator mounting.

1.6

31902

51044.35

... More
Supply installation, Testing & Commissioning of of Microprocessor based Controller with BACnet MS/TP LAN communication protocol The controller is BTL certified, UL certified and CE certified. The controller has 4 UI, 1UO, 4 DO. The controller has internal performance assessment control charts for parameters based on temperature, airflow & pressure. The Actuator is of Belimo make with 5 n/m torque. The Actuator is built in controller casing only & has brushless motor. The Actuator has integrated position feedback. Noise of actuator is less than 35 dB (A). The airflow sensor is mounted on board only with range of negative 500 pascal to positive 500 pascal.

9

26994

242954.19

... More
Supply nstallation, Testing & Commissioning of communicating CO2 sensors with communication jack, a backlit-display and configurable graphic menus. For demand control ventilation

9

22086

198775.17

... More
2 PIPING

-

-

-

... More
2.1 EXPANSION TANK ( Open type )

-

-

-

... More
Supply, Install,Test and commission open type expansion tank ( MS faricated , 3.0 mm thick sheet) as per the specifications detailed earlier in the relevant section .The open type vessel expansion tank shall be complete with all accessories such as glass syphon to guage the water level from out side, so as to make it ready for installation and commissioning on site.The tank shall be insulated with the approved method of insulation , and shall be complete with water make-up connection and system

-

-

-

... More
Water expansion tank as described above duly insulated with 25 mm thick insulating material ( EPS, TF quality, Density 24 Kg/cum ) and finished with sand cement plaster as specified.and as mentioned in the drawings and specifications.

-

-

-

... More
1000 Ltr .open vessel Expansion Tank duly insulated and with all accessories.

4

48650

194600

... More
2.2 AUTO AIR VENT

-

-

-

... More
Supply, installation ,testing and commissioning of Auto Air vents,at the highest points in the chilled water piping , as per approved makes and specifications.20 mm Dia Auto Air Vents. 20 mm dia ball valve will be provided along with auto air vent

40

2311

92474

... More
2.3 CHILLED WATER PIPING (Including Insulation)

-

-

-

... More
Supply, laying / fixing , testing and commissioning of following nominal sizing of chilled water piping ( with necessories clamps , vibration isolator and fittings but not included valves ) duly insulated wth closed cell elastomeric nitrile rubber of minimum 45 KG/cum density, thermal conductivity 0.037 W/mk, at 20 degre mean temperature class O insulation applied with suitable adhesive complete as er specification and as required complete in all respect and covered with 7 miles thick glass cloth & finished with fire proof protective coating as per specifications (DSR 16.2)

-

-

-

... More
Note : The ppipe of size 150 mm and below shall be MS C classas per IS 1239 and pipe size above 150 mm shall be welded black sheet pipe heavy class as per IS : 3589 , from minimum 6.35 mm thick MS sheet pipe upto 350 mm dia and from minimum 7.0 mm thick MS sheet pipe of 400 mm dia and above

-

-

-

... More
100mm dia ( 32 mm thick insulation) (DSR 16.2.8)

205

3114

638390.5

... More
80mm dia ( 32 mm thick insulation) (DSR 16.2.9)

415

2326

965360.55

... More
65mm dia ( 32 mm thick insulation) (DSR 16.2.10)

235

1874

440561.55

... More
50mm dia ( 32 mm thick insulation) (DSR 16.2.11)

90

1622

146060.1

... More
40mm dia ( 32 mm thick insulation) (DSR 16.2.12)

116

1313

152374.12

... More
32mm dia ( 19 mm thick insulation) (DSR 16.2.13)

8

1094

8752.96

... More
25mm dia ( 19 mm thick insulation) (DSR 16.2.14)

85

908

77189.35

... More
2.4 Providing and fixing in position the following Insulated butterfly valves.Valves beyond 350mm dia shall be gear operated. ( Rating - PN-10) (DSR 16.7.1)

-

-

-

... More
80mm dia (DSR 16.7.1.5)

20

5064

101281.4

... More
65mm dia (DSR 16.7.1.6)

38

4733

179886.3

... More
50mm dia (DSR 16.7.1.7)

8

4314

34518.48

... More
2.5 Providing and fixing in position the following Insulated ball valves.

-

-

-

... More
25mm dia

36

782

28162.44

... More
2.6 Providing and fixing of insulated 3 way modulating control valve with thermostat, return air temperature sensor and wiring for AHU and FCU having 3 way modulating control function, 24V / 220 V actuator . (Rating PN-10)

-

-

-

... More
80mm dia

2

28730

57461.48

... More
65mm dia

3

22635

67907.61

... More
50mm dia

4

16256

65027.52

... More
40mm dia

1

13918

13918.77

... More
2.7 Balancing Valve with Built in measuring facility with CI body flanged construction with EPDm coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. (DSR 16.7.2)

-

-

-

... More
80mm dia (DSR 16.7.2.5)

8

14390

115125.52

... More
65mm dia (DSR 16.7.2.6)

9

12879

115916.67

... More
50mm dia (DSR 16.7.2.7)

4

11222

44889.04

... More
40mm dia (DSR 16.7.2.8)

1

7956

7956.63

... More
2.8 Providing and fixing in position the following insulated check valves as per the specifications.(Rating PN-10)

-

-

-

... More
80mm dia (DSR 16.7.3.5)

6

4464

26785.44

... More
65mm dia (DSR 16.7.3.6)

6

3951

23706.9

... More
2.9 FLEXIBLE PIPE CONNECTORS

-

-

-

... More
Providing and fixing in position the following Flexible connection on pipes with guide bolts.(Rating PN-10)

-

-

-

... More
80mm dia

24

5730

137543.28

... More
65mm dia

24

4793

115055.28

... More
2.10 Y- STRAINERS

-

-

-

... More
Providing and fixing in position the following Insulated Y-Strainers ( Rating - PN-10)

-

-

-

... More
80mm dia (DSR 16.7.4.5)

5

10326

51633.45

... More
65mm dia (DSR 16.7.4.6)

9

8319

74873.25

... More
50mm dia (DSR 16.7.4.7)

4

6157

24628.56

... More
2.11 Providing and fixing in position of approved make flow switch complete with interconnecting copper control wiring at the condenser and evaporator outlet of each chiller packaged machine. (NSR)

9

1754

15788.88

... More
2.12 Providing and fixing in position the industrial dial type pressure gauges with gun metal valves and isolation ball valve. (to be installed at all critical locations in the plant room.) (DSR 16.8)

64

1249

79988.48

... More
2.13 Providing and fixing in position the mercury-in- glass industrial type thermometers with isolation ball valve. (to be installed at all critical locations in the plant room.) (DSR 16.9)

40

1089

43597.6

... More
2.14 Insulated Drain Piping

-

-

-

... More
Providing and fixing and in position the following UPVC pipes for condensate drain , cut to required length and installed with all fittings.

-

-

-

... More
Drain pipes shall be insulated with 9 mm thick Nitrile foam insulation in pipe sections as per specifications detailed earlier in the relevant section.

-

-

-

... More
25 mm dia ( with insulation)

70

295

20705.3

... More
32 mm dia ( with insulation)

20

369

7394.8

... More
40 mm dia ( with insulation)

20

430

8601.4

... More
2.15 CHILLED WATER PIPING (Including Insulation)- BURRIED

-

-

-

... More
Providing and fixing in position the following MS C class chilled water piping cut to required length and installed with welded joints (USE RECTIFIER AS SPECIFIED), including all necessary fittings such as elbows, tees etc. and confirming to the specifications as detailed in the relevant chapter in the document. Pipes will be accepted in order of preference (Factory fabricated/Fabricated out of 6mm thick plates duly rolled in a workshop and welded:for pipes beyond 350mm dia).

-

-

-

... More
Chilled water pipes shall be insulated with 50 MM THICK PUF insulation covered with HDPE cladding

-

-

-

... More
Cost of excavation and back filling of trench for chilled water piping shall also be included in the cost of piping

-

-

-

... More
100mm dia

100

5934

593433

... More
80mm dia

280

4168

1167132.4

... More
3. AIR DISTRIBUTION

-

-

-

... More
3.1 Factory fabricated duct

-

-

-

... More
Supply,Fabrication , Installation and testing of sheet metal ducts in accordance with the approved shop drawings and specifications , and shall also confirm to the SMACNA specifications.

-

-

-

... More
Ducts installed shall have intermediate stiffners if any one size of the duct is more than 750mm. Stiffners spacing shall not be more than 600mm along the maximum size of the duct. Stiffner dia shall be atleast with 10mm dia rod with 4 Nos. washer & nuts on either side (2 Nos. on top & 2 Nos. on bottom). If duct sizes (AxB) are more than 1000mm , stiffners are to be installed vertically as well as horizontally at a spacing of 500mm with 12mm dia rod with washers & double nuts on either side.

-

-

-

... More
All mating Flanges , corners shall be factory fabricated & shall be installed with corner bolts , 12mm gasket between two joints & Factory fabricated clamps . Clamp spacing shall not be more than 150mm.

-

-

-

... More
All Tranverse & longitudinal joints to be sealed with Silicon Sealant (Tranparent) before testing & before cutting of collars, branches, insulation either by light for low pressure ducts or with smoke for high pressure ducts.

-

-

-

... More
751-1200 mm GSS (24G) (DSR 16.12.1.1)

3150

1128

3555090

... More
1201 - 1800 mm GSS (22G) (DSR 16.12.1.2)

785

1319

1036074.4

... More
1801-2100 mm GSS (20 G ) (DSR 16.12.1.3)

160

1443

230904

... More
2101 mm & above (18 G) (DSR 16.12.1.4)

40

1918

76744.8

... More
3.2 Site Fabricated duct

-

-

-

... More
Supply,Fabrication , Installation and testing of sheet metal ducts in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces

-

-

-

... More
0-750 mm GSS - 24G (DSR 16.12.2.1)

310

1105

342739.1

... More
751-1500 mm GSS - 22G (DSR 16.12.2.2)

235

1284

301812.85

... More
1501-1800 mm GSS - 20G (DSR 16.12.2.3)

170

1702

289392.7

... More
1801 mm & above GSS - 18G (DSR 16.12.2.4)

80

1873

149895.2

... More
3.3. BOX TYPE DUCT DAMPERS

-

-

-

... More
Supply, Installation and Testing of multiblade box type GSS construction damper for ducts , to be provided with suitable links and quadrants for control of volume of air. Frame 18G, Blade 20G (DSR 16.13)

9

7363

66267.63

... More
3.4 COLLAR DAMPERS

-

-

-

... More
Supply, Installation and Testing of multiblade type louver damper of Aluminum construction for collars to be provided with suitable links , levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution as per approved shop floor drawings and specifications. (NSR)

64

4582

293301.12

... More
3.5 LINEAR GRILL (FIXED BAR)

-

-

-

... More
Supply,Installation,Testing and commissioning of supply and return air grille as per approved colour , shop floor drawings & specifications. (General Detail drawing to be submitted for fixing of grill).

-

-

-

... More
Linear Fresh / exhaust air grills shall be extruded Aluminum construction with fixed horizontal bars of 0 ° or 15 ° inclination with one way deflection and flanges on all sides. The thickness of fixed bar louvers shall be 5 mm in front and the flange shall be 15/20 mm wide with round edges. The register shall be suitable for concealed fixing and horizontal bars of the register shall be mechanically crimped from the back to hold them. Spacers between two louvers shall be powder coated black in colour. Fixing arrangement of grills to be submitted for approval prior to installation.

-

-

-

... More
Powder coated extruded aluminium grilles of approved shade and colour. (DSR 16.16)

73

6175

450844.35

... More
3.6 Flexible canvass connection made of fibreglass weave having silver grey silicon rubber coating, Flexible connection shall be air tight & water proof and withstand high temperature application, non flammable and does not support combustion. Flexible connection shall be complete with flanges made out of 22G G.S.S sheet on both sides for connection to unit and duct complete with nuts, bolts etc.

47

1453

68322.02

... More
3.7 'Supply, Installation and testing of GI constructed back draft damper with brass bushes in accordance with the approved shop drawings and specifications. ( 16G frame, 18G Blade )

20

8224

164495.4

... More
3.8 Jet Nozzle

-

-

-

... More
Supply, Installation and Testing and commissioning of powder coated Aluminum construction eye ball type jet nozzle with key operated butterfly damper of approved shade and colour as per specification.

-

-

-

... More
300 mm dia ( 150 mm nozzle )

28

2429

68028.24

... More
3.9 MOTORIZED FIRE AND SMOKE DAMPERS

-

-

-

... More
Supply,Installation, Testing and commissioning of motorized combination fire and smoke damper (spring return type) of approved make of atleast 120 minute fire rating .The fire damper shall be complete with electronic temperature sensor and electrically operated actuator .The fire dampers shall be located in the Replenishment / Smoke exhaust / AHU outlet The control panel will be such located that the reset can be easily done These combination smoke and fire dampers shall be interlocked with the building management system for fire detection / HVAC and shall trip/close in the event of fire / smoke in the respective zone .

-

-

-

... More
Damper shall be supplied with Min. 500mm sleeve made out of 0.8mm thick GI sheet. Thickness of damper blade shall not be less than 0.8mm. The blades shall be filtted in chrome plated bush & with suitable linkages

-

-

-

... More
GI Bare Fire Dampers (DSR 16.20.1)

30

11138

334159.8

... More
Control panel actuator , including Electrical,spring return type ON/OFF actuator,remote indication of the fire damper position. (DSR 16.20.2)

36

10395

374243.76

... More
Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers.

4

31135

124540.12

... More
3.10 SUPPLY AIR DIFFUSER

-

-

-

... More
Supplying, fixing, testing commissioning of supply air diffusers of powder coated aluminium equipped with removable core and aluminium volume control dampers of approved colour and shade. & as per specifications (DSR 16.17)

2

12732

25464.56

... More
3.11 RETURN AIR DIFFUSER

-

-

-

... More
Supplying, fixing, testing commissioning of Return air diffusers of powder coated aluminium equipped with removable core but without volume control dampers of approved colour and shade. & as per specifications (DSR 16.18)

2

8486

16972.9

... More
4. INSULATION

-

-

-

... More
4.1 DUCT ACOUSTIC TREATMENT

-

-

-

... More
Supply and Application of acoustic lining within the supply and return air duct with 25 mm thick glasswoll (32 Kg/cum density) with GI framing (25 x 25 mm GI section of 1.25 mm thick) , RP tissue and covered with 0.5 mm aluminum perforated sheet approved as per specifications and drawings.

-

-

-

... More
25mm thick (DR 16.21)

3435

739

2541419.1

... More
4.2 DUCT LINE THERMAL INSULATION

-

-

-

... More
Supply and Application of external thermal insulation of ducting with approved sample of nitril rubber insulating material covered with factory reinforced UL approved Glass cloth class-O color as per client as per specifications. OEM guide line to be followed for installatin as per specification. (NSR)

-

-

-

... More
13 mm thick

3150

631

1989162

... More
4.3 EXPOSED DUCT LINE THERMAL INSULATION

-

-

-

... More
Supply and Application of external thermal insulation of ducting with approved sample of nitril rubber / XLPE insulating material covered with protective coating UL apporved class 'O' covered with 7 miles thick glass cloth & finaly finished with UV coating as per specifications. (NSR)

-

-

-

... More
25 mm thick

975

1165

1136508.75

... More
4.4 Under deck insulation

-

-

-

... More
Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building

-

-

-

... More
50 mm thick with fibre glass wool (DSR 12.34 ( civil)

1000

684

684070

... More
5.ASSOCIATED ELECTRICAL WORKS

-

-

-

... More
The panel shall be complete with DOL / SD starter as per kW rating of the serviced motor, Terminal block for power distribution, Contactor, over load relay with built in single phasing protection , Phase indicating lights and indicating light for ON status,Digital voltmeter and digital ammeter with selector switches, Time delay relay for delayed automatic restart of air handling unit motor, Wiring for microswitch for stopping the fan when fire damper closes, For on/off/remote and local operation, 3 pole single throw switch shall be provided in each AHU panel to facilitate override of the automatic operation , All starters shall be provided with suitable potential free contract for connections to the Building Automation System , 220 / 24 V Transformer (if required for the performance of the system) ..All panels shall be suitable to receive and process the signal from the PLC panel and fire zonel panel/ zonal fire control module (as the case may be) Potential free NO-NC contact shall be provided in each panel. Inter connecting and looping shall also be done accordingly. The panel as described above shall be either wall mounted or floor mounted.

-

-

-

... More
EL-MCC-AC-1

-

-

-

... More
Incoming

-

-

-

... More
1 no. 63 amp 4P MCCB

-

-

-

... More
Phase indicating lights with control fuses.

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
Digital voltmeter with SS with control fuses.

-

-

-

... More
Digital ammeter with SS and CT's.

-

-

-

... More
80 amp TPN Aluminum BB with heat shrinkable insulation colored sleeves.

-

-

-

... More
Outgoings

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
ON/OFF Push Button with indication lights on each feeder

-

-

-

... More
Auto / Manual Switch for BMS integration on on each feeder

-

-

-

... More
1 nos. 50 amp,TP MCB with SPPR ( with space for VFD with adequate ventilation with fan ) and DOL starter with by-pass arrangement ( 5.5 KW)

-

-

-

... More
1 nos. 32 amp,TP MCB with SPPR ( with space for VFD with adequate ventilation with fan ) and DOL starter with by-pass arrangement ( 3.0 KW )

-

-

-

... More
6 no. 6 Amp. DP MCB with transformer suitable for 220 V to 24V AC

-

-

-

... More
2 no. 6 Amp. DP MCB

-

-

-

... More
Necessary control wiring with potential free NO+NC contact , relay etc. on each outgoing to receive signal from fire alarm module to energise fan in case of fire.

-

-

-

... More
Panel as described above and in drawings.

4

81685

326741.2

... More
EL-MCC-AC-2

-

-

-

... More
Incoming

-

-

-

... More
1 no. 80 amp 4P MCCB

-

-

-

... More
Phase indicating lights with control fuses.

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
Digital voltmeter with SS with control fuses.

-

-

-

... More
Digital ammeter with SS and CT's.

-

-

-

... More
100 amp TPN Aluminum BB with heat shrinkable insulation colored sleeves.

-

-

-

... More
Outgoings

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
ON/OFF Push Button with indication lights on each feeder

-

-

-

... More
Auto / Manual Switch for BMS integration on on each feeder

-

-

-

... More
2 nos. 20 amp,TP MCB with SPPR ( with DOL starter, 2.2 KW)

-

-

-

... More
2 nos. 50 amp,TP MCB with SPPR ( with DOL starter, 5.5 KW)

-

-

-

... More
2 no. 10 Amp. DP MCB with transformer suitable for 220 V to 24V AC

-

-

-

... More
Necessary control wiring with potential free NO+NC contact , relay etc. on each outgoing to receive signal from fire alarm module to energise fan in case of fire.

-

-

-

... More
Panel as described above and in drawings.

4

82967

331870.84

... More
EL-MCC-AC-3

-

-

-

... More
Incoming

-

-

-

... More
1 no. 315 amp 4P MCCB

-

-

-

... More
Phase indicating lights with control fuses.

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
Digital voltmeter with SS with control fuses.

-

-

-

... More
Digital ammeter with SS and CT's.

-

-

-

... More
400 amp TPN Aluminum BB with heat shrinkable insulation colored sleeves.

-

-

-

... More
Outgoings

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
ON/OFF Push Button with indication lights on each feeder

-

-

-

... More
Auto / Manual Switch for BMS integration on on each feeder

-

-

-

... More
5 nos. 160 amp,TPN MCCB

-

-

-

... More
3 nos. 50 amp,TP MCB with SPPR ( with DOL starter, 5.5 KW)

-

-

-

... More
2 no. 6 Amp. DP MCB

-

-

-

... More
Necessary control wiring with potential free NO+NC contact , relay etc. on each outgoing to receive signal from fire alarm module to energise fan in case of fire.

-

-

-

... More
Panel as described above and in drawings.

1

146293

146293.47

... More
EL-MCC-AC-4

-

-

-

... More
Incoming / outgoing

-

-

-

... More
1 no. 63 amp 4P MCCB

-

-

-

... More
Phase indicating lights with control fuses.

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
Digital voltmeter with SS with control fuses.

-

-

-

... More
Digital ammeter with SS and CT's.

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
ON/OFF Push Button with indication lights on each feeder

-

-

-

... More
Auto / Manual Switch for BMS integration on on each feeder

-

-

-

... More
1 nos. 20 amp,TP MCB with SPPR ( with space for VFD with adequate ventilation with fan ) and DOL starter with by-pass arrangement ( 2.2 KW)

-

-

-

... More
1 no. 6 Amp. DP MCB with transformer suitable for 220 V to 24V AC

-

-

-

... More
Necessary control wiring with potential free NO+NC contact , relay etc. on each outgoing to receive signal from fire alarm module to energise fan in case of fire.

-

-

-

... More
Panel as described above and in drawings.

1

34043

34043.32

... More
Main Incomer panel for HVAC panels

-

-

-

... More
INCOMING:

-

-

-

... More
1 no. 320A 415V, 4P 25kA MCCB with Microprocessor based release having O/L, S/C/ , E/F , O/V, U/V Protection and ON /OFF/TRIP Indications with MCB.

-

-

-

... More
1 no. Digital type Multifunction Meters to show (V, A, kWh, KVAh, KW, KVA, KVAR, PF, Hz.) with cast resin CTs.

-

-

-

... More
1 Set of LED phase indicating lamps with MCB protection.

-

-

-

... More
BUSBARS:

-

-

-

... More
1 Set of TPN aluminium bus bar of minimum of 400 A capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc, for withstanding fault level of 35KA for 1 Sec.

-

-

-

... More
OUTGOING:

-

-

-

... More
1 no. 250A 415V, TP+Neutral Link MCCB of 25kA with O/L, S/C protection.

-

-

-

... More
1 no. 63A 415V, TP+Neutral Link MCB of 25kA with O/L, S/C protection.

-

-

-

... More
1 no. 40A 415V, TP+Neutral Link MCB of 25kA with O/L, S/C protection.

-

-

-

... More
1 no. 25A 415V, TP+Neutral Link MCB of 25kA with O/L, S/C protection.

-

-

-

... More
1 no. 63A 415V, TP+Neutral Link MCCB as Spare.

1

172042

172042.94

... More
EL-MCC-AC-2- PG college Audi

-

-

-

... More
Incoming

-

-

-

... More
1 no. 63 amp 4P MCCB

-

-

-

... More
Phase indicating lights with control fuses.

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
Digital voltmeter with SS with control fuses.

-

-

-

... More
Digital ammeter with SS and CT's.

-

-

-

... More
80 amp TPN Aluminum BB with heat shrinkable insulation colored sleeves.

-

-

-

... More
Outgoings

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
ON/OFF Push Button with indication lights on each feeder

-

-

-

... More
Auto / Manual Switch for BMS integration on on each feeder

-

-

-

... More
1 nos. 50 amp,TP MCB with SPPR ( with space for VFD with adequate ventilation with fan ) and DOL starter with by-pass arrangement ( 5.5 KW)

-

-

-

... More
3 no. 6 Amp. DP MCB with transformer suitable for 220 V to 24V AC

-

-

-

... More
1 no. 6 Amp. DP MCB

-

-

-

... More
Necessary control wiring with potential free NO+NC contact , relay etc. on each outgoing to receive signal from fire alarm module to energise fan in case of fire.

-

-

-

... More
Panel as described above and in drawings.

1

59369

59369.54

... More
EL-MCC-AC-4 - PG college Audi

-

-

-

... More
Incoming

-

-

-

... More
1 no. 63 amp 4P MCCB

-

-

-

... More
Phase indicating lights with control fuses.

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
Digital voltmeter with SS with control fuses.

-

-

-

... More
Digital ammeter with SS and CT's.

-

-

-

... More
80 amp TPN Aluminum BB with heat shrinkable insulation colored sleeves.

-

-

-

... More
Outgoings

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
ON/OFF Push Button with indication lights on each feeder

-

-

-

... More
Auto / Manual Switch for BMS integration on on each feeder

-

-

-

... More
2 nos. 50 amp,TP MCB with SPPR ( with DOL starter, 7.5 KW)

-

-

-

... More
2 no. 6 Amp. DP MCB with transformer suitable for 220 V to 24V AC

-

-

-

... More
Necessary control wiring with potential free NO+NC contact , relay etc. on each outgoing to receive signal from fire alarm module to energise fan in case of fire.

-

-

-

... More
Panel as described above and in drawings.

1

58685

58685.52

... More
EL-MCC-AC-5 - PG college Audi

-

-

-

... More
Incoming

-

-

-

... More
1 no. 400 amp 4P MCCB

-

-

-

... More
Phase indicating lights with control fuses.

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
Digital voltmeter with SS with control fuses.

-

-

-

... More
Digital ammeter with SS and CT's.

-

-

-

... More
450 amp TPN Aluminum BB with heat shrinkable insulation colored sleeves.

-

-

-

... More
Outgoings

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
ON/OFF Push Button with indication lights on each feeder

-

-

-

... More
Auto / Manual Switch for BMS integration on on each feeder

-

-

-

... More
5 nos. 200 amp,TPN MCCB

-

-

-

... More
3 nos. 50 amp,TP MCB with SPPR ( with DOL starter, 7.5 KW)

-

-

-

... More
2 no. 6 Amp. DP MCB

-

-

-

... More
Necessary control wiring with potential free NO+NC contact , relay etc. on each outgoing to receive signal from fire alarm module to energise fan in case of fire.

-

-

-

... More
Panel as described above and in drawings.

1

165112

165112.26

... More
EL-MCC-AC-3

-

-

-

... More
Incoming

-

-

-

... More
1 no. 200 amp 4P MCCB

-

-

-

... More
Phase indicating lights with control fuses.

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
Digital voltmeter with SS with control fuses.

-

-

-

... More
Digital ammeter with SS and CT's.

-

-

-

... More
240 amp TPN Aluminum BB with heat shrinkable insulation colored sleeves.

-

-

-

... More
Outgoings

-

-

-

... More
Breaker ON/OFF/TRIP indicating lights.

-

-

-

... More
ON/OFF Push Button with indication lights on each feeder

-

-

-

... More
Auto / Manual Switch for BMS integration on on each feeder

-

-

-

... More
5 nos. 100 amp,TPN MCCB

-

-

-

... More
3 nos. 50 amp,TP MCB with SPPR ( with DOL starter, 4.0 KW)

-

-

-

... More
2 no. 6 Amp. DP MCB

-

-

-

... More
Necessary control wiring with potential free NO+NC contact , relay etc. on each outgoing to receive signal from fire alarm module to energise fan in case of fire.

-

-

-

... More
Panel as described above and in drawings.

2

116108

232216.18

... More
5.1 Main Incomer panel for HVAC panels

-

-

-

... More
INCOMING:

-

-

-

... More
1 no. 250A 415V, 4P 25kA MCCB with Microprocessor based release having O/L, S/C/ , E/F , O/V, U/V Protection and ON /OFF/TRIP Indications with MCB.

-

-

-

... More
1 no. Digital type Multifunction Meters to show (V, A, kWh, KVAh, KW, KVA, KVAR, PF, Hz.) with cast resin CTs.

-

-

-

... More
1 Set of LED phase indicating lamps with MCB protection.

-

-

-

... More
BUSBARS:

-

-

-

... More
1 Set of TPN aluminium bus bar of minimum of 300 A capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc, for withstanding fault level of 35KA for 1 Sec.

-

-

-

... More
OUTGOING:

-

-

-

... More
1 no. 160A 415V, TP+Neutral Link MCCB of 25kA with O/L, S/C protection.

-

-

-

... More
1 no. 63A 415V, TP+Neutral Link MCB of 25kA with O/L, S/C protection.

-

-

-

... More
1 no. 40A 415V, TP+Neutral Link MCB of 25kA with O/L, S/C protection.

-

-

-

... More
1 no. 63A 415V, TP+Neutral Link MCB as Spare.

2

109481

218963.92

... More
Main Incomer panel for HVAC panels

-

-

-

... More
INCOMING:

-

-

-

... More
1 no. 400A 415V, 4P 25kA MCCB with Microprocessor based release having O/L, S/C/ , E/F , O/V, U/V Protection and ON /OFF/TRIP Indications with MCB.

-

-

-

... More
1 no. Digital type Multifunction Meters to show (V, A, kWh, KVAh, KW, KVA, KVAR, PF, Hz.) with cast resin CTs.

-

-

-

... More
1 Set of LED phase indicating lamps with MCB protection.

-

-

-

... More
BUSBARS:

-

-

-

... More
1 Set of TPN aluminium bus bar of minimum of 500 A capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc, for withstanding fault level of 35KA for 1 Sec.

-

-

-

... More
OUTGOING:

-

-

-

... More
1 no. 320A 415V, TP+Neutral Link MCCB of 25kA with O/L, S/C protection.

-

-

-

... More
2 no. 63A 415V, TP+Neutral Link MCB of 25kA with O/L, S/C protection.

-

-

-

... More
1 no. 40A 415V, TP+Neutral Link MCB of 25kA with O/L, S/C protection.

-

-

-

... More
1 no. 32A 415V, TP+Neutral Link MCB of 25kA with O/L, S/C protection.

-

-

-

... More
1 no. 160A 415V, TP+Neutral Link MCCB as Spare.

1

224177

224177.25

... More
CABLING (POWER )

-

-

-

... More
Power Cabling and Earthing:

-

-

-

... More
5.2 S/I/T/C of Aluminum conductor cables PVC insulated PVC sheathed , armoured cable of 1.1KV grade with termination glands and GI earthing (flats / strips / wires, as may be applicable as per electric rules : Earthing system shall comply to IS: 3043-1987.) , identification tags , clamps , and saddles. (FRLS-H)

-

-

-

... More
4Cx 25 Sqmm

125

374

46826.25

... More
3.5Cx 150 Sqmm

50

1396

69813

... More
3.5Cx 120 Sqmm

75

1199

89978.25

... More
3.5Cx 70 Sqmm

225

771

173607.75

... More
3.5Cx 50 Sqmm

130

574

74629.1

... More
3.5Cx 35 Sqmm

260

433

112829.6

... More
5.3 S/I/T/C of Copper conductor cables PVC insulated PVC sheathed , armoured cable of 1.1KV grade with termination glands and GI earthing (flats / strips / wires, as may be applicable as per electric rules : Earthing system shall comply to IS: 3043-1987.) , identification tags , clamps , and saddles. (FRLS-H)

-

-

-

... More
3Cx06 Sqmm

80

427

34172

... More
3Cx04 Sqmm

395

370

146430.45

... More
3Cx2.5 Sqmm

225

354

79688.25

... More
4Cx 6 Sqmm

38

576

21888.76

... More
4Cx 10 Sqmm

230

867

199621.6

... More
4Cx 16 Sqmm

95

1271

120812.45

... More
5.4 Supply & laying of following grade with aluminium/Copper conductor armoured FIRE SURVIVAL cable with (EPR) Ethylene Propylene rubber / XLPE insulation as per BS 7846:2009 & IEC-60502:2004 Part-1 (Armoured), Retain circuit integrity as per BS 6387 C.W.Z (armoured), BS-8491:2008, BS 8434-2: 2009 (armoured), (Resistance to fire at 950º C for 3 hours), as per specifications. Cost of termination glands and GI earthing (flats / strips / wires, as may be applicable as per electric rules : Earthing system shall comply to IS: 3043-1987.) , identification tags , clamps , and saddles.

-

-

-

... More
3C x 4 Sqmm Copper

420

371

156109.8

... More
3C x 2.5 Sqmm Copper

360

358

128901.6

... More
5.5 Control Cabling

-

-

-

... More
Copper conductor , PVC insulated,PVC sheathed armoured cable of 1.1 KV grade

-

-

-

... More
4C x 1.5 Sqmm

660

195

129076.2

... More
6C x 1.5 Sqmm

1275

265

338678.25

... More
5.6 Cable Trays and cable management systems

-

-

-

... More
P/F cable trays of perforated powder quoted MS construction (2mm thick),complete with clamps and suspension arrangement

-

-

-

... More
150mm wide

400

372

149064

... More
300 mm wide

200

616

123376

... More
450 mm wide

200

855

171054

... More
5.7 Local MCB Isolator box for

-

-

-

... More
Supplying, installation, testing and commissioning of Following isolator in weather proof, 16SWG CRCA sheet steel enclosure Powder coated

-

-

-

... More
50 amp

15

3786

56803.8

... More
32 amp

4

2777

11111.68

... More
20 amp

9

2777

25001.28

... More
PART B- Operation and Maintenance of HVAC Works (Post graduate sector 46 )

-

-

-

... More
Comprehensive Maintenance & Operation Charges Minimum 8 hours x 6 Days, for first 2 years during defect liabilty period from the date of handing over the system

-

-

-

... More
Operation & Maintenance charges for Central AC system including routine and Comprehensive maintenance with parts including consumables such as gas, oil, filters and break down maintenance of high & low side of the air conditioning plant comprising of all the machinery Including deployment of 01 No AC Mech. cum Operator & 1 No Helper in single shift of Min 8.0 hrs or As per minimum requirement by Department

-

-

-

... More
1st Year ( Operation + Free of cost Comprehensive maintenance with parts) (59757 x 12 = 717084/-)

1

717084

717084

... More
2nd Year ( Operation + Free of cost Comprehensive maintenance with parts) (59757 x 12 = 717084/- + 7% = 767280)

1

767279

767279.88

... More
Comprehensive Maintenance & Operation Charges (Min.8 hrs x 6 days) after 2 years defect liabilty period from the date of handing over the system

-

-

-

... More
Operation & Maintenance charges for Central AC system including routine and Comprehensive maintenance with parts including consumables such as gas, oil, filters and break down maintenance of high & low side of the air conditioning plant comprising of all the machinery Including deployment of 01 No AC Technician in single shift of Min 8.0 hrs or As per minimum requirement by Department

-

-

-

... More
3rd Year ( Operation + 1 % of the capital cost for Comprehensive maintenance with parts) ( 767280+ 7% = 820990) + (1% of Capital Cost i.e. Rs. 1,58,56,375/- = 158563) (820990+158563= 979553/-)

1

979553

979553

... More
4th Year 7 % Increase Rs. 9,79,624 = Total Rs. 10,48,122/-

1

1048121

1048121.71

... More
5th Year 7 % Increase Rs. 10,48,122 = Total Rs. 11,21,490/-

1

1121490

1121490.23

... More
PART B- Operation and Maintenance of HVAC Works (Govt College girls sector 11)

-

-

-

... More
Comprehensive Maintenance & Operation Charges Minimum 8 hours x 6 Days, for first 2 years during defect liabilty period from the date of handing over the system

-

-

-

... More
Operation & Maintenance charges for Central AC system including routine and Comprehensive maintenance with parts including consumables such as gas, oil, filters and break down maintenance of high & low side of the air conditioning plant comprising of all the machinery Including deployment of 01 No AC Mech. cum Operator & 1 No Helper in single shift of Min 8.0 hrs or As per minimum requirement by Department

-

-

-

... More
1st Year ( Operation + Free of cost Comprehensive maintenance with parts) (59757 x 12 = 717084/-)

1

717084

717084

... More
2nd Year ( Operation + Free of cost Comprehensive maintenance with parts) (59757 x 12 = 717084/- + 7% = 767280)

1

767279

767279.88

... More
Comprehensive Maintenance & Operation Charges (Min.8 hrs x 6 days) after 2 years defect liabilty period from the date of handing over the system

-

-

-

... More
Operation & Maintenance charges for Central AC system including routine and Comprehensive maintenance with parts including consumables such as gas, oil, filters and break down maintenance of high & low side of the air conditioning plant comprising of all the machinery Including deployment of 01 No AC Technician in single shift of Min 8.0 hrs or As per minimum requirement by Department

-

-

-

... More
3rd Year ( Operation + 1 % of the capital cost for Comprehensive maintenance with parts) ( 767280+ 7% = 820990) + (1% of Capital Cost i.e. Rs. 8592728/- = 86487) (820990+85927= 906917/-)

1

906917

906917

... More
4th Year 7 % Increase Rs. 906917 = Total Rs.9,70,401/-

1

970401

970401

... More
5th Year 7 % Increase Rs. 9,70,401 = Total Rs.10,38,329/-

1

1038329

1038329

... More
PART B- Operation and Maintenance of HVAC Works (Govt College Boys)

-

-

-

... More
Comprehensive Maintenance & Operation Charges Minimum 8 hours x 6 Days, for first 2 years during defect liabilty period from the date of handing over the system

-

-

-

... More
Operation & Maintenance charges for Central AC system including routine and Comprehensive maintenance with parts including consumables such as gas, oil, filters and break down maintenance of high & low side of the air conditioning plant comprising of all the machinery Including deployment of 01 No AC Mech. cum Operator & 1 No Helper in single shift of Min 8.0 hrs or As per minimum requirement by Department

-

-

-

... More
1st Year ( Operation + Free of cost Comprehensive maintenance with parts) (59757 x 12 = 717084/-)

1

717084

717084

... More
2nd Year ( Operation + Free of cost Comprehensive maintenance with parts) (59757 x 12 = 717084/- + 7% = 767280)

1

767279

767279.88

... More
Comprehensive Maintenance & Operation Charges (Min.8 hrs x 6 days) after 2 years defect liabilty period from the date of handing over the system

-

-

-

... More
Operation & Maintenance charges for Central AC system including routine and Comprehensive maintenance with parts including consumables such as gas, oil, filters and break down maintenance of high & low side of the air conditioning plant comprising of all the machinery Including deployment of 01 No AC Technician in single shift of Min 8.0 hrs or As per minimum requirement by Department

-

-

-

... More
3rd Year ( Operation + 1 % of the capital cost for Comprehensive maintenance with parts) ( 767280+ 7% = 820990) + (1% of Capital Cost i.e. Rs. 8098303/- = 80983) (820990+80983= 901973/-)

1

901973

901973

... More
4th Year 7 % Increase Rs. 901973 = Total Rs.965111/-

1

965111

965111.11

... More
5th Year 7 % Increase Rs. 965111 = Total Rs. 1032669/-

1

1032668

1032668.89

... More
PART B- Operation and Maintenance of HVAC Works (Govt. College Home science sector 10)

-

-

-

... More
Comprehensive Maintenance & Operation Charges Minimum 8 hours x 6 Days, for first 2 years during defect liabilty period from the date of handing over the system

-

-

-

... More
Operation & Maintenance charges for Central AC system including routine and Comprehensive maintenance with parts including consumables such as gas, oil, filters and break down maintenance of high & low side of the air conditioning plant comprising of all the machinery Including deployment of 01 No AC Mech. cum Operator & 1 No Helper in single shift of Min 8.0 hrs or As per minimum requirement by Department

-

-

-

... More
1st Year ( Operation + Free of cost Comprehensive maintenance with parts) (59757 x 12 = 717084/-)

1

717084

717084

... More
2nd Year ( Operation + Free of cost Comprehensive maintenance with parts) (59757 x 12 = 717084/- + 7% = 767280)

1

767279

767279.88

... More
Comprehensive Maintenance & Operation Charges (Min.8 hrs x 6 days) after 2 years defect liabilty period from the date of handing over the system

-

-

-

... More
Operation & Maintenance charges for Central AC system including routine and Comprehensive maintenance with parts including consumables such as gas, oil, filters and break down maintenance of high & low side of the air conditioning plant comprising of all the machinery Including deployment of 01 No AC Technician in single shift of Min 8.0 hrs or As per minimum requirement by Department

-

-

-

... More
3rd Year ( Operation + 1 % of the capital cost for Comprehensive maintenance with parts) ( 767280+ 7% = 820990) + (1% of Capital Cost i.e. Rs. 1,11,00,070/- = 1,11,000) (820990 + 111000 = 931990/-)

1

931990

931990

... More
4th Year 7 % Increase Rs. 931990 = Total Rs.9,97,229/-

1

997229

997229.3

... More
5th Year 7 % Increase Rs. 997229 = Total Rs. 10,67,035/-

1

1067035

1067035.35

... More
FIRE FIGHTING SYSTEM

-

-

-

... More
1. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1 civil)

-

-

-

... More
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). (DSR 4.1.3)

8

7665

61326.24

... More
2. Brick work with common F.P.S moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 4 coarse sand) : (DSR 6.1 Civil)

-

-

-

... More
Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1)

32

7171

229492.48

... More
3. Structural Steel work in Single Section fixed with or without connecting plates including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete (DSR 10.1 Civil)

7614

114

869366.52

... More
4. 12 mm cement plaster of mix : (DSR 13.1 civil)

-

-

-

... More
1:4 (1 cement: 4 fine sand) (DSR 13.1)

264

337

89147.52

... More
5. Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. (Exposed on wall) (DSR 18.10)

-

-

-

... More
32 mm dia. nominal bore : DSR 18.10.4

160

648

103838.4

... More
6. Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : DSR 18.46

-

-

-

... More
32 mm nominal bore : DSR 18.46.4

16

475

7613.6

... More
7. Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17)

-

-

-

... More
32 mm nominal bore (DSR 18.17.2)

16

670

10735.68

... More
8.Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR 18.48)

65000

10

695500

... More
9. Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc with charcoal/coke and salt as required. (DSR 5.4)

4

7808

31232.96

... More
10. Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connection etc as required. (DSR 5.15)

80

254

20398.4

... More
11. Supplying, Installation, testing , and commissioning of Electric Driven Terrace Pump suitable for automatic operation and consisting of following : complete in all respect as required . (Terrace Pump)

-

-

-

... More
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS :1520

-

-

-

... More
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with class-F insulation, conforming to IS-325

-

-

-

... More
MS fabricated common base plate, coupling, coupling guard, foundation bolts etc, as required.

-

-

-

... More
Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
900 lpm at 35m Head (DSR 18.4.1)

8

106442

851541.2

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc and fixing the pipe on the wall/ celing with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as reuired : (DSR 18.7)

-

-

-

... More
150 mm dia (DSR 18.7.8)

156

3734

582633.48

... More
25mm dia (DSR 18.7.1)

21

777

16327.08

... More
50mm dia (DSR 18.7.4)

32

1338

42836.48

... More
80mm dia (DSR 18.7.6)

48

1969

94551.36

... More
100mm dia. (DSR 18.7.7)

388

2669

1035948.36

... More
150mm dia. (DSR 18.7.8)

90

3734

336134.7

... More
200mm dia (wall thickness 6.3mm) (DSR 18.7.9)

12

5708

68505.96

... More
13. Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : (DSR 18.11)

-

-

-

... More
200mm dia (DSR 18.11.7)

2

15891

31782.62

... More
150mm dia. (DSR 18.11.6)

5

9363

46816

... More
100 mm dia (DSR 18.11.5)

29

6967

202043.29

... More
80 mm dia (DSR 18.11.4)

12

5206

62474.28

... More
50 mm (DSR 18.11.2)

8

3954

31634.24

... More
14. Providing, installation, testing and commissioning of non-return valve of Following size conforming to IS : 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : (DSR 18.14)

-

-

-

... More
200mm dia (DSR 18.14.8)

1

30599

30599.69

... More
150mm dia. (DSR 18.14.7)

2

18586

37172.74

... More
100 mm dia (DSR 18.14.5)

20

11547

230945

... More
15. Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : (DSR 18.9)

-

-

-

... More
Single headed Gunmetal (DSR 18.9.1)

22

7990

175781.54

... More
16. Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. IS 636 (type-A) marked as required (DSR 18.16)

-

-

-

... More
Gun metal (DSR 18.16.1)

36

5436

195699.24

... More
17.Supplying and fixing first-aid Hose reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. (DSR 8.17)

-

-

-

... More
20mm nominal internal dia water hose thermoplastic ( textile reinforced) type-2 as per IS : 12585

-

-

-

... More
20mm nominal internal dia gun metal globe valve & nozzle Drum and brackets for fixing the equipmets on wall.

-

-

-

... More
Connections from riser with 25 mm dia stop gun metal valve & M.S pipe and socket.

-

-

-

... More
30m (DR 18.17.1)

18

9065

163176.66

... More
18. Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 marked, suitable for instantaneous connection to interconnect hose pipe coupling as required: (DSR 18.18)

-

-

-

... More
Gun metal (DSR 18.18.1)

14

2524

35346.08

... More
19. Supplying and fixing of fire brigade connection of cast iron body with gun metal male instanteous inlet coupling complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: (DSR 18.19)

-

-

-

... More
2 way-100 mm dia M.S pipe (DSR 18.19.1)

3

7045

21136.17

... More
4 way-150 mm dia M.S pipe (DSR 18.19.2)

1

14602

14602.83

... More
20. HOSE CABINET FOR 15 MTR. LONG HOSE REEL PIPE & BRANCH PIPE ETC.

-

-

-

... More
Supplying and fixing weather proof M.S cabinet size 600 mm x 600 mm x 450mm deep fabricated from 1.6mm thick M.S. sheets and M.S angle 40mm x40mm x6mm complete with glass, locking arrangements. (NS)

14

4843

67810.26

... More
21. 4kg, ABC FIRE EXTINGUISHER

-

-

-

... More
Providing & fixing of ISI marked (IS:15638) portable fire extinguisher, ABC (gas pressure) type capacity 4kg with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets as required (NS)

19

3005

57106.4

... More
22. Cost of 3nos set of fire buckets of 24 gauge galvanized steel sheet, standard 9 liter capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters "Fire " in black and gold (NS)

13

3649

47446.36

... More
23 Providing & fixing of Fire Extinguisher 4.5 kg carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, (NS)

19

9693

184167.57

... More
24. Supplying, laying, testing and commissioning of MS made cubicle panel made out of 1.6mm CRCA sheet powder coated with siemens color. The panel is design for wall mounting type with cable incoming and out goings from bottom. All the switchgear are from L&T /Schneider/Eaton Make MCB TP 32A, Contractor MNX-12A., Over load relay 4.5-7 5A, ON/OOF indication, STOP/START Push Button, Auto/Manual Switch, Terminal STRIP, MBC 1 POLE 6 Amp, Aux. Cont., SDS Timer, SPPR, Enclosure & accessories fabrication in 1.6mm. CRCA Sheet powder coating in Siemens Gray Shede, 75X40MM. Channel Base Frame, Cable Entry will be Top & Bottom Suitable for Cable Lock, Rubber Gasket, hardware etc. Wiring & Accessories Power & Control wiring will be (ISI 1100V) flamo smoke FRLS PVC Singte Core Copper Wire Copper Lugs, PVC Steeve, Ferruels Numbers, Hardware & Lbour etc. including Starter suitable for 7.5 Hp mortor for 2 pump which can be operate simultaneously.

3

45434

136302.72

... More
25. Supplying and laying of XLPE insulated, PVC sheathed aluminium conductor 1.1 KV grade armoured I.S.I marked cable of makes given in the list of approved makes of following sizes laid on surface including cable terminations, galvanised cable tray of thickness as specified, brass compression Glands, aluminium lugs suitably clamped as specified and as required.

-

-

-

... More
3.5 Core x 25 sq. mm.

200

533

106640

... More
26. Providing & fixing Photo illumecent Exit signages of Size 12" x 6".

9

1264

11384.1

... More
27. Supplying and fixing air vessel made of 250mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25mm dia gum metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. (DSR 18.20 ele)

9

19064

171584.82

... More
28. Providing & fixing 100 mm dia Bourden type, Pressure Gauge including brass isolation valve and siphon pipe (NS)

8

973

7791.76

... More
29. Providing and fixing of cover for all terrace pumps made up of corrugated PVC fibre sheet with 35 x 35 x 5 MS angel frame with openable door having lockable facility and painting the MS angel with 1 coat of red oxide primer and 2 coats of black enamel paint complete in all respects as shown in the drawings (NS)

8

4917

39340.32

... More
30. Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required (DSR 18.22 ele)

8

1615

12924.56

... More
31. Supplying and installing following size of preforated painted with powder coating M.S cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with M.S suspendered including bolts & nuts painting suspenders etc as required. (DSR 4.1 ele)

-

-

-

... More
100 x 50 x 1.6mm (DSR 4.1.1)

120

567

68091.6

... More
32. Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (DSR 18.1)

-

-

-

... More
(a)      Horizontal type, multistage, centrifugal, End suction pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.

-

-

-

... More
(b)   Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.

-

-

-

... More
(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.

-

-

-

... More
(d) Suitable cement concrete foundation duly plastered

-

-

-

... More
2280 lpm at 70 m Head (DSR 18.1.5)

1

385671

385671.88

... More
33. SSupplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) (DSR 18.2)

-

-

-

... More
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS :1520

-

-

-

... More
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts electric starting equipment, diesel tank, exhaust pipe entended upto 10m outside pump house duly insulated with 50mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.

-

-

-

... More
M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc as required

-

-

-

... More
Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
2280 lpm at 70 m Head

1

639607

639607.92

... More
34. a) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with class F insulation, conforming to IS : 325. d) M.S fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required e) Suitable cement concrete foundation duly plastered and with anti vibration pads. (DSR 18.3)

-

-

-

... More
180 lpm at 70 m Head (DSR 18.3.2)

1

107952

107952.68

... More
35. Fabrication, supply, Insallation testing & commissioning of Electricalcontrol panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgear and accessories, mountings and internal wiring earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac supplying with enclosure protection class IP 42 as required : (DSR 18.5)

-

-

-

... More
INCOMING (DSR 18.5.1)

-

-

-

... More
250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etcLED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A

-

-

-

... More
OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)

-

-

-

... More
Main Fire Pump

-

-

-

... More
125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.

-

-

-

... More
Jockey Pump

-

-

-

... More
63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, Auto/ manual/ OFF operation.

-

-

-

... More
DIESEL ENGINE CONTROL

-

-

-

... More
Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, supplying, Installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace Pump in sequence as per specification consisting of relays, timers. Sensors, annuciation window for fault indication,complete as per specification,

1

256787

256787.85

... More
36. Supplying & laying of following 1100 volt grade XLPE insulated PVC sheathed aluminium/ conductor armoured cables as per specification in existing trenches, cable trays, ducts, clamped to wall with suitable clamps including providing and fixing of all fixing accessories, connecting, testing and commissioning. (NS)

-

-

-

... More
3.5 core 120 sq. mm Aluminium conductor

150

1652

247822.5

... More
3.5 core 70 sq. mm Aluminium conductor

80

1087

87024.8

... More
4 core 16 sq. mm. Aluminium conductor

50

448

22427.5

... More
37. Supply, installation, testing & commissioning of copper Ar. control cable of following size (NS)

-

-

-

... More
6C x 1.5 Sqmm

20

263

5273.6

... More
2C x 1.5 Sqmm

60

144

8698.8

... More
38. Supplying and installing following size of preforated painted with powder coating M.S cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with M.S suspendered including bolts & nuts painting suspenders etc as required. (DSR 4.1 ele)

-

-

-

... More
100 mm width X 50mm depth X 1.6mm thickness (DR 4.1.1)

80

567

45394.4

... More
150 mm width X 50mm depth X 1.6mm thickness (DSR 4.1.2)

60

631

37870.8

... More
UGR & Pump

-

-

-

... More
39. Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (DSR 2.6)

-

-

-

... More
All kind of Soil ( DSR 2.6.1)

173.46

172

29958.28

... More
40. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. ( DSR 2.25)

58.48

190

11152.72

... More
41. Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. ( DSR 2.26)

-

-

-

... More
All kind of Soil ( DSR 2.26.1)

52.49

123

6476.22

... More
42. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1)

-

-

-

... More
1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.10)

8.29

6342

52580.15

... More
43. Centering and shuttering including strutting, propping etc. and removal of form for ( DSR 5.9)

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete ( DSR 5.9.1)

5.84

381

2228.31

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. ( DSR 5.9.2)

178.89

819

146645.08

... More
Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3)

86.8

902

78311.83

... More
44. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (DSR 5.22)

-

-

-

... More
Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6)

9286.2

104

974493.83

... More
45. Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR 8.31)

115.24

1233

142173.89

... More
46. Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR 11.37)

29.25

1066

31208

... More
47. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1)

-

-

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2)

19.4

6939

134629.79

... More
48. Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate I retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:

-

-

-

... More
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
All works upto plinth level (DSR 5.33.1)

-

-

-

... More
Concrete of M30 grade with minimum cement content of 350 kg /cum (DSR 5.33.1.2)

67.84

9395

637356.8

... More
49. 12 mm cement plaster of mix.

-

-

-

... More
1: 6 (1 cement : 6 fine sand) (DSR ref. 13.1.2)

96

368

35374.08

... More
50. 15mm cement plaster on the rough side of single or half brick wall of mix.

-

-

-

... More
1: 6 (1 cement : 6 fine sand) (DSR ref. 13.2.2)

96

425

40838.4

... More
51. 6mm cement plaster of mix

-

-

-

... More
1: 3(1 cement : 3 fine sand) (DSR ref. 13.16.1)

56

292

16371.04

... More
52. Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.(DSR ref. 13.80)

248

151

37656.32

... More
53. Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.

-

-

-

... More
Two coats (DSR ref. 13.82.2)

248

133

33167.52

... More
ELECTRICAL WORK

-

-

-

... More
SCHEDULE NO. 1

-

-

-

... More
(ELECTRICAL INSTALLATION WORK)

-

-

-

... More
1) DSR item No.1.10:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group C

153

1533

234549

... More
2) DSR item No.1.55:- Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group C

71

897

63687

... More
3) DSR item No.1.11:- Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular switch, suitable M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

6

1632

9792

... More
4) DSR item No.1.21:- Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required :

-

-

-

... More
a) 20 mm.

1000

134

134000

... More
b) 25 mm.

3150

152

478800

... More
5) DSR item No.1.17:- Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
a) 2 x 1.5 sq. mm wire (for Dimmer/Dali Ballast)

400

73

29200

... More
b) 3 x 1.5 sq. mm (For Light Plug & Switch Board)

1950

99

193050

... More
c) 3 x 2.5 sq. mm (For Double Light Plug & Power Point)

1945

143

278135

... More
d) 3 x 4 sq. mm (For Industrial Socket - 1 Phase)

340

215

73100

... More
6) DSR item No.1.14:- Wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
a) 2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire. ( For lighting to console Panel )

3750

243

911250

... More
b) 4 X 6 sq.mm + 2 X 6 sq.mm earth wire (For 3 Phase Industrial Socket)

420

788

330960

... More
c) 4 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire (For various TPN BDBs)

450

1050

472500

... More
d) 4 x 16 sq.mm. + 2 x 6 sq.mm. Earth wire (For various TPN BDBs)

220

1426

313720

... More
7) DSR item No.1.31:- Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps. modular switch, connection etc. as required.

107

498

53286

... More
8) DSR item No.1.56:- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non-residential buildings).

18

706

12708

... More
9) DSR item No.1.32:-

75

612

45900

... More
Supply and fixing of suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps. modular switch, connection etc. as required.

-

-

-

... More
10) DSR item No.2.18:- Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 poles and earth metal enclosed plug top along with 20 amps. "C" curve, SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required.

19

1694

32186

... More
11) DSR item No.2.20:- Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

12

4292

51504

... More
12) DSR item No.1.26:- Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

40

42

1680

... More
13) DSR item No.2.3:- Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
a) 12 way , Double door (For Lift )

1

2419

2419

... More
14) DSR item No.2.5:- Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required.

-

-

-

... More
a) 4 way (4 + 12), Double door

4

7850

31400

... More
b) 8 way (4 + 24), Double door

20

10622

212440

... More
15) DSR item No. 2.10:- Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
a) Single pole

447

268

119796

... More
b) Double pole

1

686

686

... More
c) Triple Pole & Neutral

8

1283

10264

... More
16) DSR item No.2.14:- Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
a) 40 amps.

4

2761

11044

... More
b) 63 amps.

4

2844

11376

... More
17) DSR item No.2.11:- Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required.

8

14

112

... More
18) DSR item No. 1.27:- Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required

-

-

-

... More
1 or 2 Module (75 mm x 75 mm)

58

311

18038

... More
19) DSR item No.1.24:-

-

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required

-

-

-

... More
Telephone Socket outlet

18

155

2790

... More
TV Antenna socket outlet

14

155

2170

... More
20) DSR item No.1.18:- Supply and drawing following pair, 0.5 sq. mm. FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
2 Pair

800

40

32000

... More
21) DSR item No.1.19:- Supply and drawing co-axial TV cable RG-6 grade, 0.7 mm. Solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

400

49

19600

... More
22) DSR item No.1.53:- Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.

-

-

-

... More
1 run of cable

4300

60

258000

... More
23) Supply & erection MCB 4 pole 63 Amp 415 Volt 10KA Breaking Capacity ‘C’ Curve without enclosure. The job includes the labour charges and other petty material required to complete the job. The MCB should be of Lauritz Knudsen (Exora)/ Hager (H3)/ Siemens (Betagard)/ ABB (SB200M)/ Schnieder (Acti-9)/ Legrand (DX3) only.

12

1960

23520

... More
24) Supply & erection MCB TP 63 Amp 415 Volt 10KA Breaking Capacity ‘C’ curve without enclosure. The job includes the labour charges and other petty material required to complete the job. The MCB should be of Lauritz Knudsen (Exora)/ Hager (H3)/ Siemens (Betagard)/ ABB (SB200M)/ Schnieder (Acti-9)/ Legrand (DX3) only.

16

1570

25120

... More
25) Supply & fixing of RJ 45 SOCKET with Shutter for CAT 6 LAN cable (one module) including making connection as required completing the job to the entire satisfaction of EIC. The RJ 45 Socket should be of Schneider (Zencelo)/ Legrand (Arteor)/ Norisys (Square Series)/ MK (Elements)/ North-West (Platia)/ Crabtree (Murano)/ Lauritz Knudsen (Englaze) makes only.

26

595

15470

... More
26) Supply and installation of an 8-module (2x4) Pop-Up Type Flush-Mounting Box for the floor with a metal flush mounting box, matte aluminum finish, and installation kit. The box should be suitable for mounting 2 Nos. 16 Amp modular multi-sockets, 2 Nos. 16 Amp modular switches, and 2 Nos. RJ-45 data points. The job includes the cost of modular accessories and all other necessary materials to complete the work to the satisfaction of the Engineer-in-Charge. Approved makes: Legrand/ Honeywell only.

16

9600

153600

... More
27) Supply, installation, testing, and commissioning of a Linear Slim LED Fitting suitable for suspended down-type installation, with housing made of high-quality extruded aluminum alloy, including die-cast aluminum end caps, complete in all respects as specified below. The fitting should be of Bajaj/ Philips/ Wipro/ Jaquar/ Havells/ Crompton/ Lighting Technologies/ Trilux/ Panasonic make only. The job includes the cost of carriage and erection, including cutting of ceiling gypsum/ wooden boards, making connections, and testing and commissioning the fitting to the complete satisfaction of the Engineer in Charge

-

-

-

... More
Specification of LED fittings:

-

-

-

... More
Wattage of LED fittings As per following parameters

-

-

-

... More
Total lumens of the LED fittings Minimum 3300 lumen

-

-

-

... More
Body of fittings CRCA steel sheet with opal acrylic diffuser/ Extruded al. Housing CRCA front frame opal diffuser/ CRCA power coated housing with high efficiency translucent diffuser.

-

-

-

... More
Operating voltage 140 V to 270 V, AC supply or better.

-

-

-

... More
Input frequency 50 Hz + 1 Hz

-

-

-

... More
Power factor Minimum 0.95

-

-

-

... More
Luminaire efficacy Minimum 110 lm/w

-

-

-

... More
Colour rendering index CRI shall be 80 (minimum)

-

-

-

... More
Working/ operating temperature 00 to + 450c or better

-

-

-

... More
Colour temperature As required at site as per the Lighting Design

-

-

-

... More
Electronic Driver  

-

-

-

... More
Drive current (LED)As per OEM.

-

-

-

... More
Operating voltage 140 V to 270 V AC supply or better

-

-

-

... More
Type of driver Constant current output driver

-

-

-

... More
THD Less than 10%

-

-

-

... More
Surge Protection 2.5 KV minimum

-

-

-

... More
Efficiency Driver85%

-

-

-

... More
Protection Shall have under voltage and over voltage protection.

-

-

-

... More
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.

-

-

-

... More
Fixture Should comply with LM 79 test from NABL/UL lab.

-

-

-

... More
Connection Loop in loop out option inbuilt accessories as required for continuous linear connection

-

-

-

... More
LED Type/ Make/ ModelPower CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hour’s @70% lumen maintenance with LM 80 test report from the manufacturer.

-

-

-

... More
Life of LED 50000 burning Hour’s at 70% Lumen maintenance

151

6000

906000

... More
28) Supply & Erection of LED Down Lighter (Recess Type), complete in all respects. The Down Lighter should be of Bajaj/ Phillips/ Wipro/ Jaquar/ Havells/ Crompton/ Lighting Technologies/ Trilux/ Panasonic make only. The job includes the cost of carriage and erection, including the cutting of ceiling gypsum/ wooden boards, making connections, and testing and commissioning of the fitting to the complete satisfaction of the Engineer in Charge.

-

-

-

... More
Specification of LED fittings:

-

-

-

... More
Wattage of LED fittings As per following parameters

-

-

-

... More
Total lumens of the LED fittings Minimum 1200 lumen

-

-

-

... More
Body of fittings CRCA steel sheet with opal acrylic diffuser/ Extruded al. Housing CRCA front frame opal diffuser/ CRCA power coated housing with high efficiency translucent diffuser.

-

-

-

... More
Operating voltage 140 V to 270 V, AC supply or better.

-

-

-

... More
Input frequency 50 Hz + 1 Hz

-

-

-

... More
Power factor Minimum 0.95

-

-

-

... More
Luminaire efficacy Minimum 100 lm/w

-

-

-

... More
Colour rendering index CRI shall be 80 (minimum)

-

-

-

... More
Working/ operating temperature 00 to + 450c or better

-

-

-

... More
Colour temperature As required at site as per the Lighting Design

-

-

-

... More
Electronic Driver  

-

-

-

... More
Drive current (LED)As per OEM.

-

-

-

... More
Operating voltage 140 V to 270 V AC supply or better

-

-

-

... More
Type of driver Constant current output driver

-

-

-

... More
THD Less than 10%

-

-

-

... More
Surge Protection 2.5 KV minimum

-

-

-

... More
Efficiency Driver85%

-

-

-

... More
Protection Shall have under voltage and over voltage protection.

-

-

-

... More
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.

-

-

-

... More
Fixture Should comply with LM 79 test from NABL/UL lab.

-

-

-

... More
LED Type/ Make/ Model Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hour’s @70% lumen maintenance with LM 80 test report from the manufacturer.

-

-

-

... More
Life of LED50000 burning hours at 70% lumen maintenance

92

790

72680

... More
29) Supply and installation of 20-watt LED Track Light Fitting on the existing track. The LED fixture should have a minimum efficacy of 100 Lm/watt and a colour temperature as per site requirements/ lighting design. The job includes testing, commissioning, and connecting with 3x1.5 sq. mm copper wire from the adjacent light point, as well as all petty materials and labour required to complete the work to the satisfaction of the Engineer-in-Charge. The fixture should be Bajaj/ Phillips/ Wipro/ Jaquar/ Havells/ Crompton/ Lighting Technologies/ Trilux/ Panasonic make only. The sample of the LED track light fixture and track for installation must be approved by the Engineer-in-Charge prior to site installation.

72

3420

246240

... More
Supply and installation of single-phase 1-Meter Track for existing LED track light fittings. Includes all petty materials necessary to complete the job to the satisfaction of the Engineer-in-Charge. The track should be of the same make as the LED track light fittings.

3

1065

3195

... More
Supply and installation of single-phase 2-Meter Track for existing LED track light fittings. Includes all petty materials necessary to complete the job to the satisfaction of the Engineer-in-Charge. The track should be of the same make as the LED track light fittings

16

1890

30240

... More
30) S/E of 2’x2’ LED fitting Recess Type with integral/ non integral driver to be installed on existing false ceiling with the help of steel chain, steel rawl plug & screws etc. The fitting should be Bajaj/ Phillips/ Wipro/ Jaquar/ Havells/ Crompton/ Lighting Technologies/ Trilux/ Panasonic make only. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of EIC.

-

-

-

... More
Specification of LED fittings

-

-

-

... More
Wattage of LED fittings As per following parameter.

-

-

-

... More
Total lumens of the LED fittings Minimum 3960 lumen

-

-

-

... More
Body of fittings CRCA steel sheet with opal acrylic diffuser/ Extruded Aluminum Housing CRCA front frame opal diffuser/ CRCA power coated housing with high efficiency translucent diffuser.

-

-

-

... More
Operating voltage 140 V to 270 V, AC supply or better.

-

-

-

... More
Input frequency 50 Hz + 1 Hz

-

-

-

... More
Power factor Minimum 0.90

-

-

-

... More
Luminaire efficacy Minimum 120 lm/w

-

-

-

... More
Colour rendering index CRI shall be 80 (minimum)

-

-

-

... More
Working/ operating temperature 00 to + 450c or better

-

-

-

... More
Colour temperature 57000K +10%

-

-

-

... More
Electronic Driver  

-

-

-

... More
Drive current (LED)As per OEM.

-

-

-

... More
Operating voltage 140 V to 270 V AC supply or better

-

-

-

... More
Type of driver Constant current output driver

-

-

-

... More
THD Less than 10%

-

-

-

... More
Surge Protection 2.5 KV minimum

-

-

-

... More
Efficiency Driver80%

-

-

-

... More
Protection Shall have under voltage and over voltage protection.

-

-

-

... More
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.

-

-

-

... More
Fixture Should comply with LM 79 test from NABL/UL.

-

-

-

... More
LED Type/ Make/ Model Power Cree/ Philips Lumiled/ Osram/ Nichia with life more than 50,000 burning hour’s @70% lumen maintenance with LM 80 test report from the manufacturer.

-

-

-

... More
Life of luminaire 50000 burning hours at @ 70% lumen maintenance

59

3560

210040

... More
31) Supply installation testing commissioning of DALI Dimmable Circular Recess Down Light Fixture to be recess in false ceiling. The fitting should be Bajaj/ Phillips/ Wipro/ Jaquar/ Havells/ Crompton/ Trilux/ Lighting Technologies/ Panasonic make only. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point. The job includes all labour and petty material required to install the fitting to the entire satisfaction of the EIC of work. The LED fittings should be as per following design criteria.

-

-

-

... More
Technical Specifications of LED Fixture : Circular Recess Down Light Fixture DALI Dimmable

-

-

-

... More
Wattage of LED fittings: As per following parameters

-

-

-

... More
Total lumens output of the LED fittings: Minimum 2400 Lumen or better

-

-

-

... More
Housing: Die cast aluminium

-

-

-

... More
Diffuser: High efficiency translucent PMMA Diffuser

-

-

-

... More
Operating voltage: 140 - 270Volt, AC, 50Hz ± 1%

-

-

-

... More
Power factor: 0.95

-

-

-

... More
Luminaries efficacy: Minimum 120 Lm/Watt or Higher

-

-

-

... More
Colour Rendering Index: CRI shall be 80

-

-

-

... More
Working/ operating temperature: 0℃ to 45℃ or better

-

-

-

... More
Colour Temperature: As required at site as per the Lighting Design

-

-

-

... More
Electronic Driver

-

-

-

... More
Drive current (LED): As per OEM

-

-

-

... More
Type of Driver: Constant current, Constant Voltage output driver

-

-

-

... More
THD: 10%

-

-

-

... More
Surge Protection: 2.5 KV Minimum

-

-

-

... More
Driver Efficiency: 85%

-

-

-

... More
Protection: Over & Under Voltage protection

-

-

-

... More
Guarantee of LED fixture including driver: 2 Years from the date of Installation

-

-

-

... More
Fixture: Should comply LM 79 test from NABL or UL accredited Lab

-

-

-

... More
LED Make: Power CREE, OSRAM, NICHIA, Philips LumiLED.

-

-

-

... More
Type of LED: 50,000 burning hours @ 70% lumen maintenance complying with LM 80 test report

-

-

-

... More
Life of LED: 50,000 burning hours at 70% lumen maintenance

395

5480

2164600

... More
32) Supply, installation, testing, and commissioning of a 6-Watt LED Step Light (recess type) with aluminum die-cast housing in powder-coated grey color and CCT 3000K, complete with an electronic driver. The job includes testing and commissioning to the satisfaction of the Engineer-in-Charge. The fitting should be of Bajaj/ Phillips/ Wipro/ Jaquar/ Havells/ Crompton/ Lighting Technologies/ Trilux/ Panasonic make only. The sample of the fixture must be approved by the Engineer-in-Charge prior to site installation.

320

1465

468800

... More
33) S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA / PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen and the driver of the fitting should be workable on 140-260 Volt. The colour temperature of LED should be minimum 5000 degree Kelvin. The LED Bulk Head fitting should be of Bajaj/ Phillips/ Wipro/ Jaquar/ Havells/ Crompton/ Lighting Technologies/ Trilux/ Panasonic make only. The fitting should be of IP-65/66. The LED should have a life of 50000 burning Hours. The fitting should have THD15% and power factor 0.9 or above. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer in Charge.

10

1130

11300

... More
34) DSR item No. 19.1:- Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

23

2853

65619

... More
35) Supply & Erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC.

-

-

-

... More
Size 12 inches (300mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP)/ Orient (Industrial Heavy Duty)/ Usha (Turbo HDEF)/ Crompton (EXHD300-6-1)/ Bajaj (Supreme Plus) make only.

24

4245

101880

... More
36) Supplying, Installation, Testing & Commissioning of Modular, Sectionalized (Form-4B Construction) Low Voltage Panel suitable for 415 V, 3 Phase, 4 wire 50 Hz AC supply system as per standard IEC 61439 Part-1 & Part-2 as Totally Type Tested Assembly and of suitable size fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers & doors of 1.6mm thick sheet, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process before painting for surface treatment and powder coated, with suitable high conductivity Aluminium Bus Bar extensible type, DMC/SMC bus bar supports, bottom base channel of MS section not less than 100mm x 50mm x 5 mm thick, fabrication shall be done in transportable sections, entire LENGTH panel shall have a common copper earth bar of suitable size at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Aluminium bus bars and control wiring with 2.5 Sq.mm. PVC insulated copper FR conductor S/C cable for voltage & Current respectively. The LT Panel shall be dust and vermin proof with degree of protection IP42, free standing type mounted on base channel. The job includes all material cost (ACB, MCCBs &other Accessories) labour, carriage of panel to the site, testing and commissioning as required to complete the job as per drawing of the panel to the satisfaction of the Engineer in charge. The LT Panel should be tested for internal arc withstand capacity of 65KA for 0.3 second as per IEC-61641. The job includes making connection of the outgoing cable with lugs/thimbles duly crimped and making connection with the incoming existing O/H bus trunking or cable as per site requirement. The LT panel should have provision of following switchgear and accessories as mentioned below: -

-

-

-

... More
[Note: - The Make & model of MCCB should be of Lauritz Knudsen (D Sine)/ Schneider (Compact NSX)/ Siemens (3VA)/ ABB (T-max)/ Legrand (DPX3) make only].

-

-

-

... More
LT PANEL FOR HOME SCIENCE COLLEGE, SECTOR-10 AND POST GRADUATE COLLEGE, SECTOR-46.

-

-

-

... More
INCOMING

-

-

-

... More
630 Amps, 50KA, 4 Pole MCCB with Microprocessor Release (Ics = Icu at 415V), provided with LSIG protections :- 2 Nos.

-

-

-

... More
Intelligent Multifunction Digital Meter to read V, A, KVA, KWH,THD, PF Hz, kVARh, Vah, VARh, MD, Import/Export and RS 485 Port etc. with 3 Nos. resin cast CTs of 630/5A class 0.5 accuracy and 15 VA burden :- 2 Nos.

-

-

-

... More
Phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice as required : - 2 Set

-

-

-

... More
BUSBARS:

-

-

-

... More
TPN Aluminium bus bars (having 100% Neutral) of minimum of 800 Amp. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminium bus shall be 1 Amp/sq.mm. :-1 Set.

-

-

-

... More
AUTO TRANSFER SWITCH:

-

-

-

... More
630 Amps., Four Pole, 415 volts, 50Hz On Load AUTO TRANSFER SWITCH conforming to IS/IES 60947-3 along with Positive ON/OFF indication of S-Ds, Auxiliary Contact Kits, Castell Lock and other accessories as required at site to the satisfaction of Engineer-in-Charge. The Auto Transfer Switch should be of Lauritz Knudsen/ Schneider/ Socomec/ Siemens/ ABB/ Legrand/ Eaton make only:- 1 No.

-

-

-

... More
OUTGOING:

-

-

-

... More
400 Amps, 50KA, 4 Pole MCCB with Microprocessor Release (Ics = 100% of Icu at 415V), provided with LSIG protections: - 1 No.

-

-

-

... More
100 Amps, 36KA, 4 Pole MCCB with Thermal Magnetic Release, (Ics = 100% of Icu at 415V), provided with adjustable overload and adjustable short circuit protection :- 9 Nos.

2

482300

964600

... More
LT PANEL FOR GOVT. GIRLS COLLEGE, SECTOR-11 AND GOVT. BOYS COLLEGE, SECTOR-11

-

-

-

... More
INCOMING

-

-

-

... More
315 Amps, 50KA, 4 Pole MCCB with Microprocessor Release (Ics = 100% of Icu at 415V), provided with LSIG protections :- 2 Nos.

-

-

-

... More
Intelligent Multifunction Digital meter to read V, A, KVA, KWH,THD, PF Hz, kVARh, Vah, VARh, MD, Import/Export and RS 485 port etc. with 3 Nos. resin cast CTs of 315/5A class 0.5 accuracy and 15 VA burden :- 2 Nos.

-

-

-

... More
Phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice as required : - 2 Set

-

-

-

... More
BUSBARS:

-

-

-

... More
TPN Aluminium bus bars (having 100% Neutral) of minimum of 400 Amp. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminium bus shall be 1 Amp/sq.mm. :-1 Set.

-

-

-

... More
AUTO TRANSFER SWITCH:

-

-

-

... More
315 Amps, Four Pole, 415 volts, 50Hz On Load AUTO TRANSFER SWITCH conforming to IS/IES 60947-3 along with Positive ON/OFF indication of S-Ds, Auxiliary Contact Kits, Castell Lock and other accessories as required at site to the satisfaction of Engineer-in-Charge. The Auto Transfer Switch should be of Lauritz Knudsen/ Schneider/ Socomec/ Siemens/ ABB/ Legrand/ Eaton make only:- 1 No.

-

-

-

... More
OUTGOING:

-

-

-

... More
250 Amps, 36KA, 4 Pole MCCB with Thermal Magnetic Release(Ics = 100% of Icu at 415V),provided with adjustable overload and adjustable short circuit protection:- 1 No.

-

-

-

... More
100 Amps, 36KA, 4 Pole MCCB with Thermal Magnetic Release (Ics = 100% of Icu at 415V),provided with adjustable overload and adjustable short circuit protection :- 9 Nos.

2

391390

782780

... More
37) DSR Item No. 9.1:- Supplying & making of end terminations with brass compression gland and Al. lugs for following sizes of PVC insulated and PVC sheathed/ XLPE Al. conductor cable of 1.1 KV grade as required.

-

-

-

... More
3½ X 300 sq. mm (70mm)

16

1249

19984

... More
3½ X 240 sq. mm (62mm)

2

1073

2146

... More
3½ X 185 sq. mm (57mm)

2

914

1828

... More
3½ X 35 sq. mm (32mm)

8

386

3088

... More
3½ X 25 sq. mm (28mm)

16

327

5232

... More
38) Supply and laying of XLPE insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing METAL/ HUME/ DWC/ RCC pipe as required at site to the entire satisfaction of Engineer-in-Charge. The job includes labour charges of laying the cable and making connections etc. The cable should be of Polycab/ Havells/ Finolex/ R.R. Kabel/ KEI/ Universal/ RPG make only.

-

-

-

... More
Size 300 sq.mm 3.5 core.

1500

2773

4159500

... More
Size 240 sq.mm 3.5 core.

200

2280

456000

... More
Size 185 sq.mm 3.5 core.

100

1784

178400

... More
Size 35 sq.mm 3.5 core.

345

437

150765

... More
Size 25 sq.mm 3.5 core.

190

354

67260

... More
39) DSR Item No. 5.4:- Earthing with G.I. earth Plate 600mm x 600mm x 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long with charcoal or coke and salt as required.

8

7808

62464

... More
40) DSR Item No. 5.15:- Providing and fixing 25mm x 5mm GI Strip on surface or in recess for connections etc. as required.

190

255

48450

... More
41) DSR Item No. 4.1:- Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
200 mm width X 50 mm depth X 1.6 mm thickness

340

720

244800

... More
300 mm width X 50 mm depth X 1.6 mm thickness

50

812

40600

... More
42) DSR Item No. 2.21:- Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.

4

281

1124

... More
43) DSR item No. 2.22:- Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.

1

305

305

... More
44) DSR Item No. 14.14:- Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.

-

-

-

... More
250 mm dia

100

1019

101900

... More
45) DSR item No.14.15:- Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.

-

-

-

... More
120 mm dia (OD-120 mm & ID-103mm nominal)

200

259

51800

... More
46) DSR Item No. 14.16:- Supplying and laying of following size DWD HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. confirming to IS 14930, Part II Complete with fitting and cutting, jointing etc. Direct in ground (75cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
90 mm dia (OD-90 mm & ID-76mm nominal)

100

303

30300

... More
120 mm dia (OD-120 mm & ID-103mm nominal)

900

385

346500

... More
47) Supply and installation of ISI-marked Rubber Mats, 6’ x 3’ x 12 mm thick, of superior quality and make approved by the Engineer-in-Charge, to be laid in front of HT/MV panels as required at the site.

8

2325

18600

... More
48) Supply of Resuscitation Kit, including essential tools for emergency breathing and cardiac support such as a bag-mask valve, oxygen supply, instruction manual, and necessary components.

8

3195

25560

... More
49) Supply and Erection of 4 Sand Buckets, each with a 10-liter capacity, made from 24-gauge G.I. sheet. The buckets, filled with sand, shall be hung on a suitable angle iron stand, fabricated from 1¼” x 1¼” x ⅛” angle iron, with hooks for hanging the buckets in two rows. The job includes the cost of painting the buckets and stand with two coats of high-quality red paint, following a primer coat, to the full satisfaction of the Engineer-in-Charge

20

2435

48700

... More
50) Supply and erection of ISI-marked Fire Extinguisher, duly installed or hung on walls with hooks, including the cost of hooks and all materials and labor required to complete the job to the full satisfaction of the Engineer-in-Charge

-

-

-

... More
CO2 type of 9 Kg capacity fire extinguishers conforming to IS.

8

15470

123760

... More
51) Supply and erection of a medium-sized first aid box made of 16-gauge MS sheet, with dimensions of 14” x 7” x 5”, containing 6 wound dressings, 3 burn dressings, 13 grams of absorbent cotton wool, one pair of dressing scissors, one bottle of spirit of sal volatile, one tube of burn ointment (Burnol), aspirin tablets, and 1 artificial respirator.

8

1600

12800

... More
52) Supply and erection of Shock Treatment Chart written in Hindi, English, and the local language, framed in wood with glass, in compliance with the Indian Electricity Act (Safety Rules).

8

110

880

... More
Lighting Control and Automation

-

-

-

... More
53) Supply, Installation, Testing & Commissioning of Power supply 24-36Volts DC, DIN rail mounted, power supply shall produce Quite Reliable power. Power supply shall be tested against very stringent relevant power standards CE/UL/CUL listed. Ambient operating temp. 0-45 degree, operating humidity 5-95%, non-condensing, Cooling Convection, complete in all respect as required.

4

30000

120000

... More
Approved Make: - Legrand/ Lutron/ Schneider/ Philips/ ABB/ Havells/ Wipro/ Jung make only.

-

-

-

... More
54) Supply, Installation, Testing & Commissioning of Ethernet Gateway/ Controller range. The device should support the TCP/IP protocol, with static or DHCP assigned IP addressing. Serial Ports 1/2/5 x RS485/232 serial port, 1x10/100 Base T Ethernet port. In built USB port, Micro SD Card port and Supported Ethernet Protocols. The controller should be capable for remote service. TCP/ IP/ HHTP/ FTP/ Telnet/ Encryption AES-256 bit. Compliance CE/UL /cUL/ FCC. And shall be in built with Astronomical Timer Module having 365 days timer clock with tracking sunrise to sunset. Automatic daylight saving adjustment & logic function, the timer shall interface with other devices to automate tasks and events and for using as an energy management controller or simply to select scenes at pre-set times of the day or week. Complete inn all respect as required. Approved Make:- Legrand/ Lutron/ Schneider/ Philips/ ABB/ Havells/ Wipro/ Jung make only.

4

20790

83160

... More
55) Supply, Installation, Testing & Commissioning of Relay Gateway all in one with minimum 20 inputs (channel) DIN rail installation, capable of performing multiple functions including:-ON-OFF lights control dimmingControl of Shutters and curtainsControl of controlled sockets Control of fan coils with 2 and 3 points valve adjustment.The job includes the cost of all petty material and connections charges as required to complete the job in the entire satisfaction of Engineer-in-charge. Approved Make:- Legrand/ Lutron/ Schneider/ Philips/ ABB/ Havells/ Wipro/ Jung make only.

4

48000

192000

... More
56) Supply, Installation, Testing & Commissioning of 64CH DALI Ballast Dimming & Tuning Actuator, DIN-Rail Mount, with built in DALI power supply and single/double DALI bus. The unit can also support 64 DALI ballasts, and scene control. The job includes the cost of all connections charges as required to complete the job in the entire satisfaction of Engineer-in-charge. Approved Make:- Legrand/ Lutron/ Schneider/ Philips/ ABB/ Havells/ Wipro/ Jung only.

9

27495

247455

... More
57) Supply, Installation, Testing & Commissioning of Keypad 8 Button or better, Touch Screen, multiple used to control the lighting, curtain, scene, music, AC and floor heating. Built-in temperature sensor and proximity sensor. The job includes the cost of all connections charges as required to complete the job in the entire satisfaction of Engineer-in-charge. Approved Make:- Legrand/ Lutron/ Schneider/ Philips/ ABB/ Havells/ Wipro/ Jung only.

8

56760

454080

... More
SCHEDULE NO. 2

-

-

-

... More
FIRE DETECTION AND ALARM SYSTEM

-

-

-

... More
1)    Supply, Installation, Testing & Commissioning of microprocessor based multi-loop, true peer-to-peer networkable addressable fire alarm control panel with minimum 240 (Minimum) characters LCD display. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop. Each loop shall have a capacity of minimum 250 analog addressable devices. The panel should have 100% Hot redundant Fire Alarm Panel. In case, there is no inbuilt redundancy, the bidder/ firm shall have to supply additional equipment to provide this redundancy without any extra cost. Four access levels, flash EPROM, Panel should be capable to work 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 minutes in alarm condition.

-

-

-

... More
The panel shall support integration with approved make digital voice evacuation system controller capable of broadcasting evacuation messages on same peer-to-peer network and 2 ways communication fire fighters system capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC operation.

-

-

-

... More
The Panel shall have Modbus/ BACnet over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable for remote accessibility on a mobile app through cloud platform/ solution. Designed to meet UL864, 10th Edition/ VDS. Executing agency should have project name specified OEM authorization on the time of supply and also have at least one OEM certified engineer for commissioning & programming. Approved Make:-Siemens (Cerberus Pro)/ Johnson Controls/ Bosch/ Honeywell (Notifier)/ Schrack/ GAMEWELL only

-

-

-

... More
Two Loop Panel.

4

288168

1152672

... More
2)    Supply, installations, testing and commissioning of intelligent multisensor detector with integrated fault isolator/ isolator base. The intelligent multi criteria detector shall have integrated fault isolator/ fault isolator base as per NFPA style 7 to make ensure complete system working without losing any detector in case of cable fault. Be an addressable device that is designed to monitor a minimum of photoelectric and thermal technologies in a single sensing device. The design shall include the ability to adapt to its environment by utilizing a built in microprocessor to determine its environment and choose the appropriate sensing settings. This detector shall utilize advanced electronics that react to slow smouldering fires and thermal properties all within a single sensing device. Make:-Siemens (Cerberus Pro)/ Johnson Controls/Bosch/ Honeywell (Notifier)/ Schrack/ GAMEWELL only.

100

3049

304900

... More
3)    DSR Item No.17.2.12 :- Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or separate) complete with emitter and receiver including connections with remote test features etc complete as required. Approved Make:-Siemens (Cerberus Pro)/ Johnson Controls/Bosch/ Honeywell (Notifier)/ Schrack/ GAMEWELL only.

20

78309

1566180

... More
4)    Supply and installation of Red/ Green LED Laser etched emergency exit signage‘s double sided pendant type made out of powder coated MS housing and etched acrylic sheet indicator with reflective light source 2W LED, Emergency Backup of minimum 4 hours, 6V 3.2 AH SMF/ SLA battery, SMPS Power supply suitable for operation on 230 AV 50 Hz AC supply as per the requirement at all prominent locations to guide the way out of the building to the building users in case of fire. The size of the letter should be sufficient for visibility of the people as per NBC-2016. The exit sign board should be of Thorn/ Prolite/ Auto Glow/ Autolite/ Glowlite/ Honeywell make only.

15

3049

45735

... More
5)    Supplying, Installation, Testing & Commissioning of 480W Booster amplifier, Battery voltage 24Vdc (Max. 10% deviation), Frequency response 60Hz to 15 kHz (+1/-3 db), Distortion (at rated out power at 1 khz)-3%, Inputs- XLR, Impendence-20k, Sensitivity-1V (mic inputs), S/N-80 DB.

4

49088

196352

... More
Approved Make: Bosch/ JBL/ Bose only

-

-

-

... More
6)    DSR Item No.1.21:- Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
25mm dia

500

152

76000

... More
7)    DSR item No.17.3.2:- Supplying, installation, testing & commissioning of 1.5/3/6W Ceiling Speaker complete as required.

25

1008

25200

... More
8)    DSR item No.17.5.2:- Supplying & laying of 2x1.5 sq.mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

2800

181

506800

... More
9)    DSR item No.17.2.14:- Supplying, installation, testing & commissioning of addressable manual call point complete as required.

22

4045

88990

... More
10) DSR item No.17.2.6:- Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required.

23

2770

63710

... More
11) DSR Item No. 17.5.3.1:- Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the exiting surface/recessed steel conduit of following pairs, cores and sizes including connections and interconnections etc.

-

-

-

... More
Speaker Cable Single Pair, 2 Core, 1.5 sq.mm

500

56

28000

... More
12) DSR item No.17.3.9:- Supplying, Installation, Testing & Commissioning of Voice command Keypad 6 Zone, with microphone assembly complete as required.

4

85435

341740

... More
SCHEDULE NO. 3 (DG SETS)

-

-

-

... More
1)    Providing, Installing, Testing & Commissioning of 'Silent Type' Diesel Generating Set with AMF controller having Prime Power Rating of 320 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 volts suitable for 50 Hz. 3 phase system and for 0.85 Load Factor and consisting of the followings and as per CPWD specifications:

-

-

-

... More
[Note: - The DG Set Canopy should be DG Set OEM Manufactured only. No Franchises/ Authorized Partner of any manufactured accepted.]

-

-

-

... More
Diesel Engine

-

-

-

... More
Diesel Engine 4 stroke, water cooled, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to CPCB IV+ Emission Regulation, ISO 1460, ISO-8528, ISO-3046, ISO-9001 and ISO-13018 capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. The Engine should be of Greaves/ Kirloskar/ Cummins/ Caterpillar/ Volvo Penta/ Perkins/ Mitsubishi make only.

-

-

-

... More
Engine mounted Instrument Panel fitted with and having digital display for following:

-

-

-

... More
Start-stop switch with key

-

-

-

... More
Water temperature indication

-

-

-

... More
Lubrication oil pressure indication

-

-

-

... More
Lubrication oil temperature indication

-

-

-

... More
Battery charging indication

-

-

-

... More
RPM indication

-

-

-

... More
Over speed indication

-

-

-

... More
Engine Hours indication, Engine Protection Unit and Sensors for winding & bearing Temperature Monitoring.

-

-

-

... More
Alternator:

-

-

-

... More
Synchronous alternator rated at 320KVA or better, 415 volts at 1500 RPM, 3 phase 50Hz, AC supply with 0.8 lagging power factor at 40 degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS:60034-1 suitable for tropical conditions and with class F/H insulation. The alternator should be of Stamford/ Kirloskar/ Leroysomer/ Crompton/ Mitsubishi/ Caterpillar make only. The DG set should have provision of extended cable Termination Box to accommodate/ terminate 2 Run of 3.5 core x 300 sq.mm XLPE armoured, aluminium conductor cable.

-

-

-

... More
Base Frame & Foundation

-

-

-

... More
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on existing cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. The base frame of the diesel generating set shall be sturdy and fabricated/ welded construction out of M.S. channel iron base of suitable size for mounting the above engine & alternator. The base frame shall be suitably designed to simplify transportation, handling, slinging, E&C. This base frame shall be painted with anti-corrosive epoxy paint. Noise level shall not exceed 75 dB as per CPCB norms of noise. A set of anti-vibration pads shall be provided between base frame and engine alternator.

-

-

-

... More
Fuel Tank :

-

-

-

... More
Daily service fuel tank of 500 liters (minimum) capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.

-

-

-

... More
Exhaust System:

-

-

-

... More
Dry exhausts manifold with Hospital exhaust silencer and Catalytic convertor provided with suitable length & size of exhaust pipe including all supporting structure as per manufacture design.

-

-

-

... More
Exhaust Gas Treatment :

-

-

-

... More
Diesel Oxidation Catalyst

-

-

-

... More
Selective Catalyst Reactor

-

-

-

... More
Ammonia Slip Catalyst complying with CPCBIV+ along with On board diagnostics as per statuary requirement and remote monitoring.

-

-

-

... More
DEF/Adblue tank to be provided inside Acoustic Enclosure. DEF/Adblue should be as per ISO 22241 and make of DEF/Adblue should be as per OEM of DG set.

-

-

-

... More
Starting System

-

-

-

... More
12V/24V DC starting system comprising of starter motors voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries as required (25 plates, 180 Amps Hour Capacity Lead Acid type) as per specification. Make of the Lead Acid battery Exide/ Amara Raja/ Panasonic only.

-

-

-

... More
Acoustic and weather proof enclosure (outdoor type) with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications to accommodate item (a) to (f) above. The DG Set should meet the requirement of environmental latest CPCB-IV+ norms regarding emission and noise norms amended upto date. Sound proofing of the enclosure should be done with high quality fire retardant insulation material i.e. Rock wool/Glass wool/Mineral wool/ PU foam of appropriate thickness & density for sound absorption confirming to relevant IS to reduce the sound levels as per the latest CPCB Norms.

-

-

-

... More
Remote Monitoring Device:

-

-

-

... More
The DG Set should be provided with Remote Monitoring System to facilitate real time monitoring of performance, emission and service critical parameter for early diagnosis and to fix the issue before system breakdown.

-

-

-

... More
CPCB IV+ Certification:

-

-

-

... More
The bidder from the OEM of the DG Set should provide a certification of compliance with CPCB IV+ emission regulations from any of the authorised agencies mentioned in CPCB IV+ notification.

-

-

-

... More
The DG Set must have facility to start/ stop automatically when main supply failed/ restored.

-

-

-

... More
Warranty :

-

-

-

... More
The complete DG Set shall be warranted for 2 years or 5000 hours, whichever comes earlier, starting from the date of installation takeover by the department.

-

-

-

... More
Testing

-

-

-

... More
The complete DG Set before dispatch shall be tested as per the provisions of CPWD General Specifications for Electrical Works, Part-VII D.G. Set 2013 (Amended up to date), and relevant Indian Standards (IS provisions) in the workshop of OEM/OEA only.

2

3038350

6076700

... More
2)    Providing, Installing, Testing & Commissioning of 'Silent Type' Diesel Generating Set with AMF controller having Prime Power Rating of 200KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 volts suitable for 50 Hz. 3 phase system and for 0.85 Load Factor and consisting of the followings and as per CPWD specifications:

-

-

-

... More
[Note: - The DG Set Canopy should be DG Set OEM Manufactured only. No Franchises/ Authorized Partner of any manufactured accepted.]

-

-

-

... More
Diesel Engine

-

-

-

... More
Diesel Engine 4 stroke, water cooled, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL and conforming to CPCB IV+ Emission Regulation, ISO 1460, ISO-8528, ISO-3046, ISO-9001 and ISO-13018 capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. The Engine should be of Greaves/ Kirloskar/ Cummins/ Caterpillar/ Volvo Penta/ Perkins/ Mitsubishi make only.

-

-

-

... More
Engine mounted Instrument Panel fitted with and having digital display for following:

-

-

-

... More
Start-stop switch with key

-

-

-

... More
Water temperature indication

-

-

-

... More
Lubrication oil pressure indication

-

-

-

... More
Lubrication oil temperature indication

-

-

-

... More
Battery charging indication

-

-

-

... More
RPM indication

-

-

-

... More
Over speed indication

-

-

-

... More
Engine Hours indication, Engine Protection Unit and Sensors for winding & bearing Temperature Monitoring.

-

-

-

... More
Alternator:

-

-

-

... More
Synchronous alternator rated at 200KVA or better, 415 volts at 1500 RPM, 3 phase 50Hz, AC supply with 0.8 lagging power factor at 40 degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS:60034-1 suitable for tropical conditions and with class F/H insulation. The alternator should be of Stamford/ Kirloskar/ Leroysomer/ Crompton/ Mitsubishi/ Caterpillar make only. The DG set should have provision of extended cable Termination Box to accommodate/ terminate 3.5 core x 300 sq.mm XLPE armoured, aluminium conductor cable.

-

-

-

... More
Base Frame & Foundation

-

-

-

... More
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on existing cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. The base frame of the diesel generating set shall be sturdy and fabricated/ welded construction out of M.S. channel iron base of suitable size for mounting the above engine & alternator. The base frame shall be suitably designed to simplify transportation, handling, slinging, E&C. This base frame shall be painted with anti-corrosive epoxy paint. Noise level shall not exceed 75 dB as per CPCB norms of noise. A set of anti-vibration pads shall be provided between base frame and engine alternator.

-

-

-

... More
Fuel Tank :

-

-

-

... More
Daily service fuel tank of 285 liters (minimum) capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.

-

-

-

... More
Exhaust System:

-

-

-

... More
Dry exhausts manifold with Hospital exhaust silencer and Catalytic convertor provided with suitable length & size of exhaust pipe including all supporting structure as per manufacture design

-

-

-

... More
Exhaust Gas Treatment :

-

-

-

... More
Diesel Oxidation Catalyst

-

-

-

... More
Selective Catalyst Reactor

-

-

-

... More
Ammonia Slip Catalyst complying with CPCBIV+ along with On board diagnostics as per statuary requirement and remote monitoring.

-

-

-

... More
DEF/Adblue tank to be provided inside Acoustic Enclosure. DEF/Adblue should be as per ISO 22241 and make of DEF/Adblue should be as per OEM of DG set.

-

-

-

... More
Starting System

-

-

-

... More
12V/24V DC starting system comprising of starter motors voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries as required (25 plates, 180 Amps Hour Capacity Lead Acid type) as per specification. Make of the Lead Acid battery Exide/ Amara Raja/ Panasonic only.

-

-

-

... More
Acoustic and weather proof enclosure (outdoor type) with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications to accommodate item (a) to (f) above. The DG Set should meet the requirement of environmental latest CPCB-IV+ norms regarding emission and noise norms amended upto date. Sound proofing of the enclosure should be done with high quality fire retardant insulation material i.e. Rock wool/Glass wool/Mineral wool/ PU foam of appropriate thickness & density for sound absorption confirming to relevant IS to reduce the sound levels as per the latest CPCB Norms.

-

-

-

... More
Remote Monitoring Device:

-

-

-

... More
The DG Set should be provided with Remote Monitoring System to facilitate real time monitoring of performance, emission and service critical parameter for early diagnosis and to fix the issue before system breakdown.

-

-

-

... More
CPCB IV+ Certification:

-

-

-

... More
The bidder from the OEM of the DG Set should provide a certification of compliance with CPCB IV+ emission regulations from any of the authorised agencies mentioned in CPCB IV+ notification.

-

-

-

... More
The DG Set must have facility to start/ stop automatically when main supply failed/ restored.

-

-

-

... More
Warranty :

-

-

-

... More
The complete DG Set shall be warranted for 2 years or 5000 hours, whichever comes earlier, starting from the date of installation takeover by the department.

-

-

-

... More
Testing

-

-

-

... More
The complete DG Set before dispatch shall be tested as per the provisions of CPWD General Specifications for Electrical Works, Part-VII D.G. Set 2013 (Amended up to date), and relevant Indian Standards (IS provisions) in the workshop of OEM/OEA only.

2

2162320

4324640

... More
3)    Foundation of DG Sets (2 Nos. 320 KVA and 2 Nos. 200 KVA DG Set)

-

-

-

... More
[Note: - The foundation of DG Set shall be 400mm below the ground level and 300mm above the ground level and projected at least 250mm from the size of enclosure all around. The top of the plinth has to be properly levelled for proper alignment of the DG doors. Further internal earthing will brought out on the earthing point on the DG Set. The firm shall submit the detailed design of foundation from OEM of the DG Set after considering safe bearing capacity of soil for structural strength and proper installation of DG Set.]

-

-

-

... More
DSR item No. 2.6 (Civil)

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth 1.5m in width as well as 10sqmm (on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m disposal earth to be levelled and neatly dressed.

-

-

-

... More
i) All kind of soil.

53

173

9169

... More
DSR item No. 2.27 (Civil)

-

-

-

... More
Supplying and filling in plinth with jamuna sand under floors including, watering, ramming consolidating and dressing complete.

6.7

2066

13842.2

... More
DSR item No. 4.1.11 (Civil)

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level.

-

-

-

... More
1:5:10 (1 cement: 5 coarse sand derived from natural source : 10 graded stone aggregate 40 mm nominal size derived from natural source).

15.9

6023

95765.7

... More
DSR item No. 5.22.6 (Civil)

-

-

-

... More
Steel Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.

-

-

-

... More
Thermo-mechanically treated bars of grade Fe-500D or more

3600

105

378000

... More
DSR item No. 5.1.3 (Civil)

-

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and re-inforcement- all work upto plinth level:

-

-

-

... More
1:2:4 (1 cement: 2 coarse sand (Zone III) derived from natural source : 4 graded stone aggregate 20 mm nominal size derived from natural source).

47.7

8352

398390.4

... More
DSR Item No. 13.1.1 (Civil)

-

-

-

... More
12 mm cement plaster of mix :-

66

338

22308

... More
13.1.1 1:4 (1 cement: 4 fine sand)

-

-

-

... More
DSR Item No. 5.9.2 (Civil)

-

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for:

-

-

-

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

66

820

54120

... More
4)    DSR item No. 5.4 Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (with charcoal/coke and salt) as required.

16

7808

124928

... More
5)    DSR item No. 5.9 :- Supplying and laying 25 mm x 5 m mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)

160

150

24000

... More
6)    Supply and Laying of following size of XLPE insulated and PVC sheathed, armoured, aluminum conductor & served cable of working voltage upto 1100 Volt. grade confirming to IS 7098 (Part-I)-1988 (Amended upto date) to be laid in existing RCC/ HUME/ METAL Pipe/ on surface clamped with 40x3mm MS flat clamp / on cable tray clamped with 40x3mm MS flat clamp as required at site. The job includes the cost of making connections with suitable size of aluminium Lugs/ thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer in Charge. The cable should be of Polycab/ Havells/ Finolex/ R.R. Kabel/ KEI/ Universal/ RPG make only.

-

-

-

... More
300 Sq. mm. 3.5 Core

740

2773

2052020

... More
7)    DSR Item No. 14.16:- Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

640

385

246400

... More
8)    DSR Item No. 9.1:- Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3½ X 300 sq. mm (57mm)

8

1249

9992

... More
9)    Supply and Laying of 10 Core 2.5 Sq.mm Copper Conductor Armoured Cable to be laid in existing RCC/ HUME/ METAL Pipe as required at site. The job includes the cost of making connections with suitable size of aluminium Lugs/ thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer in Charge. The cable should be of Polycab/ Havells/ Finolex/ R.R. Kabel/ KEI/ Universal/ RPG make only.

740

675

499500

... More
SCHEDULE NO.4 (UPS)

-

-

-

... More
1)    Supply, Installation, testing and commissioning of 30 KVA/ 30 KW Online UPS with three phase AC input and three phase AC output with battery backup of 30 minutes with minimum 24000 VAH. The UPS should be of Microprocessor control double conversion, PWM/ IGBT based inverter with LCD display for monitoring of its status and provided with inbuilt /external isolation transformer. The job includes the cost of carriage, erection, commissioning and testing charges including rack, connecting and other petty material required to complete the job. The UPS should be of Vertiv/ Numeric/ Eaton/ APC make only. The battery bank enclosure should be fabricated from MS angle iron and MS sheet of suitable gauge to take the weight of battery banks and other parts and there will be no any extra charges will be paid. The UPS system with batteries shall be warranted for two years.

-

-

-

... More
The UPS should have following specification:-

-

-

-

... More
Manual by-pass facility.

-

-

-

... More
Switching device shall be IGBT. At rectifier & inverter.

-

-

-

... More
Input: 325VAC-475VAC 50 +/-3% Hz three phase AC

-

-

-

... More
Output: 400/415 VAC +/-1%

-

-

-

... More
Operating Temp. -00 C to 400 C

-

-

-

... More
Operating humidity:0-95%

-

-

-

... More
(Non-condensing)

-

-

-

... More
Total harmonics distortion at output: 3% maximum.

-

-

-

... More
Efficiency: overall efficiency (minimum 90%)

-

-

-

... More
UPS output power factor at rated load : Unity power factor

-

-

-

... More
Over load: UPS shall withstand 20% overload for 10 minutes and 50% over load for 1 min.

-

-

-

... More
Protections: following protection shall be provided in UPS.

-

-

-

... More
Over voltage, short circuit, and overload at UPS output terminal.

-

-

-

... More
Under voltage at battery terminal

-

-

-

... More
Over shoot and under shoot shall not be greater than 4% of rated voltage for duration of 40m sec. (over shoot is the abrupt increase of output voltage when the output load is changed from full-load to no.-load. Similarly, under shoot is the abrupt decrease of output voltage when the output load is changed from no to full load. )

-

-

-

... More
Audible Alarm operators on fault conditions

-

-

-

... More
Indicators and meters

-

-

-

... More
Mains presence.

-

-

-

... More
Battery charging and discharging

-

-

-

... More
Output overload

-

-

-

... More
Low battery voltage.

-

-

-

... More
Digital meter shall be provided for monitoring the following parameters in UPS (not applicable for rack mounting)

-

-

-

... More
Input AC voltage.

-

-

-

... More
Output AC voltage, current and frequency.

-

-

-

... More
Battery voltage and current.

-

-

-

... More
SMF Battery Bank

4

678450

2713800

... More
(Approved Exide/ Amaron/ Panasonic make only)

-

-

-

... More
2)    DSR item No.5.6:- Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

14461

57844

... More
3)    DSR item No.5.4:- Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (with charcoal/coke and salt) as required.

4

7808

31232

... More
4)    DSR item No.5.14:- Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required

120

1214

145680

... More
5)    DSR item No.5.15:- Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

120

255

30600

... More
SCHEDULE NO. 5 (LIFT)

-

-

-

... More
(HOME SCIENCE COLLEGE SECTOR-10)

-

-

-

... More
1)    Supply, installation, testing and commissioning of 13 Passenger 884 Kgs, 1.0 Mps (min.) lift having 2 stop and 2 opening all on same side, with Machine Room Less (MRL), having approximate travel 4 meters as per detailed technical specifications given below. The rates include the cost of minor civil works and steel items required for installation of lifts complete in all respect to the entire satisfaction of engineer-in charge.

-

-

-

... More
Type & Capacity13 Passenger 884 Kgs.

-

-

-

... More
Speed1.0 Meter Per Second (Minimum)

-

-

-

... More
Type of DriveA.C.V.3.F.- Microprocessor Based Control/VF Regenerative.

-

-

-

... More
Motor / Machine Electric traction gearless motor to be hoisted on guide rails within the elevator hoist way. (MRL)

-

-

-

... More
Travel Approximate 4 Meters (Ground to First Floor)

-

-

-

... More
Serving2 stops, 2 openings (All on same side )

-

-

-

... More
Hoist way Available1850 mm wide x 2450 mm deep.

-

-

-

... More
Car size1100 mm wide x 2000 mm deep with net height below ceiling 2200 mm (min). (Minimum Net Car inside area 2.06 Sq. Meter)

-

-

-

... More
Car Enclosure Constructed out of scratch resistant stainless steel Honeycomb finish/ Moonrock finish/ Hairline finish panels.

-

-

-

... More
Car & hoist way Door Constructed out of scratch resistant stainless steel Honeycomb finish/ Moonrock finish/ Hairline finish panels.

-

-

-

... More
Car entrance & Hoist way entrance Centre opening doors 900mm wide 2000mm high with provision of emergency key opening at all landings.

-

-

-

... More
Door Operation Automatic D.C. Power/ A.C.V.3.F. Door operation with adjustable door opening & closing timing.

-

-

-

... More
Control Simplex, full collective control with or without attendants.

-

-

-

... More
Operation A.C. variable voltage variable frequency.

-

-

-

... More
Power Supply415Volts + 10%, 3Phase ,50 Hz AC.

-

-

-

... More
Over Head available4800 mm

-

-

-

... More
Flooring Granite 18 mm thick.

-

-

-

... More
PIT available1800 mm Deep

-

-

-

... More
Levelling Accuracy+/-5mm Independent of load in the car.

-

-

-

... More
Indicator Digital Direction and position indicators in both car and at all landings.

-

-

-

... More
Guide Rails Tongue & Groove Guide Rails

-

-

-

... More
Maintenance Free Maintenance / Fortnightly Service for one year

-

-

-

... More
Safety & Buffers. As per I.S.I. Provisions.

-

-

-

... More
Fire Safety The Landing door and car door shall be fire rated as per national building code- 2016.

-

-

-

... More
Press & Speak intercom system among cars & reception. Luminous hall Braille buttons at all landing and inside the car.

-

-

-

... More
Steel items.

-

-

-

... More
Automatic Rescue Device to automatically bring the Elevators to a landing in case of power or controller failure provided with sealed maintenance free Batteries of suitable rating for 7 operations of ARD in a day with duration of 30 min. The batteries shall be of reputed make (Exide/ Amaron/ Panasonic only).

-

-

-

... More
Load weighing Device with over load by pass feature.

-

-

-

... More
Voice announcement system with music in the car to announce the position of the elevator as the car stops at a floor served by the elevator.

-

-

-

... More
Full height infra-red Safety curtain.

-

-

-

... More
Fireman Drive.

-

-

-

... More
Stainless steel panels in false ceiling

-

-

-

... More
Signal/ Accessories LCD/LED/Digital display in car/ Braille button/ PWD friendly.

-

-

-

... More
Car operating Panel with door open/close button.

-

-

-

... More
LED Lighting

-

-

-

... More
Alarm & Emergency light .(Concealed) with re-chargeable battery

-

-

-

... More
Over load Device.

-

-

-

... More
Fireman Switch.

-

-

-

... More
Air fan at Ceiling for air ventilation (16”sweep).

-

-

-

... More
Audio signal in case of emergency stop/any interruption should be provided in the lift car.

-

-

-

... More
Correction drive

-

-

-

... More
Hall lantern and gong at all landings

-

-

-

... More
Phase failure detection.

-

-

-

... More
Voltage stabilizer for control system.

-

-

-

... More
Additional car gate lock to prevent the car door to be opened hand rail on three side of car from inside the car in case the car is not at floor level.

-

-

-

... More
Installation & Commissioning The job includes installations, testing, commissioning as required to complete the work in all respect including cost of all material, T&P, Carriage & Labour etc.

-

-

-

... More
Civil Work The firm shall provide scaffolding, M.S. joint/ Channels, Pit ladders and minor Civil works etc. as required at no extra payment. The complete lifts including testing, commissioning and safety provisions shall conform to various Indian standard and rules with up to date amendments as mentioned below.

-

-

-

... More
Standard & Rules.IS 14665 (Part 1 to 3); 2000.IS 14665 (Part 5);1999.CPWD Specifications for Electrical Works Part-III Lift & Escalators- 2003 with up to date amendments

-

-

-

... More
General Technical Specifications As per CPWD general specifications Electrical Works Part-III Lift & Escalators 2003 and relevant IS code.

-

-

-

... More
Makes Kone/ Schindler/ Otis/ Johnson/ Mitsubishi/ Thyssen Krupp only.

1

1563669

1563669

... More
SCHEDULE NO. 6 (STAGE LIGHTING & FURNISHING WORK)

-

-

-

... More
1)    Side Wings:- Supply Installation testing and commissioning of providing and fixing cloth wings made out of Black Glazed Cotton Cloth not less than 300 GSM of make Mayur/ Omphile/ Nexgen with fixed both side of MS 50mm x 25mmx 16G pipe wielded frame work. The pipe framework made out of 25mm x 50 mm pipe. c/c 600 x 900 fixed with overhead pivote track complete with duly painted on both framework. Size : 1200mm x6000mm.

24

29880

717120

... More
2)    Supply Installation testing and commissioning of Providing & fixing of Main Frills in double gathering box pleats stitched out of Fire Retardant Velvet Fabric not less than 300 GSM of make Mayur/ Omphile/ Nexgen. The frill to be fixed from the suspension grid with 25mm dia B class MS Pipe suitably hung by mean of 35x4mm MS flat. The pipe & flat to be painted with black enamel paint.

4

38330

153320

... More
3)    Supply Installation testing and commissioning of Providing & fixing of frills in double gathering box pleats stitched out of Fire Retardant Glazed Black Fabric not less than 300 GSM of make Mayur/ Omphile/ Nexgen. The frill to be fixed from the suspension grid with 25mm dia B class MS Pipe suitably hung by mean of 35x4mm MS flat. The pipe & flat to be painted with black enamel paint.

8

34845

278760

... More
4)    Supply Installation testing and commissioning of MS Pipe Lighting Bar (fixed): to be provided at ON STAGE to be fixed from the existing main structure Girder/ Grid/ Beams/ Ceiling, approx. size 12m x 50mm dia B-Class, MS Pipe supported by A.I. brackets; duly painted black

16

38330

613280

... More
5)    Supply Installation testing and commissioning of Main Curtain made out of Crepe Curtain Cloth not less than 300 GSM of make Mayur/ Omphile/ Nexgen with horizontal sliding arrangement complete with fixing rails, brackets, sliding arrangement& motorised operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP motor (Crompton/ Siemens/ Godrej) 2 nos. air breaker contractor (L&T/ SIEMENS) , 2nos micro switches for auto stop, 3 Nos. puss buttons for forward, reverse and stop positions. The curtain should be draped to half area when is closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering can be operated manually of through remote.

4

348450

1393800

... More
6)    Supply Installation testing and commissioning of Rear Curtain made out of Treated black colour Crepe/Glazed Innovative Cloth not less than 300 GSM of make Mayur/ Omphile/ Nexgen with horizontal sliding arrangement complete with fixing rails, brackets, sliding arrangements & motorised operation complete with runners, master runners, pullies, 3mm steel wire rope, 1HP motor (Crompton/ Siemens/ Godrej) 2 Nos. air breaker contactors (L&T/SIEMENS), 2 nos. micro switches for auto stop, 3 Nos. push buttons for forward, reverse and stop positions. The curtain should be draped to half area when in closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering can be operated manually of through remote.

4

348450

1393800

... More
7)    Supply Installation testing and commissioning of Cyclorama Screen in plastic perforated material. The screen to be fixed on tubular frame made out of 35mm dia MS pipe. Appx. Size:- 8000mm x 6000mm. Approved Make:- Showtex/ GTC/ Canara Lighting only

192

5227

1003584

... More
8)    Supply Installation testing and commissioning of LED PAR: High Quality Bright LED Par Light with RGBW Colors source, High throw, Event Performance effect lighting, precision color output LED Par light made with die casted aluminum housing. 54 x 3W, 15°/30°/45°/60° RGB LED PAR of IP 20 rating, delivers 4200 Lumens. The fixture should have capability to work on standby mode, via DMX 512 or integrated sound- 2 light program. Power Consumption 180W, Input Voltage AC 100V ~ 240V, 50/60Hz 0 to 100 % smooth dimming, Strobe effect upto 20 Frames per Second (FPS). Approved Makes: Leksa/ Canara/ Modern Stage Lighting/ Effectron only.

72

21778

1568016

... More
9)    Supply Installation testing and commissioning of LED cyclorama light, Light source : 18 PCS 12W 4IN1 LEDs, Lens angle : 25º(30º, 45º, 60º optional), Channel mode : 3 / 4 / 6 / 7 / 9DMX channel mode 0-100% linear dimmer, Function : color mix, automatic color change, built-in program and strobe effect with adjustable speed Sound controlled via built-in microphone Adjustable sound sensitivity LED Display, easy to control, Control : auto, sound active, DMX512, software(connect to computer) Overheating protection Voltage : 100-220V,50/60hz, Power : 230W, IP rating : IP20(PLS-18 x 4in 1). Approved Makes: Leksa/ Canara/ Modern Stage Lighting/ Effectron only.

16

43556

696896

... More
10) Supply Installation testing and commissioning of 400W LED Blinder Light. 400W LED Blinder Light 30 Degree complete with 3200K/5600K CCT 4x100W Chip On Board LED lamp source, DMX 512 dimming with 4/8 Channel modes, Black finish housing, IP20 protection having Strobe option and smooth dimming, illuminate Stage with uniform light intensity levels. Approved Makes: Leksa/ Canara/ Modern Stage Lighting/ Effectron only.

16

52268

836288

... More
11) Supply Installation testing and commissioning of LED 200W Profile with Plastic housing (26 degree) Output Lux@2m 11000 Lux, Lightsource LED Qty 1pcs of 150W LED, Certification CE Working Environment. Approved Makes: Leksa/ Canara/ Modern Stage Lighting/ Effectron only.

20

95824

1916480

... More
12) Supply Installation testing and commissioning of Gattone Beam 200 (10R), Standard DMX512, automatic and master/ slave mode, Channel : 16CHs, Focus : Electronically Focus, Dimmer : 0-100% linear adjustment, Pan/Tilt : 540* for Pan, 250* for Tilt. Approved Makes: Leksa/ Canara/ Modern Stage Lighting/ Effectron only.

8

121958

975664

... More
13) Supply Installation testing and commissioning of Pearl-2410 DMX Lighting Desk : 240 Intelligent Fixtures + 240 Dimmer Channels; 2010 Channels ; Load and Save shows with USB ; Theatrical Plotting & Playback functions ; Shape Generator ; 15 Playback Masters controlling 450 memories, chases or cue lists MIDI and Sound to Light triggers ; VGA output ; supplied with LED lamp. Approved Makes: Leksa/ Canara/ Modern Stage Lighting/ Effectron only.

4

113246

452984

... More
14) Supply Installation testing and commissioning of Light Point Wiring from Patch Panel to be Light Point Wiring from Patch Panel to be with 1.5 Sq.mm 3 Core PVC Insulated and PVC Sheathed Cable including of suitable size for laying these wires including 16 amps metallic industrial clad sockets with box at top and FRLS cable.

104

9582

996528

... More
15) Supply, Installation, Testing and Commissioning of Die cast Aluminium C- Clamp with safety chain duly epoxy polyester powder coated in black matt texture finish and safe working load of 100kg with below specifications. Lock - MS threaded Galvanized lock key, Plastic Glass filled nylon moulded M6 key. Receptacle - 28mm standard TV spigot. Safety-MS Galvanized chain with pin. Finish-Pre-treated and black epoxy polyester powder coated.

104

523

54392

... More
16) DSR item No.10.2 (Civil):- Structural steel work riveted, bolted, or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing, in position and applying a priming coat of approved steel primer all complete.

5000

130

650000

... More
17) Supply Installation testing and commissioning of DMX Cable, Conductor (No./size of wire) 25/0.10mm Cross-Sectional Area 0.22 sq.mm (24 AWG), Insulation Material HDPE Insulation OD 1.10 mm, Insulation Colours Red/ Yellow Shield Conductor ATC Copper-(0.10mm)105 wires (approx.) Shield Type Serve Shield–also called Helical, or spiral Jacket Material High Flex Matt Finish PVC Jacket OD 6.00 mm +/– 0.10mm, Operating Voltage 300 V Operating Temperature -20⁰ C to +70⁰ C Dielectric Constant 1khz 2.3. Approved Make: - Falcon/ Beldon/ Polycab only.

800

261

208800

... More
Note: All passive accessories not included or missing from the BOQ but required for the smooth functioning of Stage Lighting shall be considered as included. No extra payment will be made on this account.

-

-

-

... More
SCHEDULE NO. 7 (VIDEO SYSTEM)

-

-

-

... More
1)    Supply, Installation, Testing and Commissioning of Digital Projection System of 14000 ISO Lumens Laser Phosphor projector WUXGA. Approved Make: - Christie/ Barco/ NEC only.

3

2806242

8418726

... More
WUXGA 14000 lumens laser projector

-

-

-

... More
Brightness14000 lumens

-

-

-

... More
Contrast4000000:1

-

-

-

... More
Type DLP laser projector

-

-

-

... More
§  3D Sync in (BNC) - for genlocking projectors3D Sync out (BNC) - for genlocking projectors or controlling emitter or polarizer HDMI 1.4, HD Base-T - frame packing, top/bottom, side-by-side/frame sequential (up to 120 Hz)

-

-

-

... More
Native Resolution1920X1200

-

-

-

... More
Illumination type Laser light source with 20000 hours life

-

-

-

... More
Inputs HDMI 2.0 x 2 (HDCP 1.4/2.2)DVI-D x 1 (Digital Only)RJ45 x 1 (HD Base T)RJ45 x 1 (Control over wired network connection)3G-SDI x 1 (BNC)USB x 1 (type A)RS232 in Built-in backlit keypad Wired remote control 3.5mm stereo - loop out available for daisy chaining

-

-

-

... More
ControlsRS232 In , Ethernet (10/100) RJ45

-

-

-

... More
Lens Motorized horizontal and vertical lens offset

-

-

-

... More
Operating voltage110-240 VAC 50/60Hz

-

-

-

... More
Operating environment5-40° C,10-80% non-condensing

-

-

-

... More
Pixel Clock594 MHz

-

-

-

... More
Warranty5 years

-

-

-

... More
Mount type Boresight adjustable

-

-

-

... More
Scan rate Horizontal: 15-91kHz, Vertical: 24-120Hz

-

-

-

... More
2)    Supply, Installation, Testing and Commissioning of Digital Projection System of WUXGA 19000 ISO Lumens Laser Phosphor projector WUXGA. Approved Make: - Christie/ Barco/ NEC only.

1

3813611

3813611

... More
Brightness 19000 lumens

-

-

-

... More
Contrast 4000000:1

-

-

-

... More
Type DLP laser projector

-

-

-

... More
3DHDMI 1.4, HD Base T – frame packed, top/bottom, side-by-side (up to 120Hz output);

-

-

-

... More
Frame sequential @1080p up to 120Hz.

-

-

-

... More
3D sync in (BNC) – for genlocking projectors

-

-

-

... More
3D sync out (BNC) – for genlocking projectors, or controlling emitter or polarizer Active shuttered and passive polarized stereoscopic 3D

-

-

-

... More
Native Resolution1920X1200

-

-

-

... More
Illumination type Laser light source with 20000 hours life

-

-

-

... More
Inputs HDMI 2.0b x 2 (HDCP 1.4/2.2) (one on rear panel, one on bottom) • 3G-SDI x 1 (BNC) DP x 1 HD BaseT (RJ45) x 1

-

-

-

... More
ControlsRS232 In , Ethernet (10/100) RJ45

-

-

-

... More
Lens Motorized horizontal and vertical lens offset

-

-

-

... More
Operating voltage110-240 VAC 50/60Hz

-

-

-

... More
Operating environment5-40° C,10-80% non-condensing

-

-

-

... More
Pixel Clock600 MHz

-

-

-

... More
Warranty5 years

-

-

-

... More
Mount type Boresight adjustable

-

-

-

... More
Scan rate Horizontal: 15-91kHz, Vertical: 24-120Hz

-

-

-

... More
3)    Supply, Installation, Testing and Commissioning of motorised projection Screen 7000X4600mm with LVC control complete with all mounting accessories. Approved Make:- Dalite/ Chief/ Draper only.

4

863459

3453836

... More
4)    Supply, Installation, Testing and Commissioning of 42/43 inch 4K Mainstream Professional Display for AVSI & Digital Signage Project with New symmetrical slim Design, Intelligent UHD up-scaling, Dynamic Crystal Color, Narrow Bezel Design, Slim and Flat back Design and Web Browsing facility, 4000:1 Contrast Ratio, Stereo Mini Jack, HDMI, RS232, USB, RJ45, Wi-Fi built-in, Built-in-Speakers, EDGE LED, Haze coating, PC Less Configuration, VM Ware Horizon, Quad-Core CPU, 8GB Storage, 8MS Response time, EMC class B compliant, EPEAT Reg., IP5X for Dust Proofing, HDR+, 3840x2160 (16:9) 16/7 operation. Approved Make:- Samsung/ Sony/ LG only.

14

48000

672000

... More
5)    Supply, Installation, Testing and Commissioning of 85/86 inch 4K Mainstream Professional Display for AVSI & Digital Signage Project with New symmetrical slim Design, Intelligent UHD up-scaling, Dynamic Crystal Color, Narrow Bezel Design, Slim and Flat back Design and Web Browsing facility, 4000:1 Contrast Ratio, Stereo Mini Jack, HDMI, RS232, USB, RJ45, Wi-Fi built-in, Built-in-Speakers, EDGE LED, Haze coating, PC Less Configuration, VM Ware Horizon, Quad-Core CPU, 8GB Storage, 8MS Response time, EMC class B compliant, EPEAT Reg., IP5X for Dust Proofing, HDR+, 3840x2160 (16:9) 16/7 operation. Approved Make:- Samsung/ Sony/ LG only.

4

252700

1010800

... More
Switching and Interface System

-

-

-

... More
6)    Supply, Installation, Testing and Commissioning of Digital Interactive Podium in Metallic Frame and Wooden Top with 21 inch Full HD (Electromagnetic + Capacitive) (including white baord facility) Interactive Display with Electromagnetic Pen, with Motorized Tilting of the Interactive Panel, with Gooseneck Microphone with ON/OFF and mute button, Interactive panel, Keyboard Tray, Visualizer Tray and space to store AV equipment, Interactive display with full HD resolution of 1920x1080, Technology IPS LCD, Aspect ratio16:9, Brightness 250 cd/m2, Contrast ratio1000:1, Pen Type shall be Pressure-sensitive and cordless. Top connectivity plate with HDMI, USB x 2, VGA + Audio and Power socket for external Laptop connectivity, built-in 4 x 2 HDMI Matrix Switcher with 4K@60Hz (4:4:4, 8- bit) as well as support for 16-bit Deep Colour, HDR (High Dynamic Range), 3D content, HD audio and other features defined by HDMI 2.0 specification and Audio De-embedder for internal connectivity. Approved Make:- AHA/ UNI/ Tecom only.

4

287820

1151280

... More
7)    Supply, Installation, Testing and Commissioning of Wireless presenter system, Includes 1x HDMI IN and 1xHDMI Out, 1xRS232, 1xEthernet Ports. Supports presentation from MacOS, iOS, Android, Windows, ChromeOS. Resolution 1080p60. Should offer customisable welcome screen, logosetc. Approved Make:- Mersive/ Kramer/ Barco only.

4

172692

690768

... More
8)    Supply, Installation, Testing and Commissioning of Wall/Floor Plate with 1xHDMI, 1xDP/VGA, RJ45 Ports, complete with Transmitter, Receiver set. Approved Make:- Logic/ Kramer/ Lightware only.

8

14391

115128

... More
9)    Supply, Installation, Testing & Commissioning of Network Video Endpoint configured as Encoder. Minimum Inputs - 1 x HDMI Input and 1 x USB-C for single cable connectivity for Video encoding, AV USB Bridging- emulating webcam video and AEC speakerphone audio driver for Software based Video Conferencing and for charging the connected device. Local- Output - 1x HDMI with Scaling, HDMI audio embedding and deembedding, Network Audio supported via Dante/ AES67 or similar protocol, Video Resolution - 4K60 4:4:4 or better. Power -PoE and AUX, Control Port - RS232 or better, Mounting hardware included. Approved Make:- QSC/ Kramer/ Crestron only.

8

341498

2731984

... More
10) Supply, Installation, Testing & Commissioning of Network Video Endpoint configured as Decoder. Outputs -1xHDMI with scaling or better. Local Inputs - 1xHDMI and 1xUSB-C for local switching. Audio embedding and deembedding, Network Audio supported via Dante/ AES67 or similar protocol. Video Resolution - 4K60 4:4:4 or better. Power - PoE and AUX, Control Port - RS232 or better, Mounting hardware included. Approved Make:- QSC/ Kramer/ Crestron only.

8

341498

2731984

... More
Processing and Control System

-

-

-

... More
11) Supply, Installation, Testing & Commissioning of Digital Signal Processor with 12 Mic/Line inputs and 12 Line outputs. Minimum 12 assignable & routable AEC channels. Minimum 8x8 Dante channels and supports up to 128x128 Network audio channels via Dante/AES67 or similar. POTS and SIP Soft phone integration for Audio conferencing and configurable 16x16 USB Audio channels. The processor shall support third party device control via Ethernet, RS232. Approved Make:- QSC/ Biamp/ Symetrix only.

4

546857

2187428

... More
12) Supply, Installation, Testing & Commissioning of Software and Hardware based control system with following specifications:- High Definition, Multi-touch Touch Screen Controller with 24-bit color display. Viewable Screen Dimensions (diagonal) - 7-inch, Resolution - 1280 × 800, Brightness - 400 Nits, Aspect ratio – 16:10, Power - PoE, Mounting - Wall and Tabletop, Orientation - Vertical/ horizontal. Configurable LEDs on both side. (b) Having Features to control equipment having IR / GPIO control For Ambient Lighting , Curtain Movement, Audio -Video System On-Off, Volume Control, Camera Control etc.. (c)   Should include perpetual licenses as required. Approved Make:- QSC/ Biamp/ Symetrix only.

4

391435

1565740

... More
13) Supply, Installation, Testing and Commissioning of a set of Wi-Fi Routers & Satellite having ‎10 Gbps, 2.5 Gbps WAN Port, 4804 Mbps (5 GHz) + 1148 Mbps (2.4 GHz), 2.5 Gbps WAN port and eight Gigabit LAN ports, 2 USB 3.0 in Type A and Type C, Processing – 1.8 GHz Quad-Core CPU and 3 coprocessors, ‎Bluetooth, 5 GHz Radio Frequency, 2.4 GHz Radio Frequency‎, GSM Frequency 1800 MHz. Approved Make:- Juniper/ Cisco/ HP/ Allied Telesis only.

4

143910

575640

... More
14) Supply, Installation, Testing and Commissioning of 24 port preconfigured Network switch for AVoverIP. 24x PoE++ Ports and 1440 Watts PoE budget. Features advanced QoS and IGMP configuration to support AES67 and Dante within the same VLAN. Approved Make:- QSC/ Cisco/ Juniper only.

4

575639

2302556

... More
15) Supply, installation, testing and commissioning of 4K UHD, 60fps, PTZ Camera with minimum 30x Optical Zoom, 12x Digital Zoom, 1/2.5" 8.5 MP CMOS Sensor featuring HDMI/ SDI/ Ethernet output, Control: RS232/ Ethernet Including wall/ ceiling mounting accessories. Make: Lumens / Sony / Vaddio only.

4

282783

1131132

... More
16) Supply, Installation, Testing and Commissioning of Recording and Streaming Server having minimum HDMI, VGA, LAN inputs etc to which various components like Presenter Laptop/ PC, Full HD PTZ Cameras, Document Cameras, etc can be connected to record upto 4 inputs simultaneously on the single frame alongwith Audio. It should be able to Capture from Multiple Sources and able to Record and Stream upto min Four Full Motion HD Videos simultaneously in one frame upto 1080p resolution. The system should support upto min 4 Channel Mixing and Switching where the user can do live recording of the Lecturers as per the requirement. The system should have one HDMI/ DVI / VGA output for the Projector or for confidence monitor for the presenter. The system should come with min 1 TB of in-built hard disk for storing upto 400-500 Hours of recording. The system should have a facility to further extend the memory through USB or e-SATA Hard Disk. System should support multiple encoding rates, multiple frame rates, Auto Logo Insertion during recording. System should also be able to support Webcast, Unicast and Multicast as Streaming Solution. The system should be able to support Video Processing at different frame rates upto 30 fps; Multiple Bit Rate from 64kps to 24Mbps in Full HD Resolution of 1080p. Approved Make:- Meidasite/ Media Pointe/ Lumens only.

3

765600

2296800

... More
Cable, Connectors and Accessories:-

-

-

-

... More
17) Supply, Laying, Testing & Commissioning of Microphone Cable 23/0.76 ATC PVC Sheathed. Approved Make:- Belden/ Krystal/ Canare only.

2000

317

634000

... More
18) Supply, Laying, Testing & Commissioning of Speaker Cable, 2 Core 4 Sq.mm. stranded ETP high-conductivity copper conductors, PVC insulation, parallel: (1) tinned, (1) bare etc. complete with installation as per the site requirement. Approved Make:- Belden/ Krystal/ Canare only.

4000

230

920000

... More
19) Supply, Laying, Testing & Commissioning of 18Gbps HDMI Cables (Varied sizes as per site requirement). Approved Make:- Belden/ Krystal/ Canare only.

20

79150

1583000

... More
20) Supply, Laying, Testing & Commissioning of 8 pair twisted CAT-6A cable complete with installation as per the site requirement. Approved Make:- Belden/ Krystal/ Canare only.

3500

223

780500

... More
21) Supply, Laying, Testing & Commissioning of Loudspeaker and microphone connector boxes with amphpenol/ neutrik connectors.

31

6476

200756

... More
22) Supply, Laying, Testing & Commissioning of 32U Equipment rack having depth of 800mm or better. It should have min 3 slabs and have features of internal wiring, front glass door, heat dissipation fans, movement wheels and power distribution units. Approved Make:- Valrack/ Rittal/ WQ only.

7

64759

453313

... More
SCHEDULE NO. 8 (AUDIO SYSTEM)

-

-

-

... More
1)    Supply, Installation, Testing & Commissioning of FOH Line Array Loudspeaker System. Two-way passive/bi-amp line array loudspeaker array module. LF Transducer - Single 8-inch with 2-inch voice coil or better, HF Transducer - Compression driver, 1.75-inch voice coil or better, Frequency Range - 65Hz-20 kHz or better, Sensitivity - 100dB or better, Max continuous SPL - 126dB or better. Power Continuous - 250W or better, Horizontal Coverage - 100° or better, Vertical Coverage - 15° or better. Approved Make:- QSC/ Bose/ Martin Audio/ TW-Audio/ Renkus-Heinz only.

16

405073

6481168

... More
2)    Supply, Installation, Testing & Commissioning of FOH Line Array Loudspeaker System. Two-way passive/bi-amp line array loudspeaker array module. LF Transducer - Single 8-inch with 2-inch voice coil or better, HF Transducer - Compression driver, 1.75-inch voice coil or better, Frequency Range - 65Hz-20 kHz or better, Sensitivity - 100dB or better, Max continuous SPL - 126dB or better. Power Continuous - 250W or better, Horizontal Coverage - 100° or better, Vertical Coverage - 15° or better. Approved Make:- QSC/ Bose/ Martin Audio/ TW-Audio/ Renkus-Heinz only.

16

405073

6481168

... More
3)    Supply, Installation, Testing & Commissioning of Passive subwoofer in bass reflex enclosure. Transducers - 15-inch with 4-inch voice coil. Continuous Power - 900W or better, Frequency Range - 38-100Hz or better, Sensitivity-97dB or better, Max continuous SPL - 139dB or better, Omni-directional or cardioid radiation modes. Approved Make:- QSC/ Bose/ Martin Audio/ TW-Audio/ Renkus-Heinz only.

8

351063

2808504

... More
4)    Supply, Installation, Testing & Commissioning of 18-inch externally powered subwoofer. Frequency Range (-10 dB) - 32 Hz to 230 Hz, Frequency Response (-6 dB) - 37 Hz to 230 Hz. Nominal Impedance-4Ω, Power capacity - 800W, Sensitivity -98 dB, 1 W@1m, Maximum Peak SPL-133 dB. Enclosure-Rectangular, plywood, black texture paint finish. Approved Make:- QSC/ Bose/ Martin Audio/ TW-Audio/ Renkus-Heinz only.

2

113810

227620

... More
5)    Supply, Installation, Testing & Commissioning of 10-inch, Full range, 2-Way Passive Loudspeaker. Frequency Range (-10 dB)-50 Hz – 20 kHz, Power capacity - 300W, Sensitivity-95 dB, Maximum Peak SPL-126dB, Coverage Angle-85° conical, LF Driver - 10-inch with 2.5-inch Voice Coil or better, HF Driver- 1-inch Exit, 1.75-inch voice coil, compression driver or better. Nominal Impedance-8Ω, Enclosure-Trapezoidal, plywood, black texture paint finish, Perforated, powder-coated steel grille or similar. Mounting and suspension-9×M8 suspension points. Complete as per site. Approved Make:- QSC/ Bose/ Martin Audio/ TW-Audio/ Renkus-Heinz only.

18

121522

2187396

... More
6)    Supply, Installation, Testing & Commissioning of 12-inch Two-way active Stage Monitor Loudspeaker. Amplifier module - 1000 Watt peak power Class-D or better. LF Transducer- 12-inch cone or better, HF Transducer - 1.4-inch compression driver or better, Frequency Range (-10 dB)-47 - 20 kHz or better, Nominal Coverage Angle- 75° Axisymmetric or better, Maximum rated SPL - 126 dB or better, Indicators - Power LED, 2 × Input Signal LED, Input B MIC selected LED, Limiter active LED etc. or similar, Enclosure Material-Polypropylene or similar. Approved Make:- QSC/ Bose/ Martin Audio/ TW-Audio/ Renkus-Heinz only.

8

99919

799352

... More
7)    Supply, Installation, Testing & Commissioning of Quad Channel Class-D Network Amplifier. Total Power - 8000W or better, which can be asymmetrically distributed across amplifier channels. Should support 16Ω,8Ω,4Ω,70V,100V on each channel individually. Amplifier shall support power sharing and bridge and parallel modes for combining multiple channels. Frequency Response (8 Ω)-20Hz- 20kHz or better, Noise Weighted output muted-104 dB or better, Input impedance-8k balanced and 4k unbalanced or better, Front Panel Display for Indication and Control with Knobs and buttons or better. 4 or More Routable Mic/Line Inputs or better. Ethernet Ports - 2 Gigabit Ethernet ports for network redundancy or better. Approved Make:- QSC/ Bose/ Martin Audio/ Lab-Gruppen only.

8

810147

6481176

... More
8)    Supply, Installation, Testing & Commissioning of Passive Two-way, wall-mount speaker. Impedance- 8Ω and 70V/100V transformer taps, Frequency Range-60 Hz – 20 kHz, Sensitivity-86 dB or better. Coverage- 130° conical or better, Maximum peak SPL- 107 dB, LF Transducer 6.5-ich or better, HF Transducer - 1-inch or better. Should include the mounting kit. Approved Make:- QSC/ Bose/ Martin Audio/ TW-Audio/ Renkus-Heinz only.

24

32405

777720

... More
9)    Supply, Installation, Testing & Commissioning of 4 channel class-D amplifier with 100 watts/channel @8Ω/4Ω.Should support 70V/100V in bridge mode. Signal to Noise 100 dB or better, Frequency Response-20 Hz - 20 kHz or better, Front Panel Indicators-Power, per channel Signal, Protect/Limit or better. Energy Star compliant is better with all mounting accessories. Approved Make:- QSC/ Bose/ Martin Audio/ Lap-Gruppen only.

4

178231

712924

... More
10) Supply, Installation, Testing and Commissioning of OEM Supplied Array Frame for Line Array Speakers. Material - Aluminium. Speakers. 10:1 Design Factor or better. Approved Make:- QSC/ Bose/ Martin Audio/ TW-Audio/ Renkus-Heinz only.

8

129624

1036992

... More
11) Supply, Installation, Testing & Commissioning of 32 Channel Touch Screen Digital Mixer. 10-inch Color TFT Screen, 24 Mic/Line Inputs, 6 Line Inputs, Stereo USB/MP3 Playback, 4 Band Parametric EQ, Gate & Compressor Input Processing, Balanced Main LR Output on 2 x XLR (Line Level), 14 x Balanced Aux Outputs on XLR (Line Level), Stereo TRS Headphone Output, Stereo TRS Monitor L/R Output, 1/3 Octave Graphic EQ, 6 Band Parametric EQ, Variable High & Low Pass filters, 12-Band Anti-Feedback Filters, Limiter, Delay Output Processing, Stereo mp3 & 32 x 32 Multi track Recording & Playback direct to hard drive & DAW, 8 DCA & Mute Groups, External Control using wifi enabled iOS or Android devices, Selectable 44.1 kHz to 48 kHz Sampling Frequency. 48V Phantom Power Individually Switchable on all Mic Inputs complete with required snake cables as per site. Approved Make:- QSC/ Allen & Heath/ DiGiCo/ Yamaha/ Midas only.

4

378068

1512272

... More
12) Supply, Installation, Testing & Commissioning of Gooseneck Microphone, it should be pre-polarised condenser microphone having Cardioid or better polar pattern, shall have frequency response of 50Hz to 20kHz, length of the gooseneck shall be more than 420mm, Should have Max SPL Level of 125dB or more, it should support phantom power from 12v to 48v, Should come with base having programmable mute/un-mute button, Should be RF interference free from other wireless devices, should have muted/un-muted status LED Indication etc complete required as per the specifications. Approved Make:- Sennhesier/ Shure/ Revolabs only.

4

73929

295716

... More
13) Supply, Installation, Testing & Commissioning of Digital Wireless Lapel microphone with Omni directional or better polarity pattern, Frequency range: 471 - 797 MHz or better, THD total harmonic distortion ≤ -60 db for 1kHz @ -3 dBfs input level or better ; Switching bandwidth up to 56 MHz or better; up to 2240 selectable Frequencies for allow fine tuning, equidistant tuning grid of 600kHz to enable up to 90 simultaneous channels. Sensitivity in free field 17 mV/Pa or better, Sound pressure level 130 dB SPL or more. RF output 10mW or more, up to 8 hours of operating time or better, Audio Frequency Response of 20Hz-20kHz (-3db) @3dbfs, Bluetooth connectivity with mobile devices for basic setup and control of the receiver, should come with rechargeable lithium-ion battery complete with standard accessories. Approved Make:- Sennhesier/ Shure/ Revolabs only.

4

120118

480472

... More
14) Supply, Installation, Testing & Commissioning of Digital Wireless hand held microphone with cardioid polarity pattern, Frequency range: 471 -797 MHz or better, THD total harmonic distortion ≤ -60 db for 1kHz @ -3 dBfs input level or better; Switching bandwidth up to 56 MHz or better; up to 2240 selectable Frequencies for allow fine tuning, equidistant tuning grid of 600kHz to enable up to 90 simultaneous channels. Sensitivity 2.1 mV/Pa or better, Sound pressure level 150 dB SPL or more. RF output 10mW or more, up to 8 hours of operating time or better, Audio Frequency Response of 20Hz-20kHz (-3db) @3dbfs, Bluetooth connectivity with mobile devices for basic setup and control of the receiver, should come with rechargeable lithium-ion battery complete with standard accessories & USB charger. Approved Make:- Sennhesier/ Shure/ Revolabs only.

6

120118

720708

... More
15) Supply, Installation, Testing and Commissioning of Active antenna splitter 2 x 1:4 or 1 x 1:8, transmission operating in the UHF spectrum, Auto scan features, 134 dB or better audio input dynamic range , 56 MHz of tuning bandwidth and provision up to 90 channels, 2,200 or more selectable frequencies, with required antenna connection cables. Approved Make - Sennhesier/ Shure/ Revolabs only.

4

95438

381752

... More
16) Supply, Installation, Testing and Commissioning of directional antenna with Impedance: 50 Ohm; Connector: BNC; Pick-up pattern: directional; Frequency range: 470 - 1075 MHz; Antenna gain: 5 dBi or better, should come with connection cable and antenna mounting kit complete as required as per site. Approved Make:- Sennhesier/ Shure/ Revolabs only.

4

78390

313560

... More
17) Supply, Installation, Testing and commissioning of antenna Cable, the antenna cable should have impedance of 50 ohm only, Should be LMR 400 Standard, should be compatible with the wireless microphone system complete as required. Approved Make:- Belden/ Krystal/ Canare only.

8

3187

25496

... More
18) Supply, Installation, Testing and commissioning of Wired Instrument and Vocla microphones. Approved Make:- Sennhesier/ Shure/ Revolabs only.

12

13543

162516

... More
19) Supply, Installation, Testing and commissioning of wall mount 6.5-inch speaker with 70V/100V transformer taps at 30/15/7.5W for the lobbies including player for the content. Approved Make:- QSC/ Martin Audio/ Clair Brothers only.

26

31069

807794

... More
20) Supply, Installation, Testing and commissioning of amplifier for BGM system with 500W/channel @ 70V/100V. Approved Make:- QSC/ Martin Audio/ Power soft only.

2

398322

796644

... More
Total (Electrical Installation Work, Fire Detection & Alarm System, DG Sets, UPS, Lift, Stage Lighting, Video System and Audio System)

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.