Public Works Roads Department Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Public Works Roads Department - PWRD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date9 Jan 2025
Closing Date30 Jan 2025
Tender Amount₹ 39,24,54,000 
Notes
Download

Costs

Summary

Ob/dd-53/assam/makum/01 Construction Of Rob At Makum (near Railway Lc Gate

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Pile Load test on Single vertical pile in accordance with IS : 2911 (Part - IV) (a) Initial load test

750

-

-

... More
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103- 1999 C. RCC M 35 Case-II With Batching Plant, Transit Mixer and Concrete Pump

225.83

-

-

... More
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)

100.33

-

-

... More
Providing steel liner 8mm thick for pile including fabricating upto required length and setting out as per detailed drawing.

101.29

-

-

... More
Substructure: Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 F. RCC Grade M25 (a) Height upto 5m Case-II With Batching Plant, Transit Mixer and Concrete Pump for Stair Case

80.36

-

-

... More
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 F. RCC Grade M25 (b) Height 5m to 10m Case-II With Batching Plant, Transit Mixer and Concrete Pump for Stair Case

5.66

-

-

... More
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M35 (a) Height up to 5m Case-II With Batching Plant, Transit Mixer and Concrete Pump

62.83

-

-

... More
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M35 (b) Height 5m to 10m Case-II With Batching Plant, Transit Mixer and Concrete Pump

126.14

-

-

... More
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)

35.01

-

-

... More
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete asper drawing and approved technical specifications.

2700

-

-

... More
Superstructure: Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. PSC Grade M-45 (ii) for I-beam & Slab including launching of precast girders by launching truss upto 40m span (a) Height from 5m to 10m

118.11

-

-

... More
Reinforcement in Super Structure: Supplying, fitting and placing TMTconforming to IS:1786 Fe 500 D reinforcement in super-structureincluding splicing complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)

23.62

-

-

... More
Structural steel Built-Up-Girder (BUG) (Providing and launching Steel Truss of Structural steel BUG Super Structure including painting complete as per as per drawing and technical specifications under Section 1900 of MOST.)

168

-

-

... More
Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-40 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bar 25mm dia, 450mm long at expansion joints filled with pre moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circular No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

62.56

-

-

... More
Drainage Spouts complete as per drawing and Technical specification

14

-

-

... More
PVC Pipe 150mm Dia

154

-

-

... More
Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity

234.6

-

-

... More
Providing and applying tack coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503 (ii) Normal Bituminous surface

234.6

-

-

... More
Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification A. with 60/70 or VG-30 grade bitumen (ii) for Grading-II (13mm nominal size)

9.38

-

-

... More
Mastic Asphalt Providing and laying 25 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500- 29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515.

234.6

-

-

... More
Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70mm, complete as per approved drawings and standard specifications to be installed by the mnufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.

200.7

-

-

... More
Providing, fitting and fixing mild steel railing complete as per drawing and Technical Specification.

67.45

-

-

... More
Providing, fitting and fixing Hand railing including MS Plat Base Plat Pipe complete as per drawing and Technical Specification. Over crash barrier

62.56

-

-

... More
Painting on concrete surface(Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) A. Plain Surface for Crash Barrier

165.16

-

-

... More
VIADUCT: Foundation: Excavation for Structures Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I. Ordinary Soil B. Mechanical Means (I) Without Dewatering (i) upto 3m depth

3043.53

-

-

... More
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including shuttering formwork II) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 A. PCC Grade M15

84.13

-

-

... More
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 (Pile diameter-1200 mm)

2400

-

-

... More
Pile Load test on Single vertical pile in accordance with IS : 2911 (Part - IV) (a) Routine load test (2nos of Test)

900

-

-

... More
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including shuttering formwork. II. With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 E. RCC Grade M25 Case-II With Batching Plant, Transit Mixer and Concrete Pump (for Approach & Suspended Slab Wall)

25.92

-

-

... More
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103- 1999 C. RCC M 30 Case-II With Batching Plant, Transit Mixer and Concrete Pump

1279.02

-

-

... More
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)

596.82

-

-

... More
Providing steel liner 8mm thick for Pile including fabricating upto Required length and setting out as per detailed drawing.

233.56

-

-

... More
Substructure: Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M35 (a) Height upto 5m Case-II With Batching Plant, Transit Mixer and Concrete Pump

198.81

-

-

... More
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 H. RCC Grade M35 (b) Height 5m to 10m Case-II With Batching Plant, Transit Mixer and Concrete Pump

604.26

-

-

... More
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)

108.42

-

-

... More
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete asper drawing and approved technical specifications.

15600

-

-

... More
Superstructure: Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. PSC Grade M-45 (ii) for I-beam & Slab including launching of precast girders by launching truss upto 40m span (a) Height from 5m to 10m

3068.41

-

-

... More
Reinforcement in Super Structure: Supplying, fitting and placing TMTconforming to IS:1786 Fe 500 D reinforcement in super-structureincluding splicing complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)

524.42

-

-

... More
High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specifications

46.2

-

-

... More
Reinforced Cement Concrete Crash Barrier (Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-40 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bar 25mm dia, 450mm long at expansion joints filled with pre moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclouser to MOST circular No. RW/NH - 33022/1/94-DO III dated June 1994 as per dimension in the approved drawing and at locations directed by the engineer, all as specified.

644

-

-

... More
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.

62.56

-

-

... More
Reinforced cement concrete Approach slab (M35) including reinforcement and formwork complete as per drawing and Technical specification (a) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/SAIL/Esser Steel) Jindal panther steel/Shyam steel or equivalent

25.2

-

-

... More
Drainage Spouts complete as per drawing and Technical specification

126

-

-

... More
PVC Pipe 150mm Dia

1260

-

-

... More
Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity

2415

-

-

... More
Providing and applying tack coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503 (ii) Normal Bituminous surface

2415

-

-

... More
Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification A. with 60/70 or VG-30 grade bitumen (ii) for Grading-II (13mm nominal size)

96.6

-

-

... More
Mastic Asphalt Providing and laying 25 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500- 29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515.

2415

-

-

... More
Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70mm, complete as per approved drawings and standard specifications to be installed by the mnufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.

432

-

-

... More
Painting on concrete surface(Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) A. Plain Surface for Crash Barrier & Kerb

1964.76

-

-

... More
Painting on concrete surface(Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) B. RCC Railling

62.56

-

-

... More
REINFORCED EARTH STRUCTURES : Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. III. Earth work including excavation, backfilling, grading and compaction with selected backfill soil in layers in Reinforced Earth works as per Technical specification and drawings.

339.09

-

-

... More
Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. IV. Construction of PCC strips level footing (35cm x 15cm) in M-15 gradeconcrete complete as per technical specification and drawing.

655.25

-

-

... More
Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. I. 180 mm thick, M-35 grade RCC Facing elements of shape and size as per design and drawing with bearing pads, joint fillers, tie strips, fastener and all accessories and consumable complete.

3128.15

-

-

... More
Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. II. Assembling, joining and laying of reinforcing elements. B. With Reinforcing elements of Synthetic Geogrids

3128.15

-

-

... More
Back fill with granular material which is to be retained by the wall. Granular material will be as per Clause 3104 and Placement & Compaction as per Clause 3106.5 of specifications for Road & Bridge works of MORT&H. A. Granular material

14116.49

-

-

... More
Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. V. Providing 600mm drainage bay behind RE wall with compacted granular material as per technical specification and drawing.

1676.5

-

-

... More
Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. VI. Construction of crash barrier, parapet, coping beam with friction slab in M-30 grade concrete complete as per technical specification and drawing

607.25

-

-

... More
Sub Surface Drains with Perforated Pipe Construction of a narrow filter sub- surface drain consisting of porous or perforated pipe laid in narrow trench surrounded by a geotextile filter fabric, with a minimum of 450 mm overlap of fabric and installed as per clause 702.3 and 309.3.5 including excavation and backfilling .

607.25

-

-

... More
Reinforcement in Super Structure: Supplying, fitting and placing TMTconforming to IS:1786 Fe 500 D reinforcement in super-structureincluding splicing complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)

60.73

-

-

... More
Approaches : Construction of Subgrade and Earthen Shoulders (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2) (ii) From Govt land

1317.5

-

-

... More
Granular Sub-Base with Coarse Graded Material ( Table:- 400.1)Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (iii) for grading-III material

248

-

-

... More
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. ( including carriage up to initial lead of 5.0 km from quarry and carriage of mixed materials up to 10.0 Km initial lead from mixing plant )

581.25

-

-

... More
Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. B (ii). Medium porosity

2325

-

-

... More
Providing and applying tack coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503 (iii) (a) Normal Bituminous surface

4650

-

-

... More
Dense Graded Bituminous Macadam (Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.) (I) with 60/70 or VG-30 grade bitumen (ii) for Grading-II (19mm nominal size)

209.25

-

-

... More
Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification A. with 60/70 or VG-30 grade bitumen (ii) for Grading-II (13mm nominal size)

69.75

-

-

... More
Service Road : EARTHWORK EXCAVATION (Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m (including Royalty @ Rs. 30.00 per Cum but excluding watering, rolling & compaction)

4136.55

-

-

... More
Construction of Subgrade and Earthen Shoulders (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2) (ii) From Govt land

2726.25

-

-

... More
Granular Sub-Base with Coarse Graded Material ( Table:- 400.1)Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (iii) for grading-III material

1500

-

-

... More
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. ( including carriage up to initial lead of 5.0 km from quarry and carriage of mixed materials up to 10.0 Km initial lead from mixing plant )

1875

-

-

... More
Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. B (ii). Medium porosity

7775

-

-

... More
Tack coat (Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503) (iii) (a) Normal Bituminous surface

15275

-

-

... More
Dense Graded Bituminous Macadam (Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.) (I) with 60/70 or VG-30 grade bitumen (ii) for Grading-II (19mm nominal size)

643.5

-

-

... More
Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) with 60/70 or VG-30 grade bitumen (ii) for Grading-II (13mm nominal size)

214.5

-

-

... More
Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade , sloped towards the kerb, kerb stone with channel laid with kerb laying machine,foundation concrete manually all complete as per clause 408.) B. Using Concrete Batching and Mixing Plant

1250

-

-

... More
RCC Cover Drain : Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I. Ordinary Soil B. Mechanical Means (I) Without Dewatering (i) upto 3m depth

3187.5

-

-

... More
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification shuttering formwork. I. Without plasticiser A. PCC Grade M15

106.25

-

-

... More
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. E. RCC Grade M25 Case-II With Batching Plant, Transit Mixer and Concrete Pump

787.5

-

-

... More
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)

59.06

-

-

... More
TRAFFIC SIGNS, ROAD MARKING AND ROAD APPURTENANCES : Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) (i) 900mm equilateral triangle

15

-

-

... More
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) (ii) 600mm equilateral triangle

6

-

-

... More
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) (iii) 600mm circular

6

-

-

... More
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) (iv) 800mm x 600mm rectangular

4

-

-

... More
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) (v) 600mm x 450mm rectangular

2

-

-

... More
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) (vi) 600mm x 600mm square

2

-

-

... More
Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) (vii) 900mm high octagon

6

-

-

... More
Direction and Place Identification signs upto 0.9 sqm size board. (Providing and erecting direction and place identification retro-reflectorised sign asper IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing)

1.8

-

-

... More
Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro- reflectorised sign asper IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing)

1.2

-

-

... More
Painting Lines, Dashes, Arrows etc on Roads in Two Coats on New Work (Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control ) (i) Over 10 cm in width

372

-

-

... More
Road Delineators Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide stripes, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and confirming to IRC-79 and the drawings.

468

-

-

... More
Road Markers/Road Stud with Lense Reflector Providing and fixing of road stud 100x 100 mm, die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973

312

-

-

... More
Street Lighting (Providing and fixing lighting on bridges, mounted on steel hollow circular poles of standard specifications, 5 m high fixed on parapets with cement concrete, 20 m apart and fitted with sodium vapour lamp) (cement concrete to be measured and paid separately) (i) For fixing in foothpath

54

-

-

... More
Lighting on Bridge (Providing and fixing lighting on bridges, mounted on steel hollow circular poles of standard specifications, 5m high fixed on parapets with cement concrete, 20m apart and fitted with soudium vapour lamp)

8

-

-

... More
Proof checking : Carrying out of Proof Checking of all structural Design and Drawings by IIT Guwahati

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.