Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PROVIDING REPLACEMENT OF ALUMINIUM WIRING WITH PVC COPPER WIRING AND MODULAR ACCESSORIES IN KARUNA SADAN BUILDING AT SECTOR 11, U.T., CHANDIGARH.
PROVIDING REPLACEMENT OF ALUMINIUM WIRING WITH PVC COPPER WIRING AND MODULAR ACCESSORIES IN KARUNA SADAN BUILDING AT SECTOR 11, U.T., CHANDIGARH.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Group C

644

934

601496

... More
DSR Item No.1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
3 x 1.5 sq. mm

1545

99

152955

... More
3 x 2.5 sq. mm

500

143

71500

... More
3 x 4 sq. mm

870

215

187050

... More
DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm

1480

134

198320

... More
25 mm

2110

152

320720

... More
DSR item no. 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

55

42

2310

... More
DSR Item No.1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.

-

-

-

... More
1 or 2 Module (75mmX75mm)

40

311

12440

... More
3 Module (100mmX75mm)

20

342

6840

... More
4 Module (125mmX75mm)

26

358

9308

... More
6 Module (200mmX75mm)

30

420

12600

... More
8 Module (125mmX125mm)

35

474

16590

... More
12 Module (200mmX150mm)

28

572

16016

... More
DSR Item No.1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

104

498

51792

... More
DSR Item No.1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

146

612

89352

... More
DSR Item No.1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

194

91

17654

... More
DSR Item no. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator)

-

-

-

... More
6 way (4 + 18), Double door

13

5197

67561

... More
DSR Item no. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single pole

282

267

75294

... More
Double pole

8

686

5488

... More
Triple pole and neutral

13

1283

16679

... More
DSR ITEM No.2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

72

1222

87984

... More
DSR Item no. 2.23 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.

-

-

-

... More
For 8 way, Double door SPN MCBDB

8

869

6952

... More
DSR ITEM NO. 5.1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt )as required.

12

5610

67320

... More
DSR ITEM NO. 5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

135

53

7155

... More
DSR ITEM NO. 14.15 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.

-

-

-

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

60

259

15540

... More
DSR 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 amp. switch

644

108

69552

... More
3 pin 5/6 amp. socket outlet

85

127

10795

... More
Bell push

4

146

584

... More
Supply & erection of U PVC trunking 100mmx 50mm with cover of M.K/ Legrand/ Hansel make. The PVC Trunking should be fixed on the existing surface with the help of suitable size of steel fastners at each 1 mtr. Distance to hold the same properly. The rate include cost of material, carriage erection charges & petty material i.e. screws/ washers etc. to complete the job.

-

-

-

... More
U PVC Trunking 100mm x 50mm.

100

650

65000

... More
External angle 100mm x 50mm

10

540

5400

... More
Internal angle 100mm x 50mm

10

540

5400

... More
End Cap 100mm x 50mm.

20

125

2500

... More
Supply & erection of fan rod 3’ long

40

310

12400

... More
Supply and fixing of 12 modules (200 mm x 150 mm) G.I box suitable for accommodate the following accessories along with modular base and cover plate for modular switches in recess / surface etc as required for Computer Point with 4 Nos. 5/6 Amp. modular switch and 4 Nos. 3 pin 5/6 Amp. modular socket outlet. The job includes the cost of making interconnections with suitable copper wire, painting of box with approved paint and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site.

89

1480

131720

... More
Supply & erection of Wall/ Cabin Fan 16” sweep oscillating type complete with blades & regulator. The fan should have 2 Nos. of pull cord switches, one for oscillation and one for speed regulation. The fan should be of Havells Swing Gyro/ Orient 400mm wall 43U/PWH / Usha 400mm Mist Air DUOS/ICY/ Bajaj Esteem 400mm Wall fan make only. The cost includes the connection with adjacent light points and installed on wall with suitable size rag bolts, nuts and other material required to complete the job to the entire satisfaction of Engineer-in-Charge.

5

3020

15100

... More
Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC.

-

-

-

... More
Size 15 inches (380mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP)/ Crompton (EXHD380-6-1)/ Bajaj (Supreme Plus)/ Orient (Industrial Heavy Duty)/ Usha (Turbo HEDF900RPM) make only.

31

5230

162130

... More
S/E of 1x18/20 watt LED box type fittings made of CRCA Sheet. The fittings should be installed on existing surface. The tube rod & batten for hosing the tube rod should be of Philips/ Wipro/ Bajaj/ Havells/ Jaquar/ Surya/ Panasonic/ Crompton make only. The job includes carriage, erection, making connections testing and commissioning of the fittings as per DNIT Item no.22.

127

920

116840

... More
S/E of 1’x1’ LED fitting surface type square type with integral/ non integral driver to be installed on existing surface with the help of rawl plug & screws etc. The fitting should be Philips/ Wipro/ Bajaj/ Havells/ Crompton/ Trilux/Lighting Technologies/ Jaquar/ Panasonic/ Surya make only. The job includes the cost of testing, commissioning and making connection with 3x1.5 sq. mm copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer in Charge as per DNIT Item No.23.

44

2115

93060

... More
S/E of 2’x2’ LED fitting surface square type with integral/ non integral driver to be installed on existing surface with the help of rawl plug & screws etc. The fitting should be Philips/ Wipro/ Bajaj/ Havells/ Surya/ Jaquar/ Trilux/ LT/ Crompton/ Panasonic make only. The job includes the cost of testing, commissioning and making connection with 3x1.5 sq. mm copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer in Charge as per DNIT Item No.24.

129

2560

330240

... More
Supply and Erection of B.L Holder on the existing junction box/ wooden block including making the connection etc as required. The job includes the all labour and petty material charges required to complete the job to the entire satisfaction of E.I.C. of work. Approved makes: Anchor/ Goldmedal/ L&T/ Havells make only.

133

55

7315

... More
DSR 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Note: The MCCB should have adjustable overload and adjustable S/C protections ((Ics=100% of Icu).

-

-

-

... More
63/100 A,30KA,FPMCCB

21

8071

169491

... More
125 A,36KA,FPMCCB

3

8578

25734

... More
250 A, 36 KA FPMCCB

2

18298

36596

... More
DSR ITEM NO. 5.2.2 (CIVIL WORK) Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:

-

-

-

... More
1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) Size 1.30x0.600x0.300 = 0.234cum Total (5Nos.x0.234=1.17 cum)

1.17

10559

12355.11

... More
DSR ITEM NO. 5.9.1 (CIVIL WORK) Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete Size 1.30x0.600x2=1.56and0.30x0.600x2=0.36 sq.mtr. (1.56+0.36=1.92 sq.mtr.) = 1.92x 5Nos. = 9.60 Sq. Mtr.

9.6

381

3662.98

... More
DSR item no.13.1.1 (Civil work)

-

-

-

... More
Cement plaster (in fine sand) 1:4 (1 Cement:4 fine sand)

8

337

2701.36

... More
DSR item no.15.7.4 (Civil work)

-

-

-

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within50 meters lead as per direction f EIC.

0.84

2004

1683.84

... More
Fabrication, Supplying, Installation, Testing and Commissioning of outdoor type double door Electric Control Panel of cubical construction conforming to IEC 61439 (Part I & Part II), floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade, having suitable capacity TPN Aluminum bus bars, DMC/ SMC bus bar supports, base frame of MS channel 100mm x 50mm x 6mm size, having switchgears and accessories , internal wiring with 2.5 sq.mm PVC insulated single core cable, common copper earth bar of size 25 x 5 mm over the entire width of panel and 2 nos. earth studs, cable entry from the top & bottom, cable gland plates, numbering, labeling etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply with protection class IP 54 as required. The job includes the cost of MCCB, accessories, interconnection with solid connection, carriage and installation of cubical panel at site to the entire satisfaction of Engineer in charge. The outdoor type double door Electric Control Panel should have provision of following switchgear and accessories:- (Note:- (Note: All MCCBs shall be with ROM, Spreader terminals)

-

-

-

... More
INCOMING

-

-

-

... More
250 Amps. 36KA, four Pole, Thermal magnetic release , MCCB (Ics = Icu at 415 V) with adjustable O/L and adjustable S/C protection :- 1 No.

-

-

-

... More
BUS BAR

-

-

-

... More
TPN Aluminum bus bars (having 100% Neutral) of minimum of 300 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminum bus shall be 1 Amp/sq. mm.- 1 Set.

-

-

-

... More
OUTGOING

-

-

-

... More
63/100 Amps. 36 KA, four Pole, Thermal magnetic release , MCCB (Ics = Icu at 415 V) with adjustable O/L and adjustable S/C protection :- 6` Nos.

1.92

39100

75072

... More
Fabrication, Supplying, Installation, Testing and Commissioning of outdoor type double door Electric Control Panel of cubical construction conforming to IEC 61439 (Part I & II), floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade, having suitable capacity TPN Aluminum bus bars, DMC/ SMC bus bar supports, base frame of MS channel 100mm x 50mm x 6mm size, having switchgears and accessories , internal wiring with 2.5 sq.mm PVC insulated single core cable, common copper earth bar of size 25 x 5 mm over the entire width of panel and 2 nos. earth studs, cable entry from the top & bottom, cable gland plates, numbering, labeling etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply with protection class IP 54 as required. The job includes the cost of MCCB, accessories, interconnection with solid connection, carriage and installation of cubical panel at site to the entire satisfaction of Engineer in charge. The outdoor type double door Electric Control Panel should have provision of following switchgear and accessories:- (Note:- (Note: All MCCBs shall be with ROM, Spreader terminals)

-

-

-

... More
INCOMING

-

-

-

... More
125 Amps. 36KA, four Pole, Thermal magnetic release , MCCB (Ics = Icu at 415 V) with adjustable O/L and adjustable S/C protection :- 1 No.

-

-

-

... More
BUS BAR

-

-

-

... More
TPN Aluminum bus bars (having 100% Neutral) of minimum of 250 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminum bus shall be 1 Amp/sq. mm.- 1 Set.

-

-

-

... More
OUTGOING

-

-

-

... More
63/100 Amps. 36 KA, four Pole, Thermal magnetic release , MCCB (Ics = Icu at 415 V) with adjustable O/L and adjustable S/C protection :- 6 Nos.

6.16

39100

240856

... More
Fabrication & erection of steel shutters for electrical niches as per following specifications:

-

-

-

... More
FRAME: The shutter of suitable dimensions for electrical nitch shall be made out of 16 G.M.S. sheet. The shutter frame shall be 1-1/2”x1-1/2”x1-1/2” channel frame 4 Nos. ‘L’ type holdfasts for fixing the same on the wall. The size of the shutter frame should be suitable for 2 Nos. door angels/ single panel depending upon the size of nitches.

-

-

-

... More
DOOR PANEL: The door panel shall have support in U-Shape formation made from 16 G.M.S. sheet with 4”x3/4”M.S. channel duly spot welded to give additional strength. The door panel shall be fixed with frame with the help of concealed M.S. hinges of suitable size having good strength. The door panel shall be provided with a bolting arrangement either of Godrej type or such type so as to interlock the door panel with frame. The handle shall be of superior quality and nickel plated to facilitate its opening. The door panel must have as arrangement to provide a pad lock.

-

-

-

... More
FINISHING: The frame & the door panel should be given anti-rust, anti-grease and phosphate treatment with 3 in 1 paste and then spray painted with two coats of paint of superior quality. The shutter should be earthed properly with the existing earth with No.8SWG wire after erasing the paint from the body of the shutter. The rate includes cost of all labour and material reqd. to complete the job to the satisfaction of the Engineer-in-charge.

24

2630

63120

... More
S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA/ PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen at 100 lm/ watt (minimum) and the driver of the fitting should be workable on 140-260 Volt. The colour temperature of LED should be minimum 5000 degree Kelvin. The fitting should be of Philips/ Bajaj/ Wipro/ Havells/ Jaquar/ Crompton/ Panasonic/ Surya/ LT/ Trilux make only. The fitting should be of IP-65/66. The LED should have a life of 50000 burning Hours. The fitting should have THD15% and power factor 0.9 or above. The job includes the cost of testing, commissioning and making connection with copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer In Charge.

12

1075

12900

... More
Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 7.42, Air delivery minimum 245 CMM, 300 RPM (tolerance as per IS : 374-2019), THD less than 10%, OEM designed electronic regulator unit for speed control in various steps as per BIS (proof shall be submitted alongwith fan before installation at site) and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. The fan should be of Havells/ Atomberg/ Bajaj/ Crompton/ Usha/ Orient make only.

163

3820

622660

... More
Supply and erection of sheet metal cubical pedestal of suitable dimensions made from 50 mm X 50 mm X 6 mm thick M.S angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides and front side hinged complete with locking arrangement with 4 Nos. switchgear supporting members each of M.S. flat 50 mm X 6 mm thick of suitable length duly welded. The cubical pedestal shall have 4 Nos. legs of 50mmX50mmX6 mm each 60 cm long M.S. angle iron each long including painting, bonding to the existing earth etc. the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15cm high form ground level and 45 mm thick. The cubical pedestal shall be15 cm from the top of cement concrete platform.

-

-

-

... More
Cubical size 900 mm X 600 mm X 350 mm

1

10280

10280



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.