Urban Development Department Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Urban Development Department - UDD Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date16 Oct 2024
Closing Date5 Nov 2024
Tender Amount₹ 2,03,69,498 
Notes
Download

Costs

Summary

Execution, Testing And Commissioning Of Balance Works Of Sibsagar Town Water Supply Scheme

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. Building floor

93

-

-

... More
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).

5.03

-

-

... More
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume Building floor

9.3

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.- 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.

1347.05

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for-5.9.1- Foundations, footings, bases of columns, etc. for mass concrete.

23.04

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for- 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers

27.48

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for-5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts14 Nos Colm. (120 x 120) above PL

26.61

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for- 5.9.3-Suspended floors, roofs, landings, balconies and access platform

14.7

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing & reinforcement – All work upto Plinth level : -a) In a Substructure upto plinth level: M 20 Grade : - 1: 1.5: 3

6.61

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2- 1:1.5:3 (1 cement : 1.5 coarse sand derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

4.75

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)

1.43

-

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.- 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand)

101.49

-

-

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

101.49

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1:- 1:4 (1 cement: 4 fine sand)

293.77

-

-

... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 11.6.1 18 mm thick

43.86

-

-

... More
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

88.95

-

-

... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over

28.66

-

-

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.3 Kiln seasoned and chemically treated hollock wood Door1200X2100 (H), Window W1000X1200

0.81

-

-

... More
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).

88

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.2 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws,With ist class hollock wood- 30 thk paneled door shutter.

3.61

-

-

... More
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 9.9.2 Kiln seasoned and chemically treated hollock wood- 9.9.2.2- 30 mm thick , (i) With ist class Bhola/ Gamari wood- 30 thk glazed window shutter.

29.39

-

-

... More
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : 9.7.7 Float glass panes -9.7.7.1 4 mm thick glass pane (weight not less than 10kg/sqm).

11.2

-

-

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete : 9.96.1- 300x16 mm,a) Sliding door bolts-250 mmX 16 mm

2

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :

-

-

-

... More
a) 250mm X 10 mm

6

-

-

... More
b) 100mmx10 mm

52

-

-

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :

-

-

-

... More
a) Door handle-125 mm

4

-

-

... More
b) Window handle- 100 mm

26

-

-

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc. M.S. flat = 20 mm X 5 mm

266.2

-

-

... More
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.-12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m² sqm,Roofing sheets

136.37

-

-

... More
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. -12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m² ,Ridgings

16.43

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. -10.16.2 Hot finished seamless type tubes kg

1569.1

-

-

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

330

-

-

... More
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). - 6 mm thick Cement fiber board as per IS: 14862

90

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface .

158.19

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade . Old work (Two or more coat applied @ 1.67 ltr/10 sqm on existing cement paint.

156.24

-

-

... More
Colour washing such as green, blue or buff to give an even shade : New work (two or more coats) with a base coat of white washing with lime

205.6

-

-

... More
Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)

35.9

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work

35.9

-

-

... More
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works

70.3

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 13.61.1 Two or more coats on new work

70.3

-

-

... More
B. MS Floating Barge body strengtheng

-

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works .Bottom L/S sleeper ISMC-75,Verical support ISMC-75,Deck bottom support post plate ISMC-75, Post plate top sleeper ISMC-75,Cross bracing ISMC-75, Bolt clamping plate- 200x100x10 Pl

776.62

-

-

... More
Providing and fixing bolts including nuts and washers complete. ,Base plate clamping bolt 5/8"x16",Nut bolt for hose pipe

122.48

-

-

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.3 Kiln seasoned and chemically treated hollock wood ,Pump base plate support 6"x4"x7'

0.13

-

-

... More
Applying priming coat:13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works Bottom L/S sleeper ISMC-75,Verical support ISMC-75,Deck bottom support post plate ISMC-75,Post plate top sleeper ISMC-75,Cross bracing ISMC-75,Bolt clamping plate- 200x100x10 Pl, Barge body hull both faces, Deck top & bottom

355.75

-

-

... More
Coal tarring two coats on new work using 0.16 Litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively. sqm 55.55

355.75

-

-

... More
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.-12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m² sqm Roofing sheets

131.63

-

-

... More
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. -12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m²

15.2

-

-

... More
Supplying and fitting Steel Wire Rope of 16mm dia ,

60

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.

4.7

-

-

... More
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.

3.92

-

-

... More
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume

0.39

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.- Thermo-Mechanically Treated bars of grade Fe-500D or more.

200

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for-5.9.1- Foundations, footings, bases of columns, etc. for mass concrete RCC anchor block 1.0x1.0x1.0 m

8.8

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing & reinforcement – All work upto Plinth level : -a) In a Substructure upto plinth level: M 20 Grade : - 1: 1.5: 3

2

-

-

... More
Supplying of various sizes of wrenches, Faorah/kudali-2 nos, spades-2 nos, Gaitha-2 nos, Trunk with lock and keys -1 set etc. suitable for piping work as directed by Eingineer-in-charge (Each set)

2

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes kg 154.90 = Common header = Providing, Fixing, Testing & Commissioning of Mild Steel Black Pipe (IS:1239 Part-I) Heavy class including cutting, screwing, welding etc and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps hangers etc including cutting holes and chases in brick or RCC walls/slabs and making good the same to the approval of Engineer - in- charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. Approved make of pipes: Tata /Jindal / Nezone/Suriya , including 250 dia/ 200 mm flanged reducer /enlarger as required,Common header at Barge 400 mm dia 9 mm thick, Pump connecting pipe 200 NB 8 mm thk

762.61

-

-

... More
Providing, Erection, Testing & Commissioning of Cast Iron Sluice Valve/Gate valve confirming to IS:14846/2000 complete with matching flanges, rubber insertion, nuts, bolts and washer etc of following size complete as required. Approved make of valve: KALPANA/ZOLOTO /HONEYWELL b) 200 mm dia

2

-

-

... More
Supplying & Fixing Cast iron body Non Return valves complete with matching flanges,rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd. Approved make of valve: KALPANA/ZOLOTO/ HONEYWELL- b) 200 mm dia

2

-

-

... More
C. Raw water pumping main with D.I. pipe to treatment plant

-

-

-

... More
Earth work in excavation in black toping road surface (average thickness of black toping 35mm) including the removal of road metal, boulders and refilling the same properly and restore the road surface to its original condition (except black toping as the black toping to be done by the P W D on necessary payment all complete as directed.

40.2

-

-

... More
Earth work in excavation for metallic road surface (average thickness of 40 cm) including the removal of road metal, boulders and including restoration of road surface original condition all complete as directed.

40.2

-

-

... More
Earth in excavation in foundation trenches including refilling the quantity as necessary after completion of works of pipe line dressing, ramming, watering etc. and removal of surplus earth with 50 M lead and lift up to 1.5 M all complete as directed including boiling out water where necessary.b) Bastic land, tillah soil, hard soil, mixed with moram gravel and boulder up to one man size.

36.78

-

-

... More
Labour charge for carrying and laying DI pipes and specials (Class-7) in position, in line and level complete as directed for 350mm dia DI pipe

60

-

-

... More
Providing joint to DI/S&S pipes including cutting the pipes where necessary and supplying all jointing materials where necessary with testing of the joints all complete as directed. for 350 mm dia DI pipe

13

-

-

... More
Providing rubber gasket joints to C.I. pipes and specials with testing of joints including carriage of the materials but excluding the cost of rubber gasket all complete as directed.for 350 mm dia

2

-

-

... More
Labour charge for carrying, placing in position, fitting and fixing C.I. sluice valve (with wheel & cap) C.I. refluxe valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc (the tail pieces if required will be paid separately) all complete as directed (one valve and two flanged joints d) 350 mm dia

1

-

-

... More
Labour charge for carrying, placing in position, fitting and fixing C.I. double air valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc all complete as directed.for 88.9 mm dia.

1

-

-

... More
Labour charge for cutting DI pipe of different dia for required length as directed for 350 dia

813.26

-

-

... More
Construction of brick masonry valve Chamber in cement mortar 1:5 ( 1 cement: 5 coarse sand ), 100 mm thick RCC top slab with 1:2:4 mix (1 cement :2 coarse sand: 4 grade stone aggregate20 mm nominal size) with 10 mm dia tor steel @ 130c/c both ways (double jali), 100 mm thick foundation concrete 1:3:6 mix (1 cement :3 coarse sand: 4 grade stone aggregate40 mm nominal size) concrete, inside plastering 12mm thick with cement mortar 1:4 (1 cement: 4 course sand) finished with floating coat neat cement complete as per standard design and drawing as directed by the Engineers-In-Charge .b) Size -1200 mm x1200 mm x1200 mm

1

-

-

... More
Supplying & providing of PCC thrust block as per standard design & drawing having concrete mix 1:3:6 ( 1 Cement : 3 Coarsesand :6 Stone Aggregate 40 mm nominal size) having average size 600x600x600 mm

0.86

-

-

... More
Construction of R.C.C. pillar of size 250mm X 250mm with 8 nos 12 dia tor steel and 6 mm dia ties @ 150 c/c with a foundation of size 750X750X200 mm with 10 tor Jali 120C/C both ways with M20 grade concrete over 100 mm thick PCC 1:3:6 concrete including required centering & shuttering and plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement all complete as per standard design for supporting pipe lines at crossing through low land , drain etc.

6

-

-

... More
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level:- Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.N) Without using admixture, plasticiserb) M20 grade concrete or Prop. 1:1.5:3

5

-

-

... More
Form work of Vertical surface such as walls (any thickness), parapet walls, partitions, walls of septic tank, inspection pit and the like including attached pilasters, butresses, plinth and string courses and the like. (ii) Using 25mm thick plank

12.4

-

-

... More
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX)- (For Assam Type Bldg , drain works, retaining wall & boundary wall etc. .

4.5

-

-

... More
Demolishing plain cement concrete including disposal of debris as directed for all levels(ii) Prop (1 : 3 : 6) or richer mix

3

-

-

... More
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels

0.68

-

-

... More
Labour charge for carrying and laying in position in line level Rubber Hose Pipe all complete as directed.(f) 250 mm dia

51

-

-

... More
Providing flanged joints to double flanged C.I. pipes and specials with testing of joints and including supplying bolts, nuts and 3 mm thick rubber insertion sheet all complete as directed. (i) 250 mm dia Each

19

-

-

... More
Labour charge for carrying, placing in position, fitting and fixing C.I. double air valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc all complete as directed.iii) 88.9 mm dia.

1

-

-

... More
Labour charge for carrying, laying in position S&S, flanged, plain ended C.I. Specials such as tees, bends, collars, tappers and caps etc. all complete as directed. Qtl Rs. 110.50

3.5

-

-

... More
D. Clear water pumping main with D.I. pipe

-

-

-

... More
Earth work in excavation in black toping road surface (average thickness of black toping 35mm) including the removal of road metal, boulders and refilling the same properly and restore the road surface to its original condition (except black toping as the black toping to be done by the P W D on necessary payment all complete as directed.for 200mm dia DI pipe

26

-

-

... More
Earth work in excavation for metallic road surface (average thickness of 40 cm) including the removal of road metal, boulders and including restoration of road surface original condition all complete as directed.

26

-

-

... More
Earth in excavation in foundation trenches including refilling the quantity as necessary after completion of works of pipe line dressing, ramming, watering etc. and removal of surplus earth with 50 M lead and lift up to 1.5 M all complete as directed including boiling out water where necessary.b) Bastic land, tillah soil, hard soil, mixed with moram gravel and boulder up to one man size.

19.89

-

-

... More
Labour charge for carrying and laying DI pipes and specials (Class-7) in position, in line and level complete as directed.

50

-

-

... More
Providing joint to DI/S&S pipes including cutting the pipes where necessary and supplying all jointing materials where necessary with testing of the joints all complete as directed. (with 10% extra joint)

11

-

-

... More
Providing rubber gasket joints to C.I. pipes and specials with testing of joints including carriage of the materials but excluding the cost of rubber gasket all complete as directed.

2

-

-

... More
Labour charge for carrying, placing in position, fitting and fixing C.I. sluice valve (with wheel & cap) C.I. refluxe valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc (the tail pieces if required will be paid separately) all complete as directed (one valve and two flanged joints

1

-

-

... More
Labour charge for carrying, placing in position, fitting and fixing C.I. double air valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc all complete as directed.ii) 76.2 mm dia.

1

-

-

... More
Labour charge for cutting DI pipe of different dia for required length as directed.

276.32

-

-

... More
Construction of brick masonry valve Chamber in cement mortar 1:5 ( 1 cement: 5 coarse sand ), 100 mm thick RCC top slab with 1:2:4 mix (1 cement :2 coarse sand: 4 grade stone aggregate20 mm nominal size) with 10 mm dia tor steel @ 130c/c both ways (double jali), 100 mm thick foundation concrete 1:3:6 mix (1 cement :3 coarse sand: 4 grade stone aggregate40 mm nominal size) concrete, inside plastering 12mm thick with cement mortar 1:4 (1 cement: 4 course sand) finished with floating coat neat cement complete as per standard design and drawing as directed by the Engineers-In-Charge .a) Size1000 mmx1000 mmx1200 mm

1

-

-

... More
Supplying & providing of PCC thrust block as per standard design & drawing having concrete mix 1:3:6 ( 1 Cement : 3 Coarsesand :6 Stone Aggregate 40 mm nominal size) having average size 600x600x600 mm

0.43

-

-

... More
Labour charge for carrying, laying in position S&S, flanged, plain ended C.I. Specials such as tees, bends, collars, tappers and caps etc. all complete as directed. Qtl Rs. 110.50

1.1

-

-

... More
E. Carrying, laying, testing and commissioning of existing distribution pipe network interlinking with D.I. pipe for Zone-I

-

-

-

... More
Earth work in excavation in black toping road surface (average thickness of black toping 35mm) including the removal of road metal, boulders and refilling the same properly and restore the road surface to its original condition (except black toping as the black toping to be done by the P W D on necessary payment all complete as directed.for 100 mm dia to 400 mm diameter pipe

1291.29

-

-

... More
Earth work in excavation for metallic road surface (average thickness of 40 cm) including the removal of road metal, boulders and including restoration of road surface original condition all complete as directed.

1291.29

-

-

... More
Earth in excavation in foundation trenches including refilling the quantity as necessary after completion of works of pipe line dressing, ramming, watering etc. and removal of surplus earth with 50 M lead and lift up to 1.5 M all complete as directed including boiling out water where necessary.b) Bastic land, tillah soil, hard soil, mixed with moram gravel and boulder up to one man size.

961.69

-

-

... More
Labour charge for carrying and laying DI pipes and specials (Class-7) in position, in line and level complete as directed.

-

-

-

... More
a)100 Dia DI pipe

800

-

-

... More
b) 150 Dia DI pipe

900

-

-

... More
c) 200 dia DI pipe

300

-

-

... More
d) 250 dia DI pipe

500

-

-

... More
e) 300 dia DI pipe

60

-

-

... More
d) 350 dia DI pipe

5.5

-

-

... More
e) 400 dia DI pipe

70

-

-

... More
Providing joint to DI/S&S pipes including cutting the pipes where necessary and supplying all jointing materials where necessary with testing of the joints all complete as directed.

-

-

-

... More
a)100 Dia DI pipe

161

-

-

... More
b) 150 Dia DI pipe

182

-

-

... More
c) 200 dia DI pipe

62

-

-

... More
d) 250 dia DI pipe

101

-

-

... More
e) 300 dia DI pipe

13

-

-

... More
d) 350 dia DI pipe

2

-

-

... More
e) 400 dia DI pipe

15

-

-

... More
Providing rubber gasket joints to C.I. pipes and specials with testing of joints including carriage of the materials but excluding the cost of rubber gasket all complete as directed.

-

-

-

... More
a)100 Dia

6

-

-

... More
b) 150 Dia

6

-

-

... More
c) 200 dia

4

-

-

... More
d) 250 dia

4

-

-

... More
e) 300 dia

2

-

-

... More
d) 350 dia

2

-

-

... More
e) 400 dia

2

-

-

... More
Labour charge for carrying, placing in position, fitting and fixing C.I. sluice valve (with wheel & cap) C.I. refluxe valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc (the tail pieces if required will be paid separately) all complete as directed (one valve and two flanged joints

-

-

-

... More
a)100 Dia

3

-

-

... More
b) 150 Dia

3

-

-

... More
c) 200 dia

2

-

-

... More
d) 250 dia

2

-

-

... More
e) 300 dia

1

-

-

... More
d) 350 dia

1

-

-

... More
e) 400 dia

1

-

-

... More
Labour charge for carrying, placing in position, fitting and fixing C.I. double air valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc all complete as directed.

-

-

-

... More
i) 63.5 mm dia.

4

-

-

... More
ii) 76.2 mm dia.

3

-

-

... More
iii) 88.9 mm dia.

1

-

-

... More
Labour charge for cutting DI pipe of different dia for required length as directed.

-

-

-

... More
a)100 Dia

69.08

-

-

... More
b) 150 Dia

106.76

-

-

... More
c) 200 dia

138

-

-

... More
d) 250 dia

138.16

-

-

... More
e) 300 dia

100.48

-

-

... More
d) 350 dia

116.18

-

-

... More
e) 400 dia

131.88

-

-

... More
Construction of brick masonry valve Chamber in cement mortar 1:5 ( 1 cement: 5 coarse sand ), 100 mm thick RCC top slab with 1:2:4 mix (1 cement :2 coarse sand: 4 grade stone aggregate20 mm nominal size) with 10 mm dia tor steel @ 130c/c both ways (double jali), 100 mm thick foundation concrete 1:3:6 mix (1 cement :3 coarse sand: 4 grade stone aggregate40 mm nominal size) concrete, inside plastering 12mm thick with cement mortar 1:4 (1 cement: 4 course sand) finished with floating coat neat cement complete as per standard design and drawing as directed by the Engineers-In-Charge .

-

-

-

... More
a) Size1000x1000x1200

8

-

-

... More
b) Size -1200x1200x1200

5

-

-

... More
Supplying & providing of PCC thrust block as per standard design & drawing having concrete mix 1:3:6 ( 1 Cement : 3 Coarsesand :6 Stone Aggregate 40 mm nominal size) having average size 600x600x600 mm

1.94

-

-

... More
Supplying, fitting, fixing, commissioning of ISI marked DI fittings class K-12 conforming to IS 9523-2000 with up to date amendment of required diameter suitable for used with DI spun pipe conforming to IS 8329-2000 of class k-7 pipe along with necessary rubber ring of EPDM quality conforming to IS : 5382-1985Bend, tee, reducer, plug etc

500

-

-

... More
Construction of R.C.C. pillar of size 250mm X 250mm with 8 nos 12 dia tor steel and 6 mm dia ties @ 150 c/c with a foundation of size 750X750X200 mm with 10 tor Jali 120C/C both ways with M20 grade concrete over 100 mm thick PCC 1:3:6 concrete including required centering & shuttering and plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement all complete as per standard design for supporting pipe lines at crossing through low land , drain etc.Pillar length 200 m Average

8

-

-

... More
Demolishing plain cement concrete including disposal of debris as directed for all levels(ii) Prop (1 : 3 : 6) or richer mix

18

-

-

... More
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels

3.15

-

-

... More
Hydraulic testing of C.I./D.I. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position sing water supplied by the contractor. With Rubber Rings

-

-

-

... More
a)100 Dia

5894

-

-

... More
b) 150 Dia

2022

-

-

... More
c) 200 dia

806

-

-

... More
d) 250 dia

890.5

-

-

... More
e) 300 dia

60

-

-

... More
d) 350 dia

263.5

-

-

... More
e) 400 dia

70

-

-

... More
Labour charge for carrying, laying in position S&S, flanged, plain ended C.I. Specials such as tees, bends, collars, tappers and caps etc. all complete as directed.

18

-

-

... More
F. External and Internal electrification at WTP

-

-

-

... More
Wiring for light/fan / call bell point with 2x 1.5 sq. mm PVC insulated single core unsheathed industrial (multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolitic copper conductor for voltage grade upto 1100 volts (R.R Kebel/Finolex/Havells or equivalent Make as approved by the deptt) with flat 19 mm ISI marked casing 'n'capping (AKG/ Precision /Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) in surface system, including 6 Amp flush type switch /bell push (Anchor Penta/Gold Medal/Kolor Kany.com/ Havells or equivalent Make as approved by the deptt) , GI/MS switch board (ISI Marked) half conceale on wall with phenolic laminated sheet cover, Ceiling rose (Anchor/Gold Medal/Kolor Kany.com/ Havells oe equivalent Make as approved by the deptt) etc. complete as directed and as specified by the deptt.

-

-

-

... More
a) Short point upto 3.00 metre length

12

-

-

... More
b) Medium point upto 6.00 metre length

12

-

-

... More
c) Long point upto 10.00 metre length.

6

-

-

... More
Supplying and fixing 18 S.W.G. sheet metal boxes of following nominal size in surface wiring system fitted with suitable size phenolic laminated sheet covers in front face of the boxes including painting etc. as require and as specified by the department

-

-

-

... More
a) 200 mm. x 250 mm. X 60 mm. deep. (Nominal size).

2

-

-

... More
b) 250 mm. x 350 mm. x 60 mm. deep. (Nominal size).

2

-

-

... More
Supplying and fixing of switch/socket on the existing board including connections etc. complete. (I.S.I. approved) (Ref: SOR'10-11-I/No-124 for detailing, new SOR is silent)

-

-

-

... More
6 Amps flush type switch (one way)

24

-

-

... More
16 Amps flush type switch.

2

-

-

... More
3 Pin 6 Amps flush type socket outlets

4

-

-

... More
3 Pin 16 Amps flush type socket outlets.

2

-

-

... More
5 Pin 16 Amps flush type multi switch and socket outlets combined unit.

2

-

-

... More
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolitic copper conductor for voltage grade upto 1100 volts (R.R Cable/ Finolex or equivalent Make as approved by the deptt.) in surface flat ISI marked casing 'n' capping (AKG /Precision/Presto Plast/ Polycab/MW or equivalent make as approved by the deptt.) system including earth continuity-

-

-

-

... More
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm in flat 19 mm ISI marked casing 'n' capping system.

132

-

-

... More
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. in flat 19 mm ISI marked casing 'n'capping system.

120

-

-

... More
Supplying with fitting fixing of CFL/Flourescent luminaries complete with all accessories such as ballast, starter etc. directly on wall/ceilling including connection as approved by the deptt, with 1.5 sq. mm PVC insulated single core copper conductor as reqd. and as directed by the Deptt. Striplite luminaries complete with VPIT copper ballast/electronic balast and decorative end cap and 1 X36/ 40 watt. Flourescent tube. (Crompton Greaves make), Model- DSG1114LDB CROM GOLD/ DSG1114LDBN CROM GOLD NEW / DSG1314EB CG GOLD /DSG 1414 EB PLANET GOLD WITH super saver/super Brite lamp or equivalent ( equivalent will be selected by the deptt considering the mother items rate) PHILIPS/ WIPRO / HAVELS/ HPL/ SOLAR /JAQUAR MAKE.

19

-

-

... More
Supplying, installation, testing and commissioning of following outdoor flood light of LED/MH/HPSV luminaries complete with all accessories such as ballast, capacitor, lamp, ignitor and driver as required complete with necessory support /foundation with 2.5 sqmm PVC insulated single core copper conductor as reqd. and as directed by the Deptt.-- MVC 502 1 xMHNTD-150W Philips make flood light luminaries with cast Aluminium housing and toughened glass cover including seperate CG box or equivalent ( equivalent will be selected by the deptt considering the mother items rate) BAJAJ/ WIPRO / HAVELS/ Crompton / HPL/ SOLAR/ JAQUAR MAKE.

5

-

-

... More
Supplying including installation, commissioning of vermin and dust proof totally enclosed Phosphetised powder painted cubical indoor type floor/wall mounting compartmentalize panel board of size 1.95 M(B) x 1.20 M (H) x 0.40M (0) made of 16 SWG (1.66 MM) thick C.R. sheet and 40mm x40mmx 5 mm size angle having 4 Nos. legs at the bottom. The panal Board is to be erected in 1:3:6 PCC foundation including brick soling/grouting etc. complete neatly wiring done with provision for one no 800 A, 4 pole MCCB or switch fuse unit as incomer and provision for 4 Nos DP or TPN outgoing as specified and as directed by the department conforming to IP-43 protection comprising of the following electrical items: i) 50mm x 10mm 4 strip copper Bus-Bar 1.20 M length each-4 setii) 20mm x 3mm 4 strip copper Bus-Bar 0.50 M length each-4 set2. Digital 3 phase Voltmeter Accuracy class 0.50- 1 Nos3. Digital 3 phase Ammeter Accuracy class 0.50- 1 Nos4. Pilot Lamp with integral Circuit LED 110-230 V (Red, Yellow & Blue)- 3 Nos.5. Voltmeter & Ammeter Selector Switch-2 Nos.6. 2A Slide fuse unit- 3 Nos(Outgoing Switch Gear of reqd. rating will be measured and paid sepately)

1

-

-

... More
Supplying with fitting and fixing panel mounting open execution 50KA 415V 50Hz 4P MCCB with Microprocessor Release (Ics=Icu), adjustable Overload and short Circuit setting , without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. [ABB/ Schneider,/ Legrand/ L&T, Siemens/ Hager C&S Make)- 100 A.

4

-

-

... More
Supplying with fitting and fixing 4P, 10 KA 415V 50Hz MCB of the following capacity complete with making necessary connection as specified and directed by the deptt.- C series [ABB, Schneider MG, Legrand, Hagger, Crabtree Xpro make]- 6 to 32 A

4

-

-

... More
Supplying of vacuum pump starter for 3HP (DOL)

2

-

-

... More
Supplying with fitting and fixing including necessary connection as approved by the department D.O.L Starter (Cromton Greaves/ Control and switch gear/ BCH/L&T/ Siemens Make) of following type and capacity as specified and directed by the deptt. D.O.L starter-25HP, 24 to 39A (2 Nos for CWP & 1 standby)

3

-

-

... More
Supply and laying of following size solid aluminium conductor up to 10 sq. mm balance stranded conductor, XLPE insulated, cores laid up, PVC tape inner sheathed, unarmoured/ Armoured (Aluminium for single core upto 70 sq mm balance aluminium strip), Galvanised for cables upto 2x10 sqmm, 3x10 sqmm,4x6 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650 /1100 V grade as per IS:7908 (Part-1) 1988 laid in air or through existing cable trench /duct /cable tray / HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the depertment (Nicco/ Havells/ RPG/CCI/ Polycab/Gloster / Finolex make or equivalent)-

-

-

-

... More
a) 4 mm2 3 core armoured Cable (panel to external light post 12 nos x 30m av length )

360

-

-

... More
a) 6mm2 3 core armoured Cable (panel to Vaccum pumps)

18

-

-

... More
b) 50.00 mm2 3&1/2 core armoured Cable (panel to 2 Nos of starter for Clear water pumps)

56

-

-

... More
(c) 95 Sq.mm 3 and 1/2 core armoured cable (transformer to Panel Board- 150 Rm+ Panel to CWP1 & CWP2-2x28 Rm)

206

-

-

... More
Supply with installation & commissioning of readymade maintenancefree CPRI approved chemical earthing system with 50MM dia. .00 Metres length corrossion free dualpipe technology G.I. CHEM ROD EELECTRODE complete with RESLOW Grounding Minerals (25KG) and Advance Earth Pit cover (PVC) including excavation of earthpit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.

2

-

-

... More
Supplying and laying of 25x6 mm size G.I. strips drawn of surface from earth electrode to Electrical switch gears, machineries etc. complete with supply of G.I. nuts & bolts, screws etc complete etc. including riveting, soldering & making necessary connection as approved, specified and directed by the department.

60

-

-

... More
Supplying with fitting and fixing of the following integral type street light luminaries complete and consisting of single piece integral opexy gray powder coated dia cast alluminium housing gasket, pot optic reflector, cast alluminium frame from heat resistance toughened clear glass cover and accessories such as Condenser, lamp holder, Balast, lamp etc. in the existing pole including making necessary connection as approved by the deptt. with 2 x 2.50 sq mm F.R multi stand and P.V.C insulated single core copper cable as specified and directed by the department.= Philips make Cat. No-SRP 308 1XSON 70W FG for lamp SON70W /CROMPTON GREAVES make-SSSG12071H/FG FOR LAMP 1X70W HPSV/ HAVELS MAKE-LHRS13170A99 FOR LAMP1X70W SON -E

12

-

-

... More
Supplying including fitting fixing of high speed A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connections etc. as required complete and as directed by the Department [Without regulator].- Standard model 1200mm sweep (Usha make)

11

-

-

... More
Supplying including fitting fixing of Electronic STEP Type Regulator for ceiling fan complete with all connections in the existing board as required complete and as directed by the department.

11

-

-

... More
G. External and internal electrification of Barge

-

-

-

... More
Supplying including installation, commissioning of vermin and dust proof totally enclosed Phosphetised powder painted cubical indoor type floor/ wall mounting compartmentalize panel board of size 1.95 M(B) x 1.20 M (H) x 0.40M (0) made of 16 SWG (1.66 MM) thick C.R. sheet and 40mm x40mmx 5 mm size angle having 4 Nos. legs at the bottom. The panal Board is to be erected in 1:3:6 PCC foundation including brick soling / grouting etc. complete neatly wiring done with provision for one no 800 A, 4 pole MCCB or switch fuse unit as incomer and provision for 4 Nos DP or TPN outgoing as specified and as directed by the department conforming to IP-43 protection comprising of the following electrical items: i) 50mm x 10mm 4 strip copper Bus-Bar 1.20 M length each-4 set,ii) 20mm x 3mm 4 strip copper Bus-Bar 0.50 M length each-4 set, 2. Digital 3 phase Voltmeter Accuracy class 0.50- 1 Nos3. Digital 3 phase Ammeter Accuracy class 0.50- 1 Nos4. Pilot Lamp with integral Circuit LED 110-230 V (Red, YelloW & Blue)- 3 Nos.5. Voltmeter & Ammeter Selector Switch-2 Nos.6. 2A Slide fuse unit- 3 Nos(Outgoing Switch Gear of reqd. rating will be measured and paid sepately)

1

-

-

... More
Supplying with fitting and fixing panel mounting open execution 50KA 415V 50Hz 4P MCCB with Micrprocessor Release (Ics=Icu, adjustable Overload and short Circuit setting , without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. [ABB/ Schneider,/ Legrand/ L&T, Siemens/ Hager C&S Make)- 100 A.

3

-

-

... More
Supplying with fitting and fixing 4P, 10 KA 415V 50Hz MCB of the following capacity complete with making necessary connection as specified and directed by the deptt.- C series [ABB, Schneider MG, Legrand, Hagger, Crabtree Xpro make]- 6 to 32 A

2

-

-

... More
Supplying of vacuum pump starter for 3HP (DOL)

2

-

-

... More
Supplying with fitting and fixing including necessary connection as approved by the department D.O.L Starter (Cromton Greaves/ Control and switch gear/ BCH/L&T/ Siemens Make) of following type and capacity as specified and directed by the deptt. D.O.L starter-25HP, 24 to 39A (2 Nos for RWP & 1 standby)

3

-

-

... More
Supply and laying of following size solid aluminium conductor up to 10 sq. mm balance stranded conductor, XLPE insulated, cores laid up, PVC tape inner sheathed, unarmoured/ Armoured (Aluminium for single core upto 70 sq mm balance aluminium strip), Galvanised for cables upto 2x10 sqmm, 3x10 sqmm,4x6 sqmm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100V grade as per IS:7908 (Part-1) 1988 laid in air or through existing cable trench/duct /cable tray /HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the depertment (Nicco/ Havells/ RPG/CCI/ Polycab/Gloster / Finolex make or equivalent)-

-

-

-

... More
a) 6.00 mm 2.3 core armoured Cable (panel to Vaccum pumps)

18

-

-

... More
b) 50.00 mm2 3&1/2 core armoured Cable (panel to 2 Nos of starter for Raw water pumps)

36

-

-

... More
c) 95 Sq.mm 3 and 1/2 core armoured cable (transformer to Panel Board- 150 Rm+ Panel to RWP1 & RWP2-2x15 Rm)

18

-

-

... More
Supplying and laying of 25x6 mm size G.I. strips drawn of surface from earth electrode to Electrical switch gears, machineries etc. complete with supply of G.I. nuts & bolts, screws etc complete etc. including riveting, soldering & making necessary connection as approved, specified and directed by the department.

30

-

-

... More
Wiring for light/fan / call bell point with 2x 1.5 sq. mm PVC insulated single core unsheathed industrial(multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolitic copper conductor for voltage grade upto 1100 volts (R.R Kebel/Finolex/Havells or equivalent Make as approved by the deptt) with flat 19 mm ISI marked casing 'n'capping (AKG /Precision /Presto Plast /Polycab /MW or equivalent make as approved by the deptt.) in surface system, including 6 Amp flush type switch /bell push (Anchor Penta/Gold Medal/Kolor Kany.com/ Havells oe equivalent Make as approved by the deptt) , GI/MS switch board (ISI Marked) half conceale on wall with phenolic laminated sheet cover, Ceiling rose (Anchor/Gold Medal/Kolor Kany.com/ Havells oe equivalent Make as approved by the deptt) etc. complete as directed and as specified by the deptt.

-

-

-

... More
a) Short point upto 3.00 metre length

3

-

-

... More
b) Medium point upto 6.00 metre length

6

-

-

... More
c) Long point upto 10.00 metre length.

6

-

-

... More
Supplying and fixing 18 S.W.G. sheet metal boxes of following nominal size in surface wiring system fitted with suitable size phenolic laminated sheet covers in front face of the boxes including painting etc. as require and as specified by the department

-

-

-

... More
a) 200 mm. x 250 mm. X 60 mm. deep. (Nominal size).

2

-

-

... More
b) 250 mm. x 350 mm. x 60 mm. deep. (Nominal size).

2

-

-

... More
Supplying and fixing of switch/socket on the existing board including connections etc. complete. (I.S.I. approved) (Ref: SOR'10-11-I/No-124 for detailing, new SOR is silent)

-

-

-

... More
6 Amps flush type switch (one way)

15

-

-

... More
16 Amps flush type switch.

2

-

-

... More
3 Pin 6 Amps flush type socket outlets

1

-

-

... More
3 Pin 16 Amps flush type socket outlets.

1

-

-

... More
5 Pin 16 Amps flush type multi switch and socket outlets combined unit.

1

-

-

... More
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolitic copper conductor for voltage grade upto 1100 volts (R.R Cable/ Finolex or equivalent Make as approved by the deptt.) in surface flat ISI marked casing 'n' capping (AKG/Precision/Presto Plast/ Polycab/MW or equivalent make as approved by the deptt.) system including earth continuity-

-

-

-

... More
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm in flat 19 mm ISI marked casing 'n'capping system.

30

-

-

... More
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. in flat 19 mm ISI marked casing 'n'capping system.

15

-

-

... More
Supplying with fitting fixing of CFL/Flourescent luminaries complete with all accessories such as ballast, starter etc. directly on wall/ceilling including connection as approved by the deptt, with 1.5 sq. mm PVC insulated single core copper conductor as reqd. and as directed by the Deptt.

-

-

-

... More
Striplite luminaries complete with VPIT copper ballast/electronic balast and decorative end cap and 1 X36/ 40 watt. Flourescent tube. (Crompton Greaves make), Model- DSG1114LDB CROMGOLD/ DSG1114LDBN CROM GOLD NEW / DSG1314EB CG GOLD /DSG 1414EB PLANET GOLD WITH super saver/super Brite lamp or equivalent ( equivalent will be selected by the deptt considering the mother items rate) PHILIPS/ WIPRO / HAVELS/ HPL/ SOLAR/JAQUAR MAKE.

10

-

-

... More
Supplying, installation, testing and commissioning of following outdoor flood light of LED/MH/HPSV luminaries complete with all accessories such as ballast, capacitor, lamp, ignitor and driver as required complete with necessory support /foundation with 2.5 sqmm PVC insulated single core copper conductor as reqd. and as directed by the Deptt.-- MVC 502 1 x MHNTD-150W Philips make flood light luminaries with cast Aluminium housing and toughened glass cover including seperate CG box or equivalent ( equivalent will be selected by the deptt considering the mother items rate) BAJAJ/ WIPRO / HAVELS/ Crompton / HPL/ SOLAR/ JAQUAR MAKE.

4

-

-

... More
H. PIPING ARRANGEMENT OF ESR FOR ZONE-1

-

-

-

... More
Supplying of CIDF pipes of Class -B as per relevant latest IS specification as directed by Engineer -In-charge. (As per IS:1537-1976 )

-

-

-

... More
a) 100 mm dia (over flow)

681.2

-

-

... More
b) 200 mm dia. (Pumping inlet )

1596.4

-

-

... More
c) 250 mm dia (delivery line)

1652

-

-

... More
Supplying of C.I.D.F. Sluice valve - Butterfly Valve (Wafer Type) Body S.G. Iron, Without Lugs, Gear Operated, S.S.-304 Disc, Nitrile / EPDM Rubber Lining. Test Pressure PN-10 / PN-16 (Zoloto or Equivalent)(g) 350mm as per relevant latest IS specification as directed by Engineer -In-charge.a) 250 mm dia (delivery and drainout line)

2

-

-

... More
Supplying of CI double flanged following specials such as Tee , Bends , Reducer , Tappers and Caps etc as directed (Unit weight are approx)

-

-

-

... More
250mm dia. Tail piece

140

-

-

... More
250mm dia. 900 bend

130

-

-

... More
250mm dia. Tee

203.85

-

-

... More
200mm dia. Duck foot bend

53

-

-

... More
200mm dia. 900 bend

45

-

-

... More
200mm dia. Flanged spigot

60

-

-

... More
100mm dia. Duck foot bend

18.5

-

-

... More
100mm dia. 900 bend

15.3

-

-

... More
100mm dia. Flanged spigot

19

-

-

... More
Labour charge for carrying, laying vertically G.I./C.I./M.S. pipes and specials and fitting, fixing including centering complete as directed (flanged jointing will be measured and paid separately).

-

-

-

... More
a) 100 mm dia (over flow)

26

-

-

... More
b) 200 mm dia. (Pumping inlet )

26

-

-

... More
c) 250 mm dia (delivery line)

20

-

-

... More
Providing flanged joints to double flanged C.I. pipes and specials with testing of joints and including supplying bolts, nuts and 3 mm thick rubber insertion sheet all complete as directed

-

-

-

... More
a) 100 mm dia (over flow)

14

-

-

... More
b) 200 mm dia. (Pumping inlet )

14

-

-

... More
c) 250 mm dia (delivery line)

12

-

-

... More
Labour charge for carrying and laying in position D.I. / C.I.S. & S S & S flange, Plain ended C.I. specials such as Tee, Bends Collar, Tappers and Caps etc. complete as directed.

6.84

-

-

... More
Labour charge for carrying, placing in position, fitting and fixing CI sluice valve ( with wheel and cap) CI reflex valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc. ( the tail pieces if required will be paid separately) all complete as directed ( one valve and two flanged joints) for 250 mm dia (delivery line)

2

-

-

... More
Construction of brick masonry valve Chamber in cement mortar 1:5 ( 1 cement: 5 coarse sand ), 100 mm thick RCC top slab with 1:2:4 mix (1 cement :2 coarse sand: 4 grade stone aggregate20 mm nominal size) with 10 mm dia tor steel @ 130c/c both ways (double jali), 100 mm thick foundation concrete 1:3:6 mix (1 cement :3 coarse sand: 4 grade stone aggregate40 mm nominal size) concrete, inside plastering 12mm thick with cement mortar 1:4 (1 cement: 4 course sand) finished with floating coat neat cement complete as per standard design and drawing as directed by the Engineers-In-Charge . Size -1200x1200x1200

1

-

-

... More
Supplying & providing of PCC thrust block as per standard design & drawing having concrete mix 1:3:6 (1 Cement : 3 Coarsesand :6 Stone Aggregate 40 mm nominal size) having average size 600x600x600 mm

0.86

-

-

... More
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0 M and removal of the same for insitu reinforced concrete and plain concrete works in : 25 mm thick plank

5.76

-

-

... More
Applying prime coat over new steel and other metal surfaces over 100 mm in girth/ width after preparing the surfaces by thoroughly cleaning oil, grease, dirt and other foreign matterand scoured with wire brushes, fine steels, wood scrapers and sand papering- with ready mixed " Red lead / Red oxide primer

44.72

-

-

... More
Painting two coats ( excluding priming coat) over new steel and other metal surfaces over 100 mm in girth/ width with enamel paint of approved brand and manufacture (Asian paint / Berger paint / ICI paint / J&N paint / Nerolac ) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter.

44.72

-

-

... More
Providing ,fitting, fixing, testing and commissioning of water level indicator, callibrated scale, floating valve, string rope, roller with stand all complete as per standard specification and approved by the Engineer-in -Charge.

1

-

-

... More
Hydrotesting of the ESR with 9.00 Lakh litres of clear water along with all necessary arrangement all complete as per standard specification and approved by the Engineer-in -Charge.

1

-

-

... More
I.Electric driven Centrifugal Raw water pumping set at barge

-

-

-

... More
Supply, installation, testing and commissioning of electrical driven Centrifugal Raw water pumping set (couple type) suitable for operation with 415 (+10 %) V, 3-phase, 50 Hz + 3% power supply with panel board including Star Delta starter (AC incorporating incomer MCCB, three air break contactors for main/ delta/star complete set as required) etc. with suitable size/capacity & following specification of pump/ motor along with all accessories such as base frame, coupling, guard foundation, bends, non return valves, sluice valve, clamps with nuts & bolts, clips etc. in all respect including construction of foundation all complete (excluding suction and delivery mains /pipes, specials, fitting, fixing etc.). Specification: i) Horizontal split casing centrifugal pump type ii) RPM of Motors be 1400 to 1500 iii) Construction materials – cast iron casing, stainless steel shaft, Bronze impeller. Horizontal Split casing centrifugal Pump type Head -30 .00 M RPM -1400 to 1500 Discharge -110 LPS Casing -Cast Iron Shaft -Stainless steel Impeller - cast Iron Length of clear water Pumping Main -1500.00M (including 20% cost index to W.O. value)

1

-

-

... More
Supplying, installation, testing and commissioning of panel Board with star Delta starter along with all accessories etc. as required for the above mention pump sets

1

-

-

... More
Supplying,fitting, fixing of cable for LT connection

30

-

-

... More
Construction of foundation for installation pump and motor

1

-

-

... More
Supplying, including fitting fixing Double flange DI Sluice valve including all accessories for PIN=1.0 conforming to IS 14846/200 for delivery pipe.

1

-

-

... More
Supplying, including fitting fixing DI Horizontal Non return valve including all accessories conforming to IS 5312/200 for delivery pipe.

1

-

-

... More
Supplying, Fitting and Fixing of Specials , Bends

1

-

-

... More
Supply , fitting fixing of Foot Valves

1

-

-

... More
Supply of Suction and delivery Flange

1

-

-

... More
Supplying , placing laying fitting and fixing of suction and delivery GI pipe line (TATA Medium) along with its all accessories / specials like bolts etc. as per requirement in the field for the installation of above mentioned pumping set as per specification-

-

-

-

... More
(a) 200 mm dia

6

-

-

... More
(b) 150 mm dia

6

-

-

... More
Supply, fitting, fixing of Aluminum Armoured cable for power line from Transformer to of Main panel Board to LT Pannel Board including Lugs, and connectors( 70 sqmm x 3 core)

50

-

-

... More
Supplying, fitting, fixing and commissioning with IS marked cast Iron pipe with flaned ended & CI specials and valves and air blower pipe lines for mechancal arrangement of filter unit, clarifloculator and aerator of 10.34 MLD treatment plant complete

-

-

-

... More
Supplying of Centrifugally cast (spun) iron double flange pressure pipes conforming to ISI specification in standard working length.- 250 mm dia.

250

-

-

... More
Labour charge for carrying laying in position cast iron double flanged pipe in line level all complete as directed- b) 250mm dia.

6

-

-

... More
Providing flanged joints to double flanged CI pipes and specials with testing of joints and including supplying bolts, nuts and 3mm thick rubber insertion sheet all complete as directed- of 250mm dia.

4

-

-

... More
Supplying of CI double flanged/socketed specials such as Tee, Bends, Reducer, Tappers and Caps etc for pressure pipe conforming to IS 1538-1993 with upto date amendment as applicable for the various dia as directed

110

-

-

... More
Labour charge for carrying and laying in position D.I. / C.I.S. & S S & S flange, Plain ended C.I. specials such as Tee, Bends Collar, Tappers and Caps etc. complete as directed.

0.11

-

-

... More
Supplying of C.I.D.F. Sluice valve conforming to IS 780:1984 with upto date amendment as applicable for the following dia for PN-1.6 (with wheel and cap).

-

-

-

... More
(i) 80 mm dia.

3

-

-

... More
(ii) 250 mm dia.

1

-

-

... More
Labour charge for carrying, placing in position, fitting and fixing CI sluice valve ( with wheel and cap) CI reflex valve complete with supplying bolts and nuts, 3 mm thick rubber insertion sheet etc. ( the tail pieces if required will be paid seperately) all complete as directed ( one valve and two flanged joints).

-

-

-

... More
(i) 80 mm dia.

3

-

-

... More
(ii) 250 mm dia.

1

-

-

... More
Providing U.P.V.C. threaded plumbing & casing PVC pipes of class IV/10 kg/cm2 threaded plumbing &casing PVC PIPES(Blue/Off White colures) for laterals of filter.-90 mm dia (Lateral)

299.25

-

-

... More
Providing P.V.C. fittings for lateral- a) 90 mm dia. Tee (Fenolex brand)

63

-

-

... More
Providing P.V.C. fittings for lateral- b) Providing End Cap for laterals.(Fenolex brand)

126

-

-

... More
Providing 12mm dia. hole for lateral @ 215mm c/c and fitting, fixing over the filter bed as directed

1449

-

-

... More
Supplying, fitting, fixing of GI medium pipe (Nezone) medium for connecting to air blower.-100 mm dia.

42.85

-

-

... More
Providing G.I.Specials ( Air blower line)- 100 mm dia. Tee

3

-

-

... More
Providing G.I.Specials ( Air blower line)- 100 mm dia. Union socket

6

-

-

... More
Providing G.I.Specials ( Air blower line)-100 mm dia. Elbow

9

-

-

... More
Providing G.I.Specials ( Air blower line)-100 mm dia. 900 bend

9

-

-

... More
Providing G.I.Specials ( Air blower line)-100 mm dia. Socket

15

-

-

... More
Providing G.I.Specials ( Air blower line)-100 mm dia. 6'' nipple

15

-

-

... More
Providing G.I.Specials ( Air blower line)- 100 mm dia full way valve.

4

-

-

... More
Supplying, fitting fixing of 32mm dia M.S. spindle of 4.00m long, required bushing, Head stock stand

6

-

-

... More
Construction of brick masonry valve Chamber in cement mortar 1:5 ( 1 cement: 5 coarse sand ), 100 mm thick RCC top slab with 1:2:4 mix (1 cement :2 coarse sand: 4 grade stone aggregate20 mm nominal size) with 10 mm dia tor steel @ 130c/c both ways (double jali), 100 mm thick foundation concrete 1:3:6 mix (1 cement :3 coarse sand: 4 grade stone aggregate40 mm nominal size) concrete, inside plastering 12mm thick with cement mortar 1:4 (1 cement: 4 course sand) finished with floating coat neat cement complete as per standard design and drawing as directed by the Engineers-In-Charge .b) Size -1200x1200x1200

4

-

-

... More
Supplying, installation, testing and commissioning of 25 HP capacity Air Blower and 3 Nos Electrically driven agitators for Alum/Lime/ flash mixer with all accessories for Sivasagar Town Water Supply Scheme

-

-

-

... More
Supplying, installation, testing and commissioning of Kay International make Air Blower Compressor Model-610 AC Motor Make- Marathon/Kirloskar, Rating-25 HP, Capacity-555 Cum/hr pressure-0.35 Kg/Sqm, RPM-1440 with panel board, starter & other controls Sl No. 16061162 STB 6/8/equivalent as per requirement of the scheme as directed by the the Engineer-in -charge.

1

-

-

... More
Supplying, installation, testing and commissioning of ISO marked Agitators for Alum Tank, Lime tank and flush mixer with MSEP base frame support to suit client's tank comprising of the following: (i) Geared motor of 100 rpm approx. output speed with TEFC prime motor suitable for 415 V, 3 phase, 50Hz A.C supply-IP-55 construction- Class F-insulation. (ii) Output coupling assembly in CI construction. (iii) Solid shaft with pitch blade Turbine/propeller type impeller in SS 304/ SS316 construction. (iv) Operating speed of the Mixer Impeller. Approx- 100 rpm.. ( Rates included 20% as freight & installation charge)

-

-

-

... More
(a) Agitators for Alum tank: 1.0 Mx 1.0 Mx1.20 M SWD+ 0.50 FB (SS316)

1

-

-

... More
(b) Agitators for Lime tank: 1.0 Mx 1.0 Mx1.20 M SWD+ 0.50 FB (SS 304)

1

-

-

... More
(c ) Agitators for Flash Mixer: 2.10 Mx 2.10 Mx1.20 M SWD+ 0.50 FB (SS316)

1

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. per litre 9.70= 4000 litre - 3 nos

12000

-

-

... More
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary ‘R’ brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (A) Exposed on walls a) 50 mm dia (Medium) i) Using Tata make

80

-

-

... More
a) 20mm dia (Medium) TATA make

20

-

-

... More
b) 15 mm dia (Medium) i) Using Tata make

10

-

-

... More
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Essco make (Delux/Sumthing spl./Tropical) (i) 15mm dia Bib Cock-item code: DLX-ESS-511

7

-

-

... More
Supplying fitting and fixing chrome plated (C.P.) stop cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) -Jaquar (i) 15mm dia REDUCED BODY OF CONCEALED STOP COCK SUIT, Cat. No.ALD-CHR-069

7

-

-

... More
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. -50 mm dia

2

-

-

... More
J. Supplying and placing of Filter media at filter house

-

-

-

... More
Supplying of river gravel of different size for using as filter media free from dirt, dust or any foreign materials including inorganic salts etc. having the following range of size as directed by EIC a) Gravel s size and depth:

-

-

-

... More
40 to 50 mm size : 200mm

17.39

-

-

... More
32 to 40 mm size : 200mm

17.39

-

-

... More
12 to 20 mm size : 100mm

8.69

-

-

... More
6 to 12 mm size: 100mm

8.69

-

-

... More
Supplying coarse sand to use as filter media for rapid gravity filter effective size from 0.45mm to 0.70 mm and uniformity co-efficient between 1.70 and 1.80 all complete as directed by EIC. The sand shall be hard and reistant quartzite and free from dust, clay and fine particles etc.

52.16

-

-

... More
Labour charge for placing filter media into filter unit in layer by layer after properly screening and washing . Gravel s size and depth:

-

-

-

... More
40 to 50 mm size : 200mm

17.39

-

-

... More
32 to 40 mm size : 100mm

17.39

-

-

... More
12 to 20 mm size : 100mm

8.69

-

-

... More
6 to 12 mm size: 100mm

8.69

-

-

... More
K. Road Restoration for laying water distribution pipe network

-

-

-

... More
Construction of Subgrade and Earthen Shoulders (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table (300-2) (a), ( Including cost of testing of materials at site and laboratory as directed by the deptt.)- (b) For Govt. land

500.97

-

-

... More
By Mix in place method:-Construction of granular sub-base by providing well graded material, spreading in unifrom layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with three wheel 80-100 KN Static roller to achieve the desired density, complete as per techenical specifaction clause 401.(ii) including cost of testing of materials at site and laboratort as directed by the Department- For grading-II materials,Paver block road

3431.5

-

-

... More
Water Bound macadam Providing laying spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in unifrom thickness, hand packing, rolling with vibratory roller 80-100 KN in stages to proper grade and camber, applying and brooming requisite type of screening/binding materials to fillup the interstices of coarse aggregate watering and compacting to the required density. (With an initial lead of 5.0 Km)Grading -III,Paver block road

165.75

-

-

... More
Labour charge for handling laying of Paver Block including sand spreading, leveling & compecting, cutting the edge etc. as directed by the Department , Paver block road

1989

-

-

... More
Providing and laying interlocking concrete block pavement (ICBP) conforming to IS: 15658 -2006 including all lead and lift complete as per technical specification and as directed. -80 mm thick interlocking precast Blocks having compresive strength of 40N/Sq.mm,Paver block road

221

-

-

... More
J. Main Load Distribution Board along with power cable from tranformer and to the LT panal at Barge

-

-

-

... More
Supplying installation testing and commissioning of control panel of the with following features and comprising the following accessories. 3 segment control panel.The enclosure system shall be modular in nature with bolt on construction. Rugged, corrosion-resistant enclosures, made of hot-dip galvanized sheet steel according to standards: ISO 1461, IEC 60439-1and IEC 60439-5 for environment classed C1 and C2 to, ISO 12944-2.All below-ground parts have heavy-duty corrosion protection. To ensure an attractive and functional installation in the ground, A marking label indicates the ground level. With this type of installation, consideration must be given to the risk of condensation, dust, vibration and impacts. The ability of the enclosure to withstand external blows and impacts has been checked by testing at–50° C in accordance with the requirements for use in an Arctic climate in IEC 60439-5.The enclosure should have locking arrangement. All our panels will be of Free standing, Floor mounted, Compartmentalized, Single Front, Non-draw out type, Indoor, IP65 Degree of Protection, Form-3b segregation of Main LT Panels ,  All segregation shall be achieved by means of rigid metallic sheet partitions. All doors, bold on cover, partitions, mounting plates and metallic shrouds shall be effectively connection as approved by the Deptt.ted to earth, Main distribution boards shall be designed for front access for the purpose of operation and access to all components and shall rear access for cable connection as approved by the Deptt.)and top or bottom for cable entries.,The fault level rating of the busbar system shall be with minimum short circuit withstand capacity of 50KA RMS for 1second, ACBs will be of type with microprocessor release with LSIG Protection.,The Panels will be suitable for 3 Phases 4 cable, 415V, 50Hz system, As per our product standard paint shade will be Light Grey RAL 7035. A fairly uniform coating of at least 70-80 microns shall be provided , All floor mounted panels will be supplied with ISMC 100 channel, Electrolytic grade Aluminium Busbar of current density 0.8A/sq. mm. has been considered,   Panels are suitable for both Bottom/Top cable entries as required.All switchgears, quantities, metering & indication accessories are as per attached BOQ,Enclosure shall be readily suitable for future extension on either side without any modifications (after installation at sit."INCOMER- 630A 4P , ACB, FUSE 2A WITH FUSE BASE , Type OFFN1GG2 , make) ABB or equivalent 9 nos , INDICATING LAMP-YELLOW,240VAC(H2) , make) TEKNIC or equivalent 1 no , INDICATING LAMP-BLUE,240VAC(H2) , make) TEKNIC or equivalent 1no , INDICATING LAMP-GREEN,240VAC(H2) , make) TEKNIC or equivalent 1no , MULTIFUNCTION METER WITH RS 485 Communication 1no ,35KA 3P + N SURGE ARRESTOR 1no ,125A 4P D CURVE MCB 1no , DISCONNECTING TERMINALS , make) CONNEC CONNECTWELL or equivalent, make) 7nos , CONTROL TB'S-2.5SQ.mm , CONNECTWELL or equivalent 50nos , OUTGOING: 160A,4P,MCCB,25KA, MCCB,FP, 160A,25KA, THERMAL MAGNETIC RELEASE , Type T1C 160/4P/TMD R160 , make) ABB or equivalent 4nos , EXTENDED ROTARY HANDLE , Type 1SDA070207R1 4nos , REAR TERMINAL 4nos , INDICATING LAMP-YELLOW,240VAC(H2) , make) TEKNIC or equivalent 4nos , INDICATING LAMP-BLUE,240VAC(H2) , make) TEKNIC or equivalent 4nos , FUSE 2A WITH FUSE BASE , Type OFFN1GG2 , make) ABB or equivalent 12nos , OUTGOING: 63A,4P,MCCB,25KA, MCCB,FP, 63A,25KA, , Type T1C 160/4P/TMD R63 , make) ABB or equivalent 1no , EXTENDED ROTARY HANDLE , Type 1SDA070207R1 1no , INDICATING LAMP-RED,240VAC(H1) , make) TEKNIC or equivalent 1no ,INDICATING LAMP-YELLOW,240VAC(H2) , make) TEKNIC or equivalent 1no , INDICATING LAMP-BLUE,240VAC(H2) , make) TEKNIC or equivalent 1no , FUSE 2A WITH FUSE BASE , Type OFFN1GG2 , make) ABB or equivalent 3nos , OUTGOING: 40A,4P,MCCB,25KA, MCCB,FP, 40A,25KA, , Type T1C 160/4P/TMD R40 , make) ABB or equivalent 4nos , EXTENDED ROTARY HANDLE , Type 1SDA070207R1 4nos , INDICATING LAMP-RED,240VAC(H1) , make) TEKNIC or equivalent 4nos , INDICATING LAMP-YELLOW,240VAC(H2) , make) TEKNIC or equivalent 4nos , INDICATING LAMP-BLUE,240VAC(H2) , make) TEKNIC or equivalent 4nos, FUSE 2A WITH FUSE BASE , Type OFFN1GG2 , make) ABB or equivalent 12nos , OUTGOING: 32A,4P,MCCB,25KA, MCCB,FP, 32A,25KA, , Type T1C 160/4P/TMD R32 , make) ABB or equivalent 1no , EXTENDED ROTARY HANDLE , Type 1SDA070207R1 1no , INDICATING LAMP-RED,240VAC(H1) , make) TEKNIC or equivalent 1no , INDICATING LAMP-YELLOW,240VAC(H2) , make) TEKNIC or equivalent 1no , INDICATING LAMP-BLUE,240VAC(H2) , make) TEKNIC or equivalent 1no , FUSE 2A WITH FUSE BASE , Type OFFN1GG2 , make) ABB or equivalent 3nos , Commissioning assistance will be provided by Co. Inspection will be offered by Co. Assembly, Testing of Panels will be done under supervision of ABB Engineers. ,MLDB of required load

1

-

-

... More
Supplying, installation, testing and commissioning of following outdoor flood light of LED/MH/HPSV luminaries complete with all accessories such as ballast, capacitor, lamp, ignitor and driver as required complete with necessory support /foundation with 2.5 sqmm PVC insulated single core copper conductor as reqd. and as directed by the Deptt.-- MVC 502 1 xMHNTD-150W Philips make flood light luminaries with cast Aluminium housing and toughened glass cover including seperate CG box or equivalent ( equivalent will be selected by the deptt considering the mother items rate) BAJAJ/ WIPRO / HAVELS/ Crompton / HPL/ SOLAR/ JAQUAR MAKE.

-

-

-

... More
b) 50.00 mm2 3&1/2 core armoured Cable (panel to 2 Nos of starter for Clear water pumps)

80

-

-

... More
(c) 95 Sq.mm 3 and 1/2 core armoured cable (transformer to Panel Board- 150 Rm+ Panel to CWP1 & CWP2-2x28 Rm)

100

-

-

... More
Supplying and laying of 25x6 mm size G.I. strips drawn of surface from earth electrode to Electrical switch gears, machineries etc. complete with supply of G.I. nuts & bolts, screws etc complete etc. including riveting, soldering & making necessary connection as approved, specified and directed by the department.

60

-

-

... More
K. Drawing of Power line and sub-station at BARGE Site and Treatment Plant site

-

-

-

... More
Drawing of Power line and sub-station at BARGE Site and Treatment Plant Site :Design, supply, erection, testing and commissioning of all Electrical works for Construction of 11 KV line and 11Kv/0.4 KV as required KVA at intake station (Barge ) and Treatment Plant site including , electric cables, Transformer, MCC panel, earthing, Cable trench, Cable tray, Gland and lugs, including drawal of electrical power line from the nearby APDCL Grid, setting up of required capacity 2 nos Sub-Stations , providing electrical control panel & metering units, deposite of Load Sanction amount payble to APDC on behafe on employer etc. and also including obtaining necessary approval from APDCL, payment of supervision & other charges to APDCL, if any, all complete, as specified & directed and all other associated works as per Employer's Requirements as per provisional extimate submited by APDCL at Annexure-I. Note: Power connection will be provided by APDCL authority. Actual amount payable for power connection need to be deposited to the APDCL on behalf of Employer during the execution of the project. Rate should be included amount payable for power connections with all tax payable deducted at source by Employer in all respect.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.