Welfare Of Plain Tribes And Backward Classes Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 49,830Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WPTBC_37445_1Bid Award Id
ViewTender No
PTDC/Engg/2023-24/189Tender Authority
Welfare Of Plain Tribes And Backward Classes Department ViewPurchaser Address
-Website
http://https://assamtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
4.1 - Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from
natural sources : 8 graded stone aggregate 20 mm
nominal size derived from natural sources)
4.02
-
-
4.10 - Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
9.06
-
-
5.1 - Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
8.1
-
-
5.2 - Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size
derived from natural sources)
4.92
-
-
5.9 - Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
87.28
-
-
5.9 - Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
31.82
-
-
5.9 - Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
60.67
-
-
6.2 - Brick work with common burnt clay modular bricks of class designation
7.5 in foundation and plinth in:
6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
12.91
-
-
6.8 - Brick work 7 cm thick with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3
coarse sand) in superstructure above plinth level and upto floor five level.
113.92
-
-
11.3 - Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone aggregate
112.15
-
-
11.6 - Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
11.6.1 18 mm thick
21
-
-
13.1 - 12 mm cement plaster: 13.1.1 1:4 (1 cement : 4 fine sand)
164.72
-
-
13.5 - 15 mm cement plaster: 13.5.1 - 1:4 (1 Cement : 4 coarse sand)
224.18
-
-
12.24 - Providing and fixing insulating board ceiling of approved quality with
necessary nails etc. complete (frame work to be paid separately) :
12.24.2 White face insulating board
12.24.2.1 12 mm thick
84.09
-
-
12.1 - Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8
mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets
complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²
229.82
-
-
12.4 - Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I.
limpet and bitumen washers complete.
12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m²
18.6
-
-
12.51 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : 12.51.4 Barge board (Upto 300 mm)
75.03
-
-
13.41 - Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer
173.6
-
-
13.43 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
13.43.1 Water thinnable cement primer
147.62
-
-
13.44 - Finishing walls with water proofing cement paint of required shade :
13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
147.62
-
-
13.52 - Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
13.52.1 On steel work
68.16
-
-
9.63 - Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
9.63.2 200x10 mm
32
-
-
9.62 - Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :
9.62.1 300x16 mm
16
-
-
9.66 - Providing and fixing ISI marked oxidised M.S. handles conforming to
IS:4992 with necessary screws etc. complete :
9.66.1 125 mm
32
-
-
5.22 A - Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
2155.84
-
-
10.16 - Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.3 Electric resistance or induction butt welded tubes
2028.5
-
-
10.14 - Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed
by Engineer-in-charge: 10.14.1 Profile B
10.14.1.1 Fixing with adjustable lugs with split end tail to each jamb
66.4
-
-
10.17 - Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
4
-
-
SSA Assessed Rate: Providing fitting and fixing steel door / window shutter with provision to be fitted MS angle including paint along with khili kabja made out of MS flat of 30 mm x 4 mm thick, minimum 3 nos. for each door leaf and 2 nos for each window leaf. (a) 35 mm x 30 mm x 6mm thick angle for door and 30 mm x 30 mm x 6mm thick for window and MS Sheet thickness 1.25 mm
29.76
-
-
SSA Assessed Rate: Providing fitting and fixing PCC / RCC ready made ventilator
4.2
-
-
10.26 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
10.26.1 M.S. tube
126.42
-
-
11.37 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
140.82
-
-
2.25 (a) - Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and
watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
645.51
-
-
1.3 - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1 .3.1 -Group-A
8
-
-
1.3.2 - Group-B
4
-
-
1.3.3 - Group-C
6
-
-
1.7 - Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/rcessed steel conduit as required. 1.7.1 - 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
132
-
-
1.24 - Supplying and fixing following modular switch/ socket on the
existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 - 5/6 A switch
10
-
-
1.24.2 - 2 way 5/6 A switch
5
-
-
1.24.3 - 15/16 A switch
5
-
-
1.24.4 - 3 pin 5/6 A socket outlet
5
-
-
1.25 - Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
8
-
-
1.27 - Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.3 - 4 Module (125mmX75mm)
12
-
-
1.28 - Supplying and fixing following Modular base & cover plate on existing modular metal box as required. 1.28.6 - 12 Module
7
-
-
2.1 - Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required. 2.1.1 - 32 A TP&N
1
-
-
2.3 - Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volt, on surface/recess cpmlete with tinned copper bus bar, neutral bus bar, eart bar, din bar, inter connections, powder painted including earthing etc. as required.(but excluding MCB/RCCB/Isolator). 2.3.2 - 8 way , Double door
7
-
-
1.13 - Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
31
-
-
2.14 - Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 5.4 - Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1
-
-
5.7 - Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
12
-
-
5.9 - Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
6
-
-
E&M Supplement - Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
5
-
-
2.4 - Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted icluding earthing etc. as required. 2.4.1 - 4 way (4 + 12), Double door
3
-
-
2.4.2 - 6 way (4 + 18), Double door
3
-
-
2.13 - Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.13.1 - 40 A
3
-
-
2.24 - Supplying and fixing Cable End Box (Loose Wire Box) suitable for
following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. 2.24.1 - For 4 way, Double door TPN MCBDB
4
-
-
1.42 - Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
7
-
-
Add 3% yearly premium as per PWD's OM no. B.57/2021/51 dt 03-03-2023 (3%+3%=6%)
1
-
-
Add amount due to enhancement of GST from 12% to 18% as per office memo no. SE/TAS/GST/20 No 158/SE/TAS/GST/2020/331-H dt.10.8.22 @ 6%
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements