Relocation Of Electrical Distribution Room
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CSIR_197517_1Bid Award Id
ViewTender No
CSIO/98/2024-25/ElectTender Authority
Central Scientific Instruments Organisation ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removal of power cable aluminium conductor up to 3.5 core 400 Sq.mm from existing cable trench by digging of ground (cable trench) up to 1 meter depth and refilling the trench and shifting of the cables as required & directed by Engineer-In-Charge.
410
-
-
Disconnection of cable end termination with compression gland upto size 3.5 core 400 Sq.mm aluminium conductor power cable as directed by Engineer-In-Charge.
54
-
-
Dismantling of metallic cable tray up to size 450mm Width from existing wall/roof and shifting the same from site to store as required & directed by Engineer-In-Charge.
80
-
-
Power Cable Supply:-
Supply of 4 core 35 sq.mm 1.1KV grade, one number XLPE insulated, aluminium conductor, armoured power cable confirming to latest IS standards.
30
-
-
Supply of LT power cable of 1.1 KV grade of size 3.5 Core 150 Sq. mm, Aluminium conductor, armoured, XLPE insulated and PVC sheathed, conforming to latest IS: 7098 Part-1 ammended up to date.
100
-
-
Supply of LT power cable of 1.1 KV grade of size 3.5 Core 185 Sq. mm, Aluminium conductor, armoured, XLPE insulated and PVC sheathed, conforming to latest IS: 7098 Part-1 ammended up to date.
50
-
-
Supply of LT power cable of 1.1 KV grade of size 3.5 Core 300 Sq. mm, Aluminium conductor, armoured, XLPE insulated and PVC sheathed, conforming to latest IS: 7098 Part-1 ammended up to date.
208
-
-
Supply of LT power cable of 1.1 KV grade of size 3.5 Core 400 Sq. mm, Aluminium conductor, armoured, XLPE insulated and PVC sheathed, conforming to latest IS: 7098 Part-1 ammended up to date.
50
-
-
SITC of Cable Tray:-
Supplying and installing of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) of size 150 mm width X 50 mm depth X 1.6 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
30
-
-
Supplying and installing of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) of size 300 mm width X 50 mm depth X 1.6 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
60
-
-
Supplying and installing of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) of size 450 mm width X 50 mm depth X 2.0 mm thickness with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
40
-
-
Cable Laying:-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size up to 35 Sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
50
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size above 95 sq. mm and upto 185 sq. mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
100
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size above 185 sq. mm and upto 400 sq. mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
85
-
-
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size upto 35 sq. mm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
50
-
-
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 35 sq. mm and upto 95 sq. mm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
45
-
-
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size above 95 sq. mm and upto 185 sq. mm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
55
-
-
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size above 185 sq. mm and upto 400 sq. mm direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
75
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size upto 35 sq. mm in the existing masonry open duct as required.
210
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size above 35 sq. mm and upto 95 sq. mm in the existing masonry open duct as required.
280
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size above 95 sq. mm and upto 185 sq. mm in the existing masonry open duct as required.
720
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size above 185 sq. mm and upto 400 sq. mm in the existing masonry open duct as required.
220
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Upto 35 sq. mm (clamped with 1mm thick saddle) on cable tray as required.
150
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) on cable tray as required.
250
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) on cable tray as required.
600
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) on cable tray as required.
180
-
-
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
20
-
-
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
20
-
-
Horizontal boring of dia. size upto 160mm and up to 1 Mtr below ground level including digging & refilling of side pits required for boring with hire & running charges of all equipment/ tool/plant & machinery/labour as required for boring etc. complete in all respect and to the entire satisfaction of EIC.
15
-
-
CABLE END TERMINATION:-
Supplying and making end termination with brass compression gland and aluminium lugs of size 4 X 35 sq. mm (32mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required:
3
-
-
Supplying and making end termination with brass compression gland and aluminium lugs of size 3½ X 70 sq. mm (38mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required:
6
-
-
Supplying and making end termination with brass compression gland and aluminium lugs of size 3½ X 95 sq. mm (45mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required:
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs of size 3½ X 120 sq. mm (45mm)of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required:
5
-
-
Supplying and making end termination with brass compression gland and aluminium lugs of size 3½ X 150 sq. mm (50mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required:
12
-
-
Supplying and making end termination with brass compression gland and aluminium lugs of size 3½ X 185 sq. mm (57mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required:
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs of size 3½ X 300 sq. mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required:
8
-
-
Supplying and making end termination with brass compression gland and aluminium lugs of size 3½ X 400 sq. mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required:
2
-
-
HDPE Pipe :- Supplying and laying of size 90 mm dia (OD-90 mm & ID-76 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
30
-
-
Supplying and laying of size120 mm dia (OD-120 mm & ID-103 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
20
-
-
LT Cable Joint:-
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for size 4 X 35 sq. mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
1
-
-
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for size 3½ X 150 sq. mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2
-
-
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for size 3½ X 300 sq. mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
1
-
-
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for size 3½ X 400 sq. mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
1
-
-
Rubber Mat:-
Providing of rubber mat 1 metre wide and 6mm thick to withstand 3.3KV dielectric strength as per IS 5424-1969
15
-
-
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
4
-
-
S/F of MCCB:-
Providing and fixing 250 A, 35 KA,TP MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
2
-
-
Earthing:-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
8
-
-
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
60
-
-
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
80
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
20
-
-
WIRING-
Dismantling of the following material safely and shifting from site to store as per requirement as directed by the Engineer-In-Charge:-
a) Ceiling Fans - 02 Nos. b) Smoke Detector - 5 Nos. c) Fire survival Cable - 110 Metre
d) Tube Light Fittings - 5 Nos.
e) Hooter - 02 Nos.
f) MCP- 01 No.
g) Responce Indicator-01 No.
h) Exhaust Fan = 01 No. i) IP Box = 04 Nos.
1
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel/ PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (i) Group-C
12
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the 2X2.5 sq mm + 1X2.5 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
40
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the 2X4 sq mm + 1X4 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Note:- this item includes PVC conduite pipe + PVC wire)
30
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the 2X6 sq mm + 1X6 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Note:- this item includes PVC conduite pipe + PVC wire)
20
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
2
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
2
-
-
Supply of LED Batten of rating 20W, minimum lengh 1100mm, lumens effieciency not less than 100lm/watt, suitable for 230V, 50 Hz, single phase AC Supply, complete as required. Make Havells/CG/Wipro.
6
-
-
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
6
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
2
-
-
Supply of Metallic Body Exhaust Fan of size 300 mm sweep, with G.I. sheet louver shutter, Grey in color, RPM: 900-950, four number blades, Air delivery (minimum) 1145 m3/h, low noise level, suitable for 230V, 50 Hz, single phase AC Supply, complete as required. Make: Havells/USHA/CG.
2
-
-
Installation of exhaust fan of size upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
2
-
-
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
2
-
-
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. As required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) required.
10
-
-
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
2
-
-
Supplying and fixing 8 way double door, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
1
-
-
Supplying and fixing 25 A, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6
-
-
Supplying and fixing of 25mm size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20
-
-
Supply and fixing 20mm to 25mm PVC flexible pipe alongwith accessories on surface as required.
8.8
-
-
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
10
-
-
FIRE ALARM SYSTEM:-
Supplying & fixing of powder type fire extinguisher (stored pressur type conforming to IS:15683:2006) 6 Kg. capacity with initial refill of ISI marked ABC power completed with squeeze grip, release valve, discharge pipe, pressure gauge, locking safety clip, mounting bracket etc. including fixing on wall as required.
2
-
-
Supplying, installation, testing and commissioning of Carbon Dioxide (CO2) gas type fire extinguisher of 4.5 Kg. capacity with initial charge i/c discharge hose and horn, squeeze grip release valve, locking arrangement, bracket with two screw and sleeve i/c fixing on wall as required. (Fire extinguisher shall be ISI marked conforming to IS: 15683)
2
-
-
S/E of sand buckets of 8 Itr. Capacity each made out of 24 Gauge G.I sheet. The buckets with sand shall be hanged on Suitable size of angle iron stand fabricated out of 1¼" x 1¼" x 1/8" made angle iron having hooks for hanging the buckets in two rows. The job includes the cost of painting with two coats of red paint of superior quality after one coat of primer on buckets and stands to complete the job up to the entire satisfaction of the Engineer-In-charge.
2
-
-
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
60
-
-
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
1
-
-
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
6
-
-
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc. as required.
1
-
-
Supplying and fixing round/square PVC Junction Box of size 100mm (approx.) as required and approved by the Engineer-In-Charge.
4
-
-
Supplying and making end termination with brass compression gland of size 12mm for 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor.
14
-
-
Programming of following Fire Alarm Components with FAS repeater panel and testing etc. complete as required to update the FAS of Detnov make:-
i) Addressable manual call point - 1 No.
ii)intelligent addressable smoke / thermal detector - 5 Nos.
iii) RI-01 No.
1
-
-
Dielectric/Insulating rubber shoes/Boot 20KV, of size 7-10 IND/UK. Make: Honeywell/Resprix/Harvik.
4
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand andmanufacture.
110
-
-
Civil Work Items:-
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within CSIO. All kinds of soil.
90.9
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, with in CSIO and for all lift.
60
-
-
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
10.35
-
-
Surface dressing of the ground including removing vegetation and in- equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
150
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources)
21.48
-
-
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-Ill) derived from natural sources: 4 graded stone aggregate 12.5 mm nominal size derived from natural sources)
9.2
-
-
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
38
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
14.67
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
14.36
-
-
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete.
67.23
-
-
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
84
-
-
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
4.32
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
1723.2
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
5.64
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement: 6 coarse sand)
29.72
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
84
-
-
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. Grace/Dorset/Sandhu or equivalent make.
2
-
-
Providing and fixing Powder coated aluminium (minimum
thickness of powder coating 50 micron) ISI sliding door bolts, transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm
2
-
-
Providing and fixing Powder coated aluminium (minimum
thickness of powder coating 50 micron) tower bolts, ISI marked, anodised transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm
6
-
-
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron)tower bolts, to required colour or shade, with necessary screws etc. complete : 150x10 mm
6
-
-
Providing and fixing aluminium handles, ISi marked, Powder coated aluminium (minimum thickness of powder coating 50 micron)
to required colour or shade, with necessary screws etc. complete : 125 mm
6
-
-
Providing and fixing aluminium hanging floor door stopper, ISi marked, Powder coated aluminium (minimum thickness of powder coating 50 micron) to required colour and shade, with necessary screws etc. complete. Twin rubber stopper.
2
-
-
Providing and fixing aluminium casement stays, ISi marked, Powder coated aluminium (minimum thickness of powder coating 50 micron) to required colour and shade, with necessary screws etc. complete.
4
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer all complete.
3663.91
-
-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate.
48
-
-
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use
cm 3.70 of chequered plate wherever required, all complete
421.23
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. JSW/Tata.
170
-
-
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
196
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
160
-
-
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer Asian/Nerolac/Dulex or equailant make and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
160
-
-
Factory made 50mmx47 mm with a wall thickness of 5 mm door frame PVC extruded sheet including carriage. Two or more coats on new work
405
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
200
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.J.K/Birla/Asian or equivalent make.
320
-
-
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within CSIO as per direction of Engineer-in-charge.In cement mortar
12.88
-
-
Removing mortar from bricks and cleaning bricks including stacking within (stacks of cleaned bricks shall be measured):From brick work in cement mortar
4000
-
-
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within CSIO of area 3 sq. metres and below
4
-
-
Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking with in CSIO lead as per direction of Engineer-in-charge.
2000
-
-
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond CSIO for all leads including all lifts involved.
25
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 100 mm nominal dia Pipes. Prince/ Finolex/Astral or equivalent make.
10
-
-
Supplying and fixing with welding or nut bolt Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & Painting to be paid for separately).
400
-
-
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.NTC or equivalent make.
30
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
216.64
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
72
-
-
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides
4.2
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) Modiguard/ Saint gobain or equivalant make.
9.6
-
-
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5 mm depth and 5 mm width
20
-
-
Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. Godrej/ Harison or Equivalent make.
1
-
-
Providing and fixing aluminium powder coated round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge. Powder coated minimum thickness 50 micron aluminium
4
-
-
Carrying out petty job of welding works with necessary tools welding set & rods etc for petty works at different location which can not be measured as per direction of engineer -in-charge . For shifting old truss.
12
-
-
Carrying out petty jobs of misc.petty works with all necessary tools ,rehri,kassi etc at different location which can not be measured as directed by engineer -in-charge. For shifting old truss.