Public Works Roads Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Public Works Roads Department - PWRD Tender
Civil And Construction
Bridge Construction
Eprocure
Opening Date28 Oct 2023
Closing Date9 Nov 2023
Tender Amount₹ 2,35,92,500
Costs
EMD
₹ 4,71,850Document Cost
₹ 4,700Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_PWD_33321_19Bid Award Id
ViewTender No
CE/STBR/MMPNA/08/2022-23/1 Dated 28/09/2023Tender Authority
Public Works Roads Department ViewPurchaser Address
-Website
http://https://pwdroads.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Semi - Dense Bituminous Concrete: Providing and laying semi dense bituminous concrete with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 to 5% of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.508. complete in all respect. including carriage of mixed materials up to 10.0 Km initial lead from mixing plant ) (Including cost of testing of materials at site and laboratory as directed by the deptt.) I) With hydrated lime/ cement as filler (refer table 500-9 of MoSRT&H
specification) A) With 60/70 or VG-30 grade bitumen ii. for Grading II (10 mm nominal size)
19.25
-
-
... More
Metal Beam Crash Barrier, Type - A: "W" Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2m center to center, 1.8 m high, 1.1m below ground/road level, all steel parts and fitments to be galvanized by hot dip process, all fitting to conform to IS:1367 and IS:1364, metal beam rail to be fixedon the vertical post with a spacer of channel section 150mm x 75mm x 5mm, 330mm long complete as per clause 810.)
160
-
-
... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 i) 900mm equilateral triangle
8
-
-
... More
Providing and Erecting 2.00 metre high temporary barricading at site, each panel of size 2.50m x 2.00m made of 40 x 40 x 6mm angle iron or 50 x 50 x 3mm hollow MS tube posts / horizontal members / bracings covered with 1.63mm thick MS sheet. The sheet shal be fixed with 30 x 5mm MS flat by suitable welding/riveting. The panel shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC75 @ 5.70 kg/m. 50cm long shall be provided at the bottom having over shaped holes of size 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avid from overturning by providing 250mm long expension fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps,reflective signs, marking, flags, coution tape as directed by the Engineer-in-Charge. The barricading provoded shall be retained in position at site continously i/c shifting of barricading from one location to another location as many times as required during the executionof the entire work till its completion. Rate include its maintenance for demages, painting, all incidentals, labour materials, equipments and works required to execute the job. the barricading shall not be removed without prior approval of Engineer-in-Charge.
20
-
-
... More
Removing of dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
120
-
-
... More
Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) B. For RCC Railing
120
-
-
... More
Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
3023.45
-
-
... More
Providing and applying two coats of ready mix paint including primer coat of approved brand on steel surface after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701
3023.45
-
-
... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
3023.45
-
-
... More
Removal of existing cement concrete wearing coat including its disposal complete as per Technical Specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled marerials with all lifta and leads upto 1000. (Thickness 75mm)
720
-
-
... More
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
54
-
-
... More
Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.
720
-
-
... More
Bituminous wearing course: Providing and laying Bituminous wearing course comprising of tack coat with bitumen emulsion CSS-1h as per APWD SOR item no 5.2 & MOSRT&H Specification Nos 503 0.6mm thick mastic asphalt as per APWD SOR item no 14.5 & MOSRT&H Specification Nos 515 & 2702 and 2 layers of 25 mm thick Asphalt concrete including of close Graded Premix Surfacing (CGPS) materials with Type -a aggregate as per APWD SOR tem no 5.11 & MOSRT&H Specification Nos 512 including all lead and lift as directed.
720
-
-
... More
Replacement of Expension Joints complete as per drawings.
15
-
-
... More
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation).
15
-
-
... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 I. Stone/Boulder
148.95
-
-
... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
34.2
-
-
... More
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301
234.55
-
-
... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
55.67
-
-
... More
Laying brick soling layer on prepared sub-grade with brick on end edging according to lines, graded and cross-section shown on the drawing filling joints with sand and earth, spreading 25 mm thick layer of earth over brick soling, watering and rolliing the same with three wheel road roller 80-100 kN as per
Technical Specification Clause 412
42
-
-
... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 A. Crushed Stone I. PCC grade M20 (i) Nominal Mix. 1:2:4
6.3
-
-
... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 II. Coursed Rubble masonry (2nd sort) In 1:3 cement mortar
94.5
-
-
... More
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
93
-
-
... More
Br. NO. 28/1 Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. A. Private Land
217.98
-
-
... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. ii. For Grading II Material
108
-
-
... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. A.By Manual Means Grading II Using stone screening Type-B 11.2 mm for Gr.II
54
-
-
... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. A. By Manual Means Using stone screening Type-B 11.2 mm for Gr.III
54
-
-
... More
Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. a) Including Edge block/ Edge restraints
720
-
-
... More
Metal Beam Crash Barrier, Type - A: "W" Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2m center to center, 1.8 m high, 1.1m below ground/road level, all steel parts and fitments to be galvanized by hot dip process, all fitting to conform to IS:1367 and IS:1364, metal beam rail to be fixedon the vertical post with a spacer of channel section 150mm x 75mm x 5mm, 330mm long complete as per clause 810.)
130
-
-
... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 i) 900mm equilateral triangle
8
-
-
... More
Providing and Erecting 2.00 metre high temporary barricading at site, each panel of size 2.50m x 2.00m made of 40 x 40 x 6mm angle iron or 50 x 50 x 3mm hollow MS tube posts / horizontal members / bracings covered with 1.63mm thick MS sheet. The sheet shal be fixed with 30 x 5mm MS flat by suitable welding/riveting. The panel shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC75 @ 5.70 kg/m. 50cm long shall be provided at the bottom having over shaped holes of size 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avid from overturning by providing 250mm long expension fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps,reflective signs, marking, flags, coution tape as directed by the Engineer-in-Charge. The barricading provoded shall be retained in position at site continously i/c shifting of barricading from one location to another location as many times as required during the executionof the entire work till its completion. Rate include its maintenance for demages, painting, all incidentals, labour materials, equipments and works required to execute the job. the barricading shall not be removed without prior approval of Engineer-in-Charge.
20
-
-
... More
Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
331.82
-
-
... More
Providing and applying two coats of ready mix paint including primer coat of approved brand on steel surface after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701
331.82
-
-
... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
331.82
-
-
... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 I. Stone/Boulder
120
-
-
... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
24.75
-
-
... More
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301
344.2
-
-
... More
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I. Ordinary soil A. Manual Means (I) Without dewatering (i) upto 3 m depth
429.57
-
-
... More
Providing and Construction of Gabain structure for retaining earth with segments of wire crates of size 7 m x 3 m x 0.6 m each divided into 1.5 m compartments bycross netting, made from 4 mm galvanised sheet wire @ 32 kg per 10 sqm having minimum tensil strength of 300 Mpa conforming to IS:280 and galvanizing coating conforming to IS:4826, woven in to meshes with double twist, mesh size not exceeding to 100mx100m, firred with boulders at least dimension of 200mm, all loose end to be tied with 4mm galvanized steel wire.
193.72
-
-
... More
Br. No. 31/1 Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. A. Private Land
242.2
-
-
... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. ii. For Grading II Material
67.5
-
-
... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. A.By Manual Means Grading II Using stone screening Type-B 11.2 mm for Gr.II
33.75
-
-
... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. A. By Manual Means Using stone screening Type-B 11.2 mm for Gr.III
33.75
-
-
... More
Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. a) Including Edge block/ Edge restraints
450
-
-
... More
Metal Beam Crash Barrier, Type - A: "W" Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2m center to center, 1.8 m high, 1.1m below ground/road level, all steel parts and fitments to be galvanized by hot dip process, all fitting to conform to IS:1367 and IS:1364, metal beam rail to be fixedon the vertical post with a spacer of channel section 150mm x 75mm x 5mm, 330mm long complete as per clause 810.)
90
-
-
... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 i) 900mm equilateral triangle
8
-
-
... More
Providing and Erecting 2.00 metre high temporary barricading at site, each panel of size 2.50m x 2.00m made of 40 x 40 x 6mm angle iron or 50 x 50 x 3mm hollow MS tube posts / horizontal members / bracings covered with 1.63mm thick MS sheet. The sheet shal be fixed with 30 x 5mm MS flat by suitable welding/riveting. The panel shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC75 @ 5.70 kg/m. 50cm long shall be provided at the bottom having over shaped holes of size 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avid from overturning by providing 250mm long expension fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps,reflective signs, marking, flags, coution tape as directed by the Engineer-in-Charge. The barricading provoded shall be retained in position at site continously i/c shifting of barricading from one location to another location as many times as required during the executionof the entire work till its completion. Rate include its maintenance for demages, painting, all incidentals, labour materials, equipments and works required to execute the job. the barricading shall not be removed without prior approval of Engineer-in-Charge.
20
-
-
... More
Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
331.82
-
-
... More
Providing and applying two coats of ready mix paint including primer coat of approved brand on steel surface after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701
331.82
-
-
... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
331.82
-
-
... More
Removal of existing cement concrete wearing coat including its disposal complete as per Technical Specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled marerials with all lifta and leads upto 1000. (Thickness 75mm)
146.25
-
-
... More
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
10.97
-
-
... More
Removal of existing asphaltic wearing coat comprising of 50 mm thick asphaltic concrete laid over 12 mm thick mastic asphalt including disposal with all lift and lead upto 1000m.
146.25
-
-
... More
Bituminous wearing course: Providing and laying Bituminous wearing course comprising of tack coat with bitumen emulsion CSS-1h as per APWD SOR item no 5.2 & MOSRT&H Specification Nos 503 0.6mm thick mastic asphalt as per APWD SOR item no 14.5 & MOSRT&H Specification Nos 515 & 2702 and 2 layers of 25 mm thick Asphalt concrete including of close Graded Premix Surfacing (CGPS) materials with Type -a aggregate as per APWD SOR tem no 5.11 & MOSRT&H Specification Nos 512 including all lead and lift as directed.
146.25
-
-
... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 I. Stone/Boulder
78.3
-
-
... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
19.8
-
-
... More
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301
331
-
-
... More
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I. Ordinary soil A. Manual Means (I) Without dewatering (i) upto 3 m depth
296.26
-
-
... More
Providing and Construction of Gabain structure for retaining earth with segments of wire crates of size 7 m x 3 m x 0.6 m each divided into 1.5 m compartments bycross netting, made from 4 mm galvanised sheet wire @ 32 kg per 10 sqm having minimum tensil strength of 300 Mpa conforming to IS:280 and galvanizing coating conforming to IS:4826, woven in to meshes with double twist, mesh size not exceeding to 100mx100m, firred with boulders at least dimension of 200mm, all loose end to be tied with 4mm galvanized steel wire.
133.6
-
-
... More
Br. No. 109/1 Drainage Spouts complete as per drawing and Technical specification
17
-
-
... More
Structural steel Built-Up-Girder (BUG) (Providing and launching Steel Truss of Structural steel BUG Super Structure including painting complete as per as per drawing and technical specifications under
Section 1900 of MOST.)
1.07
-
-
... More
Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. A. For Plain surface
72
-
-
... More
Providing and applying two coats of ready mix paint including primer coat of approved brand on steel surface after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701
778.88
-
-
... More
Removing of dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
778.88
-
-
... More
Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
778.88
-
-
... More
Removal of existing cement concrete wearing coat including its disposal complete as per Technical Specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled marerials with all lifta and leads upto 1000. (Thickness 75mm)
240
-
-
... More
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
18
-
-
... More
Replacemnt of Expension Joints complete as per drawings
16
-
-
... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 I. Stone/Boulder
307.53
-
-
... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
614.68
-
-
... More
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301
60
-
-
... More
Br. No.118/1 Drainage Spouts complete as per drawing and Technical specification
20
-
-
... More
Structural steel Built-Up-Girder (BUG) (Providing and launching Steel Truss of Structural steel BUG Super Structure including painting complete as per as per drawing and technical specifications under
Section 1900 of MOST.)
0.89
-
-
... More
Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. A. For Plain surface
180
-
-
... More
Providing and applying two coats of ready mix paint including primer coat of approved brand on steel surface after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701
1711.2
-
-
... More
Removing of dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
1711.2
-
-
... More
Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
1711.2
-
-
... More
Removal of existing cement concrete wearing coat including its disposal complete as per Technical Specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled marerials with all lifta and leads upto 1000. (Thickness 75mm)
720
-
-
... More
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
54
-
-
... More
Replacemnt of Expension Joints complete as per drawings
24
-
-
... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 I. Stone/Boulder
592.8
-
-
... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
1185.08
-
-
... More
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301
240
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements