Tata Memorial Centre Tender
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.
Tata Memorial Centre Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date9 Aug 2024
Closing Date19 Sep 2024
Tender AmountRefer Documents
Costs
EMD
₹ 3,12,420Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_TMC_820762_1Bid Award Id
ViewTender No
HBCHRC/ENGG/MEC/MGPS/24/NIT/04Tender Authority
Tata Memorial Centre ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Emergency Oxygen Supply System :Supply, Installation, Testing and Commissioning of Emergency Cylinder Manifold: Size 4+4 class D cylinder Oxygen Supply System. It should be as per tender technical specifications and approved makes.
1
-
-
Nitrous Oxide (N2O) System
-
-
-
Fully Automatic Manifold Control Panel for Nitrous Oxide: Supply, Installation, Testing and Commissioning of Fully Automatic Digital Control panel for Nitrous Oxide Manifold of 1000 LPM capacity. It should be as per tender technical specifications and approved makes.
-
-
-
Nitrous Oxide Manifold System, (4+4 size):Supply, Installation, Testing and Commissioning of Two Sided Cylinder Manifold bank: Size 4+4 Nitrous Oxide supply system . It should be as per tender technical specifications and approved makes.
1
-
-
Emergency Nitrous Oxide Manifold System, ( 2+2 size):Supply, Installation, Testing and Commissioning of Emergency Cylinder Manifold: Size 2+2 Nitrous Oxide supply system. It should be as per tender technical specifications and approved makes.
1
-
-
Medical Air Plant
-
-
-
Medical Air Plant unit (Oil Free Reciprocating Compressor) including electrical control panel: Design, Supply, Installation, testing and commissioning of Oil Free Air cooled Reciprocating Compressor Medical Compressed Air System having a minimum compressor capacity of 1200 LPM with maximum working pressure of 8bar as per tender technical specifications including accessories Motor:- 15Hp(Suggested) or as per actual selection,3Ph,415V with Starter control panel having suitable MCCB/MCB, Contactor, Relay, Timer, PSR, Phase reversal relay, single phase preventer, PLC with auto/Manual switch, Safety mechanism & digital display of all parameters etc, RPM-2900. Suitable new PCC/RCC foundation with plaster, Anti vibration arrangement of cushy foot mountings , lifting, shifting, loading, unloading, Lateral shifting and moving the Medical Air Plant locating the same on foundation. Houskeeping and Disposing all type of generated debris and scrap out of HBCHRC is deemed to be included in this item cost. Contractor to submit proposed Oil Free Air cooled Reciprocating Compressor Medical Compressed Air System model with duty curve. The entire work shall be complete as per specifications & as per directions of Engineer-in-charge.
3
-
-
Air Drier Package: Medical Air Drier duel desiccant Air Drier Package (Heatless) including pre-filter, after filters, pressure gauge, Dew Point Monitors 40CFM
3
-
-
Medical Vacuum Plant including electrical control panel: Design, Supply, Installation, testing and commissioning of Medical Vacuum Pump System of Minimum Piston Displacement(PD)-149.6CFM Vacuum in HG:-29.2Inch,Motor:- 10HP(Suggested) or as per actual selection,3Ph,415V with Starter control panel having suitable MCCB/MCB, Contactor, Relay, Timer, PSR, Phase reversal relay, single phase preventer, PLC with auto/Manual switch ,Safety mechanism & digital display of all parameters etc ,RPM-900 or as per actual selection, The quoted price shall include cost of Standard vacuum pump with V sheave, Base plate, Motor pulley, Slide rails, V- belts, Belt guard, Silencer, Pressure switch Suitable new PCC/RCC foundation with plaster, Anti vibration arrangement of cushy foot mountings , lifting, shifting, loading, unloading, Lateral shifting and moving the Medical Vacuum Plant locating the same on foundation. Houskeeping and Disposing all type of generated debris and scrap out of HBCHRC is deemed to be included in this item cost.. Contractor to submit proposed Vacuum pump model with duty curve. The entire work shall be complete as per specifications & as per directions of Engineer-in-charge
3
-
-
Desiccant Air Dryer: Design, Supply, installation, Testing & Commissioning of Double stage, Dual Tower, Desiccant Air Dryer,50 Cfm working and 50 Cfm standby or as per actual selection with Pre filter & 3 Stage Filter and making necessary Copper pipeline connection ,Valve etc in all respect The quoted price shall include new PCC/RCC foundation with plaster, Anti vibration arrangement of cushy foot mountings, lifting, shifting, loading, unloading, Lateral shifting and moving the Air Dryer locating the same on foundation., Housekeeping and Disposing all type of generated debris and scrap out of HBCHRC is deemed to be included in this item cost. ( 1 set= 1 No 50 CFM working + 1 No 50 CFM standby)
1
-
-
Air Receiver :
-
-
-
Design, Supply, installation, Testing & Commissioning of The Receivers Tank should be suitably designed with capacity of minimum 1500 litres at an operating pressure of 16 bar. to handle the designed load requirement. and making necessary Copper pipeline connection ,Safety Valve, guage, Auto Drain Valve etc in all respect The quoted price shall include cost of Suitable new PCC/RCC foundation with plaster, Anti vibration arrangement of cushy foot mountings ,lifting, shifting, loading, unloading, Lateral shifting and moving the Receivers Tank locating the same on foundation, Housekeeping and Disposing all type of generated debris and scrap out of HBCH & RC, Muzaffarpur is deemed to be included in this item cost.
1
-
-
Air filter for Compressor suitable for Indian Compressors
2
-
-
4 Bar pressure reducing system
2
-
-
7 Bar pressure reducing system
2
-
-
Auto Drain Valve
1
-
-
4" dia. Dial Pressure Gauge for Air
2
-
-
Vacuum Receivers
-
-
-
Design, Supply, installation, Testing & Commissioning of The Receivers Tank should be suitably designed with capacity of minimum 2000 litres at an operating pressure of 16 bar. to handle the designed load requirement. and making necessary Copper pipeline connection, Safety Valve, gauge, Auto Drain Valve etc in all respect The quoted price shall include cost of Suitable new PCC/RCC foundation with plaster, Anti vibration arrangement of cushy foot mountings, lifting, shifting, loading, unloading, Lateral shifting and moving the Receivers Tank locating the same on foundation, Housekeeping and Disposing all type of generated debris and scrap out of HBCHRC is deemed to be included in this item cost.
1
-
-
Bacterial Vacuum filter
1
-
-
4" dia. Dial Pressure Gauge for vacuum
2
-
-
Pressure Switch for vacuum system
2
-
-
Supply, Installation, Testing and Commissioning of Medical Grade Copper pipes : Solid drawn, seamless, deoxidized, non- arsenical, half hard, tempered and degreased copper pipes including Copper Fittings(as per site requirements), Pipeline Supports & installations. It should be as per tender technical specifications and approved makes.
-
-
-
76 mm OD x 1.5 mm thick
300
-
-
54 mm OD x 1.2 mm thick
350
-
-
42mm OD X 1.2mm thick
450
-
-
28mm OD X 1.0 mm thick
250
-
-
22mm OD X 1.0 mm thick
180
-
-
15mm OD X 1.0 mm thick
200
-
-
12mm OD X 1.0 mm thick
100
-
-
Supply, Installation, Testing and Commissioning of Imported Lockable line Valves or Isolation valves. It should be as per tender technical specifications and approved makes.
-
-
-
12 mm ball valve
15
-
-
15 mm ball valve
15
-
-
22 mm ball valve
15
-
-
28 mm ball valve
14
-
-
42 mm ball valve
6
-
-
54 mm ball valve
8
-
-
76 mm ball valve
8
-
-
Supply, Installation, Testing and Commissioning (SITC) of Imported Area Digital Alarm Panel for 5 gas services (Oxygen, N2O, MA-4 bar, Air-7 bar & Vacuum). It should be as per tender technical specifications and approved makes. Medical Gas Area Alarm for 5 services
3
-
-
SITC of Zonal VALVE BOX (with gauge and other accessories): Supply, Installation, testing and commissioning of Area Valve Boxes. as per specification Valve Box - 5 Gas Service (Oxygen, N2O, MA-4 bar, Air-7 bar & Vacuum).
3
-
-
Electrical Control Panel: Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of MCC panel cubicle type with suitable Aluminium bus bar with suitable Incomer MCCB having outgoing 3Nos MCCB for 15HP Medical Air Plant or as per actual selection , 3Nos MCCB for 100HP Medical Vacuum Plant or as per actual selection with spare feeder for 1 no 15HP or as per actual selection & 1 No 10HP or as per actual selection . Control panel shall be made of CRCA 14 SWG sheets. Control panel shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer with RAL 7032 or 7035. Panels shall be independent, floor mount type with IP 65 protection. Cable entry required from top/ bottom through gland plates.2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Quoted rates shall inclusive of cables, cable trays earthing (in accordance to specification) from panel to each motor / equipment. Panel shall have suitable MCB/MCCB, power contactor, overload relay, timer, motor protection device and CT's. Starters shall provide motor protection from Single phasing, reverse phasing, overload, Low Voltage. Ammeter and voltmeter, on, off & trip Lamps, RYB indicators, energy consumption meter, frequency meter shall be provided on panel. Note: The control shall be for 3 Nos Air compressors and 3 Nos Vacuum pumps with duplexing and cascading.
1
-
-
Electrical Wiring inside Gas Plant Room including supplying and fixing necessary wires, cables, clamps, glands, terminals, nuts, bolts, screws, rawl plugs etc including all labour & tools in cable trays/ trenches in workman like manner as directed by the Engineer in charge.
1
-
-
Civil Works
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge.
-
-
-
All kinds of soil
100
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
40
-
-
PCC WORKS
-
-
-
1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
8
-
-
RCC WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
-
-
-
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
25
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
-
-
-
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
15
-
-
Centering and shuttering including strutting, propping etc. and removal of form for :
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete
30
-
-
Centering and shuttering including strutting, propping etc. and removal of form for :
-
-
-
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
200
-
-
Centering and shuttering including strutting, propping etc. and removal of form for :
-
-
-
Suspended floors, roofs, landings, balconies and access platform
50
-
-
STEEL WORKS
-
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
600
-
-
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete
-
-
-
Fastener with threaded dia 12 mm
100
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
-
-
-
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
26
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level
-
-
-
Thermo-Mechanically Treated bars of grade Fe-500D or more.
2500
-
-
MASONARY WORKS
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
-
-
-
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
6
-
-
Extra for depth for manholes Size 90x80 cm
-
-
-
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
4
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
-
-
-
Cement mortar 1:6 (1 cement : 6 coarse sand)
7
-
-
12 mm cement plaster of mix
-
-
-
1:6(1 cement: 6 fine sand)
35
-
-