Urban Development Department Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Urban Development Department - UDD Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date10 Oct 2023
Closing Date30 Oct 2023
Tender Amount₹ 2,09,85,000 
Notes
Download

Costs

Summary

Renovation, Testing, Commissioning And Operation And Maintenance Of Goalpara Town Water Supply Scheme

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Renovation, Testing, Commissioning and Operation and Maintenance of Goalpara Town Water Supply Scheme
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying, installation testing & commissioning of raw water pump sets including starter panel , cables,common header etc.

-

-

-

... More
Supply, installation, testing and commissioning of electrical driven CentrifugalRaw water pumping set ( couple type ) with suitable for operation with 415 (+10 %) V, 3-phase, 50 Hz + 3% power supply with suitable size & specification of pump/ motor in all respect with specifacation - split case multistage (2 stg) pump set discharge 60lps, head -120m with 110kw/ 150hp/ 4 pole motor along with the assessories (MOC; Ci- casing + CF8M Impeller( Stainless steel) + SS shaft) along with base plate, coupling, coupling guard, foundation nuts & bolts, construction & fitting of MS joist 200x6 joist foundation, supplying & fitting of starter panel of required specifification, necessary cables for connection power line from main panel board to startr panel & starter panel to pumpset , supplying & installation of one change over of required spacification all complete as directed.

2

-

-

... More
Supplying, installation testing & commissioning of main Panel board , including cables required to connect from transformer with all other accessories at Barge Site

-

-

-

... More
Supplying fabrication & erection , testing , commissioning of vermin and dust proof (P-43 protection ) totally enclosed cubical type compartmental floor mounting panel board of size 2300 mm x1150 mm x 500 mm made of 16 SWG( 1.66mm thick CR sheet roofing on the top complete painting with 2 coats of red oxide metal primer and 2 coat of enamel paint. The panel board is to be erected in MS floating Barge including all complete neatlly wiring done with the provision for the flowing electrical accessories. Incomer 800A , 4 pole MCCB and provision for 11 nos TPN MCCB (i)0- 500 V(digital ) Voltmeter (ii) 0-350 A Digital ammeter-1(ii)Voltmeter selector switch (iii)Ammeter selector switch-1(iv)Indicator lamp-(R.Y.B)-3(v)Control wiring along with required size of copper busher (vi) @A solid lock fuse -3 nos (vii) 800/5 CT coil ( required capacity of MCCB for 180 HP pump motor , 5 HP Vaccum pump and internal electrification along with Copper armoured cable for connection of pumping sets from Pnnel Board and internal wiring for Ligting arrangment (4 nos bulb/ Tube light. ) , Required capacity of MCCB for pumps & Vaccum pump, and lighting .

1

-

-

... More
Supply, fitting & fixing of Common header with 8 mm thich 400mm dia. , 4.0m long, with 8mm thick 200mm dia 30.0m long pipe , 14 nos flange for installtion of valves ( S/v & NRV)MS pipe for connecting 2 nos Raw water pump and Raw water pummping main and with necessary D/F Sluice Valve PN1.6 for outlet ( 200 mm dia- 4 nos and Inlet ( 200 mm dia 2 nos ) , Foot valves - 2 nos and non return valves PN1.6 200 mm dia- 2 nos , Nut- bolt, Protection Jali with MS Rod (8 mm dia ) for around inlet foot valves , painting .in all respect.

1

-

-

... More
Supplying & laying following size PVC/XLPE insulated and PVC sheathed 1.1kv grade solid aluminium conductor upto 10sqm balance stranded conductor , xlpe insulated , cores laid up, PVC tape inner sheathed , armoured for single core up to 70sqmm balance aluminium strip , galvanised for cables upto to 2x10 sqm 3x10 sqm , 4x6 sqm baqlance all galvanised steel strp, mextruded PVC type ST@ sheathed , 650/1100v grade as per IS 7908 (part 1) 1988 armourured UG cable UG cable laid in ground / partially in air required for termination over deptt of 75cm , refilling, trotective brick covering sand cushioning etc. complete handling of surplus spoil, debris to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/ Polycab/ Gloster/ Finolex make or equivalant.

-

-

-

... More
i) 185 sqmm 3 & 1/2 core armoured UG cable for transformer to main panal 30m

30

-

-

... More
Repairing and replacement of Sluice Valves with / short / long spindle ( 7 nos) , MS door and Steel window & ventilation with glass pan . Dozing motors, Flush mixture mechanical works , Wiring , replacement of cable as per required diameter, Tube light, Ceiling Fan, plastering as where necessary , Air blower at Treatment Plant

1

-

-

... More
Supplying, spreading of filter media of filter Beds including lateral UPVC pipes

-

-

-

... More
Supplying and placing of river gravel of different size for using as filter media free from dirt, dust or any foreign materials including inorganic dalts etc with range of size 40 mm to 50 mm - 200 mm thicness, 32 mm to 40 mm - 200 mm thickness , 12 mm to 20 mm - 100 thickness and 6 mm to 212 mm - 100 thickness . and Coarse sand to use as filter media for rapid gravity filter effective size from 0.45mm to 0.70 mm and uniformity co-efficient between 1.70 and 1.80 all complete with 600 mm thickness as directed by EIC. The sand shall be hard and reistant quartzite and free from dust, clay and fine particles etc. and gravel should be freeform dust and to be washed for cleaning incuding Latteral Pipe for Filter bed : Supplying fitting fixing of UPVC pipe of 110mm dia with 6 kg/ CM2 . Including making 12 mm hole for filtration of water including Bend , Tee all complete

1

-

-

... More
Main Panel Boaard at Treatment Plant site

-

-

-

... More
Repairing of main panel Board at treatment plant ----Supplying, fabrication & erection , testing , commissioning of vermin and dust proof (P-43 protection ) totally enclosed cubical type compartmental floor mounting panel board of size 2300 mm x1150 mm x 500 mm made of 16 SWG( 1.66mm thick CR sheet roofing on the top complete painting with 2 coats of red oxide metal primer and 2 coat of enamel paint. The panel board is to be erected in MS floating Barge including all complete neatlly wiring done with the provision for the flowing electrical accessories. Incomer 800A , 4 pole MCCB and provision for 11 nos TPN MCCB (i)0- 500 V(digital ) Voltmeter (ii) 0-250 A Digital ammeter-1(ii)Voltmeter selector switch (iii)Ammeter selector switch-1(iv)Indicator lamp-(R.Y.B)-3(v)Control wiring along with required size of copper busher (vi) @A solid lock fuse -3 nos (vii) 250/5 CT coil ( required capacity of MCCB for back wash pump ( 10 HP ) and Vaccum pump (20 HP ) in all respect.

1

-

-

... More
Supplying / installtion of including supplying installtion of motor of clarifier bridge of treatment plant

-

-

-

... More
Repairing & painting of Flocculator vertical hanger (outer) 65x5 ISA,Flocculatorvert. hanger (inner) 65x5 ISA,Scrapper- hanger link 50x6 ISA1,Scrapper- hanger link 50x6 ISA2,Link-hanger junction plate -8 PL1,Link-hanger junction plate -8 PL2Scrapper blade -50x10 flat,Diagonal scrapper stiffner -30x6 flat,Flocculator paddle-6PL,Paddle fixer- 65x6 ISA,otating spindle 80 mm ISRO in all respct for moving

450

-

-

... More
Supplying , fitting & fixing of 2 nos Motor, rotor, gear assembly with all accessories with RPM 1400 including pannel Board for clrifluculator bridge

-

-

-

... More
i) 15 HP Motor

15

-

-

... More
ii) 12 HP Motor

12

-

-

... More
Labour Charge for removing Mud from Clarifluculator and cleaning the inside properly for smoothly moving the clarifier bridge.

1

-

-

... More
Painting of complete Tratment Plant and boundary wall

-

-

-

... More
Painting of complete tratment plant ( Filte house, Chemical house, Raw water Channel and Aeraor including boundary wall with supply of all materials making all arrangements for paintings all complete as directed . Two coats at Inside Acrylic emulsion wall paint and outside weather coats . Boundary wall painting with two coats of Durocem/ Snowcem including removing of old paint . Metal surface with red oxside primer and two coats of santhetic enamal paint after removing old paint

1

-

-

... More
Supply, laying, Road Crossing, Culvert Crossing, Drain/ Nalla Crossing and commissioning of distribution pipe network by High Density polyethylene [ HDPE (PE80)] pipes including all specials confirming to IS 4984 and the specifications, including third party inspection, all taxes and duties, transportation, freight charges, loading and unloading, conveyance to the project site and stacking with cost of all labor and material , including excavation in trenches, dismantling of all type of pavements, sand bedding as required, backfilling of trenches and foundations with approved graded excavated materials and approved graded river sand as required including loading and unloading , Shuttering and shoring the earth at different levels in foundations where necessary with required prop, struts, planks, timbers, nails etc. including dewatering if necessary, complete for distribution system as per Technical Specifications per Employer's Requirements.with pipe diameters- 100 mm dia - 4 nos, 150 mm dia-2 nos , 200 mm dia-2 nos and 250 mm dia - 2 nos

-

-

-

... More
100 mm dia pipe

150

-

-

... More
160 mm dia pipe

150

-

-

... More
200 mm dia pipe

100

-

-

... More
For Road Crossing, Culvert Crossing, Drain/ Nalla Crossing with MS pipe having 7.90 mm thickness including welding painting fitting & fixing alongwith all required materials and restoration in all respect

-

-

-

... More
100 mm dia pipe

4

-

-

... More
160 mm dia pipe

2

-

-

... More
200 mm dia pipe

2

-

-

... More
250 mm dia pipe

2

-

-

... More
Trial Runn of Goalpara WSS for 6 month

-

-

-

... More
For Operation and maintenance of the scheme required the materials like Alum, Bleaching Poweder, Lime and Power consupsion ( ASEB ) bill both intake and Treatment Plant site for 6 months

6

-

-

... More
Payment for outstanding Electricity Bill (arear) including reconnection charges as admissible of APCDL

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.