Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Spl Repair To Bldg No P39g Or Living Accn Of Aro Provn Of 02 Nos Parking Shed Near Bldg No P6 And P47 Provn Of Security Light Infrastructure From Echs Polyclinic Gate To Near Bldg No P32 And Spl Repair Replacement Of Internal Wiring Of Ground in Patna, Bihar, with an estimated contract value of Rs. 42,14,000. The bid opening date for this tender is 22-05-2025 and the last date for bid submission is 13-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 May 2025
Closing Date13 Jun 2025
Tender Amount₹ 42,14,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only liquid water proofing compound ISI marked complete all as specified and directed.

1.3

-

-

... More
M&L for preparing old decorated plastered or unplastered surfaces of walls of any description by washing, rubbing down and applying one coat of distemper oil emulsion, white or tinted complete all as specified and directed.

30

-

-

... More
M & L for preparation of newly plastered surfaces of wall & concrete surfaces and applying 3mm thick wall care putty including preparation complete all as specified and directed.

55

-

-

... More
M&L for preparation of newly platered surface of walls and applying two coat of Oil Bound Distemper of any light shade over primer complete all as specified and directed.

55

-

-

... More
M&L for applying two coats of cement base paint on prepared new wall surfaces over a coat of primer complete all as specified and directed.

35

-

-

... More
M&L for applying two coats of cement base paint on old wall surfaces including preperation of surfaces etc complete all as specified and directed.

60

-

-

... More
Dismantling of Wall Panelling/ false ceiling board ,fiber insulation board any thickness including wooden cover fillets/ aluminium frame work complete all as specified and directed.

61

-

-

... More
S&F anodised aluminium snap grid ( size 605mm x 605mm) frame work for false ceiling with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and Exposed metal frame ceiling with calcium silicate board 6 mm thick of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified and directed.(Frame work for ceiling shall be measured and paid separately).

61

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.

80

-

-

... More
M&L for coloured Vitrified Ceramic tiles 10 mm thick Dark Shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tiles over and including 15 mm thick screed bed in cement sand mortar 1:6 complete all as specified and directed.

52

-

-

... More
All as per item No 13 above but on vertical surfaces as in skirting over and including 10 mm thick rendering in cement sand mortar 1:4 complete all as specified and directed.

10

-

-

... More
S&F Glazed Ceramic Coloured tiles on Vertical Surfaces of size 350X250X7 mm/450 X350X7 mm thick set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tiles over and including 10 mm thick rendering in cement sand mortar 1:4 complete all as specified and directed.

18

-

-

... More
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) complete with all fitting and fixture exceeding 1.5 Sqm but not exceeding 4 sqm complete all as specified and directed.

8

-

-

... More
M/L 35 mm thick factory made (batten thickness) Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned & chemically pressure treated complete all as specified and directed.

18.86

-

-

... More
S & F 35mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (with sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc fitted to chowkats for windows, ventilators,etc complete, size of member of shutter as specified in SSR Part -I, Sec 8, clause 8.20 (b).

18.86

-

-

... More
S&F Galvanised mild steel wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks etc complete all as specified and directed.

15

-

-

... More
S & F of pressed steel frame of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges lock strike plates etc complete all as specified and directed.

43.2

-

-

... More
M&L for hold fasts and similar small articles conforming to Fe -290 Gde E-165 complete all as specified and directed.

6.24

-

-

... More
M&L PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in filling in holes of hold fasts complete all as specified and directed.

0.42

-

-

... More
M&L for painting on new wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over one coat of pink primer including preparation surfaces complete all as specified and directed.

79.21

-

-

... More
M & L preparation of new steel surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed.

37.99

-

-

... More
S&F 200 mm long aluminum anodized barrel tower bolt of exturded section complete all as specified and directed.

32

-

-

... More
S&F 150mm long aluminum handles cast type anodized fixed complete all as specified and directed.

48

-

-

... More
S&F 100mm long butt hings medium weight cold rolled mild steel and fixed complete all as specified and directed.

72

-

-

... More
S&F 250 mm long aluminiunm anodized sliding door bolt with hasp and staple bolt type and fixing clips of sheet cast or extruded section fixing bolts and sliding bolts of extruded section complete all as specified and directed.

8

-

-

... More
Surface excavation n. exc 30cm deep & avergeing 15cm deep and getting out in soft/loose soil complete all as specified and directed.

120

-

-

... More
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.

155.55

-

-

... More
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.

78.34

-

-

... More
Excavation in post holes (or similar hole ) each n.exc 0.50 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layer not exceeding 25 cm complete all as specified and directed.

20

-

-

... More
S/F steel work in tubular trusses incl special shaped washer etc. Complete using ERW or induction built welded tubes conforming to IS 18573:2024

900

-

-

... More
M&L for sand filling under floors or in foundations, laid in layers n exc 15 cm thick, spread levelled including watering and consolidation complete all as specified and directed

18

-

-

... More
M&L old size brick work with sub class 'B' bricks laid flat in floors laid in dry complete all as specified and directed.

100

-

-

... More
M&L old size brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1.6 complete all as specified and directed.

4

-

-

... More
M&L 15mm thick rendering on fair faces of bricks work or concrete surfaces in cement mortar 1:6 finished even and smooth (without using extra cement) complete all as specified and directed.

50

-

-

... More
M&L Pre painted galvalume sheet aluminium zinc coating GI based corrugated steel sheet with curved type 0.5 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /ridge/cladding to wall fixed with self tapping screws as specified.(cut groves and put in sheet and covered with plaster at near bldg connecting sheds)

120

-

-

... More
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.

14.81

-

-

... More
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate),as in coping complete all as specified and directed.

1

-

-

... More
M&L Rubber moulded coloured chequered tile 20 cm x 20 cm x 20-22 mm thick, set, jointed and pointed in neat cement slurry in floors ( with grey cement and pigments) including Screed bed or bedding of mortar 20 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.

100

-

-

... More
Supply, laying, jointing & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of sizes 25 Sqmm 4 core complete all as specified and directed.

520

-

-

... More
Supply and fix steel tubular swaged poles type 410 SP-31 (9.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck,Including foundation and coping complete all as specified and directed.

15

-

-

... More
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.

15

-

-

... More
Supply and fix FRP street Light Pole Box, Size 300 x 200 x 125 mm,with DIN Rail for MCB including all fittings all as specified and directed.

15

-

-

... More
Supply and Fix MCB SP 6-32 Amps C series for Street light including all fittings all as specified and directed.

15

-

-

... More
M&L for wiring with two runs of 1.5 sqmm (Nominal area) single core PVC insulated stranded unsheathed copper conductor FRLS cable upto and including 1100 V grade drawn through PVC rigid conduit medium grade fixed to pole including one run of 1.5 sqmm (nominal area) single core, PVC insulated stranded unsheathed copper conductor FRLS cable as earth wire and duly connected to common earth point all as specified and directed including taking out old cables. (Note :-(i) One run of PVC rigid conduit with all fittings/accessories and Two runs of 1.5 sqmm single core cable and one run of 1.5 sqmm earth continuity wire to be measured as one unit length).

105

-

-

... More
Supply ,fabrication, installation and testing of LT out door type factory made CPRI Approved ,feeder piller box of made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5mm vertical legs frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) in foundation of suitable size and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and directed.

1

-

-

... More
Incoming : Copper strip busbar of 100 Amps current carrying capacity with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos. (a) MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 63 Amps including all fixing accessories with both ends spreader links -01 No. (b) Digital voltmeter of range (0-500) volts, flush mounting type of size 96mm x 96mm (4”x4”) square dial with selector switch – 01 No. (c) LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC -01 set (set of three).

-

-

-

... More
Outgoing

-

-

-

... More
MCB Single Pole 5 to 32 Amps,240 volts, 10 KA breaking capacity C curve - 03 Nos.

-

-

-

... More
TPN MCB four Pole 16 to 32 Amps,240 volts, 10 KA breaking capacity C curve - 01 Nos.

-

-

-

... More
Analog type time Switch, three moduled, 240 volts AC- 01 No.

-

-

-

... More
Power contactor 32 amps 3 Pole 415 Volts AC - 01 No.

-

-

-

... More
Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.

-

-

-

... More
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.

96.43

-

-

... More
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and directed.

42.12

-

-

... More
M & L old size sub class ‘B’ bricks, laid in trenches as cable covers complete all as specified and directed.

4.5

-

-

... More
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete all as specified and directed.

30

-

-

... More
M & L for Cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate ) as in foundations, filling and mass concrete complete all as specified and directed.

7.62

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR part I connected to earthing test point all as specified or indicated including testing on completion.

2

-

-

... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.

396

-

-

... More
Taking down carefully main switches DB's/ MCB DB's with MCB and making good the disturbed surfaces of walls as directed.

28

-

-

... More
Taking down carefully copper / aluminium sub main wiring including teak wood batten / conduit and making good the disturbed surface of walls as directed.

1860

-

-

... More
Refixing old serviceble any types of lumanirious like Tube light set, ceilling light, building security light etc, ceiling Fan, Exhaust Fan, wall mounted fan including all necessary fixing accesories, flexible wiring from ceilling rose to items complete all as specified and as directed. Note: Minor repairing like ball bearing, overhaulling for fans, cleaning, nut & bolts, screw etc are including in the quoted rate of this item.

255

-

-

... More
M & L for Point wiring with PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in surface wiring or concealed wiring system as per original ground requirement by cutting/chesing of wall and making good disturbed surface of wall with cement mortar and existing colour painting after fixing of conduit & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs for one light/fan point controlled by one switch complete all as specified and directed. (Note : wiring with 2 X 1.5 sqmm +1 X 1.5 sqmm run with proper colour code as per IE rules measured in one unit ) .

255

-

-

... More
All as per item No 59 above but one 5 Amps socket out let point controlled by one switch on same board with other switches.

37

-

-

... More
All as per item No 59 above but one 5 Amps socket out let point on independent board controlled by one switch.

32

-

-

... More
All as per item No 59 above but wiring with 2.5 sqmm single core copper conductor for one socket out let 5/15/16 amps point on the independent board. (Note : wiring with 2 X 2.5 sqmm +1 X 2.5 sqmm run with proper colour code as per IE rules measured in one unit)

58

-

-

... More
All as per item No 59 above but wiring with 4.0 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board.(Note : wiring with 2 X 4.0 sqmm +1 X 4.0 sqmm run with proper colour code as per IE rules measured in one unit)

14

-

-

... More
S & F Switch piano, flush type single pole, one way 6 Amp complete all as specified and directed.

292

-

-

... More
S & F electronic fan regulator 450 watt 240 volts AC step type complete all as specified and directed.

45

-

-

... More
S & F Socket outlet 2 in 1, 3 pin, 6A complete all as specified and directed.

37

-

-

... More
S & F Switch socket combination 2in 1, 6A flush type complete all as specified and directed.

32

-

-

... More
S & F Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal complete all as specified and as directed.

58

-

-

... More
S&F Single pole and neutral enclosure 240 volts with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.

14

-

-

... More
S & F ceiling rose 3 terminal PVC/polycarbonate isolated body type with necessary fittings complete all as specified and directed.

131

-

-

... More
S & F Lamp holder, PVC/Polycarbonate type with cord grip cap including all fittings complete all as specified and directed.

76

-

-

... More
M&L for Sub main wiring PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor three phase of size 16.0 Sqmm nominal cross sectional area ( for R,Y,B & N) & including non metallic rigid PVC conduit ISI marked medium grade with all conduit accessories in concealed wiring system by cutting/chesing of wall and making good disturbed surface of wall with cement morter and existing colour painting after fixing of conduit & one 16.0 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs complete all as specified and as directed. (Note : wiring with 4 X 16.0 sqmm +1 X 16.0 sqmm earth wire with proper colour code as per IE rules measured in one unit )

190

-

-

... More
M&L for Sub main wiring PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor three phase of size 10.0 Sqmm nominal cross sectional area ( for R,Y,B & N) & including non metallic rigid PVC conduit ISI marked medium grade with all conduit accessories in concealed wiring system by cutting/chesing of wall and making good disturbed surface of wall with cement mortar and existing colour painting after fixing of conduit & one 10.0 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs complete all as specified and as directed. (Note : wiring with 4 X 10.0 sqmm +1 X 10.0 sqmm run with proper colour code as per IE rules measured in one unit)

420

-

-

... More
M&L for Sub main wiring PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor single phase of size 6.0 Sqmm nominal cross sectional area ( for L & N) & including non metallic rigid PVC conduit ISI marked medium grade with all conduit accessories in concealed wiring system by cutting/chesing of wall and making good disturbed surface of wall with cement morter and existing colour painting after fixing of conduit & 6.0 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs complete all as specified and as directed. (Note : wiring with 2 X 6.0 sqmm +1 X 6.0 sqmm run with proper colour code as per IE rules measured in one unit )

380

-

-

... More
M&L for Sub main wiring PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor single phase of size 4.0 Sqmm nominal cross sectional area ( for L & N) & including non metallic rigid PVC conduit ISI marked medium grade with all conduit accessories in concealed wiring system by cutting/chesing of wall and making good disturbed surface of wall with cement morter and existing colour painting after fixing of conduit & 4.0 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs complete all as specified and as directed. (Note : wiring with 2 X 4.0 sqmm +1 X 4.0 sqmm run with proper colour code as per IE rules measured in one unit )

475

-

-

... More
M&L for Sub main wiring PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor single phase of size 2.5 Sqmm nominal cross sectional area ( for L & N) & including non metallic rigid PVC conduit ISI marked medium grade with all conduit accessories in concealed wiring system by cutting/chesing of wall and making good disturbed surface of wall with cement morter and existing colour painting after fixing of conduit & 2.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs complete all as specified and as directed. (Note : wiring with 2 X 2.5 sqmm +1 X 2.5 sqmm run with proper colour code as per IE rules measured in one unit )

395

-

-

... More
Supply and fixing double door TPN DBs 415 volts rated voltage eight way of powder coated DB's suitable for MCB's fitted with bus bar 200 A rated capacity,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site requirement complete all as specified and directed .

1

-

-

... More
Supply and fixing double door TPN DBs 415 volts rated voltage four way of powder coated DB's suitable for MCB's fitted with bus bar 200 A rated capacity,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site requirement complete all as specified and directed .

3

-

-

... More
Supply and fixing double door SPN DBs 240 volts rated voltage 12 way of powder coated DB's suitable for MCB's fitted with bus bar 200 A rated capacity,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site requirement complete all as specified and directed .

4

-

-

... More
Supply and fixing double door SPN DBs 240 volts rated voltage 08 way of powder coated DB's suitable for MCB's fitted with bus bar 200 A rated capacity,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site requirement complete all as specified and directed .

5

-

-

... More
Supply and fixing double door SPN DBs 240 volts rated voltage 04 way of powder coated DB's suitable for MCB's fitted with bus bar 200 A rated capacity,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site requirement complete all as specified and directed .

15

-

-

... More
Supply and fixing MCB TPN 40 to 100 amps 10 KA ,C-series, 415 Volt including connection with suitable size aluminium / copper lugs complete all as specified and directed .

4

-

-

... More
Supply and fixing MCB TPN 16 to 32 amps 10 KA ,C-series, 415 Volt including connection with suitable size aluminium / copper lugs complete all as specified and directed .

16

-

-

... More
Supply and fixing MCB SPN 240 volts 16 to 32 Amps, 10 KA breaking capacity, 'C' type including connection with suitable size aluminium / copper lugs complete all as specified and directed .

24

-

-

... More
Supply and fixing MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' type including connection with suitable size aluminium / copper lugs complete all as specified and directed .

100

-

-

... More
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables/ wall mounded by clip or concelled by cutting/chesing of wall and making good disturbed surface of wall with cement morter and existing colour painting after fixing, heavy duty with aluminium conductor of cross sectional area 35 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer, clamp etc complete as specified and directed.

90

-

-

... More
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables/ wall mounded by clip or concelled by cutting/chesing of wall and making good disturbed surface of wall with cement morter and existing colour painting after fixing, heavy duty with aluminium conductor of cross sectional area 50 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer, clamp etc complete as specified and directed.

50

-

-

... More
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables/ wall mounded by clip or concelled by cutting/chesing of wall and making good disturbed surface of wall with cement morter and existing colour painting after fixing, heavy duty with aluminium conductor of cross sectional area 120 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer, clamp etc complete as specified and directed.

120

-

-

... More
Supply, installation, commissioning and testing indoor LT Panel Board factory made CPRI approved panel, weather, dust & vermin proof outdoor cubical compartmental type, double door, front and back side openable, with providing rubber/PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/sleeves with maintained the colour code and copper strip busbar of suitable rating to MCCB input and MCCB output of suitable capacity, made out of 2.00 mm thick mild steel CRCA sheet with 40 x 40 x 6mm size angle iron supporting frame and MC 75 channel base including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 2.5 sqmm copper wire and connections of all outgoing / incomming including PCC foundation complete all as directed and specified and comprising of the following fitment accessories :-

1

-

-

... More
INCOMMING

-

-

-

... More
Copper strip busbar of current carrying capacity 400 Amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos.

-

-

-

... More
MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 250 Amps, adjustable thermal magnetic type, thermal release range (64 to 100 %) with O/L, S/C protection including all fixing accessories with both ends spreader links -01 Nos.

-

-

-

... More
LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three).

-

-

-

... More
Digital Ammeter of range (0-400) Amps, flush mounting type of size 100mm x 100mm (4”x4”) square dial with CT’s of ratio 630/5 and selector switch – 01 set.

-

-

-

... More
Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 Nos.

-

-

-

... More
OUTGOING

-

-

-

... More
MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 125 Amps, adjustable thermal magnetic setting type with O/L, S/C protection including all fixing accessories with both ends spreader links -02 Nos.

-

-

-

... More
MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=36 KA breaking capacity, rating 100 Amps, adjustable magnetic setting (from 3.5 to 10 In), thermal release range ( 64 to 100 %) with O/L, S/C protection including all fixing accessories with both ends spreader links -01 Nos.

-

-

-

... More
MCCB IP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable magnetic setting (from 3.5 to 10 In), thermal release range ( 64 to 100 %) with O/L, S/C protection including all fixing accessories with both ends spreader links -01 Nos.

-

-

-

... More
Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.

-

-

-

... More
Supply and fixing LED lights fitting 1x 18 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.

77

-

-

... More
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed/ ceilling mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.

48

-

-

... More
Supply and fixing LED lamp 9 watt 220V,AC complete all as specified and directed.

76

-

-

... More
Supply and fix wall mounted fan, AC single Phase. 230V of size 600mm sweep with, including all fixing arrangement complete all as specified and directed.

9

-

-

... More
Supply and fixing of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.