With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

Northeast Frontier Railway - NFR Tender

Works
Telecommunication Services
Ireps
Opening Date25 Sep 2024
Closing Soon18 Oct 2024
Tender Amount₹ 11,99,85,308.36 
Notes
Download

Costs

Summary

Supply Of Materials, Laying, Protection, Jointing & Termination Of Ofc And Quad Cable, Installation Of Associated Equipment In 5 Stations Of Kir-kdpr And 6 Stations Of Kir-mfa

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Straight through Jointing Kit (TSF-1) for 20-pair armoured PIJF cable - as per Spec No RDSO/SPN/TC/57/2015 Rev 1 or latest - To be procured from RDSO approved firm

30

507

15210

... More
1-Quad 2-T VF Transformer (1120:470) - for derivation jointing kit for 6 Quad cable - as per Spec No IRS:TC-76/2000 Amd-1 or latest. To be procured from RDSO approved firm

70

877

61390

... More
Optical fibre joint enclosure - for 24 fibre armoured underground OFC - with all accessories and consumables. Make: Rekam/3M/ Commscope or similar.

30

2624

78720

... More
20 pair Krone cable distribution box - consisting of Krone metal connection box No 07 6901-1-50001, back mount frame (LSA plus krone make) and 2/10 disconnection module (LSA plus krone) - as approved by Engineer-in-charge - as per Spec No GR/CTN-01/04 May 2005 or latest. Make: ADC/ Krone or similar.

30

972

29160

... More
Permanently lubricated HDPE pipe of size 33/40 mm nominal - along with socket - as per RDSO Specification No RDSO/ SPN/ TC/ 45/ 2013 Rev 2.0 or latest or TEC specification TEC/ GR/ TX/ CDS-008/ 03, March-11 or latest

38

45934

1745492

... More
Permanently lubricated HDPE pipe of size 63 mm (outer dia) with minimum wall thickness of 3mm - along with socket - as per Spec No RDSO/SPN/TC/45/2013 Rev 2.0 or latest

8000

208

1664000

... More
HDPE DWC pipe of size 110/94 mm dia nominal - as per RDSO Specification No. 10 RDSO/SPN/204/2011 version 1.1 Amd. 1 or latest TEC specification No. with Anti Rodent and Anti- flammable property - along with socket, coupler etc. - as per technical specification and as approved by Engineer-in-charge

3

239239

717717

... More
DTMF Based Telephone 2 wire, 9-12V - as per RDSO Specification No IRS : TC / 80 - 2000 Amd-3 or latest - for party line working. To be procured from RDSO approved firm

25

2788

69700

... More
Smart RFID marker - electronic marker with 1.5m or higher detection range & unique ID code for unique detection - Ball type Passive Marker. Make: 3M/Stanley or equivalent. To be supplied only after approval of competent authority

350

1918

671300

... More
RFID marker locator with provision for cable route and fault locator - 1.5m or higher 13 depth range, digital display, GPS module, memory for storing marker records - including training of duration, as approved by Engineer-in-charge - includes supply of marker database software for database management of installed markers. Make: 3M/Stanley or similar. To be supplied only after approval of competent authority

2

303476

606952

... More
Supply of Galvanized Iron Trunking with cover of same material as per Drawing No. SWG/ NGS/ C7/ 91.

700

1191

833700

... More
Earth electrode for outdoor equipment conventional earthing as per Dwg. No.RVNL/S7T/SC/12/2015 or latest or as approved by Engineer in charge.

25

1911

47775

... More
Supply of station telephone (MASTER) of electronic LC gate communication system as per RDSO specification No. RDSO/SPN/TC/51/2011(rev.3.0) with voice logging facility, surge protection & line connection unit and centralised power supply system with battery.

15

46738

701070

... More
24 V DC power supply unit with MF battery for electronic LC gate telephone system as per RDSO specification No. RDSO/SPN/TC/51/2011 rev. 3.0

15

6416

96240

... More
Supply of Gate telephone ( Slave) with surge protection and line connection unit as per RDSO specification No. RDSO/SPN/TC/51/2011 rev.3.0

35

5454

190890

... More
Programmable primary digital drop insert multiplexer with conference facility - 01 complete with dual power supply, control and basic accessories cards - as per IRS-TC-68-2012 Amd1 or latest - excluding channel interface cards - includes supply of DAC card or its equivalent, if data acquisition not in-built

8

64472

515776

... More
VF / E&M card, 2W/4W programmable - as per IRS-TC-68-2012 or latest - subject to minimum of 4 cct per card

40

15298

611920

... More
2W Exchange loop interface card with ringer - as per IRS-TC-68-2012 or latest - subject to minimum of 4 cct per card

5

11949

59745

... More
2W Subscriber loop interface card with ringer - as per IRS-TC-68-2012 or latest - subject to minimum of 4 cct per card 05

10

16727

167270

... More
DAC Card with all accessiories - as per IRS-TC-68/ 2012 or latest 07

6

30637

183822

... More
TME/ Ethernet Card - as per IRS-TC-68/ 2012 or latest 08

6

40386

242316

... More
Control communication equipment (CRE) - complete with remote patching equipment (RPE) for OFC using 2 wire telephone, control room equipment - as per RDSO Spec No RDSO/SPN/TC/66/2007 Amd 3 or latest - from RDSO approved manufacturer, if any

1

225378

225378

... More
Control communication equipment (TRE) - complete with local telephone equipment (LTE) for OFC using 2 wire telephone, test room equipment - as per RDSO Spec No RDSO/SPN/TC/66/2007 Amd 3 or latest - from RDSO approved manufacturer, if any

1

208733

208733

... More
Control communication equipment for OFC using 2 wire telephone way station equipment (MTWE) - as per RDSO Spec No RDSO/SPN/TC/66/2007 Amd 3 or latest - from RDSO approved manufacturer, if any

8

122353

978824

... More
Control communication Equipments for OFC, using 2 wire telephone, 3 way Amplifier (TWA) - suitable for working with control Room equipment & wayside equipment - as per RDSO Spec No RDSO/SPN/TC/66/2007 Amd 3 or latest - from RDSO approved manufacturer, if any

2

19113

38226

... More
Covered racks - 42U size - Steel Body - Complete with all fittings for STM, MUX, 4 No DC cooling fan including wiring and other accessories - Make: Rittal/ Valrack/ APW President or similar.

6

48725

292350

... More
Supply & Installation of Fiber distribution management system including complete 14 accessiories - for 48 fibers armored UG OF Cable (24 fibers from each side), suitable for termination in 19" Rack- includes supply of all pig tail/ patch cord, splicing of patch cords/pig tails and other associated works with SC-SC Connector. Make: Commscope/ 3M.

12

23799

285588

... More
50 pair Krone cable distribution box - with locking arrangement - consisting of Krone 15 metal connection box No 6901-1-50002 , back mount frame (LSA plus krone make) and 2/10 disconnection module (LSA plus krone) - as approved by Engineer-in-charge - as per Spec No GR/CTN- 01/04 May 2005 or latest

12

3293

39516

... More
100 pair Krone cable distribution box - with locking arrangement - consisting of Krone metal connection box, back mount frame (LSA plus krone make) and 2/10 disconnection module (LSA plus krone) - as approved by Engineer-in-charge - as per Spec No GR/CTN-01/04 May 2005 or latest

12

4781

57372

... More
Krone type termination modules - with accessories & Surge and Lightening protection (Z-protection) -complete for all 30 channels derived from PDMUX - as per technical specification

12

6859

82308

... More
48 V 200 AH VRLA battery bank - shelf supported - as per IRS-S-93/96 Amd 1 or latest. To be procured from RDSO approved firms

6

113771

682626

... More
Supply & installation of a srt of Class B and Class C Surge Protection Device - indicative type - for protection of Telecomm Devices working on 230V Ac at OFC Room and ASM Room as per RDSO/SPN/TC/98/2011 Rev. 0 or latest

6

27395

164370

... More
SMPS based battery charger - 25A SMR[2+1]-Rectifier module, 230V / 48 V DC 50 A - as per Spec No RDSO/SPN/TL/23/99 Ver 4 Amd1 or latest - with potential free contacts for remote monitoring. To be procured from RDSO approved firms

6

104076

624456

... More
Patch Cord - each 5M length, with SC-SC (APC) or SC-PC (UPC) connector at both end - as per Spec No TEC/GR/TX/OFJ-01/05 Nov 2009 or latest

50

538

26900

... More
Switch Board cable 10 pair 0.5mm dia - make Bentor or superior, as approved by Engineer-in-charge - as per IRS TC/24/91 or latest - each coil of 90M

15

4882

73230

... More
Switch Board cable 20 pair 0.5mm dia - make Bentor or superior, as approved by Engineer-in-charge - as per IRS TC/24/91 or latest - each coil of 90M

15

9016

135240

... More
4G based FCT phone - with provision for Caller ID. Make: Beetel or Panasonic or Motorola. Details in TS

10

2886

28860

... More
Quad Cable link cut monitoring unit - complete with audio visual indication for break / cut of Quad cable - Make Bentron or superior, as approved by Engineer-in-charge

12

36799

441588

... More
Lead Acid Secondary cell 12V/120AH maintenance free VRLA - Make Exide or Amaron or Okaya, as approved by Engineer-in-charge

8

8829

70632

... More
Fully Automatic Splicing machine - as per Spec No TEC/GR/TX/OSM-001/04/SEP-12 or 28 latest - Make: FUJIKURA FSM 80S or FITEL FURUKAWA S178A V.2 or Similar Models with all accessiories like 3 in 1 stripper, high precision cleaver, AC adapter with cable cord, Battery pack, spare electrode, software CD, hard carrying case, PC interface cable, cleaning brush, electrode sharpener, user manual

1

512617

512617

... More
OTDR - as per Spec No TEC/GR/TX/OTD-01/04/APR-2010 or latest - Make: VIAVI MTS- 6000 or Yokogawa AQ-7280 + AQ-7284A or Similar Models

1

466507

466507

... More
CTDR : TDR based Cable fault locator for metallic cables [S&T cables] - range upto 15 Km - Make: 3M or Stanley or as approved by Engineer-in-charge

1

153525

153525

... More
Digital Multimeter - True RMS type - Make Fluke / Benning/ Meco/ Kyoritsu. Details as per TS

10

9804

98040

... More
TMS Kit- as per Spec No.IRS TC-43/87 or latest- Aplab 2031A or superior, as approved by Engineer-in-charge.

6

21797

130782

... More
Cross Talk Measuring Set Type 378-A - as per IRS TC-45/88 or latest - Anu vidyut or superior, as approved by Engineer-in-charge

2

42406

84812

... More
Digital Insulation Tester - as approved by Engineer-in-charge - Make Fluke /Megger /Meco / Hioki. Details as per TS

10

31994

319940

... More
Earth Resistance Meter - as approved by Engineer-in-Charge. Make: Fluke /Benning/ Megger/ Kyoritsu. Details as per TS

2

14885

29770

... More
Handheld E1 and Ethernet Tester BER for testing of E1, Ethernet and STM-1 with specification as per TS. Make: Viavi Model No. MTS-4800P or similar model of Sunrise Telecomm/ Stanlay. Details as per TS

2

263536

527072

... More
PC based Portable Work Station - for configuration and testing of SDH and PDH equipments, Routers etc. with specification as per TS. Make: Dell XPS 13 9300 or similar model of HP/ Microsoft, Details as per TS with NMS software as per TS

4

88595

354380

... More
Desktop based Work Station - for Data input, configuration and functional testing with specification as per TS. Make: Dell/ HP/ Lenovo,Spectra or similar Spec as per TS.

2

110170

220340

... More
External Solid State Drive (SSD) - Portable - 1 TB Capacity as per TS. Make: Seagate/ Samsung/ Sandisk

4

14786

59144

... More
Multi function Color Laser Printer with Scanning facility - Make HP Laserjet Pro MFP M479dw or similar model of HP/ Canon/ Epson

4

71799

287196

... More
Supply of system connectivity for BPAC working on OFC,with 2-E1 and 8 channel including 19 inch rack mountable interface module as per technical specification make MROTEK or similar( One pair consists of two nos. equipment required for a single block section)

16

90336

1445376

... More
Krone connection / disconnection tool

20

4045

80900

... More
Supply of PVC insulated single core, unsheathed copper conductor, flexible 10 sq. mm, Finolex make product code 14208 (colour red and blackin 1:1 ratio) or latest. (Coil of 100mtrs)

5

9866

49330

... More
Survey and preparation of the mapping of the cable route diagrams consisting of existing signaling, telecom and other cables and proposed Quad and OFC cable route with reference to old cable and railway boundary duly showing drain / bridge /culvert / retaining wall / road crossing / track crossing / HDD location. Final documentation: 1) Orignial documents of all particulars of cable 01 laying should be handed over to Engineer-in-charge after all the works are completed 2) Basis above, 12 No of hard copies and 2 No of soft copies in pen-drives shall be prepared covering the following items broadly - cable route plan, cable laying particular, jointing location 3) Standard schematic diagram for cable termination details at way station, STM1 circuits etc. to be prepared and handed over as hard copies (12 No) and soft copies (2 No - pen drives) 4) Completion documents (hard copy in 12 sets along with soft copies) should be supplied within 1 month of commisioning of station; post 1 month of commisioning

-

-

96500

... More
Digging of 1.2 M deep and 0.3 M wide trench - including clearing of roots of trees and bushes and temporary obstruction on the selected route - as per technical specification and cable 02 route plan - includes back filling and ramming of the soil in trench to original level - in all type of soil Note: In case where digging of trench up to 1.2 M deep and 0.3 M wide is not possible, depth can be reduced / increased only with approval of Engineer-in-charge and post confirmation of railway representative at site, duly recorded in the field book (payment will be decreased / increased proportionate to the depth & width of excavation as compared to 1.2 M deep and 0.3 M wide)

25

48993

1224825

... More
Excavation of cable trench 1.0 M deep, 0.3 M wide on pucca road / platform / track- crossing - includes placing of GI pipe, re-filling the trench and ramming - includes restoration of road / 03 platform / ballast to the original condition - includes supply of GI pipe (80 mm nominal bore, thickness 4mm, outside dia 88-89.5mm - specification No. IS 1239 (Pt-1) 1990 or latest - with thread collars; medium grade) and all other materials required for execution of work, but not included in schedule elsewhere 04

300

397

119100

... More
Laying of 6 Quad / PIJF cable - as per cable route plan; in the already dug trench - as per TS

32000

2

64000

... More
Blowing / Pulling of 24 fiber OFC, with Nylon rope, through HDPE pipe of size 40/33 mm - includes filling of boring pit, if any - as approved by Engineer-in-charge and as per TS

36000

4

144000

... More
Protection of under ground cable by provision of concrete layer in the ratio 1:2:4 - minimum thickness - 100mm and minimum width - 200mm

1500

284

426000

... More
Protection work of cable over boulder pitched / high cutting area, in yard, rocky, 08 congested / residential area using 100 mm nominal dia RCC pipe and covering it making continuous square block of 1:2:3 masonry work as per site condition. The RCC pipe will be supplied by the contractor

1000

213

213000

... More
Digging of 1.20 meter deep and 0.3 meter wide trenches including clearing of roots of trees and bushes and temporary obstruction on the selected route as per technical specification and cable route plan in hard/ballast mixed soils

300

346

103800

... More
Excvation of trenches upto depth of 1 mtr at katcha road/under low flooded bridges/ culverts/ low laying areas or as advised by the site incharge of the railway and placing of DWC pipe of size 110/94mm with sockets. 11

3000

143

429000

... More
Transportation of HDD machine with accessories including handling of stores materials preparation of site and boring (Boring size to accomodate two HDPE pipes of 40mm and 63mm outer dia) for placing and laying of S&T cables through HDPE pipe. Boring trench shall be minimum 3(three) 12 meter below the river bed and minimum 1.5 (One point five) meter below surface in other patches.This item includes supply of HDPE pipes (of outer dia 40mm and 63mm) with RDSO/SPN/TC/45/2013 Rev. 2 or latest specification, minimum wall thickness 3mm with IP 67 protection with socket or coupler, having anti rodent properties and should be fire retardent to TEC specification with accessories for HDPE pipe. Cost of fuel, jointing of pipes, if required and all other items which will be required for laying cable through HDPE pipe. This also includes laying of cables through boring. NOTE: 1. Work to be carried out as per instruction of site engineer. 2. HDPE pipe will be inspected by RITES (for value of materials equal or more than 5 Lakh Rupees) or Consignee (for value of materials less than 5 Lakh Rupees). Contractor shall submit Test Certificate from Original Manufacturer of HDPE pipes. 3. Payment will be made as per actual work done. Size: 110mm Boring upto the length of 150m

7000

887

6209000

... More
Installation of OFC Joint enclosure - includes splicing of Optic Fiber cable (24 fiber) along with testing, as per technical specification - jointing to be done in presence of railway representative; testing to be done jointly with division

20

2517

50340

... More
Provision of RCC pit - 1M below earth surface, with arrangement for entry and exit of HDPE pipe - as per Dwg No NF/TC/99-25 or latest - after laying of OFC, RCC pit shall be filled with sand and covered with suitable RCC covering slab

20

2738

54760

... More
Installation of thermoshrink jointing kit for 6 Quad cable - as per DOT/TEC specification (with RDSO modification for straight through joints) - as per technical specification - jointing to be done in presence of railway representative; testing to be done jointly with division

40

991

39640

... More
Provision of derivation joint - at approx every 1 Km (location as approved by Engineer- 16 in-charge) for emergency sockets and LC gates - using PIJF cable, thermo shrink jointing kit and 2T VF transformer - jointing to be done in presence of railway representative; testing to be done jointly with division

30

1481

44430

... More
Installation of straight through jointing kit - for PIJF cable - as per RDSO code of practice for PIJF jointing using thermo shrink joints - jointing to be done in presence of railway representative; testing to be done jointly with division

10

487

4870

... More
Fixing of 100/50/20 pair CT Box Krone type - includes termination of PIJF cable in ASM Room, Cable Hut, LC gate and other buildings - as per instructions of Engineer-in-charge and as per details in approved wiring / jointing schedule

40

395

15800

... More
Supply & Erection of Concrete Emergency post - as per Drg No SK/2004/00005 or 19 latest - includes transportation to site, digging of pit and erection of emergency post (complete with socket and socket box) - as per specification & drawing - includes wiring, testing and commissioning along side the Railway Track (at locations indicated by Engineer-in-charge) - does not include supply of emergency socket and emergency socket box

40

2004

80160

... More
Painting of telephone marking along with arrow mark - indicating the direction of 20 nearest emergency socket on hectometer posts installed alongside the railway track - enamel paint flourescent type (Asian / Berger or superior) should be used - dimensions to be got approved from Engineer-in-charge prior to commencement of work

300

17

5100

... More
Supply, transportation to site, erection & concreting the base of RCC Cable route 21 marker - for marking along the cable route / track crossing / road crossing for OFC and Quad cable - as per Dwg No NF/TC/99-23 or latest and as approved by Engineer-in-charge - painting on RCC route marker to be got approved from Engineer-in-charge prior to commencement of work

300

201

60300

... More
Transportation to site and installation of Smart RFID Electronic Cable Marker - at location of OFC joints and at other locations as per instructions of Engineer-in-charge - includes - includes supply of RFID co-ordinates, as read by RFID locator, in soft [2 No] and hard copies [2 No]

300

93

27900

... More
Testing of all the fibers of the optical fiber cable - before laying & after completion of laying and termination of cable in required location - includes all tests as detailed in technical specification - includes supply of all test reports, jointly signed with division

5

9222

46110

... More
Loading, transportation & unloading etc of cable drums, and other materials required for execution of work at site, from store to work site - as per instructions of Engineer-in-charge 26 48.00 Vehicle- 26

70000

6

420000

... More
Hiring of two MUVs during pre-work survey and during execution of work for two years 3000 KM X 720 hours 24x7 non AC.

3011359.68

3011359

3011359.68

... More
Fixing of GI Trunking on girder bridges including supply of channel angle iron bracket 27 unit,nuts and bolts of proper sizes and fitting of support at an intervel of one meter including laying of cable inside the troughs and filling with bitumen compound as per specification n. IRS:TC-25/76 after cable is laid, bitumen and other materials as required for the work shall be supplied by the contractor.

700

404

282800

... More
Installation, Testing and Commissioning of station telephone (MASTER) of electronic LC 28 gate communication system as per RDSO specification No. RDSO/SPN/TC/51/2011(rev.3.0) with voice logging facility, surge protection & line connection unit and centralised power supply system with battery.

12

17133

205596

... More
Installation, Testing and Commissioning of 24 V DC power supply unit with MF battery for electronic LC gate telephone system as per RDSO specification No. RDSO/SPN/TC/51/2011 rev. 3.0

15

2492

37380

... More
Installation, Testing and Commissioning of Gate telephone ( Slave) with surge protection and line connection unit as per RDSO specification No. RDSO/SPN/TC/51/2011 rev.3.0

15

2398

35970

... More
Installation and commissioning of Add / Drop Mux, Primary digital drop insert multiplexer - with all accessories and power supply, surge & lightening protection arrangement, racks, 01 runway ladder etc. - in station / cable huts / test room - includes wiring of all the equipments upto Krone / CT Box / FDMS, including "U" links for derivation cables / OFC - includes fixing / installation of FDMS - as per station requirement - includes issue of OEM certificate, checklist (jointly signed with division) and training of duration as approved by Engineer-in-charge

6

19887

119322

... More
Supply and installation of MDF frame for accomodation of 100 pair Krone - includes all necessary wiring, all necessary wiring materials to be supplied by firm (if not included in schedule elsewhere)

12

8893

106716

... More
Supply and fixing of Quad cable termination box - includes termination of Quad cable 03 in ASM room on Wago / Disconnect terminals - or as per approval of Engineer-in-charge - includes supply of all necessary materials i.e. teakwood board (or superior quality wood as approved by Engineer-in-charge)

6

14500

87000

... More
Installation, testing and commissioning on OFC channels of control room equipment, 04 way side equipment, ADM and Control phone, FCT Phone - as per TS - includes wiring/termination, supply of all materials required (but not covered in schedule elsewhere) and restoration of surface / flooring / wall etc. to original condition

6

1450

8700

... More
Installation, wiring and commissioning of Battery chargers & VRLA batteries - at each OFC installation, as per technical specification - includes supply and provision of ladder, DC power supply distribution system, wiring etc.

6

3648

21888

... More
Installation and commissioning of Quad cable link monitoring unit with battery - 06 includes supply of all wiring materials, teakwood (or superior quality wood, as approved by Engineer- in-charge) etc. required for execution of work, but not covered in schedule elsewhere - includes issue of OEM certificate, checklist (jointly signed with division) and impart of training of duration, as approved by Engineer-in-charge

10

8737

87370

... More
Testing and final commissioning of all the equipments - in each station, conforming with the approved system design - includes end to end testing for realization of optical fiber system as per technical specification

6

59364

356184

... More
Digital Platform Clock- double side with GPS synchronization - as per RDSO Specification. 02

14

95935

1343090

... More
Supply of 3-core X 2.5 sq. mm multi strand power cable confirming the TS no.IS:694:1990 reaffirmed 1995 0r latest.

2500

74

185000

... More
Online UPS - 2 KVA Capacity - for GPS Synchronised Clocks, as per TS. Make: APC/ Microtek/ Luminous

8

38454

307632

... More
Installation and commissioning of Digital Clocks - GPS Synchronized Platform and Office Clocks - by metal clamps at Platforms as per requirement and as advised by Engineer - in - Charge - as per TS 06

6

7961

47766

... More
Rack 19 inch 27U - Floor Mounted - Steel body - with 4 Nos trays, cooling fan complete with cables and power manager. Make: Rittal/ Valrack/ APW President 08

6

22913

137478

... More
Microphone with cord - Make: Ahuja, Model No. 99MS or similar 09

12

1165

13980

... More
PA Horn Speakers - 25 Watt - Make: Ahuja, Model No. UHC-25 with line matching transformer or similar 11

20

1534

30680

... More
Inverter - Pure Sine Wave Output - 800 VA Capacity - for PA system. Make: Luminous/ Microtek/ Amaron/ Exide

7

8144

57008

... More
VRLA Battery - 12V, 150 AH Capacity - suitable for Inverters. Make: Exide/ Amaron/ Okaya 14

7

15670

109690

... More
Supply & fixing of 1.5 inch casing capping with all fitting materials. 15

4000

70

280000

... More
Supply & fixing of 1 inch conduit pipe (3m long) with all fitting materials 16

6000

72

432000

... More
Installation, testing & commissioning of complete Manual PA System with all accessories viz. Amplifiers,Racks,Microphones,Horn speakers,Power System, UPS and Battery etc. 18

6

1445

8670

... More
Counter communication system. Make: Ahuja or similar 19

12

9967

119604

... More
Router 8 LAN, 08x2Mbps WAN V.35 with required cables and accessories, AC Power supply. Make: Cisco

2

293980

587960

... More
Router 4 LAN, 04x2Mbps WAN V.35 with required cables and accessories, AC Power supply. Make: CISCO

5

249475

1247375

... More
24 port Layer-2, 10/100 PROGRAMMABLE switch, with cables and accessories, AC power supply. Make: Cisco 24

7

34517

241619

... More
Modem G.703 - 2 Mbps. Make: MROTEK/ Cygnus/ Team Link 25

18

10541

189738

... More
Rack 19 inch 9-U - Steel Body - Wall Mounted - with cooling fans. Make: Rittal/ Valrack/ APW President 27

6

5311

31866

... More
CAT-6 cable - 24AWG 100Mhz. Make: DLINK 28

16

5532

88512

... More
RJ-45 Connector 29

200

7

1400

... More
RJ-45 LAN Cable 30

50

87

4350

... More
Wiring of CAT 6 cable through conduit pipe or casing caping 31

1000

6

6000

... More
Supply and Installation- Media Converter 10/100/ 1000 Mbps Single Mode Fiber. Make: DLINK/ TEAM ENGINNER/ MROTEK 33

4

11980

47920

... More
Installation of PRS /UTS Terminal Repeater Universal Model includes fixing of Terminal Repeater with clamping arrangement as per direction of site supervisor,all materials to be supplied by the contractor.

12

580

6960

... More
Installation of Routers, switch & modems etc. for PRS/UTSas per instruction of site supervisor.

6

9109

54654

... More
Supply and intallation of self supported Telescopic mast up to 15 meter Height as per TS including lightening spike at the top.

6

61175

367050

... More
A set of complete earthing system, maintenance free tripod type consisting of Copper 02 rod as per RDSO/SPN/197/2016 or equivalent size strip, electrode with welded connecting rod and extension , copper cable for connection, Chemical earthing with ultra efficient Gel having earth impedance 1 ohm for filling around earth electrode.

12

50817

609804

... More
Installation,carrying out necessary digging work for fixing earth electrode in ground, Commissioning of complete earthing system,maintenance free tripod type consisting of copper rod/strip,extension,cable connections,filling around earth electrode chemical Earthing with ultra efficient Gel having earth impedance 1 ohm,all work of earthing as per standard practice and connecting it to equipments to be earthed, supply and providing copper earth lead wires multistrand lead wires, exothermic bonding with contractor,s materials all connections between earth electrodes and earthing, one end to earth electrode and the other end of the wire to block equipment, power 03 equipment, cable sheath, signals etc. as per requirements & technical specification. 04

12

6359

76308

... More
Power supply 12V DC/20 Amps of reputed make . 05

7

6126

42882

... More
Battery (12V,120AH of reputed make like EXIDE or superior. 06

7

13492

94444

... More
25 W VHF Radio(Motorola/Kenwood ) make. 07

7

28559

199913

... More
Omni directional stacked Dipole Antena SWR less than 1.5 . 08

7

16277

113939

... More
Installation and commissioning of VHF system-complete with all accessories and power supply.

6

4672

28032

... More
Foundation for erection of self supported mast 15 meter high as per drg. Approved by Engineere in charge and as per TS

6

29530

177180

... More
Supply and Installation of polished wooden rack to accommodate 12V 120 AH battery and charger - of teakwood or superior quality wood, as approved by Engineer in charge of dimension.

6

7414

44484

... More
Supply of Standard 19" Rack Mountable LER ( Label Edge Router), IP-MPLS Router with Redundant DC power feed- 48 V DC nominal, equipped with interfaces: 2X10 G (Optical) SFP + ports along with 2 Nos. of 40 Kms 10 G SFP + LC Modules, 4X1 GbE (Opticasl) interface along with 4 Nos. of 01 1 GbE Single Mode Bi-directional SFP ( 10 KMs) Modules and 4X1 GbE ( Copper) based interfaces & Modules, 2X STM-1( Channelised) interfaces along with 2 Nos. of SFP ( S.1.1) Modules compatible with Existing STM-1,and slot for 16X E1 ( G. 703), {supply of 16 E 1 card is not included in this item } , Mounting kit with all necessary accessories & software, perpetual Licenses. Asd per RDSO Document No. STT/TAN/IP-MPLS/2020 Version 01 or latest. Inspection : RDSO

4

545560

2182240

... More
Supply of Standard 19" Rack Mountable Modular Chasis LSR ( Label Switch Router) IP- 02 MPLS Router with Redundant DC power feed- 48 V DC nominal,Redundant Controller Card, equipped with interfaces: 8X10 G (Optical) SFP + ports along with 8 Nos. of 40 Kms 10 G SFP + Modules, Mounting kit with all necessary accessories & software, perpetual Licenses. Asd per RDSO Document No. STT/TAN/IP-MPLS/2020 Version 01 or latest. Inspection : RDSO

2

1391314

2782628

... More
Installation,Commissioning & Testing of LER & LSR IP MPLS Routers including supply & 03 installation of all the accessories like power cable, Earthing cable, Optical Patch Cords of 3 mtr- 4 Nos. for LER & 8 Nos. for LSRs, CAT-6 patch cords of 1 mtr- 4 Nos, one 6 A MCB for each LER and LSR, wiring etc. as required for Routers.

5

73674

368370

... More
Supply and installation of 16 port E1 card along with patch panel /krone Module and wiring for Routers with all accessories etc. Inspection RDSO.

15

108289

1624335

... More
Supply, installation, testing and commissioning of Standard 19- inch Rack Mountable Layer 3, 24 ports Managed Switch with 24 Nos. of 10/100/1000 Ethernet Ports with POE + Support and 05 Redundant AC power Supply, Dedicated Stacking Module 4 X 10 GE SFP + Ports for uplink including 4 Nos. of 10 GE BX SM SFP + Modules, as per para Number 4.0 of RDSO Specification No. RDSO/SPN/TC/83/2020 Rev 2 or latest.Mounting kit with all necessary accessories to be supplied as per TS. Inspection RDSO

6

184477

1106862

... More
Supply of 8 X 1 G Adapter Interface ( any combination : one nos. of 8 X 1 G or two nos. of 4 X 1 G ) without SFP for LER Routers. Inspection RDSO.

2

63463

126926

... More
Supply of 2 X STM 1 Adapter Interface with 2 Nos. of STM-1, 20-25 Km, SFP modules for LER Routers, Inspection RDSO 09

2

247711

495422

... More
Supply of 10 G SFP+ Module with 40 Km range for above Routers.Inspection RDSO 10

2

132564

265128

... More
Supply of STM-1 SFP Module with 15 Km range with all accessories for above Routers. Inspection RDSO

2

9512

19024

... More
Supply of 10/100/1000 Base -T Copper Ethernet Transceiver SFP Module with all accessories. Inspection RDSO

2

6269

12538

... More
Supply of 12 Core Metal StrengthenedOutdoor Unarmoured Optic Fibre Cable(ITUTG- 652-D) and all the accessoriesrequired for installation, as per latestTEC/BSNL Specification as per TS. Inspection: RITES

500

11

5500

... More
Supply and Termination of 12 Fiber 12SC Type Rack Mountable FDMS loaded withSC '0' DB & Adaptor SC SM Pigtail1.5 meters with all the accessories required for installation as per TS. Inspection: RITES

6

7551

45306

... More
Supply of Single Mode Patch Cord length3 meters (LC-SC/SC-SC/LC-LC/FC-LC)as per site requirement, as per TS.Inspection: Consignee

25

604

15100

... More
Supply of STP CAT- 6 Cable compliantwith latest EIA/TIA-568-B-2-1 StandardforCAT 6 Cable 305 Meters Roll /Bundle. As Per TS, Inspection:RITES

610

27

16470

... More
Supply of PVC insulated 3 Core 6Sqmm,12 AWG 12.1 KV Grade Outdoor Strengthen Copper cable. As per TS.Inspection: Consignee.

700

165

115500

... More
Splicing /Dropping/Termination of each Fiber /Pigtail in the LIU/FDMS/Termination Joints through fusion Splicing of the termination of OFC Cables. As per Ts

200

37

7400

... More
Supply and installation of SIP Based Basic IP Phone with 128x64 Pixel Graphical LCD as per Specification.Inspection RITES

10

5294

52940

... More
Supply and Installation of Control IPTelephones with Hands Free and Gooseneck Operation for Way Side Station as Per Clause 11 of RDSO/SPN/TC/99/2012 Rev.2 or lates.AS per TS Inspection RDSO

10

18804

188040

... More
Wiring and Termination for IP Phones upto last point (includes configuring, fixing of I/O box, Drawing of UTP/OF Cable,Fixing of PVC Pipe /Casing capping. All miscellaneous materials required for fixing to be supplied by Contractor as per site requirement.

6

48130

288780

... More
Supply of SIP Based Medium IP Phone with 240X120 Pixel or better Graphical LCD with Backlight, Minimum 8 No of One Touch line key as per TS.Inspection RITES

6

12816

76896

... More
Supply of Portable Maintenance Terminal (Similar to Laptop) as Per Clause No 8.7 and 8.9 RDSO/SPN/TC/99/2012 Rev.2 as per TS.

2

74220

148440

... More
Supply, Installation and Commissioning of Test Room Console as Per Clause 10 of RDSO/SPN/TC/99/2012 Rev. 2 or latest,AS per TS. Inspection: RDSO

1

441880

441880

... More
Supply, Installation and Commissioning of 4 Port Gateway to support 4 Port Concurrent 08 Emergency Communication at HQ/Way station to support 4 wire ports/ 4 Port Gateway with built in 2 wires to 4 wire Hybrid convertor to support 4 wire output as Per Clause 13 of RDSO/SPN/TC/99/2012 Rev.2 or latest. AS per TS. Inspection: RDSO

6

46668

280008

... More
Supply and installation of Station License of TCCS communication Server of 1+2 configuration as per RDSO/SPN/TC/99/2012 Rev.2. Inspection:RDSo

6

17222

103332

... More
Supply and installation of Port License of TCCS communication Server of 1+2 configuration as per RDSO/SPN/TC/99/2012 Rev.2. Inspection:RDSo

6

2222

13332

... More
Supply, Installation and Commissioning of Network Management Server as per Clause 5 and 8 RDSO/SPN/TC/99/2012 Rev.2 or latest as per TS.Inspection :RDSO

1

461384

461384

... More
Supply, Installation and Commissioning of Voice Recording Server as per Clause 5 and 7RDSO/SPN/TC/99/2012 Rev.2 or latest as per TS.Inspection :RDSO

1

704820

704820

... More
Supply, Installation and Commissioning of Event Notification Gateway as perClause12.3 of RDSO/SPN/TC/99/2012Rev.2 or latest, as per TS.Inspection: RDSO

1

250953

250953

... More
Supply, Installation and Commissioningof Desktop Client PC As per clause 8.7and 8.8 of RDSO/SPN/TC/99/2012 Rev.2 or latest along with 600VA UPS as per TS.

1

65630

65630

... More
Supply of 24 Port FXO Gateway 19" Rack mountable suitable for 96/48 FXS Gateway chassis along with patch panel/krone module. (AC or DC based) including mounting kit and all the accessories. As per TS. Inspection:Consignee

1

60902

60902

... More
Supply of DTMF Gateway 4 port as per clause 12 of RDSO/SPN/TC/99/2012 Rev 2 or latest.

1

78594

78594

... More
Supply, Installation And commissioning of Communication server as per clause 5 and 6 of RDSO/SPN/TC/99/2012 Rev.2 oe latest. Total 2 servers, 1 at main location and one at remote location

2

1981180

3962360

... More
6-pin Emergency socket - as per RDSO Specification No IRS-TC-42/87 Amd-3 or latest - flat type. To be procured from RDSO approved firm

60

153

9180

... More
Emergency socket box FRP type - as per RDSO Specification No RDSO/SPN/TC/44/2002 Ver-2 Amd-1 to 3 or latest. To be procured from RDSO approved firm

50

4115

205750

... More
hermoshrink Jointing Kit -(TSF-4) for 6 Quad 0.9mm jelly filled cable - as per RDSO Specification No IRS: TC-77/2012 Rev-3 Amd-3 or latest - for derivation 2T & straight through joints. To be procured from RDSO approved firm

65

2036

132340

... More
Straight through Jointing Kit (TSF-1) for 20-pair armoured PIJF cable - as per Spec No RDSO/SPN/TC/57/2015 Rev 1 or latest - To be procured from RDSO approved firm

40

507

20280

... More
1-Quad 2-T VF Transformer (1120:470) - for derivation jointing kit for 6 Quad cable - as per Spec No IRS:TC-76/2000 Amd-1 or latest. To be procured from RDSO approved firm

80

877

70160

... More
20 pair Krone cable distribution box - consisting of Krone metal connection box No 07 6901-1-50001, back mount frame (LSA plus krone make) and 2/10 disconnection module (LSA plus krone) - as approved by Engineer-in-charge - as per Spec No GR/CTN-01/04 May 2005 or latest. Make: ADC/ Krone

40

972

38880

... More
Permanently lubricated HDPE pipe of size 33/40 mm nominal - along with socket - as per RDSO Specification No RDSO/ SPN/ TC/ 45/ 2013 Rev 2.0 or latest or TEC specification TEC/ GR/ TX/ CDS-008/ 03, March-11 or latest

42

45934

1929228

... More
Permanently lubricated HDPE pipe of size 63 mm (outer dia) with minimum wall thickness of 3mm - along with socket - as per Spec No RDSO/SPN/TC/45/2013 Rev 2.0 or latest

8000

208

1664000

... More
HDPE DWC pipe of size 110/94 mm dia nominal - as per RDSO Specification No. 10 RDSO/SPN/204/2011 version 1.1 Amd. 1 or latest or TEC specification. with Anti Rodent and Anti- flammable property - along with socket, coupler etc. - as per technical specification and as approved by Engineer-in-charge

3

239239

717717

... More
DTMF Based Telephone 2 wire, 9-12V - as per RDSO Specification No IRS : TC / 80 - 2000 Amd-3 or latest - for party line working. To be procured from RDSO approved firm

35

2788

97580

... More
Smart RFID marker - electronic marker with 1.5m or higher detection range & unique ID code for unique detection - Ball type Passive Marker. Make: 3M or Stanley. To be supplied only after approval of competent authority

400

1918

767200

... More
RFID marker locator with provision for cable route and fault locator - 1.5m or higher 13 depth range, digital display, GPS module, memory for storing marker records - including training of duration, as approved by Engineer-in-charge - includes supply of marker database software for database management of installed markers. Make: 3M Model No. Dynatel 2573E-ID/CU12 or Stanley make similar model. To be supplied only after approval of competent authority

2

303476

606952

... More
Supply of Galvanized Iron Trunking with cover of same material as per Drawing No. SWG/ NGS/ C7/ 91.

1000

1191

1191000

... More
Earth electrode for outdoor equipment conventional earthing as per Dwg. No.RVNL/S7T/SC/12/2015 or latest or as approved by Engineer in charge.

30

1911

57330

... More
Supply of station telephone (MASTER) of electronic LC gate communication system as per RDSO specification No. RDSO/SPN/TC/51/2011(rev.3.0) with voice logging facility, surge protection & line connection unit and centralised power supply system with battery.

15

46738

701070

... More
24 V DC power supply unit with MF battery for electronic LC gate telephone system as per RDSO specification No. RDSO/SPN/TC/51/2011 rev. 3.0

15

6416

96240

... More
Supply of Gate telephone ( Slave) with surge protection and line connection unit as per RDSO specification No. RDSO/SPN/TC/51/2011 rev.3.0

35

5454

190890

... More
Programmable primary digital drop insert multiplexer with conference facility - 01 complete with dual power supply, control and basic accessories cards - as per IRS-TC-68-2012 Amd1 or latest - excluding channel interface cards - includes supply of DAC card or its equivalent, if data acquisition not in-built

10

64472

644720

... More
VF / E&M card, 2W/4W programmable - as per IRS-TC-68-2012 or latest - subject to minimum of 4 cct per card

40

15298

611920

... More
2W Subscriber loop interface card with ringer - as per IRS-TC-68-2012 or latest - subject to minimum of 4 cct per card 05

15

16727

250905

... More
E1 Branching Card - for 3rd direction E1 branching - as per IRS-TC-68/2012 or latest 06

2

15433

30866

... More
DAC Card with all accessiories - as per IRS-TC-68/ 2012 or latest 07

6

30637

183822

... More
TME/ Ethernet Card - as per IRS-TC-68/ 2012 or latest 08

6

40386

242316

... More
Control communication equipment (CRE) - complete with remote patching equipment (RPE) for OFC using 2 wire telephone, control room equipment - as per RDSO Spec No RDSO/SPN/TC/66/2007 Amd 3 or latest - from RDSO approved manufacturer, if any

1

225378

225378

... More
Control communication equipment (TRE) - complete with local telephone equipment (LTE) for OFC using 2 wire telephone, test room equipment - as per RDSO Spec No RDSO/SPN/TC/66/2007 Amd 3 or latest - from RDSO approved manufacturer, if any

1

208733

208733

... More
Control communication equipment for OFC using 2 wire telephone way station equipment (MTWE) - as per RDSO Spec No RDSO/SPN/TC/66/2007 Amd 3 or latest - from RDSO approved manufacturer, if any

7

122353

856471

... More
Control communication Equipments for OFC, using 2 wire telephone, 3 way Amplifier (TWA) - suitable for working with control Room equipment & wayside equipment - as per RDSO Spec No RDSO/SPN/TC/66/2007 Amd 3 or latest - from RDSO approved manufacturer, if any

2

19113

38226

... More
Covered racks - 42U size - Steel Body - Complete with all fittings for STM, MUX, 4 No DC cooling fan including wiring and other accessories - Make: Rittal/ Valrack/ APW President

6

48725

292350

... More
Supply & Installation of Fiber distribution management system including complete 14 accessiories - for 48 fibers armored UG OF Cable (24 fibers from each side), suitable for termination in 19" Rack- includes supply of all pig tail/ patch cord, splicing of patch cords/pig tails and other associated works with SC-SC Connector. Make: Commscope/ 3M.

10

23799

237990

... More
50 pair Krone cable distribution box - with locking arrangement - consisting of Krone 15 metal connection box No 6901-1-50002 , back mount frame (LSA plus krone make) and 2/10 disconnection module (LSA plus krone) - as approved by Engineer-in-charge - as per Spec No GR/CTN- 01/04 May 2005 or latest

10

3293

32930

... More
100 pair Krone cable distribution box - with locking arrangement - consisting of Krone metal connection box, back mount frame (LSA plus krone make) and 2/10 disconnection module (LSA plus krone) - as approved by Engineer-in-charge - as per Spec No GR/CTN-01/04 May 2005 or latest

15

4781

71715

... More
Krone type termination modules - with accessories & Surge and Lightening protection (Z-protection) -complete for all 30 channels derived from PDMUX - as per technical specification

15

6859

102885

... More
48 V 200 AH VRLA battery bank - shelf supported - as per IRS-S-93/96 Amd 1 or latest. To be procured from RDSO approved firms

7

113771

796397

... More
Supply & installation of a srt of Class B and Class C Surge Protection Device - indicative type - for protection of Telecomm Devices working on 230V Ac at OFC Room and ASM Room as per RDSO/SPN/TC/98/2011 Rev. 0 or latest

7

27395

191765

... More
SMPS based battery charger - 25A SMR[2+1]-Rectifier module, 230V / 48 V DC 50 A - as per Spec No RDSO/SPN/TL/23/99 Ver 4 Amd1 or latest - with potential free contacts for remote monitoring. To be procured from RDSO approved firms

7

104076

728532

... More
Switch Board cable 10 pair 0.5mm dia - make Bentor or superior, as approved by Engineer-in-charge - as per IRS TC/24/91 or latest - each coil of 90M

15

4882

73230

... More
Switch Board cable 20 pair 0.5mm dia - make Bentor or superior, as approved by Engineer-in-charge - as per IRS TC/24/91 or latest - each coil of 90M

15

9016

135240

... More
Push button telephone - suitable for connecting with control room equipment and wayside equipment - with provision for Caller ID for ADM Phone. Make: Beetel/ Panasonic/ Motorola

30

1095

32850

... More
4G based FCT phone - with provision for Caller ID. Make: Beetel or Panasonic or Motorola. Details in TS

10

2886

28860

... More
Quad Cable link cut monitoring unit - complete with audio visual indication for break / cut of Quad cable - Make Bentron or superior, as approved by Engineer-in-charge

12

36799

441588

... More
Lead Acid Secondary cell 12V/120AH maintenance free VRLA - Make Exide or Amaron or Okaya, as approved by Engineer-in-charge

8

8829

70632

... More
Fully Automatic Splicing machine - as per Spec No TEC/GR/TX/OSM-001/04/SEP-12 or 28 latest - Make: FUJIKURA FSM 80S or FITEL FURUKAWA S178A V.2 or Similar Models with all accessiories like 3 in 1 stripper, high precision cleaver, AC adapter with cable cord, Battery pack, spare electrode, software CD, hard carrying case, PC interface cable, cleaning brush, electrode sharpener, user manual

1

512617

512617

... More
OTDR - as per Spec No TEC/GR/TX/OTD-01/04/APR-2010 or latest - Make: VIAVI MTS- 6000 or Yokogawa AQ-7280 + AQ-7284A or Similar Models

1

466507

466507

... More
CTDR : TDR based Cable fault locator for metallic cables [S and T cables] - range upto 15 Km - Make: 3M or Stanley or as approved by Engineer-in-charge

1

153525

153525

... More
Digital Multimeter - True RMS type - Make Fluke / Benning/ Meco/ Kyoritsu. Details as per TS

15

9804

147060

... More
TMS Kit- as per Spec No.IRS TC-43/87 or latest- Aplab 2031A or superior, as approved by Engineer-in-charge.

6

21797

130782

... More
Cross Talk Measuring Set Type 378-A - as per IRS TC-45/88 or latest - Anu vidyut or superior, as approved by Engineer-in-charge

2

42406

84812

... More
Digital Insulation Tester - as approved by Engineer-in-charge - Make Fluke /Megger /Meco / Hioki. Details as per TS

10

31994

319940

... More
Earth Resistance Meter - as approved by Engineer-in-Charge. Make: Fluke /Benning/ Megger/ Kyoritsu. Details as per TS

2

14885

29770

... More
Handheld E1 and Ethernet Tester BER for testing of E1, Ethernet and STM-1 with specification as per TS. Make: Viavi Model No. MTS-4800P or similar model of Sunrise Telecomm/ Stanlay. Details as per TS

2

263536

527072

... More
PC based Portable Work Station - for configuration and testing of SDH and PDH equipments, Routers etc. with specification as per TS. Make: Dell XPS 13 9300 or similar model of HP/ Microsoft, Details as per TS with NMS software as per TS

6

88595

531570

... More
Desktop based Work Station - for Data input, configuration and functional testing with specification as per TS. Make: Dell/ HP/ Lenovo,Spectra or similar Spec as per TS.

3

110170

330510

... More
External Solid State Drive (SSD) - Portable - 1 TB Capacity as per TS. Make: Seagate/ Samsung/ Sandisk

4

14786

59144

... More
Multi function Color Laser Printer with Scanning facility - Make HP Laserjet Pro MFP M479dw or similar model of HP/ Canon/ Epson

4

71799

287196

... More
Supply of system connectivity for BPAC working on OFC,with 2-E1 and 8 channel including 19 inch rack mountable interface module as per technical specification make MROTEK or similar( One pair consists of two nos. equipment required for a single block section) 42

16

90336

1445376

... More
Supply of PVC insulated single core, unsheathed copper conductor, flexible 10 sq. mm, Finolex make product code 14208 (colour red and blackin 1:1 ratio) or latest. (coil of 100 mtrs)

5

9866

49330

... More
Survey and preparation of the mapping of the cable route diagrams consisting of existing signaling, telecom and other cables and proposed Quad and OFC cable route with reference to old cable and railway boundary duly showing drain / bridge /culvert / retaining wall / road crossing / track crossing / HDD location. Final documentation: 1) Orignial documents of all particulars of cable 01 laying should be handed over to Engineer-in-charge after all the works are completed 2) Basis above, 12 No of hard copies and 2 No of soft copies in pen-drives shall be prepared covering the following items broadly - cable route plan, cable laying particular, jointing location 3) Standard schematic diagram for cable termination details at way station, STM1 circuits etc. to be prepared and handed over as hard copies (12 No) and soft copies (2 No - pen drives) 4) Completion documents (hard copy in 12 sets along with soft copies) should be supplied within 1 month of commisioning of station; post 1 month of commisioning

-

-

112500

... More
Digging of 1.2 M deep and 0.3 M wide trench - including clearing of roots of trees and bushes and temporary obstruction on the selected route - as per technical specification and cable 02 route plan - includes back filling and ramming of the soil in trench to original level - in all type of soil Note: In case where digging of trench up to 1.2 M deep and 0.3 M wide is not possible, depth can be reduced / increased only with approval of Engineer-in-charge and post confirmation of railway representative at site, duly recorded in the field book (payment will be decreased / increased proportionate to the depth & width of excavation as compared to 1.2 M deep and 0.3 M wide)

29

48993

1420797

... More
Excavation of cable trench 1.0 M deep, 0.3 M wide on pucca road / platform / track- crossing - includes placing of GI pipe, re-filling the trench and ramming - includes restoration of road / 03 platform / ballast to the original condition - includes supply of GI pipe (80 mm nominal bore, thickness 4mm, outside dia 88-89.5mm - specification No. IS 1239 (Pt-1) 1990 or latest - with thread collars; medium grade) and all other materials required for execution of work, but not included in schedule elsewhere 04

300

397

119100

... More
Laying of 6 Quad / PIJF cable - as per cable route plan; in the already dug trench - as per TS

36000

2

72000

... More
Blowing / Pulling of 24 fiber OFC, with Nylon rope, through HDPE pipe of size 40/33 mm - includes filling of boring pit, if any - as approved by Engineer-in-charge and as per TS

40000

4

160000

... More
Protection of under ground cable by provision of concrete layer in the ratio 1:2:4 - minimum thickness - 100mm and minimum width - 200mm

1500

284

426000

... More
Protection work of cable over boulder pitched / high cutting area, in yard, rocky, 08 congested / residential area using 100 mm nominal dia RCC pipe and covering it making continuous square block of 1:2:3 masonry work as per site condition. The RCC pipe will be supplied by the contractor

1000

213

213000

... More
Digging of 1.20 meter deep and 0.3 meter wide trenches including clearing of roots of 09 trees and bushes and temporary obstruction on the selected route as per technical specification and cable route plan in hard/ballast mixed soils

300

346

103800

... More
Excvation of trenches upto depth of 1 mtr at katcha road/under low flooded bridges/ culverts/ low laying areas or as advised by the site incharge of the railway and placing of DWC pipe of size 110/94mm with sockets. 11

3000

143

429000

... More
Transportation of HDD machine with accessories including handling of stores materials preparation of site and boring (Boring size to accomodate two HDPE pipes of 40mm and 63mm outer dia) for placing and laying of S&T cables through HDPE pipe. Boring trench shall be minimum 3(three) meter below the river bed and minimum 1.5 (One point five) meter below surface in other patches. This item includes supply of HDPE pipes (of outer dia 40mm and 63mm) with RDSO/SPN/TC/45/2013 12 Rev. 2 or latest specification, minimum wall thickness 3mm with IP 67 protection with socket or coupler, having anti rodent properties and should be fire retardent to TEC specification. with accessories for HDPE pipe. Cost of fuel, jointing of pipes, if required and all other items which will be required for laying cable through HDPE pipe. This also includes laying of cables through boring. NOTE: 1. Work to be carried out as per instruction of site engineer. 2. HDPE pipe will be inspected by RITES (for value of materials equal or more than 5 Lakh Rupees) or Consignee (for value of materials less than 5 Lakh Rupees). Contractor shall submit Test Certificate from Original Manufacturer of HDPE pipes. 3. Payment will be made as per actual work done. Size: 110mm Boring upto the length of 150m

7000

887

6209000

... More
Installation of OFC Joint enclosure - includes splicing of Optic Fiber cable (24 fiber) along with testing, as per technical specification - jointing to be done in presence of railway representative; testing to be done jointly with division

20

2517

50340

... More
Provision of RCC pit - 1M below earth surface, with arrangement for entry and exit of HDPE pipe - as per Dwg No NF/TC/99-25 or latest - after laying of OFC, RCC pit shall be filled with sand and covered with suitable RCC covering slab

20

2738

54760

... More
Installation of thermoshrink jointing kit for 6 Quad cable - as per DOT/TEC specification (with RDSO modification for straight through joints) - as per technical specification - jointing to be done in presence of railway representative; testing to be done jointly with division

40

991

39640

... More
Provision of derivation joint - at approx every 1 Km (location as approved by Engineer- 16 in-charge) for emergency sockets and LC gates - using PIJF cable, thermo shrink jointing kit and 2T VF transformer - jointing to be done in presence of railway representative; testing to be done jointly with division

35

1481

51835

... More
Installation of straight through jointing kit - for PIJF cable - as per RDSO code of practice for PIJF jointing using thermo shrink joints - jointing to be done in presence of railway representative; testing to be done jointly with division

10

487

4870

... More
Fixing of 100/50/20 pair CT Box Krone type - includes termination of PIJF cable in ASM Room, Cable Hut, LC gate and other buildings - as per instructions of Engineer-in-charge and as per details in approved wiring / jointing schedule

50

395

19750

... More
Supply & Erection of Concrete Emergency post - as per Drg No SK/2004/00005 or 19 latest - includes transportation to site, digging of pit and erection of emergency post (complete with socket and socket box) - as per specification & drawing - includes wiring, testing and commissioning along side the Railway Track (at locations indicated by Engineer-in-charge) - does not include supply of emergency socket and emergency socket box

40

2004

80160

... More
Painting of telephone marking along with arrow mark - indicating the direction of 20 nearest emergency socket on hectometer posts installed alongside the railway track - enamel paint flourescent type (Asian / Berger or superior) should be used - dimensions to be got approved from Engineer-in-charge prior to commencement of work

350

17

5950

... More
Supply, transportation to site, erection & concreting the base of RCC Cable route 21 marker - for marking along the cable route / track crossing / road crossing for OFC and Quad cable - as per Dwg No NF/TC/99-23 or latest and as approved by Engineer-in-charge - painting on RCC route marker to be got approved from Engineer-in-charge prior to commencement of work

350

201

70350

... More
Testing of all the fibers of the optical fiber cable - before laying & after completion of laying and termination of cable in required location - includes all tests as detailed in technical specification - includes supply of all test reports, jointly signed with division

5

9222

46110

... More
Testing of all the Quads of the 6 Quad cable - before laying & after completion of laying and termination of cable in required location - includes all tests as detailed in technical specification - includes supply of all test reports, jointly signed with division

5

2861

14305

... More
Loading, transportation & unloading etc of cable drums, and other materials required for execution of work at site, from store to work site - as per instructions of Engineer-in-charge

70000

6

420000

... More
Fixing of GI Trunking on girder bridges including supply of channel angle iron bracket 27 unit,nuts and bolts of proper sizes and fitting of support at an intervel of one meter including laying of cable inside the troughs and filling with bitumen compound as per specification n. IRS:TC-25/76 after cable is laid, bitumen and other materials as required for the work shall be supplied by the contractor.

1000

404

404000

... More
Installation, Testing and Commissioning of station telephone (MASTER) of electronic LC 28 gate communication system as per RDSO specification No. RDSO/SPN/TC/51/2011(rev.3.0) with voice logging facility, surge protection & line connection unit and centralised power supply system with battery.

12

17133

205596

... More
Installation, Testing and Commissioning of 24 V DC power supply unit with MF battery for electronic LC gate telephone system as per RDSO specification No. RDSO/SPN/TC/51/2011 rev. 3.0

15

2492

37380

... More
Installation, Testing and Commissioning of Gate telephone ( Slave) with surge protection and line connection unit as per RDSO specification No. RDSO/SPN/TC/51/2011 rev.3.0

15

2398

35970

... More
Installation and commissioning of Add / Drop Mux, Primary digital drop insert multiplexer - with all accessories and power supply, surge & lightening protection arrangement, racks, 01 runway ladder etc. - in station / cable huts / test room - includes wiring of all the equipments upto Krone / CT Box / FDMS, including "U" links for derivation cables / OFC - includes fixing / installation of FDMS - as per station requirement - includes issue of OEM certificate, checklist (jointly signed with division) and training of duration as approved by Engineer-in-charge

7

19887

139209

... More
Supply and installation of MDF frame for accomodation of 100 pair Krone - includes all necessary wiring, all necessary wiring materials to be supplied by firm (if not included in schedule elsewhere)

12

8893

106716

... More
Supply and fixing of Quad cable termination box - includes termination of Quad cable 03 in ASM room on Wago / Disconnect terminals - or as per approval of Engineer-in-charge - includes supply of all necessary materials i.e. teakwood board (or superior quality wood as approved by Engineer-in-charge)

12

14500

174000

... More
Installation, testing and commissioning on OFC channels of control room equipment, 04 way side equipment, ADM and Control phone, FCT Phone - as per TS - includes wiring/termination, supply of all materials required (but not covered in schedule elsewhere) and restoration of surface / flooring / wall etc. to original condition

6

1450

8700

... More
Installation and commissioning of Quad cable link monitoring unit with battery - 06 includes supply of all wiring materials, teakwood (or superior quality wood, as approved by Engineer- in-charge) etc. required for execution of work, but not covered in schedule elsewhere - includes issue of OEM certificate, checklist (jointly signed with division) and impart of training of duration, as approved by Engineer-in-charge

10

8737

87370

... More
Installation of System Connectivity for BPAC working on OFC with 19" Rack mountable interface module as per TS

10

14109

141090

... More
Testing and final commissioning of all the equipments - in each station, conforming with the approved system design - includes end to end testing for realization of optical fiber system as per technical specification

6

59364

356184

... More
Digital Platform Clock- double side with GPS synchronization - as per RDSO Spec No RDSO/SPN/TC@47>47@2008 or latest

14

95935

1343090

... More
Digital Office Clock- single side with GPS synchronization - as per RDSO Spec No RDSO/SPN/TC@47>47@2008 or latest

6

19552

117312

... More
Supply of 3-core X 2.5 sq. mm multi strand power cable confirming the TS no.IS:694:1990 reaffirmed 1995 0r latest

2500

74

185000

... More
Online UPS - 2 KVA Capacity - for GPS Synchronised Clocks, as per TS. Make: APC/ Microtek/ Luminous

8

38454

307632

... More
Installation and commissioning of Digital Clocks - GPS Synchronized Platform and Office Clocks - by metal clamps at Platforms as per requirement and as advised by Engineer - in - Charge - as per TS 06

6

7961

47766

... More
Rack 19 inch 27U - Floor Mounted - Steel body - with 4 Nos trays, cooling fan complete with cables and power manager. Make: Rittal/ Valrack/ APW President 08

6

22913

137478

... More
Microphone with cord - Make: Ahuja, Model No. 99MS or similar 09

12

1165

13980

... More
PA Horn Speakers - 25 Watt - Make: Ahuja, Model No. UHC-25 with line matching transformer or similar 11

20

1534

30680

... More
Inverter - Pure Sine Wave Output - 800 VA Capacity - for PA system. Make: Luminous/ Microtek/ Amaron/ Exide

7

8144

57008

... More
VRLA Battery - 12V, 150 AH Capacity - suitable for Inverters. Make: Exide/ Amaron/ Okaya 14

7

15670

109690

... More
Supply & fixing of 1 inch conduit pipe (3m long) with all fitting materials 16

6000

72

432000

... More
Installation, testing & commissioning of complete Manual PA System with all accessories viz. Amplifiers,Racks,Microphones,Horn speakers,Power System, UPS and Battery etc. 18

6

1445

8670

... More
Counter communication system. Make: Ahuja or similar 19

12

9967

119604

... More
LAN extender 4 port - as per RDSO Spec. No RDSO/SPN/TC/82/2013. Make: CYGNUS/ DLINK/TEAM ENGINEERS

4

31366

125464

... More
Router 8 LAN, 08x2Mbps WAN V.35 with required cables and accessories, AC Power supply. Make: Cisco

2

293980

587960

... More
Router 4 LAN, 04x2Mbps WAN V.35 with required cables and accessories, AC Power supply. Make: CISCO

5

249475

1247375

... More
24 port Layer-2, 10/100 PROGRAMMABLE switch, with cables and accessories, AC power supply. Make: Cisco 24

7

34517

241619

... More
Modem G.703 - 2 Mbps. Make: MROTEK/ Cygnus/ Team Link 25

18

10541

189738

... More
Rack 19 inch 9-U - Steel Body - Wall Mounted - with cooling fans. Make: Rittal/ Valrack/ APW President 27

6

5311

31866

... More
CAT-6 cable - 24AWG 100Mhz. Make: DLINK 28

16

5532

88512

... More
RJ-45 Connector 29

200

7

1400

... More
RJ-45 LAN Cable 30

50

87

4350

... More
Wiring of CAT 6 cable through conduit pipe or casing caping 31

1000

6

6000

... More
Supply and Installation- Media Converter 10/100/ 1000 Mbps Single Mode Fiber. Make: DLINK/ TEAM ENGINNER/ MROTEK 33

4

11980

47920

... More
Installation of PRS /UTS Terminal Repeater Universal Model includes fixing of Terminal Repeater with clamping arrangement as per direction of site supervisor,all materials to be supplied by the contractor.

12

580

6960

... More
Installation of Routers, switch & modems etc. for PRS/UTSas per instruction of site supervisor.

6

9109

54654

... More
Supply and intallation of self supported Telescopic mast up to 15 meter Height as per TS including lightening spike at the top.

6

61175

367050

... More
A set of complete earthing system, maintenance free tripod type consisting of Copper rod as per RDSO/SPN/197/2016 or equivalent size strip, electrode with welded connecting rod and extension , copper cable for connection, Chemical earthing with ultra efficient Gel having earth impedance< 1ohm for filling around earth electrode.

12

50817

609804

... More
Installation,carrying out necessary digging work for fixing earth electrode in ground, Commissioning of complete earthing system,maintenance free tripod type consisting of copper rod/strip,extension,cable connections,filling around earth electrode chemical Earthing with ultra 03 efficient Gel having earth impedance< 1 ohm,all work of earthing as per standard practice and connecting it to equipments to be earthed, supply and providing copper earth lead wires multistrand lead wires, exothermic bonding with contractor,s materials all connections between earth electrodes and earthing, one end to earth electrode and the other end of the wire to block equipment, power equipment, cable sheath, signals etc. as per requirements & technical specification. 04

12

6359

76308

... More
Power supply 12V DC/20 Amps of reputed make . 05

7

6126

42882

... More
Battery (12V,120AH of reputed make like EXIDE or superior. 06

7

13492

94444

... More
25 W VHF Radio(Motorola/Kenwood ) make. 07

7

28559

199913

... More
Omni directional stacked Dipole Antena SWR less than 1.5 . 08

7

16277

113939

... More
Installation and commissioning of VHF system-complete with all accessories and power supply.

6

4672

28032

... More
Foundation for erection of self supported mast 15 meter high as per drg. Approved by Engineere in charge and as per TS

6

29530

177180

... More
Supply and Installation of polished wooden rack to accommodate 12V 120 AH battery and charger - of teakwood or superior quality wood, as approved by Engineer in charge of dimension.

6

7414

44484

... More
Supply of Standard 19" Rack Mountable LER ( Label Edge Router), IP-MPLS Router with Redundant DC power feed- 48 V DC nominal, equipped with interfaces: 2X10 G (Optical) SFP + ports along with 2 Nos. of 40 Kms 10 G SFP + LC Modules, 4X1 GbE (Opticasl) interface along with 4 Nos. of 01 1 GbE Single Mode Bi-directional SFP ( 10 KMs) Modules and 4X1 GbE ( Copper) based interfaces & Modules, 2X STM-1( Channelised) interfaces along with 2 Nos. of SFP ( S.1.1) Modules compatible with Existing STM-1,and slot for 16X E1 ( G. 703), {supply of 16 E 1 card is not included in this item } , Mounting kit with all necessary accessories & software, perpetual Licenses. Asd per RDSO Document No. STT/TAN/IP-MPLS/2020 Version 01 or latest. Inspection : RDSO

4

545560

2182240

... More
Supply of Standard 19" Rack Mountable Modular Chasis LSR ( Label Switch Router) IP- 02 MPLS Router with Redundant DC power feed- 48 V DC nominal,Redundant Controller Card, equipped with interfaces: 8X10 G (Optical) SFP + ports along with 8 Nos. of 40 Kms 10 G SFP + Modules, Mounting kit with all necessary accessories & software, perpetual Licenses. Asd per RDSO Document No. STT/TAN/IP-MPLS/2020 Version 01 or latest. Inspection : RDSO

2

1391314

2782628

... More
Installation,Commissioning & Testing of LER & LSR IP MPLS Routers including supply & 03 installation of all the accessories like power cable, Earthing cable, Optical Patch Cords of 3 mtr- 4 Nos. for LER & 8 Nos. for LSRs, CAT-6 patch cords of 1 mtr- 4 Nos, one 6 A MCB for each LER and LSR, wiring etc. as required for Routers.

6

73674

442044

... More
Supply and installation of 16 port E1 card along with patch panel /krone Module and wiring for Routers with all accessories etc. Inspection RDSO.

15

108289

1624335

... More
Supply, installation, testing and commissioning of Standard 19- inch Rack MountableLayer 3, 24 ports Managed Switch with 24 Nos. of 10/100/1000 Ethernet Ports with POE + Support and Redundant AC power Supply, Dedicated Stacking Module 4 X 10 GE SFP + Ports for uplink including 4 Nos. of 10 GE BX SM SFP + Modules, as per para Number 4.0 of RDSO Specification No. RDSO/SPN/TC/83/2020 Rev 2 or latest.Mounting kit with all necessary accessories to be supplied as per TS. Inspection RDSO

6

184477

1106862

... More
Supply of 2 X10 G Adapter interface without 10 G SFP + Modules for LER Routers. Inspection RDSO

2

60441

120882

... More
Supply of 8 X 1 G Adapter Interface ( any combination : one nos. of 8 X 1 G or two nos. of 4 X 1 G ) without SFP for LER Routers. Inspection RDSO.

2

63463

126926

... More
Supply of 2 X STM 1 Adapter Interface with 2 Nos. of STM-1, 20-25 Km, SFP modules for LER Routers, Inspection RDSO 09

2

247711

495422

... More
Supply of 10 G SFP+ Module with 40 Km range for above Routers.Inspection RDSO 10

2

132564

265128

... More
Supply of STM-1 SFP Module with 15 Km range with all accessories for above Routers. Inspection RDSO

2

9512

19024

... More
Supply of 10/100/1000 Base -T Copper Ethernet Transceiver SFP Module with all accessories. Inspection RDSO

2

6269

12538

... More
Supply of 12 Core Metal StrengthenedOutdoor Unarmoured Optic Fibre Cable(ITUTG- 652-D) and all the accessoriesrequired for installation, as per latestTEC/BSNL Specification as per TS. Inspection: RITES

500

11

5500

... More
Supply and Termination of 12 Fiber 12SC Type Rack Mountable FDMS loaded withSC '0' DB & Adaptor SC SM Pigtail1.5 meters with all the accessories required for installation as per TS. Inspection: RITES

6

7551

45306

... More
Supply of Single Mode Patch Cord length3 meters (LC-SC/SC-SC/LC-LC/FC-LC)as per site requirement, as per TS.Inspection: Consignee

25

604

15100

... More
Supply of STP CAT- 6 Cable compliantwith latest EIA/TIA-568-B-2-1 StandardforCAT 6 Cable 305 Meters Roll /Bundle. As Per TS, Inspection:RITES

610

27

16470

... More
Supply of PVC insulated 3 Core 6Sqmm,12 AWG 12.1 KV Grade Outdoor Strengthen Copper cable. As per TS.Inspection: Consignee.

700

165

115500

... More
Splicing /Dropping/Termination of each Fiber /Pigtail in the LIU/FDMS/Termination Joints through fusion Splicing of the termination of OFC Cables. As per Ts

200

37

7400

... More
Supply and installation of SIP Based Basic IP Phone with 128x64 Pixel Graphical LCD as per Specification.Inspection RITES

10

5294

52940

... More
Supply and Installation of Control IPTelephones with Hands Free and Gooseneck Operation for Way Side Station as Per Clause 11 of RDSO/SPN/TC/99/2012 Rev.2 or lates.AS per TS Inspection RDSO

10

18804

188040

... More
Wiring and Termination for IP Phones upto last point (includes configuring, fixing of I/O box, Drawing of UTP/OF Cable,Fixing of PVC Pipe /Casing capping. All miscellaneous materials required for fixing to be supplied by Contractor as per site requirement.

6

48130

288780

... More
Supply of Portable Maintenance Terminal (Similar to Laptop) as Per Clause No 8.7 and 8.9 RDSO/SPN/TC/99/2012 Rev.2 as per TS.

2

74220

148440

... More
Supply, Installation and Commissioning of Controller Console as Per Clause 9 of RDSO/SPN/TC/99/2012 Rev. 2 or latest.AS per TS. Inspection: RDSO

1

328669

328669

... More
Supply, Installation and Commissioning of Test Room Console as Per Clause 10 of RDSO/SPN/TC/99/2012 Rev. 2 or latest,AS per TS. Inspection: RDSO

1

441880

441880

... More
Supply, Installation and Commissioning of 4 Port Gateway to support 4 Port Concurrent 08 Emergency Communication at HQ/Way station to support 4 wire ports/ 4 Port Gateway with built in 2 wires to 4 wire Hybrid convertor to support 4 wire output as Per Clause 13 of RDSO/SPN/TC/99/2012 Rev.2 or latest. AS per TS. Inspection: RDSO

6

46668

280008

... More
Supply and installation of Station License of TCCS communication Server of 1+2 configuration as per RDSO/SPN/TC/99/2012 Rev.2. Inspection:RDSo

6

17222

103332

... More
Supply and installation of Port License of TCCS communication Server of 1+2 configuration as per RDSO/SPN/TC/99/2012 Rev.2. Inspection:RDSo

6

2222

13332

... More
Supply, Installation and Commissioning of Network Management Server as per Clause 5 and 8 RDSO/SPN/TC/99/2012 Rev.2 or latest as per TS.Inspection :RDSO

1

461384

461384

... More
Supply, Installation and Commissioning of Voice Recording Server as per Clause 5 and 7RDSO/SPN/TC/99/2012 Rev.2 or latest as per TS.Inspection :RDSO

1

704820

704820

... More
Supply, Installation and Commissioning of Event Notification Gateway as perClause12.3 of RDSO/SPN/TC/99/2012Rev.2 or latest, as per TS.Inspection: RDSO

1

250953

250953

... More
Supply, Installation and Commissioningof Desktop Client PC As per clause 8.7and 8.8 of RDSO/SPN/TC/99/2012 Rev.2 or latest along with 600VA UPS as per TS.

1

65630

65630

... More
Supply of 24 Port FXO Gateway 19" Rack mountable suitable for 96/48 FXS Gateway chassis along with patch panel/krone module. (AC or DC based) including mounting kit and all the accessories. As per TS. Inspection:Consignee

1

60902

60902

... More
Supply of DTMF Gateway 4 port as per clause 12 of RDSO/SPN/TC/99/2012 Rev 2 or latest.

1

78594

78594

... More
Supply, Installation And commissioning of Communication server as per clause 5 and 6 of RDSO/SPN/TC/99/2012 Rev.2 or latest. Total 2 servers, 1 at main location and one at remote location

2

1981180

3962360



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.