Public Works Roads Department Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Public Works Roads Department - PWRD Tender

Civil And Construction
Civil Works Roads
Road Construction
Eprocure
Opening Date1 Mar 2022
Closing Date8 Apr 2022
Tender Amount₹ 2,06,47,00,000 
Notes
Download

Costs

Summary

Improvement And Upgradation Of Rowta To Missamari Road

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lead and lifts and earth/sand filling in the depression/pit created as per Technical specifications Clause No.201) d) Girth above 1800 mm

2

-

-

... More
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical specifications Clause No.201 Girth from 300 mm to 600 mm

126

-

-

... More
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical specifications Clause No.201 Girth from 600 mm to 900 mm

101

-

-

... More
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical specifications Clause No.201 Girth from 900 mm to 1800 mm

75

-

-

... More
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical specifications Clause No.201 Girth above 1800 mm

50

-

-

... More
Clearing and Grubbing Road Land. Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of roots of trees cut earlier and disposal of unserviceable materials, stacking of serviceable material to be used as directed by Engineer as per technical specification Clause No.201)

59.22

-

-

... More
Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials to shown location, stacking serviceable and unserviceable materials separately, By mechanical means as per drawing or Technical specification clause No 202.) Bituminous courses

1174.47

-

-

... More
Dismantling of Flexible Pavements (Dismantling of flexible pavements and taking dismantled materials to construction camp, stacking serviceable and unserviceable materials separately for re-use as per drawing or additional Technical specification A-3, By mechanical means.as per drawing and technical specification) Granular courses

2566.38

-

-

... More
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, prestressed concrete, wood work, steel work, including Pools and plants (T&P) and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lift and lead.) Cement Concrete (RCC Above M-20)

137.28

-

-

... More
Excavation in Soil using Hydraulic Excavator Tippers with disposal all lead and lifts. (Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, loading disposal of excavated earth with in all lifts and leads or for reuse if suitable for embankment/subgrade at other location). As per Clause.301.3 technical specification)

1089.7

-

-

... More
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers within all lifts and leads. (Excavation for roadway in ordinary rock with hydraulic excavator including cutting and loading in tippers, transporting to embankment site within all lift and lead, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections as per technical specification Clause .301.3)

11.12

-

-

... More
Excavation in Marshy Soil (Excavation for roadway in marshy soil with hydraulic excavator including cutting and loading in tippers and disposal with in all lifts and lead, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections, as per technical specification Clause .301.3)

11.12

-

-

... More
Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirements of Technical specifications Clause No.305

1134529.76

-

-

... More
Construction of Embankment with materials deposited from roadway cutting (Construction of embankment with approved Material Deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2 and as per technical specification Clause 305).

889.55

-

-

... More
Construction of Subgrade/Median/Earthen Shoulders (Construction of sub-grade, Median and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 and Technical specification Clause 305 and 408)

182303.56

-

-

... More
Granular Sub-Base with Coarse Graded Material (Table: - 400- 1), (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical specifications clause 401) (I) For Grading V Material

55967.09

-

-

... More
Granular Sub-Base by reuse of excavated Coarse Graded Material from existing road (Table:- 400- 1) ( Construction of granular sub-base by reuse of excavated non bituminous base and sub base roadway material from existing road , taking to plant area ,crushing to size and mixing suitable materials required to bring it to desired grading latter spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 and Table 400-2 of Technical Specification and clause No. 401) (i)For Grading V Material

1539.83

-

-

... More
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate as per Technical specification including premixing the Material with water at OMC in mechanical mix plant, carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.as per Technical specification clause No.406)

56417.03

-

-

... More
Prime Coat Providing and applying primer coat as per Technical specification clause 502 with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per spreading rate approved by Engineer.

216715.31

-

-

... More
Tack Coat Providing and applying tack coat with bitumen emulsion as per Technical specifications clause 503 by using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom at rate of spread approved by Engineer.

216715.31

-

-

... More
Dense Bituminous Macadam Providing and laying dense bituminous macadam Grading II (19mm nominal aggregate size) using VG 30 grade bitumen with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade and alignment, compacting to achieve the desired compaction and complete in all respects as per Technical specification clause .505 .

15684.45

-

-

... More
Bituminous Concrete Providing and laying bituminous concrete Grading I (13mm nominal aggregate size) using PMB 70 grade bitumen with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, compacting to achieve the desired compaction and complete in all respects as per Technical specification clause 501.2 .1

8758.24

-

-

... More
Cast in Situ Cement Concrete M20 kerb with kerb laying machine, foundation concrete laid manually as per given drawing and Technical specifications Clause 409

835.97

-

-

... More
Cast in Situ Cement Concrete M20 kerb with Channel kerb laying machine, foundation concrete laid manually as per given drawing and Technical specifications Clause 410

1955

-

-

... More
Provision of Median kerb on road , constructed with with top and bottom width 100mm and 200 mm respectively, 850 mm high with M - 20 grade concrete, installed as per approved drawings and Technical specifications Clause 409 and at locations as directed by the Engineer.

1992

-

-

... More
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Technical specification clause no 801.3 90 cm equilateral triangle

73

-

-

... More
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Technical specification clause 801.3 60 cm equilateral triangle

73

-

-

... More
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and clause no. 801.3 60 cm circular

51

-

-

... More
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing 80 mm x 60 mm rectangular Clause No.801.3

7

-

-

... More
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and clause no 801.3 60 cm x 45 cm rectangular

7

-

-

... More
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and clause 801.3 60 cm x 60 cm square

7

-

-

... More
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectrorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Technical specification clause . 801.3 90 cm high octagon

9

-

-

... More
Direction and Place Identification Signs upto 0.9 Sqm Size Board. Providing and erecting direction and place identification retro-reflectrorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 Sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing and Technical specification clause 801.3

79.56

-

-

... More
Direction and Place Identification Signs with size more than 0.9 Sqm size Board. Providing and erecting direction and place identification retro- reflectrorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 Sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause No.801.3

28.5

-

-

... More
Kilometre Stone: Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc.as per technical specification IRC: 8 -1980 Type Designs of Highway Kilometre Stone (Second revision) 5th kilometre stone (precast)

4

-

-

... More
Kilometre Stone: Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc.as per technical specification IRC: 8 -1980 Type Designs of Highway Kilometre Stone (Second revision) Ordinary Kilometre stone (Precast)

15

-

-

... More
Kilometre Stone: Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc.as per technical specification IRC: 8 -1980 Type Designs of Highway Kilometre Stone (Second revision) Hectometre stone (Precast

75

-

-

... More
Overhead Signs of including Truss, Two Vertical Post, concrete foundation all complete Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectrorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in Technical specification clause 802.2 and 802.3 and installed as per Technical specification clause 802.6 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved drawing and plans and Technical specifications complete and Technical specification Clause No.802

1

-

-

... More
Metal Beam Crash Barrier Type - A, “W” : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2 m high with 1.15 m below ground level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS : 1367 and IS : 1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x5 mm, 546 mm long complete as per Technical specification clause 811.3 complete job as per approved drawings.

3537.68

-

-

... More
Flexible Crash Barrier, Wire Rope Safety Barrier (Providing and erecting a wire rope safety barrier with vertical posts of medium weight RS Joist (ISMB series) 100 mm x 75 mm (11.50 kg/m), 1.50 m long 0.85 m above ground and 0.65 m below ground level, split at the bottom for better grip , embeded in M-15 grade cement concrete 450mm X 450mm X 450mm, 1.50m centre to centre with 4 horizontal steel wire rope 40mm dia and anchored at terminal posts 15m apart. Terminal posts to be embeded in M15 grade cement concrete foundation 2400 X 450 X 900mm (Depth), strengthen by a strut of Rs joists 100X75mm. 2m long at 450 inclination and a tie 100 X 8mm, 1.50m long at the bottom, all embeded in foundation concrete as per approved design and drawing rate excluding excavation and cement concrete.) as per clause no 811.4

646.32

-

-

... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including Reflectorising glass beads @ 250 gms per Sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes as per Technical specification Clause No. 803.4

7970.45

-

-

... More
Boundary pillar Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25-1967, fixed in position including finishing and lettering but excluding painting as per Clause No. 807

180

-

-

... More
Cable Duct Across the Road Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC 98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC 98 - 2011 and approved drawings, Single Row for one utility service

100

-

-

... More
Road Stud with Lense Reflector Road Markers/Road Stud with Lense Reflector (Providing and fixing of road stud 100x 100 mm, die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973) and Technical specification Clause 804.

5034

-

-

... More
Supply & installation of solar street light proposed at Major & Minor Junction Location, Bus Bay & Bus Shelter Location as per drawing and Clause No. 12.4 of IRC SP 73 :2018 "Manual of Specifications and Standards for Two Laning of Highways with Paved Shoulder (Second Revision)

16

-

-

... More
Painting two coats after filling the surface with synthetic enamel paint in all shades on new concrete surfaces as per ATS-2

2191.74

-

-

... More
Construction of R.C.C Bus shelter at Village Portion as per drawing and Technical specifications Clause No. 12.6 of IRC SP 73 :2018 "Manual of Specifications and Standards for Two Laning of Highways with Paved Shoulder (Second Revision)

4

-

-

... More
Supply and Installation of 300 mm Solar Blinker. LED - 216 Solar Panel 30 Watt Battery - 12 AH Fitting, Fixing and all complete Job.

6

-

-

... More
Protection works Providing and laying Stone/Boulder Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specification Section 2500

62.9

-

-

... More
Protection works Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification 2501

193.75

-

-

... More
Protection works Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification and Section 2500

27.79

-

-

... More
Protection works Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification Clause No.2100 including steel shuttering formwork. For Chute Drain

495.5

-

-

... More
Protection works Gabion Structure for Erosion Control, River Training Works and Protection works (Providing and constructing gabion structures for erosion control, river training works and protection works with wire crates of size 2 m x 1 m x 0.3 m each divided into 1m compartments by cross netting, made from 4 mm galvanised steel wire@ 32Kgs per 10Sqm having minimum tensile strength of 300Mpa conforming to IS:280 and galvanizing coating conforming to IS:4826, woven into meshes with double twist, mesh size not exceeding to 100mmX100mm , filled with boulders at least dimension of 200mm , all loose ends to be tied with 4mm galvanized steel wire.) as per IRC SP 116:2018 Guidelines for Design and Installation of Gabion Structures

829.61

-

-

... More
Protection works Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surfaces behind the abutment, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification Section 2500 Retaining Wall

190.5

-

-

... More
Protection works Turfing with Sods (Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the engineer including preparation of ground, fetching of rods and watering) as per Technical specification Clause 307.

14085.3

-

-

... More
Protection works Supplying, filling and laying in loose with Geotextile bags of Type-A (1.30x0.70 M) made of Geo textile non-woven fabric sheets of 400 GSM manufactured from polyester/ polypropylene conforming to relevant ISO standard filled with specified sand/ silt from flood plain or adjacent char within a distance of 90 m of the work site including excavation, filling Geo bags with sand weighing 126.00 kg after filling, stitching the mouth of the filled bags with polypropylene or polyester complete as per technical specifications and as directed. as per IRC SP 59 :2019 Guidelines for use of Geosynthetics in Road Pavements and Associated Works

43138

-

-

... More
Protection works Supply, Stitching and Laying of Non-woven Geo textile Fabric sheet of 400 gsm as per Clause No 702

14547.12

-

-

... More
Box Culvert Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification Clause No 304, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

20360.72

-

-

... More
Box Culvert Plain/Reinforced cement concrete, in foundation complete as per drawing and technical specification including steel shuttering formwork and Technical specification Section 2100 RCC Grade M30 Using Batching Plant, Transit Mixer and Concrete Pump

951.07

-

-

... More
Box Culvert Reinforced cement concrete, in sub structure complete as per drawing and technical specification Section.2200 and steel shuttering formwork RCC Grade M30 Using Batching Plant, Transit Mixer and Concrete Pump

3984.14

-

-

... More
Box Culvert Furnishing and Placing Reinforced/ Prestressed cement concrete in superstructure as per drawing and Technical Specification’ Section 2300 including steel shuttering formwork. RCC Grade M30 Using Batching Plant, Transit Mixer and Concrete Pump

766.01

-

-

... More
Box Culvert Reinforcement in Foundation (Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and Technical specifications Section 1600)

76.09

-

-

... More
Box Culvert Reinforcement in Sub Structure (Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in sub structure complete as per drawing and Technical specifications Section 1600)

318.73

-

-

... More
Box Culvert Reinforcement in Super Structure Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D (reinforcement in super-structure including splicing complete as per drawing and technical specification Section 1600)

74.4

-

-

... More
Box Culvert Plain cement concrete, in foundation complete as per drawing and Technical specification section 2100 including steel shuttering formwork. PCC Grade M15

1583.42

-

-

... More
Box Culvert Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surfaces behind the abutment, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification Section 2500

2305.1

-

-

... More
Box Culvert Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification Clause 2706

4814

-

-

... More
Box Culvert Backfilling behind abutment, wing wall and return wall complete as per drawings and Technical Specification as Per clause 305

1748.71

-

-

... More
Box Culvert Stone/Boulder Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification Section 2500

874.36

-

-

... More
Box Culvert Plain cement concrete, in foundation complete as per drawing and Technical specification 2507 including steel shuttering formwork. Curtain wall/flexible Apron PCC Grade M20

1545.54

-

-

... More
Box Culvert Providing and laying Stone/Boulder Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications Section 2500

1748.71

-

-

... More
Box Culvert Providing and laying Stone/Boulder apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification Section 2500

3100.28

-

-

... More
Box Culvert Rigid Apron: -Providing and laying Flooring complete as per drawing and Technical specifications Section 2500 laid over cement concrete bedding. Rubble stone laid in cement mortar 1:3

1507.82

-

-

... More
Box Culvert Provision of reinforced cement concrete crash barrier (New Jersey Type) on structure, constructed with M - 40 grade concrete with HYSD reinforcement conforming to IRC:21, including 50mm dia railing with fixtures and installed as per approved drawings and at locations as directed by the Engineer. As per Technical specification Clause 2703.3 and Clause 811.2 & Clause No. 109.6. of IRC: 5 -2015 Standard Specifications and Code of Practice for Road Bridges Section- I General Features of Design

918.6

-

-

... More
Box Culvert Mastic Asphalt (Providing and laying 25 mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-29( binder having penetration as (15+/- 5) at 25 deg. centigrade), prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing anti-skid surface with bitumen pre coated fine grained hard stone ships of 13.2mm nominal size at the rate of .005Cum per 10 Sqm. and at an approximate spacing of 10 cm centre to centre in both directions, pressed into surface when the temperature of surfaces not less than 1000C, protruding 1mm to 4mm over mastic surface, all complete as per Technical specification Clause 2702.

1648.83

-

-

... More
Box Culvert Bituminous Concrete Providing and laying bituminous concrete Grading I (13mm nominal aggregate size) using PMB 70 grade bitumen with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, compacting to achieve the desired compaction and complete in all respects as per Technical specification clause 501.2 .1

65.95

-

-

... More
Box Culvert Tack Coat Providing and applying tack coat with bitumen emulsion as per Technical specifications clause 503 by using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom at rate of spread approved by Engineer.

1648.83

-

-

... More
Box Culvert Painting Two Coats on New Concrete Surfaces Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces as per Technical specification as per ATS-2

4409.28

-

-

... More
Minor Bridge Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification clause 304, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) for ordinary soil

753.17

-

-

... More
Minor Bridge Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification clause 304, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material) upto required depth for marshy soil without Dewarting

83.69

-

-

... More
Minor Bridge Providing and constructing temporary island 16 m diametre for construction of well foundation above 3m dia. well. A) Assuming depth of water 1.0 m and height of island to be 1.25m.

2

-

-

... More
Minor Bridge Providing and constructing temporary island 16 m diametre for construction of well foundation above 3m dia. well. C) Providing and constructing one span service road to reach island location from one pier location to another pier location

45

-

-

... More
Minor Bridge Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification clause no 2100 including steel shuttering formwork.

28.04

-

-

... More
Minor Bridge Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. RCC - M35 For Foundation

120.6

-

-

... More
Minor Bridge Providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per drawing and technical specification clause 1204.

9.69

-

-

... More
Minor Bridge Plain/Reinforced Cement Concrete M30 Grade, in Well curb of Well Foundation complete as per Drawing and Technical Specification clause 1205 With Batching Plant, Transit Mixer and Concrete Pump

204.99

-

-

... More
Minor Bridge Plain/Reinforced Cement Concrete (PCC) M25 Grade , in Bottom Plug of Well Foundation complete as per Drawing and Technical Specification clause 1209 With Batching Plant, Transit Mixer and Concrete Pump

412.88

-

-

... More
Minor Bridge Plain/Reinforced Cement Concrete (PCC) M15 Grade, Intermediarte Plug of Well Foundation complete as per Drawing and Technical Specification clause 1211 & Section 1700 With Batching Plant, Transit Mixer and Concrete Pump

11.55

-

-

... More
Minor Bridge Sinking of 5 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Depth below bed level upto 3.0 M

24

-

-

... More
Minor Bridge Sinking of 5 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 3m upto 10m depth

56

-

-

... More
Minor Bridge Sinking of 5 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 10m upto 20m depth

71.5

-

-

... More
Minor Bridge Sinking of 5 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 20m upto 30m depth

31.97

-

-

... More
Minor Bridge Sinking of 5.5 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Depth below bed level upto 3.0 M

6

-

-

... More
Minor Bridge Sinking of 5.5 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 3m upto 10m depth

14

-

-

... More
Minor Bridge Sinking of 5.5 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 10m upto 20m depth

20

-

-

... More
Minor Bridge Sinking of 5.5 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 20m upto 30m depth

9.03

-

-

... More
Minor Bridge Sinking of 6 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Depth below bed level upto 3.0 M

12

-

-

... More
Minor Bridge Sinking of 6 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 3m upto 10m depth

28

-

-

... More
Minor Bridge Sinking of 6 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 10m upto 20m depth

40

-

-

... More
Minor Bridge Sinking of 6 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 20m upto 30m depth

20.3

-

-

... More
Minor Bridge Sinking of 6 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 30m upto 40m depth

8.4

-

-

... More
Minor Bridge Plain/Reinforced Cement Concrete M30 Grade, in Well Steining of Well Foundation complete as per Drawing and Technical Specification clause 1207 With Batching Plant, Transit Mixer and Concrete Pump

3560.94

-

-

... More
Minor Bridge Sand Filling in Wells complete as per Drawing and Technical Specification clause 1210

3115.28

-

-

... More
Minor Bridge Plain/Reinforced Cement Concrete (PCC) M15 Grade , in Top/ Intermediarte Plug of Well Foundation complete as per Drawing and Technical Specification clause 1211 & 1700 With Batching Plant, Transit Mixer and Concrete Pump

34.47

-

-

... More
Minor Bridge Water filling in wells complete as per drawing and technical specifications

52.11

-

-

... More
Minor Bridge Plain/Reinforced Cement Concrete M30 Grade , in Well cap of Well Foundation complete as per Drawing and Technical Specification clause 1212,1213 and 1700 using Batching Plant, Transit Mixer and Concrete Pump

569.87

-

-

... More
Minor Bridge Plain/reinforced cement concrete in substructure complete as per drawings and technical specifications section 2200 With Batching Plant, Transit Mixer and Concrete Pump R.C.C. grade M-35

1381.08

-

-

... More
Minor Bridge Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure including all lead and lifts as per drawing and Technical Specification Section 2300 Sesmic Arrester and Pedestail PSC Grade M-50, Using Batching plant

56.14

-

-

... More
Minor Bridge Providing Tar paper bearing including laying in proper position etc. completed

34.2

-

-

... More
Minor Bridge Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications clauses 2000 & 2200

2184000

-

-

... More
Minor Bridge Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure including all lead and lifts as per drawing and Technical Specification section 2300 Slab Grade M-50

579.68

-

-

... More
Minor Bridge Reinforced cement concrete, in super-structure complete as per drawing and technical specification clause no 2200 and steel shuttering formwork; RCC M-35 grade using batching plant and concrete pump.

451.49

-

-

... More
Minor Bridge Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification

168

-

-

... More
Minor Bridge PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification Clause No 2704

91.58

-

-

... More
Minor Bridge Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification Clause No 2704

194.7

-

-

... More
Minor Bridge Providing and laying of an strip seal expansion joint complete as per drawing and Technical specification for road & bridge works Clause No.2606

192

-

-

... More
Minor Bridge Drainage Spouts complete as per drawing and Technical specification Clause No.2705

151

-

-

... More
Minor Bridge Supplying, fitting and placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specification section 1600

286.4

-

-

... More
Minor Bridge Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specificationssection 1600

152.57

-

-

... More
Minor Bridge Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications Section 1600

155.62

-

-

... More
Minor Bridge High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specifications Section1800

19.92

-

-

... More
Minor Bridge RCC Crash Barrier including reinforcement complete as per drawing and Technical Specifications Clause No.2703.3 and Clause No.811.2 & Clause No. 109.6. of IRC : 5 -2015 Standard Specifications and Code of Practice for Road Bridges Section- I General Features of Design

416.4

-

-

... More
Minor Bridge Painting two coats after filling the surface with synthetic enamel paint in all shades on new concrete surfaces as per ATS-2

849.46

-

-

... More
Minor Bridge Mastic Asphalt (Providing and laying 25 mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-29( binder having penetration as (15+/- 5) at 25 deg. centigrade), prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing anti-skid surface with bitumen pre coated fine grained hard stone ships of 13.2mm nominal size at the rate of .005Cum per 10 Sqm. and at an approximate spacing of 10 cm centre to centre in both directions, pressed into surface when the temperature of surfaces not less than 1000C, protruding 1mm to 4mm over mastic surface, all complete as per Technical specification Clause No.516

2290.2

-

-

... More
Minor Bridge Bituminous Concrete Providing and laying bituminous concrete complete as per drawing and Technical Specifications Clause No.501.2.1 (i) with PMB-70 Grade Bitumen (i) for grading 2 (13.2mm nominal size)

91.61

-

-

... More
Minor Bridge Tack Coat Providing and applying tack coat with bitumen emulsion as per Technical specifications clause 503 by using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom at rate of spread approved by Engineer.

2290.2

-

-

... More
Minor Bridge Providing and laying of Filter media with granular materials/stone crushed aggregates behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification and Appendix 6 of IRC78 :2014 "Standard Specifications and Code of Practice for Road Bridges"

1398.58

-

-

... More
Minor Bridge Providing and laying Stone/boulder apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification Clause No.2503.2

1124.36

-

-

... More
Major Bridge Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification clause 304, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) for ordinary soil

1455.67

-

-

... More
Major Bridge Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification clause 304, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material) upto required depth for marshy soil with dewatering

161.74

-

-

... More
Major Bridge Providing and constructing temporary island 16 m diametre for construction of well foundation above 3m dia. well. A) Assuming depth of water 1.0 m and height of island to be 1.25m.

14

-

-

... More
Major Bridge Providing and constructing temporary island 16 m diametre for construction of well foundation above 3m dia. well. C) Providing and constructing one span service road to reach island location from one pier location to another pier location

657

-

-

... More
Major Bridge Providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per drawing and technical specification clause 1204.

19.49

-

-

... More
Major Bridge Plain/Reinforced Cement Concrete M30 Grade, in Well curb of Well Foundation complete as per Drawing and Technical Specification clause 1205 & Section 1700 With Batching Plant, Transit Mixer and Concrete Pump

724.75

-

-

... More
Major Bridge Plain/Reinforced Cement Concrete (PCC) M25 Grade , in Bottom Plug of Well Foundation complete as per Drawing and Technical Specification clause 1209 & Section 1700 With Batching Plant, Transit Mixer and Concrete Pump

1272.8

-

-

... More
Major Bridge Sinking of 6.0 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Depth below bed level upto 3.0 M

57

-

-

... More
Major Bridge Sinking of 6.0 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 3m upto 10m depth

133

-

-

... More
Major Bridge Sinking of 6.0 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 10m upto 20m depth

190

-

-

... More
Major Bridge Sinking of 6.0 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 20m upto 30m depth

189.53

-

-

... More
Major Bridge Sinking of 6.0 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 30m upto 40m depth

13.38

-

-

... More
Major Bridge Sinking of 7.5 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Depth below bed level upto 3.0 M

15

-

-

... More
Major Bridge Sinking of 7.5 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 3m upto 10m depth

35

-

-

... More
Major Bridge Sinking of 7.5 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 10m upto 20m depth

50

-

-

... More
Major Bridge Sinking of 7.5 m external diametre well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications.Clause No.1208.1 to Clause No.1208.7and Clause No.1208.9 to Clause No. 1208.11. Depth of sinking is reckoned from bed level. Beyond 20m upto 30m depth

22.68

-

-

... More
Major Bridge Plain/Reinforced Cement Concrete M30 Grade, in Well Steining of Well Foundation complete as per Drawing and Technical Specification clause 1207 & 1700 With Batching Plant, Transit Mixer and Concrete Pump

10888.58

-

-

... More
Major Bridge Sand Filling in Wells complete as per Drawing and Technical Specification clause 1210

6029.2

-

-

... More
Major Bridge Plain/Reinforced Cement Concrete (PCC) M15 Grade , in Top/ Intermediarte Plug of Well Foundation complete as per Drawing and Technical Specification clause 1211 & Section 1700 With Batching Plant, Transit Mixer and Concrete Pump

112.86

-

-

... More
Minor Bridge Water filling in wells complete as per drawing and technical specifications

2441.9

-

-

... More
Major Bridge Plain/Reinforced Cement Concrete M30 Grade , in Well cap of Well Foundation complete as per Drawing and Technical Specification clause 1212, 1213 & Section 1700 using Batching Plant, Transit Mixer and Concrete Pump

975.99

-

-

... More
Major Bridge Plain/reinforced cement concrete in substructure complete as per drawings and technical specifications section 2200 With Batching Plant, Transit Mixer and Concrete Pump R.C.C. grade M-35 All height

2251.94

-

-

... More
Major Bridge Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure including all lead and lifts as per drawing and Technical Specification Section 2300 Sesmic Arrester and Pedestail Grade M-50, Using Batching plant

200.77

-

-

... More
Major Bridge Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of Technical specifications complete including all accessories as per drawing and Technical Specifications.

94050

-

-

... More
Major Bridge Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure including all lead and lifts as per drawing and Technical Specification section 2300 PSC Grider Grade M-45 All height

3693.45

-

-

... More
Major Bridge Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure including all lead and lifts as per drawing and Technical Specification section 2300 PSC Grider Grade M-50 All height

435.09

-

-

... More
Major Bridge Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure including all lead and lifts as per drawing and Technical Specification section 2300 Slab Grade M-45, All height

2671.68

-

-

... More
Major Bridge Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure including all lead and lifts as per drawing and Technical Specification section 2300 Slab Grade M-50, All height

242.75

-

-

... More
Major Bridge PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification Clause No 2704

77.48

-

-

... More
Major Bridge Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification Clause No 2704

165.6

-

-

... More
Major Bridge Providing and laying of an strip seal expansion joint complete as per drawing and Technical specification for road & bridge works Clause No.2606

404

-

-

... More
Major Bridge Drainage Spouts complete as per drawing and Technical specification Clause No.2705

736

-

-

... More
Major Bridge Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification Clause 2706

64

-

-

... More
Major Bridge Supplying, fitting and placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specification section 1600

708.86

-

-

... More
Major Bridge Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications section 1600

295.86

-

-

... More
Major Bridge Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications Section 1600

1072.22

-

-

... More
Minor Bridge High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specifications Section1800

276.45

-

-

... More
Major Bridge RCC Crash Barrier including reinforcement complete as per drawing and Technical Specifications Clause No.2703.3 and Clause No.811.2 & Clause No. 109.6. of IRC : 5 -2015 Standard Specifications and Code of Practice for Road Bridges Section- I General Features of Design

1367.9

-

-

... More
Major Bridge Painting Two Coats oil base on New Concrete Surfaces’ Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces

2790.52

-

-

... More
Major Bridge Steel work riveted and / or bolted/ riveted in built up sections, framework including cutting, hoisting, fixing in position and applying a priming coat of red-lead paint up to 4.6 m height above plinth including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed

8.58

-

-

... More
Major Bridge Providing and fixing of HDPE pipes 90mm dia (for utility)

2320

-

-

... More
Major Bridge Providing and fixing of Galvanised MS flat clamp (c/c @10 m)

252

-

-

... More
Major Bridge Bituminous Concrete Providing and laying bituminous concrete complete as per drawing and Technical Specifications Clause No.501.2.1 (i) with PMB-70 Grade Bitumen (i) for grading 2 (13.2mm nominal size)

370.54

-

-

... More
Major Bridge Mastic Asphalt (Providing and laying 25 mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-29( binder having penetration as (15+/- 5) at 25 deg. centigrade), prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing anti-skid surface with bitumen pre coated fine grained hard stone ships of 13.2mm nominal size at the rate of .005Cum per 10 Sqm. and at an approximate spacing of 10 cm centre to centre in both directions, pressed into surface when the temperature of surfaces not less than 1000C, protruding 1mm to 4mm over mastic surface, all complete as per Technical specification Clause 2702.

9263.45

-

-

... More
Major Bridge Tack Coat Providing and applying tack coat with bitumen emulsion as per Technical specifications clause 503 by using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom at rate of spread approved by Engineer.

9263.45

-

-

... More
Major Bridge Providing and laying of Filter media with granular materials/stone crushed aggregates behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification and Appendix 6 of IRC78 :2014 "Standard Specifications and Code of Practice for Road Bridges"

6798.65

-

-

... More
Major Bridge Providing and laying Stone/Boulder Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications Section 2500

5160.1

-

-

... More
Major Bridge Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications

14623.63

-

-

... More
Environment Management Cost Ambient air quality monitoring along the project road for particulate matter (PM2.5 and PM10), sulphur dioxide (SO2), oxides of nitrogen (NOX); and carbon monoxides (CO) using standard analysis technique in accordance with the National Ambient Air Quality Standards formulated by MoEF&CC and the World Bank (IFC) Air Quality. Near all hot mix plant locations approved by the Engineer as per Technical specification clause 111

9

-

-

... More
Environment Management Cost Ambient air quality monitoring along the project road for particulate matter (PM2.5 and PM10), sulphur dioxide (SO2), oxides of nitrogen (NOX); and carbon monoxides (CO) using standard analysis technique in accordance with the National Ambient Air Quality Standards formulated by MoEF&CC and the World Bank (IFC) Air Quality. Construction sites near sensitive locations as per Technical specification clause 111

9

-

-

... More
Environment Management Cost Ambient air quality monitoring along the project road for particulate matter (PM2.5 and PM10), sulphur dioxide (SO2), oxides of nitrogen (NOX); and carbon monoxides (CO) using standard analysis technique in accordance with the National Ambient Air Quality Standards formulated by MoEF&CC and the World Bank (IFC) Air Quality. At 2 location during operation stage where monitoring had been done during construction stage as per Technical specification clause 111

6

-

-

... More
Environment Management Cost Sound Pressure Level (SPL) measurements along the project road using standard analysis technique in accordance with the National Ambient Air Quality Standards in respect of noise formulated by MoEF&CC and the World Bank (IFC) Air Quality. At equipment yards/ Hot mix plants/ Construction Camps as per Technical specification clause 111

9

-

-

... More
Environment Management Cost Sound Pressure Level (SPL) measurements along the project road using standard analysis technique in accordance with the National Ambient Air Quality Standards in respect of noise formulated by MoEF&CC and the World Bank (IFC) Air Quality. Near known nesting sites - as directed by the Engineer as per Technical specification clause 111

9

-

-

... More
Environment Management Cost Sound Pressure Level (SPL) measurements along the project road using standard analysis technique in accordance with the National Ambient Air Quality Standards in respect of noise formulated by MoEF&CC and the World Bank (IFC) Air Quality. During Operation Stage as directed by the Engineer as per Technical specification clause 111

6

-

-

... More
Environment Management Cost Water Quality Testing for parametres as per IS: 10500-2012 along the road in accordance with CPCB norms Surface Water Quality testing during Construction Stage as per Technical specification clause 111

9

-

-

... More
Environment Management Cost Water Quality Testing for parametres as per IS: 10500-2012 along the road in accordance with CPCB norms Discharge Water Quality testing during Operation Stage as per Technical specification clause 111

3

-

-

... More
Environment Management Cost Soil Quality Testing along the project road in accordance with CPCB norms During Construction stage at productive agricultural lands abutting traffic detours and traffic diversions, to be identified by the Engineer as per Technical specification clause 111

9

-

-

... More
Environment Management Cost Soil Quality Testing along the project road in accordance with CPCB norms During Operation stage at accident/spill locations involving bulk transport carrying hazardous material. as per Technical specification clause 111

3

-

-

... More
Environment Management Cost Turfing with Sods (Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the engineer including preparation of ground, fetching of rods and watering) 5 m width turfing on outer side of ponds located at chainage CH. 6+250 (R), 23+500 (L), 36+300 (L) as per Technical specification clause 111 and 307

3000

-

-

... More
Environment Management Cost Surface Drains in Soil (Construction of unlined surface drains of average cross-sectional area 0.40 Sqm in soil to specified lines, grades, levels and dimensions to the requirement of Technical specification clause 301 and 309. Excavated material to be used in embankment within a lead of 50m (Average lead 25m) Construction of surface drains on outer side of ponds

672.72

-

-

... More
Environment Management Cost Oil interceptors at parking/ servicing of construction vehicles as per Technical specification clause 111

1

-

-

... More
Environment Management Cost Provision of Noise barrier at sensitive areas like schools and hospitals. The noise barriers of hollow brick wall/ reinforced concrete panels with height of 3.5m. At School location

50

-

-

... More
Provisional Sum for Road Facilities and Amenities

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.