Chandigarh Administration Tender

View complete overview of Chandigarh Chandigarh Administration Tender

Chandigarh Administration Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date26 Feb 2024
Closing Date2 Mar 2024
Tender Amount₹ 1,99,482 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
RENOVATION OF HOUSE NO. 509, (TYPE 6) SECTOR 16, CHANDIGARH. (IBM SCHEME NO. W4 2024 22768).
RENOVATION OF HOUSE NO. 509, (TYPE 6) SECTOR 16, CHANDIGARH. (IBM SCHEME NO. W4 2024 22768).
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
DSR Item No. 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required.

-

-

-

... More
Group B.

10

6840

684

... More
DSR Item No. 1.16 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.

2

1920

960

... More
DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
3 x 1.5 sq. mm

80

8160

102

... More
3 x 2.5 sq. mm

60

8820

147

... More
3 x 4 sq. mm

40

8840

221

... More
4 x 1.5 sq. mm

40

5160

129

... More
DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

20

3120

156

... More
DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 amps switch

50

5550

111

... More
15/16 amps switch

15

2520

168

... More
3 Pin 5/6 A. socket outlet

20

2620

131

... More
6 Pin 15/16 A. socket outlet

15

3180

212

... More
DSR item No.1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.

-

-

-

... More
1 or 2 Module

2

286

143

... More
3 Module

2

324

162

... More
4 Module

3

510

170

... More
6 Module

2

390

195

... More
8 Module

3

681

227

... More
12 Module

2

584

292

... More
DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator).

-

-

-

... More
6 way (4 + 18) Double door

1

5342

5342

... More
8 way (4 + 24) Double door

1

6408

6408

... More
DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

42

11550

275

... More
Triple pole and neutral

2

2638

1319

... More
DSR item No.19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, (As per Complete Item No. 11 of the DNIT).

10

29320

2932

... More
Supply and Erection of B.L. Holder of make Anchor Panta / Havells Reo/ Gold Medal Essenza ISI marked on existing Jn. Box / Wooden block including making connection etc as required.

20

1100

55

... More
Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, (As per Complete Item No. 13 of the DNIT).

-

-

-

... More
Size 56" 1400 mm Sweep BLDC fan of Havells/ Bajaj/ Atomberg/ Crompton/ Usha/ Orient make only

5

19650

3930

... More
Supply & erection of Cabin Fan 16” sweep oscillating type complete with blades & regulator. The fan should have 2 Nos. of pull cord switches, one for oscillation and one for speed regulation. The fan should be of Havells make Swing / Crompton make WM Wind FIO (HiSpeed) / Orient make 400 mm (16") Wall-45/ Bajaj make media BW07 400 mm wall only. (As per Complete Item No. 14 of the DNIT).

2

6160

3080

... More
S/E of 1x18/20Watt. 4’ long LED box type fittings made of CRCA Sheet with tube rods to be installed on existing surface with the help of rawl plug & Screws etc. (As per Complete Item No. 15 of the DNIT)..

16

14960

935

... More
Providing and fixing MCB 4 Pole 63 AMPS, 415 volt ‘C’ curve 10 KA breaking capacity in the existing enclosure as per site requirement. The job includes making connection with suitable size with copper wire to the entire satisfaction of engineer in charge. The MCB should be L&T (Exora)/ Legrand (DX3)/ Schneider (Acti-9)/ ABB (SB200M)/ Siemens (Betagard) make only.

2

4470

2235

... More
S/I/T/C of LED Street light luminaries of Philips / Bajaj / Wipro / Keselec/ Crompton/ Surya/ Panasonic/ Keselec/ Twinkle/ LT make only. The fitting should be installed with existing GI pipe bracket on wall/ existing street light pole upto 9.5 mtr. long. (As per Complete Item No. 17 of the DNIT).

3

6225

2075

... More
Supply and Erection of Gate Light fitting with clear / frosted globe duly wired with B-22 d / E-27 lamp holder complete with LED lamp of 9 Watt. to be fixed on existing gate pillar by providing suitable arrangement. (As per Complete Item No. 18 of the DNIT).

3

4500

1500

... More
Providing and fixing following rating MCCB 4 pole 415 Volt (Thermal magnetic / microprocessor release) without MS enclosure for Over load, short circuit and inbuilt earth protection, (As per Complete Item No. 19 of the DNIT).

-

-

-

... More
125 Amp 4 Pole MCCB (Thermal Magnetic release). The MCCB should be of L&T/ Siemens/ Schneider/ Legrand/ ABB only

1

11110

11110

... More
S/E of ding dong type electronic bell including carriage, testing with suitable size of nuts / bolts and other petty material etc. as required to complete the job to the entire satisfaction of EIC. The bell should be of Cona/ Anchor/ Gold Medal/ Havells make only

2

500

250



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.