Tata Memorial Centre Tender

... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Tata Memorial Centre Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date7 Feb 2025
Closing Date22 Feb 2025
Tender Amount₹ 1,04,19,993 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
100mm dia. (32 mm thick insulation)

80

-

-

... More
80mm dia. (32 mm thick insulation)

80

-

-

... More
INSULATED VALVES

-

-

-

... More
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications

-

-

-

... More
Butterfly valve (manual) with CI body, SS disc, nitrile rubber seal & O- ring, PN 16 pressure rating for chilled water circulation as specified

-

-

-

... More
100mm dia

2

-

-

... More
80mm dia

10

-

-

... More
65mm dia

6

-

-

... More
NON RETURN VALVE

-

-

-

... More
NON RETURN VALVE with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.

-

-

-

... More
65 mm dia.

3

-

-

... More
Y strainer

-

-

-

... More
Y strainer of ductile CI body flanged ends with stainless steel strainer for chilled water circulation including insulation as specified.

-

-

-

... More
80mm dia

2

-

-

... More
65mm dia

3

-

-

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required.

8

-

-

... More
Providing and fixing in position the mercury in glass industrial type thermometers complete as required.

8

-

-

... More
SITC of following sizes electronic,self balancing, pressure independent type dynamic balancing valve with integrated 2 way modulating control valves in a single body together with room thermostat. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system with inputs from installed room thermostat. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and not be less than 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimum.

-

-

-

... More
80 mm dia.

2

-

-

... More
DUCTING , GRILLES & INSULATION

-

-

-

... More
Fire Dampers

-

-

-

... More
Supply,Fixing, testing & commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored.The spring return action shall be in built mechanism and not externally mounted.The damper shall also be closed in the event of fire signal complete as required and as per specifications.

-

-

-

... More
Fire Damper

6

-

-

... More
Actuator

8

-

-

... More
Supply & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

1

-

-

... More
Supply & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers as per specifications.

2.5

-

-

... More
Supply, fixing testing commisioning of Supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

12

-

-

... More
Supply, fixing testing commisioning of Return air diffusers of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removable core.

12

-

-

... More
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubbergaskets,nuts,bolts,screws linkages,flanges., as per specifications.

6

-

-

... More
Cable Tray

-

-

-

... More
Supply and installing following size of perforated painted with powder coating M.S Cable trays with perforation not more than 17.5% , in convinient sections , joined with connectors, suspended from the ceiling with M.S suspenders including bolts & nuts , painting suspenders etc as required.

-

-

-

... More
150mm x 50mm x 1.6 mm thick

-

-

-

... More
300 mm x 50 mm x 1.6 mm thick

-

-

-

... More
450 mm x 62.5 mm x 2.0 mm thick

-

-

-

... More
600 mm x 62.5 mm x 2.0 mm thick

-

-

-

... More
Option ECO+ - INTERNAL DUCTING SYSTEM

-

-

-

... More
Supply & Installation of Factory Pre-cut SMART Pre-Insulated ECO+ PIR Panels complete CFC & HCFC Free 20mm thick with FSK Reinforced Aluminium foil on one side and 80 micron Embossed Aluminium foil (Anti microbial, Anti fungal, Anti corrosion and UV Protection coating) on the other side and close cell not less than 95% Rigid Cellular foam insulation of thickness as specified below and material shall be Class O as per BS 476 Part 6 & Part 7 with 2 hours fire rating, with Density of 45(+-3)kg/m3 and should have Thermal Conductivity 0.023 W/mK , Water absorption shall be not more than 0.03% as per EN 13403 standard and panel should be GreenPro & GRIHA certified. The ductwork should be capable of handling pressures upto 2000 Pascals. The joint between the ducts shall be with Polymer slide in type joint between the ducts and all other polymer accessories to be of the same manufacturer. Measurement would be done on outer to outer. Supporting of Threaded Rod (6mm) & C Channel/ Wire supporting of reputed make recommended by Manufacturer to be provided. Manufacture should have minimum 10 years of experience in manufacturing of same product in India. Make: Asawa, AURA, Stiferite

-

-

-

... More
20 mm Thickness (Internal Ducting)

932

-

-

... More
EXTERNAL DUCTING SYSTEM

-

-

-

... More
Supply & Installation of Factory Pre-cut SMART Pre-Insulated PIR Panels complete CFC & HCFC Free 20mm thick with 80 micron Embossed Aluminium foil on the inner side and 200 micron Embossed Aluminium foil (Anti microbial, Anti fungal, Anti corrosion and UV Protection coating) on the other side and close cell not less than 95% Rigid Cellular foam insulation of thickness as specified below and material shall be Class O as per BS 476 Part 6 & Part 7 with 2 hours fire rating, with Density of 45(+-3)kg/m3 and should have Thermal Conductivity 0.023 W/mK , Water absorption shall be not more than 0.03% as per EN 13403 standard and panel should be GreenPro and GRIHA certifed. The ductwork should be capable of handling pressures upto 2000 Pascals. The joint between the ducts shall be with polymer slide in type joints with Patented Gasketed Bayonet and Special Reinforced tape on the joints. All polymer accessories to be of the same manufacturer. Measurement would be done on outer to outer. Supporting should be as per site requirement.Manufacture should have minimum 10 years of experience in manufacturing of same product in India. Make: Asawa, AURA, Stiferite

-

-

-

... More
20 mm Thickness (Internal Ducting)

51

-

-

... More
Modular chilled water units

-

-

-

... More
Supply and commissioning of AHRI crtified air cooled fix speed modular chilled water units each complete with cooling capacity of 37 TR with multiple scroll compressors within one unit, insulated evaporator, flow switch at evaporator, standard spring vibration isolators, integral refrigerant and should be with electronic expansion valve for precise temperature control and power / control cabling from starter to unit, BMS interface unit with all required hardwares and softwares (optional), Victaulic grooved couplings for cooler water in/out connections, control panel, complete charge of refrigerant and oil, accessories as required and called for, automatic and safety control mounted in micro-processor based console panel and all mounted on a steel frame complete as per specifications etc. The drive motor shall be suitable for 415 +/- 10% V, 50 cycles, 3 phase AC supply and motor cable terminal box shall be suitable to connect Aluminium / copper cabling. The chiller will be sharged with R410A refrigerant. The refrigerant circuit shall include a discharge service ball type isolation valve, dual high side pressure relief valves, liquid line shutoff valve with charging port, dual low side pressure relief valves, solenoid valve, electronic expansion valves, and flexible refrigerant receiver, discharge liquid separator and R410 A refrigerant. The unit should meets ASHRAE 90.1-2022 for both full and part load efficiencies. Modular design with an ability to mix and match combinations (inverter+fixed) upto 16 connected chillers. They can operate in master and slave configuiration mode through single controller.

-

-

-

... More
The chiller evaporator should be Brazed Plate Heat Exchanger (BPHE) type made entirely of stainless steel, with direct - expansion and counter - flows. The heat exchange surface is configured so as to maximize the exchange coefficient with minimal load losses. Capable of refrigerant working pressure of 650 psig.

-

-

-

... More
Air cooled condenser with integrated fin and tube coils with inner grooved copper tubes and expanded into aluminimum fins and complete with sub cooler and top discharge air circulators using axial flow fans ith IP protection for outdoor duty, U shaped condenser coil guard etc.

-

-

-

... More
Note: Fins and copper tubes of air cooled condenser along with ciopper tubing / piping with all joints and U bends exposed to coastal areas / corrosive atmosphere / aggressive ambient, shall be painted with special corrosion prevention coating either in factory or at site.

-

-

-

... More
The compressor motor shall be with fixed driven and with protection for under voltage, over load, earth fault and single phasing, integrated thermal protection, oil valve and by pass line, Anti vibration supports etc. It should have differential pressure switch, chilled water temperature sensors, water flow sensors / flow switches etc. Compressor motor overloads capable of monitoring compressor motor current. Provides extra protection against compressor reverse rotation, phase loss, and phase imbalance. Motor overheat protection will be provided to ensure the motor reliability.

-

-

-

... More
The controller should be intelligent & shall have following control facilities.

-

-

-

... More
1. Modular chiller with 7 - inch touch screen, the interface is clear and easy to operate. The entire module should be functional through single controller without any manual intervention - 16 nos single controller & provision to add future expansion.

-

-

-

... More
2. The schedule management mode can set the unit to automatically turn on/off by week or day.

-

-

-

... More
3. Self - restart function after power recovery. Customers can choose to activate this function by their needs, in case of accidental power off failure, the system will automatically record the operating mode before power off and restore the original mode after power restoration.

-

-

-

... More
4. Perfect self-diagnosis function, clear view of vault query to help maintenance quickly solve problems.

-

-

-

... More
5. All day nosie reduction mode or night reduction mode can be selected. The fan speed can be intelligently adjusted to create a comfortable and quiet environment.

-

-

-

... More
Actual cooling capacity at designed conditions indicated below:

-

-

-

... More
Ambient temperature: 95° F

-

-

-

... More
Refrigeration capacity: 37TR

-

-

-

... More
Chiller max area: 2.42 sq. mtr to meet the existing space available

-

-

-

... More
Chilled water leaving temperature: 44° F

-

-

-

... More
Chilled water entering temperature: 54° F

-

-

-

... More
Fouling factor (FPS): 0.0005 ft2.h.oF/Btu

-

-

-

... More
Maximum power consumed at design conditions not greater than 1.16 in iKw/TR @ 100%

-

-

-

... More
System minimum COP at 100% load : 3.0

-

-

-

... More
System minimum IPLV : 4.0

-

-

-

... More
Sea freight and transit insurance upto nearest Kolkata port for th above package.

-

-

-

... More
Clearing the goods from the nearest Kolkata port including customs clearance, local

-

-

-

... More
Make - Daikin / Trane/ Carrier/ York

2

-

-

... More
CHILLED WATER PUMPS

-

-

-

... More
SITC of verticle inline type centrifugal chilled water pump set capable of delivering 90 USGPM of water.

-

-

-

... More
a) 1 no. - Pump with bronze impeller, SS shaft, CI body and mechanical seal.

-

-

-

... More
b) Duly insulated with 19 mm thick, 32 kg/cum density close cell nitrile rubber insulation cladded with aluminium sheets of 0.5 mm thickness and properlly clamped to pump in two semi-circular sections as per specifications.

-

-

-

... More
c) 1 no. suitable HP, TEFC squirrel cage induction motor with class F insulation (IE-2), 1450 RPM synchronous speed, operating on 415 +/- 10% volts, 3 phase, 50 Hz A.C. supply. Minimum efficiency

-

-

-

... More
d) CI/GM casing and gunmetal bronze impeller, Pump shaft SS rating PN - 16 Flush line braided SS, Outside balanced mechanical seal, SS springs and along with double sphere flexible connectors with flange for pipe connection etc. 90 USGPM of water 25 M head ( 2 Working + 1 Standby)

3

-

-

... More
EXPANSION TANK

-

-

-

... More
SITC of open type expansion tank of MS construction made of 6mm thick MS duly insulated with 50 mm thick TF quality expanded polystyrene of 24 kg/cum density covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 26G aluminium sheet cladding complete with vent and outlets for system connection with float valave and drain valve.

-

-

-

... More
500X500X500 mm

2

-

-

... More
FLEXIBLE CONNECTIONS

-

-

-

... More
SITC of flexible conncetor as pump's pipe diameter suitable for PN 16 pressure rating to be installed at pump and Chiller's suction and discharge.

6

-

-

... More
FLOW SWITCH

-

-

-

... More
SITC of Flow switch with accessories as required.

2

-

-

... More
ELECTRICAL PANELS

-

-

-

... More
SITC of electrical panel as per CPRI standard and as specified in technical specifications. Panel shall be fabricated out of 14 gauge CRCA sheet steel with necessary structural supports in form of structural steel sections. Panel shall be floor mounted with IP 52 protection. Top bus duct/ cable entry and exit. The panel shall be compartmental, with suitable size of bus bar and sepearte cable/busbar chambers. Panel shall be treated with 7 tank process and 2 times epoxy painted. Proper gland size holes to be provided with proper sticker and danger sign on all sides of panel. Stardelta starter set with bypass switch to be provided for all pumps also. The cable chambers shall be free from any live open connections and minimum clearance to be provided. for terminations. earthing terminal to be provided along with panel which shall be 1 MTR wide of panel length. Proper ventillation to be provided with fans. Technical break up of each panel to be submitted along with TECHNICAL BID.

-

-

-

... More
1. Panel no. 01 - for 03 nos chilled water pumps and one spare with separate MCBs for all pumps and with switch gear for 12 KW electrical load. Switch gear make: L&T/Siemens/ABB. QTY: 01 Nos. 2. SITC of moulded case circuit breaker complete with its enclosure/MS powder coated box having size suitable for in&out cable termination, 3 pole + neutral link + phase barrier + spreader terminal, 50 KA rating suitable for 35 TR chiller. Having Switchgear make: L&T/Siemense/ABB. QTY: 02 Nos. 3. SITC of starter panel with all required electrical accessories having 02 nos MCBs + 01 nos spare suitable for AHU operations of 15 KW. QTY: 02 Nos.

1

-

-

... More
AIR HANDLING UNITS

-

-

-

... More
SITC of double decker type AHU having double skin panels with injected PUF insulation inside it. AHU shall have inbuilt heat recovery wheel feature, with same manufacturer as AHU having Eurovent/AHRI certification. Manufacturer shall have 10 plus years experience of designing and manufacturing in product i.e. energy recovery devices, with two side air flow having double decker construction in India. Manufacturer shall have facility to manufacture HRW and AHU body under his own roof in India. Capacity and Static pressure shall be as mentioned in BOQ. Frame of unit shall be made up of extruded Aluminium profile with thermal break property and without any welded joints. Following parameters can be considered while quoting: 1) An AHRI 1350 certified casing shall be used. 2) Deflection class shall be minimum CD4 3) Leakage class shall be minimum CL4 4) Thermal transmittance shall be minimum CT3 5) Thermal bridging shall be minimum CB3 Make: Systemair, Stulz, Trane, DRI, Flaktwood

-

-

-

... More
Programmable EC fans which can be operated as per varying load shall be prefered. AMCA certified fan performance will be considered for installation. Fan motor shall be energy efficient and suitable for 415+/-10% volts, 50 cycles, 3 phase squirrel cage with IP 55 protection. Motor shall be designed for quiet operation. Synthetic pre filter for class EU3 and washable synthetic non-woven media fine filters (microvee filters) for class F7 will be prefered. Rail provision to be made on filter frame to remove the filter by easy sliding and efficient gaskets to be provided for minimum leakages. Cooling coil with extended inlet outlet connections of desired dew point having AHRI certification will be prefered. Cooling coil shall mounted on SS drain pan having thickness of atleast 20 gauge with 25 mm closed cell nitrile rubber insulation. Mixing section of AHU shall be made up of built in dampers having plastic gear wheels and silicon gaskets provided between blades. HRW with minimum recovery of 75% of total heat, made up of pure aluminium foil. HRW effectiveness shall be considered as per AHRI 1060.

-

-

-

... More
Safety standards: UL 1995, CSA C 22.2 No. 236-11, heating and cooling equipment. HRW media certification: DIN EN ISO 846 Rotor requirements: ROHS Annex ll of 2011/65/eu and Amendment (EU) 2015/863. HRW manufacturer shall have able to show design performance in their own lab or test facility. facility should have provisions to show various test points such as temperature & RH of fresh/supply and exhaust/return air, air quantity during change in ambient conditions for factory inspection. The heat whell media shall confirms to flame spread index 0 and smoke developed index 0 in accordance to ASTM E84-13A test for surface burning characteristics or test method published in NFPA 255, UL 723 & UBC 8-1.

-

-

-

... More
12000 CFM, ( 65 mm St. Pr, 6 Row CC )

1

-

-

... More
12000 CFM, ( 65 mm St. Pr, 6 Row CC )

1

-

-

... More
INLINE FAN ( FOR TOILET Exhaust Air for COMMON TOILET Areas)

-

-

-

... More
Supply, installation, testing and commissioning of Round / Cabinet type rectangular Inline fans with motor complete motor complete with TEFC Sq. Cage Induction motor suitable for 220 volts ± 10%, 50Hz ± 3 %, single phase A.C supply of class "F" insulation with , mountings accessories in all respect with wiring upto power supply point & of following capacities as per specification and tender drawing mentioned.

-

-

-

... More
1000 cfm / 25mm St.Pr.

1

-

-

... More
900 cfm / 25mm St.Pr.

1

-

-

... More
700 cfm / 25mm St.Pr.

1

-

-

... More
PLUMBING

-

-

-

... More
G.I Condensate Drain Piping

-

-

-

... More
Supplying, fixing, testing and commissioning of condensate drain water piping of GI "Medium" Class complete with fittings like elbows, tees, reducers, bends, MS Flanges, supports, welding, painting etc. as required & conforming to tender specifications and of following sizes, Drain pipe shall be duly insulated with 15 mm thick polyurethen foam insulation at the joints etc. as per specifications & as required

-

-

-

... More
40 mm dia NB

10

-

-

... More
50 mm dia NB

10

-

-

... More
UPVC Condensate Drain Piping

-

-

-

... More
Supply, installation, testing and commissioning of drain piping of hard UPVC pipe and fittings, insulated with 12 mm thick nitrile rubber.

-

-

-

6

-

-

6

-

-

5

-

-

... More
Supplying & fixing of 18 G thick Aluminium extruded powder coated Fresh / Exhaust air weather protected louvers with bird screen type (with Aluminium frames if required) for ventilation with 12G GI wire mesh as per specification and sizes will be as per tender drawing mentioned.

0.9

-

-

... More
ELECTRICAL WORKS

-

-

-

... More
POWER & CONTROL CABLING

-

-

-

... More
Supplying, laying, effecting proper termination, testing & commissioning of the following FRLS POWER CABLE sizes of 1.1 KV - PVC inner sheated,extruded PVC type ST2 sheathed & Galvanised steel strips/wire as per IS 7908 (Part-I) armoured aluminium conductor cables conforming to relevant latest amended Indian Standardsas per specification standard.

-

-

-

... More
4 C - 16 sqmm (COPPER - PVC - ARMOURED)

60

-

-

... More
4 C - 25 sqmm (COPPER - PVC - ARMOURED)

5

-

-

... More
4 C - 35 sqmm (COPPER - PVC - ARMOURED)

5

-

-

... More
3C x 6 Sq. mm

-

-

-

... More
3C x 4 Sq. mm

60

-

-

... More
Earthing Strip / Wires.

-

-

-

... More
Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring / cable as required

120

-

-

... More
Providing and fixing 10 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring / cable as required

85

-

-

... More
VAV BOX WORKS

-

-

-

... More
VAV BOX

-

-

-

... More
Supplying, installation,testing & commissioning of VAV BOX of suitable capacity and sizes with actuator & and damper along with cabling for interconnecting etc as required & as per standard, drawings&specifications:

-

-

-

... More
(0 - 4000 ) CFM

-

-

-

... More
(0 - 3000 ) CFM

-

-

-

... More
(0 - 2000 ) CFM

-

-

-

... More
(0 - 1500 ) CFM

6

-

-

... More
(0 - 1000 ) CFM

-

-

-

... More
(0 - 500 ) CFM

-

-

-

... More
SMOKE VENTILATION SYSTEM

-

-

-

... More
SMOKE VENTILATION

-

-

-

... More
FRESH AIR SUPPLY

-

-

-

... More
Supply, erection, testing and commissioning of ceiling hunged Tube Axial flow fans with adjustable pitch blade , MS casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 6 / 4 pole, three phase A.C supply of class "F" insulation and shall IE -3 with support, mountings with vibration isolator spring and fire rated canvas flexible connection etc. & of following capacity as per approved tender drawings.(Noise Level shall not be more than 90 DB at a distance of 3 metres).Note Fan shall be AMCA Certified.

-

-

-

... More
In Normal / Emergency Mode:

-

-

-

... More
Air Qty. = 9000 CFM

-

-

-

... More
Static Pressure = 30 mm Wg

-

-

-

... More
Motor = Not exceed 2.2 Kw.

1

-

-

... More
EXHAUST AIR

-

-

-

... More
Supply, erection, testing and commissioning of ceiling hunged Tube Axial flow fans with adjustable pitch blade , MS casing, cast aluminium alloy impeller complete with TEFC Sq. Cage Induction motor suitable for 415 volts ± 10%, 50Hz ± 3 %, 6 / 4 pole, three phase A.C supply of class "H" insulation and shall IE -3 with support, mountings with vibration isolator spring and fire rated canvas flexible connection etc. & of following capacity as per approved tender drawings.The fan shall be completely rated for fire @ 250°C for 2 Hours.(Noise Level shall not be more than 90 DB at a distance of 3 metres).Note Fan shall be AMCA Certified.

-

-

-

... More
In Normal / Emergency Mode:

-

-

-

... More
Air Qty. = 9000 CFM

-

-

-

... More
Static Pressure = 30 mm Wg

-

-

-

... More
Motor = Not exceed 2.2 Kw.

1

-

-

... More
SUB - PANELS FOR SMOKE VENTILATION

-

-

-

... More
Supply ,installation, testing and commissioning of Cubical wall mounted type switch board made of 2mm thick CRCA sheet as detailed below & conforming to the specifications.

-

-

-

... More
Note: The HVAC contractor shall provide fire shunt relay contact in his panel wherever necessary along with auto/manual mode selector switch in the outgoing feeder forAXIAL FLOW Fan to take fire input signal (Potential Free Contact).Cost shall be included in the panel price quoted by him.

-

-

-

... More
For Axial Fan WITH (5.0 HP Fan Motor)

-

-

-

... More
16A TPN MCB for 16 A WITH DOL Starter, overload relay, start / stop push buttons, phase indication lights with protection fuse, on / off / trip indication lights with protection fuse, ammeter ( 0-16 A) with single CT, single phase preventer. Auto Manual Selector switch. MCB shall be of 10KA

-

-

-

... More
Controls & interlocking accessories as required.

2

-

-

... More
POWER & CONTROL CABLING

-

-

-

... More
Supplying, laying, effecting proper termination, testing & commissioning of the following POWER CABLE sizes of 1.1 KV - PVC inner sheated,extruded PVC type ST2 sheathed & Galvanised steel strips/wire as per IS 7908 (Part-I) armoured aluminium conductor cables conforming to relevant latest amended Indian Standardsas per specification standard.

-

-

-

... More
3C x 4 Sq. mm

40

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.