Ministry Of Road Transport And Highways Tender
... More
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.
AI Insights
Technical
Technical
Financial
Bid Capacity
... View More
The formula for Assessed Available Bid capacity is A*N*3 – B.
Technical Capacity
... View More
The important information given under the technical capacity header which is specifically related to prior work experience is: * The bidder should have experience in similar work, with a minimum value of Rs. 1 crore.
* The bidder should have completed at least one project of similar nature and complexity in the last 5 years.
* The bidder should have a minimum of 5 years of experience in road construction work.
* The bidder should have a minimum of 3 years of experience in the proposed position.
* The bidder should have a minimum of 10 years of experience in civil engineering works.
* Total value of Civil Engineering construction work performed in the last five years.
* Work performed as prime contractor, work performed in the past as a nominated sub-contractor will also be considered provided the sub-contract involved execution of all main items of work described in the bid document, provided further that all other qualification criteria are satisfied (in the same name) on works of a similar nature over the last five years.
* Quantities of work executed as prime contractor, work performed in the past as a nominated sub-contractor will also be considered provided the sub-contract involved execution of all main items of work described in the bid document, provided further that all other qualification criteria are satisfied (in the same name and style) in the last five years.
* Information on Bid Capacity (works for which bids have been submitted and works which are yet to be completed) as on the date of this bid.
* Existing commitments and on-going works, including the description of works, place and state, contract number, and value of contract.
* Percentage of total value of work for various components: Component of Cement: 0.05%, Component of Bitumen: 41.86%
* Total monetary value of construction work performed for each of the last five years.
* Experience in works of a similar nature and size for each of the last five years, and details of works underway or contractually committed.
* Clients who may be contacted for further information on those contracts.
* Achieved in any one year a minimum annual financial turnover (in all classes of civil engineering construction works only) volume of construction work of at least the amount equal to the 50% (fifty percent) estimated cost of works for which bid has been invited.
* 10% of estimated cost (minimum amount of credit facilities required)
* 25% of the contract value of work (minimum amount of investment required during implementation of contract)
* 10% of the bid amount (threshold for sub-contracting of elements of work)
* Rs. 1 crore, Rs. 5 crores, Rs. 30 crores, Rs. 5 crore (threshold for contracts that require proposals for sub-contracting of elements of work)Similar work or eligible projects given in technical capacity experience: * At least one similar work of value not less than the amount indicated in Appendix (usually not less than 25% of the estimated value of the contract)
* Minimum quantities of the following items of work: + Earthwork for maintenance of Earthen shoulder: 7840.00 sqm (combined quantities) + Bituminous Work (DGBM + BC): 2081.90 cum
* The contractor or his identified sub-contractor should possess required valid electrical license for executing the building electrification works and should have executed similar electrical works for a minimum amount as indicated in Appendix in any one year.
* The contractor or his identified sub-contractor should possess required valid license for executing the water supply/sanitary engineering works and should have executed similar water supply/sanitary engineering works for a minimum amount as indicated in Appendix in any one year. Note: The amount indicated in Appendix is not specified, but it is mentioned that it is usually not less than 25% of the estimated value of the contract.
Costs
EMD
₹ 16,89,000Document Cost
₹ 10,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MoRTH_855340_1Bid Award Id
ViewTender No
RE-NIT NO. 01/2025-26Tender Authority
Ministry Of Road Transport And Highways ViewPurchaser Address
-
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.
9693.63
705
6836917.24
... More
Road Stud Supplying of Solar Raised Pavement Markers made of polycarbonate molded body. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the engineer.
8523
294
2506614.3
... More
Maintenance of Earthen Shoulder (filling with fresh soil) Making up loss of material/ irregularities on shoulder to the design level by adding fresh approved soil and compacting it with appropriate equipment.
15680
88
1381408
... More
Retro-Reflectorised Traffic Signs
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.
80x60 cm rectangular
10
8011
80113.2
... More
Retro-Reflectorised Traffic Signs
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.
60 cm circular
20
5819
116392.4
... More
Retro-Reflectorised Traffic Signs
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 60 cm x 45 cm rectangular
10
5675
56750.2
... More
Retro-Reflectorised Traffic Signs
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.
60 cm equilateral triangle
15
4406
66100.8
... More
Direction and Place Identification Signs upto 0.9 sqm size Board.
Providing and erecting direction and place identification retro- reflectorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4 mm with area exceeding 0.9 sqm fixed over back support frame of min 40 x 40 x 5 mm Angle mounted on two nos. of mild steel circular pipe 65 NB, 3.2mm thickness and 4.5m meter total height firmly fixed to the ground by means of properly designed foundation with M 25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing
6.48
14531
94164.51
... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc
5th kilometre stone (precast)
2
4431
8863.72
... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc
Ordinary kilometer stone (precast)
6
2585
15514.8
... More
Kilometre Stone Reinforced cement concrete M15 grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc
Hectometer stone (precast)
38
741
28181.56
... More
Painting on concrete surface
Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm.
17850
130
2336565
... More
Printing New Letter and Figures of any Shade Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade
English and Roman
4995
-
3996
... More
Brick masonry work in 1:3 in substructure complete excluding pointing and plastering, as per drawing and Technical Specifications
34.5
6660
229780.7
... More
Plastering with cement mortar (1:3) on brick work in substructure as per technical specifications
250
154
38597.5
... More
Labour cess @1% on total amount from item s.no. 01 to 18
70546322.68
-
705463.23
... More
Segniorage fee amount
3145749.1
-
314574.91
... More
G.S.T. @ 18% on total amount from item s.no. 01 to 20
71566360.82
-
12881944.95
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements