Urban Development Department Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Urban Development Department - UDD Tender

Eprocure
Opening Date5 Feb 2019
Closing Date2 Mar 2019
Tender Amount₹ 2,11,85,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Design, installation, development, testing and commissioning of high yield deep tubewells including boring/ drilling in all type of soils, pebbles, gravels, rocks with appropriate rigs and appropriate bit type and size, and collecting sample of soil at every 3.0 m depth or wherever there is a change of strata in sample boxes with the distinguishing marks including arranging and carriage of necessary boring materials / tools / bentonite etc., reboring, Lowering / sinking of well assembly including welding of joints for 300 mm. dia. G.I./ M.S. Housing pipe, and 200 mm. dia. G.I./ M.S. casing pipe, strainer, Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory (physical, biological and chemical), i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc. Supplying and packing pea gravel around the periphery of casing including screening, washing etc. Testing verticality of tube-well by plumbing system and yield test and draw down test by pumping system as per IS: 2800 (Part II) 1979, Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size and Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I) for the tube well etc. all complete as per Employer's Requirements.

25

-

-

... More
Designing, Providing, erecting, testing and commissioning of submersible pump set of required discharge and head as per approved design, conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design,control panel, submersible copper conductor cable in single / double run upto Panel and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump. MS black column Pipe of Heavy duty conforming to IS-1239-Part-I (2004) standards including internal food grade epoxy coating and external enamel painting, all complete as per Employer's Requirements.

25

-

-

... More
Schedule III : Raw Water Transmission main :

-

-

-

... More
Pipes and Specials - Design, supply, laying, hydro-testing, disinfection and comissioning of raw water transmission main of DI S/S ended (K 7) and PN 1.0 rating IS marked pipe of following dia, as per IS-8329-2000 including DI Specials and fittings of class K12, with plain, double socket, Socketed and flanged DI specials conforming to IS: 9523 including various types of bends, tees, reducers, socket and flanged tail pieces, duck foot bends, collars, mechanical joints, dead end caps, blank flanges etc. as per requirement including EPDM rubber gaskets suitable for tyton joints and ‘O” rings required for the jointing of specials with the pipes, nuts and bolts with packing gaskets, including required valves, appurtenances and chamber (air valves, sluice valves and non-return valves, pressure gauges) including excavation in trenches, dismantling of all type of pavements, sand bedding as required, backfilling of trenches and foundations with approved graed excavated materials and approved graded river sand as required including loading and unloading , Shuttering and shoring the earth at different levels in foundations where necessary with required prop, struts, planks, timbers, nails etc. including dewatering if necessary, road restoration, hydro-testing completefor distribution system as per Technical Specifications and direction of Engineer:

-

-

-

... More
150 mm dia Ductile Iron Class K-7 pipes

23000

-

-

... More
400 mm dia Ductile Iron Class K-7 pipes

1500

-

-

... More
Schedule IV : Water Treatment Plant :

-

-

-

... More
Design, supply, construction, installation, testing and commissioning of raw water reservoir cum spray aerator system in as per Employer's Requirements Zone-1B.

1

-

-

... More
Design, supply, construction, installation, testing and commissioning of raw water reservoir cum spray aerator system in as per Employer's Requirements Zone-2B.

1

-

-

... More
Design, supply, construction, installation, testing and commissioning of raw water reservoir cum spray aerator system in as per Employer's Requirements Zone-3B.

1

-

-

... More
Design and Construction of One No. single storied Filter House of minimum 420 Sq.m plinth area as per APWD Specification A in Zone-1B.The cost shall include civil works, foundation, site preparation, Super-roof and Parapet, external finish, sanitary installation, internal water supply works, internal electrification and all other associated works, all complete as per Employer's Requirements.

1

-

-

... More
Design and Construction of One No. single storied Filter House of minimum 420 Sq.m plinth area as per APWD Specification A in Zone-2B.The cost shall include civil works, foundation, site preparation, Super-roof and Parapet, external finish, sanitary installation, internal water supply works, internal electrification and all other associated works, all complete as per Employer's Requirements.

1

-

-

... More
Design and Construction of One No. single storied Filter House of minimum 420 Sq.m plinth area as per APWD Specification A in Zone-3B.The cost shall include civil works, foundation, site preparation, Super-roof and Parapet, external finish, sanitary installation, internal water supply works, internal electrification and all other associated works, all complete as per Employer's Requirements.

1

-

-

... More
Design and Construction of One No. single storied Chlorinator Room of minimum 60 Sq.m plinth area as per APWD Specification A in Zone-1B.The cost shall include civil works, foundation, site preparation, Super-roof and Parapet, external finish, sanitary installation, internal water supply works, internal electrification and all other associated works, all complete as per Employer's Requirements.

1

-

-

... More
Design and Construction of One No. single storied Chlorinator Room of minimum 60 Sq.m plinth area as per APWD Specification A in Zone-2B.The cost shall include civil works, foundation, site preparation, Super-roof and Parapet, external finish, sanitary installation, internal water supply works, internal electrification and all other associated works, all complete as per Employer's Requirements.

1

-

-

... More
Design and Construction of One No. single storied Chlorinator Room of minimum 60 Sq.m plinth area as per APWD Specification A in Zone-3B.The cost shall include civil works, foundation, site preparation, Super-roof and Parapet, external finish, sanitary installation, internal water supply works, internal electrification and all other associated works, all complete as per Employer's Requirements.

1

-

-

... More
Design and Construction of One No. single storied Operators' Room of minimum 100 Sq.m plinth area as per APWD Specification A in Zone-1B.The cost shall include civil works, foundation, site preparation, Super-roof and Parapet, external finish, sanitary installation, internal water supply works, internal electrification and all other associated works, all complete as per Employer's Requirements.

1

-

-

... More
Design and Construction of One No. single storied Operators' Room of minimum 100 Sq.m plinth area as per APWD Specification A in Zone-2B.The cost shall include civil works, foundation, site preparation, Super-roof and Parapet, external finish, sanitary installation, internal water supply works, internal electrification and all other associated works, all complete as per Employer's Requirements.

1

-

-

... More
Design and Construction of One No. single storied Operators' Room of minimum 100 Sq.m plinth area as per APWD Specification A in Zone-3B.The cost shall include civil works, foundation, site preparation, Super-roof and Parapet, external finish, sanitary installation, internal water supply works, internal electrification and all other associated works, all complete as per Employer's Requirements.

1

-

-

... More
Design and Construction of One No. single storied Guard Room of minimum 12 Sq.m plinth area as per APWD Specification A in Zone-1B.The cost shall include civil works, foundation, site preparation, Super-roof and Parapet, external finish, sanitary installation, internal water supply works, internal electrification, all complete as per Employer's Requirements.

1

-

-

... More
Design and Construction of One No. single storied Guard Room of minimum 12 Sq.m plinth area as per APWD Specification A in Zone-2B.The cost shall include civil works, foundation, site preparation, Super-roof and Parapet, external finish, sanitary installation, internal water supply works, internal electrification, all complete as per Employer's Requirements.

1

-

-

... More
Design and Construction of One No. single storied Guard Room of minimum 12 Sq.m plinth area as per APWD Specification A in Zone-3B.The cost shall include civil works, foundation, site preparation, Super-roof and Parapet, external finish, sanitary installation, internal water supply works, internal electrification, all complete as per Employer's Requirements.

1

-

-

... More
Design, supply, erection, testing and commissioning of all Mechanical works for WTP including spray aerator system, raw water feed pumps, dual media type pressure filters with back-wash systtem, air blowers, online chlorinator with booster pumps, EOT crane, Diesel Generator set, all internal connection & by-pass piping system including Valves and other appurtenances of dia as required with pipes and specials such as bend, tee, reducer / enlarger, end plug, socket, spigot, etc. all complete as per Employer's Requirements, in Zone-1B.

1

-

-

... More
Design, supply, erection, testing and commissioning of all Mechanical works for WTP including spray aerator system, raw water feed pumps, dual media type pressure filters with back-wash systtem, air blowers, online chlorinator with booster pumps, EOT crane, Diesel Generator set, all internal connection & by-pass piping system including Valves and other appurtenances of dia as required with pipes and specials such as bend, tee, reducer / enlarger, end plug, socket, spigot, etc. all complete as per Employer's Requirements, in Zone-2B.

1

-

-

... More
Design, supply, erection, testing and commissioning of all Mechanical works for WTP including spray aerator system, raw water feed pumps, dual media type pressure filters with back-wash systtem, air blowers, online chlorinator with booster pumps, EOT crane, Diesel Generator set, all internal connection & by-pass piping system including Valves and other appurtenances of dia as required with pipes and specials such as bend, tee, reducer / enlarger, end plug, socket, spigot, etc. all complete as per Employer's Requirements, in Zone-3B.

1

-

-

... More
Design, supply, erection, testing and commissioning of all Electrical works for WTP including elec. motor, electric cables, transformer, MCC panel, earthing, Cable trench, Cable tray, Gland and lugs, internal lighting & exhaust system , external lighting etc and all other associated works as per Employer's Requirements in Zone-1B.

1

-

-

... More
Design, supply, erection, testing and commissioning of all Electrical works for WTP including elec. motor, electric cables, transformer, MCC panel, earthing, Cable trench, Cable tray, Gland and lugs, internal lighting & exhaust system , external lighting etc and all other associated works as per Employer's Requirements in Zone-2B.

1

-

-

... More
Design, supply, erection, testing and commissioning of all Electrical works for WTP including elec. motor, electric cables, transformer, MCC panel, earthing, Cable trench, Cable tray, Gland and lugs, internal lighting & exhaust system , external lighting etc and all other associated works as per Employer's Requirements in Zone-3B.

1

-

-

... More
Design, supply, erection, testing and commissioning of all Instrumentation and Control & Autimation (PLC & SCADA) system works for WTPs, OHRs and IPS including flow measuring system and transmitters ,pressure measuring system and transmitters, level measuring system and transmitters, Quality control instruments (online analysers and off-line laboratory), junction boxes, instrument wiring/ cabling, PLC hardware and software, PC based SCADA system, IC Panels, UPSs and all other associated works etc. complete as per Employer's Requirements, for Zone-1B, 2B, 3B, 1A, 2A, 3A and Intermediate Pumping Station in 1B.

1

-

-

... More
Design, supply, erection, testing and commissioning of all Electro - Mechanical works for augmentation of existing WTP in Zone-1A, including spray aerator system, clear water feed pumps with motors, filter inlet and outlet piping arrangement with all appurtenances viz. control valves, flow controller etc. in the filter unit for clarified water inlet, filtered water outlet, back wash water inlet, rinse water outlet etc. for PSF, air blowers, online chlorinator with booster pumps and motors, Diesel Generator set, all internal connection & by-pass piping system including Valves and other appurtenances of dia as required with pipes and specials such as bend, tee, reducer / enlarger, end plug, socket, spigot, etc. all complete as per Employer's Requirements.

1

-

-

... More
Design, supply, erection, testing and commissioning of all Electr-Mechanical works for augmentation of existing WTP in Zone-2A, including spray aerator system, clear water feed pumps with motors, filter inlet and outlet piping arrangement with all appurtenances viz. control valves, flow controller etc. in the filter unit for clarified water inlet, filtered water outlet, back wash water inlet, rinse water outlet etc. for PSF, air blowers, online chlorinator with booster pumps and motors, Diesel Generator set, all internal connection & by-pass piping system including Valves and other appurtenances of dia as required with pipes and specials such as bend, tee, reducer / enlarger, end plug, socket, spigot, etc. all complete as per Employer's Requirements.

1

-

-

... More
Design, supply, erection, testing and commissioning of all Elcetr-Mechanical works for augmentation of existing WTP in Zone-3A, including spray aerator system, clear water feed pumps with motors, filter inlet and outlet piping arrangement with all appurtenances viz. control valves, flow controller etc. in the filter unit for clarified water inlet, filtered water outlet, back wash water inlet, rinse water outlet etc. for PSF, air blowers, online chlorinator with booster pumps and motors, Diesel Generator set, all internal connection & by-pass piping system including Valves and other appurtenances of dia as required with pipes and specials such as bend, tee, reducer / enlarger, end plug, socket, spigot, etc. all complete as per Employer's Requirements.

1

-

-

... More
Boundary wall, land Development, landscaping and horticulture for Treatment Plant and OHR Location in Zone-1B.

1

-

-

... More
Boundary wall, land Development, landscaping and horticulture for Treatment Plant and OHR Location in Zone-2B.

1

-

-

... More
Boundary wall, land Development, landscaping and horticulture for Treatment Plant and OHR Location in Zone-3B.

1

-

-

... More
Schedule V : Intermediate Pumping Station in Zone-1B

-

-

-

... More
Design, construction, testing and commissioning of Civil works of Raw water sump cum pump house including SCADA room for intermediate pumping station in Zone-1B of minimum size of 40sq.m., all complete as per Employer's Requirements.

1

-

-

... More
Design, installation, testing and commissioning of all electro-mechanical works inclduing Raw Water Pump of Horizontal Centrifugal Split Casting pumps with motor, CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, sluice valve, air valve inclduing any surge control devices, necessary electrical works all complete

1

-

-

... More
Schedule VI : Elevated Service Reservoirs

-

-

-

... More
Design, construction, supply, erection, testing and commissioning of 3 Nos Zonal Over head service reservoirs of Circular shape, RCC framed staging and capacities as given below at different locations under the command areas to be served with all inlet, outlet, drain, overflow pipe works and control valves and all other associated works as specified in various chapters of this document (ICA requirements are included in WTP Schedule).

-

-

-

... More
Over head service reservoirs of Circular shape, RCC framed staging and 3300 cu.m capacity and minimum 20 m staging height for Zone-1B, all complete as per Employer's Requirements.

1

-

-

... More
Over head service reservoirs of Circular shape, RCC framed staging and 2000 cu.m capacity and minimum 20 m staging height for Zone-2B, all complete as per Employer's Requirements.

1

-

-

... More
Over head service reservoirs of Circular shape, RCC framed staging and 2500 cu.m capacity and minimum 20 m staging height for Zone-3B, all complete as per Employer's Requirements.

1

-

-

... More
Repair work of existing 2 Nos Zonal Over head service reservoirs and pathways as per actual requirements/ Employer's Requirements (ICA requirements are included in WTP Schedule).

-

-

-

... More
Repair works of over head service reservoir and pathways in Zone-1A

1

-

-

... More
Repair works of over head service reservoir and pathway in Zone-3A

1

-

-

... More
Schedule VII : Distribution System

-

-

-

... More
Pipes and Specials - Design, supply, laying, hydro-testing, disinfection and commissioning of distribution pipe network of DI S/S ended (K 7) and PN 1.0 rating IS marked pipe of following dia, as per IS-8329-2000 including DI Specials and fittings of class K12, with plain, double socket, Socketed and flanged DI specials conforming to IS: 9523 including various types of bends, tees, reducers, socket and flanged tail pieces, duck foot bends, collars, mechanical joints, dead end caps, blank flanges etc. as per requirement including EPDM rubber gaskets suitable for tyton joints and ‘O” rings required for the jointing of specials with the pipes, nuts and bolts with packing gaskets, including excavation in trenches, dismantling of all type of pavements, sand bedding as required, backfilling of trenches and foundations with approved graded excavated materials and approved graded river sand as required including loading and unloading , Shuttering and shoring the earth at different levels in foundations where necessary with required prop, struts, planks, timbers, nails etc. including dewatering if necessary, road restoration, hydro-testing completefor distribution system as per Technical Specifications and direction of Engineer:

-

-

-

... More
100 mm dia Ductile Iron Class K-7 pipes

105000

-

-

... More
150 mm dia Ductile Iron Class K-7 pipes

39000

-

-

... More
200 mm dia Ductile Iron Class K-7 pipes

28000

-

-

... More
250 mm dia Ductile Iron Class K-7 pipes

6500

-

-

... More
300 mm dia Ductile Iron Class K-7 pipes

7000

-

-

... More
350 mm dia Ductile Iron Class K-7 pipes

1500

-

-

... More
400 mm dia Ductile Iron Class K-7 pipes

3500

-

-

... More
500 mm dia Ductile Iron Class K-7 pipes

3500

-

-

... More
600 mm dia Ductile Iron Class K-7 pipes

2000

-

-

... More
700 mm dia Ductile Iron Class K-7 pipes

1500

-

-

... More
Valves and Appurtenances - Design, supply, installation, testing and commissioning of manually operated Ductile Iron of DIN 1693 Grade - GGG 40/ GGG 50/ SG Iron of IS 1865 Grade - 400/12/500/7. Double Flanged Non Rising Type Sluice Valve (for control , wash out, DMA meters, fire hydrants) of various size as per CPHEEO, as per IS 14846/2000 (PD Type) PN 1.0 having seat of body/wedge face ring Gunmetal to IS 318 LTB 2, Stem SS AISI 410 with manual handhweel operation. Flange Drilled as per IS 1538 Table IV & VI Flat Face, including Ductile Iron companion Flange as per IS : 9523/2000 for installation of valves, Providing flanged joints to double flanged pipes and specials, all inclusive, with testing of joints and including supplying bolts, nuts and 3 mm thick rubber insertion sheet all complete as per Technical Specifications and as per direction of Engineer.

-

-

-

... More
Valves and Appurtenances - Design, supply, installation, testing and comissioning of manually operated Ductile Iron of DIN 1693 Grade GGG 40/50 or SG Iron of IS 1865 Grade 400/12, 500/7 Flanged End temper proof air valve as per AWWA C512 or IS 14845 of 80mm dia of PN 1.0 having seat ring nozzle gunmetal covered with EPDM float of chamber : SS AISI 304 with ductile iron slucie valve as per IS 14846 PN 1.0 having seat ring gunmetal to IS 318 LTB 2, Stem SS AISI 410 with manual handwheel operation flange drilled to IS 1538 Table IV & VI Flat Face nclduing Ductile Iron companion Flange as per IS : 9523/2000 for installation of valves, Providing flanged joints to double flanged pipes and specials, all inclusive, with testing of joints and including supplying bolts, nuts and 3 mm thick rubber insertion sheet all complete as per Technical Specifications and as per direction of Engineer.

5

-

-

... More
Valve Chambers - Design and Construction of RCC and Brick masonry chambers for valves, hydrants, DMA meters etc. including cost of reinforcement, PCC (1:4:8) and RCC (M20) work, cost of supply and bending and binding of steel with required shuttering, cost of brick work (230/ 350 mm thick Brickwork in CM 1:6) with plaster (10mm thick of 1:6) from inside and outside , precast slabs and supply and installation of SFRC frame and coves wherever required, including excavation,dewatering, formwork, backfilling, road restoration and all the miscellaneous items of work, but excluding the supply and installation of pipes and specials, valves etc. as per specification, approved design and drawings.

-

-

-

... More
Pipe jack for Railway crossing with Jacking and Pushing method. The item include design, fabricating, supplying, pushing, jointing required diameter of MS casing pipe( min 20mm thick) of required length, construction of Receiving and Jacking pit with suitable shoring and strutting (if required), including installation of jacking platform, thrust resistant arrangement of required capacity including , hydraulic jacking with required accessories, required excavation inside the jacking pipe and disposal the same, etc. all complete as per drawing, specification and as directed.

2

-

-

... More
Survey, design, supply and construction of bridge for Nullah crossing with RCC (M20) and Structural steel works including earthwork in excavation, backfilling, bolder soling, PCC (1:4:8), formwork, reinforcement etc. as per approved designs and drawings.

1

-

-

... More
DMA meters - Design, Supply, install and commission, including calibration in third party laboratory, full bore battery operated Electromagnetic Flow Meter (EMF) as per ISO 4064, for potable water with accuracy as per specification, with in-built wireless communication (GSM/ GPRS model with data logger) along with one number of battery operated Pressure Transmitter (ratio metric type) and integration of pressure signal with DMA flow meter wireless communication modem, inclduing software for datalogging with workstation, as per given specifications for following sizes including sensor, transmitter surge arrestor, cables, pipe cutting, leveling and installation of flow meter and pressure transmittor in the pipelines with necessary tool tackles etc complete, as may be required at site & based on technical specifications

-

-

-

... More
Battery operated full bore EFM with build-in GSM/ GPRS modem DN 150 mm and above as per required dia , including liner, tube and ratiometric pressure transmitters

28

-

-

... More
Ip-65 Lockable Enclosure

28

-

-

... More
Static IP included with Sim cards, Data Charges

28

-

-

... More
Fire Hydrants - Providing,Fixing, testing &Commissioning of Single Headed Gun Metal ISI Marked oblique pattern Hydrant Landing Valve with 80 mm dia, flanged inlet & 63 mm dia instantaneous type female outlet complete with cap and chain, twist release lug and all accessories as per IS:5290-1993(third revision) (Type-'A'), Cast Iron Sluice Valve/ Gate Valve confirming to IS:14846/2000 complete with matching flanges, rubber insertion, nuts, bolts and washer etc., inclduing Ductile Iron Flanged socket as per IS : 9523/2000 PN-16 and flanged joints to double flanged pipes and specials with testing of joints and including supplying bolts, nuts and 3 mm thick rubber insertion etc. for installation of valve all complete as per specification and as directed. (MAKE:ESSEL/WINCO/NEWAGE/ equivalent)

20

-

-

... More
Schedule VIII : Service Connections and Meter Installation

-

-

-

... More
Domestic Water Meter and AMR: Providing, installing and giving satisfactory field testing of water meter (domestic type) with ISI mark as per IS 779/1994 , horizontal inferential multijet type with magnetic drive and dry dial suitable for ambient 50º C Temperature duly sealed against tampering, AMR ready/ compatible, complete with couplings at both ends and conforming to class B as per IS 779/1994 (VI Revision) with ISI mark along with manufacturer's test certificate and guarantee certificate, with 5 years warranty, including cost of all materials, as per specification

-

-

-

... More
15 mm Multijet type Water Meters

5522

-

-

... More
20 mm Multijet type Water Meters

16566

-

-

... More
25 mm Multijet type Water Meters

4141

-

-

... More
40 mm Multijet type Water Meters

1380

-

-

... More
AMR module - RF based / GSM, GPRS AMR technology, wirelessly direct fitted on the meter complete with as per specification

27609

-

-

... More
Service Connection: Providing and making house service connections from water supply distribution DI pipe line upto water meter chamber inside the property using HDPE (Class-PE 80) PN 6 composite pipes. The item consisting of composite pipes of HDPE pipe below the ground level and GI class B pipe above the ground level including supply and fixing of ferrules, electro fusion saddle, clamps, rubber sheets, tapping, compression fittings, meter Chamber etc, complete including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer-in-Charge.

27609

-

-

... More
Schedule IX : Operation and Maintenance

-

-

-

... More
Operation and Maintenance of the entire Water Supply System including Raw water Intake Pumping System on Floating barge,Raw water transmission main,Water Treatment Plant ,clear water transmission main,Elevated service reservoirs and Distribution System with supply of Man-power,spares,chemicals & consumables, tools and tackles, fuel for operation of DG set when required and others (except power/ electricity cost, which shall be paid by the Employer) for 10 years .

-

-

-

... More
1st year of Operation and Maintenance

1

-

-

... More
2nd year of Operation and Maintenance

1

-

-

... More
3rd year of Operation and Maintenance

1

-

-

... More
4th year of Operation and Maintenance

1

-

-

... More
5th year of Operation and Maintenance

1

-

-

... More
6th year of Operation and Maintenance

1

-

-

... More
7th year of Operation and Maintenance

1

-

-

... More
8th year of Operation and Maintenance

1

-

-

... More
9th year of Operation and Maintenance

1

-

-

... More
10th year of Operation and Maintenance

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.