BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Welfare Of Plain Tribes And Backward Classes Department - WPTBC Tender
Civil And Construction
Building Construction
Consultancy Services
Civil And Architectural Services
Eprocure
Opening Date2 Jul 2024
Closing Date15 Jul 2024
Tender Amount₹ 75,00,000
Costs
EMD
₹ 1,45,500Document Cost
₹ 1,500Tender Fee
Refer Documents
Summary
Submission Of Proposal For Administrative Approval Of Rs 75.00 Lakhs Of Model Estimate For Construction Of Gplus1 Rcc Dswo Building At Sibsagar, Assam During The Year 2022-23
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WPTBC_37846_1Bid Award Id
ViewTender No
PTDC/Engg/2023-24/213Tender Authority
Welfare Of Plain Tribes And Backward Classes Department ViewPurchaser Address
-Website
http://https://assamtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
5.22 - Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. 5.22.6 - Thermo-Mechanically Treated bars of grade Fe500D or more
3508.73
-
-
... More
5.22 A - Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6 - Thermo-Mechanically Treated bars of grade Fe500D or more
9935.46
-
-
... More
5.9 - Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.1 - Foundations, footings, bases of columns, etc. for mass concrete
30.95
-
-
... More
5.9.6 - Columns, Pillars, Piers, Abutments, Posts and Struts
229.27
-
-
... More
5.9.21 - Lintel, beams, plinth beam, girders, bressumers and cantilevers with water proofy ply 12 mm thick
321.71
-
-
... More
5.9.3 - Suspended floors, roofs, landings, balconies and access platform
281.7
-
-
... More
5.9.19 - Weather shade, Chajjas, corbels etc., including edges
7.9
-
-
... More
5.9.7 - Stairs, (excluding landings) except spiral- staircases
16.63
-
-
... More
5.9.16 - Edges of slabs and breaks in floors and walls. 5.9.16.1 - Under 20 cm wide
14.04
-
-
... More
5.1 - Providing and laying in position specified grade of reinforced cement croncret excluding cost of centering and shuttering.--All works up to plinth level. 5.1.2 - 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregates of 20mm nominal size.
30.57
-
-
... More
5.2 - Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 - 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregates of 20mm nominal size.
6.37
-
-
... More
5.3 - Reinforced cement concrete work in beams, suspended floors, roof having slope up to 150 landings, balcony, shelves, chajja, lintel, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregates of 20mm nominal size.
76.47
-
-
... More
6.1 - Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 - Cement mortar 1:4 (1 cement: 4 coarse sand)
25.11
-
-
... More
4.10 - Providing and laying damp-proof course 40mm thick with cement concret 1:2:4 (1cement: 2coarse sand (zone-III): 4graded stone aggregate 12.5 mm nomial size)
21.94
-
-
... More
2.27 - Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
98.35
-
-
... More
6.13 - Half brick masonry with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in super structure above plinth level up to floor V level. 6.13.2 - Cement mortar 1:3 (1 cement: 3 coarse sand)
532.58
-
-
... More
11.2 - Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
131.13
-
-
... More
4.1 - Providing and laying in position cement croncrete of specifed grade excluding cost of centering and shuttering.--All works up to plinth level. 4.1.8 - 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size from natural sources)
9.83
-
-
... More
11.41 - Providing and laying vitrified floor tiles in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08%
and conforming to IS: 15622, of approved make, in all colours and shades,
laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),
jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the
joints with white cement and matching pigments etc., complete.
11.41.2 Size of Tile 600x600 mm sqm
242.2
-
-
... More
13.5 - 15 mm cement plaster on rough side of single or half brick wall of
mix:
13.5.1 1:4 (1 cement: 4 coarse sand)
794.84
-
-
... More
13.1 - 12 mm cement plaster of mix :
13.1.1 1:4 (1 cement: 4 fine sand)
794.84
-
-
... More
11.46 - Providing and laying Vitrified tiles in different sizes (thickness to be
specified by manufacturer), with water absorption less than 0.08 % and
conforming to I.S. 15622, of approved make, in all colours & shade, in
skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1
cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/
sqm including grouting the joint with white cement & matching pigments
etc. complete.
11.46.2 Size of Tile 600x600 mm
24.5
-
-
... More
9.48 - Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat
with approved steel primer all complete.
9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc.
1801.53
-
-
... More
11.38 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm
(thickness to be specified by the manufacturer), of 1st quality conforming
to IS : 15622, of approved make, in all colours, shades, except White,
Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar
1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3
kg/ sq.m including pointing the joints with white cement and matching
pigments etc., complete.
20.06
-
-
... More
8.31 - Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
85.72
-
-
... More
16.86 - Providing and laying gang saw cut 18 mm thick, mirror polished pre
moulded and pre polished machine cut granite stone of required size
and shape of approved shade, colour and texture in footpath, flooring
cut granite stone of required size and shape of approved shade,
colour and texture in footpath, flooring in road side plazas and similar
locations, laid over 20mm thick base of cement mortar 1:4 (1cement
: 4 coarse sand) including grouting the joints with white cement
mixed with matching pigment, epoxy touch ups etc. complete as
per direction of Engineer-in-Charge.
16.86.1 With granite stone of area less than 0.50 sqm.
36.18
-
-
... More
9.1 - Providing wood work in frames of doors, windows, clerestory windows
and other frames, wrought framed and fixed in position with hold fast
lugs or with dash fasteners of required dia & length (hold fast lugs or
dash fastener shall be paid for separately).
9.1.2 Sal wood
0.36
-
-
... More
9.20 - Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with
frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
15.44
-
-
... More
9.147A - Providing and fixing factory made uPVC white colour casement/casement
cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced
with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC
profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary
stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion
welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished
wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension
in higher side shall be accepted but no extra payment on this account shall be made.
Note: For uPVC frame, 9.147A.3 - Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing
bead of appropriate dimension. ( Area of window upto 2.50 sqm).
34.76
-
-
... More
9.117 - Providing and fixing factory made uPVC door frame made of uPVC
extruded sections having an overall dimension as below (tolerance
±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door
frame to be Jointed with galvanized brackets and stainless steel screws,
joints mitred and Plastic welded. The hinge side vertical of the frames
reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1
mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame
complete as per manufacturer’s specification and direction of Engineerin-
charge
9.117.2 Extruded section profile size 42x50 mm
48.3
-
-
... More
9.118 - Providing and fixing to existing door frames.
9.118.1 24 mm thick factory made PVC door shutters made of styles
and rails of a uPVC hollow section of size 59x24 mm and wall
thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides.
The styles and rails mitred and joint at the corners by means
of M.S. galvanised/ plastic brackets of size 75x220 mm having
wall thickness 1.0 mm and stainless steel screws. The styles
of the shutter reinforced by inserting galvanised M.S. tube of
size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The
lock rail made up of 'H' section, a uPVC hollow section of size
100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the
shutter styles by means of plastic/galvanised M.S. 'U' cleats.
The shutter frame filled with a uPVC multi-chambered single
panel of size not less than 620 mm, having over all thickness
of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels
filled vertically and tie bar at two places by inserting horizontally
6 mm galvanised M.S. rod and fastened with nuts and
washers, complete as per manufacturer's specification and
direction of Engineer-in-charge. (For W.C. and bathroom door
shutter). sqm
7.31
-
-
... More
10.28 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow
tubes, channels, plates etc., including welding, grinding, buffing, polishing
and making curvature (wherever required) and fitting the same with
necessary stainless steel nuts and bolts complete, i/c fixing the railing
with necessary accessories & stainless steel dash fasteners , stainless
steel bolts etc., of required size, on the top of the floor or the side of
waist slab with suitable arrangement as per approval of Engineer-incharge,
(for payment purpose only weight of stainless steel members
shall be considered excluding fixing accessories such as nuts, bolts,
fasteners etc.).
203.96
-
-
... More
13.80 - Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered wall
surface to prepare the surface even and smooth complete.
1327.43
-
-
... More
13.81 - Distempering with 1st quality acrylic distemper, having VOC (Volatile
Organic Compound ) content less than 50 grams/ litre, of approved
brand and manufacture, including applying additional coats wherever
required, to achieve even shade and colour.
13.81.2 Two coats
794.84
-
-
... More
13.44 -Finishing walls with water proofing cement paint of required shade :
13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
532.58
-
-
... More
13.85 - Applying priming coats with primer of approved brand and
manufacture, having low VOC (Volatile Organic Compound ) content.
13.85.1 With ready mixed pink or grey primer on wood work
(hard and soft wood) having VOC content less than
50 grams/ litre
30.87
-
-
... More
13.48.2 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
30.87
-
-
... More
9.70 - Providing and fixing IS : 12817 marked stainless steel butt hinges with
stainless steel screws etc. complete :
9.70.1 125x64x1.90 mm
36
-
-
... More
9.97 - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic
coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed
to required colour or shade, with necessary screws etc. complete :
9.97.1 300x10 mm
36
-
-
... More
9.100 - Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed
to required colour or shade, with necessary screws etc. complete :
9.100.1 125 mm
36
-
-
... More
9.96 - Providing and fixing aluminium sliding door bolts, ISI marked anodised
(anodic coating not less than grade AC 10 as per IS : 1868),
transparent or dyed to required colour or shade, with nuts and screws
etc. complete :
9.96.1 300x16 mm
36
-
-
... More
2.8 - Earth work in excavation by mechanical means (Hydraulic excavator) /
manual means in foundation trenches or drains (not exceeding 1.5 m in
width or 10 sqm on plan), including dressing of sides and ramming of
bottoms, lift upto 1.5 m, including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil.
2.89
-
-
... More
11.2 - Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints
with Jamuna sand, with common burnt clay non modular bricks. a). Brick on flat soling
4.56
-
-
... More
4.1 - Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
0.17
-
-
... More
4.10 - Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural
sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
0.63
-
-
... More
5.1 - Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de
rived from natural sources)
2.58
-
-
... More
5.22 Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete upto plinth level. 5.22.6 - Thermo - Mechanically Treated bars of grade Fe - 500 D or more.
80.11
-
-
... More
5.9 - Centering and shuttering including strutting, propping etc. and removal
of form for
5.9.1 - Foundations, footings, bases of columns, etc. for mass
concrete
6.42
-
-
... More
5.9.21 - Lintels, beams, plinth beams, girders, bressumers and
cantilevers with water proof ply 12 mm thick
4.62
-
-
... More
18.3.1 - Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
256.94
-
-
... More
17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous
china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard
make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and
making good the walls and floors wherever required :
17.3.2 W.C. pan with ISI marked black solid plastic seat and lid
5
-
-
... More
17.7A - Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including
painting of fittings and brackets, cutting and making good the walls wherever required:-
(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
5
-
-
... More
17.28 - Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
17.28.2 Flexible pipe
17.28.2.1 32 mm dia
5
-
-
... More
17.32 - Providing and fixing mirror of superior glass (of approved quality) and
of required shape and size with plastic moulded frame of approved
make and shade with 6 mm thick hard board backing : 17.32.4 Rectangular shape 1500x450 mm
5
-
-
... More
17.34 - Providing and fixing toilet paper holder :
17.34.1 C.P. brass
5
-
-
... More
17.35 - Providing and fixing soil, waste and vent pipes :
17.35.1 100 mm dia
17.35.1.2 Centrifugally cast (spun) iron socket
18
-
-
... More
17.61 - Cutting chases in brick masonry walls for following diameter sand
cast iron/centrifugally cast (spun) iron pipes and making good the
same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6
graded stone aggregate 12.5 mm nominal size), including necessary
plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse
sand) :
17.61.3 50 mm dia
42
-
-
... More
17.71 - Providing and fixing PTMT liquid soap container 109 mm wide, 125
mm high and 112 mm distance from wall of standard shape with
bracket of the same materials with snap fittings of approved quality
and colour, weighing not less than 105 gms.
2
-
-
... More
17.73 - Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
5
-
-
... More
1.1 - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano
type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.1.3 - Group C
12
-
-
... More
1.60 - Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing
as required.
45
-
-
... More
1.70 - Wiring for circuit/ submain wiring alongwith earth wire with the
following sizes of FRLS PVC insulated copper conductor, single
core cable in surface/ recessed steel conduit as required.
1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
110
-
-
... More
E & MI - Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rate, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos, blades, 30 cm long down rod, 2nos. Canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 10% remote or electronic regulator unit for speede control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc. complete as required.
2
-
-
... More
1.35 - Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including
connections etc. as required.
12
-
-
... More
1.25 - Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2
-
-
... More
1.13 - Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm
FRLS PVC insulated copper conductor single core cable for loop earthing as required.
55
-
-
... More
1.33 - Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
10
-
-