North Eastern Railway Tender

With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

North Eastern Railway - NER Tender

Works
Electrical and Electronics
Electrical Works
Ireps
Opening Date2 Dec 2024
Closing Date30 Dec 2024
Tender Amount₹ 34,27,147.8 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 2.5 04 sq.mm confirming to IS: 694 (Latest version) and drawing in laid( recessed /surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect. (Test report of NABL accredited laboratory should be submitted by firm at the time of supply of wire.)

2000

18

36000

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 6.0 sq.mm confirming to IS: 694 (Latest version) and drawing in laid (recessed /surface) PVC Conduit pipe 05 for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect. (Test report of NABL accredited laboratory should be submitted by firm at the time of supply of wire.)

2000

38

76700

... More
Digging of trench in all kinds of soil up to the depth of 750 mm and 350 mm wide for 06 laying of cable with supply and placing of second-class bricks, approx. 10 bricks per meter, refilling of cable trench with solid earth consolidating by ramming by 270 mm above the surrounding level over trench. (Digging of trench conforming to IS 1255).

1000

42

42520

... More
Laying of XLPE (LT) cable of different sizes in excavated cable trench and in underground pipes. (Laying of cable conforming to IS: 1255).

2000

4

9500

... More
Supply, Installation, Testing & commissioning of SPN MCB Distribution board 4 way 08 double door made with 1.2 mm thickness CRCA sheet fully powder coated of 50-70 micron with 01 No. MCB 02 pole 40 Amperes 10 KA 230 V as incoming and 02 Nos MCB of 6-25 Amp single pole 10 KA, 230 volts as outgoing complete in all respect including connection as required.

10

1028

10289

... More
Supply, making testing & commissioning of pipe earthing arrangement with GI pipe 'B' class, 40 mm dia 4.50 mtrs, long including accessories & providing masonry enclosure with cover 09 plate of 16 SWG M.S. having locking arrangement watering pipe , salt , charcoal etc. as per Drg. NO. DRM / Elect/IZN /16-89 to achieve earth resistance less than 10 ohms and connecting the equipment with 6 SWG G.I. wire as per site requirement. Earthing shall be done on the basis of code of practice for earthing as per IS: 3043/1987.

10

1344

13441.7

... More
All work pertaining to Horizontal Directional Drilling (HDD)/Boring and trench less cabling. It includes supply, transportation and insertion of self-lubricated HDPE pipe and laying of 10 cable in boring under the track/road by using different sizes of pipes depending on total number of cables will be crossed. The depth of horizontal boring should be 3 mtrs from rail flange/road level. This item will be used for track crossing of running lines.) By using self-lubricated HDPE pipe of 108.60 mm inner dia and 125 mm outer dia (PN-6) as per IS:4984 or latest in the bore and the laying of cables in the track/road.

600

1056

633930

... More
Fixing connecting testing and commissioning of LED streetlight fitting / LED High Bay 11 light on existing pole/ covered shed including with supply connecting testing of 1.5 sq.mm copper wire completes in all respect as per direction of engineer in charge at site. Note: -LED streetlight fitting and LED flood light fitting will be supplied by railway at site.

20

81

1629.8

... More
Supply, Fixing of distribution box in foundation, connecting testing and commissioning of LT distribution box made of 1.6 mm thick cold rolled steel sheet of size 600 mm (L) x 450 mm (W) x300 mm (D) with provision of water proof , hinged door, suitable locking arrangements, proper hole in the bottom for cable entry (incoming & out going cables) -05 Nos suitable and MS channel of size 75mm x 40mmx 4mm should be fixed across the panel for grouting on the foundation, earthing terminals and panel shall be powder coated (paint) greenish grey shade with TPN Copper Busbar of 12 600 Amps and supply fixing connecting testing and commissioning of 160 Amps MCCB 4 poles, braking capacity 25 KA complete with all respect with provision of water proofing and installation on Providing and making foundation to double door feeder pillar box (cubical type L.T. panel) in CC 1:2:4 with stare aggregate. [Size 1220 mm high x 800 mm length and 600 mm width (610 mm under the earth & 610 mm above the earth) with fine finish to exposed surface, two coats white washing including excavation of foundation, making proper size hole for incoming and outgoing cables. Grouting of holding down bolt in CC (size of bolt 150 mm long 16mm dia.) includes fixing of sub distribution box on CC foundation and as per direction of engineer in charge at site.

10

30108

301080

... More
Fixing, connecting, testing & commissioning of LED Tube light fitting 20 watt/ bulk 13 head fitting including making of hole in wall/ceiling by drilling machine for fixing tube light fitting with rowal plug 2 Nos & connecting with ceiling rose and connecting to electric supply wire complete in all respect. Note: -Fitting will be supplied by railway at site.

200

50

10000

... More
Supply of M.S. pipe 50 mm dia B class confirming to IS: 1239 (Part-1) (2004) for laying of cable through it as required complete in all respect. Make: -Jindal, TATA, swastik.

50

1924

96229

... More
Laying, threading & fixing of MS/GI pipe 50 mm dia including socket, fixing on CC flooring by suitable size of G.I clamps with bolts, fastener etc. as required.

50

180

9000

... More
Fabrication and erection of H pole structure including supply and fixing of M.S. angle 50 mm x50 mm x 6 mm for making bracing supporting insulators and M.S channel 100 mm x50 mm 16 of 7.9 Kg per meter with nut & bolts on tubular pole grouted by cement oncrete (1:3:6) including excavation of earth work and making of foundation of H pole with painting of H pole structure etc. as required. The H pole structure will be made as per drawing No.DRM/Elect/IZN/04/2005.

2

4900

9801.38

... More
Jointing, connecting & commissioning of heat shrinkable outdoor type end termination 17 kit for 11 KV X.L.P.E. (H.T.) Aluminum conductor cable 3 core 120 sq. mm. as direction of Engineer Incharge at site complete in all respect. Note: - Heat Shrinkable outdoor type termination Kits will be supplied by the railway at site.

6

2019

12118.08

... More
Cutting of platform/road for cable trench upto depth of 750 mm and 350 mm wide for aying of cable and making good the same including supply of extra quantities of material ie 18 aggregate, mooram, searching, red bajri, bitumen compaction, protection during work etc. and labour complete and laying of cable in excavated cable trench over 50 mm thick sand cushion and cover with second-class bricks (approx 10 bricks per Mtrs.) including supply of bricks, all taxes labour etc. as per direction of Engineer incharge at site. 19

100

105

10500

... More
Dismantling of existing rail/tubular with overhead mains pole complete in all respect.

12

672

8073

... More
Hiring & Installation of 15 KVA DG Set with fuel - 2 Nos, Hiring of DG Set 20 operator/electrician - 2 Nos and Hiring of 60 Nos LED streetlight 100 watt/ LED Flood light 100/150 watt on suitable size wooden/ Metallic pole as per site requirement as per direction of engineer Incharge at site.

3

12400

37200

... More
Supply and recessing/fixing of PVC Conduit pipe 25mm dia medium on surface confirming to IS: 9537/Part III/1983 (Latest version) including supply & fixing with all accessories i.e junction box, bend, clamping etc as per technical specifications complete in all respect.

600

34

20910

... More
Supply and Installation of Ceiling rose 3 plates as per IS:371/1999 (Latest version) including connections, testing and commissioning as per technical specification as per direction of Engineer in charge.

500

13

6845

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 1.5 03 sq.mm confirming to IS: 694 (Latest version) and drawing in laid( recessed /surface) PVC Conduit pipe for earth wire as required as per technical specification including connections, testing and commissioning complete in all respect. (Test report of NABL accredited laboratory should be submitted by firm at the time of supply of wire.)

600

11

7062

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 2.5 04 sq.mm confirming to IS: 694 (Latest version) and drawing in laid( recessed /surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect. (Test report of NABL accredited laboratory should be submitted by firm at the time of supply of wire.)

1200

18

21600

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 4.0 05 sq.mm confirming to IS: 694 (Latest version) and drawing in laid( recessed /surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect. (Test report of NABL accredited laboratory should be submitted by firm at the time of supply of wire.)

600

27

16668

... More
Digging of trench in all kinds of soil up to the depth of 750 mm and 350 mm wide for 06 laying of cable with supply and placing of second-class bricks, approx. 10 bricks per meter, refilling of cable trench with solid earth consolidating by ramming by 270 mm above the surrounding level over trench. (Digging of trench conforming to IS 1255).

1000

42

42520

... More
Laying of XLPE (LT) cable of different sizes in excavated cable trench and in underground pipes. (Laying of cable conforming to IS: 1255).

2000

4

9500

... More
Supply, Installation, Testing & commissioning of SPN MCB Distribution board 4 way 08 double door made with 1.2 mm thickness CRCA sheet fully powder coated of 50-70 micron with 01 No. MCB 02 pole 40 Amperes 10 KA 230 V as incoming and 02 Nos MCB of 6-25 Amp single pole 10 KA, 230 volts as outgoing complete in all respect including connection as required.

10

1028

10289

... More
Supply, making testing & commissioning of pipe earthing arrangement with GI pipe 'B' class, 40 mm dia 4.50 mtrs, long including accessories & providing masonry enclosure with cover 09 plate of 16 SWG M.S. having locking arrangement watering pipe , salt , charcoal etc. as per Drg. NO. DRM / Elect/IZN /16-89 to achieve earth resistance less than 10 ohms and connecting the equipment with 6 SWG G.I. wire as per site requirement. Earthing shall be done on the basis of code of practice for earthing as per IS: 3043/1987.

10

1344

13441.7

... More
All work pertaining to Horizontal Directional Drilling (HDD)/Boring and trench less cabling. It includes supply, transportation and insertion of self-lubricated HDPE pipe and laying of 10 cable in boring under the track/road by using different sizes of pipes depending on total number of cables will be crossed. The depth of horizontal boring should be 3 mtrs from rail flange/road level. This item will be used for track crossing of running lines.) By using self-lubricated HDPE pipe of 108.60 mm inner dia and 125 mm outer dia (PN-6) as per IS:4984 or latest in the bore and the laying of cables in the track/road.

100

1056

105655

... More
Fixing connecting testing and commissioning of LED streetlight fitting / LED High Bay 11 light on existing pole/ covered shed including with supply connecting testing of 1.5 sqmm copper wire complete in all respect as per direction of engineer incharge at site. Note: -LED streetlight fitting and LED flood light fitting will be supplied by railway at site.

150

81

12223.5

... More
Supply, Fixing of distribution box in foundation, connecting testing and commissioning of LT distribution box made of 1.6 mm thick cold rolled steel sheet of size 600 mm (L) x 450 mm (W) x300 mm (D) with provision of water proof , hinged door, suitable locking arrangements, proper hole in the bottom for cable entry (incoming & out going cables) -05 Nos suitable and MS channel of size 75mm x 40mmx 4mm should be fixed across the panel for grouting on the foundation, earthing 12 terminals and panel shall be powder coated (paint) greenish grey shade with TPN Copper Busbar of 600 Amps with provision of water proofing and installation on Providing and making foundation to double door feeder pillar box (cubical type L.T. panel) in CC 1:2:4 with stare aggregate. [Size 1220 mm high x 800 mm length and 600 mm width (610 mm under the earth & 610 mm above the earth) with fine finish to exposed surface, two coats white washing including excavation of foundation, making proper size hole for incoming and outgoing cables. Grouting of holding down bolt in CC (size of bolt 150 mm long 16mm dia.) includes fixing of sub distribution box on CC foundation and as per direction of engineer in charge at site.

4

11658

46632

... More
Fixing, connecting, testing & commissioning of LED Tube light fitting 20 watt/ bulk 13 head fitting including making of hole in wall/ceiling by drilling machine for fixing tube light fitting with rowal plug 2 Nos & connecting with ceiling rose and connecting to electric supply wire complete in all respect. Note: -Fitting will be supplied by railway at site.

500

50

25000

... More
Supply of M.S. pipe 50 mm dia B class confirming to IS: 1239 (Part-1) (2004) for laying of cable through it as required complete in all respect. Make:-Jindal, TATA, swastik.

100

350

35012

... More
Laying, threading & fixing of MS/GI pipe 50 mm dia including socket, fixing on CC flooring by suitable size of G.I clamps with bolts, fastener etc. as required.

100

180

18000

... More
Hiring & Installation of 15 KVA DG Set with fuel - 2 Nos, Hiring of DG Set 16 operator/electrician - 2 Nos and Hiring of 60 Nos LED streetlight 100 watt/ LED Flood light 100/150 watt on suitable size wooden/ Metallic pole as per site requirement as per direction of engineer Incharge at site.

6

12400

74400

... More
Supply and recessing/fixing of PVC Conduit pipe 25mm dia medium on surface confirming to IS: 9537/Part III/1983 (Latest version) including supply & fixing with all accessories i.e junction box, bend, clamping etc as per technical specifications complete in all respect.

300

34

10455

... More
Supply and Installation of Ceiling rose 3 plates as per IS:371/1999 (Latest version) including connections, testing and commissioning as per technical specification as per direction of Engineer in charge.

100

13

1369

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 1.5 03 sq.mm confirming to IS: 694 (Latest version) and drawing in laid( recessed /surface) PVC Conduit pipe for earth wire as required as per technical specification including connections, testing and commissioning complete in all respect. (Test report of NABL accredited laboratory should be submitted by firm at the time of supply of wire.)

300

11

3531

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 2.5 04 sq.mm confirming to IS: 694 (Latest version) and drawing in laid (recessed /surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect. (Test report of NABL accredited laboratory should be submitted by firm at the time of supply of wire.)

600

18

10800

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 4.0 05 sq.mm confirming to IS: 694 (Latest version) and drawing in laid( recessed /surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect. (Test report of NABL accredited laboratory should be submitted by firm at the time of supply of wire.)

400

27

11112

... More
Digging of trench in all kinds of soil up to the depth of 750 mm and 350 mm wide for 06 laying of cable with supply and placing of second-class bricks, approx. 10 bricks per meter, refilling of cable trench with solid earth consolidating by ramming by 270 mm above the surrounding level over trench. (Digging of trench conforming to IS 1255).

500

42

21260

... More
Laying of XLPE (LT) cable of different sizes in excavated cable trench and in underground pipes. (Laying of cable conforming to IS: 1255).

1000

4

4750

... More
Supply, Installation, Testing & commissioning of SPN MCB Distribution board 4 way 08 double door made with 1.2 mm thickness CRCA sheet fully powder coated of 50-70 micron with 01 No. MCB 02 pole 40 Amperes 10 KA 230 V as incoming and 02 Nos MCB of 6-25 Amp single pole 10 KA, 230 volts as outgoing Complete in all respect including connection as required.

4

1028

4115.6

... More
Supply, making testing & commissioning of pipe earthing arrangement with GI pipe 'B' class, 40 mm dia 4.50 mtrs, long including accessories & providing masonry enclosure with cover 09 plate of 16 SWG M.S. having locking arrangement watering pipe , salt , charcoal etc. as per Drg. NO. DRM / Elect/IZN /16-89 to achieve earth resistance less than 10 ohms and connecting the equipment with 6 SWG G.I. wire as per site requirement. Earthing shall be done on the basis of code of practice for earthing as per IS: 3043/1987.

4

1344

5376.68

... More
All work pertaining to Horizontal Directional Drilling (HDD)/Boring and trench less cabling. It includes supply, transportation and insertion of self-lubricated HDPE pipe and laying of 10 cable in boring under the track/road by using different sizes of pipes depending on total number of cables will be crossed. The depth of horizontal boring should be 3 mtrs from rail flange/road level. This item will be used for track crossing of running lines.) By using self-lubricated HDPE pipe of 108.60 mm inner dia and 125 mm outer dia (PN-6) as per IS:4984 or latest in the bore and the laying of cables in the track/road.

50

1056

52827.5

... More
Fixing connecting testing and commissioning of LED streetlight fitting / LED High Bay 11 light on existing pole/ covered shed including with supply connecting testing of 1.5 sqmm copper wire complete in all respect as per direction of engineer incharge at site. Note: -LED streetlight fitting and LED flood light fitting will be supplied by railway at site.

50

81

4074.5

... More
Supply, Fixing of distribution box in foundation, connecting testing and commissioning of LT distribution box made of 1.6 mm thick cold rolled steel sheet of size 600 mm (L) x 450 mm (W) x300 mm (D) with provision of water proof , hinged door, suitable locking arrangements, proper hole in the bottom for cable entry (incoming & out going cables) -05 Nos suitable and MS channel of size 75mm x 40mmx 4mm should be fixed across the panel for grouting on the foundation, earthing 12 terminals and panel shall be powder coated (paint) greenish grey shade with TPN Copper Busbar of 600 Amps with provision of water proofing and installation on Providing and making foundation to double door feeder pillar box (cubical type L.T. panel) in CC 1:2:4 with stare aggregate. [Size 1220 mm high x 800 mm length and 600 mm width (610 mm under the earth & 610 mm above the earth) with fine finish to exposed surface, two coats white washing including excavation of foundation, making proper size hole for incoming and outgoing cables. Grouting of holding down bolt in CC (size of bolt 150 mm long 16mm dia.) includes fixing of sub distribution box on CC foundation and as per direction of engineer in charge at site.

2

11658

23316

... More
Fixing, connecting, testing & commissioning of LED Tube light fitting 20 watt/ bulk head fitting including making of hole in wall/ceiling by drilling machine for fixing tube light fitting with rowal plug 2 Nos & connecting with ceiling rose and connecting to electric supply wire complete in all respect. Note: -Fitting will be supplied by railway at site.

400

50

20000

... More
Supply of M.S. pipe 50 mm dia B class confirming to IS: 1239 (Part-1) (2004) for laying of cable through it as required complete in all respect. Make: -Jindal, TATA, swastik.

100

350

35012

... More
Laying, threading & fixing of MS/GI pipe 50 mm dia including socket, fixing on CC flooring by suitable size of G.I clamps with bolts, fastener etc as required.

100

180

18000

... More
Hiring & Installation of 15 KVA DG Set with fuel - 2 Nos, Hiring of DG Set 16 operator/electrician - 2 Nos and Hiring of 60 Nos LED streetlight 100 watt/ LED Flood light 100/150 watt on suitable size wooden/ Metallic pole as per site requirement as per direction of engineer Incharge at site.

3

12400

37200

... More
Supply and recessing/fixing of PVC Conduit pipe 25mm dia medium confirming to IS: 9537/Part III/1983 (Latest version) with accessories, junction box etc including making chase, plastering/clamping etc as per technical specifications.

1000

36

36930

... More
Supply and recessing/fixing of PVC Conduit pipe 25mm dia medium on surface confirming to IS: 9537/Part III/1983 (Latest version) including supply & fixing with all accessories i.e junction box, bend, clamping etc as per technical specifications complete in all respect.

1000

34

34850

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 1.5 03 sq.mm confirming to IS: 694 (Latest version) and drawing in laid (recessed/surface) PVC Conduit pipe for earth wire as required as per technical specification including connections, testing and commissioning complete in all respect. (Test report of NABL accredited laboratory should be submitted by firm at the time of supply of wire.)

2000

11

23540

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 2.5 04 sq.mm confirming to IS: 694 (Latest version) and drawing in laid( recessed /surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect. (Test report of NABL accredited laboratory should be submitted by firm at the time of supply of wire.)

2000

18

36000

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 4.0 05 sq.mm confirming to IS: 694 (Latest version) and drawing in laid( recessed /surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect. (Test report of NABL accredited laboratory should be submitted by firm at the time of supply of wire.)

3000

27

83340

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 6.0 06 sq.mm confirming to IS: 694 (Latest version) and drawing in laid( recessed /surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect. (Test report of NABL accredited laboratory should be submitted by firm at the time of supply of wire.)

1000

38

38350

... More
Supply, Installation, testing & commissioning of Testing modular switch 10 Amps (1- way) complete in all respect as per direction of Engineer in charge.

150

58

8820

... More
Supply, Installation, testing & commissioning of modular type plug socket outlet 2/3 pin 10 Ampere complete in all respect as per direction of Engineer in charge.

30

97

2917.2

... More
Supply, Installation, testing & commissioning of modular type switch 20 Amps (1- way) complete in all respect as per direction of Engineer incharge.

30

119

3599.4

... More
Supply, Installation, testing & commissioning of modular type plug socket outlet 5/3 pin 20 Ampere complete in all respect as per direction of Engineer incharge.

-

-

10

... More
Supply and Installation of Ceiling rose 3 plate as per IS:371/1999 (Latest version) including connections, testing and commissioning as per technical specification as per direction of Engineer incharge.

80

13

1095.2

... More
Supply and recessing/fixing on surface of 6 SWG GI wire confirming to IS: 280/2006 (latest version) for earthing as required for earthing of installation as per IE Rule.

100

11

1142

... More
Installation, connection with twin core PVC insulated flexible copper conductor HRFR 13 cable of size 14/0.193 mm (0.41 sq.mm) testing and commissioning of 1200/1400 mm sweep AC ceiling fan/Air circulator (on the installed CI/MS Box) including earthing as per technical specification complete in all respect as per direction of engineer incharge. Note: - AC ceiling fan/Air circulator will be supplied by railway at site.

10

33

339.8

... More
Supply, Erection, testing & commissioning of Modular type step type Electronic Fan regulator complete in all respect.

10

188

1881.9

... More
Supply and Erection of modular type switch blanking set to fill the blank space white finished mounting cover plate complete in all respect.

10

7

71.3

... More
Supply and Erection of white finished mounting single mounting cover plate with base frame 8 modules suitable for mounting of modular type piano switches/plug socket, fan regulator and connecting to wiring complete in all respect.

15

132

1987.8

... More
Supply and Erection of Modular metal boxes concealed boards suitable for mounting 17 of 8 module white finish single mounting cover plate with frame and modular type piano switches/plug socket, fan regulators. Metal board boxes are to be concealed in wall complete in all respect.

15

72

1082.1

... More
Supply and Erection of white finished mounting single mounting cover plate with base frame 12 modules suitable for mounting of modular type piano switches/plug socket, fan regulator and connecting to wiring complete in all Respect.

15

191

2870.1

... More
Supply and Erection of Modular metal boxes concealed boards suitable for mounting 19 of 12 module white finish single mounting cover plate with frame and modular type piano switches/plug socket, fan regulators. Metal board boxes are to be concealed in wall complete in all respect.

15

116

1740.75

... More
Fixing, connecting, testing & commissioning of 600 mm wall air circulator fan complete in all respect as per direction of Engineer In-charge.

20

218

4362.4

... More
Digging of trench in all kinds of soil up to the depth of 750 mm and 350 mm wide for 21 laying of cable with supply and placing of second-class bricks, approx. 10 bricks per meter, refilling of cable trench with solid earth consolidating by ramming by 270 mm above the surrounding level over trench. (Digging of trench conforming to IS 1255).

400

42

17008

... More
Laying of XLPE (LT) cable of different sizes in excavated cable trench and in underground pipes. (Laying of cable conforming to IS: 1255).

800

4

3800

... More
Supply, Fixing, connecting, testing & commissioning of 380 mm sweep, 1400 rpm (approx.), propeller type Exhaust fan complete in all respect as per direction of engineer in charge.

10

2867

28674

... More
Supply, erection and testing of hot dip galvanized tapered octagonal pole of 5.0 Mtrs. Long top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimension (L x B x T) 200 mm x 200 mm x 12 mm & foundation bolts size (No. x dia x length) (4 x M16 x 600 mm), PCD 200 mm, anchor plate thickness 3 mm with hot dip galvanized detachable single arm bracket made by 48.3 mm outer dia pipe 300 mm long with 32 mm outer dia sleeve including erection & fixing on the foundation. (Octagonal pole shall confirm to IS: 2629 or latest.) Note:-1. Galvanized thickness of pole should be minimum 65 microns and test report to be submitted by the contractor at the time of supply. 2. Octagonal pole shall have flush door arrangement and suitable size & length of cable connecting plate for incoming and outgoing cables as per standard. Note:-Octagonal pole shall be inspected by the RITES as per specification at the manufacture premises and inspection cost shall be borne by the contractor.

-

-

24

... More
Making trench of size 300 mm x 300 mm x 1000 mm and casting/grouting of pre-cast foundation CC 1:2:4 block size 300 mm x 300 mm x 1000 mm grouting with 20 mm size stone aggregate with cement & coarse sand including supply, fixing and removing all firm work and 25 finishing exposed surface including grouting and holding down-M 16x 450 mm- 4 Nos bolts in cement block as per requirement of pole base plate of size 200x200x12 mm and supply & fixing Double Walled Corrugated (DWC DPDE Duct Pipe, size 90/76 mm, confirming to IS:14930 (Part-II) 0.75 meter length in the center of cement concrete block for cable entry and fixing properly with all labour, material, cement etc. complete in all respect as per direction of engineer in-charge at site.

5

1910

9552.05

... More
Fixing connecting testing and commissioning of LED streetlight fitting 90 watt and 26 LED Flood light on pole/ covered shed including supply and connection with twin core PVC insulated flexible copper conductor cable of size 1.5 sq.mm complete in all respect as per direction of engineer incharge at site. Note: -LED street light fitting will be supplied by railway at site.

5

81

407.45

... More
Supply of LED flood light 400 watt, LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest, Types of LED Modules as per the IS: 16103 (Part-2)/2012, The entire housing (both LED section and driver section) shall be dust and water proof having IP 66 protection as per IS:10322 (Part 1):1982 latest, Colour temperature 6000K (+/-500K), Working life for LED (Minimum 50,000 burning hours as per LM-80 report), Complete LED 27 flood light shall be of Bajaj, Philips, Jaguar or equivalent make complete in all respect. Note: - LED flood light shall be inspected by the RITES as per specification at the manufacture premises and inspection cost shall be borne by the contractor. (Successful Tenderer shall submit WARRANTEE GUARANTEE (WG) @ 10% of the Contract Value of this item in the prescribed proforma before claiming the payment for this item.) Note: - LED flood light fixture 400 Watt complete shall be guaranteed/warranted for a period of 60 months from the date of commissioning for satisfactory performance.

35

21476

751660

... More
Fixing, connecting, testing and commissioning of LED flood light fitting 400 watts, on covered shed/suitable places as per direction of Engineer in charge at site. Note: - LED flood light fitting will be supplied by railway at site.

35

97

3395

... More
Fixing, connecting, testing & commissioning of LED Tube light fitting 20 watt/ LED 29 down lighter including making of hole in wall/ceiling by drilling machine for fixing tube light fitting with rowal plug 2 Nos & connecting with ceiling rose and connecting to electric supply wire complete in all respect. Note: -Fitting will be supplied by railway at site.

100

50

5000

... More
SITC of VTPN distribution board 4 way as per IEC 61439-3, suitable for flush mounting and surface mounting, 100 Amps copper bus bar for each phase with two neutral bar, two earth bar and cable ties for cable management, fully insulated bus bar & shrouded Neutral bars, Improved Pan assembly for ease of installation, refitted masking sheet, with provision for TPN MCB as incomer and 30 SP MCB's outgoing, IP 43 with metal door with fixing & connecting. Along with 01 No.- MCCB's 4 pole 100 Amps, Breaking capacity 25 KA, rated voltage 415V 50 Hz AC supply conforming to IS: 13947 (Pt.1&2)/IEC60947-1&2- 03 No.- MCB 'C' curve, no. of poles -two pole, rated voltage 415 V AC, rated current Amps:63 Amps, rated short circuit current capacity 10 KA rated frequency : 50 Hz, AC conforming to IS:60898-1/2002. 10 No.- Single pole MCB 16 Amps, 'C' curve, 10 KA, ISI marked conforming to IS/IEC 60898-1-2002.

4

23616

94464.76

... More
Supply, Installation, Testing & commissioning of SPN MCB Distribution board 4-way 31 double door made with 1.2 mm thickness CRCA sheet fully powder coated of 50-70 micron with 01 No. MCB 02 pole 40 Amperes 10 KA 230 V as incoming and 02 Nos MCB of 6-25 Amp single pole 10 KA, 230 volts as outgoing complete in all respect including connection as required.

10

1028

10289

... More
Supply, making testing & commissioning of chemical earthing arrangement to achieveearth resistance less than 2.5 ohms and connecting the equipment complete as per site requirement. Earthing shall be done on the basis of code of practice for earthing as per IS: 3043/1987.

10

2850

28500

... More
Design, supply & making of double door feeder pillar box made of 2.0 mm thick cold rolled steel sheet of size 600 mm (L) x 450 mm (W) x 300 mm (D) with provision of water proof, hinged door, suitable locking arrangements, proper hole in the bottom for cable entry (incoming & out going cables 05 No), suitable of MS channel of size 75 mm x 40 mm x 4.8 mm should be fixed across the panel for grouting on the foundation, earthing terminals and panel shall be powder coated (paint) greenish grey shade with TPN copper bus bar 400 Amps - 01 Set, including Supply, fixing, 33 connecting, testing & commissioning of MCCB-100 Amps 04 pole - 01 No & MCB SP&N 32 Amps - 02 Nos in the feeder pillar box. Providing and making foundation for double door feeder pillar box (cubical type LT panel) in CC 1:2:4 with stone aggregate of [Size 1220 mm high x 800 mm length and 600 mm width (610 mm under the earth & 610 mm above the earth)] with fine finish to exposed surface, two coats white washing including excavation of foundation, making proper size hole for incoming and outgoing cables. Grouting of holding down bolt in CC (size of bolt 150 mm long 16 mm dia) included fixing of sub distribution box on CC foundation as per direction of Engineer in charge at site.

4

13832

55328



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.