BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 48,500Document Cost
₹ 2,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_TEZU_797268_1Tender No
TU/EC/CIVIL/438/2023-24 Dated 23-02-2024Tender Authority
Tezpur University ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Acoustic Treatment of Walls with Kerf edged Wall Panels Supply and Installation of Kerf edge Fabric wrapped pinewood fiber panels of size 600x2400x20mm of selected colours (ref colour chart) having density 400Kgs/m3, weight 8kg/m2 installed by using GI strut system.The GI strut works includes Cross channel (CC22/10) having thickness 0.45mm, length 3600mm, knurled web 40, depth 22mm and equal flanges of 13mm is fastened to Wall positioned horizontally in a regular manner at 600mm centers. PVC Vinyl core UV treated H-Spline having thickness 2mm and length 2400mm to be fixed perpendicular to the Cross channels (CC22/10) at 600mm centers. Kerfed edge fabric wrapped panels shall be then inserted into the H-spline against wall to perfect fit. Panels shall be backlined with acoustical infill of Anutone Synth PF 5x25mm thick adhered to the wall using Stick 7 adhesive. Technical Parameters • Core Variants - pinewood fibre
• Fire – Class 1 & P • Acoustics – NRC 0.95 • Climate (OC RH) – 50, 90 • Termite resistance – Yes • Light reflectance – color dependant • Green (RC %) – 10 • Hygiene (VoC, Clean room) – Low • Strength, Load capacity (Kg) - Ball impact Anutone / Hera Design / Saint Gobain
74
-
-
WALL PANELING (LOWER PORTION)
-
-
-
Acoustic Treatment with Wall Slats Supply & installation of Slats made of pinewood E1 grade fiberboard, Melamine laminated finish, groove perforated slats L16-2 - (2mm Slats @16mm pitch) / L32-2 - (2mm grooves @ 32mm centers), backlined with black acoustical fleece, tongue-groove edge for a seamless look, of size 128x2440x16mm thick having base density 800Kg/m3, weight 12Kgs/m2 installed by using GI strut system. The GI strut system includes GI Cross channel (CC10) having thickness 0.45mm, length 3600mm, knurled web 40mm, depth 10mm and equal flanges 15mm is fastened vertically/horizontally at every 600mm centers. Aluminium core cross channel (CC18) having thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge & centre brackets is then fixed perpendicular to the CC10 with the help of fasteners at every 400mm centers. Slats of size 128x 2430x16mm in then fixed perpendicular to CC18 with suitable edge & centre brackets. Contractor to provide expansion joints of 3mm at every 5mtrs bothways.Optional: Panels shall be backlined with acoustical infill of 5x25mm thick adhered to the wall using Stick 7 adhesive. Technical Parameters: • Core Variants - Pinewood E1 Fibreboard
• Fire – Class 1 & P • Acoustics – NRC upto 0.75 • Climate (OC RH) – 50, 70 • Light reflectance – 75% (beech haya) • Green (RC %) – 25 • Hygiene (VoC, Clean room) – Low, Class 1 • Strength, Load capacity (Kg) - Ball-Impact Anutone / Hera Design / Saint Gobain
39
-
-
CEILING ACOUSTICS
-
-
-
Acoustic Treatment of Ceiling with Square Edge Acoustic Panels Supply and Installation of Subtex Nubby square edge Glass fibre core fully encapsulated ceiling tiles of size 595x595x15mm having density 100-120Kgs/m3, weight 1.5-1.8kg/m2 which is suspended by using 0.3mm thick and 15mm wide pre coated metal T15 grid system. The T15 Grid system of 600x600mm module shall include wall angle (WA15W30) with unequal flanges of size 14&20mm wide, length 3000mm, 0.43mm thick fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the Main T15 (MT15W36) having flange width 15mm, height 32mm and length 3600mm from the soffit with help of soffit cleat and wire rod with leveling spring clip at 1200mm c/c. Cross T15 (CT15W12) having flange width 15mm, height 32mm and length 1200mm is then interlocked into the pre-cut slots in the Main T15 at 600mm centers in the direction perpendicular to the MainT15. Subtex Nubby square edge of size 595x595x15mm thick shall be placed into the grid size of 600x600mm. Ensure arrow marks behind subtex panels are oriented in one direction to achieve uniform shade. Technical Parameters: • Core - Glassfibre
• Fire – Class 1 & P • Acoustics – NRC 0.9 • Climate (OC RH) – 40, 95 • Termite resistance – Yes • Light reflectance – Low • Green (RC %) – 35 • Hygiene (VoC, Clean room) – Low, Class 3 • Strength, Load capacity (Kg) - Antisag Anutone / Hera Design / Saint Gobain
54
-
-
FLOOR CARPETING
-
-
-
Supply and Installation of Durable Carpet that passed Flamibility Pill Test, made with Dyed Solution Fibre having Plain Loop Pile Construction, made out of 1/10 Gauge Polypropylene Yarn with Primary Backing out of Woven PP and secondary Backing Action Back generating Parmanent Static Control complete with 4mm Packaging Black EPE Foam for Insulation and Comfort Donaire / Traveller / Atelier
60
-
-
ELECTRICAL WORKS
-
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
-
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
105
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
16
-
-
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
75
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
1
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole (10A& 20A)
10
-
-
Triple pole
2
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mm X 150mm)
20
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
-
-
-
5/6 A switch
60
-
-
3 pin 5/6 A socket outlet
60
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
60
-
-
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2
-
-
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
2
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1
-
-
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
30
-
-
LAN WORKS
-
-
-
24 Port Unmanged Switch - Unmanaged/Webmanaged
- 24 x 1G Copper Ports
- 4 x SFP Ports
- Switching Capacity 56Gbps non-blocking
- Forwarding Rate 41.66 Mpps
- Security Feature : ACL , RADIUS , AAA, STORM CONTROL , PORT SECURITY, VLAN
- Management Protocol: IPV4 HTTP , GUI , SNMP , TELNET , SSH .HTTPS , VLAN , RMON
- QoS: SP , WRR , COS , DSCP , LLDP , RATE LIMIT , FLOW CONTROL
- IPv6 Ready from day one and duly certified - Warranty 1 Year
1
-
-
Data Information Outlet '- Cate 6 Information outlet with faceplate conforming to ANSI/TIA/EIA-568 C.2 latest or ISO/IEC:11801 latest
- Tooless temination
- RJ45 Connector type
- preferably tooless
20
-
-
24 Port Patch Panel ' - Cat 6 patch Panel conforming to ANSI/TIA/EIA-568 C.2 latest or ISO/IEC:11801 latest - Suitable for CAT 6 U/UTP
- 1 U height
- 24 No. of Ports
- with rear side cable manager
- made with cold rolled steel
- preferably tooless
1
-
-
Patch Cord 1Mtr '- Cat 6 patch cord conforming to ANSI/TIA/EIA-568 C.2 or ISO/IEC:11801 latest - Length 1Mtr
- Colour Blue
20
-
-
Patch Cord 2Mtr '- Cat 6 patch cord conforming to ANSI/TIA/EIA-568 C.2 or ISO/IEC:11801 latest - Length 2Mtr
- Colour Grey
20
-
-
Cat 6 UTP Cable '- Cate 6 cable conforming to ANSI/TIA/EIA-568 C.2 latest or ISO/IEC:11801 latest
- Type CAT6 S/FTP
- With Flame retardant Outer Sheath
- Colour Grey
- Conductor Diameter 0.57 mm (23 AWG)
- Roll length 305 Mtrs
305
-
-
Installation ' - Surface installation of Cat 6 UTP cable with appropriate size Cap on Casing Conduits - Fixing Information of Outlets and cable termination
- Fixing of Patch Panel and cable termination
- Cable Testing
305
-
-