Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Provn Of Igloo Type Dbs At Af Stn Purnea in Purnia, Bihar, with an estimated contract value of Rs. 21,21,05,146. The bid opening date for this tender is 04-06-2019 and the last date for bid submission is 19-03-2020. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Opening Date4 Jun 2019
Closing Date19 Mar 2020
Tender Amount₹ 21,21,05,146 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT. BIDDERS ARE ADVISED TO READ APPENDIX-A TO NIT CAREFULLY BEFORE QUOTING THE BID
Bill of Quantities /Schedule A to be quoted Bidder. Bidders are advised to read Tender carefully before quoting the BOQ
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SCHEDULE "A" PART-XII (DEMOLITION/DISMANTLING) Details of prepriced Schedule is given in tender documents.

1

-

1122730.0999999999

... More
S&F MCB TPN 32Amps (C-Curve), breaking capacity 10KA, 440V with cable connection and copper lugs all as specified and directed.

6

-

-

... More
M&L Reducer socket, 250mmx200mm (internally), fabricated from MS ERW casing pipe of 250mm bore by arc welding including necessary anti rusting black bituminous painting complete all as specified and directed.

1

-

-

... More
Construction of IGLOO building with traverse and traverse wall VIFT including covered shed for loading bay, road and drain infront of platform complete all as specified and as shown on drawings

2

-

-

... More
AIR CONDITIONING . Supply, Installation, Testing and Commissioning of Chilled water Central Air-conditioning system of capacity not less than 60 TR (2x30 TR working and 1X30 TR standby ) including following items and other items as required for satisfactory performance of the plant complete in all respect for DBs all as specified in respective drawings to achieve the inside design conditions as per ANNEXURE ‘A’ and details as per ANNEXURE 'A-1' enclosed here-in-before :- Note 1 :- (a) Contractor / bidder should submit complete design for the Central AC plant comprising of heat load calculations, working drawings of complete AC plant supported with design/calculations of each component duly vetted by IIT/NIT within two months of the date of commencement of work through GE for the approval of Accepting Officer before execution of the work. (b) Contractor/bidder will be responsible for performance guarantee of complete AC plant to achieve the inside design conditions round the clock throughout the year with overall COP of the system not less than 3. Note 2 :- Rates quoted by the contractor shall be complete finished work including cost of all labour, material, scaffolding, finishing as required with tools, plants, cartage, lift, taxes, tollage, octroi, royalties etc. All works shall be executed as per drawings and instructions of Site in-charge and shall include the supply and installation at site of all the equipment, ancillary materials as specified and all such items what-so-ever which may be required to fulfill the intent and purpose as laid down in the drawings. All materials shall be as per ISI specification and with IS certification marked wherever applicable. The material shall be duly approved by Site in-charge before incorporation in the actual work.

1

-

-

... More
SCHEDULE "A" PART-XIII (WATER TANK OF CAPACITY 14400 LTR WITH 4 MTR STAGING) Details of prepriced Schedule is given in tender documents.

1

-

336014.53

... More
INTERNAL ELECTRIFICATION. M&L for flame proof sub main wiring with two run of single core pvc insulated unsheathed FRLSH copper conductor 1100 volt grade multistranded of size 2.5 sqmm drawn through and including stove enamelled ERW steel conduit on surface and conduit accessories of 20 mm dia heavy duty for eight light points or six light points controlled by one switch/MCB including one run of 2.5 sqmm copper wire for earth continuity wire and connected of common earth dolly complete all as specified and directed. Note:- 1. One run of conduit and three run of 2.5 sq mm copper conductor shall be measured as one unit.

-

-

-

... More
SCHEDULE "A" PART-VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.

1

-

1362039.2

... More
M & L Earthing complete with using copper plate electrode 300 X 300 X 3.00 mm thick, buried directly in ground (earth pit not less than 2.25m depth below GL ) with top edge of the plate not less than 1.5m below normal GL, connected to 20 x3 mm copper strip as earthing lead by means of nuts, bolts, check nuts, washers protected by 25mm GI pipe medium grade etc connected to test point all as specified and testing point or main controlling switch as directed incl funnel with watering pipe 20 mm bore light grade GI pipe, wire mesh, charcoal and common salt, concrete earth pit PCC (1 :3:6 ) type C1, pre-cast RCC 1:2:4 type B-0 cover slab reinforced with 6mm dia mild steel round bar @ 10cm c/c both ways and suitable handle of 10mm dia round bar with 40x40x6mm agnle iron frame duly painted with two coats of synthetic enamel paint over a coat of zinc chrome primer including necessary excavation in soft / loose soil and disposal of soil to a distance not exc 50 mtr and necessary testing on completion, complete all as shown in electrical plate No. 3 of MES schedule Part I testing and all as directed.

10

-

-

... More
M&L for flame proof point wiring with 1.5 Sqmm(nominal area) FR-LSH PVC insulated and unsheathed 1100V grade multistranded copper conductor single core cable drawn through and including 20mm dia stove enameled ERW steel conduit screwed medium grade on surface complete with all fittings such as elbows, bends, connectors, saddles, clamps etc suitable for one light/fan point controlled by one switch including unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm as earth continuity conductor connected to common earth dolly including testing on completion all as specified and directed. Note: One run of conduit and three run of 1.5Sqmm copper cable shall be measured as one unit.

4

-

-

... More
M&L for pulling out and lowering in of submersible pump set from bore well made of 2Nos RCC pillars of size 45cmx45cm,5m height from GL and MS Channel of approx 2.5m length of size suitable to carry load of approx 3 Ton including provision of MS flexible rope and pulley complete all as directed by Engr-in-Charge.

1

-

-

... More
Construction of DG Shed complete all as specified and as shown on drawings.

1

-

-

... More
Testing of water for chemical, bacteriological and potability test form Govt/NABL Lab and submission of testing report.

1

-

-

... More
Supply, installation, commissioning and testing of Indian Iron removal plant factory assembled floor mounted, of capacity 5000 Gallon/hrs, constructed Frontal pipe with mild steel pipe of size 150 mm, cylinder made with mild steel as per IS, hydraulically tested for pressure 10 kg/Sqm, designed and constructed for minimum shell thickness 8 mm and dished thickness 10 mm cylinderical type of suitable size diameter including various filter media (Required quaintly 5000 Gln/hrs) and complete suitable for treatment of raw water to limit content after treatment face piping, fitting, valve etc., PCC foundation required at site and as recommended by manufacturer, all as specified and as directed comprising of following:- (a) Max working pressure 3.5 Kg/sq cm and min working pressure 2.0 Kg/sq cm including gauge 0 to 06 Kg/sqcm (b) PH – 6.5 to 8.5 (c) Turbidity (NTU) – 5 to 10 (d) Iron, mg/L- 0.3 to 1.0

1

-

-

... More
Electro logging by means of electric logger of the complete tube well of 500 mm bore and submission of report along with its interpretation indicating exact location of filters alongwith complete casing assembly chart in the bore hole.

1

-

-

... More
S&F Flame proof sheet metal enclosure for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar, neutral link, dinrail suitable for mounting MCB's 240 volts double door type complete all as specified and directed. Note : MCB's are measured and paid in separate items.

2

-

-

... More
Supply, install, commissioning and testing electrically operated Chlorine dosing pump mounted on calibrated FRP dosing tank of 100 Ltr cap with lid, single phase electric motor and agitator with shaft & blade in SS316 (FRP/Epoxy coated)/Plastic complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
S&F holding clamp fabricated from mild steel plate of 10mm thick of size 115cmx20cm in two halves having four Nos (two at each end) 24mmx150mm GI bolts, nuts, washers suitable for clamping and holding 250mm bore casing pipe duly painted with two coats of black bituminous paint and grouted in PCC (1:2:4) type B 1 using 20 mm graded stone aggregate in block all as specified and directed by Engr-in-Charge.

1

-

-

... More
S&F Elastomer electric insulating mat (Non skid type) class ‘B’ of size 1mx2mx2.50mm thick suitable for 11KV rating installations all as per IS: 15652-2006. Make: JB, Safe-Volt, Jyoti

6

-

-

... More
DEMOLITION/DISMANTLING. Dismantling barbed wire from fencing post and stacking properly for measurement.

25

-

-

... More
M&L for flame proof point wiring with 1.5 Sqmm(nominal area) FR-LSH PVC insulated and unsheathed 1100V grade multistranded copper conductor single core cable drawn through and including 20mm dia stove enameled ERW steel conduit screwed medium grade on surface complete with all fittings such as elbows, bends, connectors, saddles, clamps etc suitable for one light/fan point controlled by one switch including unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm as earth continuity conductor connected to common earth dolly including testing on completion all as specified and directed. Note: One run of conduit and three run of 1.5Sqmm copper cable shall be measured as one unit.

4

-

-

... More
Development of tube well by compressed air with compressor of minimum capacity of 1100/350 CFM/PSI.

24

-

-

... More
Supply & Installation Pumping set, centrifugal, electric driven of 2HP complete including starter and PCC foundation and connection complete all as specified and as directed.

1

-

-

... More
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents

1

-

6686706

... More
Supply and fixing HT SMU of 11 KV LBSF panel outdoor complete with 630 Amps load break swtich 200 Amp D.O set , earth switch, PCC etc complete all as specified and directed.

2

-

-

... More
S&F LED T-8 Retrofit tube light fitting 4 ft 20 watt, 230 volt energy efficient epoxy powder coated CRCA sheet housing with channel, connector block, etc. complete with all accessories internally prewired and including connected with twin core twisted flexible wire copper conductor cable with suitable size complete all as specified and directed.

45

-

-

... More
Supply, installation, commissioning and testing floor mounted outdoor cubical type LT Panel board (CPRI tested) suitable to accommodate under mentioned accessories fabricated out of not less than 3.0 mm thick CRCA sheet and angle iron 50X50X6mm frame, factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskits aluminium busbar fixed on porcelain insulator with internal wiring with suitable size of aluminium strip to be used for incoming and outgoing connection of all Switches/MCCBs and bus bars, bus bar shall be insulated with colour codes sleeves/tapes and to be connected with aluminium lux, powder coated with grey paint of approved shade on panel sheet duly 9 tank surface treated including necessary PCC(1:3:6) type C2 as in foundation all as directed comprising of the following. Incoming (i) 400 Amp MCCB 4 pole 50 KA- 01 No (ii) Digital type voltmeter 0-500Volts with selector switch -1 Set (iii) Digital type ampere meter 0-200 Amps with CTs & selector switch -1 Set (iv) Indicator lamp- R-Y-B (set of three) (v) Alluminium bus bar rating 500 Amp 4 way. Outgoing (i) 250 Amp MCCB 4 pole 35 KA- 01 No (ii) 40 Amp MCCB 4 pole 16 KA - 01 No (iii) 16Amp MCCB 4 pole 16 KA - 04 Nos (iv) 20 Amp MCB SPN 16 KA - 02 Nos (v) S&F time switch 415 volt TPN 20 Amp - 01 No Note :- (i) All MCCBs 63Amp and above rating shall be of adjustable TM setting for overload & short circuit.. (ii) Cost of cable glands, lugs/thimble and feeder identification marking shall be deemed to be included in the quoted lump sum.

1

-

-

... More
M&L for LED street light luminaries of 25 watt white light pressure die cast housing with epoxy powder coated, heat resistant toughened glass with individual LED lenses, electrically connecting up with three core 2.5 sqmm PVC insulated stranded copper wire including suitable GI bracket and fixing arrangement complete all as specified. Make: C&S Electric cat No. LTESS10X2.5HPLED/LS or equivalent from make list as specified in PS.

12

-

-

... More
S&F Exhaust fan 300 mm sweep 240 volt AC and including connected with twin core twisted flexible wire copper conductor cable with suitable size complete with louver all as specified and directed. Make Havells model No. Ventil Air-DB or equivalent from make list as specified in PS.

2

-

-

... More
S&F LED Flame proof flood light fitting 80W in cast aluminium alloy LM6 construction with integral reflector and mounting arrangement on wall/pillars complete all as specified and directed.

52

-

-

... More
All as per item Srl Item No 16.28 here-in-before but of 200mm bore.

70

-

-

... More
S&F 15 mm bore angle stop cock brass CP high pressure with capstan head, long shank screwed down complete all as specified and directed.

6

-

-

... More
SCHEDULE "A" PART-XIV (RCC SEMI UNDER GROUND SUMP OF CAPACITY 60,000 LTR) Details of prepriced Schedule is given in tender documents.

1

-

631736.1350000001

... More
M&L for Earthing complete with galvanized steel earth plate electrode 60 x60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to GI earth lead 32 x 6 mm dia by means of bolts nuts, check nut and washers of GI and GI tubing 40 mm bore medium grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C 1, pre cast RCC (1:2:4) type B1 cover slab 450 x 450 x 50 mm with one handle for lifting made out of 8 mm dia MS bar, wire mash, 20 mm bore GI tubing light grade for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed Electrical plate no 3 of SSR Part-I.

48

-

-

... More
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.

1

-

112547.50000000003

... More
S&F Flame proof sheet metal enclosure for MCB TPN Double door DB 4-way,440V, with 200Amp rated bus bar, neutral link, din rail suitable for mounting MCBs complete all as specified and as directed. (Note: MCBs shall be measured and paid under separate item).

2

-

-

... More
Supply, installation, commissioning and testing floor mounted outdoor cubical type LT Panel board (CPRI tested) suitable to accommodate under mentioned accessories fabricated out of not less than 3.0 mm thick CRCA sheet and angle iron 50X50X6mm frame, factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskits aluminium busbar fixed on porcelain insulator with internal wiring with suitable size of aluminium strip to be used for incoming and outgoing connection of all Switches/MCCBs and bus bars, bus bar shall be insulated with colour codes sleeves/tapes and to be connected with aluminium lux, powder coated with grey paint of approved shade on panel sheet duly 9 tank surface treated including necessary PCC(1:3:6) type C2 as in foundation all as directed comprising of the following. Incoming (i) MCCB 400 Amp, 415 volt, 50 Hz, 4 pole, 50 KA-01 Nos (ii) Digital type voltmeter 0-500Volts with selector switch -1 Set (iii) Digital type ampere meter 0-500 Amps with CTs & selector switch -1 Set (iv) Indicator lamp- R-Y-B (set of three) (v) Alluminium bus bar rating 500amp 4 way. Outgoing (i) 320 Amp MCCB 4 pole 50 KA- 01 No (ii) 250 Amp MCCB 4 pole 35 KA- 01 No (iii) 63 Amp MCCB 3 pole 25 KA- 02 Nos (iv) 40Amp MCCB 4 pole 16 KA - 01 No (v) Dial type Street light timer switch 415V TPN 20Amp complete with relay, contactors and toggle switch for auto/manual operation – 02Nos. Note :- (i) All MCCBs 63Amp and above rating shall be of adjustable TM setting for overload & short circuit.. (ii) Cost of cable glands, lugs/thimble and feeder identification marking shall be deemed to be included in the quoted lump sum.

1

-

-

... More
PRIME COST SUM. The prime cost is to used as directed by the Accepting Officer vide condition 1(v) and 5 of IAFW-2249. (a) Provide a prime cost of Rs. 6,00,000.00 for Provision four sets of Steel Roller Treadway (Each Set consists of two Nos Steel Roller) for 02 Igloo Buildings as approved by GE. (b) The contractor is to quote the amount in the money column i.e. in Col 6 adding his overhead and profit. The amount shall be adjusted proportionately to the sum actually expended against Prime Cost Sum. Notes :- (i) Item(s) covered under Prime Cost Sum shall be ordered as per condition 5 of IAFW-2249. (ii) Contractor shall quote amount adding over the amount of prime cost sum to cover his overhead and profit against Srl Item No 16.75(a).

1

-

-

... More
INTERNAL WATER SUPPLY. S&F 15 mm bore brass bib tap cast copper CP high pressure with long shank and cup, capstan head, screwed down complete all as specified and directed.

3

-

-

... More
RCC SEMI UNDER GROUND SUMP OF CAPACITY 60,000 LTR. S&F of 250mm x 10mm PVC water stop for construction joint in RCC work in different location during construction.

94.84

-

-

... More
S&F Ceiling fan 1400 mm sweep 240 volt AC white colour 5 star rated and including connected with twin core twisted flexible wire copper conductor cable with suitable size complete all as specified and directed. Make Havells model No.SS 390 or equivalent from make list as specified in PS.

2

-

-

... More
EOT CRANE. Design, supply and installation of flame proof EOT crane duty class M2, double girder type having span of 9.5 m, long travel 36 m, clear hook height 3.0 m and weight lifting capacity of 5.0 Ton considering following conditions complete all as specified and directed:- (i) Internal dimension of Bldg is 36m X 19m X 5.2m with partition wall at middle. (ii) Clear hook height available from FFL is 3.0m (iii) The operation and micro speed of crane should be as following:- (a) Main Hoist:- 3-4m/min (d) Micro in cross travel - 0.5 m/min (b) Micro in main Hoist - 0.3-0.4m/min. (e) Long travel - 10-15 m/min (c) Cross travel - 5 m/min (f) Micro in long travel- 1m/min (iv) EOT crane fitted should be fire/flame proof and comply with the safety specification given in the STEC pamphlet No 7. (v) EOT crane fitted should be comply with the saftey specification such as limit swiches, alarm, guards, isolating switches, emergency stop button and interlocking, power and control cabling complete etc confirming to IS-807, IS-3177, IS-3938 specifications. (vi) Design, Supply, Installation, Testing and Commissioning of Crane shall be undertaken through Manufacturers/ Specialist Firms. (vii) Design of crane and proof checking of design from any of Government Chartered Engineers within 2 months from the date of acceptance of tender. (viii) Crane fabricator to verify the exact internal diamensions of the building physically before starting fabrication of the Crane. (ix) VVVF Drive to be provided.

4

-

-

... More
SCHEDULE "A" PART-VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.

1

-

45356.020000000004

... More
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.

1

-

7441.299999999999

... More
S&F submersible pump electric driven 415 V, TP suitable for 200/250 mm dia bore well (casing pipe size 200/250mm) and installed complete of capacity 15HP Head 50 mtr including of 40 mtr long submersible cable and starter complete all as specified and directed.

1

-

-

... More
Yield testing of bore well by continuous pumping for 16 hrs to determine the safe pumping yield by V-notch.

1

-

-

... More
S&F MCB TPN 63Amps (C-Curve), breaking capacity 10KA, 440V with cable connection and copper lugs all as specified and directed.

2

-

-

... More
Supplying, assembling, including jointing, lowering and fixing in position 200 mm bore (Nominal size), 7mm thick Low Carbon Galvanised Steel (LCG) strainer with continuous slot screen (V-Wire Strainer) of 1.00mm slot width to give an open area of 30% complete all as per IS-8110 : 2000 assembled and lowered as per electro logging result and location approved by the GE including cutting welding as required complete all as specified. (Make: Jhonson/Jindal/Tata/Vansh Tube)

20

-

-

... More
SCHEDULE "A" PART-V (ROAD/PATH/CULVERT) Details of prepriced Schedule is given in tender documents.

1

-

6408269.593000001

... More
SCHEDULE "A" PART -XVI (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.

-

-

-

... More
SCHEDULE "A" PART-XV (STATIC WATER TANK OF CAPACITY 110 KL) Details of prepriced Schedule is given in tender documents.

1

-

672740.28

... More
Construction of AHU Building complete all as specified and as shown on drawings.

1

-

-

... More
Development of tube well by means of submersible pump (of capacity not less than 25% of rated pump capacity) as required to make the well sand free upto 20 PPM in 20 min complete all as specified.

24

-

-

... More
SCHEDULE "A" PART-XVII (SCHEDULE OF CREDIT) Note :- Amount of Rs. 1623420.00 indicated in Tender as Schedule of Credit shall be deducted from the total quoted amount of BOQ.

-

-

-

... More
SCHEDULE "A" PART-X (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents

1

-

415201.8

... More
Widening of trial bore by drilling with direct / reverse rotary system upto 500 mm dia bore at any depth including all works pertaining to boring complete in all respects and all specified in alluvium spoil/soft strata incl hard stone/boulder etc. upto 130 mtr depth from ground level. Note :- Reaming/widening of trial bore to any depth beyond 130mtr if required at site shall be carried out with prior approval of Accepting Officer and shall be paid under this Item.

130

-

-

... More
S&F MCB SPN 6 to 32 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and directed.

5

-

-

... More
S&F Valve, reflax with bypass arrangement 50mm dia complete all as specified and as directed.

2

-

-

... More
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.

1

-

498100.99999999994

... More
Construction of brick masonry valve pit of size 90 cm x 90 cm x 90 cm (internal dimensions) with one brick thick wall in cement mortar 1:4 on 100 mm thick P.C.C 1:4:8 type D2 (using 40mm graded broken stone aggregate ) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in bedding and coping and 10mm thick cement plaster in CM (1:4) internally and externally up to 15cm below ground level and providing 25 x25 x6 mm angle iron frame all around the fixed point by means of 4 Nos holdfast 150 mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20 mm graded crushed stoned aggregate) of size 250x 200 x 150 mm including provision of hinges welded with angle iron frame and MS sheet cover 3mm thick, MS handle of suitable size welded with MS cover and suitable locking arrangement including 65 mm dia Godrej pad lock and applying two coats of synthetic enamel paint over a coats of red oxide primer including necessary excavation and earth work in soft/ loose soil complete all as specified and as directed.

2

-

-

... More
Supply and Fixing Air release valve cast iron 50 mm with 2 air outlets and fix up in GI pipe with necessary fitment water supply mains complete all as specified and directed

1

-

-

... More
Design, supply and installation of flame proof EOT crane duty class M2, double girder type having span of 7 m, long travel 19 m, clear hook height 4.20 m and weight lifting capacity of 5.0 Ton considering following conditions complete all as specified and directed:- (i) Clear hook height available above ground level of approach road should be minimum 4.20 m (ii) The operation and micro speed of crane should be as following:- (a) Main Hoist:- 3-4m/min (d) Micro in cross travel - 0.5 m/min (b) Micro in main Hoist - 0.3-0.4m/min. (e) Long travel - 10-15 m/min (c) Cross travel - 5 m/min (f) Micro in long travel- 1m/min (iii) EOT crane fitted should be fire/flame proof and comply with the safety specification given in the STEC pamphlet No 7. (iv) EOT crane fitted should be comply with the saftey specification such as limit swiches, alarm, guards, isolating switches, emergency stop button and interlocking, power and control cabling complete etc confirming to IS-807, IS-3177, IS-3938 specifications. (v) Design, Supply, Installation, Testing and Commissioning of Crane shall be undertaken through Manufacturers/ Specialist Firms. (vi) Design of crane and proof checking of design from any of Government Chartered Engineers within 2 months from the date of acceptance of tender. (vii) Crane fabricator to verify the exact diamensions of the building physically before starting fabrication of the Crane. (ix) VVVF Drive to be provided.

2

-

-

... More
Supply, installation, testing and commissioning indoor type APFC bank panel MDXL/LTXL with thyrister control module with aluminium heat sink with semi-conductor fuses, smooth switching On and Off automatically at + 10 volts, compartmental design dust and vermin proof suitable for 3 phase, 4 wire 440 volt, made out of 2mm thick CRCA sheet with built upon rigid frame work, cubical type type, duly powder coated RAL 7035, capacity 75 KVAR (1x25+1x20+2x10+1x5+2x2.5) KVAR capacitor bank having following accessories including control wiring with HR FR / FRLS copper wire complete all as specified and directed as follows :- (i) Compact modular bolted design, removable side and back panels with bottom cable entry. (ii) Capacitor installed in removable assemblies for ease of operation and maintenance. (iii) Incoming of APFC panel of MCCB TPN 100 Amps, 25 KA breaking capacity with high electrolytic grade Aluminium bus bar of suitable rating. (iv) MDXL/LTXL capacitors of 75 KVAR (1x25+1x20+2x10+1x5+2x2.5) with capacitor duty thyrister control module & branch protection MCCBs of suitable rating with semi-conductor fuses to each capacitors . ( each capacitor bank equipped with discharge resister) & 7% detuned harmonics filter reactor. (v) High performance microprocessor based 3 phase APFC relay 7 stage with Auto/Manual Option. (vi) 3 phase power analyzer with inbuilt, Amp meter, volt meter and PF meter. (vii) Induced air system provided with axial flow fan/ centrifugal fan. (viii) Sensing CT of suitable rating.

1

-

-

... More
EXTERNAL ELECTRIC SUPPLY. Supply, installation, commissioning and testing of 250 KVA, Silent Diesel Engine driven generating set outdoor type 415 Volts, 3 phase 4 wire, engine as per IS : 10002 and alternator as per IS : 13364(Pt-2) complete with relay panel for automatic starting on mains failure, control panel having meters, sound proof canopy and concrete foundation complete all as specified and directed comprising of following:- A. a) Fly wheel to suit flexible coupling. b) Flexile coupling with guards. c) Dry type air cleaners with filters. d) Lubricating oil filter, fuel filter, fuel pre filter. e) Anti-vibration pads-quantity and type as recommended by manufacturer. f) Fuel injection system with injector pump, nozzles, governor(electronic) of suitable capacity. g) Electric start equipment. h) Lead acid storage maintenance free battery 2x12V DC of suitable rating with charging alternator, ammeter, as recommended by manufacturers make: As per OEM standard along with copper battery lead and connector. i) Battery rack made out of MS angle iron 40mmX40mmX5mm and 150mm height. j) Standard safety device. k) Daily service fuel tank of suitable capacity for running 12 hrs non-stop on Full Load with mechanical level indicator, detachable strainer, drain cock, fuel outlet, air vent and locking arrangement etc, including fuel pipe connections. l) Exhaust silencer(Residential silencer) with exhaust piping of suitable size brought out side on top of size 76.5 mm dia and complete length of silencer and exhaust piping continuously wrapped with 12 mm dia asbestos rope and suitable anti vibration arrangement around pipe passing through wall. m) LCD display type control panel as per manufacturer's instructions indicating KWH, KVA, PF, Volts, Amps, Hz, RPM, Hour, Oil pressure, Oil temprature, coolent temprature, fuel level, battery charging ammeter, battery charging lamp and incator lamp (RYB), panel duly prewired and displaying protection and safetys as under:- aa) Protection:- short circuit, overload, over speed, earth fault as standard and reverse power as optional. ab) Safeties:- Auto shut down, visual & audio alarm for low lub oil pressure, high coolant temperature, low fuel level, canopy temperature & radiator water level.

1

-

-

... More
Construction of Pump House Building complete all as specified and as shown on drawings.

1

-

-

... More
Supplying, assembling, jointing, screwed, welded, lowering and fixing in position of ERW MS casing pipe 250 mm Bore (Nominal size) of 8 mm thickness, plain end, blank jointed with collar through electric resistance of high frequency induction welding for jointing of pipe including necessary fittings and providing a anti rusting coat of black bituminous paint (for drinking purpose) externally complete as per IS-4270 : 2001 upto required depth below ground level in all strata (according to location chart) cut into different lengths ISI marked and all as specified and directed by Engr-in-Charge.

40

-

-

... More
S & F LED 9 W lamp with polycarbonate body and aluminum heat sink cool white illumination.

2

-

-

... More
S&F of well cap suitable for fixing on top of 200 mm dia casing pipe made out of 6mm thick mild steel plate with locking arrangement including spot welding with casing pipe having opening for column pipe of 100mm bore and submersible cable including necessary painting with two coat of black bituminous paints all as directed by Engr-in-Charge.

1

-

-

... More
Supply only rubber hand gloves for 11 KV line on 15 KV complete all directed.

1

-

-

... More
Supply and installation of water cooler electric driven (single phase), Having approx storage capacity of 40 Ltrs and nominal cooling capacity of 40 ltrs per hours.

1

-

-

... More
LIGHTENING PROTECTION. Supply and fixing H Beam pole 150 mm x 150mm 16 mtr height (weight 37 Kg per RM) complete all as specvified and as directed.

18

-

-

... More
M&L for Earthing complete with galvanised steel earth plate electrode of size 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth lead wire 4.0 mm dia by means of nuts, bolts, check nuts, washers of galvanised iron all as shown in electrical plate No 3 all as specified and indicated complete with funnel, charcole, dust, salt etc and GI protection pipe, medium grade 15 mm bore and GI watering pipe 20 mm bore medium grade, Concrete earth pit in PCC(1:3:6) type C-1, 40mm thick pre cast RCC 1:2:4 type B-0 cover slab reinforced with 6mm dia mild steel round bar @ 10cm centre to centre both way and suitable handle of 10mm dia round bar, including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc 50m and necessary testing complete all as specified and as directed.

14

-

-

... More
Trial bore holes 150 mm dia for exceeding 100mtr but not exceeding 130 mtr in depth from ground level in any type of strata for bore well if the same is found fit otherwise to fill up the same hole as directed by Engineer-in-Charge complete including submitting the strata details both graphically recommended as well as strata results as per IS- 2800 : 2000. Note :- Boring to any depth beyond 130mtr if required at site shall be carried out with prior approval of Accepting Officer and shall be paid under this item.

30

-

-

... More
Supply & fixing bail plug made out of 200mm bore ERW MS casing pipe of 8mm wall thickness,3.0m long including 20mm dia,50cm long D-block welded at the bottom complete all as directed by Engr-in-Charge.

1

-

-

... More
SCHEDULE "A" Part - I (BUILDING / STRUCTURE) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.F signifies this fact only.

-

-

-

... More
Serial Item No. 16.54 (Contd....) (B) Alternator 250 KVA brushless type at 0.8 power factor, self regulated, self excited, screen protected 3 phase with neutral 415 volts 50 HZ, 1500 RPM, as per IS:13364/IS-4722 complete with automatic voltage regulator, having voltage regulation +/-1%, SPDP enclosure including making cable connections, insulation class-H and alternator control panel as supplied by manufacturer. C) Base frame sturdy, MS fabricated, channel iron base frame for mounting the engine & alternator with anti vibration pads. (D) Acoustics enclosure of suitable size to accommodate DG set 250 KVA, modular construction, fabricated out of 3 mm thick, cold annealed CRCA sheet duly epoxy painted doors to be provided with high quality EDPN gasket, duly epoxy painted. The canopy to be equipped with heavy duty fans of reputed manufacturer for air circulation and cooling the canopy. Rock wool of requisite density per Kg/m3 to be used for insulation. Enclosure to be provided with one light point controlled with one switch for internal lighting. Noise level at one meter to be 75 decibels @ one meter in line as per CPCB norms. (E) Repair tools to be supplied as under:- (i) Ring spanner set of 10- 01 set. (ii) Screw driver 6",9", 12", 14" - 01 No Each. (iii) Adjustable spanner 12" - 01 No. (iv) Double end spanner set of 10 - 01 No. (v) Cutting pliers insulated and nose plier 10" & 12" - 01 No. (vi) Techo meter - 01 No. (vii) Tool kit box - 01 No. (F) Maint spares to be supplied as under :- (i) All type of filters - 02 Each. (ii) V-Belt - 01 Set NOTE:- (i) The engine of DG set suitably conditioned to suit the climatic condition, so as to give desire outputs including and testing up to 10% over load. (ii) Foundation of the DG set (PCC/RCC) will be provided by the contractor and will be made as per the manufacturer instruction. Cost of foundation is deemed to be included in the rate of this item. (iii) The items required for testing of DG set e.g. fuel, tripod, tools, water tank etc and panel as below shall be provided by the contractor and the rate of which is deemed to be included in the rate of item. (iv) Testing of DG set will be carried out as specified.

-

-

-

... More
SCHEDULE "A" PART-II (SITE CLEARANCE, EARTH WORK AND EXCAVATION ) Details of prepriced Schedule is given in tender documents

1

-

4255937.65

... More
Construction of AC Plant with AHU Building complete all as specified and as shown on drawings.

1

-

-

... More
M&L for strata sample box of second class hard wood of size 40 cm X 30 cm x 20 cm complete all as directed by Engineer-in-Charge.

1

-

-

... More
S&F Octagonal Pole 8mtr long made of hot dipped GI tube 3mm thick having bottom dia 135mm, top dia 70mm, base flange size 225x225x16mm,single arm bracket 1000mm, fixing nut & bolts of high tensile MS rod, template, TPN connector for loopin & out of main cable, MCB SP,6A rating, cable copper conductor 3-core 1.5Sqmm from junction box to light fitting complete including necessary PCC foundation for mounting of pole as per manufacturer’s specifications. Make :Wipro/ Bajaj/CG or equivalent.

73

-

-

... More
Supply and fix GI column pipe medium grade IS-1239 marked 80 mm bore x 3 mtr long both end flanged joints duly screwed and welded with pipe suspended in deep bore well with groove/cut for submersible cable screwed and welded on both ends including provn of 3mm thick rubber gasket packing and GI nut bolt with washers.

30

-

-

... More
S&F LED street light luminaire 60W with integral driver, surge protection upto 5KV, Pf not less than 0.95,system efficiency not less than 85%, suitable to work on 120-270V supply duly housed in pressure die cast aluminium housing powder coated, toughened glass, IP-66 Class-I.

81

-

-

... More
Supply and Fixing Air release valve cast iron 150 mm with 2 air outlets and fix up in GI pipe with necessary fitment water supply mains complete all as specified and directed

1

-

-

... More
Construction of Sub Station Building complete all as specified and as shown on drawings.

1

-

-

... More
S&F Elastomer electric insulating mat (Non skid type) class ‘A’ of size 1mx2mx2.0mm thick suitable for 440V rating installations all as per IS: 15652-2006. Make: JB, Safe-Volt, Jyoti

6

-

-

... More
S&F Exhaust fan 450 mm sweep 240 volt AC and including connected with twin core twisted flexible wire copper conductor cable with suitable size complete all as specified and directed. Make Havells model No. Ventil Air-DB or equivalent from make list as specified in PS.

3

-

-

... More
SEWAGE DISPOSAL. Construction of Septic Tank for 10 users complete all as shown on drawings and as specified.

1

-

-

... More
SCHEDULE "A" PART-XI (SECURITY WALL/FENCING/GATE) Details of prepriced Schedule is given in tender documents.

1

-

10603927.542999996

... More
S&F LED Retrofit Wellglass light fitting, flame proof type FLP-WP of 1X20 watt made of aluminium alloy LM6 with heat resistant and toughened glass cover,, painted MS wire guard and eye bolt including 01 No 20 watt LED lamp with connector block, etc and all accessories complete all as specified and as directed.

24

-

-

... More
Supply, installation, commissioning and testing of Servo Controlled Voltage Stabilizer factory assembled floor mounted, capacity 200 KVA, complete (As per BIS 9815 : part1:1994) with safety control and metering equipment mounted on common base frame on new PCC foundation required at site and as recommended by manufacturer, all as specified and as directed comprising of following:- a) Servo Controlled technology b) Type – Three Phase , outdoor , unbalanced c) Oil cooling type d) Testing- As per BIS 9815: Part 1 e) Input voltage – 300V-480V Ph to Ph f) Output voltage – 415+/-1% g) Frequency- 50Hz h) Rate of correction- 50V/sec, phase to phase j) Metering – Digital Microprocessor based k) Efficiency – Not less than 98% l) Responsible time- less than 10 mili second m) Break down strength – 2500 Ac for 2 minute n) Insulation Resistance (IR)- More than 100 Mega ohms at 500 v DC o) Capacity – 200 KVA p) Protections Provided- Over load , short circuit Protection , High/low voltage cut off, By pass arrangement, single phase preventer and oil temperature q) Copper winding r) 1st filling of oil NOTE:- (i) Voltage Stabilizer shall be suitably conditioned to suit the climatic condition of Purnea, so as to give desire outputs including and testing. (ii) Foundation of the Voltage Stabilizer (PCC/RCC) will be provided by the contractor and will be made as per the manufacturer instruction. Cost of foundation is deemed to be included in the rate of this item. (iv) Testing of Voltage Stabilizer will be carried out as specified.

1

-

-

... More
Supply and packing with Pea gravel of 2 mm to 3.5 mm size approved quality as ordered to packed around the casing/slotted pipe in bore well complete all as specified and directed.

20

-

-

... More
S&F MCB SP 6 to 32 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and directed.

24

-

-

... More
Trial bore holes 150 mm dia for exceeding 50mtr but not exceeding 100mtr in depth from ground Level in any type of strata for bore well if the same is found fit otherwise to fill up the same hole as directed by Engineer-in-Charge complete including submitting the strata details both graphically recommended as well as strata results as per IS- 2800 : 2000.

50

-

-

... More
Supply, installation, commisioning and testing floor mounted indoor cubical type LT Panel board (CPRI tested) suitabler to accomodate under mentioned accessories, fabricated out of not less than 2.0 mm thick CRCA sheet and angle iron 50X50X6mm frame, factory made totally enclosed, dust and vermin proof, both side hinge opening arrangement on front and back with locking arrangement, cable enty and exist from bottom with cable glands and gaskits alluminium busbar fixed on porcelin insulator with internal wiring with suitable size of alluminium strip to be used for incoming and outgoing connection of all Switches/MCCB's and bus bar's, bus bar shall be insulated with colour codes sleeves/tapes and to be connected with alluminium lux, powder coated with grey paint of approved shade on panel sheet duly 9 tank surface treated including necessary PCC(1:3:6) type C2 as in foundation all as directed comprising of the following :- Incoming (i) 40 Amp MCCB 4 pole 25 KA - 01 No (ii) Digital type voltmeter 0-500Volts with selector switch -1 Set (iii) Digital type ampere meter 0-100 Amps with CTs & selector switch -1 Set (iv) Indicator lamp- R-Y-B (set of three) (v) Alluminium bus bar rating 100 amp 4 way. Outgoing (i) 25 Amp MCCB 4 pole 16 KA- 03 Nos (ii) Single phase preventer having safety tripping for reverse phase, single phase, overload, over & under voltage-01No (iii) Starter for Air compressor 5HP cap - 01 No (iv) Space for Automatic Starter Star Delta suitable for 15HP Submersible pump set which shall be provided with pump under item Srl Item No. 15.30 here-in-before) Note :- Cost of cable glands, lugs/thimble and feeder identification marking shall be deemed to be included in the quoted lump sum.

1

-

-

... More
Construction of Soakage Well for 10 users complete all as shown on drawings and as specified.

2

-

-

... More
EXTERNAL WATER SUPPLY. Trial bore holes 150 mm dia for exceeding 0 mtr but not exceeding 50 mtr in depth from ground level in any type of strata for bore well if the same is found fit otherwise to fill up the same hole as directed by Engineer-in-Charge complete including submitting the strata details both graphically recommended as well as strata results as per IS- 2800 : 2000.

50

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.