Chandigarh Administration Tender

View complete overview of Chandigarh Chandigarh Administration Tender

Chandigarh Administration Tender

Civil And Construction
Building Construction
Eprocure
Opening Date4 Jan 2022
Closing DateCancelled
Tender Amount₹ 3,22,14,781 
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Installation, Testing and Commissioning of Water cooled Screw Chiller with VFD having 100 TR capacity and following technical parameters

-

-

-

... More
Chilled Water IN : 54 deg F / 12.2 º C

-

-

-

... More
Chilled Water Out : 44 deg F / 6.7 º C

-

-

-

... More
Chilled Water Flow : 288 USGPM / 65.41 m3/hr

-

-

-

... More
Pressure Drop Evaporator Side : 7 m

-

-

-

... More
Fouling Factor Evaporator Side : 0.0005 FPS

-

-

-

... More
Condenser Water IN : 90 deg F / 32.2 º C

-

-

-

... More
Condenser Water Out : 97.5 deg F / 36.4 º C

-

-

-

... More
Condenser Water Flow : 400 USGPM / / 90.85 m3/hr

-

-

-

... More
Pressure Drop Evaporator Side : 4 m

-

-

-

... More
Fouling Factor Evaporator Side : 0.001 FPS

-

-

-

... More
COP at ARI Conditions : 5.8

-

-

-

... More
Power Consumption at 100% load at design conditions : 0.68 kW/TR

-

-

-

... More
Integrated Part Load Value ( IPLV ) : 0.38 kW/TR

-

-

-

... More
The Chillers shall be AHRI Certified /accordance with AHRI to be certified by the OEM

-

-

-

... More
BMS Compatible

-

-

-

... More
First Charge of Environment Friendly HFC- 134 A and Oil ( Factory Charged )

-

-

-

... More
The evaporator  and condender shall have  ASME Stamping with Multi pass system only

-

-

-

... More
Shell & Tube type evaporator and condenser with totally enhanced copper tubes with flanged ends.

-

-

-

... More
Factory Insulation of Cold surfaces , closed cell rubber insulation.

-

-

-

... More
Country of Origin : India

-

-

-

... More
The price should include carriage, loading, unloading and cost of Civil Work including Foundation ( as recommended by the OEM ) Also 1 no. Chiller is to be witness tested at AHRI certified test bed in OEM factor for 4 load points , the cost of the same if any shall also be included in the rates quoted. The other 2 chillers shall be visual inspected.

-

-

-

... More
Make:- Carriar, Blue Star, Voltas, Daikin

-

-

-

... More
Chiller 100 TR (Actual Capacity)

3

-

2434119

... More
HOT WATER GENERATOR

-

-

-

... More
Supply, Installation, testing & Commissioning of electrically operated Hot Water Generator of 120 KW capacity, Tanks Shell made of 8 mm M.S. sheet , dish end made of 10mm M.S. Sheet, 16 gauge SS-304 grade lining with heaters arranged in banks and Controller and Thermostat so that suitable GPM hot water is generated at 50°C with nominal variation, including 75mm thick resin bonded fibre glass insulation of 24 Kg / CUM density finished with 1.25mm thick aluminium sheet cladding including necessary Electrical panel with BMS compatible having suitable Incoming and outgoing Switchgears for Boiler, automatic Controls including inlet and outlet connections for water complete with pressure release valve, low level cut-out, Autovent sight-glass as per specification complete as required. (Degree of protection IP52 with IS 2147),

-

-

-

... More
The price should include carriage, loading, unloading and cost of Civil Work including Foundation ( as recommended by the OEM )

-

-

-

... More
Make:- Rapid Cool, KEPL, Emerald

-

-

-

... More
Heating Capacity 120 KW

2

-

240412

... More
PUMP SETS

-

-

-

... More
PRIMARY VARIABLE SPEED CHILLED WATER PUMP SETS

-

-

-

... More
Supply, installation, testing and commissioning of Variable Speed Split Coupled Vertical In line Pump for chilled water recircualation and as per following specifications.

-

-

-

... More
Efficiency : 75% ( Min )

-

-

-

... More
Casing ( Volute ) : Ductile Iron

-

-

-

... More
Impeller & Pump Shaft : SS 316

-

-

-

... More
Mechanical Seal - Outside balanced

-

-

-

... More
Flow Rate : 240 USGPM / 54.5 m3 / hr

-

-

-

... More
Head : 32 m

-

-

-

... More
NPSHR : 6.27 mtr +/- 10%

-

-

-

... More
Rating : PN 16

-

-

-

... More
Motor : Enclosure : TEFC, Min. Efficiency : IE 3, Insulation Class F

-

-

-

... More
VFD - Integrated Mounted over Pump motor for sensorless/ wireless Integrated DPT control with IP-55 Protection shall be Integrated fliter to meet EN61800-3 for RFI Control, integrated DC link Reactor equivalent in performance to a 5% AC line reactor. The VFD LCD should display the dynamic head & flow rate at any point of operation,

-

-

-

... More
DPT control with IP-55 Protection shall be Integrated fliter to meet EN61800-3 for RFI Control along with 3 No. DPT (in case of wireless)

-

-

-

... More
Make:- XYLEM, Grundfoss, Armstrong

-

-

-

... More
Pumps as mentioned above

3

-

292266

... More
The price should include carriage, loading, unloading and cost of Civil Work including Foundation ( as recommended by the OEM )

-

-

-

... More
The system shall be complete in all respects and suitable for following ratings and duty.

-

-

-

... More
Microprocessor Based Pump Logic Controller for Primary variable pumps

-

-

-

... More
SITC Separate ( not as apart of VFD )Microprocessor based Primary variable pump logic controller in IP 54 protection, to control following nos. Pumps. Suitable to operate on Sensorless/ wireless mode ( 3 wireless DP sensor to be consider for each zone) & Should be Modbus RTU/ BACnet enabled for communicating with BMS & RS-485 serial communication with Pump VFD. The staging of pumps should be based on efficiency (not on capacity) to ensure minimum operating cost. End of curve protection should be sensorless control based Power Rating: 230 V/ 1 ph/ 50 Hz Display: Minimum 4.3" backlit LCD Hand-Off-Automatic (H-O-A) control Secure front cabinet door with lock and key UL Listed and CSA Approved Remote or local start/stop mode of operation. 2-level (field and factory) password security Remote zone signals, zone faults, zone setpoint and active control zone Note : All above should be sourced from OEM as a single unit

-

-

-

... More
Make:- XYLEM, Grundfoss, Armstrong

-

-

-

... More
For Chilled water pumpset (3W)

1

-

273534

... More
CONDENSOR WATER PUMPS (FIXED SPEED)

-

-

-

... More
Supply, installation, testing and commissioning of Fixed Speed Split Coupled Vertical In line Pump for condenser water recircualation and as per following specifications.

-

-

-

... More
Efficiency at Design : 73% ( Min )

-

-

-

... More
Casing ( Volute ) : Cast Iron - E - coated

-

-

-

... More
Impeller : Bronze & Pump Shaft : SS 416

-

-

-

... More
Mechanical Seal - Outside balanced

-

-

-

... More
Flow Rate : 400 USGPM / 54.5 m3 / hr

-

-

-

... More
Head : 36 m

-

-

-

... More
NPSHR : 5.08 mtr +/- 10%

-

-

-

... More
Rating : PN 16

-

-

-

... More
Motor : Enclosure : TEFC, Efficiency : IE 3, Insulation Class F

-

-

-

... More
Make:- XYLEM, Grundfoss, Armstrong

-

-

-

... More
Pumps as mentioned above

3

-

199131

... More
The price should include carriage, loading, unloading and cost of Civil Work including Foundation ( as recommended by the OEM )

-

-

-

... More
Cooling Tower (CTI Certified)

-

-

-

... More
Supply, installation, testing and commissioning of CTI Approved standard Rectangular type FRP Induced Draught Counter flow cooling tower , Motors suitable for VFD's with necessory accessories, Motors shall be IP65 and efficiency of IE3 , FRP water basin, PVC fillings with integral louvers and drift eliminators, hot water distribution by gravity complete with statically and dynamically balanced axial flow Fans, Direct driven fans with TEFC induction motor and temperature sensor suitable for operation on 415 + 10% volts, 50 Hz. AC supply, suction screen, make up with float valve and quick fill arrangement, overflow and drain connections, suitable inspection ladder, access arrangement for cooling tower interior, MS supporting structure, anti-vibration mountings ,cement concrete foundation, steel/ mesonary supporting structure complete as per specifications as required. Design shall be as below ,IP 55 rated Locable Isolator Switch with cooling tower along with all Isolators for CT Complete in all repsect .

-

-

-

... More
WBT : at 83º F

-

-

-

... More
WB Approach : 2.7º C Maximum

-

-

-

... More
Hot water IN : 97.5 ºF

-

-

-

... More
Hot water OUT : 90ºF

-

-

-

... More
Water Flow Rate : 400 USGPM

-

-

-

... More
The price should include carriage, loading, unloading and cost of Civil Work including Foundation ( as recommended by the OEM )

-

-

-

... More
Make:- MIHIR, Bell, Paharpur

-

-

-

... More
Heat Rejection Capacity : 1,560,000 BTU/HR

3

-

476862

... More
AIR HANDLING UNITS - Ceiling Suspended

-

-

-

... More
Double skin Low height & Low Noise Ceiling Suspended AIR HANDLING UNITS made of 46+2mm thick Thermo-Accoustic panels (Thermal Break Profile) extruded aluminum profiles with 0.6mm thick pre-coated GI Outer Sheet, 0.6mm thick Plain GI intermediate sheet inside layer with polyurethene foam (PUF) CFC Free insulation of density 40+-2 kg/m3 factory injected between them by injection moulding machine & 0.6mm Plain GI Perforated Inner sheet , filter section with G4 filter,

-

-

-

... More
coil section with 6 row AHRI Certified chilled/Heating water coil, 22G SS304 drain pan with required thickness nitrile rubber insulation, factory mounted drain pump ,blower section with DIDW Aerofoil/ Backward/ Forward curved fans, Vibration isolators, Fan section access door, fire retardant canvass connection at fan outlet,Min IE-3 motor (TEFC type) and damper at the outlet of unit. All dampers shall be low leakage aluminum aerofoil design and suitable for manual / motorised operation. The selections for Ceiling mounted units shall be done considering the optimum Efficiency & Low Noise level with compact design of the units., complete as per specifications of following capacity:

-

-

-

... More
Make:- Zeco, Edgetech, Systemair, waves

-

-

-

... More
CFM SP TR

-

-

-

... More
2200 30 5.5

10

-

109581

... More
3400 30 8.5

9

-

149482

... More
4400 40 11

7

-

205343

... More
TFA ( Treated Fresh Air ) UNIT'S

-

-

-

... More
Supply, installation, testing & commissioning of weather proof double skin Floor Mounted TFA as per specifications & complete with the following: Chilled Water AHRI Certified Cooling coil section with 8 Row deep copper tubes & aluminum fins cooling coil as mentioned below extruded aluminum profiles with 0.8mm thick pre-coated GI Outer Sheet, 0.8mm thick Plain GI intermediate sheet inside layer with polyurethene foam (PUF) CFC Free insulation of density 40+-2 kg/m3 factory injected between them by injection moulding machine , filter section with G4 filter, , 22G SS304 drain pan with required thickness nitrile rubber insulation. Fan Section with BELT/DIRECT DRIVEN FAN, AMCA certified fan for performance & sound power level, high efficiency Backward Curved with fire retardant flexible connection at fan outlet. High efficiency 'IE3' squirrel cage induction motor suitable for 415±10% volts, 50±3%Hz, 3 phase AC supply. It shall be complete with V-Belt drive package. Motor's winding & winding insulation to be designed for any temp. rise. Fan & motor shall be mounted on a common base frame with motor sliding rails & complete base frame . Supporting arrangement comprising of supporting GI rods/Supports, GI channels, dash fastners,RCC Blocks & vibration isolators

-

-

-

... More
Make:- Zeco, Edgetech, Systemair, waves

-

-

-

... More
3000 CFM 15 Tr with 60mm SP

2

-

153569

... More
FAN COIL UNITS

-

-

-

... More
Supply,Installation , testing and commissioning of fan coil units of specified capacities and air flow as per the specifications , complete with auxillary drain pan

-

-

-

... More
Fan coil unit shall be supplied with approved make of factory fitted adequately sized insulated (with nitrile foam) two way motorized valves installations , insulated brass ball valves-one with Y strainer, and the other without Y strainer installations complete with room thermostat for fan speed control , associated conduiting and wiring between the thermostat , 2 - way valve .etc.

-

-

-

... More
Cost of fan coil unit shall be inclusive of approved make room thermostat (heating and cooling, with fan speed control), and associated MS conduiting and wiring etc.between the thermostat and two way valve , for a standard length of approximately 5-7 M per fan coil unit.

-

-

-

... More
Make:- Zeco, Edgetech, Systemair, waves

-

-

-

... More
2.0 TR nominal capacity suitable for both heating & cooling( 800 CFM)

2

-

19561

... More
WATER COOLED CASSETTE ACS

-

-

-

... More
Supply, installation, testing & commissioning of Water cooled Cassette Unit ( Four Way ) suitable for both heating/cooling with copper tube and aluminium finned cooling coil, low noise fan and motor with ON/OFF and 3 speed control and suitable for 1 phase, 230 + 6%V, 50 Hz electric supply, with cordless remote control, fabric filter, inbuilt drain pump, and decorative front grille. The Unit shall be complete with stainless steel duly insulated main and auxiliary drain pan. The unit shall be complete with electrical terminal strip, wiring in conduit upto thermostat box or any other advance technology. Unit shall have copper pipes for coil connection complete . The unit shall also have fresh air pocket provision. The front grill shall be 4 way type. The noise level at low speed shall be in the range of 38 to 42db & at high speed upto 45db. Noise levels are at a distance of 2M from the unit. (Note :Tonnage Variation allowed upto ±5%)

-

-

-

... More
Make:- Carriar, Trane, Dunham Bush

-

-

-

... More
2.0 Tr

1

-

45372

... More
3.0 Tr

1

-

49317

... More
4.0 Tr

19

-

56857

... More
EXPANSION TANK

-

-

-

... More
Supply, Installation ,Testing and commissioning of Open Mild Steel expansion tank as per the specifications.The Open vessel expansion tank shall be complete with all accessories so as to make it ready for installation and commissioning on site.The tank shall be insulated with the approved method of insulation, and shall be complete with water make-up connection and system .The expansion tank will be supplied,Non return Valve and interconnecting piping

-

-

-

... More
1000 Ltr . Open Expansion Tank duly insulated and with all accessories.

1

-

16994

... More
AIR SEPARATOR

-

-

-

... More
Supply,installation,testing and commissioning of Microbubble Air & Dirt Separator, with matching flanges, bolts, nuts & gasket, PN16 complete with flanged connection and as per the specifications as detailed earlier in the relevant section of specifications , and duly insulated with 50 mm thick TFF expanded polysterene and cladded with 26G aluminum sheet.

-

-

-

... More
Make:- Advance, Kirloskar, Honeywell

-

-

-

... More
150 mm Dia Air Separator , duly insulated.

1

-

60558

... More
CHILLED WATER PIPING

-

-

-

... More
Supplying, fixing, testing and commissioning of Mild Steel Pipes ( C- Class Heavy ) , IS 1239 marked of following sizes ( dia ) along with necessary clamps, vibration isolators and fittings such as bends,tees etc. including cutting, welding complete but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted / buried in ground including excavation , refilling and 4 mm thick anti corrosive tape lining etc. as per specification and as required complete in all respect.

-

-

-

... More
Make:- Jindal Hisar, TATA, SAIL

-

-

-

... More
150 mm

120

-

3064

... More
125 mm

40

-

2569

... More
100 mm

70

-

2076

40

-

1454

40

-

1176

80

-

926

160

-

665

500

-

570

40

-

451

... More
Supplying, laying/ fixing, testing and commissioning of Insulation with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. 50 mm thick for Pipe dia 25 mm to 100 mm and 75 mm thick for above 100 mm dia

-

-

-

... More
Make:- Beardsell, India Packaging, Lyoyd

-

-

-

... More
150 mm

120

-

1287

... More
125 mm

40

-

1106

... More
100 mm

70

-

748

40

-

589

40

-

507

80

-

418

160

-

336

500

-

297

40

-

251

... More
Providing and fixing in position Butterfly Valve with Cast Iron Body ( Powder Coated ), SS Disc, PN 16 Pressure rating of following dia complete.

-

-

-

... More
Make:- Advance, Kirloskar, Honeywell, Zoloto

-

-

-

... More
150 mm

2

-

4524

... More
125 mm

2

-

3916

... More
100 mm

14

-

3259

2

-

2471

2

-

2340

2

-

2161

... More
Providing and fixing Balancing Valve with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.

-

-

-

... More
Make:- Advance, Kirloskar, Honeywell, Zoloto

-

-

-

... More
125 mm

1

-

20175

... More
100 mm

3

-

14684

1

-

10135

1

-

8942

10

-

7748

9

-

5360

... More
Providing and fixing in position Y - Strainer with Cast Iron Body ( Powder Coated ), SS Filter Screen, PN 16 Pressure rating of following dia complete.

-

-

-

... More
Make:- Rapid Cool, SANT, Emerald

-

-

-

... More
100 mm

6

-

5445

10

-

2018

... More
Providing and fixing in position Dual Plate Check Valve ( Non Return Valve ) with Cast Iron Body ( Powder Coated ), SS Disc, PN 16 Pressure rating of following dia complete.

-

-

-

... More
Make:- Advance, Kirloskar, Honeywell, Zoloto

-

-

-

... More
100 mm

3

-

3808

... More
Extra for providing Insulation over valve / strainer including aluminium cladding.

-

-

-

... More
Above 80 mm dia

26

-

200

... More
Up to 80 mm dia

37

-

100

... More
Supply, Installation, Testing and Commissioning of following items

-

-

-

... More
Flow Switches ( Brass )

6

-

1532

... More
Auto Air Vent along with isolation valve

20

-

961

... More
Thermometer ( Stem Type )

12

-

318

... More
Pressure Gauge

12

-

970

... More
Supply, Installation, Testing & Commissioning of Insulated Two- way valves with modulating motors along with microprocessor based temperature controllers, Thermostat & sensors for AHUs.

-

-

-

... More
50 mm dia

10

-

26122

... More
40 mm dia

9

-

15278

... More
32 mm dia

27

-

13383

... More
25 mm dia

2

-

11667

... More
Brass Ball Valves with strainer

-

-

-

... More
Supply, Installation, Testing & Commissioning of Brass Ball Valve with Strainer

-

-

-

... More
40 mm dia

9

-

7102

... More
32 mm dia

9

-

4731

... More
25 mm dia

27

-

3071

... More
Brass Ball Valves without strainer

-

-

-

... More
Supply, Installation, Testing & Commissioning of Brass Ball Valve without Strainer

-

-

-

... More
40 mm dia

9

-

2359

... More
32 mm dia

9

-

1648

... More
25 mm dia

27

-

1008

... More
CONDENSOR WATER PIPING

-

-

-

... More
Supplying, fixing, testing and commissioning of Mild Steel Pipes , IS 1239 / IS 3589 marked of following sizes ( dia ) along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted / buried in ground including excavation , refilling and 4 mm thick anti corrosive tape lining etc. as per specification and as required complete in all respect.

-

-

-

... More
Make:- Jindal Hisar, TATA, SAIL

-

-

-

... More
250 mm x 6.35 mm

90

-

5961

... More
200 mm x 6.35 mm

12

-

4755

... More
150 mm ( Heavy - C Class)

40

-

3064

... More
Providing and fixing in position Butterfly Valve with Cast Iron Body ( Powder Coated ), SS Disc, PN 16 Pressure rating of following dia complete.

-

-

-

... More
Make:- Advance, Kirloskar, Honeywell, Zoloto

-

-

-

... More
250 MM DIA (Gear Box type)

6

-

16116

... More
200 MM DIA (Gear Box type)

2

-

10732

... More
150 MM DIA

18

-

4524

... More
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.

-

-

-

... More
Make:- Advance, Kirloskar, Honeywell, Zoloto

-

-

-

... More
150 MM DIA

6

-

26860

... More
Y- STRAINERS

-

-

-

... More
Providing and fixing in position Y - Strainer with Cast Iron Body ( Powder Coated ), SS Filter Screen, PN 16 Pressure rating of following dia complete.

-

-

-

... More
Make:- Rapid Cool, SANT, Emerald

-

-

-

... More
150 mm dia

3

-

11392

... More
POT- STRAINER

-

-

-

... More
Proiding and Fixing of Pot strainer with drain valve complete in all respect of following dia

-

-

-

... More
Make:- Rapid Cool, SANT, Emerald

-

-

-

... More
250 mm

1

-

31785

... More
Providing and fixing in position Dual Plate Check Valve ( Non Return Valve ) with Cast Iron Body ( Powder Coated ), SS Disc, PN 16 Pressure rating of following dia complete.

-

-

-

... More
Make:- Advance, Kirloskar, Honeywell, Zoloto

-

-

-

... More
150 MM DIA

3

-

6745

... More
Supply, Installation, Testing and Commissioning of following items

-

-

-

... More
Flow Switches ( Brass )

3

-

1532

... More
Auto Air Vent along with isolation valve

10

-

961

... More
Thermometer ( Stem Type )

6

-

318

... More
Pressure Gauge

6

-

841

... More
CONDENSATE DRAIN PIPE

-

-

-

... More
Providing and fixing and in position the following UPVC pipes for condensate drain duly insulated with minimum 6.0 mm 'O' Class Nirile rubber & duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the AHU/FCU units upto the main header in the shaft dor vertical risers, Including cost of chiesling ,holes,supports etc complete in all respect.

-

-

-

... More
Make:- Super, Supreme, Finolex

-

-

-

... More
65 mm dia

40

-

307

... More
50 mm dia

40

-

210

... More
40 mm dia

30

-

137

... More
32 mm dia

150

-

97

... More
25 mm dia

60

-

67

... More
GI DUCTING

-

-

-

... More
Supply and Installation of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required and shall also confirm to the BIS specifications. However only Collors/bends/plenums/suit pieces shall be fabricated at site. (Make of Sheet:- TATA, SAIL, JINDAL)

-

-

-

... More
Make:- Eco duct, Pioneer Airtech, Ductofab, Zeco

-

-

-

... More
0.63mm (24 gauge) GSS

650

-

749

... More
0.8mm (22 gauge) GSS

250

-

865

... More
1.0mm (20 gauge) GSS

30

-

981

... More
Supply, Fabrication, Installation and testing of Insulated Aluminium Flexible ducts TF quality in accordance with the approved shop floor drawings and specifications and shall also confirm to the BIS specifications

-

-

-

... More
Make:- UP Twiga, GPI, Pine aire, Caryaire

-

-

-

... More
150 mm Dia.

40

-

220

... More
200 mm Dia.

40

-

245

... More
Grilles/Diffusers

-

-

-

... More
Providing and fixing of Extruded aluminium supply and return air grilles/diffusers/ louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings.

-

-

-

... More
Make:- Caryaire, Systemair,Pine aire

-

-

-

... More
Supplying & fixing of powder coated extruded aluminium Supply Air Grills as per specifications

25

-

4158

... More
Supplying, fixing testing commissioning of Return/Supply air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

15

-

9984

... More
Supplying, fixing testing commissioning of aluminium Collor dampers as per specifications

20

-

4174

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes including control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.

-

-

-

... More
Make:- Caryaire, Systemair,Pine aire

-

-

-

... More
Fire damper

10

-

6227

... More
Actuator

26

-

9193

... More
Volume Control Dampers

-

-

-

... More
Make:- Caryaire, Systemair,Pine aire

-

-

-

... More
GI Volume control dampers for ducts

2

-

4312

... More
AI Volume control dampers for ducts

2

-

7036

... More
Fresh Air/Exhaust Air Louvers

-

-

-

... More
Supply and Installation of extruded aluminium louvres with frame bird screeen 50 mm pre-filter with frame, mounting arrangement etc. as per specifications and drawings.

-

-

-

... More
Make:- Caryaire, Systemair,Pine aire

-

-

-

... More
Fresh Air/Exhaust Louvers

2

-

5068

... More
Supply and Installation of double layer canvas connection with 1/2 hr. fire rating as per specification.

20

-

1893

... More
ACOUSTIC TREATMENT

-

-

-

... More
Supplying and fixing of Acoustic lining inside ducts/plenum using open cell nitrile rubber foam having microban anti-microbial/ anti fungal product protection and of 160-180 kg / m³ density as per ASTM D3575, class 1 ratingn As per BS476,PART-7, cut to required sizes and to be stuck to the inside of duct surfaces with adhesive as approved by the manufacturer. (Rubber based solvent). as per specifications

-

-

-

... More
Make:- Armacell, Kflex, BASF

-

-

-

... More
10mm thick sound board

90

-

816

... More
THERMAL INSULATION

-

-

-

... More
Supplying and fixing of external thermal insulation on ducts with closed cell elastomeric nitrile rubber insulation with density 40-60 Kg/m3 ,ANTI MICROBIAL/ANTI FUNGAL,Class 'O' material AS PER BS476 PART6&7 ASTM E 84. The product shall have temperature range of –40oC to 105oC.as per specifications and approved shop drawings

-

-

-

... More
13 mm thick with 2 layer Coating of 7mile cloth star bond insulation material .(For Open Duct)

30

-

392

... More
13 mm thick with Fiber Glass Cloth

850

-

523

... More
Make:- Armacell, Kflex, BASF

-

-

-

... More
ELECTRICAL PANELS

-

-

-

... More
Main Electrical Panel (CPRI Approved)

-

-

-

... More
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of following LT panels fabricated out of 14 guage CRCA sheet steel in cubical formationwith reinforecment of suitable size angle iron and channel T iron flats. All steel material used in the construction of panels shall be powder coated. A solid busbar shall be provided at the bottom/Top of the panel with two connecting eyes for termination. The boards shall be suitable for 415 volts, 50 Hz, 3 phase , 4 wire supply system. All the hardware used in the fabrication of the panel shall be galvanized with zinc passivation. The panel shall be compartmentalized to accommodate one feeder in each compartment. A vertcal cable alley of suitable width shall be provided to serve on or two vertical feeder sections. Also the opening between the busbar chamber and the feeder section shall be shrouded with bakelite / hylam sheet with min.3 mm thickness., The panel manufacturer shall have min 70 KA CPRI Certification

-

-

-

... More
The panel drawing shall be approved before taking up the fabrication and Shall have compitable BMS for future requirment.

-

-

-

... More
In All panels Each starter should have remote control compatibilty and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire. All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing control modules.

-

-

-

... More
Main A.C. Panel

-

-

-

... More
Incomer for Transformer

-

-

-

... More
1 No. 850 - 1000 Amps ACB 4 Pole incoming (EDO) 65KA with S/c, O/L & other protections

-

-

-

... More
1 no. Multifunction meter (equivalent EM64XX) with CTs as per requirment

-

-

-

... More
3 Nos. phase indicating lamps

-

-

-

... More
Bus Bar Aluminium

-

-

-

... More
1 No. 1000 - 1200 Amps aluminium conductor bus bar duly sleeved

-

-

-

... More
Outgoing

-

-

-

... More
3 No. 250 Amps TP+NL MCCB with adujustable release 50 KA with ROM & Spreader links S/c, O/L & other protections outgoing for chillers.

-

-

-

... More
2 Nos. 250 Amps TP+NL MCCB with adustable release 50 KA with ROM & Spreader links S/c, O/L & other protections for 100 KW Hot water generator (interlocking electrically done to operate either chillers or HWG at a time)

-

-

-

... More
3 Nos. 63 Amps MCCB 25KA TP+NL with ROM & Links outgoing for chiller water pumps with upto 15 KW Star Delta starter (3 Working & 0 Standby)

-

-

-

... More
3 Nos. 100 Amps MCCB 25KA TP+NL with ROM & Links outgoing for condenser water pumps with upto 25 KW Star Delta starter (3 Working & 0 Standby)

-

-

-

... More
3 No. 63 Amps 25 KA MCCB with ROM & Links outgoing for Cooling Tower motor (1 DOL starters on each cooling tower of upto 7.5 KW each with incomer MCB TP seprate for each starter)

-

-

-

... More
1 Nos. 250 Amps 36 KA MCCB TP+NL outgoing for sub Panel with ROM & Links

-

-

-

... More
1 Nos. 125 Amps 36 KA MCCB TP+NL outgoing for sub Panels with ROM & Links as a spare

-

-

-

... More
All starter shall have following accessories :

-

-

-

... More
1 No. overload relay

-

-

-

... More
1 No. Ammeter with CTs.

-

-

-

... More
1 No. single phase preventer

-

-

-

... More
2 Nos. ON/OFF indicating lights

-

-

-

... More
2 Nos. ON/OFF push buttons

-

-

-

... More
Hardware (PVC Channels/MCB Channels/Fibre- Glass/Gaskits/Sleeves/nuts/Bolts/washers/cooling fans/etc)

-

-

-

... More
Make:- ABB, Siemens, L&T, Unitech-Power system, Vrindavan Electicals, KEPL

-

-

-

... More
Complete Wiring inclusive of thimbles,etc

1

-

799071

... More
Unloading at site, RCC foundation ,placement of Panel on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Panel.

-

-

-

... More
Sub Distribution Panel For AHUs

-

-

-

... More
SITC of panel board made of 1.6mm for non load bearing /2.0 mm thick steel sheet for non load bearing sections duly powder coated complete with Metering, indicating lights, CTS contactors, A/M Switch for remote controls operation complete as per specifications and drawings and as required.

-

-

-

... More
Incomer

-

-

-

... More
1 Nos. 250 Amps 36 KA MCCB TP+NL with ROM & Links

-

-

-

... More
1 No. 300 Amps aluminium conductor bus bar duly sleeved

-

-

-

... More
1 no. Multifunction meter with CTs as per requirment

-

-

-

... More
3 Nos. phase indicating lamps

-

-

-

... More
Outgoing

-

-

-

... More
32 Nos(28 W + 4 Spare) MPCB suitable for 1.5 to 3.7 KW DOL Starter for AHU having contactors, LED indicators for on/off , O/L Relay, SPP, etc. as per coordination chart

-

-

-

... More
2 nos MCB TPN 32 Amps 'C" Curve Spare

-

-

-

... More
Make:- ABB, Siemens, L&T, Unitech-Power system, Vrindavan Electicals, KEPL

-

-

-

... More
Complete Wiring inclusive of thimbles,etc

1

-

308280

... More
TPN MCB Boxs

-

-

-

... More
SITC of Isolator TPN MCB Type 6-16 Amps or as per rating of the AHU Motor with box along with all accessories etc. complete in all respect. Make:- L&T, GE Power controls, Siemens

28

-

2648

... More
BASEMENT VENTILATION

-

-

-

... More
CEILING MOUNTED JET VENT FAN

-

-

-

... More
Supply, installing, testing and commissioning of Ductless Ventilation / Axial type Jet fans as per attached specifications for normal ventilation & smoke extraction . Each fan shall be complete with dual speed motor and die cast aluminium impeller. Casing shall be made of Hot dipped Galvanized steel. The Motor shall be run on the electrical power suitable for 415V/3Ph/ 50Hz.

-

-

-

... More
The complete fan assembly with its casing, impeller and motor ( not only motor or one of the item ) shall be sourced from one manufacturer and certified and tested as per EN12101-3-:2015/Indian Standared as per NBCC, Min .250 degree for 2 Hrs operation.Silencer lenght should be 2d+ 2d . Each Jet Fan assembly shall connect to a composite PLC Panel controlled by CO Sensors / Fire Alarm System

-

-

-

... More
Make:- Systemair, Flaktwood, LTI

-

-

-

... More
Capacity- 5400/2700 CMH, 31N Thrust , 315 mm Dia or suitable at site

4

-

39891

... More
LONG CASED TUBE AXIAL FAN

-

-

-

... More
Supply, installation, testing and commissioning of Direct drive Long cased Tube Axial fans complete with Hot dipped Galvanised Steel /Pre Galaavanised Steel Casing with spun flanges, adjustable pitch die cast aluminium impeller (Hub and Aerofoil blades) and IE3 motors. Casing position shall be as per the job requirement and shall be marked on the fan assembly.The complete fan assembly with its casing, impeller and motor ( not only motor or one of the item ) shall be sourced from one manufacturer and degree for 2 Hrs operation.The complete assembly must have certificate of consistency of performance by BSI and must bear CE marking.MotorShall be suitable for 415 volts ± 10%, 50Hz ± 3 %, three phase A.C complete with starter having overload & single phase protection, support, mountings, vibration isolators, fire retardant flexible canvass connector 150 mm deep (Inlet & Outlet as required), bird screen (Inlet & Outlet as required) including cutting of Glass/wall etc. & of following capacity

-

-

-

... More
Make:- Systemair, Flaktwood, LTI

-

-

-

... More
Capacity 6600cfm @ 25 mm Static (for normal + Emergency exhaust mode) Fans should be suitable for emergency mode operation (250 Deg / 2 Hrs)

4

-

52591

... More
LONG CASED TUBE AXIAL FAN

-

-

-

... More
Supply, installation, testing and commissioning of Direct drive Tube Axial fans complete with Hot dipped Galvanised Steel /Pre Galaavanised Casing with spun flanges, adjustable pitch die cast aluminium impeller (Hub and Aerofoil blades) and IE3 motors. Casing position shall be as per the job requirement and shall be marked on the fan assembly.The complete fan assembly with its casing, impeller and motor ( not only motor or one of the item ) shall be sourced from one manufacturer.MotorShall be suitable for 415 volts ± 10%, 50Hz ± 3 %, three phase A.C complete with starter having overload & single phase protection, support, mountings, vibration isolators, fire retardant flexible canvass connector 150 mm deep (Inlet & Outlet as required), bird screen (Inlet & Outlet as required) including cutting of Glass/wall etc & of following capacity

-

-

-

... More
Make:- Systemair, Flaktwood, LTI

-

-

-

... More
Capacity 6600 cfm @ 25 mm Static (for normal mode) Fans should be suitable for normal temp

1

-

49147

... More
CO SENSORS

-

-

-

... More
Supply, installation, testing and commissioning of CO Sensors (0 - 250 PPM detection Range) complete with hanging arrangments. Make:- Honeywell, Siemens, Notifier

4

-

13636

... More
Control Panel for Ventilation PLC Based

-

-

-

... More
Supply,Installation,Testing and Commissioning Contol Panel Made out of approved make sheet having thickness 2.0 mm for load bearing surfaces & 1.6 mm Non bearing surfaces duly processsed powder coated having Siemens grey colour as per following specifications complete in all respect

-

-

-

... More
SITC of Electrical cum PLC Based Panel for Basement with MCB feeders with starters for 6 nos dual speed 3 phase Jet Fan fans of 1.7/0.34 kW each,MCCB feeders with starters for 4nos. Exhaust fans single speed of upto 10Kw & 1 No Fresh Air Fan of upto 8 kw(optional). controlled by nos- upto 6 NO CO Sensors, with suitable incomer MCCB, VIF Meter on mains & on each feeder herein referred to as each O/G section to Jet fans as well as Exhaust with Amperemeter Digital, aluminium bus bar as per requirment, PLC logic controller with necessary internal control wiring etc. Make:- ABB, Siemens, L&T, Unitech-Power system, Vrindavan Electicals, KEPL

1

-

274237

... More
CFD Analysis

-

-

-

... More
Preparation and approval of CFD ( Computational Fluid Dynamics ) Analysis in Basement Area .CFD analysis to decide the correct location and quantity of jet fans. CFD analysis will be carried out for both normal and fire mode ventilation situation considering 6/12 ACPH, airflow strategy and control strategy to confirm the operation logic. CFD analysis will model all the cars, car parking bays, beams, structures, columns, voids, shafts, ramps, proposed fresh air route, fresh air shaft, exhaust air shaft and preliminary location of jet fans shown in the drawing. CFD output will give complete simulation of ventilation scheme not limited to velocity profile, temperature profile, smoke temp and movement profile, CO level profile, air movement profile. The number of repeat simulations shall be carried out until satisfactory results are achieved.

1

-

40190

... More
Make:- ABB, Siemens, L&T, Unitech-Power system, Vrindavan Electicals, KEPL

-

-

-

... More
Power Cabling and Earthing

-

-

-

... More
Supply, installation, testing & commisioning of Aluminum conductor cables PVC sheathed, armoured cables of 1.1 KV grade with termination glands and GI earthing, identification tags, clamps and saddles etc.

-

-

-

... More
Make:- Finolex, L&T, Havells, Polycab

-

-

-

... More
3.5Cx185 Sqmm

50

-

1176

... More
3.5Cx150 Sqmm

40

-

929

... More
4.0Cx16 Sqmm

60

-

189

... More
4.0Cx10 Sqmm

30

-

159

... More
4.0Cx 06 Sqmm

180

-

135

... More
4.0Cx04 Sqmm

100

-

115

... More
4Cx2.5 Sqmm (Cu Conductor)

1500

-

227

... More
Control Cabling - COPPER

-

-

-

... More
Supply, installation, testing & commisioning of Copper conductor , PVC insulated, PVC sheathed armoured cable of 1.1 KV grade (Which is Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers and AHU to Control Consol Panel

-

-

-

... More
Make:- Finolex, L&T, Havells, Polycab

-

-

-

... More
3C x 1 Sqmm

100

-

60

... More
2C x 1 Sqmm

50

-

43

... More
Supply, Laying, testing and commissioning of FRLS XLPE armoured cables for Electrical Power and controls from MCC/LSCP/PDB to respective Equipments with earthing, clamped on surface or on cable trays, structural supports and cable supports provided. The scope includes End Termination of cables with Double Compression type Brass Cable Glands and Copper Lugs, clamping of cables by ready made G.I. spacers, saddles or clamps fabricated out of GI. strip 3 mm thick, treasing and Clamping of Cable on cable tray or surface, supply of all clamping materials and hardware etc., providing cable tags made out of aluminium/PVC laminated strip and 75x20 mm in size with cable number and size punched on it. Cable tags shall be tied to cables at every 20 meter interval and at both the ends. MS Powder Coated Junction Boxes with Bolted type terminals of suitabel size shall be provided near all Fan Motors for termination of armoured cables.

-

-

-

... More
Make:- Finolex, L&T, Havells, Polycab

-

-

-

... More
4C x 6 Sqmm Copper Cable ( For Fire Exhaust Fans)

200

-

415

... More
4C x 1.5 Sqmm Copper Cable ( For Jet Fans )

200

-

107

... More
Supply & laying of XLPE armoured copper conductor twisted shielded control cables 3C X 1.5 Sq.mm twisted shielded cables for CO sensors.

180

-

105

... More
CABLE TRAY

-

-

-

... More
Supplying and installing following size of perforated G.I. cable trays, 1.6 mm thick , G.I. bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with suitable suspenders including G.I. bolts & nuts, painting of suspenders etc. complete as required.

-

-

-

... More
50mm x 100 mm x 50mm.

50

-

224

... More
50mm x 150 mm x 50mm.

50

-

276

... More
50mm x 200 mm x 50mm.

50

-

328

... More
50mm x 300 mm x 50mm.

80

-

432

... More
50mm x 450 mm x 50mm.

20

-

587

... More
Under Deck Insulation

-

-

-

... More
Providing & Fixing Underdeck Insulation with 50 mm thick TF Quality EPS of Density 20 Kg/M3 fixed to slab with good quality Black CPRX Compound. 28G wirenet shall be tightened arround insulation so as avoid any kind of sagging, Ends of net shall be overlapping at least 25mm. Overlaps shall be screwed with galvanized screws to avoid rusting.

700

-

440

... More
Make:- Beardsell, Lyoyd

-

-

-

... More
EARTHING

-

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

2

-

11794

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required

50

-

1009

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

80

-

206

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recessfor loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.

600

-

37

... More
PART B - Operation and Maintenance

-

-

-

... More
Comprehensive Maintenance & Operation Charges Minimum 8 hours x 6 Days, for first 2 years during defect liabilty period from the date of handing over the system

-

-

-

... More
Operation & Maintenance charges for Central AC system including routine and Comprehensive maintenance with parts including consumables such as gas, oil, filters and break down maintenance of high & low side of the air conditioning plant comprising of all the machinery Including deployment of 01 No AC Mech. cum Operator & 1 No Helper in single shift of Min 8.0 hrs or As per minimum requirement by Department

-

-

-

... More
1st Year ( Operation + Free of cost Comprehensive maintenance with parts) (46079 x 12 = 552948/-)

1

-

552948

... More
2nd Year ( Operation + Free of cost Comprehensive maintenance with parts) (46079 x 12 = 552948/- + 7% = 591654)

1

-

591654

... More
Sub Total

-

-

-

... More
Comprehensive Maintenance & Operation Charges (Min.8 hrs x 6 days) after 2 years defect liabilty period from the date of handing over the system

-

-

-

... More
Operation & Maintenance charges for Central AC system including routine and Comprehensive maintenance with parts including consumables such as gas, oil, filters and break down maintenance of high & low side of the air conditioning plant comprising of all the machinery Including deployment of 01 No AC Mech. cum Operator & 1 No Helper in single shift of Min 8.0 hrs or As per minimum requirement by Department

-

-

-

... More
3rd Year ( Operation + 1 % of the capital cost for Comprehensive maintenance with parts) ( 591654+ 7% = 633070) + (1% of Capital Cost i.e. Rs. 25937938 = 259379) (633070+259379 = 892449)

1

-

892449

... More
4th Year 7 % on Rs. 892449 = Total Rs.954920/-

1

-

954920

... More
5th Year 7 % on Rs.954920 = Total Rs.1021765/-

1

-

1021764

... More
6th Year 7 % on Rs. 1021765 = Total Rs.1093288/-

1

-

1093287

... More
7th Year 7 % on Rs. 1093288 = Total Rs.1169819/-

1

-

1169817



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.