Chandigarh Administration Tender

View complete overview of Chandigarh Chandigarh Administration Tender

Chandigarh Administration Tender

Works
Security and Emergency Services
Eprocure
Opening Date14 Feb 2024
Closing Date26 Feb 2024
Tender Amount₹ 65,89,901 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, installation, testing & commissioning of surveillance Hard Disc Drive with the following specification:- (Please refer DNIT for complete specification of item no.4)

6

144204

24034

... More
LAYER 2, 8 PORT POE SWITCH Supply Installation testing and Commissioning of 8-port POE Layer-2 GE fixed chassis with 8 x PoE+ RJ-45 100/1000 BaseT, 2 x SFP/RJ-45 uplink ports. 1U by 1/2 rack form factor, internal AC supply (180W PoE budget or better), fan less. Order 19" rack mount kit separately. (Please refer DNIT for complete specification of item no.5)

9

306576

34064

... More
22U RACK Supply Installation Testing & Commissioning of 22U Rack for switch mounting with fan and power strip, PDU, Hardware Mounting Kit etc. as required at site to the entire satisfaction of E.I.C. Make: Netrack / Rittal / Valrack / Dlink only.

1

23920

23920

... More
6U INDOOR RACK Supply Installation testing and Commissioning of 6U indoor rack with pole mount bracket and side fan for air perforation and water proof design. Rack should be certified IP-55 as per outdoor environment. Rack should contain 3 sockets PDU. Make: Rittal / Netrack / Valrack / Dlink only.

9

47043

5227

... More
DSR Item No.1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
3 x 2.5 sq. mm

1400

205800

147

... More
DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

1800

280800

156

... More
DSR 1.53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required i)1 run of cable

1800

109800

61

... More
DSR item No.14.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
63 mm dia ( OD-63 mm & ID-51 mm nominal)

1400

371000

265

... More
OPTICAL FIBER Supply Installation testing and Commissioning of OFC Armoured outdoor SINGLE MODE 6 CORE - OS2. Should be ISO.IEC 11801 - 2nd Edition, type OS2 and ITU-T REC G 652D. Tube Identification: Single tube/Multiple tube. Fibre protection (Tube): Polybuty lene Terephthalate (PBT). Water Blocking: Thixotropic Gel (Tube) and Petroleum Jelly (Interstices). Core Wrapping: Polyethylene Terephthalate. Armouring: Corrugated Steel Tape Armour (ECCS Tape). Strength Member: Two Steel wires on periphery/Two FRP rods on periphery /Central Strength Member FRP. Sheath: UV Stabilized Polyethylene (HDPE). Maximum. Tensile Strength-Short Term: 1500N or better. Mass (Nominal) : minimum 95 kg/km, Operating Temperature range should be -40°C ±70°C Make: R&M / Siemon / Systimax / Molex / Legrand / Dlink only.

1200

98400

82

... More
Supply Installation Testing and Commissioning of SFP 1000 Base Fiber Module of Make Cisco / HPE/Juniper only.

18

328122

18229

... More
PATCH CORDS CAT 6, 1MTR: Supply Installation Testing and Commissioning of CAT6 UTP LSZH 24 AWG Patch Cord - 1 Mtr with cross separator, Manufactured from stranded wires for longer flex-life, Minimum length of 1m, and maximum length of 5m conforming to the following standards like EN 50173, ISO/IEC 60603-7 & 11801/IEC 60332-1, EN 50173-1:2011 Class E,ETL Verified AS/CA S008:2020. Make: R&M / Siemon / Systimax / Molex / Legrand / Dlink only.

42

16086

383

... More
JACK PANEL: Supply Installation testing and Commissioning of 24-port 19" 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19" 1U straight Patch Panel, 24-port,Should have integral cable management Metal shelf, Should accept Shielded as well as Unshielded jacks, Should have rear cable management shelf metallic powder coated. Make: R&M / Systimax / Seimon /Molex/Dlink only.

9

75240

8360

... More
OFC CORDS: Supply Installation testing and Commissioning of OPTICAL FIBER EQUIPMENT CORDS (MINIMUM 2 METER ) SC-LC /SC -SC. All optical fiber patch leads shall comprise of Single-mode 9/125μm fiber OS2. Jacket should be anti-rodent and outer metal spiral sheath protection, Sheath: LSZH.Make: R&M / Systimax / Seimon / Molex /Dlink only.

18

6048

336

... More
OPTICAL FIBER PIGTAILS: Supply Installation testing and Commissioning of OPTICAL FIBER PIGTAILS, 1.5 MTR SM OS2. Precision ferrule end face geometry SC Type SM. Factory polished tested and serialized. Buffer Diameter: 900um tight buffer. Minimum bend radius: install: 30 mm. Retention Strength: 100N. Cable: 900um Buffered. Sheath: LSZH.Make: R&M / Dlink/ Systimax / Seimon / Molex only.

18

6048

336

... More
Supply Installation testing and Commissioning of 24 Port Fiber LIU which have sufficient slots to accommodate 24/12 Duplex LC/SC Ports ,Should have fiber management provision inside with splice tray and other accessories, Should be rack mountable 1U, Should have Splice holder for minimum 24 Fiber cores, Should be made of Cold Rolled Steel, Material Should steel: 1.5 mm, powder-coated The enclosure/LIU should have locks to secure all the fiber terminations & must have front cable management to properly route patch cords. No of fiber ports should be upgradable up 96 ports LC/SC Style. Make: R&M / Siemon / Systimax / Molex / Dlink only.

1

11831

11831

... More
Supply Installation testing and Commissioning of 6 Port Fiber LIU which have sufficient slots to accommodate 24/12 Duplex LC/SC Ports ,Should have fiber management provision inside with splice tray and other accessories, Should be rack mountable 1U, Should have Splice holder for minimum 24 Fiber cores, Should be made of Cold Rolled Steel, Material Should steel: 1.5 mm, powder-coated The enclosure/LIU should have locks to secure all the fiber terminations & must have front cable management to properly route patch cords. Make: R&M / Siemon / Systimax / Molex / Dlink only.

9

56160

6240

... More
Supply Installation testing and Commissioning of Switch should be configured to provide Wire-Speed Non-Blocking Switching and Routing Performance at Layer 2 and basic Layer 3 on all ports. Switch has Gigabit Ethernet 1RU chassis. 22 100/1000 Base-X SFP ports, 2 SFP/RJ45 combo, 2 SFP + 1G/10G ports, one expansion slot 1558v2 support. Includes an internal AC power supply with a US power cord, manuals access card, AC backup power supply. Switch should support backup power to one non- PoE switch. RPS will be required in switch. Switch should support IPV4 and IPV6 from day one. The switch should support full Layer 2 features like STP, RSTP, MSTP/PVST,LACP/ IEEE 802.3AD, ACL, QoS and IGMPv1/v2/v3. Make: Cisco / HPE/ Juniper only.

1

252000

252000

... More
SITC of 3 KVA True Online UPS with 1 Hour backup time with battery rack (Please refer DNIT for complete specification of item no.20)

2

218800

109400

... More
Supply and erection of Steel Tabular Pole IS- 410 SP-6 swaged and welded in three steps 7.50 mtr. Long weight 93 kgs as per IS 2713 (Part I & II 1980) amended upto date with the following specifications:- (Please refer DNIT for complete specification of item no.21)

42

503160

11980

... More
Providing comprehensive AMC for 5 year (after expiry of defect liability period i.e. 1 year) for the various components as under including all part of hardware as well as software. Preventive Mtc. service of the equipment under AMC must be carried out once in fortnight. During the period of AMC service/repair calls are to be attended by the supplier within two hours from the time of such calls. (Please refer DNIT for complete specification of item no.22)

-

-

-

... More
2nd year

1

271076

271076

... More
3rd year

1

284630

284630

... More
4th year

1

298862

298862

... More
5th year

1

313805

313805



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.