East Central Railway Tender

With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

East Central Railway - ECR Tender

Works
Electrical and Electronics
Ireps
Opening Date3 Jan 2025
Closing Date24 Jan 2025
Tender Amount₹ 1,94,88,799.68 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of FRP type TLJB(track lead junction box) fitted with 4-way ARA terminals with 4 Angle iron of Size (1500 x 50 x 50)mm & 6mm thick to hold the junction box and for fixing cable entry pipe (40x 500) mm. as per Spec.No.- RDSO/SPN/151/1997or latest. (ARA terminal Inspection- RDSO, TLJB-Inspection Consignee) 5

80

789

63188

... More
Installation of Track Lead Junction Box as per direction of site engineer

80

319

25574.4

... More
Supply of point JB fitted with 18 Nos. 1 way ARA PBT terminal block conforming to IRS - 6 S- 75/91 with 3 Nos. of 40mm Bore. GI pipe 600 mm long as per DRG No. SGW/MGS/ PT4/91 fixed on hard wood plank with U-channel (75 x 40 x 1500) mm for fixing. INSPECTION: Consignee, ARA PBT Terminals - RDSO.

80

3854

308324.86

... More
Transpotation of materials by 15 MT Capacity Truck as per direction of site incharge..

-

-

8

... More
Supply of clamp type track device (Axle counter) as per RDSO Specification no. RDSO/ SPN/ 177/ 2012Version 3.0 or Latest of 21 KHz/ 25KHz suitable for GG Tronics make. Inspection- RDSO

-

-

1390945

... More
Supply of Tag Blocks 200/160/120 way with polycarbonate cover as per IRS S 77- 10 2006(Rev.1) RDSO DRG. No. SA 24751, SA 24752 & SA 24753. Requirement of each type shall be specified by Engineer-in-charge. Note- Material should be supplied along with Test certificate from OEM and his warranty certificate. Before supply, sample must be approved by consignee & controlling officer (INSPECTION: CONSIGNEE)

80

1296

103716

... More
Supply of Tag Blocks 96/100 way with polycarbonate cover as per IRS S 77- 11 2006(Rev.1) Requirement of each type shall be specified by Engineer-incharge.Note- Material should be supplied along with Test certificate from OEM and his warranty certificate. Before supply, sample must be approved by consignee & controlling officer (INSPECTION: CONSIGNEE)

80

1371

109737.6

... More
Transportation of less heavy material & man power supply & running of one muv to the 12 sites of work as per requirement & direction of engineer in charge along with driver. The rate includes all taxes ,license fee, road permit, driver wages, fuel, repair, & maintenance cost etc complete in all respects.

6000

21

129720

... More
Supply, Installation and Commissioning of rail head continuity bond by pinbrazing as per RDSO Spn no. IRS: 103-2004 with latest amendment. as per technical specification attached. (INSPECTION: CONSIGNEE)

200

1800

360000

... More
Supply, Installation and Commissioning of TLJB lead wire bond( 20 sq. mm. 2.5 mtrs long) by pinbrazing as per RDSO Spn no. IRS: 103-2004 with latest amendment. as per technical specification attached. (INSPECTION: CONSIGNEE)

200

1600

320000

... More
Supply, Installation and Commissioning of TLJB lead wire bond ( 4.5 mtrs long) by pinbrazing as per RDSO Spn no. IRS: 103-2004 with latest amendment.as per technical specification attached.. (INSPECTION: CONSIGNEE)

200

1900

380000

... More
Supply of Pre-fabricated signalling housing having outer dimension of 3000x3000x3080 mm made of 80 mm thick polyurethane foam sandwich panel for equipment/Relay room complete with doors electrometric water proffing, ventilators, exhaust fans etc. sun/rain guard, 16 PVC flooring, Twin tube lights, fans etc. Manufacturers test and guarantee certificate to be submitted by the contractor. This also includes execavation of trenches for foundation and construction of foundation as per fabricated building with all accessories supplied in items above on the foundation erected. All materials including cement and steel to be supplied by the contractor. Double locking arrangement to be provided in the door of relay room. (INSPECTION: CONSIGNEE)

2

310256

620512.2

... More
Supply, installation and commissioing of Fuse auto change over system Type-I along with audio and visual indiation as per RDSOspec. no. RDSO/SPN/209/2012 ver 1.0 or latest. One 17 module off use alarm system should be able to cater for monitoring of 32 nos of "G" type or any other type off use 0.6 amp to 4 amp.Inspection by RDSO. Installation and commissioing of the FuseAuto changeover system Type-I along with supply of accessories i.e . Wires , terminals as per site requirement. Inspection- RDSO

40

28279

1131184.8

... More
Supply & Installation of Integrated multiplexer having FXO/FXS, Ethernet and E & M port (Specification to be complied as per Annexure-A) and special conditions as per Annexure-B. MODEL TEAM LINK TANSY Inspection- RITES

8

466100

3728800

... More
Supply installation, testing & commissioning of Data Logger System for Rly S&T. Installation as per RDSO Specification no. lRS:S:99/2006 with latest amendment with 2048 Digital input and 96 Analog inputs with, Dot matrix printer. Inspection - RDSO

2

700496

1400992.04

... More
"Supply and installation of modular power supply arrangement for VDU (42""- 85"") and embedded PC with input and output redundancy arrangement and hot pluggable modules having voltage & load current digital display on each module. Each set consisting of: - 1. Isolated inverters (master/slave with auto changeover) -2 Nos. input: 110VDC, output: 110 VAC, 500VA (as per RDSO TAN No. STS/E/TAN/3012 Version 3.0 Dated.03.11.22) 2. Isolated DC-DC converters - 02 Nos. connected in parallel with built in O-ring diode, active current sharing as per RDSO/SPN/165/2023 version 4.0 or latest (input: 110VDC, output:24 VDC/10A) 3. Input (redundancy) O-ring diode module with two input sources and one output supply along with potential free contacts, alarm and acknowledgment switch. 4. 3U stainless steel rack with back panel mother board and front panel power connectors, power cord for VDU panel. Make : Gallant or Similar Offered/Accepted Make M/S GALLANT POWER CONVERSION PVT.LTD./BENGALURU Inspection- RDSO"

6

230100

1380600

... More
Supply of Professional large format smart 4K LED display unit size 65" display 21 resolution 3840X2160,450 nits(UHD) including all fixing accessories with installation ,(port) USB/LAN/HDMI/VUA/Video out.Make-65XT800 ULTRA HD 4K UHD LED DISPLAY or similar. (INSPECTION: CONSIGNEE)

3

182661

547983.54

... More
Supply of Microcontroller based programmable static switching module of naturally air 22 cooled only with an at a glance LCD display suitable for break-less switching between two DC supplies of UP to 40A for 20-110VDC. Note-Technical compliance of OEM along with Make & Model certificate as per attached format must be submitted with offer. (INSPECTION: RITES)

20

82600

1652000

... More
Supply of Diagonistic tool for Datalogger having specs Intel Dual core i5 Motherboard 23 1TB SATA HDD 8GB RAM COMBO DRIVE,21" TFT Monitor 10/100/1000 LAN CARD win XPP,Norten Anti Virus, Key Board, Optical Mouse, USB, Serial, Parrallol Port with JBL SPEAKER, 56 KBPS INTERNAL MODEM, WINDOWS 10 HOME VERSION WITH RECOVERY CD, ALONG WITH 500 VA UPS with HP Laser Jet A4 Printer Model No. 1020 or, Similar (INSPECTION: RITES)

22

94683

2083040.52

... More
"Installation, Erection & Wiring of CLS unit, Post, Ladder & Base, LED unit including paying out of tail cable from location box & earthing of CLS (LED type). This includes supply of non- metallic (FRP) colour light signal housing multi-unit type for Rly. signalling, suitable for RE area, 3 24 aspect complete without lenses, lamps and signal transformer as per drg. no. SA23002/A/M/ ADV. ALT-8 and per spec. no. RDSO/SPN/194/2006 (VER- 1.0) or latest and FRP material as RDSO spec. no. RDSO/SPN/ 151/ 1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note:- Signal should be compatible to 'LED' type. Inspection:- RDSO Note:- Installation, Erection & Wiring of signalling unit includes LED signal litghtening unit including Curretnt Regulator & Health Monitoring unit. This also includes protection of unit from rain water."

-

-

347189.59

... More
"Installation, Erection & Wiring of CLS unit, Post, Ladder & Base, LED unit including paying out of tail cable from location box & earthing of CLS (LED type). This includes supply of non- metallic (FRP) colour light signal housing multi-unit type for Rly. signalling, suitable for RE area, 2 25 aspect complete without lenses, lamps and signal transformer as per drg. no. SA23003/A/M/ADV.ALT- 8 and per spec. no. RDSO/SPN/194/2006 (VER- 1.0) or latest and FRP material as RDSO spec. no. RDSO/SPN/ 151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note:- Signal should be compatible to 'LED' type. Inspection:- RDSONote:- Installation, Erection & Wiring of signalling unit includes LED signal litghtening unit including Curretnt Regulator & Health Monitoring unit. This also includes protection of unit from rain water."

-

-

324456.62

... More
"Installation, Erection and wiring of Junction Type Route Indiator (LED type). This includes supply of non- metallic (FRP) Junction Type Route Indiator for Rly signalling suitable for RE area without lamp, lenses, signal transformer as per RDSO spec. no. RDSO/SPN/194/2006 (VER-1.0) or 26 latest. FRP material as per RDSO SPEWC no. RDSO/SPN/151/1997 or latest. All drawings should be as per latest. Material to be procured from RDSO's approved firm only. Note:- Signal unit should be compatible to 'LED' type, Inspection - RDSO Note:- Installation, Erection & Wiring of signalling unit includes LED signal litghtening unit including Current Regulator & Health Monitoring unit. This also includes protection of unit from rain water."

-

-

949755.02

... More
Provision of Misc. S&T items required for installation of DLMC room at BJU. The detail is as below:-

-

-

919300.89



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.