All India Institute Of Medical Sciences Tender
With BidAssist, you can search for multiple business options for RWD Bihar tenders, RCD Bihar tenders, and any other e tender Bihar government is inviting bids for. Such Bihar tenders are posted on the eprocurement Bihar website, and on this page, you will get consolidated lists of Bihar tenders that can be sorted based on authority, department, city, and more.
Costs
EMD
₹ 1,19,308Document Cost
₹ 1,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_AMSPA_841530_1Tender No
AIIMS/Pat/SE/138/125849Tender Authority
All India Institute Of Medical Sciences ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
MASONRY WORK Providing and laying Autoclaved Aerated Concrete (AAC) blocks masonry 100 mm / 125mm thick with Grade 1 AAC blocks of density 551 to 650 kg/cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
4.83
-
-
... More
CLADDING WORK Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
51.56
-
-
... More
WOOD AND P. V. C. WORK Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm
12
-
-
... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm
4
-
-
... More
Providing and fixing factory made uPVC glazed/ wire mesh windows/ doors comprising of lead free uPVC multi- chambered frame, sash and mullion/ coupler (wherever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia. with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/ mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh/ Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (iii) Sites with basic wind speed 45 m/sec as per IS 875 - Part 3 (iv) Sites with structure height more than 20m for all wind speeds. Three track three panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (98mm & above) x (40mm & above) & sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on two end panels along with multi-point locking system (Height upto 1.8 meter).
17.6
-
-
... More
FLOORING Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
14.92
-
-
... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
132.9
-
-
... More
ROOFING Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m²
46
-
-
... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
30
-
-
... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
146.33
-
-
... More
FINISHING Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
186
-
-
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
34.87
-
-
... More
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
186
-
-
... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
186
-
-
... More
SANITARY INSTALLATIONS Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required: White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests
1
-
-
... More
Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
1
-
-
... More
Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mmsizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clampscomplete, including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern
1
-
-
... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever require: White Vitreous China Angle back wash basin size 600 x480 mm with single 15mm C.P. brass pillar tap
2
-
-
... More
Providing and fixing white vitreous china pedestal for wash basincompletely recessed at the back for the reception of pipes andfittings.
2
-
-
... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto1 metre long with S.S. triangular plate to Eureopean type W.C. ofquality and make as approved by Engineer - in - charge.
2
-
-
... More
Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. Semi rigid pipe 40 mm dia
2
-
-
... More
Providing and fixing mirror of superior glass (of approved quality) andof required shape and size with plastic moulded frame of approvedmake and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm
2
-
-
... More
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved qualityand colour, weighing not less than 105 gms.
2
-
-
... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,200 mm wide with minimum distances of 37 mm from wall face withconcealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.
2
-
-
... More
WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls 20 mm nominal dia Pipes
20
-
-
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls 32 mm nominal dia Pipes
30
-
-
... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore
1
-
-
... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
2
-
-
... More
Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
7
-
-
... More
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length
7
-
-
... More
ALUMINIUM WORK Supply and fixing of 50/85mm thick PUF insulated panels having 40+2 Kg/m3 density lined with pre coated GI sheet bothsides. The pre-coated sheet shall be of minimum 240mpa steel grade confirming IS 14246:1995 and shall have zinc coating of minimum 120gsm as per IS 277: 1922, 5-7 microns epoxy primer on both side of the site and polyester topcoat 15-18 micron. The PPGI sheet shall have plastic protective guard film of minimum 25 microns to avoid scratches during transportation. The top sheet of these panels shall be in trapezoidal shape. These panels shall have overlap joinery system. The polyurethane will be conforming to IS 12436-1988 and flammability as per 52 DUN 4120 part 1. The PU is injected into the panel with a high pressure dispensing uint capable of forming a panel in single shot. The draulic press has oil heated platens which allow smooth flow of PUF chemicals mixture when it is injected for forming of panels.(Incl. Flashings &Hardware')
146.33
-
-
... More
STRUCTURAL GLAZING ALUMMINIUM COMPOSITE PANEL Designing, fabricating, testing, protection, installing and fixing inposition semi (grid) unitized system of structural glazing (with openjoints) for linear as well as curvilinear portions of the building for allheights and all levels, including: (a) Structural analysis & design and preparation of shop drawingsfor the specified design loads conforming to IS 875 part III (thesystem must passed the proof test at 1.5 times design windpressure without any failure), including functional design ofthe aluminum sections for fixing glazing panels of variousthicknesses, aluminium cleats, sleeves and splice plates etc.gaskets, screws, toggles, nuts, bolts, clamps etc., structuraland weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for watertightness, pressure equalisation & drainage and protectionagainst fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised /Aluminium alloy of 6005 T5 brackets of required sizes, sectionsand profiles etc. to accommodate 3 Dimentional movementfor achieving perfect verticality and fixing structural glazingsystem rigidly to the RCC/ masonry/structural steel frameworkof building structure using stainless steel anchor fasteners/bolts, nylon seperator to prevent bimetallic contacts with nutsand washers etc. of stainless steel grade 316, of the requiredcapacity and in required numbers. (c) Providing and filling, two part pump filled, structural siliconesealant and one part weather silicone sealant compatible withthe structural silicone sealant of required bite size in a cleanand controlled factory / work shop environment, including doublesided spacer tape, setting blocks and backer rod, all ofapproved grade, brand and manufacture, as per the approvedsealant design, within and all around the perimeter for holdingglass. (d) Providing and fixing in position flashings of solid aluminiumsheet 1 mm thick and of sizes, shapes and profiles, as requiredas per the site conditions, to seal the gap between the buildingstructure and all its interfaces with curtain glazing to make itwatertight. (e) Making provision for drainage of moisture/ water that entersthe curtain glazing system to make it watertight, byincorporating principles of pressure equalization, providingsuitable gutter profiles at bottom (if required), making necessaryholes of required sizes and of required numbers etc. complete.This item includes cost of all inputs of designing, labour forfabricating and installation of aluminium grid, installation ofglazed units, T&P, scaffolding and other incidental chargesincluding wastages etc., enabling temporary structures andservices, cranes or cradles etc. as described above and asspecified. The item includes the cost of getting all the structuraland functional design including shop drawings checked by astructural designer, dully approved by Engineer-in-charge. Theitem also includes the cost of all mock ups at site, cost of allsamples of the individual components for testing in an approvedlaboratory, field tests on the assembled working structuralglazing as specified, cleaning and protection till the handingover of the building for occupation. In the end, the Contractorshall provide a water tight structural glazing having all theperformance characteristics etc. all complete as required, asper the Architectural drawings, as per item description, asspecified, as per the approved shop drawings and as directedby the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames,shadow boxes, extruded aluminium section capping for fixingin the grooves of the curtain glazing and vermin proof stainlesssteel wire mesh shall be paid for separately under relevantitems under this sub- head. However, for the purpose ofpayment, only the actual area of structural glazing (includingwidth of grooves) on the external face shall be measured insqm. up to two decimal places. Note:-2. The following performance test are to be conductedon structural glazing system if area of structural glazingexceeds 2500 Sqm from the certified laboratoriesaccreditated by NABL(National Accreditation Board forTesting and Calibration Laboratories), Department ofScience & Technologies, India. Cost of testing is payableseparately. The NIT approving authority will decide the necessity of testingon the basis of cost of the work, cost of the test and importanceof the work. Performance Testing of Structural glazing systemTests to be conducted in the NABL accredited lab or any otheraccreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 1. Performance Laboratory Test for Air Leakage Test (-50pato - 300pa) & (+50pa to +300pa) as per ASTM E-283-04testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) asper ASTME- 331-09 testing method for a range up to2000 ml .3. Dynamic Water Penetration (50pa to 1500pa) as perAAMA 501.01- 05 testing method for a range upto2000 ml 4. Structural Performance Deflection and deformation bystatic air pressure test (1.5 times design wind pressurewithout any failure) as per ASTME-330-10 testing methodfor a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as per AAMA501.4-09 testing method for Qualitative test, Tests to beconducted on site.6. Onsite Test for Water Leakage for a pressure range 50kpa to 240 kpa (35psi) upto 2000 ml
36.8
-
-
... More
NEW TECHNOLOGIES AND MATERIALS Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300-550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875-1987, ISO 800-1984 and IS:801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ ArchitekV2.5.16/ Revit architecture-2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple/ slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT. The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.
4812
-
-
... More
Providing and fixing of external wall system on Light gauge steel frame work with outer face cement boards as per standard sizes fixed with self- drilling / taping screws / fasteners @ 60cm c/c of approved make. A groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. The board shall be fixed in a staggered pattern. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. Internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self- drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately) Outer face- Outer face having 6mm thick fiber cement board Type A, Category-III as per IS:14862:2000 fixed on 9mm thick fiber cement board Type A, Category-Ill, as per IS:14862:2000 (high pressure steam cured) Inner Face- 12.5 mm thick gypsum plaster board conforming to IS 2095:2011 fxed on 8 mm thick fibre cement board of Type B, Category-III, conforming to IS:14862:2000 (High pressure steam cured)
129
-
-
... More
Providing and fixing of 4mm thick ACP in panelling fixed in aluminium door, window shutter and partition frames with ss screw etc complete as per aechitectural drawing and direction of engineer-in charge.
45
-
-
... More
Providing and fixing 12 mm thick frameless toughened glass panel of approved brand and manufacture, including providing and fixing all fitting for adjoining glass panels and making necessary holes etc required for fittings, all complete as per direction of Engineer-in-charge
54.9
-
-
... More
Structure design, drawing at all components like column, beams, trusses or any of the item's required at site as per direction of engineer-in-charge ( Structure drawing to be vetted by NIT/ IIT or equivalent government institution) including preparation ogf GFC drawing, shop drawing of fire alarm, Air conditioning system, electrical internal/ external wiring etc as per direction of engineer-in-charge
1
-
-
... More
Electrical work Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface I recessed steel conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
24
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
170
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
345
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
164
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
25
-
-
... More
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group A
23
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
32
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
45
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
60
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
26
-
-
... More
Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
25
-
-
... More
Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
12
-
-
... More
Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (200mmX75mm)
14
-
-
... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
4
-
-
... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
1
-
-
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MOB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
1
-
-
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MOB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
1
-
-
... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required .
(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
1
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
12
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral
2
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
2
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral (63 Amp)
1
-
-
... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and mmissioning etc. as required.
8
-
-
... More
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
40
-
-
... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
4
-
-
... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
100
-
-
... More
Providing and fixing 6 SWG dia GI. wire on surface or in recess for loop earthing as required.
60
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm
40
-
-
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp
200
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 70 sq. mm (38mm)
4
-
-
... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
40
-
-
... More
Supplying Installation,testing, commissioning of online 3 phase UPS System with 30minutes back up including batteries, interconnecting cables, battery racks etc.
5
-
-
... More
SUPPLYING 3.5 C x 70 Sq. mm Al armoured cable XLPE
240
-
-
... More
SITC of 100 AMP MCCB 25KA 4 POLE AT&AM with metallic enclosure and spreader link
2
-
-
... More
SITC of 15/18 W LED Down Light Cool Day 1x1 ft Make:Syska,Havells,Philips.
16
-
-
... More
SITC of 36/40 W LED Down Light Cool Day 2x2 ft Make:Syska,Havells,Philips.
23
-
-
... More
SITC of 18/20 W LED batten Light Cool Day 4 x1 ft Make:Syska,Havells,Philips.
4
-
-
... More
SITC of 300 mm Wall fan
12
-
-
... More
SITC of 300 mm Exhaust fan
4
-
-
... More
25 mm PVC Casing Bit
40
-
-
... More
AC& R Work Supply installation testing and commissioning of 2TR 5 star inverter spli Ac
7
-
-
... More
Copper pipeline with insulation suitable for 2 TR split AC units ( suction & discharge taken in one unit ) dia of pipe - 5/8" & 1/4"
40
-
-
... More
Supplying & fixing drain pipe as per suitable for 2 Tr split AC units
40
-
-
... More
Standard outdoor stand suitable for outdoor units for 2 Tr split AC units
7
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%