Public Works Roads Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Public Works Roads Department - PWRD Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Mar 2024
Closing Date8 Mar 2024
Tender Amount₹ 44,72,000
Costs
EMD
₹ 89,440Document Cost
₹ 1,342Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_36851_1Bid Award Id
ViewTender No
NGTRD/ CS-245 / SOPD (G) /2023-24/3495-ATender Authority
Public Works Roads Department ViewPurchaser Address
-Website
http://https://pwdroads.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recess medium class PVC conduit as required ii) 4x10 sq mm +2x6 Sqmm earth wire
600
-
1005
Rewiring for light point / fan point / exhaust fan point / call bell point (for door call bell only) with 1.5 Sq.mm FRLS PVC insulted copper conductor single core cable in surface / recessed medium class PVC conduit, with modular swith, modular plate, suitable GI box and earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc as required. Group C
644
-
894
Supplying and fixing the following sizes of medium class PVC conduit along with acessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. i) 25mm
4500
-
145
Supplying and fixing the following sizes of medium class PVC conduit along with acessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. ii) 32mm
2500
-
184
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including conections but excluding modular plate etc as required. i) 5/6amp Switch
1064
-
103
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including conections but excluding modular plate etc as required. ii) 15/16amps Switch
30
-
156
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including conections but excluding modular plate etc as required. iii) 3 Pin 5/6A socket outlet
420
-
122
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including conections but excluding modular plate etc as required. iv) 6 Pin 15/16A socket outlet
30
-
197
Supplying and fixing the following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required. i) 3 Module (100mmx75mm)
40
-
327
Supplying and fixing the following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required. ii) 4 Module (125mmx75mm)
30
-
343
Supplying and fixing the following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required. iii) 6 Module (200mmx75mm)
70
-
402
Supplying and fixing the following size / modules GI box along with modular base & cover plate for modular switches in recess etc as required. iv) 8 Module (125mmx125mm)
30
-
454
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc as required.i) 3 Module
40
-
151
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc as required.ii) 6 Module
70
-
182
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc as required.iii) 8 Module
30
-
211
Providing and fixing the following rating and breaking capactity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panle board including drilling holes in the cubicle panel, making connections etc as required. i) 200A, 36KA, FPMCCB
7
-
15206
Supplying and fixing following way, horizontal type three pole and neutral, steel sheet, MCB Distribution Board, 415V on surface / recess complete with tinned copper bus bar, neutral bus bar, earth bar din bar, interconnections, powder painted including earthing etc as required (But without MCB / MCCB/RCCB / Isolator) i) 6way (4+18) Double door
21
-
4974
Supplying and fixing following way, horizontal type three pole and neutral, steel sheet, MCB Distribution Board, 415V on surface / recess complete with tinned copper bus bar, neutral bus bar, earth bar din bar, interconnections, powder painted including earthing etc as required (But without MCB / MCCB/RCCB / Isolator) ii) 8way (4+24) Double door
7
-
5967
Supplying and fixing of following ways surface / recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel dust protected, duly powder painted inclusive of 200amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer) as required (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required) i) 8 way (4+24), Double door
7
-
10165
Supplying and fixing following rating, four pole, 415 volts, residual current circuit breaker, having a sensitivity current 20mA in the existing MCB DB complete with connections, testing and commissioning etc as required. i) 63A
28
-
2872
Supplying and fixing 5amps to 32 amps rating, 240/420 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. i) Single pole
150
-
256
Supplying and fixing 5amps to 32 amps rating, 240/420 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. i) Single pole and neutral
100
-
599
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc as required
6
-
13
Earthing with GI earth pipe 4.5meter long, 40mm dia including accessories and provising masonry enclosure with cover plate having locking arrangement and water pipe etc with charcoal / coke and salt as required
3
-
6855
Supplying and laying 6SWG GI wire at 0.50meter below ground level for conductor earth electrode including connection etmination with GI thimble etc as required
30
-
51
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required. Above 35 Sq.mm and upto 95 sq.mm (clamped with 25x3mm MS flat clamp)
200
-
130
Supplying of pole, 63 Ampere rating MCB with connections as necessary and as directed by the Deptt.
56
-
2733
Supplying of 4 core Aluminium unarmoured 50sq mm power cable
200
-
926
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements