Food Corporation Of India Tender

... More
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

Food Corporation Of India - FCI Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Aug 2024
Closing Date19 Aug 2024
Tender Amount₹ 37,61,705 
Notes
Download

Costs

Summary

Armo Works Of Electrical Installations Including, Replacement Of Existing Overhead Lines With Ug Cables, Rewiring And Replacement Of Existing Conventional Light Fittings With Energy Saving Led Light Fittings For Depot Office, Do Office At Fsd, Buxar.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and fixing of 03 Nos 500 A Porcelain Kit Kat Rewireable fuse units (Fuse carrier & Base) & neutral link and fixing on the wall by using 1 mtr x 1 mtr X 20 mm Ply wood sheet including giving connections etc, at site of work as required.

1

10224

-

... More
Providing and fixing following rating and breaking capacity MCCB of item code , with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 Amp, 36 KA, TPMCCB

4

98140

-

... More
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 320amp,50KA,TPMCCB

1

30303

-

... More
Supply & fixing of Kit-Kat 95 Sq mm lugs with all necessary part at required place

16

1312

-

... More
Supplying of XLPE Armoured cable with aluminium conductor of 1.1 KV grade confirming to IS:7098 (Part- I) 1988 with up to date ammendments of the following size as required. , (a) 3.5 Core70 sq. mm. armoured cable

250

305500

-

... More
(b) 3.5 Core 50 sq. mm. armoured cable

250

226500

-

... More
(c)3.5 Core 25 sq. mm. armoured cable

250

124500

-

... More
(d) 4 Core 16 sq. mm. armoured cable

550

247500

-

... More
(e) 3 Core6 sq. mm. armoured cable

600

154200

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size direct in ground including excavation, sand cushioning,protective covering and refilling the trench etc as required. (a) Upto 35 sq. mm

874

338238

-

... More
(b)Above 35 sq. mm and upto 95 sq. mm

436

176580

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. a) Upto 35 sq. mm (clamped with 1mm thick saddle)

274

15070

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. (a) Upto 35 sq. mm

336

90384

-

... More
(b)Above 35 sq. mm and upto 95 sq. mm

10

2860

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.(a) Upto 35 sq mm.

111

4107

-

... More
(b)Above 35 sq. mm and upto 95 sq. mm

36

2052

-

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as require 100 mm dia.

54

97524

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. (a)120 mm dia (OD-120 mm & ID-103 mm nominal)

18

4464

-

... More
Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.

15

38460

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3.5 x 50 sqmm (35mm)

2

826

-

... More
(b)3½ X 70 sq. mm (38mm)

2

936

-

... More
(b) 3½ X 25 sq. mm (28mm)

2

626

-

... More
(c) 4 X 16 sq. mm (28mm)

16

4944

-

... More
(d) 2 X 10 sq. mm (19mm)

10

2570

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.(a) Group C

124

181908

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 6 X 2.5 sq. mm

268

71020

-

... More
b) 3 X 2.5 sq. mm

128

17536

-

... More
c) 6 X 4 sq. mm

124

49104

-

... More
d) 3 X 4 sq. mm

112

23072

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (a) 4 X 2.5 sq. mm + 2X 2.5 sq. mm earth wire

295

120950

-

... More
(a) 2 X 2.5 sq. mm + 1X 2.5 sq. mm earth wire

284

78100

-

... More
(b)4 X 4 sq. mm + 2X 4 sq. mm earth wire

82

44034

-

... More
(b)2 X 4 sq. mm + 1X 4 sq. mm earth wire

242

80828

-

... More
©2 X 10 sq. mm + 1X 6 sq. mm earth wire

43

24510

-

... More
Supplying and drawing of 1.5 Sq.mm,three core PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 in the existing surface/ recessed steel/ PVC conduit as required.

160

16800

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door

1

7512

-

... More
Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)

6

24546

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a)8 way, Double door

8

18520

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way

6

13236

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole

80

20480

-

... More
(b) Single Pole & Neutral

54

32346

-

... More
(c) Triple pole & Neutral

8

9824

-

... More
(d)Triple pole

3

3021

-

... More
Supplying, installation, Testing and commissioning of 70 watt LED type Well Glass luminaires in pressure die-cast aluminium housing with IP 66, System efficacy of ≥110 lm/W,colour temp 5700 K,THD( %) ≤ 10, Polycarbonate diffuser in opal finish and fixing on truss with suitable clamps and nut bolts and also dismantling the existing fitting etc at the site of work as required.

30

267870

-

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.

26

70980

-

... More
Supply and fixing of 36W LED General Purpose Battens with extruded Al body (Length≥1185mm), Milky white, polycarbonate diffuser and inbuilt driver with efficacy min of 100 lumens/W along with Highly robust Industrial Box type luminaire suitable, THD( %) 10 at the site of work.

48

79104

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. (a) 6 Module (200mm X 75mm)

5

2010

-

... More
12 Module (200mmX150mm)

65

35555

-

... More
(b)3 Module (100mmX75mm)

14

4578

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (a) 15/16 amps Switch

284

44304

-

... More
(b) 25 A SP C Mini MCB

14

6846

-

... More
(c) 6 pin 15/16 amp socket outlet

284

55948

-

... More
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/cocke and salt as required.

6

41130

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

72

5040

-

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

31

8897

-

... More
Supplying and fixing of 3 phase (RYBN), 100 A, 4 way, wall mounted aluminium BusBar chamber in sheet steel enclosure etc, at site of work as required.

3

34059

-

... More
Dismantling of pole/ street light standard/ strut embedded in brick ballast foundation etc. as required.

38

76114

-

... More
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.

500

43500

-

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

2.16

4335

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)

2.16

14760

-

... More
Provided & fixing 63 Amp Phase Selector rotary switch with steel enclosure and indicator on wall of godown including connection etc. as required.

2

3254

-

... More
Dismantling of existing old iron, aluminium and other scrap at any height along with accessories from surface/recess as required for disposal of the same.

260

12480

-

... More
Disposal of Dismantled ACSR Conductor

500

-65000

-

... More
Disposal of Dismantled Aluminium Scraps (Wires etc)

260

-6500

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.