Rural Works Department Tender

... More
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

Rural Works Department - RWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date16 Apr 2024
Closing Date22 Apr 2024
Tender Amount₹ 4,70,06,545 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation for roadway in soil using manual means for carrying of out earth to embankment site with a lift up to 1.5 m and lead up to 50m as per Technical Specification Clause 302.3.SOR Item No.-3.5 (I)

33.9

6090

179.66

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5.SOR Item No.-3.3

23.73

1633

68.85

... More
Construction of embankment with approved material obtained from borrow pits with a lift up to 1.5m transporting to site, spreading grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead up to 1000 m as per Technical Specification Clause 301.5SOR Item No.-3.4

385.78

99917

259

... More
Construction of embankment with approved material obtained from borrow pits with a lift up to 1.5m transporting to site, spreading grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead up to 100 m as per Technical Specification Clause 301.5SOR Item No.-3.5 (ii)

96.44

17707

183.61

... More
Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.SOR Item No.-3.15 (ii)

958.37

251610

262.54

... More
Construction of granular sub-base by providing well graded material (Grading I) , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with three wheel 80-100 kN static roller capacity to achieve the desired density, complete as per Technical Specification Clause 401SOR Item No.-4.1.401(Aii)

277.21

1092179

3939.9

... More
WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.80 -100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.SOR Item No.-4.7 (3)(A)

195.44

1009402

5164.77

... More
Prime Coat Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502SOR Item No.-5.1 (i)

1158.98

69990

60.39

... More
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 50SOR Item No.-5.2 (iii) 503

1158.98

24014

20.72

... More
Mix Seal Surfacing (Waste Plastic) By Mechanical Means (Type-B) Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509SOR Item No.-5.11

1158.98

341678

294.81

... More
Cement Concrete Pavement Construction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501SOR Item No.-6.4

231.49

2198317

9496.38

... More
Laying brick soling layer on prepared sub-grade with brick on end edging according to lines, graded and cross-section shown on the drawing filling joints with sand and earth, spreading 25 mm thick layer of earth over brick soling, watering and rolliing the same with three wheel road roller 80-100 kN as per Technical Specification Clause 412SOR Item No.-4.18

382

178149

466.36

... More
Earthwork excavation for foundation of structures as per drawing and teachnical specification clause 1104 includding setting out, stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved matefial . (A)Ordinary soil SOR Item No.-11.1 (I)

176.36

72425

410.66

... More
Providing concrete for plain/reinforced concrete in opne foundations complete as per drawwings and technical specifications clause 802,803,1202&1203 (I) PCCGrade M-10 Nominal mix 1:2.5:5 with 40 mm and down graded metelSOR Item No.-11.4(II) (i)

13.24

114122

8618.84

... More
Providing concrete for plain/reinforced concrete in opne foundations complete as per drawwings and technical specifications clause 802,803,1202&1203 (I) PCCGrade M-15 Nominal mix 1:2.5:5 with 40 mm and down graded metelSOR Item No.-11.4(II) (i)

33.27

273862

8231.02

... More
Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications clauses 600,1202&1203SOR Item No.-11.5(II)

-

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 PCC M15SOR Item No.-11.4 (II)

49.02

403484

8231.02

... More
Providing concrete for plain/reinforced concrete (M-20 Nominal mix 1:2:4) in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Bed Portion SOR Item No.-11.4 (III)

5.22

46902

8985.24

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 P.C.C grade M 15

20.17

171878

8519.79

... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Cllauses 1002,1010 and 1202 (8.10 + 4.84)SOR Item No.-13.2

0.41

36101

88267.41

... More
Brick masonry work in cement mortar 1:3 in parapet excluding pointing and plastering as per drawing and technical specifications clauses 600,900 and 1208.4SOR Item No.-13.9

11.72

84152

7180.24

... More
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification clauses 613.4 & 1204SOR Item No.-12.3

106.72

27122

254.15

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new plasted / concrete surface as per drawing and technical specification clause 1701

40.32

5131

127.28

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8SOR Item No.-12.10

85.29

81436

954.85

... More
Providing weepholes in brick masonry/stone mosonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification clauses 616,709,1204.3.7SOR Item No.-12.90

32

4728

147.75

... More
Guide PostSOR Item No.-

16

11397

712.35

... More
RCC GRADE M-25 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204

9.99

97043

9714.09

... More
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 @ @ 100 kg/cum of RCC + 80 kg/cum of PCC of cutoff wall

1.18

95250

80789.35

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

19.98

86179

4312.42

... More
Drainage spouts complete as per drawing and technical specifications clause 1209SOR Item No.-13.10

4

3268

817.2

... More
RCC M-25 Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5

4.09

43156

10541.29

... More
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3

5

33238

6647.67

... More
Bedding for Type - B PCC(M20) Bedding Laying (First Class ) bedding concrete as per clause 1105 (ii)SOR Item No.-9.2

1.58

908

574.77

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 1000 mm dia as per design in Single Row SOR Item No.-9.3

15

108360

7224.03

... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Manual Means Plain Cement Concrete SOR Item No.-2.5 I (B)

1.54

1014

658.99

... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Manual Means Reinforced Cement Concrete SOR Item No.-2.5 I (C)

0.76

1253

1649.22

... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Manual Means Rubble stone masonry in cement SOR Item No.-2.5 III (B)

59.41

27765

467.35

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. Upto 600 mm dia Hume pipeSOR Item No.-2.13 A

10

2487

248.74

... More
Providing and laying reinforced cement concrete pipe NP4 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapaets clause 1106. SOR Item No.-9.3(C)

22.5

18956

842.5

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 SOR Item No.-(I)(II) Ordinary Kilometer Stone (Pre-cast)

1

3292

3292.45

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 SOR Item No.-10.1(III) 200m Stone (Pre-cast)

3

2707

902.37

... More
Boundary Pillar Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704At outer side of H-Curve & @ 1.50m c/c both side at heigh embankment SOR Item No.-10.11

10

7123

712.35

... More
Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 SOR Item No.-10.16

2

29867

14933.84

... More
Maintenance Board

1

14933

14933.84

... More
MMGSY Logo Board

1

14933

14933.84

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1)(ii) 600 mm equilateral triangle

6

26589

4431.63

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1)(vii) 900 mm side octagon

2

19139

9569.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1)(Viii) Speed Limit (600 MM Circular)

4

22456

5614.14

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1) (v) 600 mm x 450 mm rectangular

2

11133

5566.77

... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 . The finished surface to be level , uniform and free from streaks and holes. SOR Item No.-8.13

61.2

47828

781.51

... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 . The finished surface to be level , uniform and free from streaks and holes. Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt dust oil grease efflorescence and applying @ of 1 liter for 2 sqm.

76.4

67222

879.87

... More
Rumble Strips (Provision of 15 nos rumble strips covered with MSS bituminous carpet, 15-20 mm high at center, 250 mm wide placed at 1 m center to center at approved locations to control speed, marked with white strips of road marking paint.)

28.13

8291

294.81

... More
Rumble Strips - Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 . The finished surface to be level , uniform and free from streaks and holes.

28.13

21979

781.51

... More
Planting of Trees and their Maintenance for one Year Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one

15

18865

1257.72

... More
Add 1% Labour Cess

1

74793

74793

... More
Add 18% GST

1

1346279

1346279

... More
Add 10% Seigniorage Fee

1

96430

96430

... More
Maintainance for 1st year

1

28324

28324

... More
Maintainance for 2nd year

1

37044

37044

... More
Maintainance for 3rd year

1

174497

174497

... More
Maintainance for 4th year

1

73369

73369

... More
Maintainance for 5th year

1

200397

200397

... More
Add 1% Labour Cess

1

5136

5136

... More
Add 18% GST

1

92454

92454

... More
Add 10% Seigniorage Fee

1

823

823

... More
SBI Bank to Manitola - Setting out(i) Construction of Reference & Working Benchmark = 2 Nos. & 6 Nos. RespectivelySOR Item No.-1.16

1.3

7336

5656.77

... More
(ii) Construction of Reference Pillars/Burjees = 52 NosSOR Item No.-1.16

1.3

3442

2654.37

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.SOR Item No.-2.2

0.39

28352

72697.86

... More
Excavation for roadway in soil using manual means for carrying of out earth to embankment site with a lift up to 1.5 m and lead up to 50m as per Technical Specification Clause 302.3.SOR Item No.-3.5 (I)

109.37

19649

179.66

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5.SOR Item No.-3.3

76.56

5271

68.85

... More
Construction of embankment with approved material obtained from borrow pits with a lift up to 1.5m transporting to site, spreading grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead up to 1000 m as per Technical Specification Clause 301.5SOR Item No.-3.4

1572.14

407184

259

... More
Construction of embankment with approved material obtained from borrow pits with a lift up to 1.5m transporting to site, spreading grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead up to 100 m as per Technical Specification Clause 301.5SOR Item No.-3.5 (ii)

393.04

72166

183.61

... More
Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.SOR Item No.-3.15 (ii)

611.27

160482

262.54

... More
Construction of granular sub-base by providing well graded material (Grading I) , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with three wheel 80-100 kN static roller capacity to achieve the desired density, complete as per Technical Specification Clause 401SOR Item No.-4.1.401(Aii)

162.55

827080

5088.16

... More
WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.80 -100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.SOR Item No.-4.7 (3)(A)

283.2

1900790

6711.83

... More
Cement Concrete Pavement Construction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501SOR Item No.-6.4

788.23

8611050

10924.54

... More
Laying brick soling layer on prepared sub-grade with brick on end edging according to lines, graded and cross-section shown on the drawing filling joints with sand and earth, spreading 25 mm thick layer of earth over brick soling, watering and rolliing the same with three wheel road roller 80-100 kN as per Technical Specification Clause 412SOR Item No.-4.18

1297

604868

466.36

... More
Earthwork excavation for foundation of structures as per drawing and teachnical specification clause 1104 includding setting out, stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved matefial . (A)Ordinary soil SOR Item No.-11.1 (I)

343.45

141040

410.66

... More
Providing concrete for plain/reinforced concrete in opne foundations complete as per drawwings and technical specifications clause 802,803,1202&1203 (I) PCCGrade M-10 Nominal mix 1:2.5:5 with 40 mm and down graded metelSOR Item No.-11.4(II) (i)

23.7

239123

10088.32

... More
Providing concrete for plain/reinforced concrete in opne foundations complete as per drawwings and technical specifications clause 802,803,1202&1203 (I) PCCGrade M-15 Nominal mix 1:2.5:5 with 40 mm and down graded metelSOR Item No.-11.4(II) (i)

99.82

952316

9540.72

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 P.C.C grade M 15

60.52

594900

9829.49

... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Cllauses 1002,1010 and 1202 (8.10 + 4.84)SOR Item No.-13.2

1.23

108871

88729.44

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8SOR Item No.-12.10

55.52

53014

954.85

... More
Providing weepholes in brick masonry/stone mosonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification clauses 616,709,1204.3.7SOR Item No.-12.90

96

14336

149.34

... More
RCC GRADE M-25 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204

29.97

334639

11165.81

... More
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 @ @ 100 kg/cum of RCC + 80 kg/cum of PCC of cutoff wall

3.54

287373

81247.88

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

59.95

341985

5704.33

... More
Drainage spouts complete as per drawing and technical specifications clause 1209SOR Item No.-13.10

12

9806

817.2

... More
RCC M-25 Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5

12.28

147276

11991.26

... More
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3

15

99715

6647.67

... More
Bedding for Type - B PCC(M20) Bedding Laying (First Class ) bedding concrete as per clause 1105 (ii)SOR Item No.-9.2

1.58

908

574.77

... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Manual Means Plain Cement Concrete SOR Item No.-2.5 I (B)

0.69

454

658.99

... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Manual Means Reinforced Cement Concrete SOR Item No.-2.5 I (C)

7.56

12468

1649.22

... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Manual Means Rubble stone masonry in cement SOR Item No.-2.5 III (B)

74.25

34700

467.35

... More
Providing and laying reinforced cement concrete pipe NP4 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapaets clause 1106. SOR Item No.-9.3(C)

22.5

22174

985.53

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 SOR Item No.-(I)(II) Ordinary Kilometer Stone (Pre-cast)

2

7291

3645.99

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 SOR Item No.-10.1(III) 200m Stone (Pre-cast)

5

4830

966

... More
Boundary Pillar Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704At outer side of H-Curve & @ 1.50m c/c both side at heigh embankment SOR Item No.-10.11

19

14092

741.71

... More
Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 SOR Item No.-10.16

2

30527

15263.88

... More
Maintenance Board

1

15263

15263.88

... More
MMGSY Logo Board

1

15263

15263.88

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1)(ii) 600 mm equilateral triangle

12

55159

4596.65

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1)(vii) 900 mm side octagon

2

19469

9734.66

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1)(Viii) Speed Limit (600 MM Circular)

4

23116

5779.16

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1) (v) 600 mm x 450 mm rectangular

2

11463

5731.79

... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 . The finished surface to be level , uniform and free from streaks and holes. Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt dust oil grease efflorescence and applying @ of 1 liter for 2 sqm.

259.4

228238

879.87

... More
Rumble Strips (Provision of 15 nos rumble strips covered with MSS bituminous carpet, 15-20 mm high at center, 250 mm wide placed at 1 m center to center at approved locations to control speed, marked with white strips of road marking paint.)

28.13

9148

325.29

... More
Rumble Strips - Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 . The finished surface to be level , uniform and free from streaks and holes.

28.13

21979

781.51

... More
Add 1% Labour Cess

1

164986

164986

... More
Add 18% GST

1

2969754

2969754

... More
Add 10% Seigniorage Fee

1

162320

162320

... More
Maintainance for 1st year

1

10644

10644

... More
Maintainance for 2nd year

1

12472

12472

... More
Maintainance for 3rd year

1

238882

238882

... More
Maintainance for 4th year

1

12472

12472

... More
Maintainance for 5th year

1

238882

238882

... More
Add 1% Labour Cess

1

5134

5134

... More
Add 18% GST

1

92403

92403

... More
Add 10% Seigniorage Fee

-

-

-

... More
Narkatiaganj Gaunaha Road to Sitwapur- Setting out(i) Construction of Reference & Working Benchmark = 2 Nos. & 6 Nos. RespectivelySOR Item No.-1.16

1.38

7644

5543.24

... More
(ii) Construction of Reference Pillars/Burjees = 55 NosSOR Item No.-1.16

1.38

3577

2594.54

... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.SOR Item No.-2.2

0.41

29806

72697.86

... More
Excavation for roadway in soil using manual means for carrying of out earth to embankment site with a lift up to 1.5 m and lead up to 50m as per Technical Specification Clause 302.3.SOR Item No.-3.5 (I)

120.53

21654

179.66

... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5.SOR Item No.-3.3

84.37

5808

68.85

... More
Construction of embankment with approved material obtained from borrow pits with a lift up to 1.5m transporting to site, spreading grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead up to 1000 m as per Technical Specification Clause 301.5SOR Item No.-3.4

1679.78

435063

259

... More
Construction of embankment with approved material obtained from borrow pits with a lift up to 1.5m transporting to site, spreading grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead up to 100 m as per Technical Specification Clause 301.5SOR Item No.-3.5 (ii)

419.94

77105

183.61

... More
Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.SOR Item No.-3.15 (ii)

721.83

189509

262.54

... More
Construction of granular sub-base by providing well graded material (Grading I) , spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with three wheel 80-100 kN static roller capacity to achieve the desired density, complete as per Technical Specification Clause 401SOR Item No.-4.1.401(Aii)

396.68

1861020

4691.49

... More
WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.80 -100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.SOR Item No.-4.7 (3)(A)

391.72

2419803

6177.38

... More
Prime Coat Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502SOR Item No.-5.1 (i)

2158.88

130892

60.63

... More
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 50SOR Item No.-5.2 (iii) 503

2158.88

44904

20.8

... More
Mix Seal Surfacing By Mechanical Means (Type-B) Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509SOR Item No.-5.11

2158.88

680155

315.05

... More
Cement Concrete Pavement Construction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501SOR Item No.-6.4

490.25

5113881

10431.17

... More
Laying brick soling layer on prepared sub-grade with brick on end edging according to lines, graded and cross-section shown on the drawing filling joints with sand and earth, spreading 25 mm thick layer of earth over brick soling, watering and rolliing the same with three wheel road roller 80-100 kN as per Technical Specification Clause 412SOR Item No.-4.18

809

377285

466.36

... More
Earthwork excavation for foundation of structures as per drawing and teachnical specification clause 1104 includding setting out, stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved matefial . (A)Ordinary soil SOR Item No.-11.1 (I)

92.82

38117

410.66

... More
Providing concrete for plain/reinforced concrete in opne foundations complete as per drawwings and technical specifications clause 802,803,1202&1203 (I) PCCGrade M-10 Nominal mix 1:2.5:5 with 40 mm and down graded metelSOR Item No.-11.4(II) (i)

8.01

76741

9580.69

... More
Providing concrete for plain/reinforced concrete in opne foundations complete as per drawwings and technical specifications clause 802,803,1202&1203 (I) PCCGrade M-15 Nominal mix 1:2.5:5 with 40 mm and down graded metelSOR Item No.-11.4(II) (i)

-

-

-

... More
Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications clauses 600,1202&1203SOR Item No.-11.5(II)

-

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 PCC M15SOR Item No.-11.4 (II)

73.53

668260

9088.27

... More
Providing concrete for plain/reinforced concrete (M-20 Nominal mix 1:2:4) in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Bed Portion SOR Item No.-11.4 (III)

7.83

77628

9914.3

... More
Brick masonry work in cement mortar 1:3 in parapet excluding pointing and plastering as per drawing and technical specifications clauses 600,900 and 1208.4SOR Item No.-13.9

8.94

65536

7330.71

... More
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification clauses 613.4 & 1204SOR Item No.-12.3

99.6

26723

268.31

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8SOR Item No.-12.10

100.17

95647

954.85

... More
Guide PostSOR Item No.-

24

17557

731.57

... More
Bedding for Type - B PCC(M20) Bedding Laying (First Class ) bedding concrete as per clause 1105 (ii)SOR Item No.-9.2

1.58

908

574.77

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 1000 mm dia as per design in Single Row SOR Item No.-9.3

22.5

167766

7456.3

... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Manual Means Plain Cement Concrete SOR Item No.-2.5 I (B)

1.54

1014

658.99

... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Manual Means Reinforced Cement Concrete SOR Item No.-2.5 I (C)

0.76

1253

1649.22

... More
Dismantling of Structures Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. By Manual Means Rubble stone masonry in cement SOR Item No.-2.5 III (B)

59.41

27765

467.35

... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. Upto 600 mm dia Hume pipeSOR Item No.-2.13 A

10

2487

248.74

... More
Providing and laying reinforced cement concrete pipe NP4 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapaets clause 1106. SOR Item No.-9.3(C)

22.5

21062

936.12

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 SOR Item No.-(I)(II) Ordinary Kilometer Stone (Pre-cast)

2

7047

3523.86

... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 SOR Item No.-10.1(III) 200m Stone (Pre-cast)

5

4720

944.02

... More
Boundary Pillar Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704At outer side of H-Curve & @ 1.50m c/c both side at heigh embankment SOR Item No.-10.11

21

15362

731.57

... More
Providing and fixing of typical MMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 SOR Item No.-10.16

2

30299

15149.86

... More
Maintenance Board

1

15149

15149.86

... More
MMGSY Logo Board

1

15149

15149.86

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1)(ii) 600 mm equilateral triangle

10

45396

4539.64

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1)(vii) 900 mm side octagon

2

19355

9677.65

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1)(Viii) Speed Limit (600 MM Circular)

8

45777

5722.15

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 SOR Item No.-10.2 A (1) (v) 600 mm x 450 mm rectangular

2

11349

5674.78

... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 . The finished surface to be level , uniform and free from streaks and holes. SOR Item No.-8.13

114

89092

781.51

... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 . The finished surface to be level , uniform and free from streaks and holes. Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt dust oil grease efflorescence and applying @ of 1 liter for 2 sqm.

161.8

142362

879.87

... More
Rumble Strips (Provision of 15 nos rumble strips covered with MSS bituminous carpet, 15-20 mm high at center, 250 mm wide placed at 1 m center to center at approved locations to control speed, marked with white strips of road marking paint.)

28.13

8860

315.05

... More
Rumble Strips - Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 . The finished surface to be level , uniform and free from streaks and holes.

28.13

21979

781.51

... More
Planting of Trees and their Maintenance for one Year Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one

29

36473

1257.72

... More
Add 1% Labour Cess

1

131950

131950

... More
Add 18% GST

1

2375093

2375093

... More
Add 10% Seigniorage Fee

1

165001

165001

... More
Maintainance for 1st year

1

42023

42023

... More
Maintainance for 2nd year

1

58658

58658

... More
Maintainance for 3rd year

1

332736

332736

... More
Maintainance for 4th year

1

127872

127872

... More
Maintainance for 5th year

1

382038

382038

... More
Add 1% Labour Cess

1

9433

9433

... More
Add 18% GST

1

169799

169799

... More
Add 10% Seigniorage Fee

1

1533

1533



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.