Military Engineer Services Tender
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.
Costs
EMD
₹ 39,980Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_673051_3Tender No
GE/DNR/T-44 OF 2024-25 / 8817/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as srl item No 5 above but for additional 1.5 m or part thereof in depth beyond the first 1.5m in hard/dense soil all as directed.
0.2
-
-
... More
M & L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete.
3.5
-
-
... More
M & L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete.
0.2
-
-
... More
Supply and fix steel tubular swaged poles type 410SP-31 (9.0 meter long) with cast iron base plate , finial taper plug, bolts, nuts & screws as speciifed and as directed. Note for item 4 - Excavation , earthwork, PCC will be measured and paid seperatly under respective item .
6
-
-
... More
Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed.
161
-
-
... More
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
120
-
-
... More
Supply and laying dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed.
(Note : Punned thickness shall be mesured & paid)
83
-
-
... More
Supply and laying sub class B bricks of size 25cmx12.5cmx7.5cm for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
6
-
-
... More
Laying only bricks obtained from item No: 3 for protection of UG cable complete all as specified and as directed.
2000
-
-
... More
M & L for horizontal boring mechanically across the existing road without disturbing the road surface for inserting 80/40 mm bore GI pipe all complete all as specified and as directed by EIC. ( Note :- GI pipe will be measured and paid respective item of sch'A').
15
-
-
... More
S & F MS Galvanised chain link fencing 3.40 mm dia & 100X100 mesh including line wires weight of mesh shall n.exc. 4.00 Kg/Sqm.
80
-
-
... More
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete. Make - TATA / JINDAL / Prakash Surya
120
-
-
... More
Supply and fixing of GI tubing, light grade, 80 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete. Make - TATA / JINDAL / Prakash Surya
80
-
-
... More
Laying only cable any sizes obtained from item No 3 with all new fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed.
350
-
-
... More
Digging out incoming and outgoing cables of any sized from loops near/back side junction box/feeder pillar box/ LT panel in trenches, cutting burnt out uninsulated portion of cable and relaying refixing in trenches and returning, refilling the excavated soil and connecting the cables with bus bars including provision of suitable size of aluminium lugs, complete all as specified and as directed.
12
-
-
... More
Supply, fabrication, installation and testing of LT factory made CPRI approved water and vermin proof protection pedestal type feeder pillar box of minimum size 1000mm (Height) x 600mm (Breath) x 400mm (Depth), outdoor type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable and air ventilation arrangement including provision of cable looping box of size 450mm (Height) x 600mm (Breath) x 300mm (Depth) made out of 3 mm thick CRCA sheet with front side openable double door shutter hinged door and locking arrangement at back side complete painted with Powder Coated paint of approved shade and suitable for 3 phase 4 wire system 500 voltage grade complete wiring and all incoming connections with copper strip busbar of required size to MCCB input including PCC (1:3:6) type C-2 as in foundation of size 0.80m x 0.60m x 0.60m depth (30 cm below ground level & 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed alongwith comprising of the following accessories :- NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item.
1
-
-
... More
Aluminium strip busbar of current carrying capacity 400 amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with suitable size GI nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos.
-
-
-
... More
Copper strip busbar of current carrying capacity 200 amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with suitable size GI nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos.
-
-
-
... More
MCCB adjustable thermal magnetic release type of IP 66 protection,4 poles, 415 Volts, Lcu = 100% Ics, 36 KA breaking capacity of rating 250 Amps including all fixing accessories with both ends spreader links - 01 No. (Make :- L& T / Legrand/Schneidder
-
-
-
... More
MCCB adjustable thermal magnetic release type of IP 66 protection,4 poles, 415 Volts, Lcu = 100% Ics, 25 KA breaking capacity of rating 64 Amps including all fixing accessories with both ends spreader links - 04 No. (Make :- L& T / Legrand/Schneidder
-
-
-
... More
Neon indicator lamp with holder (RYB) = 03 Nos (L&T/AE/C&S).
-
-
-
... More
Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
-
-
-
... More
Neon indicator lamp with holder (RYB) = 03 Nos (L&T/AE/C&S).
-
-
-
... More
Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
-
-
-
... More
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 300 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (Make: HAVELLS/ POLYCAB/MESCAB) (NOTE: Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this schedule 'A' part).
125
-
-
... More
All as per ser item No 20 above but of cross sectional area 120 sqmm 3.50 core
275
-
-
... More
All as per ser item No 20 above but of cross sectional area 95 sqmm 3.50 core
210
-
-
... More
All as per ser item No 20 above but of cross sectional area 25 sqmm 4 core
275
-
-
... More
All as per ser item No 20 above but of cross sectional area 16 sqmm 4 core
240
-
-
... More
All as per ser item No 20 above but of cross sectional area 10 sqmm 2 core
375
-
-
... More
M & L for PVC insulated, stranded aluminium conductor served with inner sheathing PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm dia GI suspension wire of wire 10 Sqmm 2 core,complete all as specified and directed .Makes of cable : Finolex/Indo -Asian/Standard/ Havells/ Polycab .
220
-
-
... More
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 240 to 300 sqmm 3.5 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
4
-
-
... More
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 150 to 185 sqmm 3.5 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
4
-
-
... More
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 70 to 120 sqmm 3.5 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
4
-
-
... More
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 25 to 50 sqmm sqmm 3.5 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
5
-
-
... More
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 10 to 16 sqmm 4 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
5
-
-
... More
Supply, fixing and testing of heat shrink LT XLPE cable outdoor end termination jointing kit suitable for 1100 volts grade 240 to 300 sqmm 4/3.5 core cable complete all as specified and as directed. Make : Raychem / 3M / Denson.
2
-
-
... More
Supply and fixing MCCB adjustable thermal magnetic release type, 4 poles, 415 Volts, Lcu = 100% Ics, 36 KA breaking capacity of rating 400 Amps including all fixing accessories with both ends spreader links and disconnecting and taking out old U/S MCCB complete all as directed. Make -Simence / Legrand / L&T.
3
-
-
... More
Supply and fixing MCCB adjustable thermal magnetic release type, 4 poles, 415 Volts, Lcu = 100% Ics, 36 KA breaking capacity of rating 160-200 Amps including all fixing accessories with both ends spreader links and disconnecting and taking out old U/S MCCB complete all as directed. Make -Simence / Legrand / L&T.
3
-
-
... More
Supply and fixing MCCB adjustable thermal magnetic release type, 4 poles, 415 Volts, Lcu = 100% Ics, 36 KA breaking capacity of rating 100-125 Amps including all fixing accessories with both ends spreader links and disconnecting and taking out old U/S MCCB complete all as directed. Make -Simence / Legrand / L&T.
5
-
-
... More
Supply and fixing MCCB adjustable thermal magnetic release type, 4 poles, 415 Volts, Lcu = 100% Ics, 25 KA breaking capacity of rating 63 Amps including all fixing accessories with both ends spreader links and disconnecting and taking out old U/S MCCB complete all as directed. Make -Simence / Legrand / L&T.
NOTE FOR ITEM NO- 33 TO 36 :- MCCB shall be replaced as per existing frame size/ Model and as per requirement of site.
5
-
-
... More
Supply and fixing in repair for three phase Amp meter digital type size 96 mm x 96mm square flush type complete all as specified and as directed.
10
-
-
... More
Supply and fixing in repair Indication lamp (RYB) LED type 240 volts AC 50 Hz complete all as specifeid and as directed.
15
-
-
... More
Supply and fixing in repair for three phase Voltmeter digital type of range 0-500V complete all as specifed and as directed.
10
-
-
... More
Supply and fixing in repair Voltmeter selector switch for (0-500 volts) voltmeter as per sample / existing model complete all as specified and as directed.
10
-
-
... More
Supply and fixing in repair Ammeter selector switch for (0-100 Amps) Ammeter as per sample / existing model complete all as specified and as directed.
10
-
-
... More
Supply and fixing in repair current transformer (CT) 240 volts 50 Hz of ratio 100/5A, 200/5A as per existing size and model complete all as specified and as directed.
10
-
-
... More
Supply and fixing in repair for in changeover switch disconnector in sheet steel enclosure type 4 pole 415 volts AC of current rating 125 Amps including disconnecting and taking out unserviceable one complete all as directed. Make - L&T, Cat No: CO21250OSOO / Havells / HPL .
1
-
-
... More
S & F in repair checking, cleaning of electrical control panel including replacement of following items and connecting existing parts complete all as required at site and directed by Engr-in-Charge.
-
-
-
... More
3 pole power capacitor 10 KVAR . Make - L&T / Legrand / Schneider .
1
-
-
... More
3 pole power capacitor 5 KVAR . Make - L&T / Legrand / Schneider .
2
-
-
... More
APFC controller for Contactor switching with 1 CT input Measurement of individual Current and Voltage harmonic (THD) up to 15th Order for 5 Step APFC Controller + 2 Step Plug-in module. Make - L&T / Legrand / Schneider .
2
-
-
... More
M&L in repair checking, cleaning & servising of Voltage Servo stabilizer of 400 KVA including replacement of gaskit, nuts and bolts and minor repair of connecting existing parts complete all as required at site and directed by Engr-in-Charge
1
-
-
... More
M&L in repair checking, cleaning & servising of Voltage Servo stabilizer Syncronising motor of upto 30 KVA including necessary items complete all as required at site and directed by Engr-in-Charge
1
-
-
... More
M&L in repair checking, cleaning & servising of Voltage Servo stabilizer Syncronising motor of 3 X 25 KVA including necessary items complete all as required at site and directed by Engr-in-Charge
1
-
-
... More
Supply and fixing in repair MCB SPN 5 to 40 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed .
8
-
-
... More
Supply and fixing in repair MCB SP 240 volts 5 to 32 Amps, 10 KA breaking capacity, 'C' type including connection with suitable size aluminium / copper lugs complete all as specified and directed .
20
-
-
... More
Supply and fixing in repair MCB TPN 50 to 63 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed .
6
-
-
... More
Supply and fixing Digital Electronic Trivector meter Class 0.5, 3 Phase 4 wire system 240 volts with optical port for measuring the complete data. Make: L&T /Secure/HPL.
1
-
-
... More
Material and labour LT Cable rout indicator made out of PCC Post of 1:2:4 using 20mm graded stone aggregate of size not less than 20 x 15 cm and one meter height with making embossing the following letters of size 100 mm in the PCC Post " LT CABLE with ARROW" including necessary excavation and PCC 1:2:4 using 20mm graded stone aggregate (30 X 30 x 30 CM ) for embeding in the ground complete all as specified and directed.
85
-
-
... More
M&L in repair prepration of old painted surfaces steel / Iron of any description over 10 cm in width or girth not otherwise described and two coats of synthetic enamel painting in existing surface after proper cleaning complete all as specified and directed. (Note:- Painting of panels / feeder filler boxes shall be carried out in different colour of paints as required at site and as directed.)
40
-
-
... More
Attend faults of LT cable/ street light fittings out door electrical fixtures asper any rating/ make/ model/ type in position including testing of serviceability of cables and fittings, finding fault/ defect and repairing proper jointing of wires/cables with reqd jointing materials and making wiring functional complete all as specified and directed by Engr-in-Charge. Note:- (i) The rate quoted is excluding electrical fitting & fixtures, cable and major items. (ii) The rate quoted is including the repairing tools & insulation tape (iii) Provn of cables/ street light accessories and fittings incl taking down of the same will be paid under relevant items. (iv) Collection of daily complaints from complaint cell will the responsibility of the contractor. (v) Contractor shall be responsible to submit the all rectified complaints to JE incharge after completion on daily basis (vi) Electrician and helper shall be arranged by contractor.
450
-
-
... More
M&L in reapir for replacement of MS sheet cover of LT panel board made out of 2.00 mm thick MS sheet as per required shape and size including necessary fabrication,welding work and fixing accessories etc to match with existing panel surface complete all as specified and directed.
6
-
-
... More
M & L in repair for Earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip, buried in ground or fixed to wall in repair complete.
30
-
-
... More
M & L for Earthing to OH/Sub stn with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 32 x 6 mm galvanised iron strip dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No3 of MES Schedule pt-I 2009, GI earth strip 32 x 6 mm protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements