Public Works Roads Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 2,00,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Summary
Construction Of Road Under Dilkush Tea Garden, Road Labour Line Road Tilabasti Pwd Road To Bagan Hospital Including 6m Span Culvert Under Ridf-xxx For The Year 2024-25.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_41113_7Tender No
T/CC/ETN/SIL/2024-25/468(T)Tender Authority
Public Works Roads Department ViewPurchaser Address
-Website
http://https://pwdroads.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Construction of granular sub-base by providing well graded material spreading in uniforms layers by tractor with grading attachment on prepared surface mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density complete as per Technical Specification Clause 401.
360.94
-
-
... More
Providing laying spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness hand packing rolling with three wheel 80-100 kN static roller in stages to proper grade and camber applying and brooming stone screening/binding materials to fill up the interstices of coarse aggregate watering and compacting to the required density Grading 3 as per Technical Specification Clause 405 . 3) WBM Grading -iii Using stone screening Type-B 11.2 mm for Gr.III (A) By Manual Means
216.56
-
-
... More
Providing & laying of Interlocking Concrete Block Pavement(M40) having thickness 80mm as per drawing and technical specification clause 1504.Complete including carriage (including Edge block/ Edge restraints)
2887.5
-
-
... More
Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soilto specified lines, grades, levels and imensions. Excavated material to be used inembankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical
Specification Clause 307. (A) Manual means.
500
-
-
... More
Providing and fixing of retro-reflectorised cautionary mandatory and informatory sign as per IRC:67 made if encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over alluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm 600 mm below grounded level as per drawings and Technical Specification Clause 801 600 mm equilateral triangle
1
-
-
... More
Providing and fixing of retro-reflectorised cautionary mandatory and informatory sign as per IRC:67 made if encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over alluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm 600 mm below grounded level as per drawings and Technical Specification Clause 801
600 mm circular
1
-
-
... More
Painting on Concrete/Steel Surfaces with Epoxy
Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701
300
-
-
... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1
-
-
... More
Construction of 600mm Dia H.P Culvert Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
21.26
-
-
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (B) With Natural Gravel (i)PCC -Grade M10 (1:3:6).
2.3
-
-
... More
Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i)
2.88
-
-
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (B) With natural Gravel III.P.C.C Grade M20.
Nominal mix 1:2:4 (Hand mixed)
18.85
-
-
... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (iii) 600 mm dia
15
-
-
... More
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
34.18
-
-
... More
Slab Culvert 6.00m Span
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil upto 3 m depth
279.67
-
-
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6 [Hand Mixing]
20.09
-
-
... More
Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203
PCC Grade M 20
Nominial mix (1:2:4)
146.85
-
-
... More
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204
PCC Grade M 20
Nominial mix (1:2:4)
144.61
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
46
-
-
... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. R.C.C grade M 20 For design mix RCC M 20
26.8
-
-
... More
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
19.35
-
-
... More
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From
Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in
substructrue complete as per drawings and technical specification Clauses
1002, 1005, 1010 & 1202
0.14
-
-
... More
Supplying, fitting and placing MS Bar (Fe-500) reinforcement bar (From
Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL)
in superstructure complete as per drawing and technical specifications
Clauses 1002, 1010 and 1202
2.31
-
-
... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
38.25
-
-
... More
Providing and laying curtain walls complete as per drawing and technical specification Clause 1304
Cement concrete grade M 10
2.2
-
-
... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling
42.37
-
-
... More
Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans, covered with sealant complete as per drawing and technical specifications
24
-
-
... More
Single bamboo palasiding / walling of whole 2nd class bamboo (Jati or Bethua) 75mm dia and closely packed & driven including fitting fixing with half bamboo kamis horizontally in three rows with cane or tying with wire
complete and struts 1.5 m apart longitudinally and providing brush wood as per drawing and technical specifications Clause 1302.5
Driven at least 900 mm below ground and 900 mm above ground on average
162
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements