South East Central Railway Tender

... More
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

South East Central Railway - SECR Tender

Works
Electronics Equipment
Telecommunication Services
Security and Emergency Services
Electrical and Electronics
Ireps
Opening Date20 May 2025
Closing Date12 Jun 2025
Tender Amount₹ 5,16,86,728 
Notes
Download

AI Insights

Technical Capacity
... View More
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during the last 07 years: 1. Three similar works each costing not less than 30% of the advertised value of the tender, 2. Two similar works each costing not less than 40% of the advertised value of the tender, 3. One similar work costing not less than 60% of the advertised value of the tender. Similar work includes installation or modification of PI/RRI/EI/IBS/ABS/LC gate interlocking or MACLS outdoor signaling works, as well as works like excavation of trench, laying of cables, installation of earth pits, supply of furniture, etc. The amounts for various items are: - excavation of trench (Rs. 97.00 to Rs. 750.00 per meter), - laying of cables (Rs. 254.00 per meter), - installation of earth pits (Rs. 1004.00 per job), - supply of furniture (Rs. 24870.00 to Rs. 98850.00 per number). The bidder should have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of Earth Enhancement Material (Each Bag consisting of 11.5 Kg) for Earthing and bonding system. Inspection by Rites. Here job unit stands for Bags.

550

1200

660000

... More
Supply of Linear Heat Sensing Interface module with EOL with with zone module (As per RDSO specification no. RDSO/SPN/217/2021 ver 3.0 or latest amendment). Inspection by Rep. of CSTE/CON/BSP.

18

100557

1810026

... More
Supply of clip on meter AC/DC with carrying case make Fluke or similar with standard accessories along with engineering and operating manual. Inspection by Rep. of Railway Engineer.

2

14713

29426

... More
Design & Preparation of Circuits and drawings:- Design, Preparation & checking of documents and Circuit diagram and drawings :- f) Other Signalling Drawing in size U(A3) as per SEM sheet (wiring in location box) Here job unit stands for Number of Sheet.

50

1004

50200

... More
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. (i) all soils including soft rocky area. (b) Depth 1.0 Mtr. & width 0.3 Mtr.

6

76590

459540

... More
Supply of maintenance console (PC & printer) with one set of table and chair for datalogger/RTU for online tracking and monitoring of station position as per "annexure B " enclosed. Inspection by Rep. of Railway Engineer

2

98850

197700

... More
Relay Rack for 'Q' Series Relay as per Drg. No: SK/DRG/OL/SER/192 SH 2/2. The relay racks must be powder coated of stone grey colour. Inspection by Rep. of Railway Engineer.

6

9386

56316

... More
Steel Apparatus Case(Large) as per Drg.No.Con/SK/1/1/86 , with E type lock on both side having ward No.32. Inspection by RITES.

35

15782

552370

... More
Fixing of concrete cable route marker at 30-40 meter and at diversion point including supply & transportation of cable route marker at site. Detail size & fixing of cable route marker should be followed as per drawing no. SDO/Cable laying/020.

150

415

62250

... More
Supply of the following furnitures for SM / relay room. Inspection by Rep. of Railway Engineer. (d) 2 drawer filling cabinet STVFXDM 2086 or latest. Make: Godrej .

4

19770

79080

... More
Cable PVC insulated single core unsheathed with plain annealed copper conductor as per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by RDSO. (c) 16/0.2 mm dia. (80% grey & 20% yellow)

10

10784

107840

... More
Laying of second class bricks including supply of required quantity at site on 10 single/multiple cable laid in the trench (Approx 9 bricks per mtr).NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no. 1 to 2 as mentioned above till commissioned.

6

32603

195618

... More
Alteration of existing Q-series/Composite Relay Racks and cable termination racks. 2 NOTE: Payment can be released in a part for the above said work after completion of- (i) Errection- 15%, (ii) Wiring, testing, painting,earthing & writings etc - 75% , (iii)Commissioning of Relay rack/Composite rack/CTR- 10% of Schedule rate.

6

19785

118710

... More
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning 2 etc., including bailing out water and disposal of extra soil. (ii) Hard rocky area including concreting. (b)Chiseling up to a depth of 0.4 m to 0.5 m and width 0.3 m at the bottom as instructed by site engineer.(for single cable) with hydraulic breaker to break concrete structure/rock

100

97

9700

... More
Relay, AC Immune, plug-in type, Style "QNAI'', Neutral line, 24V DC 8F.8B contacts, 3 front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23.The interlocking code for this unit shall be ABDGH. Inspection by RDSO.

40

4032

161280

... More
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning 1 etc., including bailing out water and disposal of extra soil. (ii) Hard rocky area including concreting.(a) Chiseling up to a depth of 0.7 M and width 0.3 M at the bottom (for multiple cable) with JCB/mechnical means for soft rocky area/ murum/concrete structure etc.

100

152

15200

... More
Supply of TDR Based Cable fault locator for Metallic cables viz LV Power Cable/Control Cables/ Signalling Cables fault location Accepted/ Offered Make/Model : Tempo Communication / Special Cablescout CS90 stanlay ) or similar of make greenlee/megger. IR Kit as per attached annexure 1. Inspection by RITES. Annexure 1:- TECHNICAL SPECIFICATION FOR "TELECOM TDR CABLE FAULT LOCATOR SET The TDR fault locator must be suitable for use by a wide range of operation of all levels of technical knowledge. It must be capable of measuring distance to fault in telecom and signalling cables: Open, short, load coils, bridge taps/laterals, cross, splice/joint faults in copper / metallic cables.•The instrument should be able to locate the following faults: The instrument should have following features: - Should have zoom function - Should measure distance to fault in meters, feet or time - Should have menu push buttons to navigate through the cable length - Facility to select cable type from built in menu or create custom cable types, with present parameters including Vop. 11 Pulse width, VP, gain, and vertical position are automatically selected - Cloning feature : Cable Tables/Settings should be possible to be 'cloned' via SD/USB Card from one TDR unit to another - Instrument should contain help button for guiding the operator on control and displayed values. Physical Specification: Size: >= 255 mm x 155mm x 50 mm Weight: 0.95 kg Power Supply: : Rechargeable Lithium ion battery pack Specifications: Test Signal Output 1/2 Sine Pulse Widths for precision TDR measurement 1 ns Additional pulse widths required 5ns, 25 ns Dead zone 0m Resolution 0.075m Filtering 1, 2 , 4 , 8, 16, 32 Automatic far end detection feature Should be provided Input Protection ±400 V, DC Display Type Should be "Full Color" LCD display , backlit with display resolution 800 x400 or higher Display size >= 6.8 inch Operating temperature 0 to 50 deg C Communication interface USB Data Storage >= 8GB SD card should be built in to store traces Certification Instrument should be CE Certified Standard accessories: The equipment should be provided with Test Leads, Soft carrying case with shoulder strap.

2

269984

539968

... More
Cement Concrete of proportion 1:3:6 with graded aggregate of size 25mm. and below.

-

-

16

... More
Electric Point Machine-IRS type 220mm Throw(CG make), High thrust(AC immunity 160 V AC), non-trailable to operate on 110 V DC complete with Lock & Detector slides, cable terminal box 5 and Clamp lock & Ground connections for 60 Kg. Rail confirming to IRS: S 24 /2002 & Assy. Drg. no.- RDSO/S/11000 & for Motor IRS : S 37/82. Details of Ground connection : Ground connection clamp type for 60 Kg rail 220 mm throw as per Crompton Greaves drawing (i) Lock Rod Drg. CSQ- 3456-57-58-59, (ii) Detector Rod Drg. No. CSQ 34 36 37 , (iii) Drive Rod Drg. no. CSQ-3460. This also includes supply of insulating materials as required for each set. Inspection by RDSO.

20

200459

4009180

... More
Supply, installation testing commisssioing of 2X1.5 sqmm Fire survival flexible/Un- 18 armoured cable. Un-armoured cables should meet fire performance test under simultaneous action of Flame, water stress and impacts on single sample at 950°C for minimum 2 hours, certified by UL or FM or Vds or LPCB or BRE Global or any recognized lab by Government of India and shall comply to RDSO/SPN/217/2021 Ver 3.0 or latest.Inspection by RDSO.

2500

160

400000

... More
Laying of Signalling Cable/Power/Quad cable / PIJF cable in the excavated trench to Drg.No:CON/SK/T/5.Transportation, supply of 'U' clamps and anchoring of cable at every 10 Mtrs with 6 'U' clamp to Drg.No:CSTE/C/Cable/81 including back filling with excavated earth and ramming of trenches after cable laying.NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no. 1 to 12 as mentioned above till commissioned.

25

16740

418500

... More
Cable PVC insulated single core unsheathed with plain annealed copper conductor as 4 per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by Rep. of Railway Engineer. (e) Multi strand ISI copper cable (16 Sq.mm ) (Red-50%, Black-50% & Green-0%).

1

122245

122245

... More
Design & Preparation of Circuits and drawings:- Design, Preparation & checking of documents and Circuit diagram and drawings :- g) Maintenance Register as per Requirement

10

125

1250

... More
Alteration Modification, cable termination, wiring, testing & commissioning o f existing 6 Integrated power supply panel a s per approved power supply diagram a n d specification. T h e contactor h a s t o supply arrangements a t central relay room, goomties on original tracing paper of size 60cm.x42cm. with 8 computer prints in the format supplied by railways.

6

7227

43362

... More
Transportation, installation and commissioning of Linear Heat Sensing system.

-

-

14

... More
Supply of Output Module which will provide potential free (NO/NC) contact to existing 12 Data Logger. Complying to the RDSO/SPN/217/2016 Ver 3 or latest. Note:- The contractor will provide potential free contact for goomty and Relay Room only. The connectivity with existing data logger will be done by Railway. Inspection by Rep. of Railway Engineer.

9

8949

80541

... More
Relay AC immune Plug in type Style 'QNNA1, twin neutral line, 24VDC 6F/2B contacts 4 each for LH and RH, front and back contact metal to carbon , complete with plug board, retaining clips and connectors conforming to BRS:960,IRS:S 60, IRS:S 34 & IRS:S 23. Interlocking code of this unit shall be CDEHX. Inspection by RDSO.

50

5085

254250

... More
Laying and Fixing of galvanised iron pipe (GI Pipe) with threaded collars (for jointing pipe) of 80 mm nominal dia Spec.No.IS-1239 medium grade, on bridges, culverts, drains including supply and transportation of GI pipes and all other materials required for fixing the pipe to 7 Drg.No.Con/SK/T/2 and drawing of Signal/Power/Quad cables inside the pipe with masonary works over the entire length of the bridge and at entry and exit of the culvert and curing for 72 hrs, drilling of holes on the pipe at 10 cm apart to be clamped 2 Mtrs apart on culvert, for the Signalling, quad, power cable.NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no. 1 to 12 as mentioned above till commissioned.

50

761

38050

... More
Design & Preparation of Circuits and drawings:- Design, Preparation & checking of documents and Circuit diagram and drawings :- d) (i) Design & development of cable corage plan in size U(A3) as per SEM.Here job unit stands for Number of station.

2

2511

5022

... More
Supply of Single Channel Laser or High power LED Based Aspiration Detection Unit with programmable 4 stage alarm generation & with 4 addressable modules. It should have Auto cleaning 16 facility in optical chamber, electronic discrimination of particle size, ultrasonic airflow sensing Auto learn feature with TCP/IP network Capability. The aspiration system shall also include external power supply unit with battery backup. Approval-UL/CE/LPCB/VDS Listed and shall comply to RDSO/SPN/217/2021 Ver 3.0 or latest. (Materials will be inspected by RDSO)

30

359288

10778640

... More
Design & Preparation of Circuits and drawings:- Design, Preparation & checking of documents and Circuit diagram and drawings :-e) Design and development of Circuit Diagram/Logic in size B(A3) as per SEM sheet including contact analysis. Here job unit stands for Number of Sheet.

100

1004

100400

... More
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning 2 etc., including bailing out water and disposal of extra soil. (ii) Hard rocky area including concreting.(a) Chase cutting and smoothening of inside surface of sizes 0.08 m deep and 0.17 m width at platform and cemented floor area.

50

115

5750

... More
Wago / phoneix terminal blocks (Part no.280-874). 4 conductor disconnect terminal block. Inspection by Rep. of CSTE/CON/BSP. It includes:-(i) 4 conductor disconnect terminal block for test and measurement; 0.08 mm.sq.- 2.5mm.sq., Center marking with slot test for test plug dia 2mm/0.079 In and dia 2.3mm/0.091 in; Carrier rail din 35: front-entry; with knife disconnect large 9 cage clamp connection, grey.(ii) End and intermediate plate, 2.5 Mm/0.394 in wide carrier rail din 35, grey (Wago part no. 249-117)(60 nos)(iii) Screw end stop for carrier rail (10 nos)(iv) steel carrier rail;35 X 7.5 mm, 1 mm /0.039 in thick; unslotted (Part no. 210-229/PW11-0000).(60 nos)(v) WSB quick marking system; horizontal; 1 ... 10 (10x); for width 5-17.5 Mm; 10 strips of 10 marker per strip (200) per card; consecutive numbers white (Part no. 209 - 502S).(60 nos)& (vi) Adjacent jumper nominal current 24A; Insulated Grey.(60 nos)

1000

76

76000

... More
Excavation o f earth pit, transportation, placing and fixing of earth electrode with 17 construction of cement encloser to Drg.No.CON/SK/T/9 and CON/SK/T/9A and drawal of GI wire wrapped on MS strip (35 x 6 mm) from earth electrode to all signalling equipments, including fixing and soldering of lugs at both end of the wire.

20

1941

38820

... More
Supply of Manual call points, Push type & resettable with key, with In-built isolator. Shall be VdS/UL/FM/EN/LPCB compliant and shall comply to the RDSO/SPN/217/2016 Ver 3 or latest. Inspection by Rep. of Railway Engineer.

12

5712

68544

... More
Supply of Hooter cum Strobe complying to the RDSO/SPN/217/2016 Ver 3 or latest. Inspection by Rep. of Railway Engineer.

12

7806

93672

... More
Supply of ferrules of different colour, printing termination details / Functions in 20 different colours as per Railway specification and installation in Relay room, Location Box and Power board etc, at various stations and LC gates as per instruction of Engg. in charge. All materials required for the work shall be supplied by the contractor. Inspection by Rep. of CSTE/CON/BSP.

100000

11

1100000

... More
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. (iii) Preparation of Cable duct upto depth 3 0.7 mtr & width 0.3 mtr in hard rocky area with the help of hydrolic breaker and supply and placing of half round hume pipe and concreting upto 100 mm(proportion 1:3:6) using concrete mixture after laying of cables. It includes all materials required at site for concreting including cement and curing upto 72 hrs and then back filling.

100

750

75000

... More
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning 4 etc., including bailing out water and disposal of extra soil. (iii) Track crossing, Road Crossing by pushing method (HDD method) at culverts/ track / pucca road crossing at a depth not less than 1 meter with reference to bottom of rail/road surface including supply of (a) HDPE pipe/DWC pipe(4 inch dia)

600

1080

648000

... More
Supply of the following furnitures for S M / relay room. Inspection by Rep. of Railway Engineer (a)Plain Storage Almirah, Model no.-STSTW000 (Large) or latest. Make: Godrej

2

24870

49740

... More
Maintenance of the installation under competent supervisor of contractor.

-

-

3

... More
Supply of the following furnitures for SM / relay room. Inspection by Rep. of Railway Engineer (b) Drawer filling cabinet STVFXDM 4086 or latest. Make: Godrej .

2

25356

50712

... More
Supply Fire Alarm System of Microprocessor based intelligent, addressable, modular, 1 loop (minimum 125 detector/devices per loop- expandable to 2 loops) Fire Alarm Control Panel with LCD display with 320 Character with soft keys for displaying alarm, events and operating functions, Day/ Night operation function, Remote maintenance service feature etc. The panel should be multi- protocol ie able to support at least 2 additional different makes of addressable detectors. The panel 9 should have minimum two relay outputs & 1 Monitored Sounder Output. It should have provision to be connected to repeater panels in future. The panel shall capable to operate on 240 volts AC power supply, automatic battery charger, 2 4 volts, sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condition as per detailed specifications complete as required. Panel Should Be VdS/UL/FM/EN/LPCB Certified as per RDSO Specification No. RDSO/SPN/217/2016 Ver 3 or latest. Inspection by Rep. of Railway Engineer. Annexure: E

9

83776

753984

... More
Transportation, installation, testing & commissioning of fuse indication cum monitoring and automatic changeover system as mentioned above.

6

9469

56814

... More
Supply of 3 source Auto changeover panel of capacity 63Amps as per RDSO's specification No. TI/SPC/PSI/-CLS/0020 (with A&C slip No1 to 4) or latest. Inspection by Representative of RITES. Here per unit denotes numbers

30

35700

1071000

... More
Installation, Testing and commissioning of all above items as per requirement at site. The work will execute as per instruction of representative of Railway Engineer.

3

17553

52659

... More
Design & Preparation of Circuits and drawings:- Design, Preparation & checking of documents and Circuit diagram and drawings :- (ii) Design & development of cable route plan in size U(A3) as per SEM. Here job unit stands for Number of station.

2

1256

2512

... More
Laying of RCC pipe including supply of required quantity at site with collars (for jointing pipe) 150 mm nominal dia to Spec.No:IS-458 in excavated trench and laying of Signalling/ Power 8 cable/PIJF cable/ Quad cables/HDPE pipe through RCC pipe. Power cable shall be laid in the same trench alongwith signalling/Quad cables but in a separate pipe RCC pipe at track/pucca road/ Platform crossing/ level crossing gate etc.NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no. 1 to 12 as mentioned above till commissioned.

50

775

38750

... More
The excavation of pit, casting of concrete foundation including surrounding earthwork along the foundation, erection, installation and wiring of steel appartus ca se , fixing o f terninals, f u s e blocks, signal transformer, current transformer, filament switching unit, track battery chargers, adjustable/fixed resistances, choke coils, Fuses, Relays, E type locks , termination of cables, cable insertion, wiring to draw 110V AC therefore in the new apparatus case a s required, testing, commissioning including subsequent alterations ( if required), bunching o f cables, earthing o f cable, 14 armours etc. Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anti -corrosive paint and subsequent two coatings of Alluminium paint outside and Red Oxide inside and lettering. 18 mm Hylum sheet for location box shelf and 12 mm for cable termination in location box. (c) Steel apparatus case (Quarter) to Drg.No. RE/S&T/Sig./Tender/SK / 5A/91 with 4 Nos. of SS foundation bolts of size 20mm x 300mm or latest.NOTE: - Payment can be released in a part for the above said work after completion of-(i) Foundation- 30%, (ii) Errection - 15% , (iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45% , (iv) Commissioning - 10% of the rate.

2

4266

8532

... More
Supply of Tool Kit for Multi Section Digital Axle Counter. Inspection by Rep. of Railway Engineer. (a)Fluke 289 or latest Digital multimeter of for MSDAC system with Probe set = One no. (b)Torque wrenches 25- 135 N/Mtr (c)Set of Spanners Screw driver and soldering iron suitable for MSDAC. (d)Dummy wheel (e)Marking Jig (f)Adapter Card (g)DAC EC Card Puller (h)Micro procceser based portable data analyser for down loading Event logger data for analysis and report generation for Digital Axle counter Model with (a) CPO-Intel Centrino Duo Moblie Technology with Intel Core 2 DUO Processor T 7200 or better 2 GHz, 4 MB L2 Cache of better. (b) Mother Board- Intel 945 GM/PM 6 Chipest. (c) Operating system- Preload with Vista Bussiness and free open Software.(d) Proccesar/Memory/System Bus- 667 MHz FSB or better,(e) Main Memory- DDR2-667 MHz (f) optical Drive-Intenal 8XDVD+/- RW Combination Drive (SuperMulti ) with dual layer write and read capabilities o r better with software, (g) Graphics Accelerator - Intel (R) Media Accelerator-950 Graphics:Upto 224 MB shared system memory, resolution 2048 X 1536, (h) Display- 15.4" TFT WXGA Display (1280 X 800 resolution) (i) Interfaces- IEEE 1394 integrated port (10/100/1000); 4* USB PORT + 1* Powered USB (D-Bay), 1* serial port RJ45 Ethernate port,RJ11 Morden port; external VGA port;Video: 15-pin moniter connector, Componet Video & Audio jacks;Built in Microphone;Bluetooth 2.0, (j) Wireless LAN - Intel (r) PRO /Wireless 3945. Network Connection 802.11 a/g Wi-Fi enabled., (k) Modem Internal 56 kbps or better,

2

140357

280714

... More
Collecting, stacking w i t h deployment o f M a n power, Hyd r a e t c f o r Loading/ 18 Unloading and Transportation of Materials (Fresh/Released/ Unused) from (i) work site to GSD/Raipur, (ii) work site to the stotre of SSE(SIG)/CON,(iii) any store depot to any other store depot over Indian railways as decided by Railway Administation by suitable Trucks and stacking properly.Here Job unit stands for TON-KM.

500

38

19000

... More
Supply of HP Color LJ Managed MFP E78228dn or similar printer. Inspection by Rep. of Railway Engineer.

3

224939

674817

... More
Shifting of cables in roll with or without wooden drums from other than nominated consignee depot and meggering before loading and after laying, and recording the values in cable insulation register along with representative of Railways. Here job unit stands for DRUM/Roll.

20

1282

25640

... More
Supply o f f u s e indication c u m monitoring a n d automatic changeover system a s p 7 e r RDSO specification no. RDSO/SPN/209/2012 Rev. 0 or latest. The system shall be supplied along with all standby fuses placed in the system. In addition to it, spare quantity of 100% fuses of each type shall also be supplied along with the system. Inspection by RDSO. For 32 fuses per set (Upto 4 Amps).

6

37882

227292

... More
Cable PVC insulated single core unsheathed with plain annealed copper conductor as 3 per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by Rep. of Railway Engineer. (d) Multi strand ISI copper cable (10 Sq.mm ) (Red-50%, Black-50% & Green-0%).

1

116166

116166

... More
Relay, AC Immune, plug-in type, Style "QNAI', Neutral line, 24V DC 12F.4B contacts, 2 front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23. The interlocking code for this unit shall be ABDFH . Inspection by RDSO.

100

4032

403200

... More
Cable PVC insulated single core unsheathed with plain annealed copper conductor as per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by Rep. of Railway Engineer. (c) 1x 4.0 sq mm flexible wire (Red-50%, Black-50% & Green-0%).

2

39683

79366

... More
Installation, cable termination, wiring, testing and commissioning of Auto Changeover panel.

21

6208

130368

... More
Design & Preparation of Circuits and drawings:- Design, Preparation & checking of documents and Circuit diagram and drawings :- k) Photocopy of various drawing in A3 size paper single side.

500

2

1000

... More
Physical tracing and opening/locating of existing working cables by precession digging for diversion of cables in connection with cable clearance for engineering earth work without interfering the circuits as per the advice of Railway site engineer.

50

241

12050

... More
Earthing and bonding system as per RDSO Spec. No. RDSO/SPN/197/2008 , RDSO Drg. No. SDO/RDSO/E&B/001 dt. 19.09.08 and RDSO Drg. No. SDO/RDSO/E&B/002 dt. 19.09.08. Earthing and bonding system for OFC room/FP/SSP etc. Inspection by RITES. (a) Supply of "Permanent and Maintenance Free Earth pits materials".1 Set PMF earth pit consisting of:- (i) 17 mm diameter and minimum 3 m long Copper Bonded Steel Rod- 3 Nos. (ii) GEM- 25 lb- 9 Bags (iii) 25*6*150 mm Cu bus bar ( At Electrode) - 1 No. (iv) 25*6*300 mm Cu Bus Bar ( MEBB) - 1 No (v) 25*6*150 mm Cu Bus Bar 9 (SEBB) - 3 Nos . (b) Supply for Interconnection of earthpits Copper Earth Tape of 25 x 2 mm (lump Sum 10 meter) (c) Supply for Connection between Earthpits and MEBB It includes 35 sq mm multi- strand pvc insulated single core Cu cable (15 mtr Lump Sum). (d) Supply for Internal connection from MEBB To SEBB and to other equipments.(50 mtr Lump Sum). It includes 16 sq mm and 10 sq mm pvc insulated single core Cu cable. (e) Cad weld Joints ( Exo thermic welding):- (i) For interconnection between earth pits - 3 Nos LS), (ii) Joint between Cu tape & electrode- 1 No LS, (iii) Connection between electrode to MEBB - 4 Nos LS, (iv) Between MEBB TO SEBB - 6 Nos LS, (f) Supply of fixing accessories as Cu lugs & steel nuts -bolts. 50 Nos. LS.

60

84458

5067480

... More
Laying of half round RCC hume pipe with 150 mm dia & 1 mtr long including supply at 9 site on single/multiple cable laid in the trench .NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no. 1 to 12 as mentioned above till commissioned.

50

254

12700

... More
Earth Electrodes to Drg. No: Con/SK/8/3/84. Inspection by Rep. of Railway Engineer

-

-

3

... More
Supply of IPS DC-DC converter 24-32V DC 10Amp. as per specification No. RDSO/SPN/165/2012, version-3.0 or latest. Make:M/s Statcon Ltd, compatable for the M/s Statcon IPS . Inspection by Rep. of Railway Engineer.

12

13676

164112

... More
Supply, installation testing commisssioing of UL/LPCB/VDS listed CPVC pipe 25 mm Dia & Pipe Accessories for the Aspiration detection. Approval - Ul and shall comply to RDSO spec. no. RDSO/SPN/217/2021 Ver 3.0 or latest. (Materials will be inspected by RITES)

1000

847

847000

... More
Non-deteriorating type low voltage electric fuse for Railway signalling, rated voltage 240 V AC/DC fuse with cylindrical cap without indication size :14x 51 mm. Spec. no: IRS-S-78/92 with latest amendment if any. Inspection by RDSO. (iii) 04 Amp fuse catridge

200

81

16200

... More
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning 3 etc., including bailing out water and disposal of extra soil. (ii) Hard rocky area including concreting.(b) Cutting the masonary wall to the depth of 0.25m to 0.75m at the entry of room placing of flexible HDPE pipe or G.I.Pipe (including supply) of suitable size as per drawing No. RE/S&T/ALD/SK/161/81.

4

582

2328

... More
ARA terminal for Signalling Installation with PBT materials . Inspection by RDSO. 6 Way (ARA terminal) Drg No.SA-23756 Alt3, Specn No. IRS-S-75/2006 (Rev.-2) with latest amd.

500

361

180500

... More
Supply of the following furnitures for SM / relay room. Inspection by Rep. of Railway Engineer.(a) Chair . Model PCH-5001T(Revolving) or latest. Make: Godrej or similar.

5

14405

72025

... More
Supply of MSDAC complete system (As per annex-A) with all accessories consisting of complete indoor and outdoor equipment including remote diagnostic and monitoring system as per 1 RDSO Specification no. RDSO/SPN/176/2013 Ver. 3 with the latest amendment/ revision of required Track Sections for entire yard as standby of DC track circuit in two stations : BEF and SGRD (home to home signals of each station). The MSDAC must be compatible with existing installed M/S Frauscher make MSDAC in SRGD and BEF. Inspection by RDSO. Here Job unit stands for DP.

35

342391

11983685

... More
Alteration/ Modifications in the existing location boxes, fixing of equipments, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same.

10

2548

25480

... More
Design & Preparation of Circuits and drawings:- Design, Preparation & checking of 1 documents and Circuit diagram and drawings :- c) Design and development of Station working rule Diagram (SWRD) based on SIP of station in size U(A3) as per SEM. Here job unit stands for Number of station.

2

5024

10048

... More
Q-series/Composite Relay Racks and cable termination racks (New).NOTE: Payment 1 can be released in a part for the above said work after completion of- (i) Errection- 15%, (ii) Wiring, testing, painting,earthing & writings etc - 75% , (iii)Commissioning of Relay rack/Composite rack/CTR- 10% of Schedule rate.

6

48363

290178

... More
Fuse Block for above fuse catridge, Spec. no: IRS-S-75/2006(rev-2) with latest amendment if any. Inspection by RDSO.

200

189

37800

... More
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. (iii) Track crossing, Road Crossing by pushing method (HDD method) at culverts/ track / pucca road crossing at a depth not less than 1 meter with reference to bottom of rail/road surface including supply of (b) GI pipe with 76 mm dia, Spec. No. -1239 medium grade (for the length of pushing more than 05 meters).

-

-

5

... More
2 Core Screened (sheilded ) cable size 16/0.20 mm(0.5 sq. mm. Whole) 650 volt grade as per specification No. IS 694/77 with jacket, make Empire or similar. Inspection by Rep. of Railway Engineer.

100

37

3700

... More
The excavation of pit, casting of concrete foundation including surrounding earthwork along the foundation, erection, installation and wiring of steel appartus ca se , fixing o f terninals, f u s 13 e blocks, signal transformer, current transformer, filament switching unit, track battery chargers, adjustable/fixed resistances, choke coils, Fuses, Relays, E type locks , termination of cables, cable insertion, wiring to draw 110V AC therefore in the new apparatus case a s required, testing, commissioning including subsequent alterations ( if required), bunching o f cables, earthing o f cable, armours etc. Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anti -corrosive paint and subsequent two coatings of Alluminium paint outside and Red Oxide inside and lettering. 18 mm Hylum sheet for location box shelf and 12 mm for cable termination in location box. (b) Steel apparatus case (half) with 4 Nos. o f S S foundation bolts 20mm x 460mm to Drg.No. SA-112 A/M or latest.NOTE: - Payment can be released in a part for the above said work after completion of-(i) Foundation- 30%, (ii) Errection - 15% , (iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45% , (iv) Commissioning - 10% of the rate.

2

8534

17068

... More
Supply of Analogue Addressable Multisensor Detector with multiple sensitivity( 10 adjustable at site) levels , programmable for timed automatic sensitivity selection with base, and other accessories as required and Detectors shall be dS/UL/FM/EN/LPCB listed. The Detectors shall comply to the RDSO/SPN/217/2016 Ver 3 or latest. Inspection by Rep. of Railway Engineer.

100

3712

371200

... More
Supply of Analog Type Linear Heat Sensing Cable (As per RDSO specification no. RDSO/SPN/217/2021 ver 3.0 or latest amendment). Inspection by Rep. of CSTE/CON/BSP.

1800

776

1396800

... More
Relay, Non-AC Immune, plug-in type, Style "QN1", Neutral line, 24V DC 12F.4B 1 contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:930, IRS:S 34 & IRS:S 23. The interlocking code for this unit shall be ABCDE. Inspection by RDSO.

100

3821

382100

... More
Design, Transportation, Installation, testing and commissioning of MSDAC complete system (As per annexure A) with all accessories consisting of complete indoor and outdoor equipment 2 including remote diagnostic and monitoring system as per RDSO Specification no. RDSO/SPN/176/2013 Ver. 3 with the latest amendment/revision of required Track Sections for entire yard as standby of DC track circuit of two stations (home to home signals of each station. Here Job unit stands for DP.

70

2352

164640

... More
Modification/Alteration of Data Logger/RTU Digital Input, validatory & yard simulation in both end station of IBS as per directive of Railway Representative .

6

43453

260718

... More
Installation, testing and commissioning of Permanent and Maintenance Free Earth pits .(For Copper Bonded Steel Rod- 3 Nos). Installation charges : Earthpit (1 Set) It includes, (i) Civil works related to earth pit digging, PMF earth pit installation,,backfilling and chamber making. (ii) Mateials for chamber including Chamber Cover. (iii) Drilling and fixing of MEBB & SEBB (iv) Installation for interconnection:-It includes civil work for 2 ft. depth x 1 ft.width trench digging and backfilling with GEM & Black soil. (10 mtr lump sum). Installation must be done as per RDSO Drg No. SDO/RDSO/E&B/001. The OEM shall be responsible for complete supply, installation & commissioning of the earthing & bonding system. The warranty of such system shall be 60 months from date of commissioning. During this period, any failure of earthing system due to improper materials & bad workmanship shall be attended free of cost by the OEM. OEM certificate will be issued by OEM after installation of earth.

-

-

4



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.