Eastern Railway Tender

... More
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

Eastern Railway - ER Tender

Works
Transportation and Logistics
Ireps
Opening Date21 Feb 2025
Closing Date14 Mar 2025
Tender Amount₹ 9,11,40,459 
Notes
Download

AI Insights

Bid Capacity
... View More
The minimum average annual contractual turnover = V/N or V, whichever is less, where V = 83220.00 and the number of years N is not provided. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years. The tenderer must have successfully completed or substantially completed any of the following during last 07 years: - Three similar works each costing not less than 30% of advertised value of the tender (so 30% of 83220.00) - Two similar works each costing not less than 40% of advertised value of the tender (so 40% of 83220.00) - One similar work each costing not less than 60% of advertised value of the tender (so 60% of 83220.00).
Technical Capacity
... View More
The bidder must have successfully completed or substantially completed similar works with specific cost requirements. The requirements include: - Three similar works each costing not less than 30% of the advertised value of the tender, - Two similar works each costing not less than 40% of the advertised value of the tender, - One similar work each costing not less than 60% of the advertised value of the tender. The work experience is considered valid if it occurred within the last 7 years and if the certificates are from government organizations or public listed companies with an average annual turnover of Rs 500 crore and above, provided they are issued by authorized personnel and accompanied by supporting documents.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removal of defective Blower Motor and fitment with new one with released blower runner(A + B). (Defective material to be returned to consignee store).

50

2351

117550

... More
Supply of new Condenser fan motor 1HP/1400 RPM with TOP & Rain Guard (Rubber Cap) (Make-RDSO approved source) SR- 075-1028.

200

14750

2950000

... More
Supply of new Condenser fan motor 1HP/1400 RPM with TOP & rain guard (rubber cap) (Make-VEM).

10

44250

442500

... More
Removal of defective Condenser fan motor & fitment of new one. Released fan Blade & necessary modification work to be done by firm. If reqd. (Defective to be returned to consignee store). 8

210

1770

371700

... More
Supply of new FRP fan blade with Aluminium hub (SR075-1036)

200

4425

885000

... More
"Removal of defective FRP blade with Aluminium hub & fitment with new one (SR-075- 1036)(Defective to be returned to consignee store)." 10

-

-

9

... More
Supply of new SS welded round guard. (SR-075-1041)

10

2909

29090

... More
Removal of defective SS welded round guard & fitment with new one (Defective to be returned to consignee store).

10

1061

10610

... More
Leak testing of refrigerant system by charging N-2 gas. (N-2 gas will be supplied by firm)

300

2950

885000

... More
Rectification of leakage of refrigerant circuit by charging N-2 gas as per SMI & charging of refrigerant (Brazing Kit, Vacuum pump, N2 gas , refrigerant gas required to be supplied by the firm). 14

300

2978

893400

... More
Supply of drier filter (1/2" solder type) SR-075-1019

150

2596

389400

... More
"Removal of drier filter (1/2"" solder type SR-075-1019 and refitment by new one. (all associated jobs i.e. brazing alongwith all type of gas, systems flashing with N2, leak test as per SMI, Vacuum pump required will be supplied by firm) (Defective to be returned to consignee store)" 16

150

7670

1150500

... More
Supply of new Hartige (Couplers screw type) connector 24 pin SR-G75-1001

40

9697

387880

... More
Removal of defective / damaged Hartige (Couplers) connector 24 pin & re-fitment with new one. (Defective to be returned to consignee store). 18

40

2651

106040

... More
Supply of new Hartige (Couplers screw type) connector 16 pin SR-075-1002

20

8485

169700

... More
Removal of defective / damaged Hartige (Couplers) connector 16 pin & re-fitment with new one. (Defective to be returned to consignee store). 20

20

2351

47020

... More
Supply of new Pressure Transmitter (0-10 bar) SR-075-1010

40

8850

354000

... More
"Removal of defective Pressure Transmitter and replacement with new one SR-075- 1010 (all associated jobs i.e. brazing leak testing etc. alongwith all types of gas and vacuum pump required will be supplied by firm (Defective to be returned to consignee store)." 22

40

2651

106040

... More
Supply of new Pressure Transmitter (0-40 bar) SR-075-1011

40

8850

354000

... More
Removal of defective Pressure Transmitter (0-40 bar) and replacement with new one SR-075- 1011 . (all associated jobs i.e. brazing leak testing etc. alongwith all types of gas and vacuum pump required will be supplied by firm (Defective to be returned to consignee store). 24

40

2651

106040

... More
Supply of new protection for Heater (OHP) SR-075-1066

180

1879

338220

... More
Removal of defective protection for Heater (OHP) & replacement by new one. (Defective to be returned to consignee store). 26

180

2950

531000

... More
Supply of new glass bulb cartidge + 130°C of SR-075-1015.

200

2065

413000

... More
Removal of glass bulb cartidge + 130°C and replacement by new one SR-075-1015. (Defective to be returned to consignee store). 28

100

444

44400

... More
Supply of new ESTI switch assembly with cartridge SR-075-1014

30

15930

477900

... More
Removal of defective ESTI switch assembly with cartridge replacement by new complete assembly SR-075- 1014.(Defective to be returned to consignee store)

30

885

26550

... More
Supply of new Air Heater set consisting 400w (15 nos.) coil with insulated bakelite sheet.

-

-

30

... More
Removal of defective Air Heater set & replacement by new one. (Defective to be returned to consignee store) 32

20

1770

35400

... More
Supply of new low pressure control switch (auto reset) SR-075-1037

150

3540

531000

... More
"Removal of defective low pressure control switch KP - 1 (auto reset) and replacement 33 by new one SR-075- 1037 (All associated jobs e.g. brazing, leak testing etc. along with all types of Gas and Vacuum Pump required to be supplied by the Firm) Alco make to Alco make and Danfoss make to Alco make Danfoss make-KP-1/Alco make- P53-AP3 HNK4/1.5b..(Defective to be returned to consignee store)"

150

3144

471600

... More
Supply of new high pressure control switch(auto reset) SR-075-1038 . (Alco make to Alco make and Danfoss make to Alco make) Danfoss makeKP-5/Alco make- PS3-WP5 HNK27/21.

150

3920

588000

... More
"Removal of defective high pressure control switch (auto reset) and replacement by new one (All associated jobs i.e. brazing, leak testing etc. along with all types of Gas and Vacuum pump required to be supplied by the Firm).(Defective to be returned to consignee store)"

150

3144

471600

... More
Supply of new high control pressure switch (auto reset). ( Danfoss make to Alco make) Danfoss make-KP5/Alco make- PS3-AP4 HNK23/204/-0.3 bar

60

3629

217740

... More
"Removal of defective control pressure switch (auto reset) and replacement by new 37 one PS3-AP4 HNK 23/20±0.3 bar Alco & Danfoss (All associated jobs e.g. brazing, leak testing etc. along with all types of Gas and Vacuum pump required to be supplied by the Firm)..(Defective to be returned to consignee store)" 38

60

3144

188640

... More
"Supply of new Expansion valve (Make-RDSO approved source)"

90

7080

637200

... More
Removal of defective Expansion valve and refitment by new one (Make-RDSO 39 approved source) (All associated jobs e.g. brazing, leak testing as per SMI etc.along with all types of Gas, system flashing with N2 and Vacuum pump required to be supplied by the Firm). (Defective to be returned to consignee store) 40

90

8850

796500

... More
Supply of new liquid cum moisture indicator , SR-075-1021

15

1460

21900

... More
Removal of defective liquid cum moisture indicator ,SR-075-1021. (All associated jobs i.e. brazing, leak testing etc. along with all types of Gas and Vacuum pump required to be supplied by the Firm)..(Defective to be returned to consignee store) 42

15

4057

60855

... More
Supply of Evaporator coil-Left hand,SR-075-1042, /Right hand SR- 075-1043.

72

59000

4248000

... More
Removal of defective Evaporator coil- Left hand /Right hand with drier & replacement 43 with new one as required (All associated jobs i.e. brazing, leak testing etc. along with all types of Gas, system flashing with N2, leak test as per SMI, Vacuum pump required to be supplied by the Firm). (Defective to be returned to consignee store) 44

72

14160

1019520

... More
Supply of new condenser coil-Left hand, SR-075-1044/Right hand SR - 075-1045.

50

76936

3846800

... More
Removal of defective condenser coil Left hand ,SR-075-1044./Right hand SR-075-1045 45 with drier & re fitment with new one as required (All associated jobs e.g. brazing, leak testing etc. along with all types of Gas and Vacuum pump required to be supplied by the Firm).(Defective to be returned to consignee store) 46

50

14160

708000

... More
Supply of high pressure gauge (HP) (0-40 bar) SR-075-1053 .

12

10620

127440

... More
Replacement of defective high pressure gauge (HP)( 0-40 bar) SR - 075-1053 with new one .

12

2950

35400

... More
Supply of low pressure gauge (LP)( 0-10 bar) (Sitam make) SR-075-1052

-

-

48

... More
Replacement of defective low pressure gauge (LP)( 0-10 bar) (Sitam make) SR-075- 1052 with new one 50

12

2950

35400

... More
Supply of new Rotary switch of AC "OFF-ON" SR-075-1048

20

1394

27880

... More
Removal of defective Rotary switch of AC "OFF-ON" & re-fitment with new one SR-075- 1048. (Defective to be returned to consignee store)

20

784

15680

... More
Supply of Selector switch for pressure gauge meter for four no. compressor SR-075- 1050 and fitment with new one (Defective to be returned to consignee store)

12

2065

24780

... More
" Supply of new air duct complete with meta Aramid fabric having silicon rubber coating on both sides including frame and associated accessories for all makes of LHB AC Coaches SR-075-1056."

75

37760

2832000

... More
Removal of defective return air duct & refitment of new one with sealant compound associated accessories.(Defective to be returned to consignee store)

75

8850

663750

... More
" Supply of new set of 2 nos return air duct complete with Meta Aramid fabric having silicon rubber coating on both sides including frame and associated accessories for all makes of LHB AC Coaches SR-075-1055 . "

75

15340

1150500

... More
Removal of defective return air duct & re-fitment of new one with Sealant compound & associated accessories.(Defective to be returned to consignee store)

75

2950

221250

... More
" Supply of new 2 nos fresh air duct with Meta Aramid fabric having silicon rubber coating on both sides including frame and associated accessories in all types of LHB AC Coaches SR- 075-1054."

36

14160

509760

... More
Removal of defective fresh air duct & re-fitment of new one with associated accessories. (Defective to be returned to consignee store)

36

1933

69588

... More
Supply of new compressor contactor type # LS 18K#00#DC110V(with diode on HS 7K 10)77-137 V DC AEG make or TAL 40-30 01+RT5/150 CAS-22 M ABB make or RDSO/RCF approved make.

100

6051

605100

... More
Removal of defective compressor contactor & replacement of new one. (Defective to be returned to consignee store)

50

813

40650

... More
Supply of new condenser motor contactor type #LS 4K 10E(with diode ) 77-137 V DC AEG make or TAL 16-30-01/110V DC+RT5/150+ CAS-01 ABB make or RDSO/RCF approved make.

100

3920

392000

... More
Removal of defective condenser motor contactor & replacement of new one. (Defective to be returned to consignee store)

50

813

40650

... More
Supply of new blower motor contactor type #LS 4K 10B(with diode on HS 7K 01 ) 77- 137 V DC AEG make or TAL 16-30 01/110V DC+RT5/150+ CAS-01 ABB make or RDSO/RCF approved make.

36

3920

141120

... More
Removal of defective blower motor contactor & replacement of new one. (Defective to be returned to consignee store) 65

36

813

29268

... More
Supply of new DC/DC converter 110V/24V 1.5A type CPRE-24V/2.5A ABB make

30

6363

190890

... More
Supply of new blower motor runner of different make (A type+B type) with new one as per RDSO approved make and site demand (Supply to be done as per demanded make of RMPU package).

50

8831

441550

... More
Removal of defective blower motor runner & replacement of new one. (Defective to be returned to consignee store)

-

-

67

... More
Supply of new blower housing complete of different make (Sidwal,Daulatram, SSK, Fedders and as per site demand) with motor and runner by new assembly.

15

32163

482445

... More
Removal of defective blower housing complete with motor and runner & replacement of new one. (Defective to be returned to consignee store)

15

2950

44250

... More
"Supply of new double inlet centrifugal blower, 415V, 3 Phase, 50Hz, 120W, 450 m3/hr discharge for exhausting air from lavotory/switch Board cabinet make-RDSO approved source."

90

17700

1593000

... More
Removal of double inlet centrifugal blower, 415V, 3 Phase, 50Hz, 120W, 450 m3/hr discharge for exhausting air from lavotory/switch Board cabinet & replacement of new one with duct if required. (Defective to be returned to consignee store)

90

1770

159300

... More
"Supply & replacement of new multifunctional monitoring relay for 3 phase main suitable for 750V system, monitoring phase parameter , phase sequence, phase failure over and under voltage and phase unballanced (make-Carlos Ga vazee) Type No-CM-MPN.72 or similar."

350

18422

6447700

... More
Supply & replacement of new DC/DC converter 110V/24V, 10A Model No.300-SL-24 or equivalent model make-Powertech, ABB,Cosel, Aptech .

36

18880

679680

... More
Supply of ceiling compound 2 Nos. (280 ml), cleaning agent orion-510D (05 lit) during schedule attention of AC Coaches (for one RMPU unit & material should be supply to consignee store)

1400

5015

7021000

... More
Cleaning of Condenser and cooling coil, with high pressure water jet, tightness checking, greasing of all motors during schedule attention of AC Coaches, cleaning of return air filters, fresh air filter after removing from RMPU to be replaced with new one if found unserviceable 75 and refitment with new one inside duct diffuser and return grill cleaning with brush and air blower by duly opening celling, return grill and refixing the same and testing with proper instrument reading of Amp of various motors and refrigerant pressure, air flow measurement to be recorded Microprocessor data to be downloaded and to be submitted to SSE/concerned . Using Laptop, high pressure water jet, air blower, & other equipment must be supplied by the firm.

1400

5310

7434000

... More
Supply and replacement of defective manual valve (1/4") by new one (RDSO approved make materials to be supplied).

40

6726

269040

... More
Supply and Replacement of defective Hinges/latch lock of side Entry hood cover (Return Air filter cover) by new one (RDSO approved materials to be supplied). 78

30

994

29820

... More
Supply of Strainer capillary (RDSO approved materials to be supplied)

100

1892

189200

... More
Removal of defective Strainer capillary with drier and fitment by new one (All 79 associated jobs e.g. brazing, leak testing etc. along with all types of Gas system flashing with N2, leak test as per SMI, Vacuum Pump required to be supplied by the Firm) (Defective to be returned to consignee store)

100

7670

767000

... More
Supply and Removal of defective Brass distributor 8 hole inlet 19 small SR-075-1028 and replacement by new one. (RDSO approved materials to be supplied)

6

939

5634

... More
Supply and replacement of defective Hygrostat 35-100%. (Make-RDSO approved source) with new one. (Defective to be returned to consignee store) 82

15

18262

273930

... More
Supply of Insulation Control relay 415V Net Make- ABB Cat No: CM.IWS.2S 83

36

16941

609876

... More
Supply of Insulation Control relay 110V Net Make- ABB Cat No: CM.IWS.1S 84

36

17811

641196

... More
Supply of Voltmeter NW 72 for 110 v DC , 0-150V , Make:AE/Rishabh/Yokins/L&T

36

2162

77832

... More
Supply of Voltmeter NW 72 for NET1 & NET2 , 0-800V ; 800V AC Make:AE/Rishabh/Yokins/L&T

-

-

85

... More
"Supply of Feeder Contactor NET1 & NET2, Voltage :750V AC, Current200A, Pole: 4NO, with 2NO+2NC, control Voltage: 380-415V AC with Surge Supressor.Make: ABB-AF 190-40-11-14 +CAL 9-11, Schneider/Siemens."

60

26288

1577280

... More
"Supply of Contactor for 60KVA Transformer, Voltage :415V AC, Current-200A, Pole: 4NO, with 1NO+1NC, control Voltage: 168-300V AC with Surge Supressor. Make: ABB-AF 140-40-00- 13 +CAL 9-11, Schneider/Siemens."

60

26288

1577280

... More
Supply of MPCB for ventilation fan unit, Current rating : 3-4 A, Thermal release range: 2.5-4 A, Class: 10,Breaking Capacity: 10kA, Pole: 3, Voltage: 415 V AC,1NO+1NC auxiliary contact block Make: Legrand, cat No. (002807+002817)/ABB Cat No- (MS116-2.5, HK1-11)/Siemens/Schneider

150

3213

481950

... More
"Supply of MPCB for compressor unit, Current rating: 16 A,Thermal release range: 10- 16 A, Class: 10, Breaking Capacity: 10kA, Pole: 3 P, Voltage Rating: 415 V AC. Make: ABB,Cat NoMS116-16/ Legrand cat no-002811/ Siemens/Schneider."

150

7828

1174200

... More
Supply of MPCB for condenser fan unit 1.1,Current rating : 2.5 A, Thermal release range: 1.6-2.5 A, Class: 10 ,Breaking Capacity: 10kA,Pole: 3, Voltage: 415 V AC. Make: ABB, Cat No- MS116-2.5/ Legrand cat no002806/ Siemens/Schneider

100

3213

321300

... More
Supply of new SS "spider" for condenser motor similar as fitted in LHB type RMPU as per site requirement

15

3127

46905

... More
Removal of defective/ broken Spider & erection, testing and commissioning of new SS spider for LHB type RMPU.(Defective to be returned to consignee store) 93

15

2301

34515

... More
Supply of new suction Accumulator for LHB type RMPU.

25

3540

88500

... More
Removal of defective" accumulator" & re-fitment with new one Including drier. (All types of gas ,system flashing with N2, leak test as per SMI, Vacuum pump reqd. will be supplied by firm). Defective Compressor to be deposited to consignee store).

25

7080

177000

... More
Supply of NTC temperature sensor (rated capacity 5K) with connector for RA/FA/SA for LHB RMPU

500

2950

1475000

... More
Removal & replacement of Defective/damaged NTC temp. sensor with Connector by new NTC temp.sensor for LHB RMPU. ( Defective NTC to be deposited to consignee store) 97

500

885

442500

... More
Supply of rotary switch (16A,7 Pole,3 Position {Auto,manual & OFF}) for LHB RMPU

20

3392

67850

... More
Removal & replacement of Defective/damaged rotary switch (16A,7 Pole,3 Positon) with new similar rotary switch for LHB RMPU. Defective to be deposited to consignee store) 99

20

1770

35400

... More
Supply of 2A,1.2 Ky AC fuse(Make -SIBA). Fuse size: 8mmx50mm for LHB RMPU

500

1180

590000

... More
Supply of 125A,NH-1L type, 120KA 1000V AC HRC fuse for LHB Coaches (Make- siba,E.T.N Busmann or similar).

500

3245

1622500

... More
Supply of refrigerant gas R-407C(45/47 KG/ cylinder) without cylinder, (i.e; Empty Cylinder will be returned after consumption of the gas) [Set=Cylinder]

30

66552

1996560

... More
Supply of refrigerant gas R-22(45/47 KG/cylinder) without cylinder. (i.e; Empty Cylinder will be returned after consumption of the gas) [Set=Cylinder] 103

20

69030

1380600

... More
Supply of manual valve 1/2" for LHB RMPU.

20

6785

135700

... More
Supply of MCB( triple pole) 20A, C-Curve,415 V AC for compressor motor. Make- Legrand-DX3-C20 or Similar.

100

1015

101500

... More
Supply of MCB for Heater with auxiliary contact block. Thermal release range ,Rated Current: 16 A,C-Curve, Breaking Capacity: 10kA,Pole:3 P, Rated Voltage: 415 V AC.Make-Siemens- 5SL43167RC+5ST3010 or ABB-SB203 M-C16 or similar 107

100

1057

105700

... More
Supply of MPCB with NO+NC auxiliary for water pump(1 to 1.6 Amp.) 108

25

3540

88500

... More
Supply of MPCB with NO+NC auxiliary for Exhaust fan(0.1 to 2.5 Amp.) 109

25

4425

110625

... More
Supply of MCB (double pole)10A, C Curve for light control circuit.

100

637

63700

... More
Supply of MCB (double pole)6A, C-Curve for diagnosis circuit,AC compact control and pump control circuit. light control circuit 111

100

637

63700

... More
Supply of MCB (double pole)16A,C-Curve for DC /DC converter related circuit

100

1180

118000

... More
"Supply of Selector of power supply (ON/OFF) Switch, with NO+NC Auxiliary contactor- Make-Siemens 3SB50002ABO1+3SB 54000E, L&T- EMNCSK1+ECIC, or XB5AD21N+ZBE101N +ZBE102NSchneider or similar. "

100

885

88500

... More
Supply of Feeder selection Rotary switch with marking"I-0-II"net1-Local main supply- 113 net 2(Change over switch with 0-position 3-pole) Rated votage 690 V AC Rated current 16 A.Make- Siemens-3SBS000-2D801+3SB5400-0A or L & T- 61069SCB03TDY or SCHNEIDER- XB5AD33N+ZBE101N+ZBE102NN or similar.

100

1180

118000

... More
Supply & replacement of new muitifunctional monitoring relay for 3 phase main 114 suitable for 400/480V AC +/-15%,50-60 HZ, Control 300-500 V AC system, monitoring phase parameter ,phase sequence, phase failure, over and under voltage and phase unballanced (make- ABB,type-CM-MPS 41S or SIEMENS-7UGOB18-1CA20 or M's Carlo Gavazzi-DPCO1DMA8 400/480 or similar

300

5133

1539900

... More
"Supply of MCB for RBC cum EBC Rated Current: 25 A, Curve: D Rated Votage: 415 V AC, Pole: 3P, Breaking Capacity: 10 kA, Make-Siemens- 5SL73258RC or ABB-SB203 M-D25 or L&T- BB30250D or similar. "

50

1057

52850

... More
"Supply of MCB for EBC, Rated Current: 20 A, Curve: C, Rated Voltage: 415 V AC,Pole: 2 P Make-Siemens-5SL42207RC or ABB-SB202M-C20 or L&T-BB20200C or Schneider-A9N2P20C or similar"

50

637

31850

... More
Supply of MCB for 5 KVA transfomer (primary) Rated Current: 16 A, Curve: D Rated Voltage: 415 V AC Pole: 3 P, Breaking Capacity: 10 kA. Make-ABB-SB203 M-D16 or Siemens- SL73168RC or Schneider- A9N3P16D or similar

60

1057

63420

... More
Supply of MCB for 5 KVA transformer(secondary) for mobile/laptop charging circuit, Rated Current: 25 A, Curve: C, Rated Voltage: 230 V AC, Pole: 4 P, Breaking Capacity: 10 kA. Make- ABB-SB204 M-C25 OR Siemens-5SL73168 RC or L&T-BB3016OD or similar

60

1387

83220



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.