East Central Railway Tender

With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.

East Central Railway - ECR Tender

Works
Civil And Construction
Construction Material
Electrical and Electronics
Metals and Non-Metals
Electrical Works
Ireps
Opening Date14 Jan 2025
Closing Date7 Feb 2025
Tender Amount₹ 36,74,68,763.31 
Notes
Download

Costs

Summary

Supply, Erection, Testing, Commissioning For Construction Of 132kv , 2 Phase , Double Circuit Transmission Line From Grid Substation (gss) Laukahi To Railway Tss Laukahabazar

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Tower Earthing (a) Pipe Type 5

130

11162

1451139.3

... More
Danger plate 6

130

526

68441.1

... More
Number plate 7

130

526

68441.1

... More
Phase plate (set of three) 8

260

409

106568.8

... More
Circuit Plate (set of two) 9

130

409

53284.4

... More
Bird Guard (set of three) 10

260

2910

756839.2

... More
Anti-Climbing Device

130

12318

1601421.9

... More
ACSR Panther Conductor 12

-

-

11

... More
Long Rod Polymer Insulator 90 KN of light weight 13

552

6474

3574039.92

... More
Long Rod Polymer Insulator 70 KN of light weight 14

292

6035

1762328.04

... More
Single 'I' Suspension Fittings 15

228

3904

890328.6

... More
Double Suspension Fittings 16

32

8046

257496

... More
Single Tension Fittings 17

488

4151

2025990.56

... More
Double Tension Fittings 18

32

8646

276699.2

... More
Mid Span compression joint for ACSR Panther conductor 19

35

1121

39258.1

... More
Repair sleeve for ACSR Panther conductor 20

35

466

16321.9

... More
Vibration Damper for ACSR Panther conductor 21

1560

1162

1812969.6

... More
PA Rod (Complete set) for conductor 22

260

1559

405540.2

... More
24 Fiber (DWSM) OPGW Fiber Optic Cable 23

36.75

223581

8216605.79

... More
Hardware set for OPGW CABLE

36

45667

1644040.44

... More
2/3/4 way Joint Box (24 Fiber) including Coiling bracket as per requirement for looping/coiling of 30 meters of cable as per technical requirement 25

9

37030

333276.84

... More
Supply of HTLS Conductor Capacity -240MVA,1050 A (Equivalent to Panther )

20

1152100

23042000

... More
Complete Tower Erection of various types of towers including M/C tower (if applicable) including stub setting, tack welding up to the cross arm, fixing of hangers of 20 mm rod, U-bolt etc. complete in all respect as per Specification & requirement. 2

640

19224

12303718.4

... More
Tower Earthing-Pipe Type 3

130

6254

813020

... More
Danger plate 4

130

129

16874

... More
Number plate 5

130

129

16874

... More
Phase plate (set of three) 6

260

129

33748

... More
Circuit Plate (set of two) 7

130

129

16874

... More
Bird Guard (set of three) 8

260

389

101244

... More
Anti-Climbing Device

130

2478

322140

... More
STRINGING of 132 KV D/C transmission line with with 04 Phase ACSR Panther Conductor (without OPGW/ Earthwire) complete with all works including stringing of Conductor, Fitting of Hardwares, Hoisting of Insulators etc.

35

210917

7382127.2

... More
Installation/Stringing of 24 F OPGW CABLE complete with all works excluding hardware assemblies and joint boxes (Rate per route KM) 11

-

-

10

... More
Installation of Hardware assembly

35

16776

587162.1

... More
Installation of 2/3/4 way 24 F Joint Box including Coiling bracket as per requirement for looping/coiling of 30 meters of cable

9

51472

463255.02

... More
"Cost Towards Crop Compensation & Tree Cutting & Compensation, PTCC Clearance, All Statuatory Clearances, NH/SH/Road Crossing or Any Other Crossing etc. (except Railway Crossing * 13 & Forest Clearances**) required for successful commissioning of the complete line in all respect. ** All the activity related to Forest Clearances shall be the responsibility of bidders/contractor. The payments towards Forest Department for the forest clearances shall be reimbursed to the bidder/contractor against documentary evidence. "

35

746350

26122250

... More
Detailed complete survey works including preliminary survey, profiling, tower spotting & check survey, submission of survey sheets. (Rate per route KM)

10

37388

373883

... More
Excavation of wet soil 2

5000

261

1305150

... More
Setting of stub including fitting of templates 3

130

16014

2081911

... More
Concerting (1:1.5:3) mixture including cost of cement and RCC

5000

12319

61595000

... More
Circuit Breaker (3 phase) : 1250 A, 31.5 kA SF 6 CB with support structure, marshalling boxes, terminal connectors etc.(current rating shall be equial to the current rating for which the short cuircuit test reports shall be furnished.) (Spring- Spring )

2

1128664

2257328.86

... More
ISOLATORS (3 phase), with solid core insulators, marshaling boxes, terminal connectors (Motor Operated) with moving contact of HDEC copper only :1250 A, 31.5 kA with one earth switch (Double break Isolator)

2

426861

853723.76

... More
ISOLATORS (3 phase), with solid core insulators, marshaling boxes, terminal connectors (Motor Operated) with moving contact of HDEC copper only : 1250 A, 31.5 kA without earth switch (Double break Isolator)(Tandem arrangement)

4

326517

1306069.68

... More
ISOLATORS (3 phase), with solid core insulators, marshaling boxes, terminal connectors (Motor Operated) with moving contact of HDEC copper only : 1600 A 31.5 kA without earth switch ( Double break high level beam mounted insulator)

1

373675

373675.04

... More
CURRENT TRANSFORMER 5 Core (1 phase) WITH MARSHALING BOXES TERMINAL CONNECTORS (The windings of CT shall be of Copper only): 1200 -600-300-150/1-1-1-1-1 A, 5 core 0.2 class ,31.5 kA with 120% extended current rating with marshalling boxes, terminal connectors etc. 6

6

394509

2367055.26

... More
8800 pF CVTs (1 phase) with marshalling boxes, terminal connectors etc .

6

310122

1860732.18

... More
"120 kV Surge arresters class-III ( 1 phase) with marshalling boxes, terminal connectors etc."

6

60055

360332.94

... More
Insulator strings antifog type & hardware, spacers, conductor (S), Bus bar material, 8 cable trays, bay MB, Clamps, Connectors including, Junction box,PVC pipes for equipment and lighting, all accessories etc. for the following (main bus shall be of double Moose conductor and transfer bus shall be strung with sigle Moose conductor) : Line bay

2

844988

1689977.12

... More
Insulator strings antifog type & hardware, spacers, conductor (S), Bus bar material, 9 cable trays, bay MB, Clamps, Connectors including, Junction box,PVC pipes for equipment and lighting, all accessories etc. for the following (main bus shall be of double Moose conductor and transfer bus shall be strung with sigle Moose conductor) : Bus for two bays (one set includes for Main bus & Transfer Bus) 10

2

56758

113516

... More
132 kV Solid Core, Bus post Insulators for erection hardware

40

15201

608053.2

... More
CONTROL & RELAY PANELS : 132 KV line (with A/R) with numerical distance protection 11 relays and earth fault / overcurrent relays complying to IEC 61850 Protocal with optical fiber ports sufficient DI/DO for scheme with additional 6 DI/DO for spare. All indicating meters/ multifunctions meters shall be communicable tpe with 0.5 class accuracy 12

2

1378326

2756652

... More
FIRE PROTECTION SYSTEM : Portable Fire Extinguishers-4.5 Kg DCP Type 13

2

8799

17598.04

... More
Portable Fire Extinguishers : 4.5 Kg CO2 Type 14

12323.54

2

24647.08

... More
Portable Fire Extinguishers : 22.5 Kg CO2 type 15

2

31265

62530.74

... More
12 Fire buckets with covered stand 16

2

2265

4530.82

... More
Lighting Panel (Indoor) Type ACP-1 as per Tech. Specification of BSPTCL 17

1

43559

43559.46

... More
Modular switch board with 4 nos. 5Amp. Switches and 1 no. 5/15 Amp. receptacles 18

4

1212

4849.88

... More
Modular switchboard with 1 no. 32 Amp. MCB

2

1363

2726.84

... More
Junction boxes with 4 nos. of terminal blocks for indoor lighting excluding junction box supplied along with lighting fixture 20

1

5475

5475.77

... More
Power cables (XLPE) 1.1 kV : 1C X 150 mm2 21

1

507236

507236.12

... More
Power cables (PVC) 1.1 kV : 3.5C X 70 mm2 22

3

459239

1377717.3

... More
Power cables (PVC) 1.1 kV : 3.5C X 35 mm2 23

1

379865

379865.03

... More
Power cables (PVC) 1.1 kV : 4C X 16 mm2 24

2

213657

427315.94

... More
Power cables (PVC) : 4C X 6 mm2 25

2

140201

280402.92

... More
Power cables (PVC) 1.1 kV : 2C X 6 mm2 26

4

78769

315076.24

... More
Control cable (PVC) 1.1 kV : 2C X 2.5 mm2 27

1

132933

132933.99

... More
Control cable (PVC) 1.1 kV : 3C X 2.5 mm2 28

1.5

170146

255219.55

... More
Control cable (PVC) 1.1 kV : 5C X 2.5 mm2 29

5

252886

1264433.25

... More
Control cable (PVC) 1.1 kV : 7C X 2.5 mm2 30

1.5

324801

487202.7

... More
Control cable (PVC) 1.1 kV : 10C X 2.5 mm2 31

3

431158

1293474.93

... More
Control cable (PVC) 1.1 kV : 14C X 2.5 mm2 32

4

603065

2412262.88

... More
Control cable (PVC) 1.1 kV : 19C X 2.5 mm2

1

792439

792439.86

... More
Control cable (PVC) 1.1 kV : 27C X 2.5 mm2 34

-

-

33

... More
40 mm MS rod for main earth mat 35

30

121781

3653435.7

... More
75x12 mm G.I Flats for risers for equipments, columns and structures 36

10

127432

1274324.5

... More
50x6 mm G.I flats for risers for all other equipments etc.

5

127432

637162.25

... More
Materials for treated earthing pits with supply of all earthing materials including base plate etc. complete in all respect as per Technical Specifications

1

1890329

1890329.79

... More
Sub- Station galvanized Steel structure (132 kV) (SAIL/RINL/TATA or its authorised approved rerollers) : Lattice structure with fasteners etc. (for Gantry, Tower, Beam)

40

133298

5331938.4

... More
Station galvanized Steel structure (132 kV) : Standard structure for equipment support (except CB)

15

133298

1999476.9

... More
Sub- Station galvanized Steel structure (132 kV): Cable Racks as per design requirement for Switchyard and Control room building.

9

141782

1276038.9

... More
Air conditioning of control room with High wall type 5 star Invertor Split Air conditioner (BEE Complied) Units of 2 TR capacity with 5KVA stablizer and required accessories. 42

5

74506

372534.95

... More
wall mounted fans 400mm sweep 43

5

3232

16162.2

... More
1400mm sweep with electronic step regulator 44

5

3282

16413.8

... More
Ehaust fans

4

5110

20440.24

... More
Sub- Station automation system comprising of necessary equipments & materials wth 45 networking and interfacing, complete in all respect (Break up of item to be given by contractor in technical data sheet with Part-I of the tender) whereever applicable, the communication protocol shall be preferably IEC 61850 (Edition-2).

1

1227200

1227200

... More
Overhead shielding gainst lightning by galvanized steel wires and fittings as per requirement

1

105533

105533.06

... More
1250 A, 31.5 kA SF 6 CB with support structure, marshalling boxes, terminal connectors etc.(current rating shall be equial to the current rating for which the short cuircuit test reports shall be furnished.) (Spring- Spring )

2

17886

35772.88

... More
ISOLATORS (3 phase), with solid core insulators, marshaling boxes, terminal connectors (Motor Operated) with moving contact of HDEC copper only : 1250 A, 31.5 kA with one earth switch (Double break Isolator)

2

17043

34087.84

... More
ISOLATORS (3 phase), with solid core insulators, marshaling boxes, terminal connectors (Motor Operated) with moving contact of HDEC copper only : "1250 A, 31.5 kA without earth switch (Double break Isolator)(Tandem arrangement)"

4

16463

65853.44

... More
"ISOLATORS (3 phase), with solid core insulators, marshaling boxes, terminal connectors (Motor Operated) with moving contact of HDEC copper only" : 1600 A 31.5 kA without earth switch ( Double break high level beam mounted insulator)

1

16463

16463.36

... More
CURRENT TRANSFORMER 5 Core (1 phase) WITH MARSHALING BOXES TERMINAL CONNECTORS (The windings of CT shall be of Copper only) : "1200 -600-300-150/1-1-1-1-1 A, 5 core 0.2 class ,31.5 kA with 120% extended current rating with marshalling boxes, terminal connectors etc." 6

-

-

5

... More
8800 pF CVTs (1 phase) with marshalling boxes, terminal connectors etc .

6

4617

27704.04

... More
"120 kV Surge arresters class-III ( 1 phase) with marshalling boxes, terminal connectors etc." 8

6

1621

9727.92

... More
ERECTION HARDWARE (132 kV) : Line bay

2

85165

170330.64

... More
ERECTION HARDWARE (132 kV) ; "Bus for two bays (one set includes for Main bus & Transfer Bus)" 10

2

2862

5725.36

... More
132 kV Solid Core, Bus post Insulators for erection hardware

40

733

29358.4

... More
CONTROL & RELAY PANELS : "132 KV line (with A/R) with numerical distance protection 11 relays and earth fault / overcurrent relays complying to IEC 61850 Protocal with optical fiber ports sufficient DI/DO for scheme with additional 6 DI/DO for spare. All indicating meters/ multifunctions meters shall be communicable tpe with 0.5 class accuracy"

2

7085

14171.8

... More
Air conditioning of control room with High wall type 5 star Invertor Split Air conditioner 12 (BEE Complied) Units of 2 TR capacity with 5KVA stablizer and required accessories i.e. Power plug, socket, MCB, wires etc. (The quantity mentioned is tentative, which will be decided during detailed engineering based on heat load calculation) 13

5

7864

39323.5

... More
Portable Fire Extinguishers : 4.5 Kg DCP Type 14

2

533

1066.72

... More
Portable Fire Extinguishers : 4.5 Kg CO2 Type 15

2

533

1066.72

... More
Portable Fire Extinguishers : 22.5 Kg CO2 type 16

2

997

1994.2

... More
12 Fire buckets with covered stand 17

2

81

162.84

... More
Lighting Panel (Indoor) Type ACP-1 as per Tech. Specification 18

1

3390

3390.14

... More
Modular switch board with 4 nos. 5Amp. Switches and 1 no. 5/15 Amp. receptacles 19

4

191

764.64

... More
Modular switchboard with 1 no. 32 Amp. MCB

2

354

708

... More
Heavy duty PVC conduits as of 20/25/32 mm size complete with all accessories for 20 point wiring for Light points, Fans power points 5/15 amps. With 2.5 sq.mm/4 mm2/6.0 mm2 copper for circuit wiring and 1.5 mm2 copper earth wire PVC insulated in green color including wiring for submains i.e. wiring from Lighting panel to switch board.

1

94294

94294.98

... More
Wiring from lighting panel to switch boards, from switchboard to junction boxes for light points with 2.5/4.0/6.0 mm2 copper wire as per technical specification, complete in all respect. 1.5 mm2 copper wire (green) will be used for earthing inside conduits 22

1

77017

77017.42

... More
Ceiling fans 1400 mm sweep with electronic step regulator 23

5

341

1705.1

... More
Exhaust fans (300 mm dia with dampers) 24

4

598

2393.04

... More
Wall mounted fans 400 mm sweep 25

5

341

1705.1

... More
Lighting panel (Outdoor) Type ACP - 2

1

3390

3390.14

... More
Power cables (XLPE) 1.1 kV : 1C X 150 mm2 27

1

32091

32091.28

... More
Power cables (PVC) 1.1 kV : 3.5C X 70 mm2 28

3

46154

138463.56

... More
Power cables (PVC) 1.1 kV : 3.5C X 35 mm2 29

1

36682

36682.66

... More
Power cables (PVC) 1.1 kV 4C X 16 mm2 30

2

30296

60593

... More
Power cables (PVC) 1.1 kV 4C X 6 mm2 31

2

24569

49139.92

... More
Power cables (PVC) 1.1 kV 2C X 6 mm2 32

4

14767

59070.8

... More
Control cable (PVC) 1.1 kV 2C X 2.5 mm2 33

1

24910

24910.98

... More
Control cable (PVC) 1.1 kV 3C X 2.5 mm2 34

1.5

29077

43616.34

... More
Control cable (PVC) 1.1 kV 5C X 2.5 mm2 35

5

32711

163559.8

... More
Control cable (PVC) 1.1 kV 7C X 2.5 mm2 36

1.5

36375

54563.79

... More
Control cable (PVC) 1.1 kV 10C X 2.5 mm2 37

3

39980

119942.28

... More
Control cable (PVC) 1.1 kV 14C X 2.5 mm2 38

8

45433

363468.32

... More
Control cable (PVC) 1.1 kV 19C X 2.5 mm2 39

1

45433

45433.54

... More
Control cable (PVC) 1.1 kV 27C X 2.5 mm2 40

6

49067

294407.64

... More
40 mm MS rod for main earth mat 41

30

6544

196328.4

... More
75x12 mm G.I Flats for risers for equipments, columns and structures 42

10

7490

74906.4

... More
50x6 mm G.I flats for risers for all other equipments etc.

5

14219

71095

... More
Materials for treated earthing pits with supply of all earthing materials including base plate etc. complete in all respect as per Technical Specifications 44

1

232988

232988.64

... More
Lattice structure with fasteners etc. (for Gantry, Tower, Beam) 45

40

3843

153730.4

... More
Standard structure for equipment support (except CB) 46

15

3843

57648.9

... More
Cable Racks as per design requirement for Switchyard and Control room building.

9

4730

42575.58

... More
Sub- Station automation system comprising of necessary equipments & materials wth 47 networking and interfacing, complete in all respect (Break up of item to be given by contractor in technical data sheet with Part-I of the tender) whereever applicable, the communication protocol shall be preferably IEC 61850 (Edition-2).

1

295000

295000

... More
Overhead shielding against lightning by galvanized steel wires and fittings as per requirement and design (excluding lighting cum lightning mast)- If required during detailed engineering

1

6707

6707.12

... More
Excavation of wet soil

400

261

104412

... More
Concereting (1:1.5:3) mixture including cost of cement and RCC work 3

-

-

2

... More
Supply & spreading of Ballast/Gravel in the switch Yard.

100

3048

304800

... More
SDH equipment (STM-4 MADM, upto 5 MSP protected direction) :direction) Base 1 Equipment (Common cards, Cross Connect/control cards, optical base cards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipped excluding (2) & (3) below 2

2

1625000

3250000

... More
Optical Interface Cards/SFP# : S4.1 SFP 2

8

36400

291200

... More
L4.1 SFP 2

4

54600

218400

... More
L4.2 SFP 3

4

84500

338000

... More
Tributary cards : E1 Interface card (Min.16 interfaces per card) 3

2

244400

488800

... More
Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) 3

2

400400

800800

... More
Equipment cabinet 4

4

114400

457600

... More
Hardware/Software 4

2

223600

447200

... More
FODP (48 Fibre) Indoor/Outdoor type 5

2

234000

468000

... More
Approach cable (24 fibre) including all installation Hardware Set (with HDPE) 6

2

247000

494000

... More
Patch cords

2

3640

7280

... More
Digital Protection Coupler suitable for integration and operation through OPGW System with required Cables, complete in all respect.

4

832000

3328000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.