Nalanda University Tender

With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

Nalanda University - NU Tender

Works
Eprocure
Opening Date9 Nov 2018
Closing Date29 Nov 2018
Tender Amount₹ 24,40,09,682 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply Installation Testing and Commissioning of Data Networking CCTV Fire Alarm System, and Access Control system for all the Building and the overall Infrastructure for the Permanent Campus of Nalanda University NU Nalanda, Rajgir, Bihar.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SITC of single F/UTP CAT6A I/O of specified make including mounting inside singlex or duplex or quad faceplate and MS backbox assembly as required as per drawing, inclusive of termination of F/UTP CAT6A cable at each IO at workstation area/device.

5536

-

339

... More
SITC of singlex faceplate and corresponding MS backbox assembly for installation of 1 F/UTP CAT6A IOs

2809

-

115

... More
SITC of duplex faceplate and corresponding MS backbox assembly for installation of 2 F/UTP CAT6A IOs

1365

-

141

... More
SITC of quad faceplate and corresponding MS backbox assembly for installation of 4 F/UTP CAT6A IOs

100

-

151

... More
SITC of F/UTP CAT6A RJ-45/RJ-45 Patch Cords Solid Conductor of various lengths 3ft - IO side

5533

-

193

... More
SITC of F/UTP CAT6A RJ-45/RJ-45 Patch Cords Solid Conductor of various lengths 7ft- Rack side

5533

-

218

... More
SITC of F/UTP CAT6A RJ-45/RJ-45 Patch Cords Solid Conductor of various lengths 10ft- as required

100

-

254

... More
PVC Conduits Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm size.

1000

-

90

... More
PVC Conduits of 40 mm size. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 40 mm size.

1000

-

130

... More
FIBER OPTIC CABLE & COMPONENTS SITC and Laying of fiber optic cable of various capacities to be laid in prelaid conduits/RCC hume pipes/HDPE/DWC/cable trays/trenches/in underground soil, as applicable, excluding the cost of soft-soil or hard-soil digging. 12 cores, Singlemode, Outdoor, Armoured

10125

-

320

... More
12 cores, Singlemode, Outdoor, Armoured (For Electrical HT side Scada Integration)

25000

-

320

... More
12 cores, Singlemode, Outdoor, Armoured (FAS Panels Integration)

7500

-

320

... More
24 cores, Singlemode, Outdoor, Armoured

8400

-

381

... More
48 cores, Singlemode, Outdoor, Armoured

12400

-

598

... More
12 cores, Singlemode, Indoor, Unarmoured

1000

-

270

... More
SITC of wall mounted LIU of various capacities for optical splicing/termination of fiber optic cable as per the design schematics. It shall be complete with adaptor panels, adaptors and splice trays for using LC type termination and masking/blanking/dust cover for unused/unmounted adaptor ports, inclusive of all mechanical accessories. Adequate splice trays shall be provided for proper management of splices for required number of cores at every LIU. for 12 cores, Singlemode LC termination

10

-

11938

... More
for 24 cores, Singlemode LC termination

10

-

13604

... More
for 48 cores, Singlemode LC termination

10

-

19524

... More
SITC of 19" rack mounting type fiber shelf of various capacities for assembly/termination of fiber optic cable for LC style components, for optical splicing and provision for storage of pigtails and splices, equipped with adaptors, adaptor plates and any other such all necessary hardware for proper dressing and management of fiber optic cable. Any blank adaptor positions must be suitably masked for restricting dust entry. Adequate splice trays shall be provided for proper management of splices for required number of cores at every LIU. for 12 cores, Singlemode LC termination

210

-

11938

... More
for 24 cores, Singlemode LC termination

5

-

15161

... More
for 48 cores, Singlemode LC termination

7

-

20620

... More
SITC of LC-LC duplex fiber optic patch cords of various lengths 1 mtr/3 ft., singlemode

448

-

2146

... More
2 mtr/6 ft., singlemode

5

-

2617

... More
3 mtr/10ft., singlemode

5

-

3300

... More
SITC of LC type pre-terminated fiber optic cable pigtails of various lengths 1 mtr/3 ft., singlemode

878

-

536

... More
2 mtr/6 ft., singlemode

5

-

654

... More
3 mtr/10ft., singlemode

5

-

824

... More
Splicing / Termination of Fiber Optic Fiber Cable Cores using Fusion splicing with pre-terminated LC pigtails, dressing and proper fixing in splice trays.

3374

-

325

... More
SITC of IP66 rated External Splicing Kit for 96 cores inclusive of splicing of cores.

20

-

77190

... More
Suppy and Installations of OFC markers along the path of Fiber Distribution path for Identification of Fiber cable

100

-

435

... More
NETWORKING ENCLOSURES SITC of 19" wide mounting frame Networking Enclosures of various sizes and capacities complete with all accessories. 6U, 600mmW x 450mmD, wall mounted, 2 x 90cfm fans

49

-

4957

... More
9U, 600mmW x 450mmD, wall mounted, 2 x 90cfm fans

19

-

5265

... More
12U, 600mmW x 600mmD, wall mounted, 2 x 90cfm fans

72

-

9520

... More
15U, 600mmW x 600mmD, wall mounted, 2 x 90cfm fans

14

-

11787

... More
22U, 800mmW x 800mmD, floor mounted, 4 x 90cfm fans

3

-

26657

... More
36U, 800mmW x 800mmD, floor mounted, 4 x 90cfm fans

2

-

31988

... More
42U, 800mmW x 1000mmD, floor mounted, 4 x 90cfm fans

14

-

54499

... More
42U, 1000mmW x 1000mmD, floor mounted, 4 x 90cfm fans

1

-

64122

... More
ACTIVE: NETWORKING SWITCHES AND OPTIONS TYPE-1 (ACCESS SWITCH) SITC of Layer 2 manageable networking switch, 8 # 10/100/1000Tx ports, all ports capable of providing PoE+ as per 802.3at, switch having a PoE power budget of minimum 350 Watts, minimum 2 dedicated SFP ports.

68

-

37332

... More
TYPE-2 (ACCESS SWITCH) TYPE-2 (ACCESS SWITCH) SITC of Layer 2 manageable networking switch, 24 # 10/100/1000Tx ports, stacking, all ports capable of providing PoE+ as per 802.3at, switch having a PoE power budget of minimum 350 Watts, minimum 4 dedicated SFP ports. All ports should be active simulatneously

318

-

70311

... More
TYPE-3 (DISTRIBUTION SWITCH) SITC of Layer 3 fiber aggregation networking switch, minimum 24 # SFP ports, plus minimum 4 # SFP+ ports, 1 AC power supply built in and inclusive of at least 1 redundant power supply and redundant fans.

10

-

287816

... More
TYPE-4 (CORE SWITCH) Supply, Installation, Testing and Commissioning of Core Switch, minimum 24 # SFP+ ports inclusive of and installed with the following features: redundant power supply, redundant fans, full advanced Layer 3 features, switch virtualization and high availability.

2

-

1584363

... More
SITC of 1000 Base LX singlemode tranceivers for L2/L3 switch, duplex LC termination supporting distance upto 2000 mtrs for ACCESS SWITCHES.

440

-

32484

... More
SITC of 1000 Base LX singlemode tranceivers for L2/L3 switch, duplex LC termination supporting distance upto 2000 mtrs for DISTRIBUTION SWITCHES.

64

-

32484

... More
SITC of 10G SFP+ LR singlemode transceivers, 1310nm, duplex LC termination supporting distance upto 2000 mtrs, inclusive of any hardware or interfaces such as modules for populating SM-LC transceivers for DISTRIBUTION SWITCHES.

40

-

130424

... More
SITC of 10G SFP+ ER singlemode transceivers, 1550nm, duplex LC termination supporting distance upto 10000 mtrs, inclusive of any hardware or interfaces such as modules for populating SM-LC transceivers for DISTRIBUTION SWITCHES.

32

-

326468

... More
SITC of 10G SFP+ LR singlemode transceivers, 1310nm, duplex LC termination supporting distance upto 2000 mtrs, inclusive of any hardware or interfaces such as modules for populating SM-LC transceivers for CORE SWITCHES.

32

-

130424

... More
SITC of wireless controller capable of supporting min. 1000 access points, inclusive of licence costs for 1000 Access Points. Centralized Hardware Controller based architecture. The system shall operate in High Availability (HA) mode providing redundancy for controller hardware.

2

-

2844612

... More
SITC of Wireless Access Point supporting Dual band with 802.11ac (5 GHz) and 802.11g/n (2.4GHz) concurrent operation, 4 x 4:3 MIMO Wave2 from Day 1, One 10/100/1000 Base-Tx auto-sensing (RJ45) PoE port. The AP shall be wall mountable as well as ceiling mountable (provide both options).

957

-

37126

... More
SITC of licences for supporting every additional 100 wi-fi APs (in slab of 100 Nos.)

1

-

1376193

... More
SITC of Management Tool for Centralised Configuration, Administration, Fault and Performance Monitoring and Virtualisation Management for wired and wireless LAN infrastructure. (NMS)

1

-

2064248

... More
2. VIDEO SURVEILLANCE / CCTV SYSTEM SITC of Full High Definition Network Cameras, outdoor PTZ, 1/3" CMOS/MOS/CCD sensor with 30x optical zoom or better, minimum resolution 2MP (1920X1080) or better, high speed dome, 360 degrees full rotation, complete with IK10 rated vandal resistant and IP66 rated weatherproof housing, PoE+ as per 802.3a/f/t or including an optional AC/DC supply if required, supporting True Day/Night operation, ONVIF Profile S compliant, supporting H.264 High Profile with dehumidification feature.

14

-

85979

... More
SITC of Full High Definition Network Cameras, indoor PTZ, 1/3" CMOS/MOS/CCD sensor with 30x optical zoom or better, minimum resolution 2MP (1920X1080) or better, high speed dome, 360 degrees full rotation, complete with IK10 rated vandal resistant housing, PoE+ as per 802.3a/f/t or including an optional AC/DC supply if required, supporting True Day/Night operation, ONVIF Profile S compliant, supporting H.264 High Profile with dehumidification feature.

10

-

66999

... More
SITC of Full High Definition Network Cameras, Fixed Dome, 1/3" CMOS/MOS/CCD sensor, 3-8 mm lens, minimum resolution 2MP (1920X1080), 1080p resolution at frame rates 30fps or better, H.264 High Profile, JPEG/MJPEG support, True Day/Night operation, ONVIF Profile S compliant, complete with IK10 rated vandal resistant housing and Power on Ethernet (PoE) based on 802.3a/f.

723

-

35011

... More
SITC of AutoCAD Design Studio AutoCAD for 10 users along with Development of the specialized tools (minimum 100 nos drafted by the supplier and approved by NU Engineer) AutoCAD library in Architectural, Mechanical, Electrical, Plumbing and Civil Engineering. This should have its own local network for the 10 users however the I/o points and data cable networking in the project building shall be provided by the University or it should be able to run on the existing LAN/WAN. The Licence has to provide password protected cloud support for tertiary backup of the drawings. The secondary backup shall be on the local network along with 100TB space for storage of the design studio based documents/drawings through its local server. The supplier has to provide the operation manual and hands-on training on the system. .

1

-

1000000

... More
SITC of Full High Definition Network Cameras, Outdoor CS-Mount type, 1/3" CMOS/MOS/CCD sensor, 5-50mm varifocal lens, minimum resolution 2MP (1920x1080), 1080p resolution at frame rates 30fps or better, H.264 High profile, JPEG/MJPEG support, Day/Night operation, ONVIF Profile S compliant, complete with IK10 rated vandal resistant and IP66 rated outdoor housing and Power on Ethernet (PoE) based on 802.3a/f.

16

-

37755

... More
SITC of Full High Definition Network Cameras, indoor CS-Mount type, 1/3" CMOS/MOS/CCD sensor, 3-8mm varifocal lens, minimum resolution 2MP (1920x1080), 1080p resolution at frame rates 30fps or better, H.264 High profile, JPEG/MJPEG support, Day/Night operation, ONVIF Profile S compliant, complete with IK10 rated vandal resistant housing and Power on Ethernet (PoE) based on 802.3a/f.

74

-

35156

... More
SITC of Video Management Software with ONVIF Profile S compliance having licenses for 1000 cameras and scalable to additional 50% cameras in future by adding appropriate licenses, i.e., without adding any hardware or software and inclusive of 10 client licences..

1

-

2313718

... More
SITC of Server(s) required for the VMS - Industry standard Intel Xeon Dual Processor, both pocessors installed, 16 GB RAM, 1 x 1TB GB SATA HDD for OS and VMS applications, 2 x GiG NIC, DVD ROM Drive, Appropriate Licensed Operating Systems.

1

-

268769

... More
SITC of Recording Server(s) - Industry standard Intel Xeon Dual Processor, both pocessors installed, 16 GB RAM, 1 x 1TB GB SATA HDD for OS and VMS applications, 2 x GiG NIC, DVD ROM Drive, Appropriate Licensed Operating Systems. Vendor shall provide required no. of servers for supporting the total no. of cameras as above, however not exceeding 64 cameras per server (1 no. of spare server shall be provided in addition to the required qty. of servers). Set of servers shall be supplied with 16-port KVM switch, USB/Wireless Keyboard, USB/Wireless Mouse, 1 x 21" LED Monitor.

1

-

2743667

... More
SITC of Network Storage required with a capacity to store the content for 1000 cameras for 24Hrs x 30days at 25fps and 1080p. It should be scalable (should have sufficient expansion bays for HDDs) for at least additional 50% cameras. Vendor shall submit bandwidth and storage calculator for the proposed camera models.

1

-

7217524

... More
SITC of Client with Intel Core i7 870 or higher with 8 GB of RAM DDR3, 1 TB SATA II hard drive for OS and VMS applications, 1 GB PCI-Express x16 dual-head video adapter supporting DVi or HDMI outputs, 1600 x 1200 or higher screen resolution, 100/1000 Ethernet Network Interface Card and 16x DVD+/- RW Drive along with appropriate Operating System, inclusive of minimum 32'' LED display compatible with supplied video adaptor.

5

-

63058

... More
SITC of narrow bezel Professional Display/Monitors min. 55" diagonal HD LED display, min. 1 x HDMI/DVi, 2 x HDMI, USB, these shall be supplied with all hardware and mechanical work/assembly required for panelling and video wall matrix type mounting configuration as per site requirements.

5

-

138108

... More
SITC of A3 sized laser color printer with required accessories and hardware as required.

2

-

21156

... More
FIBER COMPONENTS FOR OUTDOOR CCTV SITC and Laying of outdoor 12 core armoured single mode fiber optic cable for outdoor connectivity where ever required in prelaid conduits / RCC hume pipes/HDPE/DWC, whichever maybe available, including the cost of soft-soil or hard-soil digging and remaking of soil. read with corrigendum.

10000

-

320

... More
SITC of 12 Port outdoor LIUs for fiber terminations.

12

-

10276

... More
SITC of LC-LC single mode duplex fiber optic patch cord 1mtr as per tender specification.

12

-

2146

... More
SITC of LC type single mode pre-terminated duplex pigtail 1mtr as per tender specification.

12

-

536

... More
Suppy and Installations of OFC markers along the path of Fiber Distribution path for Identification of Fiber cable

50

-

363

... More
Splicing / Termination of Fiber Optic Fiber Cable Cores using Fusion splicing with pre-terminated LC pigtails, dressing and proper fixing into splice trays.

96

-

325

... More
SITC of 5 port Industrial Ethernet PoE+ Switch with 2 ports populated with mini GBIC SM SFP ports & 3 nos. 1000MbpsTx ports, inclusive of external DC adaptor/power supply as per OEM requirements read with corrigendum.

12

-

22365

... More
SITC of F/UTP CAT6A Patch Cord 7ft

12

-

187

... More
SITC of DC power Supply 24 VDC

12

-

629

... More
SITC of 10'-15' MS/GI street pole with accessories for mounting of cameras.

12

-

21737

... More
SITC of ruggedized, IP66 rated outdoor pole mountable enclosure for housing power supplies, fiber LIUs, and industrial networking switch, with suitable provisions for DIN rails, cable management.

12

-

13576

... More
3. FIRE DETECTION & ALARM SYSTEM SITC of Microprocessor based Intelligent networkable addressable type fire alarm control panel with display. The panel should be equipped with 1 installed loops, each loop having a capacity of connecting a minimum of 127 addressable detectors and 127 addressable modules or a mix of up to 250 detectors and devices in any combination in any single loop with max. 80% of loading in a single loop,the panel shall be modularly expandable up to minimum 10 loops using loop expansion interface cards, with each loop having a capacity of connecting a minimum of 127 addressable detectors and 127 addressable modules or a mix of up to 250 detectors and devices in any combination in any single loop with max. 80% of loading in a single loop, operating at 240 volts AC power supply, and equipped with automatic battery charger, 24 volts Sealed Maintenance Free (SMF) Lead acid Batteries shall be provided with backup of for 24 hours under Normal working condition & 30 minutes under emergency condition. wiring structure of FACP shall be Class A type (NFPA style 6). The panel shall be supplied with all accessories, control modules and power supply modules in the required quantities as per site requirements for all types of field devices to make the system fully operational. The panel shall be UL 9th or Latest edition Listed and FM approved. Each panel shall be provided with Singlemode fiber optics based hardware interface(s) and software for interconnecting of multiple panels for a peer-to-peer network. All fire alarm panels at site shall be operated and monitored in networked mode and shall be integrated with IBMS system over BacNet/IP protocol; all necessary hardware and software applications and licences for the same shall be provided by the vendor.

15

-

260464

... More
SITC of Microprocessor based Intelligent networkable addressable type fire alarm control panel with display. The panel should be equipped with 2 installed loops, each loop having a capacity of connecting a minimum of 127 addressable detectors and 127 addressable modules or a mix of up to 250 detectors and devices in any combination in any single loop with max. 80% of loading in a single loop,the panel shall be modularly expandable up to minimum 10 loops using loop expansion interface cards, with each loop having a capacity of connecting a minimum of 127 addressable detectors and 127 addressable modules or a mix of up to 250 detectors and devices in any combination in any single loop with max. 80% of loading in a single loop, operating at 240 volts AC power supply, and equipped with automatic battery charger, 24 volts Sealed Maintenance Free (SMF) Lead acid Batteries shall be provided with backup of for 24 hours under Normal working condition & 30 minutes under emergency condition. wiring structure of FACP shall be Class A type (NFPA style 6). The panel shall be supplied with all accessories, control modules and power supply modules in the required quantities as per site requirements for all types of field devices to make the system fully operational. The panel shall be UL 9th or Latest edition Listed and FM approved. Each panel shall be provided with Singlemode fiber optics based hardware interface(s) and software for interconnecting of multiple panels for a peer-to-peer network. All fire alarm panels at site shall be operated and monitored in networked mode and shall be integrated with IBMS system over BacNet/IP protocol; all necessary hardware and software applications and licences for the same shall be provided by the vendor.

4

-

425326

... More
SITC of Microprocessor based Intelligent networkable addressable type fire alarm control panel with display. The panel should be equipped with 3 installed loops, each loop having a capacity of connecting a minimum of 127 addressable detectors and 127 addressable modules or a mix of up to 250 detectors and devices in any combination in any single loop with max. 80% of loading in a single loop,the panel shall be modularly expandable up to minimum 10 loops using loop expansion interface cards, with each loop having a capacity of connecting a minimum of 127 addressable detectors and 127 addressable modules or a mix of up to 250 detectors and devices in any combination in any single loop with max. 80% of loading in a single loop, operating at 240 volts AC power supply, and equipped with automatic battery charger, 24 volts Sealed Maintenance Free (SMF) Lead acid Batteries shall be provided with backup of for 24 hours under Normal working condition & 30 minutes under emergency condition. wiring structure of FACP shall be Class A type (NFPA style 6). The panel shall be supplied with all accessories, control modules and power supply modules in the required quantities as per site requirements for all types of field devices to make the system fully operational. The panel shall be UL 9th or Latest edition Listed and FM approved. Each panel shall be provided with Singlemode fiber optics based hardware interface(s) and software for interconnecting of multiple panels for a peer-to-peer network. All fire alarm panels at site shall be operated and monitored in networked mode and shall be integrated with IBMS system over BacNet/IP protocol; all necessary hardware and software applications and licences for the same shall be provided by the vendor.

2

-

533416

... More
SITC of interface for interconnecting multiple fire alarm system panels over fiber optics media based communication, transceivers or optics must support 100Mbps as per technical specification etc. as required.

21

-

119237

... More
SITC of BaCNet interface for IBMS integration using Ethernet TCP/IP as per technical specification etc. as required.

1

-

126672

... More
SITC of  Fire Command Workstation including Graphical User Interface based software. This shall include any cards, modules, hardware interfaces based on TCP/IP Ethernet communications protocol over fiber optics based media and softwares for providing connectivity and communication between multiple fire alarm system panels. The GUI based main network software shall be capable of graphically representing each node being monitored with floor plans and icons depicting the actual locations of the various systems; and / or sensors’ locations. The GUI software shall be located in control room and shall monitor all the blocks panel connected with each other. Graphic software will interface with fire network via network interface card and shall be able to control and monitor voice evaquation and two way communication system. It shall be inclusive of necessary server grade hardware, min. 42" professional LED display, licenced server operating system, licenced OEM application.

1

-

265904

... More
SITC of A3 sized laser color printer with required accessories and hardware as required.

1

-

21156

... More
SITC of Repeater Panel with 6 inch or 640-characters display. The LCD shall display all events / detectors, devices status of complete systems in the networkas per technical specification etc. as required.

2

-

26552

... More
SITC of loop expansion interface card for providing additional capacity of 1 loop, as per technical specification etc. as required.

1

-

29123

... More
SITC of Addressable Multi-sensor detectors (heat+smoke) for below false ceiling & True ceiling(above false ceiling) with mounting base, LED, Address Switch, inclusive of detector base and complete with all accessories as required. The detector shall be UL/FM Listed/approved. The detector shall include mounting arrangements for direct installation on ceiling/slab as per technical specification etc. as required.

87

-

3379

... More
SITC of Addressable Photoelectric/Smoke Detector with mounting base, LED, Address Switch, inclusive of detector base and complete with all accessories as required. The detector shall be UL/FM Listed/approved. The detector shall include mounting arrangements for direct installation on ceiling/slab as per technical specification etc. as required.

1212

-

3403

... More
SITC Rate of Rise Cum Fixed Temperature detector with mounting base, LED, Address Switch to program the detectors and complete with all accessories as required. The detector shall be UL/FM Listed/approved. The detector shall include mounting arrangements for direct installation on ceiling/slab as per technical specification etc. as required.

101

-

3276

... More
SITC of Beam Detector (Tx-Rx pair) along with reflector plate including mounting base as per technical specification etc. as required.

61

-

34841

... More
SITC of UL/FM Listed/approved 2 way communication Fire Fighter's Telephone Jack inclusive of any required telephone modules or monitor modules or as per OEM

82

-

3802

... More
SITC of UL/FM/ Listed/approved 2 way communication Fire Fighter's Handset

27

-

10462

... More
SITC of Addressable Pull type Manual Call Point with Key reset as per technical specfications with all the necessary mounting accessories as required to complete installation.

135

-

6190

... More
SITC of Addressable Relay module as per technical specification etc. as required.

159

-

5555

... More
SITC of Addressable monitor module as per technical specification etc. as required.

87

-

3503

... More
SITC of Addressable Control module as per technical specification etc. as required.

137

-

5750

... More
SITC of Addressable type isolator modules for isolating shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement as per technical specification etc. as required.

110

-

3083

... More
SITC of Sounder with Strobe device as per NFPA72 edition. The unit shall be configureable simultanuosly for both sounder and strobe fuction. The strobes shall be capable of being synchronized for better evacuation as per technical specification etc. as required.

137

-

12225

... More
Sitc of Directional Sounders with 20 hz to 20 khz operating frequency with multiple 8 distinct sound patterns to indicate corridors, Exit doors and direct Occupants for fast & safe Evacuation as specified in NFPA 72 - 2010 edition.

72

-

15930

... More
SITC of Response Indicator with matching screws complete with GI Junction box, cable lugs at cable end and ferruling and any other hardware as appropriate.

13

-

110

... More
Supplying and drawing 3 x 1.5 sq. mm size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.

18400

-

50

... More
Supply & laying of FRLS type armoured cable of 3 Core x 1.5 sq.mm, Copper (Cu) conductor, Shielded Twisted pair, XLPE insulated wire, confirming to IS standards and as per technical specfications with all the necessary accessories as required to complete laying/installation for Fire alarm System.

3200

-

135

... More
4. ACCESS CONTROL AND TIME ATTENDANCE SYSTEM SITC of ACS client hardware/workstation - industry standard Intel based platform, minimum i7 processor, 2GB RAM, 1TB SATA HDD, dedicated AGP graphics with 1G RAM, DVD, USB ports, min. 19" LED display supporting 1360x768 minimum resolution, rack mountable, licensed Microsoft Operating System Windows 10 or above and requisite user licenses.

1

-

52540

... More
SITC of Centralised Web based Application Software for Configuration, Management & Diagnostics of Access Control Configuration & Time Attendance Management.

1

-

75244

... More
SITC of microcontroller/microprocessor based Door Controller plus Reader for Access Control with all interfaces for computer/server connectivity for card base access control.

12

-

33246

... More
SITC of microcontroller/microprocessor based Controller plus Reader for Time attendance function with all interfaces for computer/server connectivity for biometric base time attendance system.

50

-

39290

... More
Supply, Installation , Testing & Commissioning of Contactless smart Card based on technology MIFARE®, DESFire EV1, MIFARE® Classic.

65

-

314

... More
SITC of Green ABS plastic Emergency Break Glass Units. Current Rating : 12/24VDC, 10A48VDC, 3Amps typical. Various colour options shall be available.

12

-

1028

... More
SITC of Electromagnetic Lock (fail safe type) of 600lbs holding force, dual voltage selectable (12 VDC or 24 VDC), UL listed, Green/Red LED indication for EM Lock Status, with feedback contact. Shall be complete with L/Z/U Brackets as required for mounting on Glass / Wooden frame / Metallic Doors.

12

-

2261

... More
Supply, Installation , Testing & Commissioning and laying of 6 Core X0.5Sqmm Multistrand Copper Cable

700

-

114

... More
Supply, Installation , Testing & Commissioning and laying of 4 Core X0.5Sqmm Multistrand Copper Cable

700

-

91

... More
F/UTP CAT6A COMPONENTS Supply and laying of specified make F/UTP CAT6A cable in prelaid PVC conduits or pipes or raceways or cable trays, but without the cost of conduits or pipes or raceways or cable trays. The cable is to be drawn from individual workstation area/device/IO to the nearest distribution rack or networking rack. It shall be within the scope of integrator/contractor to carry out and submit scanner readings for all IOs meeting the requirements of relevant EIA/TIA standards as per CAT6A cabling requirements. The integrator/contractor shall submit a detail IO maps, labelling and documentation related to terminations.

2300

-

50

... More
SITC of F/UTP CAT6A RJ-45/RJ-45 Patch Cords Solid Conductor of various lengths 3ft

62

-

230

... More
SITC of F/UTP CAT6A RJ-45/RJ-45 Patch Cords Solid Conductor of various lengths: 7ft

62

-

259

... More
SITC with operation training of primevera sofware (Latest verson in consultation of NU) for project management Multi Users atleast for three console under milestone I -Licence upto 2+3 years

1

-

75000

... More
AMC and Onsite support Operation & Comprehensive Maintenance of all the ELV Sytems BoQ items executed under the scope Sub-work I of this NIT During DLP of 24 Months.

1

-

1400000

... More
3rd Year AMC - Operation & Comprehensive Maintenance of all the ELV Sytems BoQ items executed under the scope Sub-work I of this NIT inclusive of all materials and spare parts, which are to be provided by the integrator/bidder free of cost under Defects Liability Period as specified in this NIT, inclusive of all integrator's resources such as trained manpower and operational personnels for all services including routine maintenance, preventive maintenance, breakdown maintenance, software/firmware upgrade, repair and replacement of defective or damaged or burn-out items upon expiry of Defects Liability Period of Two years. 1st Year After Defects Liability Period, i.e., 2 year DLP + additional 1 year

1

-

1000000

... More
4th Year AMC : 2nd Year After Defects Liability Period, i.e., 2 year DLP + additional 2 years

1

-

1300000

... More
5th Year AMC : 3rd Year After Defects Liability Period, i.e., 2 year DLP + additional 3 years

1

-

1700000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.