National Cooperative Consumers Federation Of India Limited Tender

With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

National Cooperative Consumers Federation Of India Limited - NCCF Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date16 Mar 2024
Closing Date5 Apr 2024
Tender Amount₹ 20,85,04,570 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and displaying of Areca Palm having ht. 1.20 m to 1.50 m with 5 to 6 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.

40

6766

169.15

... More
Providing and Displaying Budded Rose (H.T. variety) 3 to 4 healthy branch 30 cm and above ht. well developed with one and above flower plant in 20 cm Earthen Pot, as per direction of the officer-in-charge.

20

656

32.8

... More
Providing and Displaying Cycus revoluta specimen , having 45 to 50 fresh and healthy, leaves having 30cm to 35cm circumfrance of base stem well developed in 40 cm challi, as per direction of the officer-in-charge.

10

15375

1537.5

... More
Providing and Displaying Fishtail palm well developed with fresh & healthy foliage leaves of ht 210 to 240cm Specimen in 35 cm Cement Pot as per direction of the officer-in-charge.

20

6150

307.5

... More
Providing and Displaying Foxtail palm well developed with fresh & healthy foliage of ht. 210 to 240 cm in big 40 cm Cement Pot as per direction of the officer-in-charge.

20

23678

1183.9

... More
CARRIAGE OF MATERIALS

-

-

-

... More
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.

25

12352

494.1

... More
EARTH WORK

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.

2549.72

663692

260.3

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consol'dat'ng each depos'ted layer by ramm'ng, waterng, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :

-

-

-

... More
All kind of soil

-

-

-

... More
Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia.

250

88037

352.15

... More
Pipes, cables etc. exceeding 300 mm metre dia but not exceeding 600 mm

250

137437

549.75

... More
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.

20446.68

14322899

700.5

... More
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

8100

72495

8.95

... More
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material

-

-

-

... More
Beyond 30 cm girth upto and including 60 cm girth

1

532

532.35

... More
Beyond 60 cm girth upto and including 120 cm girth

1

2373

2373.5

... More
Beyond 120 cm girth upto and including 240 cm girth

1

11020

11020.15

... More
Supplying chemical emulsion in sealed containers including delivery as specified

707.56

166099

234.75

... More
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.:

-

-

-

... More
With Chlorpyriphos/ Lindane E.G. 20% with 1% concentration

92.25

4930

53.45

... More
Treatment of soil under existing floors using chemical emulsion@ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement: 2 Coarse sand) to match the existing floor:

-

-

-

... More
With Chlorpyriphos/Lindane E.G. 20% with 1% concentration

800

248040

310.05

... More
CONCRETE WORK

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

257.28

1752591

6812

... More
Centering and shuttering including strutting, propping etc. and removal of form work for :

-

-

-

... More
Foundations, footings, bases for columns

1237.02

485097

392.15

... More
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-Ill) derived from natural sources: 4 graded stone aggregate 12.5 mm nominal size derived from natural sources

236.37

97112

410.85

... More
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.

53.61

973

18.15

... More
REINFORCED CEMENT CONCRETE

-

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

74.92

677707

9045.75

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

18

195353

10852.95

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas,lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).

201.32

2316287

11505.5

... More
Centering and shuttering including strutting, propping etc. and removal of form work for :

-

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete

2376.22

931834

392.15

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc

3365.01

2835020

842.5

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform

944.58

875861

927.25

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

1590

1170876

736.4

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

1097.34

1054872

961.3

... More
Stairs, (excluding landings) except spiral-staircases

54.9

41995

764.95

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.

-

-

-

... More
Thermo-Mechanically Treated bars of grade Fe-500D or more.

228748

24670471

107.85

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level

-

-

-

... More
Thermo-Mechanically Treated bars of grade more. Fe-500D or

85085.65

9176487

107.85

... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

-

-

-

... More
All works upto plinth leveL

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum

1834.09

17432566

9504.75

... More
All works above plinth level upto floor V level

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum

744.2

7338109

9860.4

... More
MASONRY WORK

-

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)

651.35

6086442

9344.35

... More
Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement: 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

301.65

3075457

10195.45

... More
CLADDING WORK

-

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red

110

595485

5413.5

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

256.2

324848

1267.95

... More
WOOD AND P.V.C. WORK

-

-

-

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood

2.19

255179

116520.3

... More
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.

-

-

-

... More
35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws

80

277908

3473.85

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).

198

91545

462.35

... More
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : Kiln seasoned and chemically treated hollock wood 50x12 mm

100

18595

185.95

... More
50x20 mm

100

21320

213.2

... More
Providing and fixing nickel plated M.S.pipe curtain rods with nickel plated brackets:

-

-

-

... More
25 mm dia (heavy type)

60

11184

-

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.

-

-

-

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding

175

38342

219.1

... More
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.

40

44994

1124.85

... More
Providing & Fixing decorative high pressure laminated sheet of plain I wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.

-

-

-

... More
1mmthick

175

157027

897.3

... More
Providing and fixing factory made Fiberglass Reinforced plastics (F.R.P.) chajja 4 mm thick of required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology, resulting in void free compact laminate in single piece, having smooth gradual slope curvature for easy drainage of water and duly reinforced by 2 nos vertically and 1 nos horizontally 50x2 mm thick M.S. flat with 12 mm in built hole for grouting on the existing wall along with the 50 mm flanges duly inserted and sealed in the wall complete in one single piece casted monolithically, including all necessary fittings . The FRP Chajja should be manufactured using unsaturated Polyester resin as per IS: 6746, duly reinforced with fibre glass chopped strand mat (CSM) as per IS: 11551 complete with protective Gel coat U/V coating on Top for complete resistance from the extreme of temperature, weather & sunlight (Only plan area of chajjas shall be measured for making payment).

22.33

116282

5207.45

... More
Providing and fixing, in position concealed G.I. section for wall paneling using board of required thickness fixed on the 'W' profile (0.55 mm thick) having a knurled web of 51.55 mm and two flanges of 26 mm each with lips of 10.55 mm, placed @ 610 mm C/C in perimeter channel having one flange of 20 mm and another flange of 30 mm with thickness of 0.55 mm and web of length 27 mm. Perimeter channel is fixed on the floor and the ceiling with the nylon sleeves @ 610 mm C/C with fully threaded self-tapping dry wall screws. Board is fixed to the 'W' profile with 25 mm countersunk ribbed head screws @ 200 mm C/C., all complete as per the drawing & directions of engineer-in-charge, the joints of the boards are finished with specially formulated jointing compound and 48mm wide jointing tape to provide seamless finish. Multipurpose cement board reinforced with suitable fibre cement screw. 8 mm thick Cement bonded wood particle board as per IS:14276

175

249865

1427.8

... More
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet (Zinc coating not less than 120 gm/sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/sqm. The frame will have a provision of G.I. anchor fastners 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of size 100x89x3 mm for fixing of fire rated glazed shutter. The frame shall be finished with an approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- Charge. (Cost of SS ball bearing hinges is excluded).

13

28637

-

... More
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes Fire rating conforming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/ sqm) duly filled mineral wool insulation having density minimum 96 kg/ cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3 mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately).

6.77

81361

-

... More
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-Charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (El20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & El. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredited labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.

4

174710

43677.65

... More
STEEL WORK

-

-

-

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

1275

160331

125.75

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

30920.16

4134025

133.7

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S.laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.

-

-

-

... More
80x1.25 mm M.S. laths with 1.25 mm thick top cover

56.73

207246

-

... More
Providing and fixing ball bearing for rolling shutters.

6

2954

492.35

... More
Extra for providing mechanical device chain and crank operation for operating rolling shutters.

-

-

-

... More
Exceeding 10.00 sqm and upto 16.80 sqm in the area

56.73

72690

1281.35

... More
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).

10

7682

768.25

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes

500

103175

206.35

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.

-

-

-

... More
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

1500

258900

172.6

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

675

521370

772.4

... More
FLOORING

-

-

-

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand) :

-

-

-

... More
25 mm thick

128.47

250291

1948.25

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (Double charge/Mat finish/Glossy Vitrified tiles)

-

-

-

... More
Size of Tile 600x600 mm

1628

2529016

1553.45

... More
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.

-

-

-

... More
Size of Tile 600x600 mm

1628

503133

309.05

... More
ROOFING

-

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansio n,(i) Single socketed pipes. 75 mm diameter

160

39808

248.8

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter

280

105672

377.4

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 75 mm

48

4401

91.7

... More
110 mm

60

8169

136.15

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Single Push Fit Coupler

-

-

-

... More
110 mm dia

20

2552

127.6

... More
Single tee with door

-

-

-

... More
110x110x110 mm

30

7020

234

... More
Bend 87.5 deg

-

-

-

... More
75 mm bend

16

1694

105.9

... More
110 mm bend

20

3007

150.35

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete

-

-

-

... More
110 mm dia

230

85399

371.3

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :

100

174415

1744.15

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross 'T' of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.

-

-

-

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross 'T' of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.

1628

3606264

2215.15

... More
Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.56mm Aluminium color profile with center to center pitch of 175 mm, depth of 46mm, top crest width of 41mm, bottom valley width of 80mm, overall profile width of 1144mm, cover width 1050mm.

18.3

27157

1484

... More
FINISHING

-

-

-

... More
12 mm cement plaster of mix : 1:6 (1 cement : 6 coarse sand)

3299

1133701

343.65

... More
15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand)

3451.5

1364550

395.35

... More
Neat cement punning.

789.07

63086

79.95

... More
Extra for providing and mixing water proofing material in cement per bag of plaster work in proportion recommended by the manufacturers.

470.93

10407

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete

3451.5

538606

156.05

... More
Colour washing such as green, blue or buff to give an even shade : New work (two or more coats) with a base coat of white washing with lime

50

2665

53.3

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre

5047.72

937109

185.65

... More
Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm)

1521.73

177890

116.9

... More
Finishing walls with textured exterior paint of required shade :

-

-

-

... More
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

1931.5

431883

-

... More
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.

-

-

-

... More
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.

1308.14

237100

181.25

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :

-

-

-

... More
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

211.04

47747

226.25

... More
French spirit polishing :

-

-

-

... More
Two or more coats on new works including a coat of wood filler

25

11156

446.25

... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats

3453.23

493121

142.8

... More
ROAD WORK

-

-

-

... More
Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom.

-

-

-

... More
With medium setting bitumen emulsion

-

-

-

... More
On W.B.M / W.M.M. @ 0.4kg/sqm

2855.44

60535

21.2

... More
On bituminous surface @ 0.25kg/sqm

2855.44

40118

14.05

... More
Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size (Passing 11.2 mm sieve and retained on 2.36 mm sieve) per 100 sqm of road surface, including rolling and finishing with power road roller all complete. Note: Seal coat items to be operated only with the prior approval of chief Engineer concerned.

2855.44

373634

130.85

... More
Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete. New work (Two or more coats)

22.44

6482

288.9

... More
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)

608

228486

375.8

... More
Providing and laying bituminous macadam using crushed stone aggregates of specified grading premixed with bituminous binder, transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge.

-

-

-

... More
50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 3.50% (percentage by weight of total mix) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity

285.54

2428703

8505.65

... More
Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge.

-

-

-

... More
40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.

177.15

2148156

-

... More
Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bilingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge.

-

-

-

... More
Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm

3

21550

7183.35

... More
Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm

3

16679

5559.75

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

25

252940

-

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.

-

-

-

... More
Made of G.I. wire of dia 4 mm

75

76335

1017.8

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.

-

-

-

... More
With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25

656.75

1920895

2924.85

... More
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

125

252200

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

725

791337

1091.5

... More
WATER SUPPLY

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall

-

-

-

... More
15 mm nominal bore

110

31548

286.8

... More
20 mm nominal bore

120

40200

335

... More
25 mm nominal bore

250

100387

401.55

... More
32 mm nominal bore

65

33718

518.75

... More
40 mm nominal bore

150

105442

702.95

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc

-

-

-

... More
For Internal Toilet (Domestic, Flushing )

-

-

-

... More
15 mm nominal outer dia Pipes

40

19912

497.8

... More
20 mm nominal outer dia Pipes

40

21504

537.6

... More
25 mm nominal outer dia Pipes

80

50180

627.25

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work

-

-

-

... More
15 mm nominal bore

20

4894

244.7

... More
20 mm nominal bore

20

5486

274.3

... More
25 mm nominal bore

35

12439

355.4

... More
50 mm nominal bore

92

73071

794.25

... More
CConstructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design

-

-

-

... More
With common burnt clay F.P.S (non modular) bricks of class designation 7.5

40

79704

1992.6

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
With common burnt clay non-modular bricks of class designation 7.5

55

597432

10862.4

... More
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :

-

-

-

... More
With common burnt clay non-modular bricks of class designation 7.5

25

472417

18896.7

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank

7500

82500

11

... More
DRAINAGE

-

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1: 2 (1 cement: 2 fine sand) including testing of joints etc. complete:

-

-

-

... More
150 mm. dia. RCC Pipes

450

250402

556.45

... More
250 mm. dia. RCC Pipes

250

224950

899.8

... More
300 mm. dia. RCC Pipes

15

14914

994.3

... More
900 mm. dia. RCC Pipes

6

28505

4750.85

... More
2. WATER SUPPLY AND DRAINAGE

-

-

-

... More
Providing & Fixing C.I double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete ( the tail pieces, tapers etc if required will be paid separately)

-

-

-

... More
50mm dia

5

28744

5748.8

... More
80mm dia

2

13987

6993.6

... More
PILE WORK

-

-

-

... More
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia piles

6576

20159385

3065.6

... More
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.

-

-

-

... More
Single pile upto 50 tonne Safe capacity

-

-

-

... More
Initial test (Test Load 2.5 times the Safe capacity)

4

219086

54771.5

... More
Routine test (Test Load 1.5 times the Safe capacity) 2 piles of 100. Pile will be choosen randomly by Engineer-in-charge.

17

333750

19632.4

... More
ALUMINIUM WORK

-

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :

-

-

-

... More
For fixed portion

-

-

-

... More
Powder coated aluminium (minimum thickness of powder coating 50 micron)

1427.67

757950

530.9

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)

-

-

-

... More
Powder coated aluminium (minimum thickness of powder coating 50 micron)

561.8

356434

634.45

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge.

-

-

-

... More
Pre-laminated particle board with decorative lamination on both sides

80

89232

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):

-

-

-

... More
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)

80

120420

1505.25

... More
WATER PROOFING

-

-

-

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement ompound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and ealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

85

52449

617.05

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :

-

-

-

... More
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

800

1347680

1684.6

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

-

-

-

... More
For vertical surface two coats @ 0.70 kg per sqm

393.95

186298

472.9

... More
RAIN WATER HARVESTING

-

-

-

... More
RECHARGE PITS 4 Nos

-

-

-

... More
Earth work in exacavation in trenches for foundations and for pipes cables etc. in ordinary soil(loam clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in a lead of 50m.

-

-

-

... More
In all kind of soil upto 1.5m depth

630

346342

549.75

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :

-

-

-

... More
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

12

140245

11687.1

... More
Boringldrilling bore well of required dia for casing/ strainer pipe, by suitable method rescribed in S: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.

-

-

-

... More
Drilling of 300mm dia bore hole manually.

60

42465

707.75

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in- charge.

-

-

-

... More
200 mm nominal size dia

68

75707

1113.35

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

4

6039

1509.8

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

4

6153

1538.25

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.

4

6153

1538.25

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

4

8098

2024.5

... More
BORING OF TUBEWELL (1 no's)

-

-

-

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-lll) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

325.7

244047

749.3

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore iog, 'ncIud'ng h're a‹ runn'ng charges of all equ'pments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, up to 90 metre depth below ground level.

-

-

-

... More
All Types of Soil

-

-

-

... More
300mm dia

90

63697

707.75

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.

-

-

-

... More
All Types of Soil

-

-

-

... More
300mm dia

60

49542

825.7

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with Mo coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge

-

-

-

... More
150 mm nominal size dia having minimum wall thickness 5.00 mm

35

27763

793.25

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge

-

-

-

... More
150 mm nominal size dia

35

28260

807.45

... More
Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

1

1509

1509.8

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

1

1538

1538.25

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in- charge.

1

1538

1538.25

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading fl sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

1

2024

2024.5

... More
Development of tube well in accordance with IS: 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in- charge.

1

1085

1085.05

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:

-

-

-

... More
100 mm dia

1

224

224.1

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.

-

-

-

... More
100 mm clamp.

1

1911

1911.4

... More
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).

-

-

-

... More
100 mm dia

1

265

265.1

... More
CIVIL NDSR ITEM

-

-

-

... More
Supplying & Fixing of 4 mm thick ACP

50

56700

1134

... More
Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:

-

-

-

... More
With 20x2Omm square bar

40

18760

469

... More
Supply & Installation of 12mm thickness Laminated Wooden Flooring along with underlaying 2mm thick foam for shock absorption

17.91

76583

4276

... More
Providing and fabrication of turbo vent 600 mm dia. On roof including all fixtures and base and water tight sealent complete including transportation, unloading and handling at site. Turbo vent

20

370000

18500

... More
Fire Door Fittings

-

-

-

... More
Supply & Fitting of Fire Rated SS BB Hinges 4" x 3" x 3mm

12

4389

365.75

... More
Supply & fitting of Door Closer

4

11704

2926

... More
Supply & Fitting of Double Leaf panic bar make

4

52136

13034

... More
Supply & fitting of panic Trim

4

23940

5985

... More
Supply & fitting of Anchor Fastener, 10x100mm

24

2074

86.45

... More
Supplying and fixing min. 18 mm thick smooth finish black granite inauguration stone of superior quality with overall size of 1500X900mm with ornamental edge moulded granite / marble / cement plaster band of approved shape. The prepared block shall be fixed with cement mortar 1:3 (1 Cement: 3 Coarse sand) in brick wall/block work with tiles/stone after chased, including finishing and painting all-round the stone and making aesthetically beautiful. The inauguration stone should contain engraved letters with chemically printing /stainless steel of approved matter in Hindi & English of required colour and size etc. and provision of curtain raising/sliding, light and landscaping/area development all around, complete as approved by CLIENT

2

36250

18125

... More
Supplying and fixing min.18 mm thick smooth finish black granite inauguration stone of superior quality with overall size of 1000X750mm or 2000X1000, with ornamental edge moulded granite / marble / cement plaster band of approved shape. The prepared block shall be fixed with cement mortar 1:3 (1 Cement: 3 Coarse sand) in brick wall/block work with tiles/stone after chased, including finishing and painting all-round the stone and making aesthetically beautiful. The inauguration stone should contain engraved letters with chemically printing /stainless steel of approved matter in Hindi & English of required colour andsize etc. and provision of curtain raising/sliding, light and landscaping/area development all around, complete as approved by CLIENT

1

18500

18500

... More
Providing & fixing in position Frame less sensor operated glass double shutter sliding doors with 12 mm thick toughened glass with approved etching design manufactured to relevant I.S. codes from approved manufacturer including cost of activators, switches, track and mounting profile, Carrier, Door suspension device with adjustable fixture, Motor with decoder, Track rail, Return pulley, Basic module, control with integrated switched power supply unit and multi-way connectors for optional expansion modules, Door stop etc.Dorma/KICH/OZONE Make or Equivalent as required all complete at all heights and as directed by the Engineer-in-Charge.

2

786000

393000

... More
Providing and installation plastic garbage bins(FRP/HDPE) of min 120l capacity of approved model of approved make, design & spec as per standard/norms complpete with all fitting, fixtures, lids, wheels etc.

10

40000

4000

... More
HARDWARE FITTINGS

-

-

-

... More
Providing and fixing of ISI marked Stainless steel grade 304 Sliding door bolts with nuts & screws etc. complete as per approved makes. Size: 300 x 16 mm./250X16mm

84

41580

495

... More
Providing and fixing of ISI marked Stainless steel grade 304 Tower bolt with nuts & screws etc. complete as per approved makes. Size: 250 x 10 mm.

64

17472

273

... More
Size: 150 x 10 mm.

20

6500

325

... More
Providing and fixing of ISI marked Stainless steel grade 304 Handle with nuts & screws etc. complete as per approved makes. Lock Body Make Godrej or equivalent.

20

41000

2050

... More
Providing and fixing of ISI marked Stainless steel grade 304 door stopper with nuts & screws etc. complete as per approved makes. Siz, Make Godrej or equivalent.

42

10500

250

... More
Providing and fixing of ISI marked Narrow Stile 6 lever Mortice lock , Make Godrej or equivalent.

10

9070

907

... More
Providing and fixing of Mortice lock set with handle size 65mm, Make Harrison or equivalent.

32

47296

1478

... More
SANITARY INSTALLATIONS

-

-

-

... More
Providing and fixing vitreous chinaware white extended Wall Hung with European water closet all complete with C.P. bolts & nuts with C.P. hinges, rubber buffers etc. complete in all respects of Size 545 x 350 xx 360 mm, Make Cera, Jaquar, Hindware or Perryware

15

368355

24557

... More
Providing & fixing of health faucet of ABS body with 1 meter SS braided connection pipe, Make Cera, Jaquar, Hindware or Perryware

15

33450

2230

... More
Providing and fixing white vitreous china flat back urinal with integrated EFS along with necessary fittings and making good the walls and floors wherever required. Make Cera, Jaquar, Hindware or Perryware

8

211576

26447

... More
Providing & Fixing of table top vitreous china Wash Basin of Size 605 x 395 x 120 mm, Make Cera, Jaquar, Hindware or Perryware

12

173736

14478

... More
Providing and fixing of 5 mm thick bevelled edge float glass frameless mirror of size 700 x 500 mm fixed with stainless steel studs, all complete.

6

17784

2964

... More
Providing and fixing of 5 mm thick bevelled edge float glass frameless mirror of required size fixed with stainless steel studs, all complete.

14

27160

1940

... More
Providing and fixing toilet paper holder.

15

32775

2185

... More
Providing & Fixing of S.S. Bib Cock with wall flange and aerator, Make Cera, Jaquar, Hindware or Perryware

15

54600

3640

... More
Providing and fixing C.P. brass concealed stop cock Make Cera, Jaquar, Hindware or Perryware

20

31300

1565

... More
Providing and fixing CP Brass Waste Coupling (half thread) for wash basin and sink, Make Cera, Jaquar, Hindware or Perryware

12

9000

750

... More
Providing and fixing 32mm dia Flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.

55

15675

285

... More
Providing & Fixing NRV Valve 50mm

8

47560

5945

... More
Providing & Fixing Gate Valve 40mm

6

25872

4312

... More
SS Grab Bars with anti slip grips

-

-

-

... More
Providing and Fixing Wall mounted Foldable/drop down grab bar/safety rail min 600mm long, make Cera or equivalent.

15

73140

4876

... More
Providing and fixing SS 304 Grade sinks (without drainboard) made of stainless steel 1mm thick of size 600 x 445 mm, make Cera or equivalent.

5

45425

9085

... More
Supply ,installation , testing ,commissioning of VERTICAL MULTISTAGE PUMP along with associated motors, control panel, cables, accessories, electrics,instruments,junction box, other associated items/equipments required for complete operation of pump set including valves,fittings,instruments on suction and delivery line. Product Configuration Pump Classification: Hydro-Pneumatic Booster System Pump Construction: Pump With Motor Parallel Pumping System Numbers of Pump in a Set: 3 Pump (2W+1S) Component Materials Version: Cast Iron & S.S AISI 304 Seal Material: Cartridge-Carbon/SiC/SS316/FKM Bearing Material: Ceramic/Tungsten Carbide Rubber Parts: NBR (Nitrile) Motor Specifications Mounting: IEC Enclosure: TEFC Phase: 3 Voltage: 380-415V Efficiency Class: IE2 Motor System Components Accessories: Including Header Flange Rating: PN 16 Pump Controller: Pump Sequencer Pump Controller Including Pressure Tank of required capacity.

-

-

-

... More
Flow Rate of each pump = 50 LPM, 2HP

2

91756

45878

... More
SUB HEAD : IV - DRAINAGE

-

-

-

... More
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 including cutting, jointing, wastage, but excluding cost of Njointing

-

-

-

... More
Single Socket Type B for (Internal Toilet and external wall)

-

-

-

... More
110mm SWR UPVC pipe lines laid complete

150

63894

425.96

... More
75mm SWR UPVC pipe lines laid complete

150

43485

289.9

... More
Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc.

-

-

-

... More
For Wash basin

-

-

-

... More
32mm dia pipe

15

2918

194.56

... More
32mm Bend(45°)

11

561

51

... More
32mm Bend(90°)

11

484

44

... More
For Urinal

-

-

-

... More
50mm

16

6848

428

... More
50mm Bend(45°)

7

623

89

... More
50mm Bend(90°)

7

784

112

... More
Providing & Installation of SS jali 100mm

55

4400

80

... More
Providing, fixing, jointing and testing , of PVC Nahani Trap without jali of minimum 50 mm water seal, making necessary cutting in slab or floors and making good including supports with cement concrete 1:3:6 complete as approved by Engineer-in-Charge.

-

-

-

... More
110mm x 75mm (Toilet)

15

19215

1281

... More
110mm x 75mm (Drinking water & water cooler)

3

3843

1281

... More
110mm x 75mm (Kitchen)

3

3843

1281

... More
Portable RO system (20Litre capacity) Chiller cum water dispenser with inbuilt R.O. Purifier

7

523250

74750

... More
Providing and Installation of Towel Rail, 600 mm long

18

65772

3654

... More
Providing and Installation of Gyser (Usha) Capacity - 15Litre

2

32474

16237

... More
Supply and Installation of submersible pump set with 100 LPM discharge , 10HP and sufficient Head complete with column pipes & fittings. The pumps shall be vertical, submersible, multistage centrifugal, stainless steel (304) casing, stainless (304) impeller, stainless steel (316) shaft, ceramic bearings, tungsten carbide shaft protection bushes and mechanical seal driven suitable rated motor with 1500/2900 RPM, 415z10% Volts, 50 Cycles, AC 3 — phase Each pump shall be capable of operating within a performance pressure characteristic range sufficient below and above the required working press ure. The Pump shall conform to Indian standard IS: 8034. Pumps and motors shall be mounts on a common MS structural base plate. The pump shall be water cooled coupled to induction motor of suitable H.P and R.P.M specified in schedule of quantities. Pumping set shall be provides with a Gun Metal "Bourden" type pressure gauge with gunmetal isolation cock and connecting piping. The pump set shall be provided with gun metal gate valve of appropriate sizes on delivery & non-return valve of appropriate size and a pressure gauge with cock shall be provided on the delivery line. These shall be as per detailed design distribution and requirement at different Zones at the location of bore wells to be finalized during detailed engineering subject to the confirmation by local statutory authorities by the Contractor at his own cost. Contractor shall obtain all approvals / permissions from concerned authorities at his own cost, 10HP.

1

105000

105000

... More
Providing and fixing 80 mm thick insulated puff panels on roof of approved colour conforming to relevant IS code includoing overlapping, jointing, riveting, bolting, clamping etc. all complete as per instructions of Engineer's in charge and manufactures specification. The panels having density not less than 40Kg/m3 (+2/-2), U value 0.53 W/m2, tensile strength 3.7Kg/sqm and bending strngth 4kg/sqm.

1034.56

3036433

2935

... More
Providing and fixing 40 mm thick insulated interlocking puff panels on wall cladding of approved colour conforming to relevant IS code includoing camlocking, jointing, riveting, bolting, clamping etc. all complete as per instructions of Engineer's in charge and manufactures specification. The panels having density not less than 40Kg/m3 (+2/-2), U value 0.28 W/m2, tensile strength 3.7Kg/sqm and bending strngth 4kg/sqm.

497.11

1215433

2445

... More
Providing and fixing of S.S. letters with ACP Sheet at back.

936

650520

695

... More
Providing and fixing of Roller Blinds

75

103500

1380

... More
Furniture (Supply & Installation)

-

-

-

... More
Providing and Installation of Executive Desk including tranportation, unloading with fittings complete as per direction of engineer incharge. Make methodex or equivalent.

2

112877

56438.8

... More
Providing and Installation of Officer Desk including tranportation, unloading with fittings complete as per direction of engineer incharge. Make methodex or equivalent.

27

864000

32000

... More
Providing and Installation of Executive Chair including tranportation, unloading with fittings complete as per direction of engineer incharge. Make methodex or equivalent.

2

56000

28000

... More
Providing and Installation of Officer Chair including tranportation, unloading with fittings complete as per direction of engineer incharge. Make methodex or equivalent.

20

447700

22385

... More
Providing and Installation of Visiter Chair including tranportation, unloading with fittings complete as per direction of engineer incharge. Make methodex or equivalent.

76

952280

12530

... More
Providing and Installation of Sofa Set including tranportation, unloading with fittings complete as per direction of engineer incharge. Make methodex or equivalent.

1

82925

82925.04

... More
Providing and Installation of 3 Seater Waiting Bench including tranportation, unloading with fittings complete as per direction of engineer incharge. Make methodex or equivalent.

20

441900

22095

... More
Providing and Installation of Conference Desk of size 3600 x 2100 x 750, including tranportation, unloading with fittings complete as per direction of engineer incharge. Make methodex or equivalent.

1

125200

125200

... More
Providing and Installation of Rectangular shape 4 seater plastic dining table including tranportation, unloading with fittings complete as per direction of engineer incharge.

10

85000

8500

... More
Providing and Installation of Plastic Armless Chair including tranportation, unloading with fittings complete as per direction of engineer incharge

45

126237

2805.28

... More
Providing and Installation of Centre table including tranportation, unloading with fittings complete as per direction of engineer incharge. Make durian or equivalent.

2

52000

26000

... More
WIRING

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated oopper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.

-

-

-

... More
Group A

250

330750

1323

... More
Group C

150

294300

1962

... More
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.

60

126360

2106

... More
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.

1200

552000

460

... More
Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.

150

105600

704

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required

-

-

-

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

2000

784000

392

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

1200

546000

455

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire

500

313000

626

... More
2 X 10 sq. mm + 1 X 10 sq. mm earth wire

500

377500

755

... More
2 X 16 sq. mm + 1 X 16 sq. mm earth wire

150

150300

1002

... More
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire

100

59500

595

... More
4 X 4 sq. mm + 2 X 4 sq. mm earth wire

100

72000

720

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire

125

122750

982

... More
4 X 10 sq. mm + 2 X 10 sq. mm earth wire

75

93000

1240

... More
4 X 16 sq. mm + 2 X 16 sq. mm earth wire

50

87450

1749

... More
Supplying and drawing following sizes of FRLS PVC insulated, Copper Conductor Single Core Cable in Surface/ Recessed medium class PVC conduit as required.

-

-

-

... More
1 x 1.5 sq. mm

150

7200

48

... More
Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
2 Pair

900

36000

40

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

300

15000

50

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
25 mm

3000

462000

154

... More
32 mm

800

156800

196

... More
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.

-

-

-

... More
200 mm X 150 mm X 75 mm deep

75

28950

386

... More
250 mm X 300 mm X 60 mm deep

30

19350

645

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
3 pin 5/6 amp socket outlet

300

39000

130

... More
6 pin 15/16 amp socket outlet

100

20900

209

... More
Telephone socket outlet

30

4710

157

... More
TV antenna socket outlet

5

785

157

... More
Bell push

10

1490

149

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

125

49000

392

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

200

8600

43

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.

-

-

-

... More
1 or 2 Module (75mmX75mm)

60

19020

317

... More
3 Module (100mmX75mm)

40

13920

348

... More
4 Module (125mmX75mm)

50

18250

365

... More
6 Module (200mmX75mm)

100

42700

427

... More
8 Module (125 mmX125mm)

50

24150

483

... More
12 Module (200mmX150mm)

50

29100

582

... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.

-

-

-

... More
1 or 2 Module

60

8460

141

... More
3 Module

40

6440

161

... More
4 Module

50

8400

168

... More
6 Module

100

19400

194

... More
8 Module

50

11200

224

... More
12 Module

50

14450

289

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

20

2100

105

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

125

45000

360

... More
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

100

4900

49

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.

-

-

-

... More
Upto 450 mm sweep

10

4780

478

... More
Supplying & installing UTP networking Cat-6 cable suitable for LAN/WANcom puter net working as per catalog no. DC6CAUTP4P3X.

600

36108

60.18

... More
Supply and Erecting modular type computer jack RJ 45 ISI mark approved make with mounting plate and box with wiring connections complete.

20

9581

479.08

... More
Supplying and fixing suitable size GI raceway ( (min 100mm wide and 38mm deep, 1.6mm thick) with partition & junction box, cover etc ( separate for Electrical & IT wiring-50mm each) of reputed makes (Legrand/OBO/Anchor) to be laid from the nearest power/LAN point on the wall.

100

54000

540

... More
Supply & installation of 12 watts LED ceiling luminaires, suitable for ceiling/surface mounting, complete in all respects with accessories.

30

43470

1449

... More
Supply & installation of decorative type, recess mounted, 15W watts LED ceiling luminaires, suitable for recess mounting, complete in all respects with accessories.

40

112896

2822.4

... More
Supply & installation of 22 Watt LED Batten and other accessories, suitable for surface / pendant mounting - wall/ceiling mounting complete in all respects & as specified in the technical specification.

10

5250

525

... More
Supply & installation of , (IP20) with 40 watts induatrial LED Batten and other accessories, suitable for surface / pendant mounting - wall/ceiling mounting complete in all respects & as specified in the technical specification.

90

370800

4120

... More
Supply & installation of corrosion resistant, decorative type, Recess mounted, Mirror Optics fixtures (IP52) with 34/36 watts LED fixture and other accessories, complete in all respects . Make: Havells or equivalent

150

932400

6216

... More
Supply & installation of Area Flood Lighting Fixtures suitable for 100W LED (IP66), weather proof Marshalling box having 4 brass strips for connection of incoming and outgoing cables with glands, suitable for loop in loop out arrangement, 1 No. 16 Amps Fuse / fuse base with 2 Amps re-wireable type fuse, 660v grade, 3 x 1.5 mm2, PVC insulated flexible copper wire for connection of fixture, making connections, earthing etc. complete as required & as specified in the technical specification. Make: Havells or equivalent

8

97440

12180

... More
Supply & installation of Area Flood Lighting Fixtures suitable for 120W LED (IP66), weather proof Marshalling box having 4 brass strips for connection of incoming and outgoing cables with glands, suitable for loop in loop out arrangement, 1 No. 16 Amps Fuse / fuse base with 2 Amps re-wireable type fuse, 660v grade, 3 x 1.5 mm2, PVC insulated flexible copper wire for connection of fixture, making connections, earthing etc. complete as required & as specified in the technical specification. Make: Havells or equivalent

5

66700

13340

... More
Supply and installation of heavy duty Wall mounted fans, 750mm sweep, Air Delivery 370 m.cu/min, maximum 250watts, not less than 1440 rpm, 90 degree rotation, single phase 230V AC, inherent regulator & DOL Starter etc. complete in all respect as specified in the technical specification. Make: Havells or equivalent

6

128973

21495.6

... More
Supply and installation of heavy duty Wall mounted fans, 450 mm sweep, maximum 55 watts, not less than 1300 rpm, 90 degree rotation, single phase 230V AC, inherent regulator etc. complete in all respect as specified in the technical specification. Make: Havells or equivalent

20

258174

12908.7

... More
Supply of AC 230/250 volts, 50 HZ ceiling fan with standard down rod, blades, 2 nos. caps & regulator etc. ISI marked complete as required. Make: Havells or equivalent

-

-

-

... More
1200 mm sweep

125

496875

3975

... More
Supply of electric exhaust fan of sweep 300 mm, 240 Volts, minimum 900 rpm, maximum 60 Watts, totally enclosed split phase start, induction run, rated for continuous duty, with GI louvers shutter etc. completely wired, along with nut bolt and washer for fixing in wall, plastering & making good disturbed surfaces etc. complete in all respect, as per IS 2312: 1967 as specified in the technical specification. Make: Havells or equivalent

5

29452

5890.5

... More
Supply of PVC Body Brisk Air exhaust fan of sweep 250 mm, 240 Volts, minimum 950 rpm, maximum 50 Watts, totally enclosed split phase start, induction run, rated for continuous duty, with louvers shutter etc. completely wired, along with nut bolt and washer for fixing in Aluminium window complete in all respect, as per IS 2312: 1967 as specified in the technical specification. Make: Havells or equivalent

5

12694

2538.9

... More
MCCB, MCB & DB'S

-

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
6 way, Double door

8

18768

2346

... More
8 way, Double door

4

10944

2736

... More
12 way, Double door

2

4924

2462

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
4 way (4 + 12), Double door

2

8700

4350

... More
6 way (4 + 18), Double door

8

42312

5289

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single Pole

120

32640

272

... More
Single pole and neutral

40

25480

637

... More
Double pole

30

20940

698

... More
Triple pole and neutral

20

26120

1306

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

100

1400

14

... More
Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
40 amps

5

5155

1031

... More
63 amps

20

21980

1099

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
40 amps

10

28090

2809

... More
63 amps

2

5788

2894

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
40 amps

4

13560

3390

... More
63 amps

10

30540

3054

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 25 Amp. Modular Motor starter for AC complete with all connections, testing etc. as required.

30

26850

895

... More
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

2

8734

4367

... More
Providing and fixing HT danger notice plate 250 mm x 200 mm made of mild steel at least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red colour on front side as required.

5

1550

310

... More
CABLE TRAYS

-

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

300

192600

642

... More
300 mm width X 50 mm depth X 1.6 mm thickness

300

247800

826

... More
EARTHING

-

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

35

255115

7289

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

31780

7945

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

200

10800

54

... More
Supplying and laying 50 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

150

22950

153

... More
Providing and fixing 50 mm X 6 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

150

247350

1649

... More
Providing and fixing 4.00 mm dia copper wire on surfaoe or in recess for loop earthing as required.

200

33000

165

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

200

9000

45

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

50

21750

435

... More
Providing and fixing earth bus of 25 mm x 5 mm copper strip on surface for connections etc. as required.

15

33705

2247

... More
LIGHTNING CONDUCTOR

-

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

2

1102

551

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

150

19950

133

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

150

31350

209

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

5

645

129

... More
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

200

41400

207

... More
MV CABLE LAYING

-

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundincluding excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Upto 35 sq. mm

50

20550

411

... More
Above 35 sq. mm and upto 95 sq. mm

100

43100

431

... More
Above 95 sq. mm and upto 185 sq. mm

50

22450

449

... More
Above 185 sq. mm and upto 400 sq. mm

50

25200

504

... More
Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Upto 35 sq. mm

50

14300

286

... More
Above 35 sq. mm and upto 95 sq. mm

100

30400

304

... More
Above 95 sq. mm and upto 185 sq. mm

50

16150

323

... More
Above 185 sq. mm and upto 400 sq. mm

50

18950

379

... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
Upto 35 sq. mm

50

1950

39

... More
Above 35 sq. mm and upto 95 sq. mm

50

3050

61

... More
Above 95 sq. mm and upto 185 sq. mm

50

4100

82

... More
Above 185 sq. mm and upto 400 sq. mm

50

7100

142

... More
MV CABLE JOINTING & END TERMINATION

-

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
3½ X 70 sq. mm (38mm)

10

4980

498

... More
3½ X 95 sq. mm (45mm)

10

6250

625

... More
HV CABLE JOINTING & END TERMINATION

-

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required

-

-

-

... More
240 sq. mm

4

69112

17278

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :

-

-

-

... More
240 sq. mm

2

48476

24238

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :

-

-

-

... More
240 sq. mm

2

89088

44544

... More
MVCABLE

-

-

-

... More
Supplying of following sizes of 1.1 kV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required

-

-

-

... More
4C x 10 Sq.mm Al. XLPE arm.

250

33300

133.2

... More
4C x 16 Sq.mm Al. XLPE arm.

500

75000

150

... More
3.5 C x 25 Sq.mm Al. XLPE arm.

350

61740

176.4

... More
3.5 C x 35 Sq.mm Al. XLPE arm.

150

33840

225.6

... More
3.5 C x 50 Sq.mm Al. XLPE arm.

100

29160

291.6

... More
3.5 C x 70 Sq.mm Al. XLPE arm.

100

39600

396

... More
3.5 C x 95 Sq.mm Al. XLPE arm.

200

95760

478.8

... More
3.5 C x 120 Sq.mm Al. XLPE arm.

650

389220

598.8

... More
3.5 C x 150 Sq.mm Al. XLPE arm.

100

70920

709.2

... More
3.5 C x 185 Sq.mm Al. XLPE arm.

250

221100

884.4

... More
3.5 C x 240 Sq.mm Al. XLPE arm.

300

333720

1112.4

... More
SINGLE CORE COPPER UNARMOURED CABLE POWER/ EARTHING:

-

-

-

... More
Supply and laying of 1.1kV grade PVC insulated, unsheathed, stranded copper conductor unarmoured cable (IS:694) in PVC pipes/ on existing cable trays/raceways etc. including terminations:

-

-

-

... More
1C x 2.5sq.mm PVC insulated copper conductor wire for furniture/boxes earthing.

1500

30600

20.4

... More
1 C x 25 sq.mm PVC insulated copper conductor unarmoured cable.

15

4068

271.2

... More
HV CABLE

-

-

-

... More
Supply of following 11 kV (LIE) grade multicore Aluminium conductor XLPE insulated cable, insulation screening with extruded semi conducting compound in combination with copper tape armoured cores laid up, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - II) and complete with all latest amendments etc. complete as required.

-

-

-

... More
3 C x 70 Sq. mm 33 kV (UE)

50

150000

3000

... More
H V CABLE LAYING

-

-

-

... More
Laying of one number XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Above 120 sq. mm and upto 400 sq. mm

40

25200

630

... More
EXTERNAL WORKS

-

-

-

... More
BREAKER SINGLE PANEL (AT GATE)

-

-

-

... More
Supplying, installation, connecting, testing & Commissioning of outdoor type (IP-56) Single panel with incoming & outgoing busbar, 11kV, 3 Phase, 3 Wire, 50 Hz, effectively earthed, 26.3 kA fault current (500MVA Fault level), Vacuum Circuit Breaker, earthing trolley as per IS: 13118, all steel totally enclosed, Metal clad, Horizontal drawout, floor mounting, main Burbar & Earth Busbar shall be EC Grade Copper. The details are following.

-

-

-

... More
1-INCOMER/1-0UTGOING

1

665000

665000

... More
1 No.-lncoming each equipped with the following:

-

-

-

... More
Vacuum Circuit Breaker-800Amp Three Phase

-

-

-

... More
Current Transfomer­

-

-

-

... More
Ratio: 50/1+1A

-

-

-

... More
Core-1 CL: 1.0, 15VA for metering & Core-2 CL:5P20, 15VA for protection

-

-

-

... More
Potential Transformer-

-

-

-

... More
Ratio: 11kV/11OV

-

-

-

... More
CL:1/100VA

-

-

-

... More
Digital Ammeter With selector switch, Digital Voltmeter with selector switch

-

-

-

... More
Relays-

-

-

-

... More
Numerical ralay with following minimum protections:

-

-

-

... More
IDMT + INST 0/C (50P+51P)

-

-

-

... More
Nutral 0/C (50N,51N)

-

-

-

... More
Ground Fault 0/C (50G,51G)

-

-

-

... More
Directional Sensitive 0/C (67N)

-

-

-

... More
Sensitive & Restricted E/F (50SEF, REF)

-

-

-

... More
Thermal Overload (49F)

-

-

-

... More
Phase undervoltage (27) with timer

-

-

-

... More
Phase discontinuty (46PD)

-

-

-

... More
Circuit breaker failure (50BF)

-

-

-

... More
Auto reclose (79)

-

-

-

... More
Fuse failure protection of line PT (97)

-

-

-

... More
Auxiliary VAA relays as reqquired

-

-

-

... More
DC fail relay

-

-

-

... More
Trip circuit supervision relay

-

-

-

... More
Antipumping relay

-

-

-

... More
PT Transfer Scheme

-

-

-

... More
METERS-

-

-

-

... More
Digital Ammeter With selector switch

-

-

-

... More
Digital Voltmeter With selector switch

-

-

-

... More
Multifunction meter (A, V, F, PF, kW, kWH, kVA, kVAR, MD)

-

-

-

... More
Set of indication Lamp-

-

-

-

... More
Red-Breaker "ON"

-

-

-

... More
Green-Breaker "OFF"

-

-

-

... More
Amber-Breaker "Auto Trip"

-

-

-

... More
White-Trip Circuit Healthy

-

-

-

... More
Blue-DC Supply fail

-

-

-

... More
Amber-Spring fully charged

-

-

-

... More
Amber-Test position

-

-

-

... More
Green-Sevice position

-

-

-

... More
Red - Isolated position

-

-

-

... More
Set of fine wiring, Ferrules & Fuses Power-Pack 110/24V DC Supply for simltaneous tripping of three breakers.

-

-

-

... More
OUTGOING-

-

-

-

... More
Terminals to connect the HT Cable

-

-

-

... More
Main LT. Panel

-

-

-

... More
Suppy, installation, testing, Design, manufacture, supply inspection, handling, assembling, affecting proper connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type Main LT. Panel with PLC based Synchronisation, load manager, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623. The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable or Aluminium Bus Duct as required.

1

1275000

1275000

... More
All incoming & outgoing MCCB's shall be microprocessor based with 0/L & SIC and E/F protection beyond 250A.

-

-

-

... More
All MCCB's shall be lcs = 100% lcu, with rotary handle & pad locking arrangement, with adjustable 0/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link.

-

-

-

... More
The breaking capacity specified for all MCCB's breakers is lcs value (service rating).

-

-

-

... More
The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, cast resin type CT's & PT's, etc. Separate CT's shall be provided for protective and measuring system and for APFCR of capacitor bank with suitable VA.

-

-

-

... More
All Energy Analyser I TVM Shall have RS 485 Modbus RTU on board Communication protocol for SCADA communication.

-

-

-

... More
The fault withstanding capacity of panel & its control gear shall be min. 65/50 kA rms for 1 sec.

-

-

-

... More
GA drawings shall be got approved from Owners / Architects / Consultants before fabrication.The panel has to be specifically fabricated as per the space available at site. The existing column positions will also be considered.

-

-

-

... More
INCOMERS from 1 Nos. 160 kVA Transformers

-

-

-

... More
The incoming MCCB shall be micropocessor based with inbuilt O/L & S/C release with E/F protection and all Outgoings MCCB's up to 250 amp shall be thermal- magnetic based with inbuilt O/L & S/C release and MCCB's more than 250 amp to 800 amp shall have microprocessor baed with in built O/L, S/C AND E/F Protection

-

-

-

... More
All MCCB's shall have rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with solid isolable neutral link. The breaking capacity specified is lcs value. All outgoing MCB's shall be C type with 10 kA breaking capacity.

-

-

-

... More
All incoming MCCB's shall be electrically interlocked with the bus coupler, DG incomers and other transformer incomers.

-

-

-

... More
All Incomers shall be of 4P, EDO with EN 6400 multifunction meters

-

-

-

... More
All Outgoings shall be of 4P MDO type only but with ON and OFF indication lamps

-

-

-

... More
TRANSFORMER INCOMERS: 400 AMP FP EDO MCCB - 1 SETS

-

-

-

... More
All incoming MCCB shall be electrically interlocked with the bus coupler, DG incomers and other transformer incomers.

-

-

-

... More
Over Voltage/ Under Voltage relay I release with timer.

-

-

-

... More
Backup earth fault relay.

-

-

-

... More
Master trip relay.

-

-

-

... More
Trip Circuit Supervison relay.

-

-

-

... More
1 nos. 0-500 volt range digital type & 1 no analog voltmeter with selector switch

-

-

-

... More
1 set of 3 CT's of ratio 400/5A, Class 1.0 accuracy 15 VA burden for metering.

-

-

-

... More
1 set of 3 CT's of ratio 400/5A, Class 1.0 accuracy 15 VA burden for APFCR.

-

-

-

... More
1 set of 3 CT's of ratio 400/5A, Class 5P20, accuracy 15 VA burden for PROTECTION .

-

-

-

... More
1 no. 0-2000 Amp range digital type ammeter with selector switch.

-

-

-

... More
Energy analyser (digital type) consisting of I, V, kW, kWH, kVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation.

-

-

-

... More
Power factor meter.

-

-

-

... More
Frequency meter.

-

-

-

... More
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxillary relay, 2 sets of push buttons.

-

-

-

... More
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFFITRIP/ Trip circuit healthy/ DC supply healthy. Each lamp shall be with bakup MCB.

-

-

-

... More
DG INCOMERS: 250 AMP FP EDO MCCB -2 Nos

-

-

-

... More
All incoming MCCB shall be electrically interlocked with the bus coupler, DG incomers and other transformer incomers.

-

-

-

... More
Over Voltage / Under Voltage relay / release with timer.

-

-

-

... More
Backup earth fault relay.

-

-

-

... More
Master trip relay.

-

-

-

... More
Trip Circuit Supervison relay.

-

-

-

... More
1 nos. 0-500 volt range digital type voltmeter with selector switch

-

-

-

... More
1 set of 3 CT's of ratio 500/5A, Class 1.0 accuracy 15 VA burden for metering.

-

-

-

... More
1 set of 3 CT's of ratio 500/5A, Class 5P20, accuracy 15 VA burden for PROTECTION .

-

-

-

... More
1 no. 0-1250 Amp range digital type ammeter with selector switch.

-

-

-

... More
Energy analyser (digital type) consisting of I, V, kW, kWH, kVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication I report generation.

-

-

-

... More
Power factor meter.

-

-

-

... More
Frequency meter.

-

-

-

... More
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxiliary relay, 2 sets of push buttons.

-

-

-

... More
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFFITRIP/ Trip circuit healthy/ DC supply healthy. Each lamp shall be with bakup MCB.

-

-

-

... More
Control transformer of 2.5 kva shall be provided in all bus section with control bus.

-

-

-

... More
Protection releases/ relays, Metering & Accessories for Bus Couer (s)

-

-

-

... More
Trip circuit supervision relay

-

-

-

... More
TNC switch.

-

-

-

... More
Auto I manual selector switch

-

-

-

... More
5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF/ TRIP/Trip circuit healthy/ DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB.

-

-

-

... More
The bus coupler shall be electrically interlocked with all incoming MCCB's in such a way that at any one time two supply should not get mixed up.

-

-

-

... More
BUS BARS

-

-

-

... More
40 AMP, 415 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC/ DMC supports, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints. The current density of bus bar shall be minimum 1.00 sq mm / amp.

-

-

-

... More
The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C.

-

-

-

... More
PLC for Synchronisation, load management/ automation

-

-

-

... More
Design, manufacturing, testing at works, supply of PLC BASED, AUTOLOAD TRANSFER,, AUTO START AND AUTO STOP, AUTOLOAD BALANCING PANEL FOR 1 nos. 1010 kVA D.G. sets AND AUTO ON OF TRASNFORMER FEEDERS ONCE THE SUPPLY IS RESTORED, complete as required to acheive the desired functions.

-

-

-

... More
PLC shall be provided in main LT panel for interlocking between different incomers and bus couplers to avoid unintentional paralleling of different supplies.

-

-

-

... More
In addition to required hardware and software following components shall also be provided.

-

-

-

... More
Based on the load requirement only required no. of DG sets shall be operated.

-

-

-

... More
PLC Hardware as required

-

-

-

... More
Auxiliary relays/contactor/metering/protection etc as required

-

-

-

... More
230 V AC, UPS of suitable rating.

-

-

-

... More
Annunciators as required.

-

-

-

... More
One no. Battery charger set consisting of Transformer I Rectifier, DC ammeter, DC voltmeter, Charging rate selector switch, Offffrickle/boost.

-

-

-

... More
All control wiring from PLC to various feeders with min. of 2.5 sq mm copper FRLS cable.

-

-

-

... More
The PLC provided for Synchronisation, Load Management & for interlocking of Breakers shall perform to achieve the system as described in given Main Schemetic Diagram.

-

-

-

... More
OUTGOINGS-

-

-

-

... More
All outgoing feeders shall be provided with one set of phase indication lamps and on, off, trip indication lamps with protection fuses/MCB and ammeter with selector switch with suitable ratio CT's of accuracy class 1.0

-

-

-

... More
2 nos. 500 AMPS TP MCCB (CAPACITOR PANEL)

-

-

-

... More
2 nos. 630 AMPS FP MCCB (Production Building & spare)

-

-

-

... More
2 nos. 400 AMPS FP MCCB (PH & spare)

-

-

-

... More
2 nos. 200 AMPS FP MCCB (FG & Spare)

-

-

-

... More
1 nos. 200 AMPS FP MCCB (Residential Building-Power)

-

-

-

... More
1 nos. 160 AMPS FP MCCB (Residential Building- Light)

-

-

-

... More
6 nos. 100 AMPS FP MCCB (PH, LFC, MAIN GATE, STP & spare etc)

-

-

-

... More
SWITH BOARD COMPLETE WITH ALL INTERNAL WIRING, NAME PLATES AND COMPLETE IN ALL RESPECTS.

-

-

-

... More
CAPACITOR PANEL- 150 kVAR

-

-

-

... More
Supply, Installation, Testing commissioning, Design, manufacture, supply, inspection, handling, assembling, affecting proper connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type 250 kV AR APFC Panel consisting of 50 / 25/12.5 kVAR capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623.

1

275000

275000

... More
All outgoings MCCB's shall be thermal-magnetic based with inbuilt O/L & S/C release.

-

-

-

... More
All MCCB's shall be lcs = 100% lcu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip selling as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link. The breaking capacity specified is lcs value. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT's, PT'S, etc

-

-

-

... More
Capacitor duty contactors should be used for switching individual capacitor banks.

-

-

-

... More
The fault withstanding capacity of panel & its control gear shall be min. 50 kA rms for 1 sec.

-

-

-

... More
The capacitor panel shall be integrated with the main L T Panel as per schematic diagram.

-

-

-

... More
INCOMING

-

-

-

... More
Incomer circuit breaker has been included in the main panel.

-

-

-

... More
1 set- 3 CTs, ratio 200/SA Class 1.0 accuracy 15 VA burden for metering.

-

-

-

... More
1Nos- (0-500A) digital Ameter with selector switch

-

-

-

... More
Micro processor based automatic power factor control relay (including power factor meter) in 14 steps for automatic cut off or add on capacitor units to keep the power factor at 0.95 with variation of loads. All associated auxiliary contactors I relays shall be provided with in the scope of work.

-

-

-

... More
Phase indicating lamps with HRC fuses, and indicating in each capacitor chamber unit to indicate On/Off status of capacitor unit.

-

-

-

... More
BUS BARS

-

-

-

... More
400 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC/ DMC supports, with colour coding and insulated by heat shrinkable sleeves and clips on shrouds for joints. The current density of bus bar shall be minimum 1.00 sq mm / amp.

-

-

-

... More
The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above ambient temperature.

-

-

-

... More
OUTGOINGS-

-

-

-

... More
4 nos. of 125 AMPS TPN 25 kA MCCB and 150 amps AC3 duty contactor with 50 kVAR gas filled 415 V capacitor bank, auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete.

-

-

-

... More
2 nos. of 63 AMPS TPN 25 kA MCCB and 80 amps AC3 duty contactor with 25 kVAR gas filled 415 V capacitor bank, auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete.

-

-

-

... More
2 nos. of 32 AMPS TPN 25 kA MCCB and 40 amps AC3 duty contactor with 2x12.5 kVAR+ 5 nos. of 25 AMPS TPN 25 kA MCCB and 32 amps AC3 duty contactor with5X5kVAR gas filled 415 V capacitor bank, auto-manual selector switch, start stop push button for manual operation including on/off indicating lamps and delay timer complete.

-

-

-

... More
Bus Duct

-

-

-

... More
Supply, Installation, Including Suspention, Testing and Commisioning of Following Capacity Bus Trunking with Aluminium Bus Bar in 1.6mm Thick Sheet Steel Enclosed in convenient sections for use on 3 phase, 4 wire, 415 volts, 50 Hz, AC Supply including jointing of section flexible joints, expention joint, bends & earthing with 2 runs of galvanised iron strips, suspenders, angle iron bracket steel fastner, connecting to the earth system etc. as required.

-

-

-

... More
400A

25

187500

7500

... More
Bus Bar Trunking

-

-

-

... More
Supply, Installing on wall, Testing and Commisioning of Following Capacity Air Insulated Compact type Bus Bar Trunking for use 3 phase, 4 wire, 415V, 50 Hz, AC Supply with enclosure having IP 54 rating after fixing the tap-off boxes and all accessories made of 1.6mm thick sheet steel duly painted with powder coated in convenient sections complete with, 4 Nos. Aluminium Bus Bars having current density of 130A/ sq.cm at nominal current rating, necessary joints & expantion joints, fire proof barrier at each floors, provision of tapping at every meter, continuous earthing with 2 Nos. Aluminium strips of suitable size (one on each side) including GI clamping brackets, angle iron brackets, steel fastener, connecting to earthing system etc. as required.

-

-

-

... More
200 A, ISC = 15 kA for 1 Sec.

5

43518

8703.6

... More
ADMIN BUILDING PANEL BOARD

-

-

-

... More
INCOMER:

2

450000

225000

... More
1 Nos. 200A 4P MCCB's with microprocessor based releases ,ON indication1 no. multifunction meter (showing all power parameters), with selector switch, matching cast resin CT's.

-

-

-

... More
BUS BAR

-

-

-

... More
A set of TPN Aluminium bus bar with heat Shrink Sleeve rated for 250A (after considering all necessary deratings) 3 phase 4wire, 50Hz.

-

-

-

... More
A suitable minimum derating factor must be taken for calculation of bus bar sizes. The bus bar size after derating shall be equal to the ampere given in the BOQ.

-

-

-

... More
Maximum current density of 1 Amp per sq.mm is suitable for the busbar.

-

-

-

... More
OUTGOING

-

-

-

... More
63A FPX2 MCB

-

-

-

... More
4 nos 100 amp 25 kA TPN MCCB's with ON/OFFfTRIP indication lamp.

-

-

-

... More
1 Lot of control wiring

-

-

-

... More
1 Set of designation plates

-

-

-

... More
LIFT PANEL-1 (Admin Building)

-

-

-

... More
INCOMER:

1

138000

138000

... More
1 Nos. 150A 4P on load change over switch.

-

-

-

... More
1 Nos. 160A TPN feeder each having one no. 160A TPN MCCB's with microprocessor based releases with isolable neutral ,ON indication1 no. multifunction meter (showing all power parameters), with selector switch, matching cast resin Cl's.

-

-

-

... More
OUTGOING

-

-

-

... More
1 nos 32 A DP 10 kA MCB's.

-

-

-

... More
1 nos 63 A 4P 25 kA MCCB's with indication lamps

-

-

-

... More
1 nos 100 A 4P 25 kA MCCB's with indication lamps

-

-

-

... More
TVSS

-

-

-

... More
Supply, installation, testing & commissioning of 50 kA surge handling capacity TVSS with 10 mode protection including EMI & RFI filters in a wall mounted sheet steel powder coated enclosure with locable door and with 4P MCB/ 4P MCCB of 50kA fault with stand capacity and complete with wiring as required.

1

32999

32999

... More
SAFETY EQUIPMENT

-

-

-

... More
Supply, installation and fixing of the following equipment at suitable place in the sub-station building as required:-

-

-

-

... More
M.S bucket of 9 liters capacity painted with red oxide paint & lettered as 'Fire' with White and red mounted on freestanding stand, as required including filling with dry sand.

4

12489

3122.4

... More
First aid box as approved by india redcross society St. John Ambulance conforming to IS: 2217 -1963.

2

5970

2985

... More
Shock treatment chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English).

1

649

649

... More
Rubber Mat 914.4 mm wide and 12 mm thick checkered rubber mat to withstand 33 KV dielectric strength confirming to IS : 5424 -1969 complete as required.

10

24410

2441

... More
TELEPHONE SYSTEM

-

-

-

... More
Providing, fixing, connecting & testing of External type (IP 65) Telephone Tag Block krone type in a suitable size 1.6 mm thick dust and vermin proof Sheet steel enclosure duly painted by synthetic enamel over anti corrosive primer, lockable and hinged cover with provision for cable through glands complete in all respects.

-

-

-

... More
10 pair krone

3

1770

590

... More
20 pair krone

3

2190

730

... More
100 pair krone

1

4300

4300

... More
Supplying, laying, testing and commissioning of following size anealed tinned copper conductor PVC insulated and sheathed armoured copper telephone cables direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
10 pair

300

68100

227

... More
20 pair

400

136000

340

... More
100 pair

30

26850

895

... More
Supplying, installing, testing and commissioning of 48 Extension EPABX system including necessary fitting and accessories as per site requirement. Make: Kolhar NEC or equivalent.

1

125000

125000

... More
Providing and installation of caller ID corded landline phone with 16 digit LCD display and adjustable contrast, two ways speaker phone, 13 incoming and 5 outgoing memory along with necessary wiring and accessories as per requirement. Make: Beetel or equivalent

35

56000

1600

... More
External Lighting Panel (IP-56)

-

-

-

... More
INCOMER:

-

-

-

... More
1 No. 63A MCB FP

1

51000

51000

... More
01 Timer

-

-

-

... More
1 X 40A Contactor

-

-

-

... More
25A SP X 3 MCB

-

-

-

... More
Indicating Light X 3

-

-

-

... More
6A MCB X 3

-

-

-

... More
Connector X 10

-

-

-

... More
EXTERNAL LIGHTING WORKS

-

-

-

... More
LT CABLE AND ACCESSRIES

-

-

-

... More
SUPPLY OF L.T. CABLE:

-

-

-

... More
Supplying of following sizes of 1.1 kV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required.

-

-

-

... More
2C x 6 Sq.mm Al. XLPE arm.

300

25560

85.2

... More
4C x 10 Sq.mm Al. XLPE arm.

150

19980

133.2

... More
4C x 16 Sq.mm Al. XLPE arm.

100

15000

150

... More
EXTERNAL LIGHTING

-

-

-

... More
SUPPLY OF EXTERNAL LIGHTING SYSTEM

-

-

-

... More
Supply of Pole mounted 120W LED Street Light, luminous efficiency of luminaire 2 100 Im/W & total Lumen Output of 6000Lm, colour rendering index Ra 70. Service life L70(tq 25 °C) = 50,000 h. Pressure die cast aluminium painted mounting spigot suitable for horizontal mounting with tilt flexibility of +/- 10 degrees & wide photometry, Ingress Protection rating IP66 & impact resistance of IK08. Power Factor 2 0.95, THD should be s 10%. Surge protection should be 2 10kV. All luminaires shall be with associated driver, lamp and other connecting or mounting accessories to make it complete in all respect for operational purpose. Make: Havells or equivalent

24

392817

16367.4

... More
Supply, installation, testing and commission of the pole shaft shall be made single piece MS structure continuously tapered having polygonal (8/12 sides) cross section and a single longitudinal welding.Top dia 70mm and bottom dia 130 mm, thickness 3mm , height 3m. The welding will be done as per BS 5135 / IS 9595. No circumferential welding shall be allowed in the pole shaft. The MS shall confom to BSEN 100025/100027. The structure shall be single hot dip galvanized as per BS 729 / IS 2629. A suitably designed door shall be provided at approximate 700mm height from the pole base. The door opening will be suitably reinforced for structural strength. The door shall be flushed with pole external surface and shall provide easy access for electrical connections at a maintainable height. A Suitable base flange will be welded and plate reinforcements will be provided between base flange & pole. Base Plate 220x 220 x 16mm Foundation accessories will be as per IS 1367 of TRILUX LSL-6000 ET.

24

269136

11214

... More
Supplying, drawing, connecting and testing of following size of PVC insulated FRLS copper conductor (as per IS : 694) flexible multicore wire in the existing poles and bracket from cable termination connector / MCB to the fitting i/c providing suitable connectors.

-

-

-

... More
3 core 2.5 sq.mm (for 9 Mtr Poles)

500

47750

95.5

... More
Roof Top Solar

-

-

-

... More
Supplying, installation, connecting, testing & Commissioning of on grid solar plant which consist of following:

-

-

-

... More
50 kW grid-tie Inverter.

1

263500

263500

... More
540 Wp monohalf cut mono bifacial, PV Modules.

92

1830800

19900

... More
Conduit pipe UV protected, DCDB box ACDB box with MCCB, 6 mm DC wire, MC4 connectors, 1 nos ESE lighting arrester, 16 mm aluminium cable for earthing, 3 mtr GI mask for L.A., GI Chemical 58 mm dia for earthing

1

975000

975000

... More
Galvanised Iron Mounting Structure along with Foundation and necessary accessories and fittings as per requirement

35

523250

14950

... More
Installation, connection, testing & Commissioning of entire system including all related supplies complete as per site requirement.

1

275000

275000

... More
CCTV Camera System

-

-

-

... More
4MP IP Bullet Camera. Make: CP Plus or equivalent

30

176250

5875

... More
VMS Software for 128 Cameras for live view/playback. (We will provide the sofware given by CP Plus through a link which is generated after taking the server MAC Address and then the software is provided to you in a Pen drive). Make: CP Plus or equivalent

1

295000

295000

... More
Desktop Server with Intel i7 Processor, 16GB RAM, Windows 11 or compatible, SSD 500GB, Gigabyte Motherboard complete with Keyboard and Mouse, Hard Disc 4 Terabyte, Graphics Card with Antivirus or better which supports the VMS.

2

163848

81924

... More
32 Channel NVR with 4 SATA support. Make: CP Plus or equivalent

1

28914

28914

... More
Surveillance Hard Disc 8TB. Make: WD/Seagate or equivalent

2

37900

18950

... More
4 Port Gigabit POE Switch. Make: Dlink or equivalent

4

25056

6264

... More
8 Port Gigabit POE Switch. Make: Dlink or equivalent

4

38552

9638

... More
5 Port Gigabit Network Switch. Make: Dlink or equivalent

3

8142

2714

... More
8 Port Gigabit Network Switch. Make: Dlink or equivalent

2

16166

8083

... More
Outdoor Weatherproof PVC Box with inbuilt supply board.

10

17460

1746

... More
PVC Box for Camera.

30

14430

481

... More
Metal Cage for Outdoor Cameras.

12

20532

1711

... More
Server Rack 42U with PDU, Fan, tray, cable manager etc. Make: Digirack or equivalent

1

48190

48190

... More
Mount for Bullet Camera for Pole.

12

17340

1445

... More
55” HD LED TV. Make: Samsung or equivalent

2

126720

63360

... More
Media Convertor.

10

73160

7316

... More
Fibre Junction Box with Accessories.

8

41536

5192

... More
2” MS Pole for Cameras, pole height 15' length with pole fixing and Civil work.

10

94750

9475

... More
12 Core Fiber Cable.

1200

106200

88.5

... More
Installation and Configuration Charges of IP Cameras

30

57180

1906

... More
Cat-6 Cable 4 Pair. Make: Dlink or equivalent

700

26600

38

... More
Outdoor Cat-6 Cable 4 Pair. Make: Dlink or equivalent

500

37500

75

... More
2-Core 1.5 sq.mm. Supply Cable. Make: Polycab or equivalent

1700

130900

77

... More
Cable Laying charges on surface

3800

133000

35

... More
Cable Laying charges underground/in soft soil

300

166500

555

... More
Splicing Charges for Fiber Cable

50

43700

874

... More
VMS Software Installation, System Integration and Configuration Charges

1

72287

72287

... More
Online UPS 6KVA with 7AH 12 V* Battery with alarms like overload, overcharge, low battery, discharge protection (*or as applicable for existing system. Make: BPE or equivalent

1

93810

93810

... More
PVC Pipe with accessories. Make: ISI Medium

1700

96900

57

... More
Support Wire.

1000

28000

28

... More
CCTV – Surveillance Signage’s (Throughout the Campus- Inside & outside).

30

20550

685

... More
TRANSFORMER

-

-

-

... More
Supply, Installation & Testing Commissioning of Outdoor Type Oil cooled ONAN, 160 kVA, 3 Phase, 50Hz, Dyn11 vector group, copper wound, Transformer with Off Load Tap Changer with Tap Range + 5 to - 10 in steps of 2.5 % having cable end box on HV side suitable of 3.5C x 240 sq. mm. XLPE cable of 33 kV grade and 800A Busduct on LV side complete with marshalling gox, Buchholz relay all accessaries conforming to specifications. The insulation class A class and temp rise shall be limited to 35 in Oil 45 in winding OTI, WTI with trip alarm contact. Transformer Impedance, No Load Losses, Load Losses etc. tolerance as per IS 1180 Level-2.

1

624000

624000

... More
All instruments Contact wiring to be done up to Marshalling box.

-

-

-

... More
Installation & testing shall be done by the electrical contractor in the presence of engineer in charge.

-

-

-

... More
The supplier shall certify that the Transformer has installed as per norms.

-

-

-

... More
Supplying & installation of 2.02 ton, 3 star, inverter split AC Make: Daikin or equivalent.

30

2098500

69950

... More
Laying of copper piping for split AC along with necessary accessories such as floor stand etc. for each split AC

30

273750

9125

... More
External Fire Fighting System 

-

-

-

... More
Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :

-

-

-

... More
4 way - 150 mm dia M.S. Pipe

1

14697

14697

... More
Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

1

19149

19149

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (Above ground)

-

-

-

... More
150 mm. Dia

800

1756000

2195

... More
80mm Dia

24

28632

1193

... More
100mm dia

24

38256

1594

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (Pump room )

-

-

-

... More
80 mm dia

6

6732

1122

... More
100 mm dia

6

9564

1594

... More
150 mm dia

12

26340

2195

... More
200 mm dia (wall thickness 6.3 mm)

6

18666

3111

... More
Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required. having calibration of 0-15 Kg/cm2.

8

11480

1435

... More
Supply, Installation, Testing & Commissioning G.I/M.S class 'C' puddle flange to sumps/RCC tanks, complete as per drawing.

-

-

-

... More
150mm dia

1

6750

6750

... More
100mm dia

1

5950

5950

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

15

20595

1373

... More
Providing & fixing cast iron Foot valve with nuts, bolts, 1.5 mm thick CAF gasket complete with all accessories (To be provided into UG Fire Water Tanks)

-

-

-

... More
100 mm dia

3

16890

5630

... More
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators suitable for raw water upto 45 deg. C. temperature working pressure 7 kg/sq.cm and test pressure 14 kg/sq.cm.

-

-

-

... More
100 mm dia

1

6410

6410

... More
150 mm dia

2

16240

8120

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body,brass/ bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :

-

-

-

... More
150mm dia

3

152790

50930

... More
Under Ground Piping

-

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239 /3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.

-

-

-

... More
150 mm dia

50

126300

2526

... More
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.

1000

220000

220

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.

-

-

-

... More
700 mm

200

285200

1426

... More
1000 mm

150

245550

1637

... More
1200 mm

150

260400

1736

... More
150 mm dia gun metal Fire Brigade Suction Hose Coupling

-

-

-

... More
150 mm dia

1

5600

5600

... More
Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
80 mm dia

3

15444

5148

... More
100 mm dia

3

20589

6863

... More
150 mm dia

5

46250

9250

... More
200 mm dia

2

31810

15905

... More
Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :

-

-

-

... More
80 mm dia

2

16032

8016

... More
100 mm dia

2

23044

11522

... More
150 mm dia

3

56070

18690

... More
Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.

-

-

-

... More
200 mm dia

1

23448

23448

... More
Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts.

4

3180

795

... More
Supplying and installing at approved location approved make Fire Buckets of 24 gauge galvanized steel sheet, standard of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets).

-

-

-

... More
4 nos.Fire Bucket Without canopy

5

22500

4500

... More
Providing and Fixing M.S Structural Work fabricaed from standard sections e.g MS rounds, angles, channels including cutting to size, drilling, welding, fixing and welding to insert plates in RCC structural members as directed by Engineer-in-Charge including cutting and making good the walls and floors (For sprinkler Pipe support etc.).

-

-

-

... More
Angle Frame 35 / 40 mm x 5 mm

350

31500

90

... More
Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required.

3

4809

1603

... More
Providing,fixing,testing & commissioning of M.S.class 'C' diesel pump exhaust pipe including all fittings like bends, tee, clamps/structural steel support of suitable dia for the engine. The insulation of the exhaust pipe shall be carried out with rock wool with specific gravity of 100kg/cm2 and cladded with 22 gauge aluminium sheet complete with all fittings & accessories. Make: Tata/Zindal.

-

-

-

... More
50 mm dia

24

20400

850

... More
Providing & fixing cast iron Air Release Valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement.

4

8372

2093

... More
Fire Pump Set

-

-

-

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :

-

-

-

... More
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.

-

-

-

... More
Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.

-

-

-

... More
M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.

-

-

-

... More
Suitable cement concrete foundation duly plastered with anti vibration pads.

-

-

-

... More
2280 lpm at 70 m Head

1

390546

390546

... More
(Note : The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.)

-

-

-

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : Diesel Driven Pump Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.

-

-

-

... More
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
2280 lpm at 70 m Head

1

648929

648929

... More
(Note : The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.)

-

-

-

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : Jockey Pump

-

-

-

... More
Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.

-

-

-

... More
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325.

-

-

-

... More
M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.

-

-

-

... More
180 lpm at 70 m Head

1

108872

108872

... More
Electrical Pannel for Fire Pumps :

-

-

-

... More
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :

-

-

-

... More
Incoming :

-

-

-

... More
250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc.

-

-

-

... More
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps

-

-

-

... More
Set of Copper Bus Bar 300A

-

-

-

... More
Outgoings :

-

-

-

... More
( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps).

-

-

-

... More
Main Fire Pump :

-

-

-

... More
125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation,selector switch for local/remote, auto/manual/OFF operation. - 1 Sets

-

-

-

... More
Jockey Pump :

-

-

-

... More
63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 1 Sets

-

-

-

... More
Diesel Engine Control :

-

-

-

... More
Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine.

-

-

-

... More
System Controller :

-

-

-

... More
Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification

1

261285

261285

... More
Fire Alarm & Fire Fighting System 

-

-

-

... More
Fire Alarm System :

-

-

-

... More
Supplying, installation, testing and commissioning of Agani make fire alarm system

-

-

-

... More
8 Zone

1

9786

9786

... More
Supplying, installation, testing & commissioning of Siren with 2km range

1

8100

8100

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required.

1

2510

2510

... More
Supplying, installation, testing & commissioning of manual call point complete as required.

18

43380

2410

... More
Supplying, installation, testing & commissioning of hooter

12

13800

1150

... More
Supplying, installation, testing & commissioning of Fire alarm armoured cable 1.5X2 core with neccessary clamp. strobe complete as required.

1200

150000

125

... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with two loop LCD display with touch screen or other keypad fitted with dual loop card, basic configuration upto 508 addressable devices with facility to connect printer to printout log and facility to have communication card with minimum 1000 fire event history law in the non-volatile memory, 10000 general event, power supply unit (240 +/- 10% V, 50/60 HZ), and necessary batteries (2X12Volt/24AH) and the panel shall be complete with all accessories.

1

234950

234950

... More
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.

1

121500

121500

... More
Supplying, installation, testing & commIssIoning of intelligent analog addressable photothermal detector complete with mounting base com ete as required.

25

65375

2615

... More
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.

10

17560

1756

... More
Supplying, installation, testing & comm1ss1oning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.

30

6150

205

... More
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.

5

19175

3835

... More
Supplying, installation, testing & commisssioning of intelligent addressable horn cum strobe complete as required.

5

14950

2990

... More
Supplying, installation, testing & commissioning of fault isolator complete with base as required.

30

85350

2845

... More
Supplying, installation, testing & commissioning of fire fighter telephone handset com ete as required.

2

9800

4900

... More
Supplying, installation, testing & commissioning of fire fighter phone jack com ete as required.

3

3375

1125

... More
Supplying, installation, testing & commissioning of repeater panel wih 320 character/Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.

1

77500

77500

... More
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

200

37440

187.2

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface/ recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.

-

-

-

... More
speaker cable Single pair, 2-core, 1.5 sqmm

500

29400

58.8

... More
Supplying, installation, testing & commissioning of exit point directional sound speaker with voice and integral audio amplifier with selectable sound pulse patterns complete as required.

4

39980

9995

... More
Supplying, installation, testing & comm1ss1oning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required.

2

112000

56000

... More
Fire Fighting System :

-

-

-

... More
Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site.

24

6000

250

... More
FIRE EXTINGUISHERS

-

-

-

... More
Providing and fixing Carbon-di-oxide fire extinguishers made from brand new seamless cylinder as per IS: 7285 and CCE approval fitted with discharge, Bend and Horn and Squeeze Grip / wheel type valve with initial charge as per IS:15683:2006 specification, bearing ISI Mark & EIL approved.

-

-

-

... More
4.5kg.Capacity

10

81250

8125

... More
Providing and fixing ABC Stored Pressure type Fire Extinguisher bearing ISI Mark for Fighting ABC Class of Fire. The Extinguisher will be Manufactured Strictly as per BIS: 15683:2006 bearing ISI. mark. EN3 615 Approved Powder. ABC 87% MAP. Valve with below mentioned additional facilities a) In built NRV on valve to cross check internal pressure. b) Operating temperature marking on valve. c) Automatic safety release valve. d) Non Returnable Valve

-

-

-

... More
4kg.Capacity

10

29000

2900

... More
Internal Hydrant System

-

-

-

... More
Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :

-

-

-

... More
Single headed S.S 304

16

101856

6366

... More
Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :

-

-

-

... More
S.S 304

32

150880

4715

... More
Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :

-

-

-

... More
S.S 304

16

28032

1752

... More
Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.

-

-

-

... More
30 m

16

143136

8946

... More
Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :

-

-

-

... More
2 way-100 mm dia M.S. Pipe

1

7007

7007

... More
Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

2

38298

19149

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
25 mm dia

850

425850

501

... More
65 mm dia

84

89712

1068

... More
80 mm dia

84

100212

1193

... More
100 mm dia

84

133896

1594

... More
Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required. having calibration of 0-15 Kg/cm2.

6

9870

1645

... More
Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
100 mm dia

6

41178

6863

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :

-

-

-

... More
Pendent Sprinkler

510

262650

515

... More
Providing & fixing Flow Switch in following sizes M.S. pipe including connection etc as required.

-

-

-

... More
150mm dia

1

9430

9430

... More
Providing and fixing MS cabinet (size 600 x 450 x 150 mm) fabricated from 16 gauge MS sheet with full front glass door & locking arrangement with suitable shelves for keeping 36 Nos. spare sprinklers & one no. spanner properly fixed in shelves. Cabinet shall be painted with enamel paint of approved shade.

16

71680

4480

... More
Providing & fixing cast iron Air Release Valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement.

6

12558

2093

... More
SEWAGE TREATMENT PLANT (MBBR Technology)-5 KLD

-

-

-

... More
Design, supplying, installing, testing & commissioning of Sewage Treatment Plant cum Effluent Treatment Plant in RCC construction (including excavation, back filling & disposal of surplus earth MS/Civil construction work) for the following duty:

1

950000

950000

... More
Nature of effluent - Domestic Sewage from toilet, kitchen waste water shall be discharged into the STP.

-

-

-

... More
Daily Average flow - 5 Cum / Day

-

-

-

... More
Sewage Characteristics

-

-

-

... More
pH - 6.5-8.5

-

-

-

... More
BODS - 250 - 350 Mg/L

-

-

-

... More
S. Solids - 150 - 300 Mg/L

-

-

-

... More
COD - 400 - 600 Mg/L

-

-

-

... More
Oil & Grease - 20 - 50 Mg / L

-

-

-

... More
Effluent discharge standard after treatment

-

-

-

... More
pH - 7.0-8.5

-

-

-

... More
BODS - Less than 5 Mg/L

-

-

-

... More
S. Solids - Less than 5 Mg/L

-

-

-

... More
COD - Less than 40 Mg/L

-

-

-

... More
Oil & Grease - Less than 2 Mg/L

-

-

-

... More
Sewage treatment plant shall include the following items:

-

-

-

... More
Grit chamber - 1 No.

-

-

-

... More
Screen Chamber - 1 No.

-

-

-

... More
Sewage equalization tank / sump - 1 No.

-

-

-

... More
MBBR Reactor Tank - 2 nos.

-

-

-

... More
Supernatant Tank - 1 No.

-

-

-

... More
Secondary Tube Settler Tank - 1 No.

-

-

-

... More
Sludge Holding Tank - 1 No.

-

-

-

... More
Filtration through MGF & ACF

-

-

-

... More
Air Blowers, Pumps & equipment

-

-

-

... More
Piping, valves etc

-

-

-

... More
Instrumentation, Electrics, Electrical Panel & Cabling etc complete

-

-

-

... More
Note: Contractor shall ensure submission of detailed GA drawings (Plan & Section), P&I diagram, schematic diagram for the above said component and additional component if so required for the complete working of the STP for the full capacity.

-

-

-

... More
Passenger Elevator

-

-

-

... More
Design, manufacturing, testing at works, supply and delivery, receiving, unloading, storing, inspection, handling, assembling, installing in correct assigned position, effecting proper connections, testing and commissioning of Elevator of 15 passenger/1020 Kg. MRL with variable voltage variable frequency drive having a speed of 1 metre/ sec with 2 Stops, 2 opening same side, approx. 900 mm Door Width, 2000 mm Height, car dimentions of 1600 mm X 1500 mm X 2200 MM and ACD5-MRL controler type suitable for operation with VF regenerative drive closed loop 415 V, 50 Hz, 3 phase A.C. electric supply as required with Car, Central Opening Car Door & other features with all associated electrics & civil works as per requirement at site, CPWD General Specifications and as given in TS inclusive of ARD with Dry Maintainance free Battery. This also includes charges towords maintenance of 12 months from tha date of completed installation and handing over of the lift. Make: OTIS

1

2592923

2592923

... More
DIESEL GENERATOR SETS:

-

-

-

... More
D.G. SETS:

-

-

-

... More
Supply, intastallation along with foundation, unloading, cabling, exhaust piping, testing & commissioning of (100+100) kVA Capacity DG Sets with synchronisation with suitable capacity engine directly coupled with alternator for 415 volt, 3 phase, 50 Hz, 4 wire, generation system complete for each DG set with accessories, fuel oil tank & control panel etc as required and sound proof acoustic enclosure for the DG SETs, including provision of conrol cable from engine to control panel to engine. Provision of pipe fuel pipe line of suitable size fron fuel tank to engine and over flow pipe engine to fuel tank complete gate valve and fitting leader maker etc. Supplying and installation of AMF panel suitable for 100 KVA DG set, GI chemical earthing, change over at 160 Amp TPN onload changeover with enclosure, power panel, auto on/off, additional electric battery charger all as required and as directed by engineer incharge. Make Kirloskar or equivalent

1

3655682

3655682

... More
Total

-

204416245

-

... More
Add @ 2% Contingencies

-

4088324

-

... More
Grand Total

-

208504570

-

... More
Above/Below/At Par in %

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.