Chandigarh Administration Tender

View complete overview of Chandigarh Chandigarh Administration Tender

Chandigarh Administration Tender

Works
Civil And Construction
Building Construction
Consultancy Services
Civil And Architectural Services
Eprocure
Opening Date25 Jan 2025
Closing Soon31 Jan 2025
Tender Amount₹ 3,43,01,117 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
EXTENSION OF KURUKSHETRA AND HIMALAYA BOYS HOSTEL MESS AT PUNJAB ENGINEERING COLLEGE, SECTOR 12, CHANDIGARH (COMPOSITE WORK).
EXTENSION OF KURUKSHETRA AND HIMALAYA BOYS HOSTEL MESS AT PUNJAB ENGINEERING COLLEGE, SECTOR 12, CHANDIGARH (COMPOSITE WORK).
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR 2.27)

144.28

2066

298141.63

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources: 10 graded stone aggregate 40 mm nominal size derived from natural sources). (DSR 4.1.10 )

37.64

6342

238735.46

... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. (DSR 4.13)

57.66

142

8199.25

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (DSR 4.17)

74.03

729

53973.05

... More
Centering and shuttering including strutting, propping etc. and removal of form for

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete (DSR 5.9.1)

37.36

381

14255.08

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR 5.9.2)

97.21

819

79687.9

... More
Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3)

1418.99

902

1280226.97

... More
Shelves (Cast in situ) (DSR 5.9.4)

8.91

902

8038.69

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR 5.9.5)

449.4

716

322004.09

... More
Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 5.9.6)

472.81

935

442238.11

... More
Stairs, (excluding landings) except spiral-staircases (DSR 5.9.7)

21.48

744

15987.56

... More
Edges of slabs and breaks in floors and walls (DSR )

-

-

-

... More
Under 20 cm wide (DSR 5.9.16.1)

703.63

202

142780.6

... More
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).

-

-

-

... More
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) (DSR 5.11.1)

934.17

373

349304.85

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.

-

-

-

... More
Thermo-Mechanically Treated bars of grade Fe-500 D or more. (DSR 5.22.6)

6996.13

104

734173.88

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.

-

-

-

... More
Thermo-Mechanically Treated bars of grade Fe-500 D or more. (DSR 5.22A.6)

42131.36

104

4421264.92

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
All works upto plinth level

-

-

-

... More
Concrete of M30 grade with minimum cement content of 350 kg /cum (DSR 5.33.1.2)

102.14

9395

959605.3

... More
All works above plinth level upto floor V level

-

-

-

... More
Concrete of M30 grade with minimum cement content of 350 kg /cum (DSR 5.33.2.2)

306.04

9741

2981147.88

... More
Add for using extra cement in the items of design mix over and above the specified cement content therein. (DSR 5.35)

204.09

713

145659.03

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:

-

-

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2 )

56.33

6939

390912.17

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :

-

-

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2)

255.8

8860

2266411.02

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.

-

-

-

... More
Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2)

37.76

1093

41289.05

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (DSR 6.15)

37.76

101

3850.39

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.

-

-

-

... More
Granite stone slab all colour and texture except black, Cherry/Ruby red

-

-

-

... More
Area of slab over 0.50 sqm (DSR 8.2.3.2)

10.22

3744

38271.75

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.

-

-

-

... More
Granite work (DSR 8.3.2)

16.46

497

8183.09

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR 8.5)

12

952

11427.36

... More
Providing and fixing machine cut, mirror/ eggshell polished , Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern (if required with marble stone slab pieces of different shapes, sizes & texture but of even thickness) on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.

-

-

-

... More
18 mm thick Italian Marble stone slab,Perlato, Rosso verona,Fire Red or Dark Emperadore etc. (DSR 8.11.1)

36.9

10133

373929.84

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR 8.31)

168.99

1233

208486.34

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:

-

-

-

... More
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.1)

21.93

2328

51054.14

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). (DSR 9.23)

21.93

449

9865.65

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :

-

-

-

... More
250 x 16 mm (DSR 9.96.2)

12

253

3042.72

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :

-

-

-

... More
300x 10mm (DSR 9.97.1)

12

126

1519.08

... More
250 x 10 mm (DSR 9.97.2)

12

112

1344.48

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :

-

-

-

... More
125 mm (DSR 9.100.1)

24

64

1547.04

... More
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.

-

-

-

... More
1.0 mm thick (DSR 9.127.2)

43.87

873

38301.58

... More
Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds

-

-

-

... More
Two track two panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on every panel along with multi-point locking system, adjustable nylon rollers with SS 304 body.

-

-

-

... More
Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre). (DSR 9.147.B1.1)

17.43

7887

137477.9

... More
Three track three panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body.

-

-

-

... More
Using R3 series with frame (98 mm & above) x (40 mm & above) & sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre). (DSR 9.147.B4.1)

233.36

8063

1881651.69

... More
Providing and fixing stainless steel (SS-304 grade) friction hinges to the side/top hung uPVC windows, of approved quality, with necessary stainless steel screws etc. as per direction of Engineer-in-charge. (200X19X1.9 MM) (DSR 9.148.1)

80

371

29680

... More
Providing and fixing steel (white power coated) crescent lock for uPVC sliding window/ door with necessary screws etc. complete (DSR 9.153)

38

192

7332.1

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR 10.1)

5568.37

114

635796.49

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) (DSR 10.28)

227.5

751

170977.63

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :

-

-

-

... More
25 mm thick (DSR 11.26.1)

1387.52

1895

2630252.29

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR 11.27)

27.21

2291

62341.38

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.

-

-

-

... More
Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent (DSR 11.56.1)

249.82

4360

1089290.15

... More
Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red (DSR 11.56.2)

6.26

2988

18705.69

... More
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. :

-

-

-

... More
150 mm diameter (DSR 12.38.2)

103

384

39646.76

... More
Providing lead caulked joints to sand cast iron rain water pipes and fittings:

-

-

-

... More
150 mm dia Pipe (DSR 12.39.2)

103

776

79974.35

... More
Providing, fixing and embedding sand cast iron accessories for rain water pipes in the masonry surrounded with 12 mm thick cement mortar of the same mix, as that of masonry (lead caulking will be paid for separately):

-

-

-

... More
Sand cast iron plain shoes :

-

-

-

... More
150 mm diameter (DSR 12.40.1.1)

4

498

1992.32

... More
Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :

-

-

-

... More
GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. (DSR 12.54.2)

39.1

2291

89580.84

... More
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. (DSR 12.55)

39.12

1657

64858.61

... More
12 mm cement plaster of mix :

-

-

-

... More
1:4 (1 cement: 4 coarse sand) (DSR 13.4.1)

1299.66

347

451891.78

... More
15 mm cement plaster on rough side of single or half brick wall of mix:

-

-

-

... More
1:6 (1 cement: 6 coarse sand) (DSR 13.5.2)

1057.38

384

406752.94

... More
6 mm cement plaster of mix :

-

-

-

... More
1:3 (1 cement : 3 fine sand) (DSR 13.16.1)

985.96

292

288235.55

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. (DSR 13.26)

3342.99

255

854501.67

... More
White washing with lime to give an even shade :

-

-

-

... More
New work (three or more coats) (DSR 13.37.1)

985.96

38

37466.48

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80)

3342.99

151

507599.6

... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.

-

-

-

... More
Two coats (DSR 13.83.2)

2357.03

138

327485.75

... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.

-

-

-

... More
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre (DSR 13.85.3)

2357.03

71

169588.31

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.

-

-

-

... More
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) (DSR 15.2.1)

64.18

2368

152012.26

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR 15.3)

8.18

3455

28264.93

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.

-

-

-

... More
In cement mortar (DSR 15.7.4)

40.22

2004

80623.81

... More
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :

-

-

-

... More
Of area 3 sq. metres and below (DSR 15.13.1)

30

139

4188.9

... More
Of area beyond 3 sq. metres (DSR 15.13.2)

4

183

735.2

... More
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. (DSR 15.18)

2226.37

5

12245.04

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.

-

-

-

... More
For thickness of tiles 10 mm to 25 mm (DSR 15.23.1)

1140.61

71

81462.37

... More
Demolishing mud phaska in terracing and disposal of material within 50 metres lead. (DSR 15.27)

65.17

889

57975.88

... More
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:

-

-

-

... More
G.S. Sheet (DSR 15.28.1)

103.81

160

16661.51

... More
Asbestos Cement sheet (DSR 15.28.2)

182.73

75

13743.12

... More
Dismantling expanded metal or I.R.C. fabrics with necessary battens and beading including stacking the serviceable material within 50 metres lead. (DSR 15.38)

68.73

73

5068.84

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR 15.56)

933.65

53

49642.17

... More
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. (DSR 15.57)

15.39

54

843.83

... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR 15.60)

20

256

5136.4

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:

-

-

-

... More
With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (DSR 22.7.1)

200.62

1639

328840.25

... More
Providing and fixing on wall face 150mm dia H.C.I rain water pipe confirming to IS:1729 Type A, as directed by Engineer-in-charge

-

-

-

... More
150 mm dia (NS)

152

2297

349144

... More
Providing and fixing ½'' thick Brick clading GRC wall tiles size 9''x3'' (thickness to be specified by the manufacturer), of approved make, any size as approved by Engineer-in-Charge, on outer wall, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade up to all height complete. (NS)

834.69

1860

1552815.54

... More
Providing and fixing Zinc coated pressed steel door frames of size 5x2.5" confirming to IS: 4351 of 1.60mm thickness mild steel sheet of Zinc coated including the cost of of cement concret 1:2:4 to be filled in hold fasts ,hinges,jamb,bead and if required angle thrashold of mild steel angle of section 50x25mm,or base ties of 1.6mm pressed mild steel welded or rigidly fixed togather by mechanical mean,including M.S. pressed butt hinges 2.5mm thick of Zinc coated with mortar guards,lock strike-plate and shock absorber as specified and applaying a coat of approved steel primer after pre-treatment of the surface as directed by the Engineer-in-charge and as per architectural drawings. (NS)

63.4

579

36751.71

... More
Providing & fixing on 5 mm thick roofing stone metal coated steel roofing shingles sheet or equivalent of approved size, color and as per approved pattern fixed with tappered nails/screws after applying a coat of bitumen primer complete as per direction and entire satisfaction of Engineer - in - Charge. (NS)

402.92

3186

1283904.58

... More
Providing & fixing on 5 mm thick roofing stone coated steel ridge sheet or equivalent of approved size, color and as per approved pattern fixed with tappered nails/screws after applying a coat of bitumen primer complete as per direction and entire satisfaction of Engineer - in - Charge. (NS)

48

1705

81864

... More
1) DSR Item No.1.3.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group-C

240

1928

462720

... More
2) DSR Item No.1.4 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

2

2070

4140

... More
3) DSR Item No.1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

16

498

7968

... More
4) DSR Item No.1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

24

612

14688

... More
5) DSR Item No.1.27 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.

-

-

-

... More
6 Module (200mmX75mm)

10

420

4200

... More
6) DSR Item No. 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 amp. Switch

20

108

2160

... More
3 pin 5/6 amp. Socket

20

127

2540

... More
Telephone socket outlet

4

155

620

... More
TV antenna socket outlet

10

155

1550

... More
7) DSR Item No.1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
3 x 1.5 sq. mm

1080

99

106920

... More
3 x 2.5 sq. mm

800

143

114400

... More
8) DSR Item No.1.20 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

500

233

116500

1200

268

321600

... More
9) DSR Item No.1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire

20

788

15760

... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire

45

1050

47250

... More
10) DSR Item No. 2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

-

-

-

... More
4 way (4 + 12), Double door

2

7850

15700

... More
8 way (4 + 24), Double door

2

10622

21244

... More
11) DSR ITEM NO.2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

72

267

19224

... More
Triple pole and neutral

4

1283

5132

... More
12) DSR item No. 5.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.

4

5610

22440

... More
13) DSR item No. 5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

40

300

12000

... More
14) DSR item No. 10.18 (Civil) Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

52

190

9916.4

... More
15) DSR Item No 14.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal)

200

258

51600

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

110

385

42350

... More
16) DSR Item No 1.18 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
1 Pair

100

32

3200

... More
17) DSR Item No 1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

200

49

9800

... More
18) DSR item No.19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, 48” ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

4

2853

11412

... More
19) Supply, Installation, Testing and Commissioning of 1400 mm sweep (maximum wattage upto 35W), BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 7.42, Air delivery minimum 245 CMM, 300 RPM (tolerance as per IS : 374-2019), THD less than 10%, OEM designed electronic regulator unit for speed control in various steps as per BIS (proof shall be submitted alongwith fan before installation at site) and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. The fan should be of Havells/ Atomberg/ Bajaj/ Crompton make only.

48

3820

183360

... More
20) S/E of fresh air fan high speed motor with copper wound 10” sweep with louver and plastic body complete with speed motor, blades, epoxy powder coated of Havells make Ventilator DX white/ Orient make ventilator/ Crompton make Brisk Air/ Usha Crisp air/ Bajaj Supreme maxima DXI only. The cost includes the connection with adjacent light points and installed on wall with suitable arrangement by providing frame of required size made out 6mm thick water proof plywood to be installed with suitable size rag bolts, nuts after making suitable size hole in the wall if required at site to the entire satisfaction of Engineer-in-charge.

4

2170

8680

... More
21) Supply, carriage, erection, testing & commissioning of 1200 mm linear surface light with LED CCT of 5700-6500 K light source with light fixture to have a maximum of total system wattage of 20/22 W with total at source lumen of 2000 lumen & 50000 hours with IP 67, Beam angel of fixture to be surfaced with housing which is to be embedded in concrete casting end to end. Total arrangements to be flushed with concrete riser. Light fixtures to have possibility of seamless connections. Light fixture to be supplied with housing and mounting clip for concrete insertion size with variation ± 15% [width(visible on surface) x Height x Length] (43x80x1200mm). The job includes cost of labour making connection and other petty material required to complete the job to the entire satisfaction of Engineer in charge of the work. The fitting should be of Wipro/ Philips/Bajaj/ Havells make only.

268

6890

1846520

... More
22) S/E of Surface type LED square down lighter 12 Watt with cool white light output with open integral driver. The down lighter should be of Philips/ Wipro/ Bajaj/ Surya/Twinkle make only. The fitting shall be installed in the existing false ceiling with suitable arrangements. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. As required to complete the same to the entire satisfaction of EIC.

-

-

-

... More
Specification of LED fittings

-

-

-

... More
Wattage of LED fittings - As per following parameter.

-

-

-

... More
Total lumens of the LED fittings - Minimum 1200 lumen

-

-

-

... More
Body of fittings - Die cast housing made of aluminum & white power coated finishing

-

-

-

... More
Operating voltage - 140 V to 260 V, AC supply or better.

-

-

-

... More
Input frequency - 50 Hz + 1 Hz

-

-

-

... More
Power factor - Minimum 0.9

-

-

-

... More
Luminaire efficacy - 100 lm/w

-

-

-

... More
Color rendering index - CRI shall be 80 (minimum)

-

-

-

... More
Working/ operating temperature - 00 to + 450c or better

-

-

-

... More
Color temperature - 57000K + 10%

-

-

-

... More
Electronic Driver

-

-

-

... More
Drive current (LED) - As per OEM.

-

-

-

... More
Operating voltage - 160 V to 240 V AC supply or better

-

-

-

... More
Type of driver - Constant current output driver

-

-

-

... More
THD - Less than 10%

-

-

-

... More
Surge Protection - 2.5 KV minimum

-

-

-

... More
Efficiency Driver - 85%

-

-

-

... More
Protection - Shall have under voltage and over voltage protection.

-

-

-

... More
Warranty of LED fittings including LED driver - 2 years against manufacturing defect.

-

-

-

... More
Fixture - Should comply with LM79 test from Govt. Authorized Lab/ NABL/ UL Lab.

-

-

-

... More
LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.

-

-

-

... More
Life of LED - 50000 burning hours at 70% lumen maintenance

112

1050

117600

... More
23) DSR Item No. 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
63/100 A,30KA,FPMCCB

5

8071

40355

... More
24) Supply and Laying of following XLPE insulated and PVC sheathed, armoured, aluminium conductor cable of 1.1KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing DWC/RCC/HUME pipe as required at site. The job include the cost of making connections with suitable size of Al. Lugs/thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. The cable should be of Polycab / Havells / Finolex / RR Kabel / KEI / RPG / Universal make only.

-

-

-

... More
Size 50 Sq.mm 3.5 core PVC Al. Arm. Cond. Cable

210

560

117600

... More
Size 150 Sq.mm 3.5 core PVC Al. Arm. Cond. Cable

120

1332

159840

... More
25) Fabrication, Supplying, Installation, Testing and Commissioning of outdoor type double door Electric Control Panel of cubical construction, floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade, having suitable capacity TPN Aluminum bus bars, DMC/ SMC bus bar supports, base frame of MS channel 100mm x 50mm x 6mm size, having switchgears and accessories , internal wiring with 2.5 sq.mm PVC insulated single core cable, common copper earth bar of size 25 x 5 mm over the entire width of panel and 2 nos. earth studs, cable entry from the top & bottom, cable gland plates, numbering, labeling etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply with protection class IP 54 as required. The job includes the cost of accessories, interconnection with solid connection, carriage and installation of cubical panel at site to the entire satisfaction of Engineer in charge. The outdoor type double door Electric Control Panel should have provision of following switchgear and accessories:-

-

-

-

... More
INCOMING

-

-

-

... More
250 Amps. 36 KA, four Pole, Thermal magnetic release , MCCB (Ics = Icu at 415 V) with O/L, S/C & built-in earth fault protection :- 1 No.

-

-

-

... More
Changeover switch 250 Amps. 415 V, four Pole:- 1 No.

-

-

-

... More
BUS BAR

-

-

-

... More
Supply and erection of TPN Aluminum bus bars (having 100% Neutral) of minimum of 200 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminum bus shall be 1 Amp/sq. mm.- 1 Set.

-

-

-

... More
OUTGOING

-

-

-

... More
100 Amps. 36 KA, four Pole, Thermal magnetic release , MCCB (Ics = Icu at 415 V) with O/L, S/C & built-in earth fault protection :- 2 Nos.

1

134460

134460

... More
26) Supply & erection of 4 way load bank enclosure double door with cable alley & provision of 100A 36 KA MCCB as incomer & 4 Nos.100 A 36 KA MCCB as outgoing with provision din bar, earthing, internal 200 A BBC terminal & connection IP 43 etc. complete in all respect on surface/recess as required. The load bank enclosure should be of L & T/ Havells make only. The load bank & MCCBs both should be same make. The job includes all labour & petty material required to complete the job to the entire satisfaction of EIC.

1

62300

62300



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.