Public Works Roads Department Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Public Works Roads Department - PWRD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date6 Jan 2024
Closing Date17 Jan 2024
Tender Amount₹ 3,74,23,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II materials

703.5

-

2930

... More
WBM Grading 3-Using stone screening Type-B 11.2 mm for Gr.III: Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By mannual means

421.5

-

3463.95

... More
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per echnical specification clause 1504 including carriage. a) including Edge block/Edge restraints

5625

-

1161.08

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (ii) 600 mm equilateral triangle

4

-

3933.19

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (iii) 600 mm circular

4

-

5345.8

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (iv) 800mm x 600mm rectangular

4

-

7537.1

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

1

-

24844.87

... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications

300

-

566.13

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 ii) Ordinary Kilometer Stone (Precast)

2

-

2509.17

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 iii) 200 m stone (precast)

6

-

667.27

... More
Earth work in excavation for structures as per drawings and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead of 50m

87.97

-

127.69

... More
Filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9 (i) Sand filling

5.85

-

1644.26

... More
Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and Technical Specification Clause 802, 803,1202& 1203. A. With crushed stone , I. PCC Grade M10

5.74

-

6036.57

... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications Clauses 802,804,805,806,807,1202 and 1204. A. With crushed stone, III. RCC GRADE M20 (i) Height up to 5m

22.29

-

7480.6

... More
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202

1.9

-

63702.28

... More
Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications Clause 800 & 1206.3 A. With crushed stone :

1.41

-

14419.59

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

14

-

134.7

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 ii. Sandy Material

29.17

-

1822.69

... More
Providing and laying curtain walls complete as per drawing and technical specification Clause 1304 III.Cement concrete grade M10

6.75

-

5600.05

... More
Construction of flexible apron 1m thick comprising of loose stone boulders weighing less than 25kg beyond curtain wall. (iii) Cement Concrete Grade M10

25.5

-

5734.64

... More
Earth work in excavation of foundation of structures as per drawing and technical specifications clauses 305.1 including setting out,construction of shoring and bracing, removal of stumps and other deleterious .Ordinary Soil

78.73

-

127.69

... More
Providing concrete for Plain/reinforced concrete in open foundations complete as per drawing and Technical specifications Clause 802, 803, 1202, & 1203. (A) with Crushed Stone,(I) PCC Grade M-10, Nominal Mix

9.26

-

6036.57

... More
Providing concrete for Plain/reinforced concrete in open foundations complete as per drawing and Technical specifications Clause 802, 803, 1202, & 1203. (A) with Crushed Stone,II) PCC Grade M15, Nominal Mix

26.2

-

5894.19

... More
Providing concrete for Plain/reinforced concrete in open foundations complete as per drawing and Technical specifications Clause 802, 803, 1202, & 1203. (A) with Crushed StoneIII)RCC Grade M20, Nominal Mix

20.16

-

6664.29

... More
Plain/reinforced concrete in sub structure complete as per drawing and Technical specifications Clause 802, 804, 805, 806, 807, 1202, & 1204., (A) with crushed stone.(I) PCC Grade M15, Nominal Mix

11.24

-

6234.21

... More
Plain/reinforced concrete in sub structure complete as per drawing and Technical specifications Clause 802, 804, 805, 806, 807, 1202, & 1204., (A) with crushed stone.(II) RCC Grade M20, Nominal Mix

15

-

7048.83

... More
Providing and laying reinforced cement concrete in super structure as per drawing and Technical specifications Clauses 800, 1205.4 and 1205.5., (A) with crushed stone.I) RCC Grade M20, Nominal Mix, Height upto 5.00 mtr.

13.22

-

8160.44

... More
Supplying, fitting and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications clauses 1002, 1010 and 1202.

4.02

-

65217.95

... More
Providing weep holes in brick masonary, Plain/Reinforced concrete abutment, wing wall/return wall with 100mm dia AC pipe,extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.

20

-

134.7

... More
Backfilling behind abutment, wing wall and return wall complete as per drawing and Technical specification clause 1204.3.8

8.04

-

1487.19

... More
Providing and laying of dry rubble flooring complete as per drawings and technical specifications clause 1304.

13.05

-

2596.06

... More
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as pee drawing and technical specifications clauses 800, 900 and 1208.

12

-

2763.19

... More
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I. Ordinary soil - Upto 3m depth.

65.36

-

127.69

... More
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109

3.62

-

6036.57

... More
Bedding of pipe : Type B (First Class) Bedding - Laying (First Class) bedding on well compacted approved granular material as per Clause 1105

6.9

-

1558.04

... More
Brick Masonry Work in cement mortar in foundation of Head walls complete exculding pointing and plastering as per drawing and technical specification Clause 1109. (A) Brick Masonary in 1:4 cement mortar

33.52

-

7450.77

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 1000mm dia.

15

-

7787.85

... More
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification

55.26

-

146.41

... More
Utility Shifting

1.5

-

33900

... More
road from 2nd km of Sonamukhi Mayerchar road at Suapata Pt I to Kajaikata Pt I road Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth up to 300mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to be used or auctioned, up to a lead of 1000m including removal and disposal of top organic soil not exceeding 150mm in thickness as per Technical Specification Clause 201 i) By Manual Means A. In area of non-thorny jungle.

1

-

52995.08

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (I) Private Land

12847.55

-

258.21

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (I) Private Land

1690.34

-

339.68

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II materials

1045.87

-

2908.5

... More
WBM Grading 3-Using stone screening Type-B 11.2 mm for Gr.III: Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By mannual means

626.63

-

3439.53

... More
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per echnical specification clause 1504 including carriage. a) including Edge block/Edge restraints

8362.5

-

1161.08

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (ii) 600 mm equilateral triangle

4

-

3933.19

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (iii) 600 mm circular

4

-

5345.8

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 (iv) 800mm x 600mm rectangular

4

-

7537.1

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

1

-

24845.6

... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications

446

-

566.13

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 ii) Ordinary Kilometer Stone (Precast)

3

-

2509.17

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 iii) 200 m stone (precast)

9

-

667.27

... More
Earth work in excavation of foundation of structures as per drawing and technical specifications clauses 305.1 including setting out,construction of shoring and bracing, removal of stumps and other deleterious .Ordinary Soil

157.46

-

127.69

... More
Providing concrete for Plain/reinforced concrete in open foundations complete as per drawing and Technical specifications Clause 802, 803, 1202, & 1203. (A) with Crushed Stone,(I) PCC Grade M-10, Nominal Mix

18.52

-

6036.57

... More
Providing concrete for Plain/reinforced concrete in open foundations complete as per drawing and Technical specifications Clause 802, 803, 1202, & 1203. (A) with Crushed Stone,II) PCC Grade M15, Nominal Mix

52.4

-

5894.19

... More
Providing concrete for Plain/reinforced concrete in open foundations complete as per drawing and Technical specifications Clause 802, 803, 1202, & 1203. (A) with Crushed StoneIII)RCC Grade M20, Nominal Mix

40.32

-

6664.29

... More
Plain/reinforced concrete in sub structure complete as per drawing and Technical specifications Clause 802, 804, 805, 806, 807, 1202, & 1204., (A) with crushed stone.(I) PCC Grade M15, Nominal Mix

22.48

-

6234.21

... More
Plain/reinforced concrete in sub structure complete as per drawing and Technical specifications Clause 802, 804, 805, 806, 807, 1202, & 1204., (A) with crushed stone.(II) RCC Grade M20, Nominal Mix

30

-

7048.83

... More
Providing and laying reinforced cement concrete in super structure as per drawing and Technical specifications Clauses 800, 1205.4 and 1205.5., (A) with crushed stone.I) RCC Grade M20, Nominal Mix, Height upto 5.00 mtr.

26.44

-

8160.44

... More
Supplying, fitting and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications clauses 1002, 1010 and 1202.

8.04

-

65217.95

... More
Providing weep holes in brick masonary, Plain/Reinforced concrete abutment, wing wall/return wall with 100mm dia AC pipe,extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.

40

-

134.7

... More
Backfilling behind abutment, wing wall and return wall complete as per drawing and Technical specification clause 1204.3.8

16.08

-

1487.19

... More
Providing and laying of dry rubble flooring complete as per drawings and technical specifications clause 1304.

26.1

-

2596.06

... More
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as pee drawing and technical specifications clauses 800, 900 and 1208.

24

-

2763.19

... More
Construction of 1000mm dia single opening HPC Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I. Ordinary soil - Upto 3m depth.

98.04

-

127.69

... More
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109

5.43

-

6036.57

... More
Bedding of pipe : Type B (First Class) Bedding - Laying (First Class) bedding on well compacted approved granular material as per Clause 1105

10.35

-

1558.04

... More
Brick Masonry Work in cement mortar in foundation of Head walls complete exculding pointing and plastering as per drawing and technical specification Clause 1109. (A) Brick Masonary in 1:4 cement mortar

50.28

-

7450.77

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 1000mm dia.

22.5

-

7787.85

... More
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification

82.89

-

146.41

... More
Utility Shifting

2.23

-

33900



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.